{"lab":{"_id":"69ad52a3de79e566650fb5c6","accr_number":"AB 1131","country":"PL","accr_body":"PCA","address":"Laboratorium Środowiska Pracy, Os. Armii Krajowej 105","categories":["environment","construction"],"city":"","imported_at":"2026-03-08T10:42:43.265Z","methods_count":20,"name":"LABOD Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1131.pdf"],"scope_summary":"","search_text":"labod sp. z o.o. laboratorium środowiska pracy, os. armii krajowej 105 other environment pharma electronics metrology materials construction","status":"active","updated_at":"2026-03-08T14:50:18.486Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:18.486Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%201131,podmiot.html","parse_date":"2026-07-17T16:18:53.044Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, oświetlenie, wydatek energetyczny, drgania, mikroklimat)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, lighting, energy expenditure, vibration, microclimate)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek - środowisko pracy (czynniki szkodliwe – powietrze)","en":"Tests of physical properties and sampling – working environment (harmful factors – air)"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze)","en":"Sampling – working environment (harmful factors – air)"}],"issue":{"no":"20","date":"12.01.2026"},"has_en":true,"category_counts":{"environment":20,"construction":2,"materials":1},"category_scores":{"environment":17.39,"construction":0.17,"materials":0.04},"has_zh":true},"methods":[{"_id":"6a5a55ed9af9f73f38250268","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C Zakres: (55 – 138) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level A-weighted maximum sound level C-weighted peak sound level Range: (55 – 138) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C Zakres: (55 – 138) dB Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 p. 10 i strategię 3 p. 11 PN-N-01307:1994","norm_bases":["PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 p. 10 i strategię 3 p. 11 PN-N-01307:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C Zakres: (55 – 138) dB Metoda pomiarowa bezpośrednia PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 p. 10 i strategię 3 p. 11 PN-N-01307:1994 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Szczytowy poziom dzwieku C Zakres: (55 – 138) dB Metoda pomiarowa bezposrednia PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 p. 10 i strategie 3 p. 11 PN-N-01307:1994","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - noise A-weighted equivalent sound level A-weighted maximum sound level C-weighted peak sound level Range: (55 – 138) dB Direct measurement method PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 p. 10 i strategię 3 p. 11 PN-N-01307:1994","search_zh":"工作场所环境 — 噪声 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 p. 10 i strategię 3 p. 11 PN-N-01307:1994","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5a55ed9af9f73f38250269","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Poziom ekspozycji na hałas odniesiony do: - 8 godzinnego dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","methodology_en":"Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do: - 8 godzinnego dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do: - 8 godzinnego dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do: - 8 godzinnego dobowego wymiaru czasu pracy - przecietnego tygodniowego wymiaru czasu pracy (z obliczen)","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - noise Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated)","methodology_zh":"噪声暴露级，折算至：- 8 小时工作日 - 平均每周工作时间（计算得出）","search_zh":"工作场所环境 — 噪声 噪声暴露级，折算至：- 8 小时工作日 - 平均每周工作时间（计算得出）","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5a55ed9af9f73f3825026a","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment - indoor electric lighting","methodology":"Natężenie oświetlenia Zakres: (10 – 10000) lx Metoda pomiarowa bezpośrednia","methodology_en":"Illuminance Range: (10 – 10000) lx Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie oświetlenia Zakres: (10 – 10000) lx Metoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia Zakres: (10 – 10000) lx Metoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia Zakres: (10 – 10000) lx Metoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - indoor electric lighting Illuminance Range: (10 – 10000) lx Direct measurement method PN-83/E-04040.03","search_zh":"工作场所环境 — 室内电气照明 PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a5a55ed9af9f73f3825026b","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment - indoor electric lighting","methodology":"Równomierność oświetlenia (z obliczeń)","methodology_en":"Illuminance uniformity (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen)","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - indoor electric lighting Illuminance uniformity (calculated)","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值）","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a5a55ed9af9f73f3825026c","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na: - czynniki pyłowe - frakcja wdychalna - frakcja respirabilna - substancje organiczne, w tym - frakcja wdychalna - substancje nieorganiczne - frakcja respirabilna - metale i ich związki, w tym - frakcja wdychalna - frakcja respirabilna Metoda dozymetrii indywidualnej","methodology_en":"Sampling for occupational exposure assessment to: - dust agents - inhalable fraction - respirable fraction - organic substances, including - inhalable fraction - inorganic substances - respirable fraction - metals and their compounds, including - inhalable fraction - respirable fraction Personal dosimetry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na: - czynniki pyłowe - frakcja wdychalna - frakcja respirabilna - substancje organiczne, w tym - frakcja wdychalna - substancje nieorganiczne - frakcja respirabilna - metale i ich związki, w tym - frakcja wdychalna - frakcja respirabilna Metoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na: - czynniki pyłowe - frakcja wdychalna - frakcja respirabilna - substancje organiczne, w tym - frakcja wdychalna - substancje nieorganiczne - frakcja respirabilna - metale i ich związki, w tym - frakcja wdychalna - frakcja respirabilna Metoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na: - czynniki pylowe - frakcja wdychalna - frakcja respirabilna - substancje organiczne, w tym - frakcja wdychalna - substancje nieorganiczne - frakcja respirabilna - metale i ich zwiazki, w tym - frakcja wdychalna - frakcja respirabilna Metoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - air Sampling for occupational exposure assessment to: - dust agents - inhalable fraction - respirable fraction - organic substances, including - inhalable fraction - inorganic substances - respirable fraction - metals and their compounds, including - inhalable fraction - respirable fraction Personal dosimetry method PN-Z-04008-7:2002+Az1:2004","search_zh":"工作场所环境 — 空气 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55ed9af9f73f3825026d","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen)","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - air Exposure index (calculated)","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出）","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55ed9af9f73f3825026e","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna: - Asfalt naftowy - Apatyty i fosforyty - Cement portlandzki - Ditlenek tytanu - Grafit naturalny - Grafit syntetyczny - Kaolin - Krzemionka bezpostaciowa i syntetyczna - Pyły drewna - Pyły mąki - Pyły niesklasyfikowane ze względu na toksyczność - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Siarczan (VI) wapnia (gips) - Sadza techniczna - Węgiel (kamienny, brunatny) - Węglan magnezu wapnia (dolomit) - Węglik krzemu, niewłóknisty Zakres: (0,21 – 17,01) mg/m3 Metoda grawimetryczna","methodology_en":"Concentration of harmful dust agents – inhalable fraction: - Petroleum asphalt - Apatites and phosphorites - Portland cement - Titanium dioxide - Natural graphite - Synthetic graphite - Kaolin - Amorphous and synthetic silica - Wood dust - Flour dust - Dusts not classified according to toxicity - Organic dusts of animal and plant origin except wood and flour dust - Calcium sulphate (VI) (gypsum) - Carbon black - Coal (hard, brown) - Magnesium calcium carbonate (dolomite) - Silicon carbide, non-fibrous Range: (0,21 – 17,01) mg/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna: - Asfalt naftowy - Apatyty i fosforyty - Cement portlandzki - Ditlenek tytanu - Grafit naturalny - Grafit syntetyczny - Kaolin - Krzemionka bezpostaciowa i syntetyczna - Pyły drewna - Pyły mąki - Pyły niesklasyfikowane ze względu na toksyczność - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Siarczan (VI) wapnia (gips) - Sadza techniczna - Węgiel (kamienny, brunatny) - Węglan magnezu wapnia (dolomit) - Węglik krzemu, niewłóknisty Zakres: (0,21 – 17,01) mg/m3 Metoda grawimetryczna","reference":"PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna: - Asfalt