{"lab":{"_id":"69ad52a3de79e566650fb5c8","accr_number":"AB 1132","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAWCZE, ul. Hutnicza 3, 81-212 Gdynia","categories":["electronics"],"city":"Gdynia","imported_at":"2026-03-08T10:42:43.265Z","methods_count":49,"name":"RADMOR S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1132.pdf"],"scope_summary":"","search_text":"radmor s.a. laboratorium badawcze, ul. hutnicza 3, 81-212 gdynia other pharma electronics materials metrology construction environment water","status":"active","updated_at":"2026-03-08T14:50:18.588Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:18.588Z","email_confidence":"high","email_mx":true,"email_source":"https://www.radmor.com.pl/services/lab","parse_date":"2026-07-17T16:18:53.089Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"E/6; E/53; E/54; E/15","pl":"Badania elektryczne i elektroniczne wyrobów i wyposażenia elektrycznego, telekomunikacyjnego i elektronicznego, wyposażenia wojskowego","en":"Electric and electronic tests of electrical, telecommunication and electronic products and equipment, military equipment"},{"codes":"F/6; F/53; F/54; F/15","pl":"Badania kompatybilności elektromagnetycznej wyrobów i wyposażenia elektrycznego, telekomunikacyjnego i elektronicznego, wyposażenia wojskowego","en":"Electromagnetic compatibility (EMC) tests of electrical, telecommunication and electronic products and equipment, military equipment"},{"codes":"J/6; J/53; J/54; J/15","pl":"Badania mechaniczne wyrobów i wyposażenia elektrycznego, telekomunikacyjnego i elektronicznego, wyposażenia wojskowego","en":"Mechanical tests of electrical, telecommunication and electronic products and equipment, military equipment"},{"codes":"N/6; N/53; N/54; N/15","pl":"Badania właściwości fizycznych wyrobów i wyposażenia elektrycznego, telekomunikacyjnego i elektronicznego, wyposażenia wojskowego","en":"Tests of physical properties of electrical, telecommunication and electronic products and equipment, military equipment"}],"issue":{"no":"18","date":"12.12.2025"},"map_coord":[54.538597,18.491974],"map_geo":"nominatim-street","has_en":true,"category_counts":{"electronics":49,"environment":2,"construction":2,"water":1},"category_scores":{"electronics":44.46,"environment":0.07,"construction":0.07,"water":0.02},"has_zh":true},"methods":[{"_id":"6a5a55ed9af9f73f3825027c","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment.","methodology":"Odchyłka częstotliwości Zakres: do 1 GHz","methodology_en":"Frequency deviation Range: up to 1 GHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odchyłka częstotliwości Zakres: do 1 GHz","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.1","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone. Odchyłka częstotliwości Zakres: do 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.1 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Urzadzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone glownie do transmisji analogowego sygnalu mowy, wyposazone w zlacze RF 50 Ω, w tym stacje bazowe, urzadzenia przewozne i noszone. Odchylka czestotliwosci Zakres: do 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.1","categories":["electronics"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Frequency deviation Range: up to 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.1","search_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。 PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.1","test_object_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。"},{"_id":"6a5a55ed9af9f73f3825027d","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment.","methodology":"Moc fali nośnej (sygnał doprowadzony) Zakres: do 1 GHz","methodology_en":"Carrier power (conducted signal) Range: up to 1 GHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moc fali nośnej (sygnał doprowadzony) Zakres: do 1 GHz","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.2","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone. Moc fali nośnej (sygnał doprowadzony) Zakres: do 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.2 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Urzadzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone glownie do transmisji analogowego sygnalu mowy, wyposazone w zlacze RF 50 Ω, w tym stacje bazowe, urzadzenia przewozne i noszone. Moc fali nosnej (sygnal doprowadzony) Zakres: do 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.2","categories":["electronics"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Carrier power (conducted signal) Range: up to 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.2","search_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。 PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.2","test_object_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。"},{"_id":"6a5a55ed9af9f73f3825027e","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment.","methodology":"Dewiacja częstotliwości Zakres: do 1 GHz","methodology_en":"Frequency deviation Range: up to 1 GHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Dewiacja częstotliwości Zakres: do 1 GHz","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.4","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone. Dewiacja częstotliwości Zakres: do 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.4 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Urzadzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone glownie do transmisji analogowego sygnalu mowy, wyposazone w zlacze RF 50 Ω, w tym stacje bazowe, urzadzenia przewozne i noszone. Dewiacja czestotliwosci Zakres: do 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.4","categories":["electronics"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Frequency deviation Range: up to 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.4","search_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。 PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.4","test_object_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。"},{"_id":"6a5a55ed9af9f73f3825027f","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment.","methodology":"Moc w sąsiednim kanale Zakres: do 1 GHz","methodology_en":"Adjacent channel power Range: up to 1 GHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moc w sąsiednim kanale Zakres: do 1 GHz","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.5","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone. Moc w sąsiednim kanale Zakres: do 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.5 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Urzadzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone glownie do transmisji analogowego sygnalu mowy, wyposazone w zlacze RF 50 Ω, w tym stacje bazowe, urzadzenia przewozne i noszone. Moc w sasiednim kanale Zakres: do 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.5","categories":["electronics"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Adjacent channel power Range: up to 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.5","search_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。 PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.5","test_object_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。"},{"_id":"6a5a55ed9af9f73f38250280","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment.","methodology":"Emisje uboczne nadajnika (Poziom mocy na ustalonym obciążeniu) Zakres: do 12,75 GHz","methodology_en":"Transmitter spurious emissions (Power level into a specified load) Range: up to 12,75 GHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisje uboczne nadajnika (Poziom mocy na ustalonym obciążeniu) Zakres: do 12,75 GHz","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.6.2","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.6.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone. Emisje uboczne nadajnika (Poziom mocy na ustalonym obciążeniu) Zakres: do 12,75 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.6.2 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Urzadzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone glownie do transmisji analogowego sygnalu mowy, wyposazone w zlacze RF 50 Ω, w tym stacje bazowe, urzadzenia przewozne i noszone. Emisje uboczne nadajnika (Poziom mocy na ustalonym obciazeniu) Zakres: do 12,75 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.6.2","categories":["electronics"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Transmitter spurious emissions (Power level into a specified load) Range: up to 12,75 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.6.2","search_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。 PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.6.2","test_object_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。"},{"_id":"6a5a55ed9af9f73f38250281","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment.","methodology":"Emisje przewodzone, terminale antenowe Zakres: od 10 kHz do 18 GHz","methodology_en":"Conducted emissions, antenna terminals Range: from 10 kHz to 18 GHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisje przewodzone, terminale antenowe Zakres: od 10 kHz do 18 GHz","reference":"NO-06-A500:2012 (p. 3.3 Procedura PCE-03) MIL-STD 461F (procedura CE106) MIL-STD 461G (procedura CE106) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.13 (procedura NCE03)","norm_bases":["NO-06-A500:2012 (p. 3.3 Procedura PCE-03) MIL-STD 461F (procedura CE106) MIL-STD 461G (procedura CE106) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.13 (procedura NCE03)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone. Emisje przewodzone, terminale antenowe Zakres: od 10 kHz do 18 GHz NO-06-A500:2012 (p. 3.3 Procedura PCE-03) MIL-STD 461F (procedura CE106) MIL-STD 461G (procedura CE106) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.13 (procedura NCE03) Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Urzadzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone glownie do transmisji analogowego sygnalu mowy, wyposazone w zlacze RF 50 Ω, w tym stacje bazowe, urzadzenia przewozne i noszone. Emisje przewodzone, terminale antenowe Zakres: od 10 kHz do 18 GHz NO-06-A500:2012 (p. 3.3 Procedura PCE-03) MIL-STD 461F (procedura CE106) MIL-STD 461G (procedura CE106) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.13 (procedura NCE03)","categories":["electronics"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Conducted emissions, antenna terminals Range: from 10 kHz to 18 GHz NO-06-A500:2012 (p. 3.3 Procedura PCE-03) MIL-STD 461F (procedura CE106) MIL-STD 461G (procedura CE106) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.13 (procedura NCE03)","search_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。 NO-06-A500:2012 (p. 3.3 Procedura PCE-03) MIL-STD 461F (procedura CE106) MIL-STD 461G (procedura CE106) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.13 (procedura NCE03)","test_object_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。"