🇵🇱 LABOD Sp. z o.o. PL
EnvironmentConstruction
LABOD Sp. z o.o. is a laboratory accredited by PCA under number AB 1131 (Poland). Its accreditation scope covers 20 test methods in the following areas: Environment, Construction. Test objects include: Workplace environment - air, Workplace environment - energy expenditure, Workplace environment - indoor electric lighting, Workplace environment - noise.
At a glance
- Accreditation number: PCA AB 1131
- Methods in scope: 20
- Types of test objects: 9
- Accreditation number
- AB 1131
- Accreditation body
- PCA
- Address
- Laboratorium Środowiska Pracy, Os. Armii Krajowej 105
- City
- Poland
What this laboratory tests (9)
- Workplace environment - air — 4 methods
- Workplace environment - energy expenditure — 2 methods
- Workplace environment - indoor electric lighting — 2 methods
- Workplace environment - noise — 2 methods
- Workplace environment – cold microclimate — 2 methods
- Workplace environment – hand-arm vibration — 2 methods
- Workplace environment – hot microclimate — 2 methods
- Workplace environment – moderate microclimate — 2 methods
- Workplace environment – whole-body vibration — 2 methods
Accreditation scope — test methods (20)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment - noise | A-weighted equivalent sound level A-weighted maximum sound level C-weighted peak sound level Range: (55 – 138) dB Direct measurement method | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 p. 10 i strategię 3 p. 11 PN-N-01307:1994 | ||
| 2 | Workplace environment - noise | Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated) | |||
| 3 | Workplace environment - indoor electric lighting | Illuminance Range: (10 – 10000) lx Direct measurement method | PN-83/E-04040.03 | ||
| 4 | Workplace environment - indoor electric lighting | Illuminance uniformity (calculated) | |||
| 5 | Workplace environment - air | Sampling for occupational exposure assessment to: - dust agents - inhalable fraction - respirable fraction - organic substances, including - inhalable fraction - inorganic substances - respirable fraction - metals and their compounds, including - inhalable fraction - respirable fraction Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | ||
| 6 | Workplace environment - air | Exposure index (calculated) | |||
| 7 | Workplace environment - air | Concentration of harmful dust agents – inhalable fraction: - Petroleum asphalt - Apatites and phosphorites - Portland cement - Titanium dioxide - Natural graphite - Synthetic graphite - Kaolin - Amorphous and synthetic silica - Wood dust - Flour dust - Dusts not classified according to toxicity - Organic dusts of animal and plant origin except wood and flour dust - Calcium sulphate (VI) (gypsum) - Carbon black - Coal (hard, brown) - Magnesium calcium carbonate (dolomite) - Silicon carbide, non-fibrous Range: (0,21 – 17,01) mg/m3 Gravimetric method | PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08 | ||
| 8 | Workplace environment - air | Concentration of harmful dust agents – respirable fraction: - Apatites and phosphorites - Portland cement - Natural graphite - Amorphous and synthetic silica - Organic dusts of animal and plant origin except wood and flour dust - Coal (hard, brown) Range: (0,21-14,61) mg/m3 Gravimetric method | PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08 | ||
| 9 | Workplace environment - energy expenditure | Air temperature Range: (5 – 40) °C Air flow rate Range: (10 – 60) dm³/min Direct measurement method | Instrukcja Operacyjna IO-7 Pomiary i szacowanie wydatku energetycznego | ||
| 10 | Workplace environment - energy expenditure | Energy expenditure (calculated) | |||
| 11 | Workplace environment – hand-arm vibration | Frequency-weighted r.m.s. vibration acceleration Range: (0,5 – 120) m/s2 Direct measurement method | PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 12 | Workplace environment – hand-arm vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (a , a , a ) hwx hwy hwz Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (a , a , a ) hwx hwy hwz (calculated) | |||
| 13 | Workplace environment – whole-body vibration | Frequency-weighted effective vibration acceleration Range: (0,04 – 50) m/s² Direct measurement method | PN-EN 14253+A1:2011 | ||
| 14 | Workplace environment – whole-body vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4a , 1.4a , a ) wx wy wz Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4a , 1.4a , a ) wx wy wz (calculated) | |||
| 15 | Workplace environment – moderate microclimate | Air temperature Range: (10 – 30) °C Blackened globe temperature Range: (10 – 35) °C Air humidity Range: (20 – 90) % Air velocity Range: (0,15 – 5,0) m/s Direct measurement method | PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap2:2016-04 | ||
| 16 | Workplace environment – moderate microclimate | PMV index PPD index (calculated) | |||
| 17 | Workplace environment – cold microclimate | Air temperature Range: (-30 – 10) °C Blackened globe temperature Range: (-30 – 10) °C Air humidity Range: (20 – 90) % Air velocity Range: (0,15 – 5,0) m/s Direct measurement method | PN-EN ISO 11079:2008 | ||
| 18 | Workplace environment – cold microclimate | IREQ min index IREQ neutral index t wc index (calculated) | |||
| 19 | Workplace environment – hot microclimate | Air temperature Range: (15 – 40) °C Natural wet bulb temperature Range: (15 – 40) °C Black globe temperature Range: (15 – 40) °C Direct measurement method | PN-EN ISO 7243:2018-01 | ||
| 20 | Workplace environment – hot microclimate | WBGT index WBGT eff index (calculated) | |||
Reference standards (11)
Instrukcja Operacyjna IO-7 Pomiary i szacowanie wydatku energetycznego
PN-83/E-04040.03
PN-EN 14253+A1:2011
PN-EN ISO 11079:2008
PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 p. 10 i strategię 3 p. 11 PN-N-01307:1994
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08