naftowy - Apatyty i fosforyty - Cement portlandzki - Ditlenek tytanu - Grafit naturalny - Grafit syntetyczny - Kaolin - Krzemionka bezpostaciowa i syntetyczna - Pyły drewna - Pyły mąki - Pyły niesklasyfikowane ze względu na toksyczność - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Siarczan (VI) wapnia (gips) - Sadza techniczna - Węgiel (kamienny, brunatny) - Węglan magnezu wapnia (dolomit) - Węglik krzemu, niewłóknisty Zakres: (0,21 – 17,01) mg/m3 Metoda grawimetryczna PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna: - Asfalt naftowy - Apatyty i fosforyty - Cement portlandzki - Ditlenek tytanu - Grafit naturalny - Grafit syntetyczny - Kaolin - Krzemionka bezpostaciowa i syntetyczna - Pyly drewna - Pyly maki - Pyly niesklasyfikowane ze wzgledu na toksycznosc - Pyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki - Siarczan (VI) wapnia (gips) - Sadza techniczna - Wegiel (kamienny, brunatny) - Weglan magnezu wapnia (dolomit) - Weglik krzemu, niewloknisty Zakres: (0,21 – 17,01) mg/m3 Metoda grawimetryczna PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - air Concentration of harmful dust agents – inhalable fraction: - Petroleum asphalt - Apatites and phosphorites - Portland cement - Titanium dioxide - Natural graphite - Synthetic graphite - Kaolin - Amorphous and synthetic silica - Wood dust - Flour dust - Dusts not classified according to toxicity - Organic dusts of animal and plant origin except wood and flour dust - Calcium sulphate (VI) (gypsum) - Carbon black - Coal (hard, brown) - Magnesium calcium carbonate (dolomite) - Silicon carbide, non-fibrous Range: (0,21 – 17,01) mg/m3 Gravimetric method PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08","search_zh":"工作场所环境 — 空气 PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55ed9af9f73f3825026f","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna: - Apatyty i fosforyty - Cement portlandzki - Grafit naturalny - Krzemionka bezpostaciowa i syntetyczna - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Węgiel (kamienny, brunatny) Zakres: (0,21-14,61) mg/m3 Metoda grawimetryczna","methodology_en":"Concentration of harmful dust agents – respirable fraction: - Apatites and phosphorites - Portland cement - Natural graphite - Amorphous and synthetic silica - Organic dusts of animal and plant origin except wood and flour dust - Coal (hard, brown) Range: (0,21-14,61) mg/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna: - Apatyty i fosforyty - Cement portlandzki - Grafit naturalny - Krzemionka bezpostaciowa i syntetyczna - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Węgiel (kamienny, brunatny) Zakres: (0,21-14,61) mg/m3 Metoda grawimetryczna","reference":"PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna: - Apatyty i fosforyty - Cement portlandzki - Grafit naturalny - Krzemionka bezpostaciowa i syntetyczna - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Węgiel (kamienny, brunatny) Zakres: (0,21-14,61) mg/m3 Metoda grawimetryczna PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna: - Apatyty i fosforyty - Cement portlandzki - Grafit naturalny - Krzemionka bezpostaciowa i syntetyczna - Pyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki - Wegiel (kamienny, brunatny) Zakres: (0,21-14,61) mg/m3 Metoda grawimetryczna PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - air Concentration of harmful dust agents – respirable fraction: - Apatites and phosphorites - Portland cement - Natural graphite - Amorphous and synthetic silica - Organic dusts of animal and plant origin except wood and flour dust - Coal (hard, brown) Range: (0,21-14,61) mg/m3 Gravimetric method PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08","search_zh":"工作场所环境 — 空气 PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5a55ed9af9f73f38250270","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy - wydatek energetyczny","test_object_en":"Workplace environment - energy expenditure","methodology":"Temperatura powietrza Zakres: (5 – 40) °C Przepływ powietrza Zakres: (10 – 60) dm³/min Metoda pomiarowa bezpośrednia","methodology_en":"Air temperature Range: (5 – 40) °C Air flow rate Range: (10 – 60) dm³/min Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura powietrza Zakres: (5 – 40) °C Przepływ powietrza Zakres: (10 – 60) dm³/min Metoda pomiarowa bezpośrednia","reference":"Instrukcja Operacyjna IO-7 Pomiary i szacowanie wydatku energetycznego","norm_bases":["Instrukcja Operacyjna IO-7 Pomiary i szacowanie wydatku energetycznego"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - wydatek