{"lab":{"_id":"69ad52a3de79e566650fb5c2","accr_number":"AB 1127","country":"PL","accr_body":"PCA","address":"LABORATORIUM SALUBRIS, ul. Poznańska 2, 63-004 Tulce","categories":["water","environment","food","construction"],"city":"Tulce","imported_at":"2026-03-08T10:42:43.265Z","methods_count":53,"name":"SALUBRIS SP. Z O.O.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1127.pdf"],"scope_summary":"","search_text":"salubris sp. z o.o. laboratorium salubris, ul. poznańska 2, 63-004 tulce water microbiology other pharma electronics materials environment construction food petro","status":"active","updated_at":"2026-03-08T14:50:18.343Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:18.343Z","email_confidence":"high","email_mx":true,"email_source":"https://salubris.pl/","parse_date":"2026-07-17T16:18:52.910Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, odpadów","en":"Chemical tests and sampling of water, drinking water, sewage, waiste"},{"codes":"C/36","pl":"Badania chemiczne gazów składowiskowych,","en":"Chemical tests of landfill gases,"},{"codes":"C/10","pl":"Badania chemiczne paliw stałych","en":"Chemical tests of solid fuels"},{"codes":"G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) - gazy składowiskowe","en":"Tests concerning environmental engineering (environmental and climatic) - landfill gases"},{"codes":"N/28/P; N/29/P; N/30/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, odpadów","en":"Tests of physical properties and sampling of water, drinking water, sewage, waste"},{"codes":"Q/29","pl":"Badania sensoryczne wody do spożycia przez ludzi","en":"Sensory tests of drinking water"},{"codes":"K/28; K/29/P","pl":"Badania mikrobiologiczne wody, wody do spożycia i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests of water, drinking water and sampling of drinking water"},{"codes":"P/31, P/32","pl":"Pobieranie próbek gleby, osadów","en":"Sampling of soil, sediments"}],"issue":{"no":"23","date":"05.02.2026"},"map_coord":[52.344577,17.067954],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":49,"environment":10,"food":7,"construction":5,"materials":3,"microbiology":3,"other":1,"petro":1},"category_scores":{"water":30.39,"environment":1.27,"food":0.62,"construction":0.32,"materials":0.11,"microbiology":0.11,"other":0.01,"petro":0.01},"has_zh":true},"methods":[{"_id":"6a5a55ec9af9f73f38250208","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5 – 50) °C","methodology_en":"Sampling for chemical and physical testing Temperature of the collected water sample Range: (5 – 50) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5 – 50) °C","reference":"PN-ISO 5667-5:2017-10 PN-77/C-04584","norm_bases":["PN-ISO 5667-5:2017-10 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5 – 50) °C PN-ISO 5667-5:2017-10 PN-77/C-04584 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody Zakres: (5 – 50) °C PN-ISO 5667-5:2017-10 PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature of the collected water sample Range: (5 – 50) °C PN-ISO 5667-5:2017-10 PN-77/C-04584","search_zh":"生活饮用水 用于化学与物理检验的采样 所采水样的温度 范围：(5 – 50) °C PN-ISO 5667-5:2017-10 PN-77/C-04584","test_object_zh":"生活饮用水","methodology_zh":"用于化学与物理检验的采样 所采水样的温度 范围：(5 – 50) °C"},{"_id":"6a5a55ec9af9f73f38250209","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水"},{"_id":"6a5a55ec9af9f73f3825020a","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda podziemna","test_object_en":"Groundwater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5 – 50) °C","methodology_en":"Sampling for chemical and physical testing Temperature of the collected water sample Range: (5 – 50) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5 – 50) °C","reference":"PN-ISO 5667-11:2017-10 z wył. p. 5.2 | PN-77/C-04584","norm_bases":["PN-ISO 5667-11:2017-10 z wył. p. 5.2","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda podziemna Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5 – 50) °C PN-ISO 5667-11:2017-10 z wył. p. 5.2 | PN-77/C-04584 Woda podziemna Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody Zakres: (5 – 50) °C PN-ISO 5667-11:2017-10 z wyl. p. 5.2 | PN-77/C-04584","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Groundwater Sampling for chemical and physical testing Temperature of the collected water sample Range: (5 – 50) °C PN-ISO 5667-11:2017-10 z wył. p. 5.2 | PN-77/C-04584","search_zh":"地下水 用于化学与物理检验的采样 所采水样的温度 范围：(5 – 50) °C PN-ISO 5667-11:2017-10 z wył. p. 5.2 | PN-77/C-04584","test_object_zh":"地下水","methodology_zh":"用于化学与物理检验的采样 所采水样的温度 范围：(5 – 50) °C"},{"_id":"6a5a55ec9af9f73f3825020b","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda powierzchniowa","test_object_en":"Surface water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5 – 50) °C","methodology_en":"Sampling for chemical and physical testing Temperature of the collected water sample Range: (5 – 50) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5 – 50) °C","reference":"PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 PN-77/C-04584","norm_bases":["PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda powierzchniowa Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5 – 50) °C PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 PN-77/C-04584 Woda powierzchniowa Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody Zakres: (5 – 50) °C PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 PN-77/C-04584","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Surface water Sampling for chemical and physical testing Temperature of the collected water sample Range: (5 – 50) °C PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 PN-77/C-04584","search_zh":"地表水 用于化学与物理检验的采样 所采水样的温度 范围：(5 – 50) °C PN-ISO 5667-4:2017-10 PN-EN ISO 5667-6:2016-12 PN-77/C-04584","test_object_zh":"地表水","methodology_zh":"用于化学与物理检验的采样 所采水样的温度 范围：(5 – 50) °C"},{"_id":"6a5a55ec9af9f73f3825020c","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Ścieki Woda opadowa","test_object_en":"Wastewater Rainwater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i automatyczna Temperatura pobranej próbki ścieków Zakres: (5 – 50) °C","methodology_en":"Sampling for chemical and physical testing Manual and automatic method Temperature of the wastewater sample taken Range: (5 – 50) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i automatyczna Temperatura pobranej próbki ścieków Zakres: (5 – 50) °C","reference":"PN-ISO 5667-10:2021-11 PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Woda opadowa Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i automatyczna Temperatura pobranej próbki ścieków Zakres: (5 – 50) °C PN-ISO 5667-10:2021-11 PN-77/C-04584 Scieki Woda opadowa Pobieranie probek do badan chemicznych i fizycznych Metoda manualna i automatyczna Temperatura pobranej probki sciekow Zakres: (5 – 50) °C PN-ISO 5667-10:2021-11 PN-77/C-04584","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Rainwater Sampling for chemical and physical testing Manual and automatic method Temperature of the wastewater sample taken Range: (5 – 50) °C PN-ISO 5667-10:2021-11 PN-77/C-04584"},{"_id":"6a5a55ec9af9f73f3825020d","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Obecność obcego zapachu i smaku Metoda jakościowa","methodology_en":"Presence of foreign odour and taste Qualitative method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obecność obcego zapachu i smaku Metoda jakościowa","reference":"PN-EN 1622:2006 Załącznik C","norm_bases":["PN-EN 1622:2006 Załącznik C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Obecność obcego zapachu i smaku Metoda jakościowa PN-EN 1622:2006 Załącznik C Woda do spozycia przez ludzi Obecnosc obcego zapachu i smaku Metoda jakosciowa PN-EN 1622:2006 Zalacznik C","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Presence of foreign odour and taste Qualitative method PN-EN 1622:2006 Załącznik C","search_zh":"生活饮用水 PN-EN 1622:2006 Załącznik C","test_object_zh":"生活饮用水"},{"_id":"6a5a55ec9af9f73f3825020e","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba progowa zapachu TON Zakres: (1 – 2) Liczba progowa smaku TFN Zakres: (1 – 2) Metoda uproszczona, parzysta, wybór niewymuszony","methodology_en":"Threshold odour number TON Range: (1 – 2) Threshold flavour number TFN Range: (1 – 2) Simplified method, paired, non-forced choice","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba progowa zapachu TON Zakres: (1 – 2) Liczba progowa smaku TFN Zakres: (1 – 2) Metoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba progowa zapachu TON Zakres: (1 – 2) Liczba progowa smaku TFN Zakres: (1 – 2) Metoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa zapachu TON Zakres: (1 – 2) Liczba progowa smaku TFN Zakres: (1 – 2) Metoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Threshold odour number TON Range: (1 – 2) Threshold flavour number TFN Range: (1 – 2) Simplified method, paired, non-forced choice PN-EN 1622:2006","search_zh":"生活饮用水 PN-EN 1622:2006","test_object_zh":"生活饮用水"},{"_id":"6a5a55ec9af9f73f3825020f","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Woda na pływalniach","test_object_en":"Water Swimming pool water","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli Metoda NPL, Test Colilert 18","methodology_en":"Most probable number of coliform bacteria MPN method, Colilert 18 Test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli Metoda NPL, Test Colilert 18","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda na pływalniach Najbardziej prawdopodobna liczba bakterii