{"lab":{"_id":"69ad52a3de79e566650fb5e0","accr_number":"AB 1152","country":"PL","accr_body":"PCA","address":"W IŁAWIE, ul. Sienkiewicza 10, 14-200 Iława","categories":["water","microbiology","environment"],"city":"Iława","imported_at":"2026-03-08T10:42:43.265Z","methods_count":17,"name":"POWIATOWA STACJA SANITARNO – EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1152.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno – epidemiologiczna w iławie, ul. sienkiewicza 10, 14-200 iława environment other metrology water pharma electronics microbiology automotive food","status":"active","updated_at":"2026-03-08T14:50:19.625Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:19.625Z","email_confidence":"high","email_mx":true,"email_source":"https://www.gov.pl/web/psse-ilawa/kontakt","parse_date":"2026-07-17T16:19:06.376Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/28; C/29/P","pl":"Badania chemiczne wody, wody do spożycia przez ludzi i pobieranie próbek wody do spożycia przez ludzi","en":"Chemical tests of water, drinking water and sampling of drinking water"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – oświetlenie, hałas, drgania)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – lighting, noise, vibration)"},{"codes":"K/3","pl":"Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań","en":"Microbiological tests of biological items and materials for testing"},{"codes":"K/28; K/29/P","pl":"Badania mikrobiologiczne wody, wody do spożycia przez ludzi i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests of water, drinking water and sampling of drinking water"},{"codes":"N/28; N/29/P","pl":"Badania właściwości fizycznych wody, wody do spożycia przez ludzi i pobieranie próbek wody do spożycia przez ludzi","en":"Tests of physical properties of water, drinking water and sampling of drinking water"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Sampling - working environment (harmful factors - air)"}],"issue":{"no":"23","date":"27.01.2026"},"map_coord":[53.59916,19.55199],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":11,"microbiology":8,"environment":4,"other":1},"category_scores":{"water":5.04,"microbiology":2.67,"environment":0.67,"other":0.04},"has_zh":true},"methods":[{"_id":"6a5a55fa9af9f73f382529bb","lab_id":"69ad52a3de79e566650fb5e0","country":"PL","accr_number":"AB 1152","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (44 – 135) dB Szczytowy poziom dźwięku C Zakres: (44 – 138) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level A-weighted maximum sound level Range: (44 – 135) dB C-weighted peak sound level Range: (44 – 138) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (44 – 135) dB Szczytowy poziom dźwięku C Zakres: (44 – 138) dB Metoda pomiarowa bezpośrednia","reference":"PN-EN-ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – p. 10 i 11 PN-N-01307:1994","norm_bases":["PN-EN-ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – p. 10 i 11 PN-N-01307:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Zakres: (44 – 135) dB Szczytowy poziom dźwięku C Zakres: (44 – 138) dB Metoda pomiarowa bezpośrednia PN-EN-ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – p. 10 i 11 PN-N-01307:1994 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Zakres: (44 – 135) dB Szczytowy poziom dzwieku C Zakres: (44 – 138) dB Metoda pomiarowa bezposrednia PN-EN-ISO 9612:2011 z wylaczeniem metod obejmujacych strategie 2 i 3 – p. 10 i 11 PN-N-01307:1994","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - noise A-weighted equivalent sound level A-weighted maximum sound level Range: (44 – 135) dB C-weighted peak sound level Range: (44 – 138) dB Direct measurement method PN-EN-ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – p. 10 i 11 PN-N-01307:1994","search_zh":"工作场所环境 — 噪声 PN-EN-ISO 9612:2011 z wyłączeniem metod obejmujących strategię 2 i 3 – p. 10 i 11 PN-N-01307:1994","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5a55fa9af9f73f382529bc","lab_id":"69ad52a3de79e566650fb5e0","country":"PL","accr_number":"AB 1152","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Poziom ekspozycji na hałas odniesiony do: -8-godz. dobowego wymiaru czasu pracy przeciętnego tygodniowego czasu pracy (z obliczeń)","methodology_en":"Noise exposure level normalised to: -an 8-hour working day an average weekly working time (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do: -8-godz. dobowego wymiaru czasu pracy przeciętnego tygodniowego czasu pracy (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do: -8-godz. dobowego wymiaru czasu pracy przeciętnego tygodniowego czasu pracy (z obliczeń) Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do: -8-godz. dobowego wymiaru czasu pracy przecietnego tygodniowego czasu pracy (z obliczen)","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - noise Noise exposure level normalised to: -an 8-hour working day an average weekly working time (calculated)","search_zh":"工作场所环境 — 噪声","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5a55fa9af9f73f382529bd","lab_id":"69ad52a3de79e566650fb5e0","country":"PL","accr_number":"AB 1152","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment - indoor electric lighting","methodology":"Natężenie oświetlenia Zakres: (20 – 5000) lx Metoda pomiarowa bezpośrednia","methodology_en":"Illuminance Range: (20 – 5000) lx Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie oświetlenia Zakres: (20 – 5000) lx Metoda pomiarowa bezpośrednia","reference":"PN-EN-83/E-04040.03 PB-SBŚP-03 edycja 4 z dnia 30.07.2024 r.","norm_bases":["PN-EN-83/E-04040.03 PB-SBŚP-03 edycja 4 z dnia 30.07.