🇵🇱 SALUBRIS SP. Z O.O. PL
Water & wastewaterEnvironmentFood & beveragesConstruction
SALUBRIS SP. Z O.O. is a laboratory accredited by PCA under number AB 1127 (Tulce, Poland). Its accreditation scope covers 53 test methods in the following areas: Water & wastewater, Environment, Food & beverages, Construction. Test objects include: Water Wastewater, Water, WasteDAB-11: - Sludges and mineral waste (I) - Construction waste (…, Water intended for human consumption.
At a glance
- Accreditation number: PCA AB 1127
- Methods in scope: 53
- Types of test objects: 17
- City: Tulce, Poland
- Accreditation number
- AB 1127
- Accreditation body
- PCA
- Address
- LABORATORIUM SALUBRIS, ul. Poznańska 2, 63-004 Tulce
- City
- Tulce, Poland
What this laboratory tests (17)
- Water Wastewater — 18 methods
- Water — 7 methods
- WasteDAB-11: - Sludges and mineral waste (I) - Construction waste (III) - Plant, animal and food-processing waste (IV) - Waste from waste treatment (excluding hazardous waste) (VI) - Sewage sludge (IX) - Slags, ashes and furnace dusts (XI) - Waste from the processing of crude oil, natural gas and coal (XXI) - Wood (XXVI) - Leather and textiles (XXVII) - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII) — 5 methods
- Water intended for human consumption — 4 methods
- Water Swimming pool water — 4 methods
- Landfill gases — 2 methods
- Swimming pool water — 2 methods
- WasteDAB-11: - Plant and animal wastes and wastes from food processing (IV) - Wastes from waste treatment (excluding hazardous) (VI) - Sewage sludges (IX) - Other municipal wastes and wastes derived from municipal wastes, including mixed wastes, and other wastes from wastewater and water treatment (XXVIII) — 2 methods
- Groundwater — 1 method
- Sewage sludge — 1 method
- Soil — 1 method
- Solid fuels: solid biomass – solid biofuel — 1 method
- Surface water — 1 method
- WasteDAB-11: - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII) — 1 method
- Wastewater — 1 method
- and 2 more
Accreditation scope — test methods (53)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing Temperature of the collected water sample Range: (5 – 50) °C | PN-ISO 5667-5:2017-10 PN-77/C-04584 | ||
| 2 | Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 3 | Groundwater | Sampling for chemical and physical testing Temperature of the collected water sample Range: (5 – 50) °C | PN-ISO 5667-11:2017-10 z wył. p. 5.2 | PN-77/C-04584 | ||
| 4 | Surface water | Sampling for chemical and physical testing Temperature of the collected water sample Range: (5 – 50) °C | PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 PN-77/C-04584 | ||
| 5 | Wastewater Rainwater | Sampling for chemical and physical testing Manual and automatic method Temperature of the wastewater sample taken Range: (5 – 50) °C | PN-ISO 5667-10:2021-11 PN-77/C-04584 | ||
| 6 | Water intended for human consumption | Presence of foreign odour and taste Qualitative method | PN-EN 1622:2006 Załącznik C | ||
| 7 | Water intended for human consumption | Threshold odour number TON Range: (1 – 2) Threshold flavour number TFN Range: (1 – 2) Simplified method, paired, non-forced choice | PN-EN 1622:2006 | ||
| 8 | Water Swimming pool water | Most probable number of coliform bacteria MPN method, Colilert 18 Test | PN-EN ISO 9308-2:2014-06 | ||
| 9 | Water Swimming pool water | Most probable number of Escherichia coli MPN method, Colilert 18 Test | |||
| 10 | Water Swimming pool water | Most probable number of Pseudomonas aeruginosa MPN method, Pseudalert Test | PN-EN ISO 16266-2:2022-04 | ||
| 11 | Water | Most probable number of enterococci MPN method, Enterolert E Test | Instrukcja testu IDEXX Enterolert E 2019 | ||
| 12 | Water | Most probable number of enterococci MPN method, Enterolert DW Test | Instrukcja testu IDEXX Enterolert DW 2019 | ||
| 13 | Water | Total count of microorganisms at 22 °C Plate method, pour plate | PN-EN ISO 6222:2004 | ||