grupy coli Metoda NPL, Test Colilert 18 PN-EN ISO 9308-2:2014-06 Woda Woda na plywalniach Najbardziej prawdopodobna liczba bakterii grupy coli Metoda NPL, Test Colilert 18 PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Swimming pool water Most probable number of coliform bacteria MPN method, Colilert 18 Test PN-EN ISO 9308-2:2014-06","search_zh":"水 游泳池水 PN-EN ISO 9308-2:2014-06","test_object_zh":"水 游泳池水"},{"_id":"6a5a55ec9af9f73f38250210","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Woda na pływalniach","test_object_en":"Water Swimming pool water","methodology":"Najbardziej prawdopodobna liczba Escherichia coli Metoda NPL, Test Colilert 18","methodology_en":"Most probable number of Escherichia coli MPN method, Colilert 18 Test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli Metoda NPL, Test Colilert 18","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda na pływalniach Najbardziej prawdopodobna liczba Escherichia coli Metoda NPL, Test Colilert 18 Woda Woda na plywalniach Najbardziej prawdopodobna liczba Escherichia coli Metoda NPL, Test Colilert 18","categories":["water","microbiology"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Swimming pool water Most probable number of Escherichia coli MPN method, Colilert 18 Test","search_zh":"水 游泳池水","test_object_zh":"水 游泳池水"},{"_id":"6a5a55ec9af9f73f38250211","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Woda na pływalniach","test_object_en":"Water Swimming pool water","methodology":"Najbardziej prawdopodobna liczba Pseudomonas aeruginosa Metoda NPL, Test Pseudalert","methodology_en":"Most probable number of Pseudomonas aeruginosa MPN method, Pseudalert Test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba Pseudomonas aeruginosa Metoda NPL, Test Pseudalert","reference":"PN-EN ISO 16266-2:2022-04","norm_bases":["PN-EN ISO 16266-2:2022-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda na pływalniach Najbardziej prawdopodobna liczba Pseudomonas aeruginosa Metoda NPL, Test Pseudalert PN-EN ISO 16266-2:2022-04 Woda Woda na plywalniach Najbardziej prawdopodobna liczba Pseudomonas aeruginosa Metoda NPL, Test Pseudalert PN-EN ISO 16266-2:2022-04","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Swimming pool water Most probable number of Pseudomonas aeruginosa MPN method, Pseudalert Test PN-EN ISO 16266-2:2022-04","search_zh":"水 游泳池水 PN-EN ISO 16266-2:2022-04","test_object_zh":"水 游泳池水"},{"_id":"6a5a55ec9af9f73f38250212","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Najbardziej prawdopodobna liczba enterokoków Metoda NPL, Test Enterolert E","methodology_en":"Most probable number of enterococci MPN method, Enterolert E Test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba enterokoków Metoda NPL, Test Enterolert E","reference":"Instrukcja testu IDEXX Enterolert E 2019","norm_bases":["Instrukcja testu IDEXX Enterolert E 2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Najbardziej prawdopodobna liczba enterokoków Metoda NPL, Test Enterolert E Instrukcja testu IDEXX Enterolert E 2019 Woda Najbardziej prawdopodobna liczba enterokokow Metoda NPL, Test Enterolert E Instrukcja testu IDEXX Enterolert E 2019","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Most probable number of enterococci MPN method, Enterolert E Test Instrukcja testu IDEXX Enterolert E 2019","search_zh":"水 Instrukcja testu IDEXX Enterolert E 2019","test_object_zh":"水"},{"_id":"6a5a55ec9af9f73f38250213","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Najbardziej prawdopodobna liczba enterokoków Metoda NPL, Test Enterolert DW","methodology_en":"Most probable number of enterococci MPN method, Enterolert DW Test","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba enterokoków Metoda NPL, Test Enterolert DW","reference":"Instrukcja testu IDEXX Enterolert DW 2019","norm_bases":["Instrukcja testu IDEXX Enterolert DW 2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Najbardziej prawdopodobna liczba enterokoków Metoda NPL, Test Enterolert DW Instrukcja testu IDEXX Enterolert DW 2019 Woda Najbardziej prawdopodobna liczba enterokokow Metoda NPL, Test Enterolert DW Instrukcja testu IDEXX Enterolert DW 2019","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Most probable number of enterococci MPN method, Enterolert DW Test Instrukcja testu IDEXX Enterolert DW 2019","search_zh":"水 Instrukcja testu IDEXX Enterolert DW 2019","test_object_zh":"水"},{"_id":"6a5a55ec9af9f73f38250214","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Ogólna liczba mikroorganizmów w 22 °C Metoda płytkowa, posiew wgłębny","methodology_en":"Total count of microorganisms at 22 °C Plate method, pour plate","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C Metoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ogólna liczba mikroorganizmów w 22 °C Metoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w 22 °C Metoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total count of microorganisms at 22 °C Plate method, pour plate PN-EN ISO 6222:2004","search_zh":"水 PN-EN ISO 6222:2004","test_object_zh":"水"},{"_id":"6a5a55ec9af9f73f38250215","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Ogólna liczba mikroorganizmów w 36 °C Metoda płytkowa, posiew wgłębny","methodology_en":"Total count of microorganisms at 36 °C Plate method, pour plate","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C Metoda płytkowa, posiew wgłębny","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ogólna liczba mikroorganizmów w 36 °C Metoda płytkowa, posiew wgłębny Woda Ogolna liczba mikroorganizmow w 36 °C Metoda plytkowa, posiew wglebny","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total count of microorganisms at 36 °C Plate method, pour plate","search_zh":"水","test_object_zh":"水"},{"_id":"6a5a55ec9af9f73f38250216","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Woda na pływalniach","test_object_en":"Water Swimming pool water","methodology":"Mętność Zakres: (0,10 – 50) NTU Metoda nefelometryczna","methodology_en":"Turbidity Range: (0,10 – 50) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,10 – 50) NTU Metoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda na pływalniach Mętność Zakres: (0,10 – 50) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Woda na plywalniach Metnosc Zakres: (0,10 – 50) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Swimming pool water Turbidity Range: (0,10 – 50) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","search_zh":"水 游泳池水 浊度 范围：(0,10 – 50) NTU 散射法 PN-EN ISO 7027-1:2016-09","test_object_zh":"水 游泳池水","methodology_zh":"浊度 范围：(0,10 – 50) NTU 散射法"},{"_id":"6a5a55ec9af9f73f38250217","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Barwa Zakres: (2,5 – 250) mg/l Pt Metoda wizualna","methodology_en":"Colour Range: (2,5 – 250) mg/l Pt Visual method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (2,5 – 250) mg/l Pt Metoda wizualna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Barwa Zakres: (2,5 – 250) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D Woda Barwa Zakres: (2,5 – 250) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Colour Range: (2,5 – 250) mg/l Pt Visual method PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","search_zh":"水 PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","test_object_zh":"水"},{"_id":"6a5a55ec9af9f73f38250218","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie tlenu rozpuszczonego Zakres: (1,0 – 15) mg/l O2 Metoda optyczna","methodology_en":"Dissolved oxygen concentration Range: (1,0 – 15) mg/l O2 Optical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego Zakres: (1,0 – 15) mg/l O2 Metoda optyczna","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie tlenu rozpuszczonego Zakres: (1,0 – 15) mg/l O2 Metoda optyczna ISO 17289:2014 Woda Stezenie tlenu rozpuszczonego Zakres: (1,0 – 15) mg/l O2 Metoda optyczna ISO 17289:2014","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Dissolved oxygen concentration Range: (1,0 – 15) mg/l O2 Optical method ISO 17289:2014","search_zh":"水 ISO 17289:2014","test_object_zh":"水"},{"_id":"6a5a55ec9af9f73f38250219","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie pierwiastków Zakres: Mangan (0,025 – 10,0) mg/l Żelazo (0,050 – 20,0) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","methodology_en":"Element concentrations Range: Manganese (0,025 – 10,0) mg/l Iron (0,050 – 20,0) mg/l Flame atomic absorption spectrometry method (FAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków Zakres: Mangan (0,025 – 10,0) mg/l Żelazo (0,050 – 20,0) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie pierwiastków Zakres: Mangan (0,025 – 10,0) mg/l Żelazo (0,050 – 20,0) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Woda Stezenie pierwiastkow Zakres: Mangan (0,025 – 10,0) mg/l Zelazo (0,050 – 20,0) mg/l Metoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Element concentrations Range: Manganese (0,025 – 10,0) mg/l Iron (0,050 – 20,0) mg/l Flame atomic absorption spectrometry method (FAAS) PN-ISO 8288:2002 metoda A","search_zh":"水 PN-ISO 8288:2002 metoda A","test_object_zh":"水"},{"_id":"6a5a55ec9af9f73f3825021a","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"pH Zakres: 3,0 – 12,0 Metoda potencjometryczna","methodology_en":"pH Range: 3,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 3,0 – 12,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki pH Zakres: 3,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda Scieki pH Zakres: 