},{"_id":"6a5a55ed9af9f73f38250282","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment.","methodology":"Tłumienność intermodulacji Zakres: do 0,5 GHz","methodology_en":"Intermodulation attenuation Range: up to 0,5 GHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Tłumienność intermodulacji Zakres: do 0,5 GHz","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.7","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone. Tłumienność intermodulacji Zakres: do 0,5 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.7 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Urzadzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone glownie do transmisji analogowego sygnalu mowy, wyposazone w zlacze RF 50 Ω, w tym stacje bazowe, urzadzenia przewozne i noszone. Tlumiennosc intermodulacji Zakres: do 0,5 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.7","categories":["electronics"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Intermodulation attenuation Range: up to 0,5 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.7","search_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。 PN-ETSI EN 300 086 V2.1.2:2017-02 p. 7.7","test_object_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。"},{"_id":"6a5a55ed9af9f73f38250283","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment.","methodology":"Maksymalna czułość użytkowa (sygnał doprowadzony) Zakres: do 1 GHz","methodology_en":"Maximum usable sensitivity (applied signal) Range: up to 1 GHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Maksymalna czułość użytkowa (sygnał doprowadzony) Zakres: do 1 GHz","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.1","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone. Maksymalna czułość użytkowa (sygnał doprowadzony) Zakres: do 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.1 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Urzadzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone glownie do transmisji analogowego sygnalu mowy, wyposazone w zlacze RF 50 Ω, w tym stacje bazowe, urzadzenia przewozne i noszone. Maksymalna czulosc uzytkowa (sygnal doprowadzony) Zakres: do 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.1","categories":["electronics"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Maximum usable sensitivity (applied signal) Range: up to 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.1","search_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。 PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.1","test_object_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。"},{"_id":"6a5a55ed9af9f73f38250284","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment.","methodology":"Selektywność wspólnokanałowa Zakres: do 1 GHz","methodology_en":"Co-channel selectivity Range: up to 1 GHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Selektywność wspólnokanałowa Zakres: do 1 GHz","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.3","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone. Selektywność wspólnokanałowa Zakres: do 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.3 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Urzadzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone glownie do transmisji analogowego sygnalu mowy, wyposazone w zlacze RF 50 Ω, w tym stacje bazowe, urzadzenia przewozne i noszone. Selektywnosc wspolnokanalowa Zakres: do 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.3","categories":["electronics"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Co-channel selectivity Range: up to 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.3","search_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。 PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.3","test_object_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。"},{"_id":"6a5a55ed9af9f73f38250285","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment.","methodology":"Selektywność sąsiedniokanałowa Zakres: do 1 GHz","methodology_en":"Adjacent channel selectivity Range: up to 1 GHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Selektywność sąsiedniokanałowa Zakres: do 1 GHz","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.4","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone. Selektywność sąsiedniokanałowa Zakres: do 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.4 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Urzadzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone glownie do transmisji analogowego sygnalu mowy, wyposazone w zlacze RF 50 Ω, w tym stacje bazowe, urzadzenia przewozne i noszone. Selektywnosc sasiedniokanalowa Zakres: do 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.4","categories":["electronics"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Adjacent channel selectivity Range: up to 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.4","search_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。 PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.4","test_object_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。"},{"_id":"6a5a55ed9af9f73f38250286","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment.","methodology":"Selektywność w stosunku do sygnałów o częstotliwościach niepożądanych Zakres: do 2 GHz","methodology_en":"Spurious response rejection Range: up to 2 GHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Selektywność w stosunku do sygnałów o częstotliwościach niepożądanych Zakres: do 2 GHz","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.5","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone. Selektywność w stosunku do sygnałów o częstotliwościach niepożądanych Zakres: do 2 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.5 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Urzadzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone glownie do transmisji analogowego sygnalu mowy, wyposazone w zlacze RF 50 Ω, w tym stacje bazowe, urzadzenia przewozne i noszone. Selektywnosc w stosunku do sygnalow o czestotliwosciach niepozadanych Zakres: do 2 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.5","categories":["electronics"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Spurious response rejection Range: up to 2 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.5","search_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。 PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.5","test_object_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。"},{"_id":"6a5a55ed9af9f73f38250287","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment.","methodology":"Odporność na zakłócenia intermodulacyjne Zakres: do 1 GHz","methodology_en":"Intermodulation response rejection Range: up to 1 GHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zakłócenia intermodulacyjne Zakres: do 1 GHz","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.6","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone. Odporność na zakłócenia intermodulacyjne Zakres: do 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.6 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Urzadzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone glownie do transmisji analogowego sygnalu mowy, wyposazone w zlacze RF 50 Ω, w tym stacje bazowe, urzadzenia przewozne i noszone. Odpornosc na zaklocenia intermodulacyjne Zakres: do 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.6","categories":["electronics"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Intermodulation response rejection Range: up to 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.6","search_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。 PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.6","test_object_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。"},{"_id":"6a5a55ed9af9f73f38250288","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment.","methodology":"Blokowanie lub zmniejszenie czułości Zakres: do 1 GHz","methodology_en":"Blocking or desensitization Range: up to 1 GHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Blokowanie lub zmniejszenie czułości Zakres: do 1 GHz","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.7","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone. Blokowanie lub zmniejszenie czułości Zakres: do 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.7 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Urzadzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone glownie do transmisji analogowego sygnalu mowy, wyposazone w zlacze RF 50 Ω, w tym stacje bazowe, urzadzenia przewozne i noszone. Blokowanie lub zmniejszenie czulosci Zakres: do 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.7","categories":["electronics"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Blocking or desensitization Range: up to 1 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.7","search_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。 PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.7","test_object_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。"},{"_id":"6a5a55ed9af9f73f38250289","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment.","methodology":"Promieniowania uboczne (Emisja przewodzona) Zakres: do 12,75 GHz","methodology_en":"Spurious radiations (Conducted emission) Range: up to 12,75 GHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Promieniowania uboczne (Emisja przewodzona) Zakres: do 12,75 GHz","reference":"PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.8.2","norm_bases":["PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.8.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Urządzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone głównie do transmisji analogowego sygnału mowy, wyposażone w złącze RF 50 Ω, w tym stacje bazowe, urządzenia przewoźne i noszone. Promieniowania uboczne (Emisja przewodzona) Zakres: do 12,75 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.8.2 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Urzadzenia do stosowania w sieciach dyspozytorskich, w zakresie RF przeznaczone glownie do transmisji analogowego sygnalu mowy, wyposazone w zlacze RF 50 Ω, w tym stacje bazowe, urzadzenia przewozne i noszone. Promieniowania uboczne (Emisja przewodzona) Zakres: do 12,75 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.8.2","categories":["environment","electronics"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Equipment for use in dispatch radio networks, in the RF range intended mainly for the transmission of analogue speech signals, fitted with a 50 Ω RF connector, including base stations, mobile and portable equipment. Spurious radiations (Conducted emission) Range: up to 12,75 GHz PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.8.2","search_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。 PN-ETSI EN 300 086 V2.1.2:2017-02 p. 8.8.2","test_object_zh":"军用装备。电气、电信与电子产品及装备。用于调度网络、主要用于传输模拟话音信号并配有 50 Ω 射频接口的射频设备，其中包括基站、车载设备与便携设备。"