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia Zakres: (20 – 5000) lx Metoda pomiarowa bezpośrednia PN-EN-83/E-04040.03 PB-SBŚP-03 edycja 4 z dnia 30.07.2024 r. Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia Zakres: (20 – 5000) lx Metoda pomiarowa bezposrednia PN-EN-83/E-04040.03 PB-SBSP-03 edycja 4 z dnia 30.07.2024 r.","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - indoor electric lighting Illuminance Range: (20 – 5000) lx Direct measurement method PN-EN-83/E-04040.03 PB-SBŚP-03 edycja 4 z dnia 30.07.2024 r.","search_zh":"工作场所环境 — 室内电气照明 PN-EN-83/E-04040.03 PB-SBŚP-03 edycja 4 z dnia 30.07.2024 r.","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a5a55fa9af9f73f382529be","lab_id":"69ad52a3de79e566650fb5e0","country":"PL","accr_number":"AB 1152","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment - indoor electric lighting","methodology":"Równomierność oświetlenia (z obliczeń)","methodology_en":"Illuminance uniformity (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen)","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - indoor electric lighting Illuminance uniformity (calculated)","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值）","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a5a55fa9af9f73f382529bf","lab_id":"69ad52a3de79e566650fb5e0","country":"PL","accr_number":"AB 1152","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba bakterii grupy coli Metoda filtracji membranowej","methodology_en":"Coliform bacteria count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli Metoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12/A1:2017- 04","norm_bases":["PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12/A1:2017- 04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12/A1:2017- 04 Woda, woda do spozycia przez ludzi Liczba bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12/A1:2017- 04","categories":["water","microbiology"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12/A1:2017- 04","methodology_zh":"大肠菌群计数 膜过滤法","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 PN-EN ISO 9308-1:2014-12/A1:2017- 04","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55fa9af9f73f382529c0","lab_id":"69ad52a3de79e566650fb5e0","country":"PL","accr_number":"AB 1152","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba Escherichia coli Metoda filtracji membranowej","methodology_en":"Escherichia coli count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Escherichia coli Metoda filtracji membranowej","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba Escherichia coli Metoda filtracji membranowej Woda, woda do spozycia przez ludzi Liczba Escherichia coli Metoda filtracji membranowej","categories":["water","microbiology"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Escherichia coli count Membrane filtration method","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数 膜过滤法","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55fa9af9f73f382529c1","lab_id":"69ad52a3de79e566650fb5e0","country":"PL","accr_number":"AB 1152","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba enterokoków kałowych Metoda filtracji membranowej","methodology_en":"Intestinal enterococci count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych Metoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba enterokoków kałowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, woda do spozycia przez ludzi Liczba enterokokow kalowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水、生活饮用水 肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","test_object_zh":"水、生活饮用水","methodology_zh":"肠球菌计数 膜过滤法"},{"_id":"6a5a55fa9af9f73f382529c2","lab_id":"69ad52a3de79e566650fb5e0","country":"PL","accr_number":"AB 1152","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 22°C i 36°C Metoda płytkowa (posiew wgłębny)","methodology_en":"Total microorganism count at 22°C and 36°C Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22°C i 36°C Metoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22°C i 36°C Metoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22°C i 36°C Metoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Total microorganism count at 22°C and 36°C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水、生活饮用水 22°C 与 36°C 微生物总数 平板法（倾注平板） PN-EN ISO 6222:2004","test_object_zh":"水、生活饮用水","methodology_zh":"22°C 与 36°C 微生物总数 平板法（倾注平板）"},{"_id":"6a5a55fa9af9f73f382529c3","lab_id":"69ad52a3de79e566650fb5e0","country":"PL","accr_number":"AB 