| 14 | Water | Total count of microorganisms at 36 °C Plate method, pour plate | |||
| 15 | Water Swimming pool water | Turbidity Range: (0,10 – 50) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 16 | Water | Colour Range: (2,5 – 250) mg/l Pt Visual method | PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D | ||
| 17 | Water | Dissolved oxygen concentration Range: (1,0 – 15) mg/l O2 Optical method | ISO 17289:2014 | ||
| 18 | Water | Element concentrations Range: Manganese (0,025 – 10,0) mg/l Iron (0,050 – 20,0) mg/l Flame atomic absorption spectrometry method (FAAS) | PN-ISO 8288:2002 metoda A | ||
| 19 | Water Wastewater | pH Range: 3,0 – 12,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 20 | Water Wastewater | Electrical conductivity Range: (5,0 – 50000) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 21 | Water Wastewater | Ion concentration Range: Ammonium ion (0,10 – 500) mg/l Lithium (0,05 – 50) mg/l Magnesium (0,25 – 500) mg/l Potassium (0,50 – 500) mg/l Sodium (2,0 – 2000) mg/l Calcium (2,0 – 2000) mg/l Strontium (0,05 – 50) mg/l Barium (0,05 – 50) mg/l Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 14911:2002 | ||
| 22 | Water Wastewater | Ion concentration: Range: Nitrates (0,10 – 500) mg/l Nitrites (0,050 – 200) mg/l Bromides (0,20 – 100) mg/l Chlorides (0,10 – 3000) mg/l Fluorides (0,10 – 100) mg/l Phosphates (0,05 – 500) mg/l Sulphates (0,20 – 2000) mg/l Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | ||
| 23 | Swimming pool water | Ion concentration: Range: Nitrates (0,10 – 500) mg/l Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | ||
| 24 | Swimming pool water | Iron concentration Range: (0,050 – 20,0) mg/l Flame atomic absorption spectrometry method (FAAS) | PN-ISO 8288:2002 metoda A | ||
| 25 | Water Swimming pool water Wastewater | Total organic carbon concentration Range: (0,5 – 5000) mg/l High-temperature combustion with infrared range detection (IR) | PN-EN 1484:1999 | ||
| 26 | Water Wastewater | Chromium VI concentration Range: (0,001 – 200) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 PB-29i wydanie 1 z dnia 01.10.2020 r. | ||
| 27 | Water Wastewater | Mercury concentration Range: (0,0001 – 0,10) mg/l Cold vapour atomic absorption spectrometry method (CVAAS) | PN-EN ISO 12846:2012-06 z wył. p. 7 | ||
| 28 | Water Wastewater | Element concentrations Range: Antimony (0,0030 – 200) mg/l Arsenic (0,0050 – 200) mg/l Barium (0,00050 – 100) mg/l Boron (0,010 – 200) mg/l Beryllium (0,00050 – 200) mg/l Chromium (0,0010 – 200) mg/l Tin (0,0050 – 200) mg/l Zinc (0,0010 – 200) mg/l Aluminium (0,010 – 200) mg/l Cadmium (0,00050 – 200) mg/l Cobalt (0,0010 – 200) mg/l Manganese (0,0010 – 200) mg/l Copper (0,0030 – 200) mg/l Molybdenum (0,0050 – 200) mg/l Nickel (0,0030 – 200) mg/l Lead (0,0050 – 200) mg/l Mercury (0,0050 – 100) mg/l Selenium (0,0050 – 200) mg/l Silver (0,0010 – 200) mg/l Strontium (0,00050 – 100) mg/l Thallium (0,0050 – 200) mg/l Titanium (0,0010 – 200) mg/l Vanadium (0,0010 – 200) mg/l Iron (0,0030 – 200) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | ||
| 29 | Water Wastewater | Concentration of petroleum hydrocarbons Range: (0,05 – 100) mg/l Infrared spectrometry method (IR) | PB-25b wydanie 2 z dnia 13.09.2023 r. | ||
| 30 | Water Wastewater | Biochemical oxygen demand - BOD5 Range: (1,0 – 3000) mg/l O2 Optical method | PN-EN ISO 5815-1:2019-12 | ||
| 31 | Water Wastewater | Chemical oxygen demand - CODCr Range: (3,0 – 22000) mg/l O2 Spectrophotometric method | PN-ISO 15705:2005 | ||
| 32 | Water Wastewater | Total phosphorus concentration Range: (0,05 – 100) mg/l Spectrophotometric method | PB-19d wydanie 2 z dnia 05.04.2022 r. na podstawie testu Nanocolor nr 0-80, 0-81, 0-76, 0-55 | ||
| 33 | Water Wastewater | Total nitrogen concentration Range: (0,5 – 500) mg/l Spectrophotometric method | PB-19e wydanie 2 z dnia 13.09.2023 r. na podstawie testu Nanocolor nr 0-83, 0-88, 0-92 | ||
| 34 | Water Wastewater | Organic nitrogen and Kjeldahl nitrogen concentration (calculated) | PB-19k wydanie 1 z dnia 22.09.2008 r. | ||