},{"_id":"6a5a55ed9af9f73f3825028a","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment.","methodology":"Napięcie zaburzeń przewodzonych na zaciskach zasilania oraz przyłączach telekomunikacyjnych Zakres częstotliwości: Od 150 kHz do 30 MHz Emisje przewodzone, przewody zasilające Zakres: od 10 kHz do 10 MHz","methodology_en":"Conducted disturbance voltage at supply terminals and telecommunication ports Frequency range: From 150 kHz to 30 MHz Conducted emissions, power supply leads Range: from 10 kHz to 10 MHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Napięcie zaburzeń przewodzonych na zaciskach zasilania oraz przyłączach telekomunikacyjnych Zakres częstotliwości: Od 150 kHz do 30 MHz Emisje przewodzone, przewody zasilające Zakres: od 10 kHz do 10 MHz","reference":"PN-EN 55022:2011 | PN-EN 55032:2015-09 PN-EN 55016-2-1:2014-09 NO-06-A500:2012 (p. 3.2 Procedura PCE-02) MIL-STD 461F (procedura CE102) MIL-STD 461G (procedura CE102) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.12 (procedura NCE02)","norm_bases":["PN-EN 55022:2011","PN-EN 55032:2015-09 PN-EN 55016-2-1:2014-09 NO-06-A500:2012 (p. 3.2 Procedura PCE-02) MIL-STD 461F (procedura CE102) MIL-STD 461G (procedura CE102) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.12 (procedura NCE02)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Napięcie zaburzeń przewodzonych na zaciskach zasilania oraz przyłączach telekomunikacyjnych Zakres częstotliwości: Od 150 kHz do 30 MHz Emisje przewodzone, przewody zasilające Zakres: od 10 kHz do 10 MHz PN-EN 55022:2011 | PN-EN 55032:2015-09 PN-EN 55016-2-1:2014-09 NO-06-A500:2012 (p. 3.2 Procedura PCE-02) MIL-STD 461F (procedura CE102) MIL-STD 461G (procedura CE102) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.12 (procedura NCE02) Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne. Napiecie zaburzen przewodzonych na zaciskach zasilania oraz przylaczach telekomunikacyjnych Zakres czestotliwosci: Od 150 kHz do 30 MHz Emisje przewodzone, przewody zasilajace Zakres: od 10 kHz do 10 MHz PN-EN 55022:2011 | PN-EN 55032:2015-09 PN-EN 55016-2-1:2014-09 NO-06-A500:2012 (p. 3.2 Procedura PCE-02) MIL-STD 461F (procedura CE102) MIL-STD 461G (procedura CE102) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.12 (procedura NCE02)","categories":["electronics"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment. Conducted disturbance voltage at supply terminals and telecommunication ports Frequency range: From 150 kHz to 30 MHz Conducted emissions, power supply leads Range: from 10 kHz to 10 MHz PN-EN 55022:2011 | PN-EN 55032:2015-09 PN-EN 55016-2-1:2014-09 NO-06-A500:2012 (p. 3.2 Procedura PCE-02) MIL-STD 461F (procedura CE102) MIL-STD 461G (procedura CE102) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.12 (procedura NCE02)","search_zh":"军用装备。电气、电信与电子产品及装备。 PN-EN 55022:2011 | PN-EN 55032:2015-09 PN-EN 55016-2-1:2014-09 NO-06-A500:2012 (p. 3.2 Procedura PCE-02) MIL-STD 461F (procedura CE102) MIL-STD 461G (procedura CE102) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.12 (procedura NCE02)","test_object_zh":"军用装备。电气、电信与电子产品及装备。"},{"_id":"6a5a55ed9af9f73f3825028b","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment.","methodology":"Poziom zaburzeń promieniowanych, pole elektryczne Zakres częstotliwości: Od 10 kHz do 18 GHz Emisje promieniowane Zakres częstotliwości: Od 30 MHz do 6 GHz Pomiar w komorze SAC 3 m","methodology_en":"Level of radiated disturbances, electric field Frequency range: From 10 kHz to 18 GHz Radiated emissions Frequency range: From 30 MHz to 6 GHz Measurement in a 3 m SAC chamber","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom zaburzeń promieniowanych, pole elektryczne Zakres częstotliwości: Od 10 kHz do 18 GHz Emisje promieniowane Zakres częstotliwości: Od 30 MHz do 6 GHz Pomiar w komorze SAC 3 m","reference":"NO-06-A500 | PRE-02 | MIL-STD | NO-A-STANAG-4370/AECTP-500- | PN-EN 55022:2011 | PN-EN 55032:2015-09 PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A2","norm_bases":["NO-06-A500","PRE-02","MIL-STD","NO-A-STANAG-4370/AECTP-500-","PN-EN 55022:2011","PN-EN 55032:2015-09 PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Poziom zaburzeń promieniowanych, pole elektryczne Zakres częstotliwości: Od 10 kHz do 18 GHz Emisje promieniowane Zakres częstotliwości: Od 30 MHz do 6 GHz Pomiar w komorze SAC 3 m NO-06-A500 | PRE-02 | MIL-STD | NO-A-STANAG-4370/AECTP-500- | PN-EN 55022:2011 | PN-EN 55032:2015-09 PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A2 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne. Poziom zaburzen promieniowanych, pole elektryczne Zakres czestotliwosci: Od 10 kHz do 18 GHz Emisje promieniowane Zakres czestotliwosci: Od 30 MHz do 6 GHz Pomiar w komorze SAC 3 m NO-06-A500 | PRE-02 | MIL-STD | NO-A-STANAG-4370/AECTP-500- | PN-EN 55022:2011 | PN-EN 55032:2015-09 PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A2","categories":["electronics"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment. Level of radiated disturbances, electric field Frequency range: From 10 kHz to 18 GHz Radiated emissions Frequency range: From 30 MHz to 6 GHz Measurement in a 3 m SAC chamber NO-06-A500 | PRE-02 | MIL-STD | NO-A-STANAG-4370/AECTP-500- | PN-EN 55022:2011 | PN-EN 55032:2015-09 PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A2","search_zh":"军用装备。电气、电信与电子产品及装备。 NO-06-A500 | PRE-02 | MIL-STD | NO-A-STANAG-4370/AECTP-500- | PN-EN 55022:2011 | PN-EN 55032:2015-09 PN-EN 55016-2-3:2017-06 PN-EN 55016-2-3:2017-06/A2","test_object_zh":"军用装备。电气、电信与电子产品及装备。"},{"_id":"6a5a55ed9af9f73f3825028c","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment.","methodology":"Odporność na narażenia przewodzone, przewody zasilające Zakres częstotliwości: od 30 Hz do 150 kHz","methodology_en":"Immunity to conducted disturbances, power supply cables Frequency range: from 30 Hz to 150 kHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na narażenia przewodzone, przewody zasilające Zakres częstotliwości: od 30 Hz do 150 kHz","reference":"NO-06-A500:2012 p. 3.4 (procedura PCS-01) MIL-STD 461F (procedura CS101) MIL-STD 461G (procedura CS101) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.16 (procedura NCS01)","norm_bases":["NO-06-A500:2012 p. 3.4 (procedura PCS-01) MIL-STD 461F (procedura CS101) MIL-STD 461G (procedura CS101) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.16 (procedura NCS01)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Odporność na narażenia przewodzone, przewody zasilające Zakres częstotliwości: od 30 Hz do 150 kHz NO-06-A500:2012 p. 3.4 (procedura PCS-01) MIL-STD 461F (procedura CS101) MIL-STD 461G (procedura CS101) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.16 (procedura NCS01) Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne. Odpornosc na narazenia przewodzone, przewody zasilajace Zakres czestotliwosci: od 30 Hz do 150 kHz NO-06-A500:2012 p. 3.4 (procedura PCS-01) MIL-STD 461F (procedura CS101) MIL-STD 461G (procedura CS101) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.16 (procedura NCS01)","categories":["electronics"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment. Immunity to conducted disturbances, power supply cables Frequency range: from 30 Hz to 150 kHz NO-06-A500:2012 p. 3.4 (procedura PCS-01) MIL-STD 461F (procedura CS101) MIL-STD 461G (procedura CS101) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.16 (procedura NCS01)","search_zh":"军用装备。电气、电信与电子产品及装备。 NO-06-A500:2012 p. 3.4 (procedura PCS-01) MIL-STD 461F (procedura CS101) MIL-STD 461G (procedura CS101) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.16 (procedura NCS01)","test_object_zh":"军用装备。电气、电信与电子产品及装备。"},{"_id":"6a5a55ed9af9f73f3825028d","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment.","methodology":"Odporność na narażenia przewodzone, wszystkich kabli zasilania i sygnałowych. Zakres częstotliwości Od 4 kHz do 200 MHz Metoda pomiarowa bezpośrednia Odporność na zaburzenia przewodzone indukowane przez pola o częstotliwości radiowej. Zakres częstotliwości Od 150 kHz do 80 MHz","methodology_en":"Immunity to conducted disturbances, of all power and signal cables. Frequency range From 4 kHz to 200 MHz Direct measurement method Immunity to conducted disturbances induced by radio-frequency fields. Frequency range From 150 kHz to 80 MHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na narażenia przewodzone, wszystkich kabli zasilania i sygnałowych. Zakres częstotliwości Od 4 kHz do 200 MHz Metoda pomiarowa bezpośrednia Odporność na zaburzenia przewodzone indukowane przez pola o częstotliwości radiowej. Zakres częstotliwości Od 150 kHz do 80 MHz","reference":"NO-06-A500 | PCS-06 | MIL-STD | NO-A-STANAG-4370/AECTP-500- | PN-EN 61000-4-6:2014-04 PN-EN 61000-4-6:2024-03 PN-EN 55016-2-4:2005","norm_bases":["NO-06-A500","PCS-06","MIL-STD","NO-A-STANAG-4370/AECTP-500-","PN-EN 61000-4-6:2014-04 PN-EN 61000-4-6:2024-03 PN-EN 55016-2-4:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Odporność na narażenia przewodzone, wszystkich kabli zasilania i sygnałowych. Zakres częstotliwości Od 4 kHz do 200 MHz Metoda pomiarowa bezpośrednia Odporność na zaburzenia przewodzone indukowane przez pola o częstotliwości radiowej. Zakres częstotliwości Od 150 kHz do 80 MHz NO-06-A500 | PCS-06 | MIL-STD | NO-A-STANAG-4370/AECTP-500- | PN-EN 61000-4-6:2014-04 PN-EN 61000-4-6:2024-03 PN-EN 55016-2-4:2005 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne. Odpornosc na narazenia przewodzone, wszystkich kabli zasilania i sygnalowych. Zakres czestotliwosci Od 4 kHz do 200 MHz Metoda pomiarowa bezposrednia Odpornosc na zaburzenia przewodzone indukowane przez pola o czestotliwosci radiowej. Zakres czestotliwosci Od 150 kHz do 80 MHz NO-06-A500 | PCS-06 | MIL-STD | NO-A-STANAG-4370/AECTP-500- | PN-EN 61000-4-6:2014-04 PN-EN 61000-4-6:2024-03 PN-EN 55016-2-4:2005","categories":["electronics"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment. Immunity to conducted disturbances, of all power and signal cables. Frequency range From 4 kHz to 200 MHz Direct measurement method Immunity to conducted disturbances induced by radio-frequency fields. Frequency range From 150 kHz to 80 MHz NO-06-A500 | PCS-06 | MIL-STD | NO-A-STANAG-4370/AECTP-500- | PN-EN 61000-4-6:2014-04 PN-EN 61000-4-6:2024-03 PN-EN 55016-2-4:2005","search_zh":"军用装备。电气、电信与电子产品及装备。 NO-06-A500 | PCS-06 | MIL-STD | NO-A-STANAG-4370/AECTP-500- | PN-EN 61000-4-6:2014-04 PN-EN 61000-4-6:2024-03 PN-EN 55016-2-4:2005","test_object_zh":"军用装备。电气、电信与电子产品及装备。"},{"_id":"6a5a55ed9af9f73f3825028e","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment.","methodology":"Odporność na narażenia przewodzone, pobudzenie impulsowe","methodology_en":"Immunity to conducted disturbances, impulse excitation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na narażenia przewodzone, pobudzenie impulsowe","reference":"NO-06-A500:2012 p. 3.10 (procedura PCS-07) MIL-STD 461F (procedura CS115) MIL-STD 461G (procedura CS115) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.23 (procedura NCS08)","norm_bases":["NO-06-A500:2012 p. 3.10 (procedura PCS-07) MIL-STD 461F (procedura CS115) MIL-STD 461G (procedura CS115) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.23 (procedura NCS08)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Odporność na narażenia przewodzone, pobudzenie impulsowe NO-06-A500:2012 p. 3.10 (procedura PCS-07) MIL-STD 461F (procedura CS115) MIL-STD 461G (procedura CS115) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.23 (procedura NCS08) Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne. Odpornosc na narazenia przewodzone, pobudzenie impulsowe NO-06-A500:2012 p. 3.10 (procedura PCS-07) MIL-STD 461F (procedura CS115) MIL-STD 461G (procedura CS115) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.23 (procedura NCS08)","categories":["electronics"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment. Immunity to conducted disturbances, impulse excitation NO-06-A500:2012 p. 3.10 (procedura PCS-07) MIL-STD 461F (procedura CS115) MIL-STD 461G (procedura CS115) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.23 (procedura NCS08)","search_zh":"军用装备。