1152","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba Escherichia coli Najbardziej prawdopodobna liczba bakterii grupy coli Metoda NPL","methodology_en":"Most probable number of Escherichia coli Most probable number of coliform bacteria MPN method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli Najbardziej prawdopodobna liczba bakterii grupy coli Metoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba Escherichia coli Najbardziej prawdopodobna liczba bakterii grupy coli Metoda NPL PN-EN ISO 9308-2:2014-06 Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba Escherichia coli Najbardziej prawdopodobna liczba bakterii grupy coli Metoda NPL PN-EN ISO 9308-2:2014-06","categories":["microbiology","water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Most probable number of Escherichia coli Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06","search_zh":"水、生活饮用水 PN-EN ISO 9308-2:2014-06","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55fa9af9f73f382529c4","lab_id":"69ad52a3de79e566650fb5e0","country":"PL","accr_number":"AB 1152","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba bakterii z rodzaju Legionella Matryca A: Procedura 5 (podłoże A), Procedura 7 (podłoże C – GVPC) Metoda filtracji membranowej","methodology_en":"Count of bacteria of the genus Legionella Matrix A: Procedure 5 (medium A), Procedure 7 (medium C – GVPC) Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella Matryca A: Procedura 5 (podłoże A), Procedura 7 (podłoże C – GVPC) Metoda filtracji membranowej","reference":"PN-EN ISO 11731:2017- 08+Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017- 08+Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella Matryca A: Procedura 5 (podłoże A), Procedura 7 (podłoże C – GVPC) Metoda filtracji membranowej PN-EN ISO 11731:2017- 08+Ap1:2019-12 Woda, woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella Matryca A: Procedura 5 (podloze A), Procedura 7 (podloze C – GVPC) Metoda filtracji membranowej PN-EN ISO 11731:2017- 08+Ap1:2019-12","categories":["microbiology","water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Count of bacteria of the genus Legionella Matrix A: Procedure 5 (medium A), Procedure 7 (medium C – GVPC) Membrane filtration method PN-EN ISO 11731:2017- 08+Ap1:2019-12","search_zh":"水、生活饮用水 PN-EN ISO 11731:2017- 08+Ap1:2019-12","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55fa9af9f73f382529c5","lab_id":"69ad52a3de79e566650fb5e0","country":"PL","accr_number":"AB 1152","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba Pseudomonas aeruginosa Metoda filtracji membranowej","methodology_en":"Pseudomonas aeruginosa count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa Metoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba Pseudomonas aeruginosa Metoda filtracji membranowej PN-EN ISO 16266:2009 Woda na plywalniach Liczba Pseudomonas aeruginosa Metoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","search_zh":"游泳池水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","test_object_zh":"游泳池水","methodology_zh":"铜绿假单胞菌计数 膜过滤法"},{"_id":"6a5a55fa9af9f73f382529c6","lab_id":"69ad52a3de79e566650fb5e0","country":"PL","accr_number":"AB 1152","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba gronkowców koagulazododatnich Metoda filtracji membranowej","methodology_en":"Coagulase-positive staphylococci count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba gronkowców koagulazododatnich Metoda filtracji membranowej","reference":"PN-Z-11001-3:2000 Załącznik A","norm_bases":["PN-Z-11001-3:2000 Załącznik A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba gronkowców koagulazododatnich Metoda filtracji membranowej PN-Z-11001-3:2000 Załącznik A Woda na plywalniach Liczba gronkowcow koagulazododatnich Metoda filtracji membranowej PN-Z-11001-3:2000 Zalacznik A","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Swimming pool water Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3:2000 Załącznik A","search_zh":"游泳池水 凝固酶阳性葡萄球菌数 膜过滤法 PN-Z-11001-3:2000 Załącznik A","test_object_zh":"游泳池水","methodology_zh":"凝固酶阳性葡萄球菌数 膜过滤法"},{"_id":"6a5a55fa9af9f73f382529c7","lab_id":"69ad52a3de79e566650fb5e0","country":"PL","accr_number":"AB 1152","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba bakterii z rodzaju Legionella Matryca A: Procedura 5 (podłoże A), Procedura 7 (podłoże C – GVPC) Metoda filtracji membranowej","methodology_en":"Count of bacteria of the genus Legionella Matrix A: Procedure 5 (medium A), Procedure 7 (medium C – GVPC) Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella Matryca A: Procedura 5 (podłoże A), Procedura 7 (podłoże C – GVPC) Metoda filtracji membranowej","reference":"PN-EN ISO 11731:2017- 08+Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017- 08+Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba bakterii z rodzaju Legionella Matryca A: Procedura 5 (podłoże A), Procedura 7 (podłoże C – GVPC) Metoda filtracji membranowej PN-EN ISO 11731:2017- 08+Ap1:2019-12 Woda na plywalniach Liczba bakterii z