🇵🇱 RADMOR S.A. PL
Electronics & EMC
RADMOR S.A. is a laboratory accredited by PCA under number AB 1132 (Gdynia, Poland). Its accreditation scope covers 49 test methods in the following areas: Electronics & EMC. Test objects include: Military equipment. Electrical, telecommunications and electronic p…, Military equipment. Electrical, telecommunications and electronic p…, Military equipment. Electrical, telecommunications and electronic p…, Military equipment. Electrical, telecommunications and electronic p….
At a glance
- Accreditation number: PCA AB 1132
- Methods in scope: 49
- Types of test objects: 10
- City: Gdynia, Poland
- Accreditation number
- AB 1132
- Accreditation body
- PCA
- Address
- LABORATORIUM BADAWCZE, ul. Hutnicza 3, 81-212 Gdynia
- City
- Gdynia, Poland
What this laboratory tests (10)
- Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. — 14 methods
- Military equipment. Electrical, telecommunications and electronic products and equipment. — 9 methods
- Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. — 6 methods
- Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm — 6 methods
- Electrical, telecommunications and electronic products and equipment. — 5 methods
- Electrical, telecommunications and electronic products and equipment — 3 methods
- Military equipment. Electrical, telecommunication and electronic products and equipment — 2 methods
- Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Object dimensions up to: 50 cm x 50 cm x 50 cm — 2 methods
- Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Dimensions: 67 cm x 67 cm x 20 cm — 1 method
- Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Object dimensions: - horizontal cross-section Ǿ50 cm. — 1 method
Accreditation scope — test methods (49)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Frequency deviation Range: up to 1 GHz | PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.1 | ||
| 2 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Carrier power (conducted signal) Range: up to 1 GHz | PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.2 | ||
| 3 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Frequency deviation Range: up to 1 GHz | PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.4 | ||
| 4 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Adjacent channel power Range: up to 1 GHz | PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.5 | ||
| 5 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Transmitter spurious emissions (Power level into a specified load) Range: up to 12,75 GHz | PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.6.2 | ||
| 6 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Conducted emissions, antenna terminals Range: from 10 kHz to 18 GHz | NO-06-A500:2012 (p. 3.3 Procedura PCE-03) MIL-STD 461F (procedura CE106) MIL-STD 461G (procedura CE106) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.13 (procedura NCE03) | ||
| 7 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Intermodulation attenuation Range: up to 0,5 GHz | PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.7 | ||
| 8 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Maximum usable sensitivity (applied signal) Range: up to 1 GHz | PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.1 | ||
| 9 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Co-channel selectivity Range: up to 1 GHz | PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.3 | ||
| 10 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Adjacent channel selectivity Range: up to 1 GHz | PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.4 | ||
| 11 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Spurious response rejection Range: up to 2 GHz | PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.5 | ||
| 12 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Intermodulation response rejection Range: up to 1 GHz | PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.6 | ||