3,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater pH Range: 3,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水 废水 pH 范围：3,0 – 12,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水 废水","methodology_zh":"pH 范围：3,0 – 12,0 电位法"},{"_id":"6a5a55ec9af9f73f3825021b","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Przewodność elektryczna właściwa Zakres: (5,0 – 50000) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (5,0 – 50000) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (5,0 – 50000) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Przewodność elektryczna właściwa Zakres: (5,0 – 50000) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda Scieki Przewodnosc elektryczna wlasciwa Zakres: (5,0 – 50000) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Electrical conductivity Range: (5,0 – 50000) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"水 废水 PN-EN 27888:1999","test_object_zh":"水 废水"},{"_id":"6a5a55ec9af9f73f3825021c","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie jonów Zakres: Amonowy jon (0,10 – 500) mg/l Lit (0,05 – 50) mg/l Magnez (0,25 – 500) mg/l Potas (0,50 – 500) mg/l Sód (2,0 – 2000) mg/l Wapń (2,0 – 2000) mg/l Stront (0,05 – 50) mg/l Bar (0,05 – 50) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Ion concentration Range: Ammonium ion (0,10 – 500) mg/l Lithium (0,05 – 50) mg/l Magnesium (0,25 – 500) mg/l Potassium (0,50 – 500) mg/l Sodium (2,0 – 2000) mg/l Calcium (2,0 – 2000) mg/l Strontium (0,05 – 50) mg/l Barium (0,05 – 50) mg/l Ion chromatography with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonów Zakres: Amonowy jon (0,10 – 500) mg/l Lit (0,05 – 50) mg/l Magnez (0,25 – 500) mg/l Potas (0,50 – 500) mg/l Sód (2,0 – 2000) mg/l Wapń (2,0 – 2000) mg/l Stront (0,05 – 50) mg/l Bar (0,05 – 50) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie jonów Zakres: Amonowy jon (0,10 – 500) mg/l Lit (0,05 – 50) mg/l Magnez (0,25 – 500) mg/l Potas (0,50 – 500) mg/l Sód (2,0 – 2000) mg/l Wapń (2,0 – 2000) mg/l Stront (0,05 – 50) mg/l Bar (0,05 – 50) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 14911:2002 Woda Scieki Stezenie jonow Zakres: Amonowy jon (0,10 – 500) mg/l Lit (0,05 – 50) mg/l Magnez (0,25 – 500) mg/l Potas (0,50 – 500) mg/l Sod (2,0 – 2000) mg/l Wapn (2,0 – 2000) mg/l Stront (0,05 – 50) mg/l Bar (0,05 – 50) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 14911:2002","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Ion concentration Range: Ammonium ion (0,10 – 500) mg/l Lithium (0,05 – 50) mg/l Magnesium (0,25 – 500) mg/l Potassium (0,50 – 500) mg/l Sodium (2,0 – 2000) mg/l Calcium (2,0 – 2000) mg/l Strontium (0,05 – 50) mg/l Barium (0,05 – 50) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 14911:2002","search_zh":"水 废水 PN-EN ISO 14911:2002","test_object_zh":"水 废水"},{"_id":"6a5a55ec9af9f73f3825021d","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie jonów: Zakres: Azotany (0,10 – 500) mg/l Azotyny (0,050 – 200) mg/l Bromki (0,20 – 100) mg/l Chlorki (0,10 – 3000) mg/l Fluorki (0,10 – 100) mg/l Fosforany (0,05 – 500) mg/l Siarczany (0,20 – 2000) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Ion concentration: Range: Nitrates (0,10 – 500) mg/l Nitrites (0,050 – 200) mg/l Bromides (0,20 – 100) mg/l Chlorides (0,10 – 3000) mg/l Fluorides (0,10 – 100) mg/l Phosphates (0,05 – 500) mg/l Sulphates (0,20 – 2000) mg/l Ion chromatography with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonów: Zakres: Azotany (0,10 – 500) mg/l Azotyny (0,050 – 200) mg/l Bromki (0,20 – 100) mg/l Chlorki (0,10 – 3000) mg/l Fluorki (0,10 – 100) mg/l Fosforany (0,05 – 500) mg/l Siarczany (0,20 – 2000) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie jonów: Zakres: Azotany (0,10 – 500) mg/l Azotyny (0,050 – 200) mg/l Bromki (0,20 – 100) mg/l Chlorki (0,10 – 3000) mg/l Fluorki (0,10 – 100) mg/l Fosforany (0,05 – 500) mg/l Siarczany (0,20 – 2000) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda Scieki Stezenie jonow: Zakres: Azotany (0,10 – 500) mg/l Azotyny (0,050 – 200) mg/l Bromki (0,20 – 100) mg/l Chlorki (0,10 – 3000) mg/l Fluorki (0,10 – 100) mg/l Fosforany (0,05 – 500) mg/l Siarczany (0,20 – 2000) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Ion concentration: Range: Nitrates (0,10 – 500) mg/l Nitrites (0,050 – 200) mg/l Bromides (0,20 – 100) mg/l Chlorides (0,10 – 3000) mg/l Fluorides (0,10 – 100) mg/l Phosphates (0,05 – 500) mg/l Sulphates (0,20 – 2000) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","search_zh":"水 废水 PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"水 废水"},{"_id":"6a5a55ec9af9f73f3825021e","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Stężenie jonów: Zakres: Azotany (0,10 – 500) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Ion concentration: Range: Nitrates (0,10 – 500) mg/l Ion chromatography with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonów: Zakres: Azotany (0,10 – 500) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Stężenie jonów: Zakres: Azotany (0,10 – 500) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda na plywalniach Stezenie jonow: Zakres: Azotany (0,10 – 500) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Swimming pool water Ion concentration: Range: Nitrates (0,10 – 500) mg/l Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","search_zh":"游泳池水 PN-EN ISO 10304-1:2009+AC:2012","test_object_zh":"游泳池水"},{"_id":"6a5a55ec9af9f73f3825021f","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Stężenie żelaza Zakres: (0,050 – 20,0) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","methodology_en":"Iron concentration Range: (0,050 – 20,0) mg/l Flame atomic absorption spectrometry method (FAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza Zakres: (0,050 – 20,0) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Stężenie żelaza Zakres: (0,050 – 20,0) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Woda na plywalniach Stezenie zelaza Zakres: (0,050 – 20,0) mg/l Metoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Swimming pool water Iron concentration Range: (0,050 – 20,0) mg/l Flame atomic absorption spectrometry method (FAAS) PN-ISO 8288:2002 metoda A","search_zh":"游泳池水 PN-ISO 8288:2002 metoda A","test_object_zh":"游泳池水"},{"_id":"6a5a55ec9af9f73f38250220","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Woda na pływalniach Ścieki","test_object_en":"Water Swimming pool water Wastewater","methodology":"Stężenie ogólnego węgla organicznego Zakres: (0,5 – 5000) mg/l Metoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni (IR)","methodology_en":"Total organic carbon concentration Range: (0,5 – 5000) mg/l High-temperature combustion with infrared range detection (IR)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego Zakres: (0,5 – 5000) mg/l Metoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni (IR)","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda na pływalniach Ścieki Stężenie ogólnego węgla organicznego Zakres: (0,5 – 5000) mg/l Metoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni (IR) PN-EN 1484:1999 Woda Woda na plywalniach Scieki Stezenie ogolnego wegla organicznego Zakres: (0,5 – 5000) mg/l Metoda wysokotemperaturowego spalania z detekcja w zakresie podczerwieni (IR) PN-EN 1484:1999","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Swimming pool water Wastewater Total organic carbon concentration Range: (0,5 – 5000) mg/l High-temperature combustion with infrared range detection (IR) PN-EN 1484:1999"},{"_id":"6a5a55ec9af9f73f38250221","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie chromu VI Zakres: (0,001 – 200) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Chromium VI concentration Range: (0,001 – 200) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chromu VI Zakres: (0,001 – 200) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 PB-29i wydanie 1 z dnia 01.10.2020 r.","norm_bases":["PN-EN ISO 11885:2009 PB-29i wydanie 1 z dnia 01.10.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie chromu VI Zakres: (0,001 – 200) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 PB-29i wydanie 1 z dnia 01.10.2020 r. Woda Scieki Stezenie chromu VI Zakres: (0,001 – 200) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 PB-29i wydanie 1 z dnia 01.10.2020 r.","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Chromium VI concentration Range: (0,001 – 200) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009 PB-29i wydanie 1 z dnia 01.10.2020 r.","search_zh":"水 废水 PN-EN ISO 11885:2009 PB-29i wydanie 1 z dnia 01.10.2020 r.","test_object_zh":"水 废水"},{"_id":"6a5a55ec9af9f73f38250222","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie rtęci Zakres: (0,0001 – 0,10) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","methodology_en":"Mercury concentration Range: (0,0001 – 0,10) mg/l Cold vapour atomic absorption spectrometry method (CVAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,0001 – 0,10) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012-06 z wył. p. 7","norm_bases":["PN-EN ISO 12846:2012-06 z wył. p. 7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie rtęci Zakres: (0,0001 – 0,10) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012-06 z wył. p. 7 Woda Scieki Stezenie rteci Zakres: (0,0001 – 0,10) mg/l Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012-06 z wyl. p. 7","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Mercury concentration Range: (0,0001 – 0,10) mg/l Cold vapour atomic absorption spectrometry method (CVAAS) PN-EN ISO 