电气、电信与电子产品及装备。 NO-06-A500:2012 p. 3.10 (procedura PCS-07) MIL-STD 461F (procedura CS115) MIL-STD 461G (procedura CS115) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.23 (procedura NCS08)","test_object_zh":"军用装备。电气、电信与电子产品及装备。"},{"_id":"6a5a55ed9af9f73f3825028f","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment.","methodology":"Odporność na narażenia przewodzone, tłumiona fala sinusoidalna, przewody zasilania i sygnałowe Zakres częstotliwości od 10 kHz do 100 MHz","methodology_en":"Immunity to conducted disturbances, damped sinusoidal wave, power and signal cables Frequency range from 10 kHz to 100 MHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na narażenia przewodzone, tłumiona fala sinusoidalna, przewody zasilania i sygnałowe Zakres częstotliwości od 10 kHz do 100 MHz","reference":"NO-06-A500:2012 p. 3.11 (procedura PCS-08) MIL-STD 461F (procedura CS116) MIL-STD 461G (procedura CS116) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.24 (procedura NCS09)","norm_bases":["NO-06-A500:2012 p. 3.11 (procedura PCS-08) MIL-STD 461F (procedura CS116) MIL-STD 461G (procedura CS116) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.24 (procedura NCS09)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Odporność na narażenia przewodzone, tłumiona fala sinusoidalna, przewody zasilania i sygnałowe Zakres częstotliwości od 10 kHz do 100 MHz NO-06-A500:2012 p. 3.11 (procedura PCS-08) MIL-STD 461F (procedura CS116) MIL-STD 461G (procedura CS116) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.24 (procedura NCS09) Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne. Odpornosc na narazenia przewodzone, tlumiona fala sinusoidalna, przewody zasilania i sygnalowe Zakres czestotliwosci od 10 kHz do 100 MHz NO-06-A500:2012 p. 3.11 (procedura PCS-08) MIL-STD 461F (procedura CS116) MIL-STD 461G (procedura CS116) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.24 (procedura NCS09)","categories":["electronics"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment. Immunity to conducted disturbances, damped sinusoidal wave, power and signal cables Frequency range from 10 kHz to 100 MHz NO-06-A500:2012 p. 3.11 (procedura PCS-08) MIL-STD 461F (procedura CS116) MIL-STD 461G (procedura CS116) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.24 (procedura NCS09)","search_zh":"军用装备。电气、电信与电子产品及装备。 NO-06-A500:2012 p. 3.11 (procedura PCS-08) MIL-STD 461F (procedura CS116) MIL-STD 461G (procedura CS116) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.24 (procedura NCS09)","test_object_zh":"军用装备。电气、电信与电子产品及装备。"},{"_id":"6a5a55ed9af9f73f38250290","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment.","methodology":"Odporność na narażenia promieniowane, pole magnetyczne Zakres częstotliwości: od 30 Hz do 100 kHz","methodology_en":"Immunity to radiated disturbances, magnetic field Frequency range: from 30 Hz to 100 kHz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na narażenia promieniowane, pole magnetyczne Zakres częstotliwości: od 30 Hz do 100 kHz","reference":"NO-06-A500:2012 p. 3.16 (procedura PRS-01) MIL-STD 461F (procedura RS101) MIL-STD 461G (procedura RS101)","norm_bases":["NO-06-A500:2012 p. 3.16 (procedura PRS-01) MIL-STD 461F (procedura RS101) MIL-STD 461G (procedura RS101)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Odporność na narażenia promieniowane, pole magnetyczne Zakres częstotliwości: od 30 Hz do 100 kHz NO-06-A500:2012 p. 3.16 (procedura PRS-01) MIL-STD 461F (procedura RS101) MIL-STD 461G (procedura RS101) Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne. Odpornosc na narazenia promieniowane, pole magnetyczne Zakres czestotliwosci: od 30 Hz do 100 kHz NO-06-A500:2012 p. 3.16 (procedura PRS-01) MIL-STD 461F (procedura RS101) MIL-STD 461G (procedura RS101)","categories":["electronics"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment. Immunity to radiated disturbances, magnetic field Frequency range: from 30 Hz to 100 kHz NO-06-A500:2012 p. 3.16 (procedura PRS-01) MIL-STD 461F (procedura RS101) MIL-STD 461G (procedura RS101)","search_zh":"军用装备。电气、电信与电子产品及装备。 NO-06-A500:2012 p. 3.16 (procedura PRS-01) MIL-STD 461F (procedura RS101) MIL-STD 461G (procedura RS101)","test_object_zh":"军用装备。电气、电信与电子产品及装备。"},{"_id":"6a5a55ed9af9f73f38250291","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment.","methodology":"Odporność na narażenia promieniowane, pole elektryczne Zakres częstotliwości: od 2 MHz do 18 GHz Badanie odporności na promieniowane pole elektromagnetyczne o częstotliwości radiowej Pomiar w komorze SAC 3 m","methodology_en":"Immunity to radiated disturbances, electric field Frequency range: from 2 MHz to 18 GHz Test of immunity to radiated radio-frequency electromagnetic field Measurement in a SAC 3 m chamber","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na narażenia promieniowane, pole elektryczne Zakres częstotliwości: od 2 MHz do 18 GHz Badanie odporności na promieniowane pole elektromagnetyczne o częstotliwości radiowej Pomiar w komorze SAC 3 m","reference":"NO-06-A500:2012 p. 3.17 (procedura PRS-02) MIL-STD 461F (procedura RS103) MIL-STD 461G (procedura RS103) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.33 (procedura NRS02) NO-A-STANAG-4370/AECTP-500- 2:2021 pkt 3.14 (procedura NRS02.2) PN-EN 61000-4-3:2021-06 PN-EN 55016-2-4:2005","norm_bases":["NO-06-A500:2012 p. 3.17 (procedura PRS-02) MIL-STD 461F (procedura RS103) MIL-STD 461G (procedura RS103) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.33 (procedura NRS02) NO-A-STANAG-4370/AECTP-500- 2:2021 pkt 3.14 (procedura NRS02.2) PN-EN 61000-4-3:2021-06 PN-EN 55016-2-4:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Odporność na narażenia promieniowane, pole elektryczne Zakres częstotliwości: od 2 MHz do 18 GHz Badanie odporności na promieniowane pole elektromagnetyczne o częstotliwości radiowej Pomiar w komorze SAC 3 m NO-06-A500:2012 p. 3.17 (procedura PRS-02) MIL-STD 461F (procedura RS103) MIL-STD 461G (procedura RS103) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.33 (procedura NRS02) NO-A-STANAG-4370/AECTP-500- 2:2021 pkt 3.14 (procedura NRS02.2) PN-EN 61000-4-3:2021-06 PN-EN 55016-2-4:2005 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne. Odpornosc na narazenia promieniowane, pole elektryczne Zakres czestotliwosci: od 2 MHz do 18 GHz Badanie odpornosci na promieniowane pole elektromagnetyczne o czestotliwosci radiowej Pomiar w komorze SAC 3 m NO-06-A500:2012 p. 3.17 (procedura PRS-02) MIL-STD 461F (procedura RS103) MIL-STD 461G (procedura RS103) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.33 (procedura NRS02) NO-A-STANAG-4370/AECTP-500- 2:2021 pkt 3.14 (procedura NRS02.2) PN-EN 61000-4-3:2021-06 PN-EN 55016-2-4:2005","categories":["electronics"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment. Immunity to radiated disturbances, electric field Frequency range: from 2 MHz to 18 GHz Test of immunity to radiated radio-frequency electromagnetic field Measurement in a SAC 3 m chamber NO-06-A500:2012 p. 3.17 (procedura PRS-02) MIL-STD 461F (procedura RS103) MIL-STD 461G (procedura RS103) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.33 (procedura NRS02) NO-A-STANAG-4370/AECTP-500- 2:2021 pkt 3.14 (procedura NRS02.2) PN-EN 61000-4-3:2021-06 PN-EN 55016-2-4:2005","search_zh":"军用装备。电气、电信与电子产品及装备。 NO-06-A500:2012 p. 3.17 (procedura PRS-02) MIL-STD 461F (procedura RS103) MIL-STD 461G (procedura RS103) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.33 (procedura NRS02) NO-A-STANAG-4370/AECTP-500- 2:2021 pkt 3.14 (procedura NRS02.2) PN-EN 61000-4-3:2021-06 PN-EN 55016-2-4:2005","test_object_zh":"军用装备。电气、电信与电子产品及装备。"},{"_id":"6a5a55ed9af9f73f38250292","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment.","methodology":"Odporność na wyładowania elektrostatyczne Zakresy: - do ±15 kV (wyładowania kontaktowe) - do ±30 kV (wyładowania w powietrzu)","methodology_en":"Immunity to electrostatic discharge Ranges: - up to ±15 kV (contact discharges) - up to ±30 kV (air discharges)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na wyładowania elektrostatyczne Zakresy: - do ±15 kV (wyładowania kontaktowe) - do ±30 kV (wyładowania w powietrzu)","reference":"PN-EN 61000-4-2:2011 MIL-STD 461G (procedura CS118) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.27 (procedura NCS12) NO-A-STANAG-4370/AECTP-500- 2:2021 pkt 3.10 (procedura NCS12.2)","norm_bases":["PN-EN 61000-4-2:2011 MIL-STD 461G (procedura CS118) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.27 (procedura NCS12) NO-A-STANAG-4370/AECTP-500- 2:2021 pkt 3.10 (procedura NCS12.2)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Odporność na wyładowania elektrostatyczne Zakresy: - do ±15 kV (wyładowania kontaktowe) - do ±30 kV (wyładowania w powietrzu) PN-EN 61000-4-2:2011 MIL-STD 461G (procedura CS118) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.27 (procedura NCS12) NO-A-STANAG-4370/AECTP-500- 2:2021 pkt 3.10 (procedura NCS12.2) Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne. Odpornosc na wyladowania elektrostatyczne Zakresy: - do ±15 kV (wyladowania kontaktowe) - do ±30 kV (wyladowania w powietrzu) PN-EN 61000-4-2:2011 MIL-STD 461G (procedura CS118) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.27 (procedura NCS12) NO-A-STANAG-4370/AECTP-500- 2:2021 pkt 3.10 (procedura NCS12.2)","categories":["electronics"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment. Immunity to electrostatic discharge Ranges: - up to ±15 kV (contact discharges) - up to ±30 kV (air discharges) PN-EN 61000-4-2:2011 MIL-STD 461G (procedura CS118) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.27 (procedura NCS12) NO-A-STANAG-4370/AECTP-500- 2:2021 pkt 3.10 (procedura NCS12.2)","search_zh":"军用装备。电气、电信与电子产品及装备。 PN-EN 61000-4-2:2011 MIL-STD 461G (procedura CS118) NO-A-STANAG-4370/AECTP-500- 1:2021 pkt 3.27 (procedura NCS12) NO-A-STANAG-4370/AECTP-500- 2:2021 pkt 3.10 (procedura NCS12.2)","test_object_zh":"军用装备。电气、电信与电子产品及装备。"},{"_id":"6a5a55ed9af9f73f38250293","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne.","test_object_en":"Electrical, telecommunications and electronic products and equipment.","methodology":"Odporność na udary elektryczne 1,2/50 s, 8/20 s dla przyłączy zasilania","methodology_en":"Immunity to electrical surges 1,2/50 s, 8/20 s for power supply ports","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na udary elektryczne 1,2/50 s, 8/20 s dla przyłączy zasilania","reference":"PN-EN 61000-4-5:2014-10","norm_bases":["PN-EN 61000-4-5:2014-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Odporność na udary elektryczne 1,2/50 s, 8/20 s dla przyłączy zasilania PN-EN 61000-4-5:2014-10 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne. Odpornosc na udary elektryczne 1,2/50 s, 8/20 s dla przylaczy zasilania PN-EN 61000-4-5:2014-10","categories":["electronics"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical, telecommunications and electronic products and equipment. Immunity to electrical surges 1,2/50 s, 8/20 s for power supply ports PN-EN 61000-4-5:2014-10","search_zh":"电气、电信与电子产品及装备。 