| 13 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Blocking or desensitization Range: up to 1 GHz | PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.7 | ||
| 14 | Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. | Spurious radiations (Conducted emission) Range: up to 12,75 GHz | PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.8.2 | ||
| 15 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Conducted disturbance voltage at supply terminals and telecommunication ports Frequency range: From 150 kHz to 30 MHz Conducted emissions, power supply leads Range: from 10 kHz to 10 MHz | PN-EN 55022:2011 | PN-EN 55032:2015-09 PN-EN 55016-2-1:2014-09 NO-06-A500:2012 (p. 3.2 Procedura PCE-02) MIL-STD 461F (procedura CE102) MIL-STD 461G (procedura CE102) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.12 (procedura NCE02) | ||
| 16 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Level of radiated disturbances, electric field Frequency range: From 10 kHz to 18 GHz Radiated emissions Frequency range: From 30 MHz to 6 GHz Measurement in a 3 m SAC chamber | NO-06-A500 | PRE-02 | MIL-STD | NO-A-STANAG-4370/AECTP-500- | PN-EN 55022:2011 | PN-EN 55032:2015-09 PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A2 | ||
| 17 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Immunity to conducted disturbances, power supply cables Frequency range: from 30 Hz to 150 kHz | NO-06-A500:2012 p. 3.4 (procedura PCS-01) MIL-STD 461F (procedura CS101) MIL-STD 461G (procedura CS101) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.16 (procedura NCS01) | ||
| 18 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Immunity to conducted disturbances, of all power and signal cables. Frequency range From 4 kHz to 200 MHz Direct measurement method Immunity to conducted disturbances induced by radio-frequency fields. Frequency range From 150 kHz to 80 MHz | NO-06-A500 | PCS-06 | MIL-STD | NO-A-STANAG-4370/AECTP-500- | PN-EN 61000-4-6:2014-04 PN-EN 61000-4-6:2024-03 PN-EN 55016-2-4:2005 | ||
| 19 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Immunity to conducted disturbances, impulse excitation | NO-06-A500:2012 p. 3.10 (procedura PCS-07) MIL-STD 461F (procedura CS115) MIL-STD 461G (procedura CS115) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.23 (procedura NCS08) | ||
| 20 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Immunity to conducted disturbances, damped sinusoidal wave, power and signal cables Frequency range from 10 kHz to 100 MHz | NO-06-A500:2012 p. 3.11 (procedura PCS-08) MIL-STD 461F (procedura CS116) MIL-STD 461G (procedura CS116) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.24 (procedura NCS09) | ||
| 21 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Immunity to radiated disturbances, magnetic field Frequency range: from 30 Hz to 100 kHz | NO-06-A500:2012 p. 3.16 (procedura PRS-01) MIL-STD 461F (procedura RS101) MIL-STD 461G (procedura RS101) | ||
| 22 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Immunity to radiated disturbances, electric field Frequency range: from 2 MHz to 18 GHz Test of immunity to radiated radio-frequency electromagnetic field Measurement in a SAC 3 m chamber | NO-06-A500:2012 p. 3.17 (procedura PRS-02) MIL-STD 461F (procedura RS103) MIL-STD 461G (procedura RS103) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.33 (procedura NRS02) NO-A-STANAG-4370/AECTP-500- 2:2021 pkt 3.14 (procedura NRS02.2) PN-EN 61000-4-3:2021-06 PN-EN 55016-2-4:2005 | ||
| 23 | Military equipment. Electrical, telecommunications and electronic products and equipment. | Immunity to electrostatic discharge Ranges: - up to ±15 kV (contact discharges) - up to ±30 kV (air discharges) | PN-EN 61000-4-2:2011 MIL-STD 461G (procedura CS118) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.27 (procedura NCS12) NO-A-STANAG-4370/AECTP-500- 2:2021 pkt 3.10 (procedura NCS12.2) | ||
| 24 | Electrical, telecommunications and electronic products and equipment. | Immunity to electrical surges 1,2/50 s, 8/20 s for power supply ports | PN-EN 61000-4-5:2014-10 | ||