12846:2012-06 z wył. p. 7","search_zh":"水 废水 PN-EN ISO 12846:2012-06 z wył. p. 7","test_object_zh":"水 废水"},{"_id":"6a5a55ec9af9f73f38250223","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie pierwiastków Zakres: Antymon (0,0030 – 200) mg/l Arsen (0,0050 – 200) mg/l Bar (0,00050 – 100) mg/l Bor (0,010 – 200) mg/l Beryl (0,00050 – 200) mg/l Chrom (0,0010 – 200) mg/l Cyna (0,0050 – 200) mg/l Cynk (0,0010 – 200) mg/l Glin (0,010 – 200) mg/l Kadm (0,00050 – 200) mg/l Kobalt (0,0010 – 200) mg/l Mangan (0,0010 – 200) mg/l Miedź (0,0030 – 200) mg/l Molibden (0,0050 – 200) mg/l Nikiel (0,0030 – 200) mg/l Ołów (0,0050 – 200) mg/l Rtęć (0,0050 – 100) mg/l Selen (0,0050 – 200) mg/l Srebro (0,0010 – 200) mg/l Stront (0,00050 – 100) mg/l Tal (0,0050 – 200) mg/l Tytan (0,0010 – 200) mg/l Wanad (0,0010 – 200) mg/l Żelazo (0,0030 – 200) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Element concentrations Range: Antimony (0,0030 – 200) mg/l Arsenic (0,0050 – 200) mg/l Barium (0,00050 – 100) mg/l Boron (0,010 – 200) mg/l Beryllium (0,00050 – 200) mg/l Chromium (0,0010 – 200) mg/l Tin (0,0050 – 200) mg/l Zinc (0,0010 – 200) mg/l Aluminium (0,010 – 200) mg/l Cadmium (0,00050 – 200) mg/l Cobalt (0,0010 – 200) mg/l Manganese (0,0010 – 200) mg/l Copper (0,0030 – 200) mg/l Molybdenum (0,0050 – 200) mg/l Nickel (0,0030 – 200) mg/l Lead (0,0050 – 200) mg/l Mercury (0,0050 – 100) mg/l Selenium (0,0050 – 200) mg/l Silver (0,0010 – 200) mg/l Strontium (0,00050 – 100) mg/l Thallium (0,0050 – 200) mg/l Titanium (0,0010 – 200) mg/l Vanadium (0,0010 – 200) mg/l Iron (0,0030 – 200) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków Zakres: Antymon (0,0030 – 200) mg/l Arsen (0,0050 – 200) mg/l Bar (0,00050 – 100) mg/l Bor (0,010 – 200) mg/l Beryl (0,00050 – 200) mg/l Chrom (0,0010 – 200) mg/l Cyna (0,0050 – 200) mg/l Cynk (0,0010 – 200) mg/l Glin (0,010 – 200) mg/l Kadm (0,00050 – 200) mg/l Kobalt (0,0010 – 200) mg/l Mangan (0,0010 – 200) mg/l Miedź (0,0030 – 200) mg/l Molibden (0,0050 – 200) mg/l Nikiel (0,0030 – 200) mg/l Ołów (0,0050 – 200) mg/l Rtęć (0,0050 – 100) mg/l Selen (0,0050 – 200) mg/l Srebro (0,0010 – 200) mg/l Stront (0,00050 – 100) mg/l Tal (0,0050 – 200) mg/l Tytan (0,0010 – 200) mg/l Wanad (0,0010 – 200) mg/l Żelazo (0,0030 – 200) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie pierwiastków Zakres: Antymon (0,0030 – 200) mg/l Arsen (0,0050 – 200) mg/l Bar (0,00050 – 100) mg/l Bor (0,010 – 200) mg/l Beryl (0,00050 – 200) mg/l Chrom (0,0010 – 200) mg/l Cyna (0,0050 – 200) mg/l Cynk (0,0010 – 200) mg/l Glin (0,010 – 200) mg/l Kadm (0,00050 – 200) mg/l Kobalt (0,0010 – 200) mg/l Mangan (0,0010 – 200) mg/l Miedź (0,0030 – 200) mg/l Molibden (0,0050 – 200) mg/l Nikiel (0,0030 – 200) mg/l Ołów (0,0050 – 200) mg/l Rtęć (0,0050 – 100) mg/l Selen (0,0050 – 200) mg/l Srebro (0,0010 – 200) mg/l Stront (0,00050 – 100) mg/l Tal (0,0050 – 200) mg/l Tytan (0,0010 – 200) mg/l Wanad (0,0010 – 200) mg/l Żelazo (0,0030 – 200) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda Scieki Stezenie pierwiastkow Zakres: Antymon (0,0030 – 200) mg/l Arsen (0,0050 – 200) mg/l Bar (0,00050 – 100) mg/l Bor (0,010 – 200) mg/l Beryl (0,00050 – 200) mg/l Chrom (0,0010 – 200) mg/l Cyna (0,0050 – 200) mg/l Cynk (0,0010 – 200) mg/l Glin (0,010 – 200) mg/l Kadm (0,00050 – 200) mg/l Kobalt (0,0010 – 200) mg/l Mangan (0,0010 – 200) mg/l Miedz (0,0030 – 200) mg/l Molibden (0,0050 – 200) mg/l Nikiel (0,0030 – 200) mg/l Olow (0,0050 – 200) mg/l Rtec (0,0050 – 100) mg/l Selen (0,0050 – 200) mg/l Srebro (0,0010 – 200) mg/l Stront (0,00050 – 100) mg/l Tal (0,0050 – 200) mg/l Tytan (0,0010 – 200) mg/l Wanad (0,0010 – 200) mg/l Zelazo (0,0030 – 200) mg/l Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Element concentrations Range: Antimony (0,0030 – 200) mg/l Arsenic (0,0050 – 200) mg/l Barium (0,00050 – 100) mg/l Boron (0,010 – 200) mg/l Beryllium (0,00050 – 200) mg/l Chromium (0,0010 – 200) mg/l Tin (0,0050 – 200) mg/l Zinc (0,0010 – 200) mg/l Aluminium (0,010 – 200) mg/l Cadmium (0,00050 – 200) mg/l Cobalt (0,0010 – 200) mg/l Manganese (0,0010 – 200) mg/l Copper (0,0030 – 200) mg/l Molybdenum (0,0050 – 200) mg/l Nickel (0,0030 – 200) mg/l Lead (0,0050 – 200) mg/l Mercury (0,0050 – 100) mg/l Selenium (0,0050 – 200) mg/l Silver (0,0010 – 200) mg/l Strontium (0,00050 – 100) mg/l Thallium (0,0050 – 200) mg/l Titanium (0,0010 – 200) mg/l Vanadium (0,0010 – 200) mg/l Iron (0,0030 – 200) mg/l Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009","search_zh":"水 废水 PN-EN ISO 11885:2009","test_object_zh":"水 废水"},{"_id":"6a5a55ec9af9f73f38250224","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie węglowodorów ropopochodnych Zakres: (0,05 – 100) mg/l Metoda spektrometrii w zakresie podczerwieni (IR)","methodology_en":"Concentration of petroleum hydrocarbons Range: (0,05 – 100) mg/l Infrared spectrometry method (IR)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie węglowodorów ropopochodnych Zakres: (0,05 – 100) mg/l Metoda spektrometrii w zakresie podczerwieni (IR)","reference":"PB-25b wydanie 2 z dnia 13.09.2023 r.","norm_bases":["PB-25b wydanie 2 z dnia 13.09.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie węglowodorów ropopochodnych Zakres: (0,05 – 100) mg/l Metoda spektrometrii w zakresie podczerwieni (IR) PB-25b wydanie 2 z dnia 13.09.2023 r. Woda Scieki Stezenie weglowodorow ropopochodnych Zakres: (0,05 – 100) mg/l Metoda spektrometrii w zakresie podczerwieni (IR) PB-25b wydanie 2 z dnia 13.09.2023 r.","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Concentration of petroleum hydrocarbons Range: (0,05 – 100) mg/l Infrared spectrometry method (IR) PB-25b wydanie 2 z dnia 13.09.2023 r.","search_zh":"水 废水 PB-25b wydanie 2 z dnia 13.09.2023 r.","test_object_zh":"水 废水"},{"_id":"6a5a55ec9af9f73f38250225","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5 Zakres: (1,0 – 3000) mg/l O2 Metoda optyczna","methodology_en":"Biochemical oxygen demand - BOD5 Range: (1,0 – 3000) mg/l O2 Optical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5 Zakres: (1,0 – 3000) mg/l O2 Metoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5 Zakres: (1,0 – 3000) mg/l O2 Metoda optyczna PN-EN ISO 5815-1:2019-12 Woda Scieki Biochemiczne zapotrzebowanie tlenu - BZT5 Zakres: (1,0 – 3000) mg/l O2 Metoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Biochemical oxygen demand - BOD5 Range: (1,0 – 3000) mg/l O2 Optical method PN-EN ISO 5815-1:2019-12","search_zh":"水 废水 PN-EN ISO 5815-1:2019-12","test_object_zh":"水 废水"},{"_id":"6a5a55ec9af9f73f38250226","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZTCr Zakres: (3,0 – 22000) mg/l O2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - CODCr Range: (3,0 – 22000) mg/l O2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZTCr Zakres: (3,0 – 22000) mg/l O2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Chemiczne zapotrzebowanie tlenu - ChZTCr Zakres: (3,0 – 22000) mg/l O2 Metoda spektrofotometryczna PN-ISO 15705:2005 Woda Scieki Chemiczne zapotrzebowanie tlenu - ChZTCr Zakres: (3,0 – 22000) mg/l O2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Chemical oxygen demand - CODCr Range: (3,0 – 22000) mg/l O2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"水 废水 PN-ISO 15705:2005","test_object_zh":"水 废水"},{"_id":"6a5a55ec9af9f73f38250227","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,05 – 100) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,05 – 100) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,05 – 100) mg/l Metoda spektrofotometryczna","reference":"PB-19d wydanie 2 z dnia 05.04.2022 r. na podstawie testu Nanocolor nr 0-80, 0-81, 0-76, 0-55","norm_bases":["PB-19d wydanie 2 z dnia 05.04.2022 r. na podstawie testu Nanocolor nr 0-80, 0-81, 0-76, 0-55"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie fosforu ogólnego Zakres: (0,05 – 100) mg/l Metoda spektrofotometryczna PB-19d wydanie 2 z dnia 05.04.2022 r. na podstawie testu Nanocolor nr 0-80, 0-81, 0-76, 0-55 Woda Scieki Stezenie fosforu ogolnego Zakres: (0,05 – 100) mg/l Metoda spektrofotometryczna PB-19d wydanie 2 z dnia 05.04.2022 r. na podstawie testu Nanocolor nr 0-80, 0-81, 0-76, 0-55","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total phosphorus concentration Range: (0,05 – 100) mg/l Spectrophotometric method PB-19d wydanie 2 z dnia 05.04.2022 r. na podstawie testu Nanocolor nr 0-80, 0-81, 0-76, 0-55","search_zh":"水 废水 总磷浓度 范围：(0,05 – 100) mg/l 分光光度法 PB-19d wydanie 2 z dnia 05.04.2022 r. na podstawie testu Nanocolor nr 0-80, 0-81, 0-76, 0-55","test_object_zh":"水 废水","methodology_zh":"总磷浓度 范围：(0,05 – 100) mg/l 分光光度法"},{"_id":"6a5a55ec9af9f73f38250228","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu ogólnego Zakres: (0,5 – 500) mg/l Metoda spektrofotometryczna","methodology_en":"Total nitrogen concentration Range: (0,5 – 500) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego Zakres: (0,5 – 500) mg/l Metoda spektrofotometryczna","reference":"PB-19e wydanie 2 z dnia 13.09.2023 r. na podstawie testu Nanocolor nr 0-83, 0-88, 0-92","norm_bases":["PB-19e wydanie 2 z dnia 13.09.2023 r. na podstawie testu Nanocolor nr 0-83, 0-88, 0-92"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu ogólnego Zakres: (0,5 – 500) mg/l Metoda spektrofotometryczna PB-19e wydanie 2 z dnia 13.09.2023 r. na podstawie testu Nanocolor nr 0-83, 0-88, 0-92 Woda Scieki Stezenie azotu ogolnego Zakres: (0,5 – 500) mg/l Metoda spektrofotometryczna PB-19e wydanie 2 z dnia 13.09.2023 r. na podstawie testu