PN-EN 61000-4-5:2014-10","test_object_zh":"电气、电信与电子产品及装备。"},{"_id":"6a5a55ed9af9f73f38250294","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne.","test_object_en":"Electrical, telecommunications and electronic products and equipment.","methodology":"Odporność na udary elektryczne 1,2/50 s, 8/20 s dla przyłączy sygnałowych i sterujących","methodology_en":"Immunity to electrical surges 1,2/50 s, 8/20 s for signal and control ports","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na udary elektryczne 1,2/50 s, 8/20 s dla przyłączy sygnałowych i sterujących","reference":"PN-EN 61000-4-5:2014-10","norm_bases":["PN-EN 61000-4-5:2014-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Odporność na udary elektryczne 1,2/50 s, 8/20 s dla przyłączy sygnałowych i sterujących PN-EN 61000-4-5:2014-10 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne. Odpornosc na udary elektryczne 1,2/50 s, 8/20 s dla przylaczy sygnalowych i sterujacych PN-EN 61000-4-5:2014-10","categories":["electronics"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical, telecommunications and electronic products and equipment. Immunity to electrical surges 1,2/50 s, 8/20 s for signal and control ports PN-EN 61000-4-5:2014-10","search_zh":"电气、电信与电子产品及装备。 PN-EN 61000-4-5:2014-10","test_object_zh":"电气、电信与电子产品及装备。"},{"_id":"6a5a55ed9af9f73f38250295","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne.","test_object_en":"Electrical, telecommunications and electronic products and equipment.","methodology":"Odporność na serie szybkich elektrycznych stanów przejściowych Przyłącze zasilania Zakres: 5,5 kV","methodology_en":"Immunity to electrical fast transient/burst Power supply port Range: 5,5 kV","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na serie szybkich elektrycznych stanów przejściowych Przyłącze zasilania Zakres: 5,5 kV","reference":"PN-EN 61000-4-4:2013-05","norm_bases":["PN-EN 61000-4-4:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Odporność na serie szybkich elektrycznych stanów przejściowych Przyłącze zasilania Zakres: 5,5 kV PN-EN 61000-4-4:2013-05 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne. Odpornosc na serie szybkich elektrycznych stanow przejsciowych Przylacze zasilania Zakres: 5,5 kV PN-EN 61000-4-4:2013-05","categories":["electronics"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical, telecommunications and electronic products and equipment. Immunity to electrical fast transient/burst Power supply port Range: 5,5 kV PN-EN 61000-4-4:2013-05","search_zh":"电气、电信与电子产品及装备。 PN-EN 61000-4-4:2013-05","test_object_zh":"电气、电信与电子产品及装备。"},{"_id":"6a5a55ed9af9f73f38250296","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne.","test_object_en":"Electrical, telecommunications and electronic products and equipment.","methodology":"Odporność na serie szybkich elektrycznych stanów przejściowych Przyłącze sygnałowe i sterujące Zakres: do 2 kV","methodology_en":"Immunity to electrical fast transient/burst Signal and control port Range: up to 2 kV","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na serie szybkich elektrycznych stanów przejściowych Przyłącze sygnałowe i sterujące Zakres: do 2 kV","reference":"PN-EN 61000-4-4:2013-05","norm_bases":["PN-EN 61000-4-4:2013-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Odporność na serie szybkich elektrycznych stanów przejściowych Przyłącze sygnałowe i sterujące Zakres: do 2 kV PN-EN 61000-4-4:2013-05 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne. Odpornosc na serie szybkich elektrycznych stanow przejsciowych Przylacze sygnalowe i sterujace Zakres: do 2 kV PN-EN 61000-4-4:2013-05","categories":["electronics"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical, telecommunications and electronic products and equipment. Immunity to electrical fast transient/burst Signal and control port Range: up to 2 kV PN-EN 61000-4-4:2013-05","search_zh":"电气、电信与电子产品及装备。 PN-EN 61000-4-4:2013-05","test_object_zh":"电气、电信与电子产品及装备。"},{"_id":"6a5a55ed9af9f73f38250297","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne.","test_object_en":"Electrical, telecommunications and electronic products and equipment.","methodology":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia Zakresy: Zapady napięcia: 0 %, 40 %, 70 %, 80 % Zaniki napięcia: 0%","methodology_en":"Immunity to voltage dips, short interruptions and voltage variations Ranges: Voltage dips: 0 %, 40 %, 70 %, 80 % Voltage interruptions: 0%","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia Zakresy: Zapady napięcia: 0 %, 40 %, 70 %, 80 % Zaniki napięcia: 0%","reference":"PN-EN 61000-4-11:2020-11","norm_bases":["PN-EN 61000-4-11:2020-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Odporność na zapady napięcia, krótkie przerwy i zmiany napięcia Zakresy: Zapady napięcia: 0 %, 40 %, 70 %, 80 % Zaniki napięcia: 0% PN-EN 61000-4-11:2020-11 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne. Odpornosc na zapady napiecia, krotkie przerwy i zmiany napiecia Zakresy: Zapady napiecia: 0 %, 40 %, 70 %, 80 % Zaniki napiecia: 0% PN-EN 61000-4-11:2020-11","categories":["electronics"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical, telecommunications and electronic products and equipment. Immunity to voltage dips, short interruptions and voltage variations Ranges: Voltage dips: 0 %, 40 %, 70 %, 80 % Voltage interruptions: 0% PN-EN 61000-4-11:2020-11","search_zh":"电气、电信与电子产品及装备。 PN-EN 61000-4-11:2020-11","test_object_zh":"电气、电信与电子产品及装备。"},{"_id":"6a5a55ed9af9f73f38250298","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Military equipment. Electrical, telecommunication and electronic products and equipment","methodology":"Rezystancja izolacji elektrycznej Zakresy: R= od 50 kΩ do 200 GΩ U = (10 – 1000) V pom DC","methodology_en":"Electrical insulation resistance Ranges: R= from 50 kΩ to 200 GΩ U = (10 – 1000) V meas. DC","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezystancja izolacji elektrycznej Zakresy: R= od 50 kΩ do 200 GΩ U = (10 – 1000) V pom DC","reference":"NO-06-A108:2005, p. 3.2 NO-06-A108:2021, p. 3.2","norm_bases":["NO-06-A108:2005, p. 3.2 NO-06-A108:2021, p. 3.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Rezystancja izolacji elektrycznej Zakresy: R= od 50 kΩ do 200 GΩ U = (10 – 1000) V pom DC NO-06-A108:2005, p. 3.2 NO-06-A108:2021, p. 3.2 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Rezystancja izolacji elektrycznej Zakresy: R= od 50 kΩ do 200 GΩ U = (10 – 1000) V pom DC NO-06-A108:2005, p. 3.2 NO-06-A108:2021, p. 3.2","categories":["construction","electronics"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunication and electronic products and equipment Electrical insulation resistance Ranges: R= from 50 kΩ to 200 GΩ U = (10 – 1000) V meas. DC NO-06-A108:2005, p. 3.2 NO-06-A108:2021, p. 3.2"},{"_id":"6a5a55ed9af9f73f38250299","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Military equipment. Electrical, telecommunication and electronic products and equipment","methodology":"Wytrzymałość elektryczna izolacji Zakresy: U = (0 - 5) kV p AC U = (0 - 6) kV p DC","methodology_en":"Electric strength of the insulation Ranges: U = (0 - 5) kV p AC U = (0 - 6) kV p DC","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość elektryczna izolacji Zakresy: U = (0 - 5) kV p AC U = (0 - 6) kV p DC","reference":"NO-06-A108:2005, p. 3.3 NO-06-A108:2021, p. 3.3","norm_bases":["NO-06-A108:2005, p. 3.3 NO-06-A108:2021, p. 3.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Wytrzymałość elektryczna izolacji Zakresy: U = (0 - 5) kV p AC U = (0 - 6) kV p DC NO-06-A108:2005, p. 3.3 NO-06-A108:2021, p. 3.3 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Wytrzymalosc elektryczna izolacji Zakresy: U = (0 - 5) kV p AC U = (0 - 6) kV p DC NO-06-A108:2005, p. 3.3 NO-06-A108:2021, p. 3.3","categories":["construction","electronics"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunication and electronic products and equipment Electric strength of the insulation Ranges: U = (0 - 5) kV p AC U = (0 - 6) kV p DC NO-06-A108:2005, p. 3.3 NO-06-A108:2021, p. 3.3"},{"_id":"6a5a55ed9af9f73f3825029a","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej","methodology_en":"Immunity to power-frequency magnetic field","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej","reference":"PN-EN 61000-4-8:2010","norm_bases":["PN-EN 61000-4-8:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Odporność na pole magnetyczne o częstotliwości sieci elektroenergetycznej PN-EN 61000-4-8:2010 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Odpornosc na pole magnetyczne o czestotliwosci sieci elektroenergetycznej PN-EN 61000-4-8:2010","categories":["electronics"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical, telecommunications and electronic products and equipment Immunity to power-frequency magnetic field PN-EN 61000-4-8:2010","search_zh":"电气、电信与电子产品及设备 工频磁场抗扰度 PN-EN 61000-4-8:2010","test_object_zh":"电气、电信与电子产品及设备","methodology_zh":"工频磁场抗扰度"},{"_id":"6a5a55ed9af9f73f3825029b","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Poziomy dopuszczalne emisji harmonicznych prądu","methodology_en":"Permissible levels of current harmonic emissions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziomy dopuszczalne emisji harmonicznych prądu","reference":"PN-EN IEC 61000-3-2:2019-04 PN-EN IEC 61000-3-12:2012 PN-EN 61000-3-12:2012/A1:2024-11","norm_bases":["PN-EN IEC 61000-3-2:2019-04 PN-EN IEC 61000-3-12:2012 PN-EN 61000-3-12:2012/A1:2024-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Poziomy dopuszczalne emisji harmonicznych prądu PN-EN IEC 61000-3-2:2019-04 PN-EN IEC 61000-3-12:2012 PN-EN 61000-3-12:2012/A1:2024-11 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Poziomy dopuszczalne emisji harmonicznych pradu PN-EN IEC 61000-3-2:2019-04 PN-EN IEC 61000-3-12:2012 PN-EN 61000-3-12:2012/A1:2024-11","categories":["environment","electronics"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical, telecommunications and electronic products and equipment Permissible levels of current harmonic emissions PN-EN IEC 61000-3-2:2019-04 PN-EN IEC 61000-3-12:2012 PN-EN 61000-3-12:2012/A1:2024-11","search_zh":"电气、电信与电子产品及设备 PN-EN IEC 61000-3-2:2019-04 PN-EN IEC 61000-3-12:2012 PN-EN 61000-3-12:2012/A1:2024-11","test_object_zh":"电气、电信与电子产品及设备"},{"_id":"6a5a55ed9af9f73f3825029c","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne","test_object_en":"Electrical, telecommunications and electronic products and equipment","methodology":"Wahania napięcia i migotanie światła w publicznych sieciach zasilających niskiego napięcia, powodowanych przez odbiorniki o fazowym prądzie znamionowym 32 A","methodology_en":"Voltage fluctuations and flicker in public low-voltage supply systems, caused by equipment with rated phase current 32 A","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wahania napięcia i migotanie światła w publicznych sieciach zasilających niskiego napięcia, powodowanych przez odbiorniki o fazowym prądzie znamionowym 32 A","reference":"PN-EN 61000-3-3:2013-10 PN-EN 61000-3-11:2020","norm_bases":["PN-EN 