| 35 | Water Wastewater | Total alkalinity (hydrogen carbonates) Range: (16,0 – 5000) mg/l Titrimetric method | PN-ISO 9963-1:2001+Ap1:2004 | ||
| 36 | Water Wastewater | Total calcium and magnesium content (total hardness) (calculated) | PB-09 wydanie 2 z dnia 05.08.2009 r. | ||
| 37 | Water Wastewater | Total suspended solids (TSS) Range: (2,0 – 1000) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 38 | Water Wastewater | Anionic detergent concentration (anionic surfactants) Range: (0,20 − 50) mg/l Spectrophotometric method | PB-26a wydanie 2 z dnia 14.06.2019 r. na podstawie testu Nanocolor nr 0-32 | ||
| 39 | Water Wastewater | Non-ionic detergent concentration (non-ionic surfactants) Range: (0,30 − 50) mg/l Spectrophotometric method | PB-26l wydanie 2 z dnia 14.06.2019 r. na podstawie testu Nanocolor nr 0-47 | ||
| 40 | Wastewater | Element concentrations Range: Chromium (0,050 – 10,0) mg/l Zinc (0,025 – 10,0) mg/l Cadmium (0,025 – 5,0) mg/l Lead (0,100 – 20,0) mg/l Manganese (0,025 – 10,0) mg/l Copper (0,050 – 20,0) mg/l Nickel (0,050 – 10,0) mg/l Iron (0,050 – 20,0) mg/l Flame atomic absorption spectrometry method (FAAS) | PN-ISO 8288:2002 metoda A | ||
| 41 | Soil | Sampling for chemical and physical testing | PN-EN ISO 10381-4:2007 PN-EN ISO 10381-5:2009 | ||
| 42 | Sewage sludge | Sampling for chemical and physical testing | PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3 | ||
| 43 | Landfill gases | Concentration of methane, carbon dioxide, oxygen Range: CH4 (0,5 – 65,0) % CO2 (0,5 – 40,0) % Infrared spectrometry method (IR) Oxygen concentration Range: (0,5 – 21,0) % Electrochemical method Flow velocity Range: (0,15 – 10,0) m/s Thermoanemometric method | PB-27b wydanie 9 z dnia 11.09.2023 r. | ||
| 44 | Landfill gases | Emission of methane, carbon dioxide (calculated) | |||
| 45 | WasteDAB-11: - Sludges and mineral waste (I) - Construction waste (III) - Plant, animal and food-processing waste (IV) - Waste from waste treatment (excluding hazardous waste) (VI) - Sewage sludge (IX) - Slags, ashes and furnace dusts (XI) - Waste from the processing of crude oil, natural gas and coal (XXI) - Wood (XXVI) - Leather and textiles (XXVII) - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII) | Ion content: Range: Chlorides (1,0 – 30000) mg/kg Fluorides (1,0 – 100) mg/kg Sulphates (2,0 – 20000) mg/kg Ion chromatography method with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 PN-EN 12457-2:2006 | ||
| 46 | WasteDAB-11: - Sludges and mineral waste (I) - Construction waste (III) - Plant, animal and food-processing waste (IV) - Waste from waste treatment (excluding hazardous waste) (VI) - Sewage sludge (IX) - Slags, ashes and furnace dusts (XI) - Waste from the processing of crude oil, natural gas and coal (XXI) - Wood (XXVI) - Leather and textiles (XXVII) - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII) | Ion content Range: Barium (0,5 – 50) mg/kg Ion chromatography method with conductometric detection (IC-CD) | PN-EN ISO 14911:2002 PN-EN 12457-2:2006 | ||
| 47 | WasteDAB-11: - Sludges and mineral waste (I) - Construction waste (III) - Plant, animal and food-processing waste (IV) - Waste from waste treatment (excluding hazardous waste) (VI) - Sewage sludge (IX) - Slags, ashes and furnace dusts (XI) - Waste from the processing of crude oil, natural gas and coal (XXI) - Wood (XXVI) - Leather and textiles (XXVII) - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII) | Content of elements Range: Antimony (0,05 – 2000) mg/kg Arsenic (0,05 – 2000) mg/kg Barium (0,005 – 1000) mg/kg Chromium (0,01 – 2000) mg/kg Zinc (0,01 – 2000) mg/kg Cadmium (0,005 – 2000) mg/kg Copper (0,03 – 2000) mg/kg Molybdenum (0,05 – 2000) mg/kg Nickel (0,03 – 2000) mg/kg Lead (0,05– 2000) mg/kg Selenium (0,05 – 2000) mg/kg Mercury (0,05 – 1000) mg/kg Inductively coupled plasma atomic emission spectrometry (ICP-OES) method | PN-EN ISO 11885:2009 PN-EN 12457-2:2006 | ||