Nanocolor nr 0-83, 0-88, 0-92","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total nitrogen concentration Range: (0,5 – 500) mg/l Spectrophotometric method PB-19e wydanie 2 z dnia 13.09.2023 r. na podstawie testu Nanocolor nr 0-83, 0-88, 0-92","search_zh":"水 废水 PB-19e wydanie 2 z dnia 13.09.2023 r. na podstawie testu Nanocolor nr 0-83, 0-88, 0-92","test_object_zh":"水 废水"},{"_id":"6a5a55ec9af9f73f38250229","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu organicznego i azotu Kjeldahla (z obliczeń)","methodology_en":"Organic nitrogen and Kjeldahl nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu organicznego i azotu Kjeldahla (z obliczeń)","reference":"PB-19k wydanie 1 z dnia 22.09.2008 r.","norm_bases":["PB-19k wydanie 1 z dnia 22.09.2008 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu organicznego i azotu Kjeldahla (z obliczeń) PB-19k wydanie 1 z dnia 22.09.2008 r. Woda Scieki Stezenie azotu organicznego i azotu Kjeldahla (z obliczen) PB-19k wydanie 1 z dnia 22.09.2008 r.","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Organic nitrogen and Kjeldahl nitrogen concentration (calculated) PB-19k wydanie 1 z dnia 22.09.2008 r.","search_zh":"水 废水 PB-19k wydanie 1 z dnia 22.09.2008 r.","test_object_zh":"水 废水"},{"_id":"6a5a55ec9af9f73f3825022a","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Zasadowość ogólna (wodorowęglany) Zakres: (16,0 – 5000) mg/l Metoda miareczkowa","methodology_en":"Total alkalinity (hydrogen carbonates) Range: (16,0 – 5000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zasadowość ogólna (wodorowęglany) Zakres: (16,0 – 5000) mg/l Metoda miareczkowa","reference":"PN-ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-ISO 9963-1:2001+Ap1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Zasadowość ogólna (wodorowęglany) Zakres: (16,0 – 5000) mg/l Metoda miareczkowa PN-ISO 9963-1:2001+Ap1:2004 Woda Scieki Zasadowosc ogolna (wodoroweglany) Zakres: (16,0 – 5000) mg/l Metoda miareczkowa PN-ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total alkalinity (hydrogen carbonates) Range: (16,0 – 5000) mg/l Titrimetric method PN-ISO 9963-1:2001+Ap1:2004","search_zh":"水 废水 PN-ISO 9963-1:2001+Ap1:2004","test_object_zh":"水 废水"},{"_id":"6a5a55ec9af9f73f3825022b","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) (z obliczeń)","methodology_en":"Total calcium and magnesium content (total hardness) (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) (z obliczeń)","reference":"PB-09 wydanie 2 z dnia 05.08.2009 r.","norm_bases":["PB-09 wydanie 2 z dnia 05.08.2009 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Sumaryczna zawartość wapnia i magnezu (twardość ogólna) (z obliczeń) PB-09 wydanie 2 z dnia 05.08.2009 r. Woda Scieki Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna) (z obliczen) PB-09 wydanie 2 z dnia 05.08.2009 r.","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total calcium and magnesium content (total hardness) (calculated) PB-09 wydanie 2 z dnia 05.08.2009 r.","search_zh":"水 废水 钙与镁总含量（总硬度）（由计算得出） PB-09 wydanie 2 z dnia 05.08.2009 r.","test_object_zh":"水 废水","methodology_zh":"钙与镁总含量（总硬度）（由计算得出）"},{"_id":"6a5a55ec9af9f73f3825022c","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Zawiesiny ogólne Zakres: (2,0 – 1000) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (2,0 – 1000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (2,0 – 1000) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Zawiesiny ogólne Zakres: (2,0 – 1000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Woda Scieki Zawiesiny ogolne Zakres: (2,0 – 1000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total suspended solids (TSS) Range: (2,0 – 1000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"水 废水 总悬浮物 范围：(2,0 – 1000) mg/l 重量法 PN-EN 872:2007+Ap1:2007","test_object_zh":"水 废水","methodology_zh":"总悬浮物 范围：(2,0 – 1000) mg/l 重量法"},{"_id":"6a5a55ec9af9f73f3825022d","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie detergentów anionowych (anionowe substancje powierzchniowo czynne) Zakres: (0,20 − 50) mg/l Metoda spektrofotometryczna","methodology_en":"Anionic detergent concentration (anionic surfactants) Range: (0,20 − 50) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie detergentów anionowych (anionowe substancje powierzchniowo czynne) Zakres: (0,20 − 50) mg/l Metoda spektrofotometryczna","reference":"PB-26a wydanie 2 z dnia 14.06.2019 r. na podstawie testu Nanocolor nr 0-32","norm_bases":["PB-26a wydanie 2 z dnia 14.06.2019 r. na podstawie testu Nanocolor nr 0-32"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie detergentów anionowych (anionowe substancje powierzchniowo czynne) Zakres: (0,20 − 50) mg/l Metoda spektrofotometryczna PB-26a wydanie 2 z dnia 14.06.2019 r. na podstawie testu Nanocolor nr 0-32 Woda Scieki Stezenie detergentow anionowych (anionowe substancje powierzchniowo czynne) Zakres: (0,20 − 50) mg/l Metoda spektrofotometryczna PB-26a wydanie 2 z dnia 14.06.2019 r. na podstawie testu Nanocolor nr 0-32","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Anionic detergent concentration (anionic surfactants) Range: (0,20 − 50) mg/l Spectrophotometric method PB-26a wydanie 2 z dnia 14.06.2019 r. na podstawie testu Nanocolor nr 0-32","search_zh":"水 废水 PB-26a wydanie 2 z dnia 14.06.2019 r. na podstawie testu Nanocolor nr 0-32","test_object_zh":"水 废水"},{"_id":"6a5a55ec9af9f73f3825022e","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie detergentów niejonowych (niejonowe substancje powierzchniowo czynne) Zakres: (0,30 − 50) mg/l Metoda spektrofotometryczna","methodology_en":"Non-ionic detergent concentration (non-ionic surfactants) Range: (0,30 − 50) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie detergentów niejonowych (niejonowe substancje powierzchniowo czynne) Zakres: (0,30 − 50) mg/l Metoda spektrofotometryczna","reference":"PB-26l wydanie 2 z dnia 14.06.2019 r. na podstawie testu Nanocolor nr 0-47","norm_bases":["PB-26l wydanie 2 z dnia 14.06.2019 r. na podstawie testu Nanocolor nr 0-47"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie detergentów niejonowych (niejonowe substancje powierzchniowo czynne) Zakres: (0,30 − 50) mg/l Metoda spektrofotometryczna PB-26l wydanie 2 z dnia 14.06.2019 r. na podstawie testu Nanocolor nr 0-47 Woda Scieki Stezenie detergentow niejonowych (niejonowe substancje powierzchniowo czynne) Zakres: (0,30 − 50) mg/l Metoda spektrofotometryczna PB-26l wydanie 2 z dnia 14.06.2019 r. na podstawie testu Nanocolor nr 0-47","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Non-ionic detergent concentration (non-ionic surfactants) Range: (0,30 − 50) mg/l Spectrophotometric method PB-26l wydanie 2 z dnia 14.06.2019 r. na podstawie testu Nanocolor nr 0-47","search_zh":"水 废水 PB-26l wydanie 2 z dnia 14.06.2019 r. na podstawie testu Nanocolor nr 0-47","test_object_zh":"水 废水"},{"_id":"6a5a55ec9af9f73f3825022f","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie pierwiastków Zakres: Chrom (0,050 – 10,0) mg/l Cynk (0,025 – 10,0) mg/l Kadm (0,025 – 5,0) mg/l Ołów (0,100 – 20,0) mg/l Mangan (0,025 – 10,0) mg/l Miedź (0,050 – 20,0) mg/l Nikiel (0,050 – 10,0) mg/l Żelazo (0,050 – 20,0) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","methodology_en":"Element concentrations Range: Chromium (0,050 – 10,0) mg/l Zinc (0,025 – 10,0) mg/l Cadmium (0,025 – 5,0) mg/l Lead (0,100 – 20,0) mg/l Manganese (0,025 – 10,0) mg/l Copper (0,050 – 20,0) mg/l Nickel (0,050 – 10,0) mg/l Iron (0,050 – 20,0) mg/l Flame atomic absorption spectrometry method (FAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pierwiastków Zakres: Chrom (0,050 – 10,0) mg/l Cynk (0,025 – 10,0) mg/l Kadm (0,025 – 5,0) mg/l Ołów (0,100 – 20,0) mg/l Mangan (0,025 – 10,0) mg/l Miedź (0,050 – 20,0) mg/l Nikiel (0,050 – 10,0) mg/l Żelazo (0,050 – 20,0) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie pierwiastków Zakres: Chrom (0,050 – 10,0) mg/l Cynk (0,025 – 10,0) mg/l Kadm (0,025 – 5,0) mg/l Ołów (0,100 – 20,0) mg/l Mangan (0,025 – 10,0) mg/l Miedź (0,050 – 20,0) mg/l Nikiel (0,050 – 10,0) mg/l Żelazo (0,050 – 20,0) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Scieki Stezenie pierwiastkow Zakres: Chrom (0,050 – 10,0) mg/l Cynk (0,025 – 10,0) mg/l Kadm (0,025 – 5,0) mg/l Olow (0,100 – 20,0) mg/l Mangan (0,025 – 10,0) mg/l Miedz (0,050 – 20,0) mg/l Nikiel (0,050 – 10,0) mg/l Zelazo (0,050 – 20,0) mg/l Metoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["water","materials"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Element concentrations Range: Chromium (0,050 – 10,0) mg/l Zinc (0,025 – 10,0) mg/l Cadmium (0,025 – 5,0) mg/l Lead (0,100 – 20,0) mg/l Manganese (0,025 – 10,0) mg/l Copper (0,050 – 20,0) mg/l Nickel (0,050 – 10,0) mg/l Iron (0,050 – 20,0) mg/l Flame atomic absorption spectrometry method (FAAS) PN-ISO 8288:2002 metoda A","search_zh":"污水 PN-ISO 8288:2002 metoda A","test_object_zh":"污水"},{"_id":"6a5a55ec9af9f73f38250230","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 10381-4:2007 PN-EN ISO 10381-5:2009","norm_bases":["PN-EN ISO 10381-4:2007 PN-EN ISO 10381-5:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 10381-4:2007 PN-EN ISO 10381-5:2009 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 10381-4:2007 PN-EN ISO 10381-5:2009","categories":["environment"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Soil Sampling for chemical and physical testing PN-EN ISO 10381-4:2007 PN-EN ISO 10381-5:2009","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-EN ISO 