| 25 | Electrical, telecommunications and electronic products and equipment. | Immunity to electrical surges 1,2/50 s, 8/20 s for signal and control ports | PN-EN 61000-4-5:2014-10 | ||
| 26 | Electrical, telecommunications and electronic products and equipment. | Immunity to electrical fast transient/burst Power supply port Range: 5,5 kV | PN-EN 61000-4-4:2013-05 | ||
| 27 | Electrical, telecommunications and electronic products and equipment. | Immunity to electrical fast transient/burst Signal and control port Range: up to 2 kV | PN-EN 61000-4-4:2013-05 | ||
| 28 | Electrical, telecommunications and electronic products and equipment. | Immunity to voltage dips, short interruptions and voltage variations Ranges: Voltage dips: 0 %, 40 %, 70 %, 80 % Voltage interruptions: 0% | PN-EN 61000-4-11:2020-11 | ||
| 29 | Military equipment. Electrical, telecommunication and electronic products and equipment | Electrical insulation resistance Ranges: R= from 50 kΩ to 200 GΩ U = (10 – 1000) V meas. DC | NO-06-A108:2005, p. 3.2 NO-06-A108:2021, p. 3.2 | ||
| 30 | Military equipment. Electrical, telecommunication and electronic products and equipment | Electric strength of the insulation Ranges: U = (0 - 5) kV p AC U = (0 - 6) kV p DC | NO-06-A108:2005, p. 3.3 NO-06-A108:2021, p. 3.3 | ||
| 31 | Electrical, telecommunications and electronic products and equipment | Immunity to power-frequency magnetic field | PN-EN 61000-4-8:2010 | ||
| 32 | Electrical, telecommunications and electronic products and equipment | Permissible levels of current harmonic emissions | PN-EN IEC 61000-3-2:2019-04 PN-EN IEC 61000-3-12:2012 PN-EN 61000-3-12:2012/A1:2024-11 | ||
| 33 | Electrical, telecommunications and electronic products and equipment | Voltage fluctuations and flicker in public low-voltage supply systems, caused by equipment with rated phase current 32 A | PN-EN 61000-3-3:2013-10 PN-EN 61000-3-11:2020 | ||
| 34 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm | Strength, resistance and overall resistance to low temperature Range: Minimum temperature -60 °C. | PN-EN 60068-2-1: 2009 NO-06-A107:2005, p. 4.3, 5.6 NO-06-A107:2021, p. 4.3, 5.6 MIL-STD 810F, Metoda 502.4, procedury I i II | ||
| 35 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm | Strength, resistance and overall resistance to elevated temperature Range: maximum temperature +170 °C, minimum relative humidity 20 %. | PN-EN 60068-2-2:2009 NO-06-A107:2005, p. 4.2, 5.7 NO-06-A107:2021, p. 4.2, 5.7 MIL-STD 810F, Metoda 501.4, procedury I i II | ||
| 36 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm | Strength, resistance and overall resistance to damp heat, steady state/cyclic Range: relative humidity up to 95 % temp. from +20 °C to +85 °C | PN-EN 60068-2-30:2008 PN-EN 60068-2-78:2013-11 NO-06-A107:2005, p. 4.4, Metoda 1, 2 i Metoda 3, p.5.10 NO-06-A107:2021, p. 4.4, Metoda 1, 2 i Metoda 3, p.5.10 MIL-STD 810F, Metoda 507.4 | ||
| 37 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm | Strength and resistance to temperature changes Range: min. temp. -60 °C, max. temp. +170 °C. Method: one chamber. | PN-EN IEC 60068-2-14:2024-04, próba Nb PN-EN 60068-2-14:2009, próba Nb NO-06-A107:2005, p. 4.5, Metoda 2, p. 5.9 NO-06-A107:2021, p. 4.5, Metoda 2, p. 5.9 | ||
| 38 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm | Strength and resistance to temperature changes Range: min. temp. -60 °C, max. temp. +170 °C. Method: two chambers | PN-EN IEC 60068-2-14:2024-04, próba Na PN-EN 60068-2-14:2009, próba Na NO-06-A107:2005, p. 4.5, Metoda 1, p.5.8 NO-06-A107:2021, p. 4.5, Metoda 1, p.5.8 MIL-STD 810F, Metoda 503.4, procedury I i II | ||
| 39 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm | Resistance to condensation atmospheric deposits (frost and dew) | NO-06–A107:2005, p 4.10. NO-06–A107:2021, p 4.10. | ||
| 40 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. | Mechanical resonances of the structure. Range: frequency: (5 – 40) Hz. | NO-06-A107:2005, p. 2.2 NO-06-A107:2021, p. 2.2 | ||