61000-3-3:2013-10 PN-EN 61000-3-11:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Wahania napięcia i migotanie światła w publicznych sieciach zasilających niskiego napięcia, powodowanych przez odbiorniki o fazowym prądzie znamionowym 32 A PN-EN 61000-3-3:2013-10 PN-EN 61000-3-11:2020 Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Wahania napiecia i migotanie swiatla w publicznych sieciach zasilajacych niskiego napiecia, powodowanych przez odbiorniki o fazowym pradzie znamionowym 32 A PN-EN 61000-3-3:2013-10 PN-EN 61000-3-11:2020","categories":["electronics"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Electrical, telecommunications and electronic products and equipment Voltage fluctuations and flicker in public low-voltage supply systems, caused by equipment with rated phase current 32 A PN-EN 61000-3-3:2013-10 PN-EN 61000-3-11:2020","search_zh":"电气、电信与电子产品及设备 PN-EN 61000-3-3:2013-10 PN-EN 61000-3-11:2020","test_object_zh":"电气、电信与电子产品及设备"},{"_id":"6a5a55ed9af9f73f3825029d","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne. Obiekty o gabarytach do 75 cm x 120 cm x 85 cm","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm","methodology":"Wytrzymałość, odporność, odporność całkowita na obniżoną temperaturę Zakres: Temperatura minimalna -60 °C.","methodology_en":"Strength, resistance and overall resistance to low temperature Range: Minimum temperature -60 °C.","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość, odporność, odporność całkowita na obniżoną temperaturę Zakres: Temperatura minimalna -60 °C.","reference":"PN-EN 60068-2-1: 2009 NO-06-A107:2005, p. 4.3, 5.6 NO-06-A107:2021, p. 4.3, 5.6 MIL-STD 810F, Metoda 502.4, procedury I i II","norm_bases":["PN-EN 60068-2-1: 2009 NO-06-A107:2005, p. 4.3, 5.6 NO-06-A107:2021, p. 4.3, 5.6 MIL-STD 810F, Metoda 502.4, procedury I i II"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne. Obiekty o gabarytach do 75 cm x 120 cm x 85 cm Wytrzymałość, odporność, odporność całkowita na obniżoną temperaturę Zakres: Temperatura minimalna -60 °C. PN-EN 60068-2-1: 2009 NO-06-A107:2005, p. 4.3, 5.6 NO-06-A107:2021, p. 4.3, 5.6 MIL-STD 810F, Metoda 502.4, procedury I i II Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Podzespoly, gotowe wyroby elektrotechniczne i elektroniczne. Obiekty o gabarytach do 75 cm x 120 cm x 85 cm Wytrzymalosc, odpornosc, odpornosc calkowita na obnizona temperature Zakres: Temperatura minimalna -60 °C. PN-EN 60068-2-1: 2009 NO-06-A107:2005, p. 4.3, 5.6 NO-06-A107:2021, p. 4.3, 5.6 MIL-STD 810F, Metoda 502.4, procedury I i II","categories":["electronics"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm Strength, resistance and overall resistance to low temperature Range: Minimum temperature -60 °C. PN-EN 60068-2-1: 2009 NO-06-A107:2005, p. 4.3, 5.6 NO-06-A107:2021, p. 4.3, 5.6 MIL-STD 810F, Metoda 502.4, procedury I i II","search_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。外形尺寸至 75 cm x 120 cm x 85 cm 的对象 PN-EN 60068-2-1: 2009 NO-06-A107:2005, p. 4.3, 5.6 NO-06-A107:2021, p. 4.3, 5.6 MIL-STD 810F, Metoda 502.4, procedury I i II","test_object_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。外形尺寸至 75 cm x 120 cm x 85 cm 的对象"},{"_id":"6a5a55ed9af9f73f3825029e","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne. Obiekty o gabarytach do 75 cm x 120 cm x 85 cm","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm","methodology":"Wytrzymałość, odporność, odporność całkowita na podwyższoną temperaturę Zakres: temperatura maksymalna +170 °C, wilgotność względna minimalna 20 %.","methodology_en":"Strength, resistance and overall resistance to elevated temperature Range: maximum temperature +170 °C, minimum relative humidity 20 %.","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość, odporność, odporność całkowita na podwyższoną temperaturę Zakres: temperatura maksymalna +170 °C, wilgotność względna minimalna 20 %.","reference":"PN-EN 60068-2-2:2009 NO-06-A107:2005, p. 4.2, 5.7 NO-06-A107:2021, p. 4.2, 5.7 MIL-STD 810F, Metoda 501.4, procedury I i II","norm_bases":["PN-EN 60068-2-2:2009 NO-06-A107:2005, p. 4.2, 5.7 NO-06-A107:2021, p. 4.2, 5.7 MIL-STD 810F, Metoda 501.4, procedury I i II"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne. Obiekty o gabarytach do 75 cm x 120 cm x 85 cm Wytrzymałość, odporność, odporność całkowita na podwyższoną temperaturę Zakres: temperatura maksymalna +170 °C, wilgotność względna minimalna 20 %. PN-EN 60068-2-2:2009 NO-06-A107:2005, p. 4.2, 5.7 NO-06-A107:2021, p. 4.2, 5.7 MIL-STD 810F, Metoda 501.4, procedury I i II Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Podzespoly, gotowe wyroby elektrotechniczne i elektroniczne. Obiekty o gabarytach do 75 cm x 120 cm x 85 cm Wytrzymalosc, odpornosc, odpornosc calkowita na podwyzszona temperature Zakres: temperatura maksymalna +170 °C, wilgotnosc wzgledna minimalna 20 %. PN-EN 60068-2-2:2009 NO-06-A107:2005, p. 4.2, 5.7 NO-06-A107:2021, p. 4.2, 5.7 MIL-STD 810F, Metoda 501.4, procedury I i II","categories":["electronics"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm Strength, resistance and overall resistance to elevated temperature Range: maximum temperature +170 °C, minimum relative humidity 20 %. PN-EN 60068-2-2:2009 NO-06-A107:2005, p. 4.2, 5.7 NO-06-A107:2021, p. 4.2, 5.7 MIL-STD 810F, Metoda 501.4, procedury I i II","search_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。外形尺寸至 75 cm x 120 cm x 85 cm 的对象 PN-EN 60068-2-2:2009 NO-06-A107:2005, p. 4.2, 5.7 NO-06-A107:2021, p. 4.2, 5.7 MIL-STD 810F, Metoda 501.4, procedury I i II","test_object_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。外形尺寸至 75 cm x 120 cm x 85 cm 的对象"},{"_id":"6a5a55ed9af9f73f3825029f","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne. Obiekty o gabarytach do 75 cm x 120 cm x 85 cm","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm","methodology":"Wytrzymałość, odporność, odporność całkowita na wilgotne gorąco stałe/cykliczne Zakres: wilgotność względna do 95 % temp. od +20 °C do +85 °C","methodology_en":"Strength, resistance and overall resistance to damp heat, steady state/cyclic Range: relative humidity up to 95 % temp. from +20 °C to +85 °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość, odporność, odporność całkowita na wilgotne gorąco stałe/cykliczne Zakres: wilgotność względna do 95 % temp. od +20 °C do +85 °C","reference":"PN-EN 60068-2-30:2008 PN-EN 60068-2-78:2013-11 NO-06-A107:2005, p. 4.4, Metoda 1, 2 i Metoda 3, p.5.10 NO-06-A107:2021, p. 4.4, Metoda 1, 2 i Metoda 3, p.5.10 MIL-STD 810F, Metoda 507.4","norm_bases":["PN-EN 60068-2-30:2008 PN-EN 60068-2-78:2013-11 NO-06-A107:2005, p. 4.4, Metoda 1, 2 i Metoda 3, p.5.10 NO-06-A107:2021, p. 4.4, Metoda 1, 2 i Metoda 3, p.5.10 MIL-STD 810F, Metoda 507.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne. Obiekty o gabarytach do 75 cm x 120 cm x 85 cm Wytrzymałość, odporność, odporność całkowita na wilgotne gorąco stałe/cykliczne Zakres: wilgotność względna do 95 % temp. od +20 °C do +85 °C PN-EN 60068-2-30:2008 PN-EN 60068-2-78:2013-11 NO-06-A107:2005, p. 4.4, Metoda 1, 2 i Metoda 3, p.5.10 NO-06-A107:2021, p. 4.4, Metoda 1, 2 i Metoda 3, p.5.10 MIL-STD 810F, Metoda 507.4 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Podzespoly, gotowe wyroby elektrotechniczne i elektroniczne. Obiekty o gabarytach do 75 cm x 120 cm x 85 cm Wytrzymalosc, odpornosc, odpornosc calkowita na wilgotne goraco stale/cykliczne Zakres: wilgotnosc wzgledna do 95 % temp. od +20 °C do +85 °C PN-EN 60068-2-30:2008 PN-EN 60068-2-78:2013-11 NO-06-A107:2005, p. 4.4, Metoda 1, 2 i Metoda 3, p.5.10 NO-06-A107:2021, p. 4.4, Metoda 1, 2 i Metoda 3, p.5.10 MIL-STD 810F, Metoda 507.4","categories":["electronics"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm Strength, resistance and overall resistance to damp heat, steady state/cyclic Range: relative humidity up to 95 % temp. from +20 °C to +85 °C PN-EN 60068-2-30:2008 PN-EN 60068-2-78:2013-11 NO-06-A107:2005, p. 4.4, Metoda 1, 2 i Metoda 3, p.5.10 NO-06-A107:2021, p. 4.4, Metoda 1, 2 i Metoda 3, p.5.10 MIL-STD 810F, Metoda 507.4","search_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。外形尺寸至 75 cm x 120 cm x 85 cm 的对象 PN-EN 60068-2-30:2008 PN-EN 60068-2-78:2013-11 NO-06-A107:2005, p. 4.4, Metoda 1, 2 i Metoda 3, p.5.10 NO-06-A107:2021, p. 4.4, Metoda 1, 2 i Metoda 3, p.5.10 MIL-STD 810F, Metoda 507.4","test_object_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。外形尺寸至 75 cm x 120 cm x 85 cm 的对象"},{"_id":"6a5a55ed9af9f73f382502a0","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne. Obiekty o gabarytach do 75 cm x 120 cm x 85 cm","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm","methodology":"Wytrzymałość i odporność na zmiany temperatury Zakres: temp. min. -60 °C, temp. max. +170 °C. Metoda: jednej komory.","methodology_en":"Strength and resistance to temperature changes Range: min. temp. -60 °C, max. temp. +170 °C. Method: one chamber.","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość i odporność na zmiany temperatury Zakres: temp. min. -60 °C, temp. max. +170 °C. Metoda: jednej komory.","reference":"PN-EN IEC 60068-2-14:2024-04, próba Nb PN-EN 60068-2-14:2009, próba Nb NO-06-A107:2005, p. 4.5, Metoda 2, p. 5.9 NO-06-A107:2021, p. 4.5, Metoda 2, p. 5.9","norm_bases":["PN-EN IEC 60068-2-14:2024-04, próba Nb PN-EN 60068-2-14:2009, próba Nb NO-06-A107:2005, p. 4.5, Metoda 2, p. 5.9 NO-06-A107:2021, p. 4.5, Metoda 2, p. 5.9"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne. Obiekty o gabarytach do 75 cm x 120 cm x 85 cm Wytrzymałość i odporność na zmiany temperatury Zakres: temp. min. -60 °C, temp. max. +170 °C. Metoda: jednej komory. PN-EN IEC 60068-2-14:2024-04, próba Nb PN-EN 60068-2-14:2009, próba Nb NO-06-A107:2005, p. 4.5, Metoda 2, p. 5.9 NO-06-A107:2021, p. 4.5, Metoda 2, p. 5.9 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Podzespoly, gotowe wyroby elektrotechniczne i elektroniczne. Obiekty o gabarytach do 75 cm x 120 cm x 85 cm Wytrzymalosc i odpornosc na zmiany temperatury Zakres: temp. min. -60 °C, temp. max. +170 °C. Metoda: jednej komory. PN-EN IEC 60068-2-14:2024-04, proba Nb PN-EN 60068-2-14:2009, proba Nb NO-06-A107:2005, p. 4.5, Metoda 2, p. 5.9 NO-06-A107:2021, p. 4.5, Metoda 2, p. 5.9","categories":["electronics"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm Strength and resistance to temperature changes Range: min. temp. -60 °C, max. temp. +170 °C. Method: one chamber. PN-EN IEC 60068-2-14:2024-04, próba Nb PN-EN 60068-2-14:2009, próba Nb NO-06-A107:2005, p. 4.5, Metoda 2, p. 5.9 NO-06-A107:2021, p. 4.5, Metoda 2, p. 5.9","search_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。外形尺寸至 75 cm x 120 cm x 85 cm 的对象 PN-EN IEC 60068-2-14:2024-04, próba Nb PN-EN 60068-2-14:2009, próba Nb NO-06-A107:2005, p. 4.5, Metoda 2, p. 5.9 NO-06-A107:2021, p. 4.5, Metoda 2, p. 5.9","test_object_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。