energetyczny Temperatura powietrza Zakres: (5 – 40) °C Przepływ powietrza Zakres: (10 – 60) dm³/min Metoda pomiarowa bezpośrednia Instrukcja Operacyjna IO-7 Pomiary i szacowanie wydatku energetycznego Srodowisko pracy - wydatek energetyczny Temperatura powietrza Zakres: (5 – 40) °C Przeplyw powietrza Zakres: (10 – 60) dm³/min Metoda pomiarowa bezposrednia Instrukcja Operacyjna IO-7 Pomiary i szacowanie wydatku energetycznego","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - energy expenditure Air temperature Range: (5 – 40) °C Air flow rate Range: (10 – 60) dm³/min Direct measurement method Instrukcja Operacyjna IO-7 Pomiary i szacowanie wydatku energetycznego","search_zh":"工作场所环境 — 能量消耗 Instrukcja Operacyjna IO-7 Pomiary i szacowanie wydatku energetycznego","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a5a55ed9af9f73f38250271","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy - wydatek energetyczny","test_object_en":"Workplace environment - energy expenditure","methodology":"Wydatek energetyczny (z obliczeń)","methodology_en":"Energy expenditure (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wydatek energetyczny (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - wydatek energetyczny Wydatek energetyczny (z obliczeń) Srodowisko pracy - wydatek energetyczny Wydatek energetyczny (z obliczen)","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment - energy expenditure Energy expenditure (calculated)","methodology_zh":"能量消耗（计算值）","search_zh":"工作场所环境 — 能量消耗 能量消耗（计算值）","test_object_zh":"工作场所环境 — 能量消耗"},{"_id":"6a5a55ed9af9f73f38250272","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","test_object_en":"Workplace environment – hand-arm vibration","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,5 – 120) m/s2 Metoda pomiarowa bezpośrednia","methodology_en":"Frequency-weighted r.m.s. vibration acceleration Range: (0,5 – 120) m/s2 Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,5 – 120) m/s2 Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,5 – 120) m/s2 Metoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan Zakres: (0,5 – 120) m/s2 Metoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Range: (0,5 – 120) m/s2 Direct measurement method PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11","search_zh":"工作场所环境 — 手传振动 PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a5a55ed9af9f73f38250273","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne","test_object_en":"Workplace environment – hand-arm vibration","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a , a , a ) hwx hwy hwz Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a , a , a ) hwx hwy hwz (z obliczeń)","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (a , a , a ) hwx hwy hwz Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (a , a , a ) hwx hwy hwz (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a , a , a ) hwx hwy hwz Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a , a , a ) hwx hwy hwz (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a , a , a ) hwx hwy hwz Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (a , a , a ) hwx hwy hwz (z obliczeń) Srodowisko pracy – drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (a , a , a ) hwx hwy hwz Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (a , a , a ) hwx hwy hwz (z obliczen)","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (a , a , a ) hwx hwy hwz Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (a , a , a ) hwx hwy hwz (calculated)","search_zh":"工作场所环境 — 手传振动 日暴露量，以三个方向分量（a hwx、a hwy、a hwz）所测定的频率计权有效振动加速度矢量和的8小时能量等效值表示；持续30分钟及以下的暴露量，以三个方向分量（a hwx、a hwy、a hwz）所测定的频率计权有效振动加速度矢量和表示（由计算得出）","test_object_zh":"工作场所环境 — 手传振动","methodology_zh":"日暴露量，以三个方向分量（a hwx、a hwy、a hwz）所测定的频率计权有效振动加速度矢量和的8小时能量等效值表示；持续30分钟及以下的暴露量，以三个方向分量（a hwx、a hwy、a hwz）所测定的频率计权有效振动加速度矢量和表示（由计算得出）"},{"_id":"6a5a55ed9af9f73f38250274","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment – whole-body vibration","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,04 – 50) m/s² Metoda pomiarowa bezpośrednia","methodology_en":"Frequency-weighted effective vibration acceleration Range: (0,04 – 50) m/s² Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,04 – 50) m/s² Metoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań Zakres: (0,04 – 50) m/s² Metoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan Zakres: (0,04 – 50) m/s² Metoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – whole-body vibration Frequency-weighted effective vibration acceleration