| 41 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. | Strength, resistance and overall resistance to sinusoidal mechanical vibration Ranges: Frequency: (1 – 3000) Hz | PN-EN 60068-2-6:2008 NO-06-A107:2005, p. 2.3, 2.7, 2.12, 3.2 NO-06-A107:2021, p. 2.3, 2.7, 2.12, 3.2 MIL-STD 810F, Metoda 514.5, procedura I | ||
| 42 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. | Strength, resistance and overall resistance to mechanical shocks (half-sine / trapezoid). Ranges: Peak acceleration amplitude up to 1500 m/s² respectively Shock duration: (1 - 50) ms. Repetition frequency up to 3 Hz. | PN-EN 60068-2-27:2009 NO-06-A107:2005, p. 2.5, 2.9, 2.13, 3.4 NO-06-A107:2021, p. 2.5, 2.9, 2.13, 3.4 | ||
| 43 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. | Strength, resistance and overall resistance to broadband random vibration Frequency (10 – 2000) Hz Root mean square value G up to RMS 30 g . n | PN-EN 60068-2-64:2008 NO-06-A107:2005 | NO-06-A107 | MIL-STD- | ||
| 44 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. | Overall strength and resistance to transport | NO-06-A107:2005, p 2.10 NO-06-A107:2021, p 2.10 | ||
| 45 | Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. | Resistance to free falls, drops and topples | PN-EN 60068-2-31:2010 NO-06-A107:2005, p. 2.11 NO-06-A107:2021, p. 2.11 MIL-STD 810F, Metoda 516.5, procedura IV | ||
| 46 | Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Object dimensions: - horizontal cross-section Ǿ50 cm. | Tightness. Resistance to immersion in water Code IPX7 – IPX8 | PN-EN 60529:2003, p. 14.2.7 i 14.2.8 NO-06-A107:2005, p. 4.16, Metoda 2 NO-06-A107:2021, p. 4.16, Metoda 2 MIL-STD 810F, Metoda 512.4, procedura I | ||
| 47 | Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Object dimensions up to: 50 cm x 50 cm x 50 cm | Protection against splashing water Code IPX3 - IPX4 | PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 | ||
| 48 | Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Object dimensions up to: 50 cm x 50 cm x 50 cm | Strength and resistance to rain (drip-proofness) Code IPX1 – IPX2 | PN-EN 60529:2003, p. 14.2.1 i p. 14.2.2 PN-EN 60529:2003/A2:2014-07 NO-06-A107:2005, p.4.18 NO-06-A107:2021, p.4.18 MIL-STD 810F, Metoda 506.4, procedura III | ||
| 49 | Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Dimensions: 67 cm x 67 cm x 20 cm | Strength and resistance to dust (dust-tightness) Code IP5X | PN-EN 60529:2003, p. 13.4 i 13.5, kategoria 2 NO-06-A107:2005, p. 4.12, Metoda 2, p.5.15 NO-06-A107:2021, p. 4.12, Metoda 2, p.5.15 | ||
Reference standards (56)
MIL-STD
MIL-STD-
NO-06-A107
NO-06-A107:2005, p 2.10 NO-06-A107:2021, p 2.10
NO-06-A107:2005, p. 2.2 NO-06-A107:2021, p. 2.2
NO-06-A108:2005, p. 3.2 NO-06-A108:2021, p. 3.2
NO-06-A108:2005, p. 3.3 NO-06-A108:2021, p. 3.3
NO-06-A500
NO-06-A500:2012 (p. 3.3 Procedura PCE-03) MIL-STD 461F (procedura CE106) MIL-STD 461G (procedura CE106) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.13 (procedura NCE03)
NO-06-A500:2012 p. 3.10 (procedura PCS-07) MIL-STD 461F (procedura CS115) MIL-STD 461G (procedura CS115) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.23 (procedura NCS08)
NO-06-A500:2012 p. 3.11 (procedura PCS-08) MIL-STD 461F (procedura CS116) MIL-STD 461G (procedura CS116) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.24 (procedura NCS09)
NO-06-A500:2012 p. 3.16 (procedura PRS-01) MIL-STD 461F (procedura RS101) MIL-STD 461G (procedura RS101)
NO-06-A500:2012 p. 3.17 (procedura PRS-02) MIL-STD 461F (procedura RS103) MIL-STD 461G (procedura RS103) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.33 (procedura NRS02) NO-A-STANAG-4370/AECTP-500- 2:2021 pkt 3.14 (procedura NRS02.2) PN-EN 61000-4-3:2021-06 PN-EN 55016-2-4:2005
NO-06-A500:2012 p. 3.4 (procedura PCS-01) MIL-STD 461F (procedura CS101) MIL-STD 461G (procedura CS101) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.16 (procedura NCS01)
NO-06–A107:2005, p 4.10. NO-06–A107:2021, p 4.10.