10381-4:2007 PN-EN ISO 10381-5:2009","test_object_zh":"土壤"},{"_id":"6a5a55ec9af9f73f38250231","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3 Osady sciekowe Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wylaczeniem p. 6.3.3","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3","methodology_zh":"化学与物理检测用样品采集","search_zh":"污泥 化学与物理检测用样品采集 PN-EN ISO 5667-13:2011 z wyłączeniem p. 6.3.3","test_object_zh":"污泥"},{"_id":"6a5a55ec9af9f73f38250232","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Gazy składowiskowe","test_object_en":"Landfill gases","methodology":"Stężenie metanu, ditlenku węgla, tlenu Zakres: CH4 (0,5 – 65,0) % CO2 (0,5 – 40,0) % Metoda spektrometrii w podczerwieni (IR) Stężenie tlenu Zakres: (0,5 – 21,0) % Metoda elektrochemiczna Prędkość przepływu Zakres: (0,15 – 10,0) m/s Metoda termoanemometryczna","methodology_en":"Concentration of methane, carbon dioxide, oxygen Range: CH4 (0,5 – 65,0) % CO2 (0,5 – 40,0) % Infrared spectrometry method (IR) Oxygen concentration Range: (0,5 – 21,0) % Electrochemical method Flow velocity Range: (0,15 – 10,0) m/s Thermoanemometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie metanu, ditlenku węgla, tlenu Zakres: CH4 (0,5 – 65,0) % CO2 (0,5 – 40,0) % Metoda spektrometrii w podczerwieni (IR) Stężenie tlenu Zakres: (0,5 – 21,0) % Metoda elektrochemiczna Prędkość przepływu Zakres: (0,15 – 10,0) m/s Metoda termoanemometryczna","reference":"PB-27b wydanie 9 z dnia 11.09.2023 r.","norm_bases":["PB-27b wydanie 9 z dnia 11.09.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy składowiskowe Stężenie metanu, ditlenku węgla, tlenu Zakres: CH4 (0,5 – 65,0) % CO2 (0,5 – 40,0) % Metoda spektrometrii w podczerwieni (IR) Stężenie tlenu Zakres: (0,5 – 21,0) % Metoda elektrochemiczna Prędkość przepływu Zakres: (0,15 – 10,0) m/s Metoda termoanemometryczna PB-27b wydanie 9 z dnia 11.09.2023 r. Gazy skladowiskowe Stezenie metanu, ditlenku wegla, tlenu Zakres: CH4 (0,5 – 65,0) % CO2 (0,5 – 40,0) % Metoda spektrometrii w podczerwieni (IR) Stezenie tlenu Zakres: (0,5 – 21,0) % Metoda elektrochemiczna Predkosc przeplywu Zakres: (0,15 – 10,0) m/s Metoda termoanemometryczna PB-27b wydanie 9 z dnia 11.09.2023 r.","categories":["other"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Landfill gases Concentration of methane, carbon dioxide, oxygen Range: CH4 (0,5 – 65,0) % CO2 (0,5 – 40,0) % Infrared spectrometry method (IR) Oxygen concentration Range: (0,5 – 21,0) % Electrochemical method Flow velocity Range: (0,15 – 10,0) m/s Thermoanemometric method PB-27b wydanie 9 z dnia 11.09.2023 r.","search_zh":"填埋场气体 PB-27b wydanie 9 z dnia 11.09.2023 r.","test_object_zh":"填埋场气体"},{"_id":"6a5a55ec9af9f73f38250233","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Gazy składowiskowe","test_object_en":"Landfill gases","methodology":"Emisja metanu, ditlenku węgla (z obliczeń)","methodology_en":"Emission of methane, carbon dioxide (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja metanu, ditlenku węgla (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy składowiskowe Emisja metanu, ditlenku węgla (z obliczeń) Gazy skladowiskowe Emisja metanu, ditlenku wegla (z obliczen)","categories":["environment"],"row_index":43,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Landfill gases Emission of methane, carbon dioxide (calculated)","search_zh":"填埋场气体","test_object_zh":"填埋场气体"},{"_id":"6a5a55ec9af9f73f38250234","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"OdpadyDAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV) - Odpady z przetwarzania odpadów (z wyjątkiem niebezpiecznych) (VI) - Osady ściekowe (IX) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","test_object_en":"WasteDAB-11: - Sludges and mineral waste (I) - Construction waste (III) - Plant, animal and food-processing waste (IV) - Waste from waste treatment (excluding hazardous waste) (VI) - Sewage sludge (IX) - Slags, ashes and furnace dusts (XI) - Waste from the processing of crude oil, natural gas and coal (XXI) - Wood (XXVI) - Leather and textiles (XXVII) - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII)","methodology":"Zawartość jonów: Zakres: Chlorki (1,0 – 30000) mg/kg Fluorki (1,0 – 100) mg/kg Siarczany (2,0 – 20000) mg/kg Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Ion content: Range: Chlorides (1,0 – 30000) mg/kg Fluorides (1,0 – 100) mg/kg Sulphates (2,0 – 20000) mg/kg Ion chromatography method with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość jonów: Zakres: Chlorki (1,0 – 30000) mg/kg Fluorki (1,0 – 100) mg/kg Siarczany (2,0 – 20000) mg/kg Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012 PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012 PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyDAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV) - Odpady z przetwarzania odpadów (z wyjątkiem niebezpiecznych) (VI) - Osady ściekowe (IX) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość jonów: Zakres: Chlorki (1,0 – 30000) mg/kg Fluorki (1,0 – 100) mg/kg Siarczany (2,0 – 20000) mg/kg Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 PN-EN 12457-2:2006 OdpadyDAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV) - Odpady z przetwarzania odpadow (z wyjatkiem niebezpiecznych) (VI) - Osady sciekowe (IX) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc jonow: Zakres: Chlorki (1,0 – 30000) mg/kg Fluorki (1,0 – 100) mg/kg Siarczany (2,0 – 20000) mg/kg Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 PN-EN 12457-2:2006","categories":["water","environment","food","construction"],"row_index":44,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"WasteDAB-11: - Sludges and mineral waste (I) - Construction waste (III) - Plant, animal and food-processing waste (IV) - Waste from waste treatment (excluding hazardous waste) (VI) - Sewage sludge (IX) - Slags, ashes and furnace dusts (XI) - Waste from the processing of crude oil, natural gas and coal (XXI) - Wood (XXVI) - Leather and textiles (XXVII) - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII) Ion content: Range: Chlorides (1,0 – 30000) mg/kg Fluorides (1,0 – 100) mg/kg Sulphates (2,0 – 20000) mg/kg Ion chromatography method with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 PN-EN 12457-2:2006","search_zh":"废物DAB-11：－ 矿物沉积物与废物（I） － 建筑废物（III） － 植物性、动物性与食品加工废物（IV） － 废物处理产生的废物（危险废物除外）（VI） － 污水污泥（IX） － 炉渣、灰与炉膛粉尘（XI） － 石油、天然气与煤加工废物（XXI） － 木材（XXVI） － 皮革与纺织品 PN-EN ISO 10304-1:2009+AC:2012 PN-EN 12457-2:2006","test_object_zh":"废物DAB-11：－ 矿物沉积物与废物（I） － 建筑废物（III） － 植物性、动物性与食品加工废物（IV） － 废物处理产生的废物（危险废物除外）（VI） － 污水污泥（IX） － 炉渣、灰与炉膛粉尘（XI） － 石油、天然气与煤加工废物（XXI） － 木材（XXVI） － 皮革与纺织品"},{"_id":"6a5a55ec9af9f73f38250235","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"OdpadyDAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV) - Odpady z przetwarzania odpadów (z wyjątkiem niebezpiecznych) (VI) - Osady ściekowe (IX) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","test_object_en":"WasteDAB-11: - Sludges and mineral waste (I) - Construction waste (III) - Plant, animal and food-processing waste (IV) - Waste from waste treatment (excluding hazardous waste) (VI) - Sewage sludge (IX) - Slags, ashes and furnace dusts (XI) - Waste from the processing of crude oil, natural gas and coal (XXI) - Wood (XXVI) - Leather and textiles (XXVII) - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII)","methodology":"Zawartość jonów Zakres: Bar (0,5 – 50) mg/kg Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Ion content Range: Barium (0,5 – 50) mg/kg Ion chromatography method with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość jonów Zakres: Bar (0,5 – 50) mg/kg Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 14911:2002 PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 14911:2002 PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyDAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV) - Odpady z przetwarzania odpadów (z wyjątkiem niebezpiecznych) (VI) - Osady ściekowe (IX) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość jonów Zakres: Bar (0,5 – 50) mg/kg Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 14911:2002 PN-EN 12457-2:2006 OdpadyDAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV) - Odpady z przetwarzania odpadow (z wyjatkiem niebezpiecznych) (VI) - Osady sciekowe (IX) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc jonow Zakres: Bar (0,5 – 50) mg/kg Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 14911:2002 PN-EN 12457-2:2006","categories":["water","environment","food","construction"],"row_index":45,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"WasteDAB-11: - Sludges and mineral waste (I) - Construction waste (III) - Plant, animal and food-processing waste (IV) - Waste from waste treatment (excluding hazardous waste) (VI) - Sewage sludge (IX) - Slags, ashes and furnace dusts (XI) - Waste from the processing of crude oil, natural gas and coal (XXI) - Wood (XXVI) - Leather and textiles (XXVII) - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII) Ion content Range: Barium (0,5 – 50) mg/kg Ion chromatography method with conductometric detection (IC-CD) PN-EN ISO 14911:2002 PN-EN 12457-2:2006","search_zh":"废物DAB-11：－ 矿物沉积物与废物（I） － 建筑废物（III） － 植物性、动物性与食品加工废物（IV） － 废物处理产生的废物（危险废物除外）（VI） － 污水污泥（IX） － 炉渣、灰与炉膛粉尘（XI） － 石油、天然气与煤加工废物（XXI） － 木材（XXVI） － 皮革与纺织品 PN-EN ISO 14911:2002 PN-EN 12457-2:2006","test_object_zh":"废物DAB-11：－ 矿物沉积物与废物（I） － 建筑废物（III） － 植物性、动物性与食品加工废物（IV） － 废物处理产生的废物（危险废物除外）（VI） － 污水污泥（IX） － 炉渣、灰与炉膛粉尘（XI） － 