外形尺寸至 75 cm x 120 cm x 85 cm 的对象"},{"_id":"6a5a55ed9af9f73f382502a1","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne. Obiekty o gabarytach do 75 cm x 120 cm x 85 cm","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm","methodology":"Wytrzymałość i odporność na zmiany temperatury Zakres: temp. min. -60 °C, temp. maks. +170 °C. Metoda: dwóch komór","methodology_en":"Strength and resistance to temperature changes Range: min. temp. -60 °C, max. temp. +170 °C. Method: two chambers","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość i odporność na zmiany temperatury Zakres: temp. min. -60 °C, temp. maks. +170 °C. Metoda: dwóch komór","reference":"PN-EN IEC 60068-2-14:2024-04, próba Na PN-EN 60068-2-14:2009, próba Na NO-06-A107:2005, p. 4.5, Metoda 1, p.5.8 NO-06-A107:2021, p. 4.5, Metoda 1, p.5.8 MIL-STD 810F, Metoda 503.4, procedury I i II","norm_bases":["PN-EN IEC 60068-2-14:2024-04, próba Na PN-EN 60068-2-14:2009, próba Na NO-06-A107:2005, p. 4.5, Metoda 1, p.5.8 NO-06-A107:2021, p. 4.5, Metoda 1, p.5.8 MIL-STD 810F, Metoda 503.4, procedury I i II"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne. Obiekty o gabarytach do 75 cm x 120 cm x 85 cm Wytrzymałość i odporność na zmiany temperatury Zakres: temp. min. -60 °C, temp. maks. +170 °C. Metoda: dwóch komór PN-EN IEC 60068-2-14:2024-04, próba Na PN-EN 60068-2-14:2009, próba Na NO-06-A107:2005, p. 4.5, Metoda 1, p.5.8 NO-06-A107:2021, p. 4.5, Metoda 1, p.5.8 MIL-STD 810F, Metoda 503.4, procedury I i II Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Podzespoly, gotowe wyroby elektrotechniczne i elektroniczne. Obiekty o gabarytach do 75 cm x 120 cm x 85 cm Wytrzymalosc i odpornosc na zmiany temperatury Zakres: temp. min. -60 °C, temp. maks. +170 °C. Metoda: dwoch komor PN-EN IEC 60068-2-14:2024-04, proba Na PN-EN 60068-2-14:2009, proba Na NO-06-A107:2005, p. 4.5, Metoda 1, p.5.8 NO-06-A107:2021, p. 4.5, Metoda 1, p.5.8 MIL-STD 810F, Metoda 503.4, procedury I i II","categories":["electronics"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm Strength and resistance to temperature changes Range: min. temp. -60 °C, max. temp. +170 °C. Method: two chambers PN-EN IEC 60068-2-14:2024-04, próba Na PN-EN 60068-2-14:2009, próba Na NO-06-A107:2005, p. 4.5, Metoda 1, p.5.8 NO-06-A107:2021, p. 4.5, Metoda 1, p.5.8 MIL-STD 810F, Metoda 503.4, procedury I i II","search_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。外形尺寸至 75 cm x 120 cm x 85 cm 的对象 PN-EN IEC 60068-2-14:2024-04, próba Na PN-EN 60068-2-14:2009, próba Na NO-06-A107:2005, p. 4.5, Metoda 1, p.5.8 NO-06-A107:2021, p. 4.5, Metoda 1, p.5.8 MIL-STD 810F, Metoda 503.4, procedury I i II","test_object_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。外形尺寸至 75 cm x 120 cm x 85 cm 的对象"},{"_id":"6a5a55ed9af9f73f382502a2","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne. Obiekty o gabarytach do 75 cm x 120 cm x 85 cm","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm","methodology":"Odporność na kondensacyjne osady atmosferyczne (szron i rosę)","methodology_en":"Resistance to condensation atmospheric deposits (frost and dew)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na kondensacyjne osady atmosferyczne (szron i rosę)","reference":"NO-06–A107:2005, p 4.10. NO-06–A107:2021, p 4.10.","norm_bases":["NO-06–A107:2005, p 4.10. NO-06–A107:2021, p 4.10."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne. Obiekty o gabarytach do 75 cm x 120 cm x 85 cm Odporność na kondensacyjne osady atmosferyczne (szron i rosę) NO-06–A107:2005, p 4.10. NO-06–A107:2021, p 4.10. Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Podzespoly, gotowe wyroby elektrotechniczne i elektroniczne. Obiekty o gabarytach do 75 cm x 120 cm x 85 cm Odpornosc na kondensacyjne osady atmosferyczne (szron i rose) NO-06–A107:2005, p 4.10. NO-06–A107:2021, p 4.10.","categories":["water","electronics"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Objects with dimensions up to 75 cm x 120 cm x 85 cm Resistance to condensation atmospheric deposits (frost and dew) NO-06–A107:2005, p 4.10. NO-06–A107:2021, p 4.10.","search_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。外形尺寸至 75 cm x 120 cm x 85 cm 的对象 NO-06–A107:2005, p 4.10. NO-06–A107:2021, p 4.10.","test_object_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。外形尺寸至 75 cm x 120 cm x 85 cm 的对象"},{"_id":"6a5a55ed9af9f73f382502a3","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products.","methodology":"Rezonanse mechaniczne konstrukcji. Zakres: częstotliwość: (5 – 40) Hz.","methodology_en":"Mechanical resonances of the structure. Range: frequency: (5 – 40) Hz.","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Rezonanse mechaniczne konstrukcji. Zakres: częstotliwość: (5 – 40) Hz.","reference":"NO-06-A107:2005, p. 2.2 NO-06-A107:2021, p. 2.2","norm_bases":["NO-06-A107:2005, p. 2.2 NO-06-A107:2021, p. 2.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne. Rezonanse mechaniczne konstrukcji. Zakres: częstotliwość: (5 – 40) Hz. NO-06-A107:2005, p. 2.2 NO-06-A107:2021, p. 2.2 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Podzespoly, gotowe wyroby elektrotechniczne i elektroniczne. Rezonanse mechaniczne konstrukcji. Zakres: czestotliwosc: (5 – 40) Hz. NO-06-A107:2005, p. 2.2 NO-06-A107:2021, p. 2.2","categories":["electronics"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Mechanical resonances of the structure. Range: frequency: (5 – 40) Hz. NO-06-A107:2005, p. 2.2 NO-06-A107:2021, p. 2.2","search_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。 NO-06-A107:2005, p. 2.2 NO-06-A107:2021, p. 2.2","test_object_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。"},{"_id":"6a5a55ed9af9f73f382502a4","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products.","methodology":"Wytrzymałość, odporność, odporność całkowita na wibracje mechaniczne sinusoidalne Zakresy: Częstotliwość: (1 – 3000) Hz","methodology_en":"Strength, resistance and overall resistance to sinusoidal mechanical vibration Ranges: Frequency: (1 – 3000) Hz","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość, odporność, odporność całkowita na wibracje mechaniczne sinusoidalne Zakresy: Częstotliwość: (1 – 3000) Hz","reference":"PN-EN 60068-2-6:2008 NO-06-A107:2005, p. 2.3, 2.7, 2.12, 3.2 NO-06-A107:2021, p. 2.3, 2.7, 2.12, 3.2 MIL-STD 810F, Metoda 514.5, procedura I","norm_bases":["PN-EN 60068-2-6:2008 NO-06-A107:2005, p. 2.3, 2.7, 2.12, 3.2 NO-06-A107:2021, p. 2.3, 2.7, 2.12, 3.2 MIL-STD 810F, Metoda 514.5, procedura I"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne. Wytrzymałość, odporność, odporność całkowita na wibracje mechaniczne sinusoidalne Zakresy: Częstotliwość: (1 – 3000) Hz PN-EN 60068-2-6:2008 NO-06-A107:2005, p. 2.3, 2.7, 2.12, 3.2 NO-06-A107:2021, p. 2.3, 2.7, 2.12, 3.2 MIL-STD 810F, Metoda 514.5, procedura I Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Podzespoly, gotowe wyroby elektrotechniczne i elektroniczne. Wytrzymalosc, odpornosc, odpornosc calkowita na wibracje mechaniczne sinusoidalne Zakresy: Czestotliwosc: (1 – 3000) Hz PN-EN 60068-2-6:2008 NO-06-A107:2005, p. 2.3, 2.7, 2.12, 3.2 NO-06-A107:2021, p. 2.3, 2.7, 2.12, 3.2 MIL-STD 810F, Metoda 514.5, procedura I","categories":["electronics"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Strength, resistance and overall resistance to sinusoidal mechanical vibration Ranges: Frequency: (1 – 3000) Hz PN-EN 60068-2-6:2008 NO-06-A107:2005, p. 2.3, 2.7, 2.12, 3.2 NO-06-A107:2021, p. 2.3, 2.7, 2.12, 3.2 MIL-STD 810F, Metoda 514.5, procedura I","search_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。 PN-EN 60068-2-6:2008 NO-06-A107:2005, p. 2.3, 2.7, 2.12, 3.2 NO-06-A107:2021, p. 2.3, 2.7, 2.12, 3.2 MIL-STD 810F, Metoda 514.5, procedura I","test_object_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。"},{"_id":"6a5a55ed9af9f73f382502a5","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products.","methodology":"Wytrzymałość, odporność, odporność całkowita na udary mechaniczne (półsinusoida / trapez). Zakresy: Amplituda szczytowego przyśpieszenia odpowiednio do 1500 m/s² Czas trwania udaru: (1 - 50) ms. Częstotliwość powtarzania do 3 Hz.","methodology_en":"Strength, resistance and overall resistance to mechanical shocks (half-sine / trapezoid). Ranges: Peak acceleration amplitude up to 1500 m/s² respectively Shock duration: (1 - 50) ms. Repetition frequency up to 3 Hz.","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość, odporność, odporność całkowita na udary mechaniczne (półsinusoida / trapez). Zakresy: Amplituda szczytowego przyśpieszenia odpowiednio do 1500 m/s² Czas trwania udaru: (1 - 50) ms. Częstotliwość powtarzania do 3 Hz.","reference":"PN-EN 60068-2-27:2009 NO-06-A107:2005, p. 2.5, 2.9, 2.13, 3.4 NO-06-A107:2021, p. 2.5, 2.9, 2.13, 3.4","norm_bases":["PN-EN 60068-2-27:2009 NO-06-A107:2005, p. 2.5, 2.9, 2.13, 3.4 NO-06-A107:2021, p. 2.5, 2.9, 2.13, 3.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne. Wytrzymałość, odporność, odporność całkowita na udary mechaniczne (półsinusoida / trapez). Zakresy: Amplituda szczytowego przyśpieszenia odpowiednio do 1500 m/s² Czas trwania udaru: (1 - 50) ms. Częstotliwość powtarzania do 3 Hz. PN-EN 60068-2-27:2009 NO-06-A107:2005, p. 2.5, 2.9, 2.13, 3.4 NO-06-A107:2021, p. 2.5, 2.9, 2.13, 3.4 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Podzespoly, gotowe wyroby elektrotechniczne i elektroniczne. Wytrzymalosc, odpornosc, odpornosc calkowita na udary mechaniczne (polsinusoida / trapez). Zakresy: Amplituda szczytowego przyspieszenia odpowiednio do 1500 m/s² Czas trwania udaru: (1 - 50) ms. Czestotliwosc powtarzania do 3 Hz. PN-EN 60068-2-27:2009 NO-06-A107:2005, p. 2.5, 2.9, 2.13, 3.4 NO-06-A107:2021, p. 2.5, 2.9, 2.13, 3.4","categories":["electronics"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Strength, resistance and overall resistance to mechanical shocks (half-sine / trapezoid). Ranges: Peak acceleration amplitude up to 1500 m/s² respectively Shock duration: (1 - 50) ms. Repetition frequency up to 3 Hz. PN-EN 60068-2-27:2009 NO-06-A107:2005, p. 2.5, 2.9, 2.13, 3.4 NO-06-A107:2021, p. 2.5, 2.9, 2.13, 3.4","search_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。 PN-EN 60068-2-27:2009 NO-06-A107:2005, p. 2.5, 2.9, 2.13, 3.4 NO-06-A107:2021, p. 2.5, 2.9, 2.13, 3.4","test_object_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。"},{"_id":"6a5a55ed9af9f73f382502a6","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products.","methodology":"Wytrzymałość, odporność, odporność całkowita na wibracje przypadkowe szerokopasmowe Częstotliwość (10 – 2000) Hz Wartość średnia kwadratowa G do RMS 30 g . n","methodology_en":"Strength, resistance and overall resistance to broadband random vibration Frequency (10 – 2000) Hz Root mean square value G up to RMS 30 g . n","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość, odporność, odporność całkowita na wibracje przypadkowe szerokopasmowe Częstotliwość (10 – 2000) Hz Wartość średnia kwadratowa G do RMS 30 g . n","reference":"PN-EN 60068-2-64:2008 NO-06-A107:2005 | NO-06-A107 | MIL-STD-","norm_bases":["PN-EN 60068-2-64:2008 NO-06-A107:2005","NO-06-A107","MIL-STD-"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne. Wytrzymałość, odporność, odporność całkowita na wibracje przypadkowe szerokopasmowe Częstotliwość (10 – 2000) Hz Wartość średnia kwadratowa G do RMS 30 g . n PN-EN 60068-2-64:2008 NO-06-A107:2005 | NO-06-A107 | MIL-STD- Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Podzespoly, gotowe wyroby elektrotechniczne i elektroniczne. Wytrzymalosc, odpornosc, odpornosc calkowita na wibracje przypadkowe szerokopasmowe Czestotliwosc (10 – 2000) Hz Wartosc srednia kwadratowa G do RMS 30 g . n PN-EN 60068-2-64:2008 NO-06-A107:2005 | NO-06-A107 | MIL-STD-","categories":["electronics"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Strength, resistance and overall resistance to broadband random vibration Frequency (10 – 2000) Hz Root mean square value G up to RMS 30 g . n PN-EN 60068-2-64:2008 NO-06-A107:2005 | NO-06-A107 | MIL-STD-","search_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。 