NO-A-STANAG-4370/AECTP-500-
PCS-06
PN-EN 55022:2011
PN-EN 55032:2015-09 PN-EN 55016-2-1:2014-09 NO-06-A500:2012 (p. 3.2 Procedura PCE-02) MIL-STD 461F (procedura CE102) MIL-STD 461G (procedura CE102) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.12 (procedura NCE02)
PN-EN 55032:2015-09 PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A2
PN-EN 60068-2-1: 2009 NO-06-A107:2005, p. 4.3, 5.6 NO-06-A107:2021, p. 4.3, 5.6 MIL-STD 810F, Metoda 502.4, procedury I i II
PN-EN 60068-2-27:2009 NO-06-A107:2005, p. 2.5, 2.9, 2.13, 3.4 NO-06-A107:2021, p. 2.5, 2.9, 2.13, 3.4
PN-EN 60068-2-2:2009 NO-06-A107:2005, p. 4.2, 5.7 NO-06-A107:2021, p. 4.2, 5.7 MIL-STD 810F, Metoda 501.4, procedury I i II
PN-EN 60068-2-30:2008 PN-EN 60068-2-78:2013-11 NO-06-A107:2005, p. 4.4, Metoda 1, 2 i Metoda 3, p.5.10 NO-06-A107:2021, p. 4.4, Metoda 1, 2 i Metoda 3, p.5.10 MIL-STD 810F, Metoda 507.4
PN-EN 60068-2-31:2010 NO-06-A107:2005, p. 2.11 NO-06-A107:2021, p. 2.11 MIL-STD 810F, Metoda 516.5, procedura IV
PN-EN 60068-2-64:2008 NO-06-A107:2005
PN-EN 60068-2-6:2008 NO-06-A107:2005, p. 2.3, 2.7, 2.12, 3.2 NO-06-A107:2021, p. 2.3, 2.7, 2.12, 3.2 MIL-STD 810F, Metoda 514.5, procedura I
PN-EN 60529:2003
PN-EN 60529:2003, p. 13.4 i 13.5, kategoria 2 NO-06-A107:2005, p. 4.12, Metoda 2, p.5.15 NO-06-A107:2021, p. 4.12, Metoda 2, p.5.15
PN-EN 60529:2003, p. 14.2.1 i p. 14.2.2 PN-EN 60529:2003/A2:2014-07 NO-06-A107:2005, p.4.18 NO-06-A107:2021, p.4.18 MIL-STD 810F, Metoda 506.4, procedura III
PN-EN 60529:2003, p. 14.2.7 i 14.2.8 NO-06-A107:2005, p. 4.16, Metoda 2 NO-06-A107:2021, p. 4.16, Metoda 2 MIL-STD 810F, Metoda 512.4, procedura I
PN-EN 60529:2003/A2:2014-07
PN-EN 61000-3-3:2013-10 PN-EN 61000-3-11:2020
PN-EN 61000-4-11:2020-11
PN-EN 61000-4-2:2011 MIL-STD 461G (procedura CS118) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.27 (procedura NCS12) NO-A-STANAG-4370/AECTP-500- 2:2021 pkt 3.10 (procedura NCS12.2)
PN-EN 61000-4-4:2013-05
PN-EN 61000-4-5:2014-10
PN-EN 61000-4-6:2014-04 PN-EN 61000-4-6:2024-03 PN-EN 55016-2-4:2005
PN-EN 61000-4-8:2010
PN-EN IEC 60068-2-14:2024-04, próba Na PN-EN 60068-2-14:2009, próba Na NO-06-A107:2005, p. 4.5, Metoda 1, p.5.8 NO-06-A107:2021, p. 4.5, Metoda 1, p.5.8 MIL-STD 810F, Metoda 503.4, procedury I i II
PN-EN IEC 60068-2-14:2024-04, próba Nb PN-EN 60068-2-14:2009, próba Nb NO-06-A107:2005, p. 4.5, Metoda 2, p. 5.9 NO-06-A107:2021, p. 4.5, Metoda 2, p. 5.9
PN-EN IEC 61000-3-2:2019-04 PN-EN IEC 61000-3-12:2012 PN-EN 61000-3-12:2012/A1:2024-11
PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.1
PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.2
PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.4
PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.5
PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.6.2
PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.7
PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.1
PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.3
PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.4
PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.5
PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.6
PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.7
PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.8.2
PRE-02