Range: (0,04 – 50) m/s² Direct measurement method PN-EN 14253+A1:2011","search_zh":"工作场所环境 — 全身振动 PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a5a55ed9af9f73f38250275","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka","test_object_en":"Workplace environment – whole-body vibration","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4a , 1.4a , a ) wx wy wz Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4a , 1.4a , a ) wx wy wz (z obliczeń)","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4a , 1.4a , a ) wx wy wz Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4a , 1.4a , a ) wx wy wz (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4a , 1.4a , a ) wx wy wz Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4a , 1.4a , a ) wx wy wz (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4a , 1.4a , a ) wx wy wz Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4a , 1.4a , a ) wx wy wz (z obliczeń) Srodowisko pracy – drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4a , 1.4a , a ) wx wy wz Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4a , 1.4a , a ) wx wy wz (z obliczen)","categories":["environment"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4a , 1.4a , a ) wx wy wz Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4a , 1.4a , a ) wx wy wz (calculated)","search_zh":"工作场所环境 — 全身振动 日暴露量，以考虑相应系数后三个方向分量（1.4a wx、1.4a wy、a wz）所测定的振动加速度中占主导的频率计权有效振动加速度的8小时能量等效值表示；持续30分钟及以下的暴露量，以考虑相应系数后三个方向分量（1.4a wx、1.4a wy、a wz）所测定的振动加速度中占主导的频率计权有效振动加速度表示（由计算得出）","test_object_zh":"工作场所环境 — 全身振动","methodology_zh":"日暴露量，以考虑相应系数后三个方向分量（1.4a wx、1.4a wy、a wz）所测定的振动加速度中占主导的频率计权有效振动加速度的8小时能量等效值表示；持续30分钟及以下的暴露量，以考虑相应系数后三个方向分量（1.4a wx、1.4a wy、a wz）所测定的振动加速度中占主导的频率计权有效振动加速度表示（由计算得出）"},{"_id":"6a5a55ed9af9f73f38250276","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","test_object_en":"Workplace environment – moderate microclimate","methodology":"Temperatura powietrza Zakres: (10 – 30) °C Temperatura poczernionej kuli Zakres: (10 – 35) °C Wilgotność powietrza Zakres: (20 – 90) % Prędkość powietrza Zakres: (0,15 – 5,0) m/s Metoda pomiarowa bezpośrednia","methodology_en":"Air temperature Range: (10 – 30) °C Blackened globe temperature Range: (10 – 35) °C Air humidity Range: (20 – 90) % Air velocity Range: (0,15 – 5,0) m/s Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura powietrza Zakres: (10 – 30) °C Temperatura poczernionej kuli Zakres: (10 – 35) °C Wilgotność powietrza Zakres: (20 – 90) % Prędkość powietrza Zakres: (0,15 – 5,0) m/s Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat umiarkowany Temperatura powietrza Zakres: (10 – 30) °C Temperatura poczernionej kuli Zakres: (10 – 35) °C Wilgotność powietrza Zakres: (20 – 90) % Prędkość powietrza Zakres: (0,15 – 5,0) m/s Metoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy – mikroklimat umiarkowany Temperatura powietrza Zakres: (10 – 30) °C Temperatura poczernionej kuli Zakres: (10 – 35) °C Wilgotnosc powietrza Zakres: (20 – 90) % Predkosc powietrza Zakres: (0,15 – 5,0) m/s Metoda pomiarowa bezposrednia PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – moderate microclimate Air temperature Range: (10 – 30) °C Blackened globe temperature Range: (10 – 35) °C Air humidity Range: (20 – 90) % Air velocity Range: (0,15 – 5,0) m/s Direct measurement method PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap2:2016-04","search_zh":"工作场所环境 — 中等微气候 PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a5a55ed9af9f73f38250277","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","test_object_en":"Workplace environment – moderate microclimate","methodology":"Wskaźnik PMV Wskaźnik PPD (z obliczeń)","methodology_en":"PMV index PPD index (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik PMV Wskaźnik PPD (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat umiarkowany Wskaźnik PMV Wskaźnik PPD (z obliczeń) Srodowisko pracy – mikroklimat umiarkowany Wskaznik PMV Wskaznik PPD (z obliczen)","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – moderate microclimate PMV index PPD index (calculated)","search_zh":"工作场所环境 — 中等微气候 PMV 指数 PPD 指数（计算值）","test_object_zh":"工作场所环境 — 中等微气候","methodology_zh":"PMV 指数 PPD 指数（计算值）"},{"_id":"6a5a55ed9af9f73f38250278","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","test_object_en":"Workplace environment – cold microclimate","methodology":"Temperatura powietrza Zakres: (-30 – 10) °C Temperatura poczernionej kuli Zakres: (-30 – 10) °C Wilgotność powietrza Zakres: (20 – 90) % Prędkość powietrza Zakres: (0,15 – 5,0) m/s Metoda