PN-EN 60068-2-64:2008 NO-06-A107:2005 | NO-06-A107 | MIL-STD-","test_object_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。"},{"_id":"6a5a55ed9af9f73f382502a7","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products.","methodology":"Wytrzymałość i odporność całkowita na transport","methodology_en":"Overall strength and resistance to transport","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość i odporność całkowita na transport","reference":"NO-06-A107:2005, p 2.10 NO-06-A107:2021, p 2.10","norm_bases":["NO-06-A107:2005, p 2.10 NO-06-A107:2021, p 2.10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne. Wytrzymałość i odporność całkowita na transport NO-06-A107:2005, p 2.10 NO-06-A107:2021, p 2.10 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Podzespoly, gotowe wyroby elektrotechniczne i elektroniczne. Wytrzymalosc i odpornosc calkowita na transport NO-06-A107:2005, p 2.10 NO-06-A107:2021, p 2.10","categories":["electronics"],"row_index":43,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Overall strength and resistance to transport NO-06-A107:2005, p 2.10 NO-06-A107:2021, p 2.10","search_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。 NO-06-A107:2005, p 2.10 NO-06-A107:2021, p 2.10","test_object_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。"},{"_id":"6a5a55ed9af9f73f382502a8","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne.","test_object_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products.","methodology":"Wytrzymałość na spadki swobodne, upuszczenia, przewrócenia","methodology_en":"Resistance to free falls, drops and topples","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość na spadki swobodne, upuszczenia, przewrócenia","reference":"PN-EN 60068-2-31:2010 NO-06-A107:2005, p. 2.11 NO-06-A107:2021, p. 2.11 MIL-STD 810F, Metoda 516.5, procedura IV","norm_bases":["PN-EN 60068-2-31:2010 NO-06-A107:2005, p. 2.11 NO-06-A107:2021, p. 2.11 MIL-STD 810F, Metoda 516.5, procedura IV"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne Podzespoły, gotowe wyroby elektrotechniczne i elektroniczne. Wytrzymałość na spadki swobodne, upuszczenia, przewrócenia PN-EN 60068-2-31:2010 NO-06-A107:2005, p. 2.11 NO-06-A107:2021, p. 2.11 MIL-STD 810F, Metoda 516.5, procedura IV Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne Podzespoly, gotowe wyroby elektrotechniczne i elektroniczne. Wytrzymalosc na spadki swobodne, upuszczenia, przewrocenia PN-EN 60068-2-31:2010 NO-06-A107:2005, p. 2.11 NO-06-A107:2021, p. 2.11 MIL-STD 810F, Metoda 516.5, procedura IV","categories":["electronics"],"row_index":44,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunications and electronic products and equipment Subassemblies, finished electrotechnical and electronic products. Resistance to free falls, drops and topples PN-EN 60068-2-31:2010 NO-06-A107:2005, p. 2.11 NO-06-A107:2021, p. 2.11 MIL-STD 810F, Metoda 516.5, procedura IV","search_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。 PN-EN 60068-2-31:2010 NO-06-A107:2005, p. 2.11 NO-06-A107:2021, p. 2.11 MIL-STD 810F, Metoda 516.5, procedura IV","test_object_zh":"军用装备。电气、电信与电子产品及装备。组件、成品电工与电子制品。"},{"_id":"6a5a55ed9af9f73f382502a9","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Obudowy urządzeń elektrycznych i elektronicznych. Gabaryty obiektów: - przekrój poziomy Ǿ50 cm.","test_object_en":"Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Object dimensions: - horizontal cross-section Ǿ50 cm.","methodology":"Hermetyczność. Wytrzymałość na zanurzanie w wodzie Kod IPX7 – IPX8","methodology_en":"Tightness. Resistance to immersion in water Code IPX7 – IPX8","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Hermetyczność. Wytrzymałość na zanurzanie w wodzie Kod IPX7 – IPX8","reference":"PN-EN 60529:2003, p. 14.2.7 i 14.2.8 NO-06-A107:2005, p. 4.16, Metoda 2 NO-06-A107:2021, p. 4.16, Metoda 2 MIL-STD 810F, Metoda 512.4, procedura I","norm_bases":["PN-EN 60529:2003, p. 14.2.7 i 14.2.8 NO-06-A107:2005, p. 4.16, Metoda 2 NO-06-A107:2021, p. 4.16, Metoda 2 MIL-STD 810F, Metoda 512.4, procedura I"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Obudowy urządzeń elektrycznych i elektronicznych. Gabaryty obiektów: - przekrój poziomy Ǿ50 cm. Hermetyczność. Wytrzymałość na zanurzanie w wodzie Kod IPX7 – IPX8 PN-EN 60529:2003, p. 14.2.7 i 14.2.8 NO-06-A107:2005, p. 4.16, Metoda 2 NO-06-A107:2021, p. 4.16, Metoda 2 MIL-STD 810F, Metoda 512.4, procedura I Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne. Obudowy urzadzen elektrycznych i elektronicznych. Gabaryty obiektow: - przekroj poziomy Ø50 cm. Hermetycznosc. Wytrzymalosc na zanurzanie w wodzie Kod IPX7 – IPX8 PN-EN 60529:2003, p. 14.2.7 i 14.2.8 NO-06-A107:2005, p. 4.16, Metoda 2 NO-06-A107:2021, p. 4.16, Metoda 2 MIL-STD 810F, Metoda 512.4, procedura I","categories":["electronics"],"row_index":45,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Object dimensions: - horizontal cross-section Ǿ50 cm. Tightness. Resistance to immersion in water Code IPX7 – IPX8 PN-EN 60529:2003, p. 14.2.7 i 14.2.8 NO-06-A107:2005, p. 4.16, Metoda 2 NO-06-A107:2021, p. 4.16, Metoda 2 MIL-STD 810F, Metoda 512.4, procedura I"},{"_id":"6a5a55ed9af9f73f382502aa","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Obudowy urządzeń elektrycznych i elektronicznych. Gabaryty obiektów do: 50 cm x 50 cm x 50 cm","test_object_en":"Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Object dimensions up to: 50 cm x 50 cm x 50 cm","methodology":"Bryzgoszczelność Kod IPX3 - IPX4","methodology_en":"Protection against splashing water Code IPX3 - IPX4","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Bryzgoszczelność Kod IPX3 - IPX4","reference":"PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07","norm_bases":["PN-EN 60529:2003","PN-EN 60529:2003/A2:2014-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Obudowy urządzeń elektrycznych i elektronicznych. Gabaryty obiektów do: 50 cm x 50 cm x 50 cm Bryzgoszczelność Kod IPX3 - IPX4 PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne. Obudowy urzadzen elektrycznych i elektronicznych. Gabaryty obiektow do: 50 cm x 50 cm x 50 cm Bryzgoszczelnosc Kod IPX3 - IPX4 PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07","categories":["electronics"],"row_index":46,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Object dimensions up to: 50 cm x 50 cm x 50 cm Protection against splashing water Code IPX3 - IPX4 PN-EN 60529:2003 | PN-EN 60529:2003/A2:2014-07"},{"_id":"6a5a55ed9af9f73f382502ab","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Obudowy urządzeń elektrycznych i elektronicznych. Gabaryty obiektów do: 50 cm x 50 cm x 50 cm","test_object_en":"Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Object dimensions up to: 50 cm x 50 cm x 50 cm","methodology":"Wytrzymałość i odporność na deszcz (kroploszczelność) Kod IPX1 – IPX2","methodology_en":"Strength and resistance to rain (drip-proofness) Code IPX1 – IPX2","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość i odporność na deszcz (kroploszczelność) Kod IPX1 – IPX2","reference":"PN-EN 60529:2003, p. 14.2.1 i p. 14.2.2 PN-EN 60529:2003/A2:2014-07 NO-06-A107:2005, p.4.18 NO-06-A107:2021, p.4.18 MIL-STD 810F, Metoda 506.4, procedura III","norm_bases":["PN-EN 60529:2003, p. 14.2.1 i p. 14.2.2 PN-EN 60529:2003/A2:2014-07 NO-06-A107:2005, p.4.18 NO-06-A107:2021, p.4.18 MIL-STD 810F, Metoda 506.4, procedura III"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Obudowy urządzeń elektrycznych i elektronicznych. Gabaryty obiektów do: 50 cm x 50 cm x 50 cm Wytrzymałość i odporność na deszcz (kroploszczelność) Kod IPX1 – IPX2 PN-EN 60529:2003, p. 14.2.1 i p. 14.2.2 PN-EN 60529:2003/A2:2014-07 NO-06-A107:2005, p.4.18 NO-06-A107:2021, p.4.18 MIL-STD 810F, Metoda 506.4, procedura III Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne. Obudowy urzadzen elektrycznych i elektronicznych. Gabaryty obiektow do: 50 cm x 50 cm x 50 cm Wytrzymalosc i odpornosc na deszcz (kroploszczelnosc) Kod IPX1 – IPX2 PN-EN 60529:2003, p. 14.2.1 i p. 14.2.2 PN-EN 60529:2003/A2:2014-07 NO-06-A107:2005, p.4.18 NO-06-A107:2021, p.4.18 MIL-STD 810F, Metoda 506.4, procedura III","categories":["electronics"],"row_index":47,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Object dimensions up to: 50 cm x 50 cm x 50 cm Strength and resistance to rain (drip-proofness) Code IPX1 – IPX2 PN-EN 60529:2003, p. 14.2.1 i p. 14.2.2 PN-EN 60529:2003/A2:2014-07 NO-06-A107:2005, p.4.18 NO-06-A107:2021, p.4.18 MIL-STD 810F, Metoda 506.4, procedura III"},{"_id":"6a5a55ed9af9f73f382502ac","lab_id":"69ad52a3de79e566650fb5c8","country":"PL","accr_number":"AB 1132","accr_body":"PCA","test_object":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Obudowy urządzeń elektrycznych i elektronicznych. Gabaryty: 67 cm x 67 cm x 20 cm","test_object_en":"Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Dimensions: 67 cm x 67 cm x 20 cm","methodology":"Wytrzymałość i odporność na działanie pyłu (pyłoszczelność) Kod IP5X","methodology_en":"Strength and resistance to dust (dust-tightness) Code IP5X","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wytrzymałość i odporność na działanie pyłu (pyłoszczelność) Kod IP5X","reference":"PN-EN 60529:2003, p. 13.4 i 13.5, kategoria 2 NO-06-A107:2005, p. 4.12, Metoda 2, p.5.15 NO-06-A107:2021, p. 4.12, Metoda 2, p.5.15","norm_bases":["PN-EN 60529:2003, p. 13.4 i 13.5, kategoria 2 NO-06-A107:2005, p. 4.12, Metoda 2, p.5.15 NO-06-A107:2021, p. 4.12, Metoda 2, p.5.15"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe. Wyroby i wyposażenie elektryczne, telekomunikacyjne i elektroniczne. Obudowy urządzeń elektrycznych i elektronicznych. Gabaryty: 67 cm x 67 cm x 20 cm Wytrzymałość i odporność na działanie pyłu (pyłoszczelność) Kod IP5X PN-EN 60529:2003, p. 13.4 i 13.5, kategoria 2 NO-06-A107:2005, p. 4.12, Metoda 2, p.5.15 NO-06-A107:2021, p. 4.12, Metoda 2, p.5.15 Wyposazenie wojskowe. Wyroby i wyposazenie elektryczne, telekomunikacyjne i elektroniczne. Obudowy urzadzen elektrycznych i elektronicznych. Gabaryty: 67 cm x 67 cm x 20 cm Wytrzymalosc i odpornosc na dzialanie pylu (pyloszczelnosc) Kod IP5X PN-EN 60529:2003, p. 13.4 i 13.5, kategoria 2 NO-06-A107:2005, p. 4.12, Metoda 2, p.5.15 NO-06-A107:2021, p. 4.12, Metoda 2, p.5.15","categories":["electronics"],"row_index":48,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Military equipment. Electrical, telecommunication and electronic products and equipment. Enclosures of electrical and electronic equipment. Dimensions: 67 cm x 67 cm x 20 cm Strength and resistance to dust (dust-tightness) Code IP5X PN-EN 60529:2003, p. 13.4 i 13.5, kategoria 2 NO-06-A107:2005, p. 4.12, Metoda 2, p.5.15 NO-06-A107:2021, p. 4.12, Metoda 2, p.5.15"}],"has_pdf":true}