| 48 | WasteDAB-11: - Sludges and mineral waste (I) - Construction waste (III) - Plant, animal and food-processing waste (IV) - Waste from waste treatment (excluding hazardous waste) (VI) - Sewage sludge (IX) - Slags, ashes and furnace dusts (XI) - Waste from the processing of crude oil, natural gas and coal (XXI) - Wood (XXVI) - Leather and textiles (XXVII) - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII) | Mercury content Range: (0,001 – 1) mg/kg Cold vapour atomic absorption spectrometry (CVAAS) method | PN-EN 12457-2:2006 PN-EN ISO 12846:2012-06 z wył. p. 7 | ||
| 49 | WasteDAB-11: - Sludges and mineral waste (I) - Construction waste (III) - Plant, animal and food-processing waste (IV) - Waste from waste treatment (excluding hazardous waste) (VI) - Sewage sludge (IX) - Slags, ashes and furnace dusts (XI) - Waste from the processing of crude oil, natural gas and coal (XXI) - Wood (XXVI) - Leather and textiles (XXVII) - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII) | Content of dissolved organic carbon (DOC) Range: (5,0 – 50000) mg/kg High-temperature combustion method with infrared (IR) detection | PN-EN 1484:1999 PN-EN 12457-2:2006 | ||
| 50 | WasteDAB-11: - Plant and animal wastes and wastes from food processing (IV) - Wastes from waste treatment (excluding hazardous) (VI) - Sewage sludges (IX) - Other municipal wastes and wastes derived from municipal wastes, including mixed wastes, and other wastes from wastewater and water treatment (XXVIII) | Gross calorific value Range: (3,000 – 38,000) MJ/kg Calorimetric method | PN-EN ISO 21654:2021-12 | ||
| 51 | WasteDAB-11: - Plant and animal wastes and wastes from food processing (IV) - Wastes from waste treatment (excluding hazardous) (VI) - Sewage sludges (IX) - Other municipal wastes and wastes derived from municipal wastes, including mixed wastes, and other wastes from wastewater and water treatment (XXVIII) | Moisture content in the analytical sample Range: (1,0 – 20,0) % Gravimetric method | PN-EN ISO 21660-3:2021-08 | ||
| 52 | WasteDAB-11: - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII) | Sampling for chemical and physical testing | PN-EN ISO 21645:2021-09 z wył. Załącznika F i H | ||
| 53 | Solid fuels: solid biomass – solid biofuel | Gross calorific value Range: (5,500 – 22,800) MJ/kg Calorimetric method Net calorific value (calculated) | PN-EN ISO 18125:2017-07 | ||
Reference standards (48)
ISO 17289:2014
Instrukcja testu IDEXX Enterolert DW 2019
Instrukcja testu IDEXX Enterolert E 2019
PB-09 wydanie 2 z dnia 05.08.2009 r.
PB-19d wydanie 2 z dnia 05.04.2022 r. na podstawie testu Nanocolor nr 0-80, 0-81, 0-76, 0-55
PB-19e wydanie 2 z dnia 13.09.2023 r. na podstawie testu Nanocolor nr 0-83, 0-88, 0-92
PB-19k wydanie 1 z dnia 22.09.2008 r.
PB-25b wydanie 2 z dnia 13.09.2023 r.
PB-26a wydanie 2 z dnia 14.06.2019 r. na podstawie testu Nanocolor nr 0-32
PB-26l wydanie 2 z dnia 14.06.2019 r. na podstawie testu Nanocolor nr 0-47
PB-27b wydanie 9 z dnia 11.09.2023 r.
PN-77/C-04584
PN-EN 12457-2:2006 PN-EN ISO 12846:2012-06 z wył. p. 7
PN-EN 1484:1999
PN-EN 1484:1999 PN-EN 12457-2:2006
PN-EN 1622:2006
PN-EN 1622:2006 Załącznik C
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10304-1:2009+AC:2012 PN-EN 12457-2:2006
PN-EN ISO 10381-4:2007 PN-EN ISO 10381-5:2009
PN-EN ISO 10523:2012
PN-EN ISO 11885:2009
PN-EN ISO 11885:2009 PB-29i wydanie 1 z dnia 01.10.2020 r.
PN-EN ISO 11885:2009 PN-EN 12457-2:2006
PN-EN ISO 12846:2012-06 z wył. p. 7
PN-EN ISO 14911:2002
PN-EN ISO 14911:2002 PN-EN 12457-2:2006
PN-EN ISO 16266-2:2022-04
PN-EN ISO 18125:2017-07
PN-EN ISO 19458:2007
PN-EN ISO 21645:2021-09 z wył. Załącznika F i H
PN-EN ISO 21654:2021-12
PN-EN ISO 21660-3:2021-08
PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-11:2017-10 z wył. p. 5.2
PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 PN-77/C-04584
PN-ISO 5667-5:2017-10 PN-77/C-04584
PN-ISO 8288:2002 metoda A
PN-ISO 9963-1:2001+Ap1:2004