石油、天然气与煤加工废物（XXI） － 木材（XXVI） － 皮革与纺织品"},{"_id":"6a5a55ec9af9f73f38250236","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"OdpadyDAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV) - Odpady z przetwarzania odpadów (z wyjątkiem niebezpiecznych) (VI) - Osady ściekowe (IX) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","test_object_en":"WasteDAB-11: - Sludges and mineral waste (I) - Construction waste (III) - Plant, animal and food-processing waste (IV) - Waste from waste treatment (excluding hazardous waste) (VI) - Sewage sludge (IX) - Slags, ashes and furnace dusts (XI) - Waste from the processing of crude oil, natural gas and coal (XXI) - Wood (XXVI) - Leather and textiles (XXVII) - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII)","methodology":"Zawartość pierwiastków Zakres: Antymon (0,05 – 2000) mg/kg Arsen (0,05 – 2000) mg/kg Bar (0,005 – 1000) mg/kg Chrom (0,01 – 2000) mg/kg Cynk (0,01 – 2000) mg/kg Kadm (0,005 – 2000) mg/kg Miedź (0,03 – 2000) mg/kg Molibden (0,05 – 2000) mg/kg Nikiel (0,03 – 2000) mg/kg Ołów (0,05– 2000) mg/kg Selen (0,05 – 2000) mg/kg Rtęć (0,05 – 1000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","methodology_en":"Content of elements Range: Antimony (0,05 – 2000) mg/kg Arsenic (0,05 – 2000) mg/kg Barium (0,005 – 1000) mg/kg Chromium (0,01 – 2000) mg/kg Zinc (0,01 – 2000) mg/kg Cadmium (0,005 – 2000) mg/kg Copper (0,03 – 2000) mg/kg Molybdenum (0,05 – 2000) mg/kg Nickel (0,03 – 2000) mg/kg Lead (0,05– 2000) mg/kg Selenium (0,05 – 2000) mg/kg Mercury (0,05 – 1000) mg/kg Inductively coupled plasma atomic emission spectrometry (ICP-OES) method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość pierwiastków Zakres: Antymon (0,05 – 2000) mg/kg Arsen (0,05 – 2000) mg/kg Bar (0,005 – 1000) mg/kg Chrom (0,01 – 2000) mg/kg Cynk (0,01 – 2000) mg/kg Kadm (0,005 – 2000) mg/kg Miedź (0,03 – 2000) mg/kg Molibden (0,05 – 2000) mg/kg Nikiel (0,03 – 2000) mg/kg Ołów (0,05– 2000) mg/kg Selen (0,05 – 2000) mg/kg Rtęć (0,05 – 1000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 PN-EN 12457-2:2006","norm_bases":["PN-EN ISO 11885:2009 PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyDAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV) - Odpady z przetwarzania odpadów (z wyjątkiem niebezpiecznych) (VI) - Osady ściekowe (IX) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość pierwiastków Zakres: Antymon (0,05 – 2000) mg/kg Arsen (0,05 – 2000) mg/kg Bar (0,005 – 1000) mg/kg Chrom (0,01 – 2000) mg/kg Cynk (0,01 – 2000) mg/kg Kadm (0,005 – 2000) mg/kg Miedź (0,03 – 2000) mg/kg Molibden (0,05 – 2000) mg/kg Nikiel (0,03 – 2000) mg/kg Ołów (0,05– 2000) mg/kg Selen (0,05 – 2000) mg/kg Rtęć (0,05 – 1000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 PN-EN 12457-2:2006 OdpadyDAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV) - Odpady z przetwarzania odpadow (z wyjatkiem niebezpiecznych) (VI) - Osady sciekowe (IX) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc pierwiastkow Zakres: Antymon (0,05 – 2000) mg/kg Arsen (0,05 – 2000) mg/kg Bar (0,005 – 1000) mg/kg Chrom (0,01 – 2000) mg/kg Cynk (0,01 – 2000) mg/kg Kadm (0,005 – 2000) mg/kg Miedz (0,03 – 2000) mg/kg Molibden (0,05 – 2000) mg/kg Nikiel (0,03 – 2000) mg/kg Olow (0,05– 2000) mg/kg Selen (0,05 – 2000) mg/kg Rtec (0,05 – 1000) mg/kg Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 PN-EN 12457-2:2006","categories":["water","environment","food","materials","construction"],"row_index":46,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"WasteDAB-11: - Sludges and mineral waste (I) - Construction waste (III) - Plant, animal and food-processing waste (IV) - Waste from waste treatment (excluding hazardous waste) (VI) - Sewage sludge (IX) - Slags, ashes and furnace dusts (XI) - Waste from the processing of crude oil, natural gas and coal (XXI) - Wood (XXVI) - Leather and textiles (XXVII) - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII) Content of elements Range: Antimony (0,05 – 2000) mg/kg Arsenic (0,05 – 2000) mg/kg Barium (0,005 – 1000) mg/kg Chromium (0,01 – 2000) mg/kg Zinc (0,01 – 2000) mg/kg Cadmium (0,005 – 2000) mg/kg Copper (0,03 – 2000) mg/kg Molybdenum (0,05 – 2000) mg/kg Nickel (0,03 – 2000) mg/kg Lead (0,05– 2000) mg/kg Selenium (0,05 – 2000) mg/kg Mercury (0,05 – 1000) mg/kg Inductively coupled plasma atomic emission spectrometry (ICP-OES) method PN-EN ISO 11885:2009 PN-EN 12457-2:2006","search_zh":"废物DAB-11：－ 矿物沉积物与废物（I） － 建筑废物（III） － 植物性、动物性与食品加工废物（IV） － 废物处理产生的废物（危险废物除外）（VI） － 污水污泥（IX） － 炉渣、灰与炉膛粉尘（XI） － 石油、天然气与煤加工废物（XXI） － 木材（XXVI） － 皮革与纺织品 PN-EN ISO 11885:2009 PN-EN 12457-2:2006","test_object_zh":"废物DAB-11：－ 矿物沉积物与废物（I） － 建筑废物（III） － 植物性、动物性与食品加工废物（IV） － 废物处理产生的废物（危险废物除外）（VI） － 污水污泥（IX） － 炉渣、灰与炉膛粉尘（XI） － 石油、天然气与煤加工废物（XXI） － 木材（XXVI） － 皮革与纺织品"},{"_id":"6a5a55ec9af9f73f38250237","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"OdpadyDAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV) - Odpady z przetwarzania odpadów (z wyjątkiem niebezpiecznych) (VI) - Osady ściekowe (IX) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","test_object_en":"WasteDAB-11: - Sludges and mineral waste (I) - Construction waste (III) - Plant, animal and food-processing waste (IV) - Waste from waste treatment (excluding hazardous waste) (VI) - Sewage sludge (IX) - Slags, ashes and furnace dusts (XI) - Waste from the processing of crude oil, natural gas and coal (XXI) - Wood (XXVI) - Leather and textiles (XXVII) - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII)","methodology":"Zawartość rtęci Zakres: (0,001 – 1) mg/kg Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","methodology_en":"Mercury content Range: (0,001 – 1) mg/kg Cold vapour atomic absorption spectrometry (CVAAS) method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość rtęci Zakres: (0,001 – 1) mg/kg Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN 12457-2:2006 PN-EN ISO 12846:2012-06 z wył. p. 7","norm_bases":["PN-EN 12457-2:2006 PN-EN ISO 12846:2012-06 z wył. p. 7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyDAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV) - Odpady z przetwarzania odpadów (z wyjątkiem niebezpiecznych) (VI) - Osady ściekowe (IX) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość rtęci Zakres: (0,001 – 1) mg/kg Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 12457-2:2006 PN-EN ISO 12846:2012-06 z wył. p. 7 OdpadyDAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV) - Odpady z przetwarzania odpadow (z wyjatkiem niebezpiecznych) (VI) - Osady sciekowe (IX) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc rteci Zakres: (0,001 – 1) mg/kg Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN 12457-2:2006 PN-EN ISO 12846:2012-06 z wyl. p. 7","categories":["water","environment","food","construction"],"row_index":47,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"WasteDAB-11: - Sludges and mineral waste (I) - Construction waste (III) - Plant, animal and food-processing waste (IV) - Waste from waste treatment (excluding hazardous waste) (VI) - Sewage sludge (IX) - Slags, ashes and furnace dusts (XI) - Waste from the processing of crude oil, natural gas and coal (XXI) - Wood (XXVI) - Leather and textiles (XXVII) - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII) Mercury content Range: (0,001 – 1) mg/kg Cold vapour atomic absorption spectrometry (CVAAS) method PN-EN 12457-2:2006 PN-EN ISO 12846:2012-06 z wył. p. 7","search_zh":"废物DAB-11：－ 矿物沉积物与废物（I） － 建筑废物（III） － 植物性、动物性与食品加工废物（IV） － 废物处理产生的废物（危险废物除外）（VI） － 污水污泥（IX） － 炉渣、灰与炉膛粉尘（XI） － 石油、天然气与煤加工废物（XXI） － 木材（XXVI） － 皮革与纺织品 PN-EN 12457-2:2006 PN-EN ISO 12846:2012-06 z wył. p. 7","test_object_zh":"废物DAB-11：－ 矿物沉积物与废物（I） － 建筑废物（III） － 植物性、动物性与食品加工废物（IV） － 废物处理产生的废物（危险废物除外）（VI） － 污水污泥（IX） － 炉渣、灰与炉膛粉尘（XI） － 石油、天然气与煤加工废物（XXI） － 木材（XXVI） － 皮革与纺织品"},{"_id":"6a5a55ec9af9f73f38250238","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"OdpadyDAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV) - Odpady z przetwarzania odpadów (z wyjątkiem niebezpiecznych) (VI) - Osady ściekowe (IX) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","test_object_en":"WasteDAB-11: - Sludges and mineral waste (I) - Construction waste (III) - Plant, animal and food-processing waste (IV) - Waste from waste treatment (excluding hazardous waste) (VI) - Sewage sludge (IX) - Slags, ashes and furnace dusts (XI) - Waste from the processing of crude oil, natural gas and coal (XXI) - Wood (XXVI) - Leather and textiles (XXVII) - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII)","methodology":"Zawartość rozpuszczonego węgla organicznego (RWO) Zakres: (5,0 – 50000) mg/kg Metoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni (IR)","methodology_en":"Content of dissolved organic carbon (DOC) Range: (5,0 – 50000) mg/kg High-temperature combustion method with infrared (IR) detection","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość rozpuszczonego węgla organicznego (RWO) Zakres: (5,0 – 50000) mg/kg Metoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni (IR)","reference":"PN-EN 1484:1999 PN-EN 12457-2:2006","norm_bases":["PN-EN 1484:1999 PN-EN 12457-2:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyDAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV) - Odpady z przetwarzania odpadów (z wyjątkiem niebezpiecznych) (VI) - Osady ściekowe (IX) - Żużle, popioły i pyły paleniskowe (XI) - Odpady z przetwórstwa ropy naftowej, gazu ziemnego i węgla (XXI) - Drewno (XXVI) - Skóry