🇵🇱 PRZEDSIĘBIORSTWO USŁUGOWO-PRODUKCYJNE PL

PCA AB 1134 • Toruń, Poland • 25 methods

Environment

PRZEDSIĘBIORSTWO USŁUGOWO-PRODUKCYJNE is a laboratory accredited by PCA under number AB 1134 (Toruń, Poland). Its accreditation scope covers 25 test methods in the following areas: Environment. Test objects include: Waste gases, General environment – ambient air.

At a glance

  • Accreditation number: PCA AB 1134
  • Methods in scope: 25
  • Types of test objects: 2
  • City: Toruń, Poland
Accreditation number
AB 1134
Accreditation body
PCA
Address
„EKO-TOR” S.C., Michał Kopczyński, Mirosława Stawska, ul. Grunwaldzka 11/1, 87-100 Toruń
City
Toruń, Poland

What this laboratory tests (2)

Accreditation scope — test methods (25)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method Velocity (0,4 − 40) m/s Anemometric method PN-Z-04030-7:1994
2 Waste gases Sampling for determination of dust concentration
3 Waste gases Dust concentration Range: (0,001 – 18,7) g/m3 Gravimetric method
4 Waste gases Dust emission (calculated)
5 Waste gases Sulphur dioxide concentration Range: SO (6,0 − 2580) mg/m3 2 Non-dispersive infrared spectrometry method (NDIR) PN-ISO 10396:2001
6 Waste gases SO 2 emission (calculated)
7 Waste gases Nitrogen monoxide concentration Range: NO (3,0 − 1229) mg/m3 Non-dispersive infrared spectrometry method (NDIR) PN-ISO 10396:2001
8 Waste gases NO emission (calculated)
9 Waste gases Nitrogen oxides concentration Range: NO (2,0 − 1883) mg/m3 X Chemiluminescence method PN-ISO 10396:2001
10 Waste gases Emission of NO (NO and NO calculated X 2 as NO ) 2 (calculated)
11 Waste gases Carbon monoxide concentration Range: CO (3,0 − 1141) mg/m3 Non-dispersive infrared spectrometry method (NDIR) PN-ISO 10396:2001
12 Waste gases Carbon monoxide emission (calculated)
13 Waste gases Oxygen concentration Range: O (0,2 – 21) % 2 Paramagnetic method PN-ISO 10396:2001
14 Waste gases Oxygen concentration Range: (0,2 − 21) % Electrochemical method PN-ISO 10396:2001
15 Waste gases Carbon dioxide concentration Range: CO (0,1 – 18,1) % 2 Non-dispersive infrared spectrometry method (NDIR) PN-ISO 10396:2001
16 Waste gases Concentration of organic substances in gaseous and vapour form expressed as total gaseous organic carbon Range: (1,0 − 500) mg/m3 Continuous flame ionisation detection method (FID) PN-EN 12619:2013-05
17 Waste gases Emission of organic substances in gaseous and vapour form expressed as total gaseous organic carbon (calculated)
18 Waste gases Sampling for determination of the concentrations of organic compounds Aspiration method using activated carbon/ silica gel/ absorbing solutions PN-Z-04008-4:1999
19 Waste gases Emission of organic compounds (calculated)
20 Waste gases Sampling for determination of the concentration of individual gaseous organic compounds PN-EN 13649:2005
21 Waste gases Emission of individual gaseous organic compounds (calculated)
22 Waste gases Sampling for determination of the concentrations of inorganic and organic compounds Aspiration method PB-06 wydanie 13 z dnia 17.10.2022 r.
23 Waste gases Emission of inorganic and organic compounds (calculated)
24 General environment – ambient air Dust concentration Range: (0,01 − 10) mg/m3 Filtration-gravimetric method PB-08 wydanie 10 z dnia 17.10.2022 r.
25 General environment – ambient air Sampling for measurement of the concentration of: - dust - organic substances - inorganic substances - metals and their compounds Aspiration method

Reference standards (7)

PB-06 wydanie 13 z dnia 17.10.2022 r.
PB-08 wydanie 10 z dnia 17.10.2022 r.
PN-EN 12619:2013-05
PN-EN 13649:2005
PN-ISO 10396:2001
PN-Z-04008-4:1999
PN-Z-04030-7:1994