pomiarowa bezpośrednia","methodology_en":"Air temperature Range: (-30 – 10) °C Blackened globe temperature Range: (-30 – 10) °C Air humidity Range: (20 – 90) % Air velocity Range: (0,15 – 5,0) m/s Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura powietrza Zakres: (-30 – 10) °C Temperatura poczernionej kuli Zakres: (-30 – 10) °C Wilgotność powietrza Zakres: (20 – 90) % Prędkość powietrza Zakres: (0,15 – 5,0) m/s Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat zimny Temperatura powietrza Zakres: (-30 – 10) °C Temperatura poczernionej kuli Zakres: (-30 – 10) °C Wilgotność powietrza Zakres: (20 – 90) % Prędkość powietrza Zakres: (0,15 – 5,0) m/s Metoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy – mikroklimat zimny Temperatura powietrza Zakres: (-30 – 10) °C Temperatura poczernionej kuli Zakres: (-30 – 10) °C Wilgotnosc powietrza Zakres: (20 – 90) % Predkosc powietrza Zakres: (0,15 – 5,0) m/s Metoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – cold microclimate Air temperature Range: (-30 – 10) °C Blackened globe temperature Range: (-30 – 10) °C Air humidity Range: (20 – 90) % Air velocity Range: (0,15 – 5,0) m/s Direct measurement method PN-EN ISO 11079:2008","search_zh":"工作场所环境 — 低温微气候 PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a5a55ed9af9f73f38250279","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","test_object_en":"Workplace environment – cold microclimate","methodology":"Wskaźnik IREQ min Wskaźnik IREQ neutral Wskaźnik t wc (z obliczeń)","methodology_en":"IREQ min index IREQ neutral index t wc index (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik IREQ min Wskaźnik IREQ neutral Wskaźnik t wc (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat zimny Wskaźnik IREQ min Wskaźnik IREQ neutral Wskaźnik t wc (z obliczeń) Srodowisko pracy – mikroklimat zimny Wskaznik IREQ min Wskaznik IREQ neutral Wskaznik t wc (z obliczen)","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – cold microclimate IREQ min index IREQ neutral index t wc index (calculated)","search_zh":"工作场所环境 — 低温微气候 IREQ min 指数 IREQ neutral 指数 t wc 指数（由计算得出）","test_object_zh":"工作场所环境 — 低温微气候","methodology_zh":"IREQ min 指数 IREQ neutral 指数 t wc 指数（由计算得出）"},{"_id":"6a5a55ed9af9f73f3825027a","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","test_object_en":"Workplace environment – hot microclimate","methodology":"Temperatura powietrza Zakres: (15 – 40) °C Temperatura wilgotna naturalna Zakres: (15 – 40) °C Temperatura poczernionej kuli Zakres: (15 – 40) °C Metoda pomiarowa bezpośrednia","methodology_en":"Air temperature Range: (15 – 40) °C Natural wet bulb temperature Range: (15 – 40) °C Black globe temperature Range: (15 – 40) °C Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Temperatura powietrza Zakres: (15 – 40) °C Temperatura wilgotna naturalna Zakres: (15 – 40) °C Temperatura poczernionej kuli Zakres: (15 – 40) °C Metoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat gorący Temperatura powietrza Zakres: (15 – 40) °C Temperatura wilgotna naturalna Zakres: (15 – 40) °C Temperatura poczernionej kuli Zakres: (15 – 40) °C Metoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Temperatura powietrza Zakres: (15 – 40) °C Temperatura wilgotna naturalna Zakres: (15 – 40) °C Temperatura poczernionej kuli Zakres: (15 – 40) °C Metoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – hot microclimate Air temperature Range: (15 – 40) °C Natural wet bulb temperature Range: (15 – 40) °C Black globe temperature Range: (15 – 40) °C Direct measurement method PN-EN ISO 7243:2018-01","search_zh":"工作场所环境 — 高温微气候 PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a5a55ed9af9f73f3825027b","lab_id":"69ad52a3de79e566650fb5c6","country":"PL","accr_number":"AB 1131","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","test_object_en":"Workplace environment – hot microclimate","methodology":"Wskaźnik WBGT Wskaźnik WBGT eff (z obliczeń)","methodology_en":"WBGT index WBGT eff index (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik WBGT Wskaźnik WBGT eff (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – mikroklimat gorący Wskaźnik WBGT Wskaźnik WBGT eff (z obliczeń) Srodowisko pracy – mikroklimat goracy Wskaznik WBGT Wskaznik WBGT eff (z obliczen)","categories":["environment"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – hot microclimate WBGT index WBGT eff index (calculated)","search_zh":"工作场所环境 — 高温微气候 WBGT 指数；WBGT eff 指数（由计算得出）","test_object_zh":"工作场所环境 — 高温微气候","methodology_zh":"WBGT 指数；WBGT eff 指数（由计算得出）"}],"has_pdf":true}