rodzaju Legionella Matryca A: Procedura 5 (podloze A), Procedura 7 (podloze C – GVPC) Metoda filtracji membranowej PN-EN ISO 11731:2017- 08+Ap1:2019-12","categories":["microbiology","water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Swimming pool water Count of bacteria of the genus Legionella Matrix A: Procedure 5 (medium A), Procedure 7 (medium C – GVPC) Membrane filtration method PN-EN ISO 11731:2017- 08+Ap1:2019-12","search_zh":"游泳池水 PN-EN ISO 11731:2017- 08+Ap1:2019-12","test_object_zh":"游泳池水"},{"_id":"6a5a55fa9af9f73f382529c8","lab_id":"69ad52a3de79e566650fb5e0","country":"PL","accr_number":"AB 1152","accr_body":"PCA","test_object":"Woda przeznaczona do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda przeznaczona do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda przeznaczona do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水"},{"_id":"6a5a55fa9af9f73f382529c9","lab_id":"69ad52a3de79e566650fb5e0","country":"PL","accr_number":"AB 1152","accr_body":"PCA","test_object":"Woda z kąpielisk i miejsc wykorzystywanych do kąpieli","test_object_en":"Water from bathing waters and bathing places","methodology":"Najbardziej prawdopodobna liczba Escherichia coli Metoda zminiaturyzowana (NPL)","methodology_en":"Most probable number of Escherichia coli Miniaturised method (MPN)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli Metoda zminiaturyzowana (NPL)","reference":"PN-EN ISO 9308-3:2002","norm_bases":["PN-EN ISO 9308-3:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda z kąpielisk i miejsc wykorzystywanych do kąpieli Najbardziej prawdopodobna liczba Escherichia coli Metoda zminiaturyzowana (NPL) PN-EN ISO 9308-3:2002 Woda z kapielisk i miejsc wykorzystywanych do kapieli Najbardziej prawdopodobna liczba Escherichia coli Metoda zminiaturyzowana (NPL) PN-EN ISO 9308-3:2002","categories":["water","microbiology"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water from bathing waters and bathing places Most probable number of Escherichia coli Miniaturised method (MPN) PN-EN ISO 9308-3:2002","search_zh":"浴场水与用于游泳场所的水 大肠埃希氏菌最可能数 微量法（MPN） PN-EN ISO 9308-3:2002","test_object_zh":"浴场水与用于游泳场所的水","methodology_zh":"大肠埃希氏菌最可能数 微量法（MPN）"},{"_id":"6a5a55fa9af9f73f382529ca","lab_id":"69ad52a3de79e566650fb5e0","country":"PL","accr_number":"AB 1152","accr_body":"PCA","test_object":"Kał, wymaz z odbytu","test_object_en":"Faeces, rectal swab","methodology":"Obecność pałeczek Salmonella spp., Shigella spp. Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","methodology_en":"Presence of Salmonella spp., Shigella spp. rods Culture method with biochemical and serological confirmation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obecność pałeczek Salmonella spp., Shigella spp. Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-SBM-04 edycja 4 z dnia 29.09.2022 r.","norm_bases":["PB-SBM-04 edycja 4 z dnia 29.09.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kał, wymaz z odbytu Obecność pałeczek Salmonella spp., Shigella spp. Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-SBM-04 edycja 4 z dnia 29.09.2022 r. Kal, wymaz z odbytu Obecnosc paleczek Salmonella spp., Shigella spp. Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-SBM-04 edycja 4 z dnia 29.09.2022 r.","categories":["microbiology"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Faeces, rectal swab Presence of Salmonella spp., Shigella spp. rods Culture method with biochemical and serological confirmation PB-SBM-04 edycja 4 z dnia 29.09.2022 r.","search_zh":"粪便、肛拭子 PB-SBM-04 edycja 4 z dnia 29.09.2022 r.","test_object_zh":"粪便、肛拭子"},{"_id":"6a5a55fa9af9f73f382529cb","lab_id":"69ad52a3de79e566650fb5e0","country":"PL","accr_number":"AB 1152","accr_body":"PCA","test_object":"Kał, wymaz z odbytu","test_object_en":"Faeces, rectal swab","methodology":"Obecność i identyfikacja pałeczek Yersinia enterocolitica, Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","methodology_en":"Presence and identification of Yersinia enterocolitica rods, Culture method with biochemical and serological confirmation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obecność i identyfikacja pałeczek Yersinia enterocolitica, Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-SBM-01 edycja 5 z dnia 29.09.2022 r.","norm_bases":["PB-SBM-01 edycja 5 z dnia 29.09.2022 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kał, wymaz z odbytu Obecność i identyfikacja pałeczek Yersinia enterocolitica, Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-SBM-01 edycja 5 z dnia 29.09.2022 r. Kal, wymaz z odbytu Obecnosc i identyfikacja paleczek Yersinia enterocolitica, Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-SBM-01 edycja 5 z dnia 29.09.2022 r.","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Faeces, rectal swab Presence and identification of Yersinia enterocolitica rods, Culture method with biochemical and serological confirmation PB-SBM-01 edycja 5 z dnia 29.09.2022 r.","search_zh":"粪便、肛拭子 PB-SBM-01 edycja 5 z dnia 29.09.2022 r.","test_object_zh":"粪便、肛拭子"}],"has_pdf":true}