i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość rozpuszczonego węgla organicznego (RWO) Zakres: (5,0 – 50000) mg/kg Metoda wysokotemperaturowego spalania z detekcją w zakresie podczerwieni (IR) PN-EN 1484:1999 PN-EN 12457-2:2006 OdpadyDAB-11: - Osady i odpady mineralne (I) - Odpady budowlane (III) - Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV) - Odpady z przetwarzania odpadow (z wyjatkiem niebezpiecznych) (VI) - Osady sciekowe (IX) - Zuzle, popioly i pyly paleniskowe (XI) - Odpady z przetworstwa ropy naftowej, gazu ziemnego i wegla (XXI) - Drewno (XXVI) - Skory i tekstylia (XXVII) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc rozpuszczonego wegla organicznego (RWO) Zakres: (5,0 – 50000) mg/kg Metoda wysokotemperaturowego spalania z detekcja w zakresie podczerwieni (IR) PN-EN 1484:1999 PN-EN 12457-2:2006","categories":["water","environment","food","construction"],"row_index":48,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"WasteDAB-11: - Sludges and mineral waste (I) - Construction waste (III) - Plant, animal and food-processing waste (IV) - Waste from waste treatment (excluding hazardous waste) (VI) - Sewage sludge (IX) - Slags, ashes and furnace dusts (XI) - Waste from the processing of crude oil, natural gas and coal (XXI) - Wood (XXVI) - Leather and textiles (XXVII) - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII) Content of dissolved organic carbon (DOC) Range: (5,0 – 50000) mg/kg High-temperature combustion method with infrared (IR) detection PN-EN 1484:1999 PN-EN 12457-2:2006","search_zh":"废物DAB-11：－ 矿物沉积物与废物（I） － 建筑废物（III） － 植物性、动物性与食品加工废物（IV） － 废物处理产生的废物（危险废物除外）（VI） － 污水污泥（IX） － 炉渣、灰与炉膛粉尘（XI） － 石油、天然气与煤加工废物（XXI） － 木材（XXVI） － 皮革与纺织品 PN-EN 1484:1999 PN-EN 12457-2:2006","test_object_zh":"废物DAB-11：－ 矿物沉积物与废物（I） － 建筑废物（III） － 植物性、动物性与食品加工废物（IV） － 废物处理产生的废物（危险废物除外）（VI） － 污水污泥（IX） － 炉渣、灰与炉膛粉尘（XI） － 石油、天然气与煤加工废物（XXI） － 木材（XXVI） － 皮革与纺织品"},{"_id":"6a5a55ec9af9f73f38250239","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"OdpadyDAB-11: - Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV) - Odpady z przetwarzania odpadów (z wyjątkiem niebezpiecznych) (VI) - Osady ściekowe (IX) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady oczyszczania ścieków i uzdatniania wody (XXVIII)","test_object_en":"WasteDAB-11: - Plant and animal wastes and wastes from food processing (IV) - Wastes from waste treatment (excluding hazardous) (VI) - Sewage sludges (IX) - Other municipal wastes and wastes derived from municipal wastes, including mixed wastes, and other wastes from wastewater and water treatment (XXVIII)","methodology":"Ciepło spalania Zakres: (3,000 – 38,000) MJ/kg Metoda kalorymetryczna","methodology_en":"Gross calorific value Range: (3,000 – 38,000) MJ/kg Calorimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Zakres: (3,000 – 38,000) MJ/kg Metoda kalorymetryczna","reference":"PN-EN ISO 21654:2021-12","norm_bases":["PN-EN ISO 21654:2021-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyDAB-11: - Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV) - Odpady z przetwarzania odpadów (z wyjątkiem niebezpiecznych) (VI) - Osady ściekowe (IX) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady oczyszczania ścieków i uzdatniania wody (XXVIII) Ciepło spalania Zakres: (3,000 – 38,000) MJ/kg Metoda kalorymetryczna PN-EN ISO 21654:2021-12 OdpadyDAB-11: - Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV) - Odpady z przetwarzania odpadow (z wyjatkiem niebezpiecznych) (VI) - Osady sciekowe (IX) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady oczyszczania sciekow i uzdatniania wody (XXVIII) Cieplo spalania Zakres: (3,000 – 38,000) MJ/kg Metoda kalorymetryczna PN-EN ISO 21654:2021-12","categories":["water","environment","food"],"row_index":49,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"WasteDAB-11: - Plant and animal wastes and wastes from food processing (IV) - Wastes from waste treatment (excluding hazardous) (VI) - Sewage sludges (IX) - Other municipal wastes and wastes derived from municipal wastes, including mixed wastes, and other wastes from wastewater and water treatment (XXVIII) Gross calorific value Range: (3,000 – 38,000) MJ/kg Calorimetric method PN-EN ISO 21654:2021-12"},{"_id":"6a5a55ec9af9f73f3825023a","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"OdpadyDAB-11: - Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV) - Odpady z przetwarzania odpadów (z wyjątkiem niebezpiecznych) (VI) - Osady ściekowe (IX) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady oczyszczania ścieków i uzdatniania wody (XXVIII)","test_object_en":"WasteDAB-11: - Plant and animal wastes and wastes from food processing (IV) - Wastes from waste treatment (excluding hazardous) (VI) - Sewage sludges (IX) - Other municipal wastes and wastes derived from municipal wastes, including mixed wastes, and other wastes from wastewater and water treatment (XXVIII)","methodology":"Zawartość wilgoci w próbce analitycznej Zakres: (1,0 – 20,0) % Metoda wagowa","methodology_en":"Moisture content in the analytical sample Range: (1,0 – 20,0) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej Zakres: (1,0 – 20,0) % Metoda wagowa","reference":"PN-EN ISO 21660-3:2021-08","norm_bases":["PN-EN ISO 21660-3:2021-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyDAB-11: - Odpady roślinne, zwierzęce i z przetwórstwa żywności (IV) - Odpady z przetwarzania odpadów (z wyjątkiem niebezpiecznych) (VI) - Osady ściekowe (IX) - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady oczyszczania ścieków i uzdatniania wody (XXVIII) Zawartość wilgoci w próbce analitycznej Zakres: (1,0 – 20,0) % Metoda wagowa PN-EN ISO 21660-3:2021-08 OdpadyDAB-11: - Odpady roslinne, zwierzece i z przetworstwa zywnosci (IV) - Odpady z przetwarzania odpadow (z wyjatkiem niebezpiecznych) (VI) - Osady sciekowe (IX) - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady oczyszczania sciekow i uzdatniania wody (XXVIII) Zawartosc wilgoci w probce analitycznej Zakres: (1,0 – 20,0) % Metoda wagowa PN-EN ISO 21660-3:2021-08","categories":["water","environment","food"],"row_index":50,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"WasteDAB-11: - Plant and animal wastes and wastes from food processing (IV) - Wastes from waste treatment (excluding hazardous) (VI) - Sewage sludges (IX) - Other municipal wastes and wastes derived from municipal wastes, including mixed wastes, and other wastes from wastewater and water treatment (XXVIII) Moisture content in the analytical sample Range: (1,0 – 20,0) % Gravimetric method PN-EN ISO 21660-3:2021-08"},{"_id":"6a5a55ec9af9f73f3825023b","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"OdpadyDAB-11: - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII)","test_object_en":"WasteDAB-11: - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII)","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 21645:2021-09 z wył. Załącznika F i H","norm_bases":["PN-EN ISO 21645:2021-09 z wył. Załącznika F i H"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"OdpadyDAB-11: - Inne odpady komunalne i odpady pochodzące z odpadów komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania ścieków i uzdatniania wody (XXVIII) Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 21645:2021-09 z wył. Załącznika F i H OdpadyDAB-11: - Inne odpady komunalne i odpady pochodzace z odpadow komunalnych, w tym odpady zmieszane, oraz inne odpady z oczyszczania sciekow i uzdatniania wody (XXVIII) Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 21645:2021-09 z wyl. Zalacznika F i H","categories":["environment","water"],"row_index":51,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"WasteDAB-11: - Other municipal waste and waste derived from municipal waste, including mixed waste, and other waste from wastewater treatment and water treatment (XXVIII) Sampling for chemical and physical testing PN-EN ISO 21645:2021-09 z wył. Załącznika F i H","methodology_zh":"化学与物理检测用样品采集","search_zh":"化学与物理检测用样品采集 PN-EN ISO 21645:2021-09 z wył. Załącznika F i H"},{"_id":"6a5a55ec9af9f73f3825023c","lab_id":"69ad52a3de79e566650fb5c2","country":"PL","accr_number":"AB 1127","accr_body":"PCA","test_object":"Paliwa stałe: biomasa stała – biopaliwo stałe","test_object_en":"Solid fuels: solid biomass – solid biofuel","methodology":"Ciepło spalania Zakres: (5,500 – 22,800) MJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń)","methodology_en":"Gross calorific value Range: (5,500 – 22,800) MJ/kg Calorimetric method Net calorific value (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ciepło spalania Zakres: (5,500 – 22,800) MJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń)","reference":"PN-EN ISO 18125:2017-07","norm_bases":["PN-EN ISO 18125:2017-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe: biomasa stała – biopaliwo stałe Ciepło spalania Zakres: (5,500 – 22,800) MJ/kg Metoda kalorymetryczna Wartość opałowa (z obliczeń) PN-EN ISO 18125:2017-07 Paliwa stale: biomasa stala – biopaliwo stale Cieplo spalania Zakres: (5,500 – 22,800) MJ/kg Metoda kalorymetryczna Wartosc opalowa (z obliczen) PN-EN ISO 18125:2017-07","categories":["petro"],"row_index":52,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Solid fuels: solid biomass – solid biofuel Gross calorific value Range: (5,500 – 22,800) MJ/kg Calorimetric method Net calorific value (calculated) PN-EN ISO 18125:2017-07","search_zh":"固体燃料：固体生物质 – 固体生物燃料 PN-EN ISO 18125:2017-07","test_object_zh":"固体燃料：固体生物质 – 固体生物燃料"}],"has_pdf":true}