🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL
Water & wastewaterMicrobiology
PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 1126 (Gorzów Wlkp, Poland). Its accreditation scope covers 48 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Wastewater, Water, Water intended for human consumption.
At a glance
- Accreditation number: PCA AB 1126
- Methods in scope: 48
- Types of test objects: 4
- City: Gorzów Wlkp, Poland
- Accreditation number
- AB 1126
- Accreditation body
- PCA
- Address
- ul. Kosynierów Gdyńskich 47, 66-400 Gorzów Wlkp., LABORATORIUM, ul. Kostrzyńska 158
- City
- Gorzów Wlkp, Poland
What this laboratory tests (4)
- Water, water intended for human consumption — 30 methods
- Wastewater — 16 methods
- Water — 1 method
- Water intended for human consumption — 1 method
Accreditation scope — test methods (48)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing Temperature of the water sample taken Range: (5,0 – 50,0) °C | PN-ISO 5667-5:2017-10 PBL-02 wydanie 03 z dnia 16.06.2020 r. | ||
| 2 | Water | Sampling for chemical and physical testing Temperature of the water sample taken Range: (5,0 – 50,0) °C | EN ISO 5667-6:2016-12 pkt 7.4 PBL-02 wydanie 03 z dnia 16.06.2020 r. | ||
| 3 | Water, water intended for human consumption | Sampling for microbiological testing Temperature of the water sample taken Range: (5,0 – 40,0) °C | PN-EN ISO 19458:2007 pkt 4.4.1; 4.4.2 PBL-02 wydanie 03 z dnia 16.06.2020 r. | ||
| 4 | Water, water intended for human consumption | Coliform bacteria count Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | ||
| 5 | Water, water intended for human consumption | Escherichia coli count Membrane filtration method | |||
| 6 | Water, water intended for human consumption | Intestinal enterococci count Membrane filtration method | PN-EN ISO 7899-2:2004 | ||
| 7 | Water, water intended for human consumption | Total viable count at 22 °C Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 8 | Water, water intended for human consumption | Total viable count at 36 °C Plate method (pour plate) | |||
| 9 | Water, water intended for human consumption | Total iron concentration Range: (0,040 – 20) mg/l Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | ||
| 10 | Water, water intended for human consumption | Manganese concentration Range: (0,025 – 4) mg/l Spectrophotometric method | PN-92/C-04590.03 | ||
| 11 | Water, water intended for human consumption | Total calcium and magnesium concentration (total hardness) Range: (8,5 – 1000) mg/l CaCO 3 Titrimetric method | PN-ISO 6059:1999 | ||
| 12 | Water, water intended for human consumption | Calcium concentration Range: (2 – 500) mg/l Titrimetric method | PN-ISO 6058:1999 | ||
| 13 | Water, water intended for human consumption | Colour Range: (5 – 140) mg/l Pt Visual method | PN-EN ISO 7887:2012+ Ap1:2015-06 Metoda D | ||
| 14 | Water, water intended for human consumption | Colour Range: (2 – 100) mg/l Pt Spectrophotometric method | PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C | ||
| 15 | Water, water intended for human consumption | Electrical conductivity Range: (100 – 3000) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 16 | Water, water intended for human consumption | pH Range: 4,0 – 10,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 17 | Water, water intended for human consumption | Ammonium ion concentration Range: (0,05 – 12,9) mg/l Spectrophotometric method | PN-ISO 7150-1:2002 | ||
| 18 | Water, water intended for human consumption | Nitrate concentration Range: (0,44 – 100) mg/l Spectrophotometric method | PN-82/C-04576.08 | ||
| 19 | Water, water intended for human consumption | Nitrite concentration Range: (0,007 – 0,823) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 20 | Water, water intended for human consumption | Sulphate concentration Range: (20 – 400) mg/l Spectrophotometric method | PBL-25 wydanie 02 z dnia 17.10.2023 r. | ||
| 21 | Water, water intended for human consumption | Chloride concentration Range: (5,00 – 1000) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 22 | Water, water intended for human consumption | Total suspended solids Range: (2,0 – 100) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 23 | Water, water intended for human consumption | Permanganate index Range: (1,10 – 20,0) mg/l O 2 Titrimetric method | PN-EN ISO 8467:2001 | ||
| 24 | Water, water intended for human consumption | Magnesium concentration (calculated) | PN-C-04554-4:1999 zał. A | ||
| 25 | Water, water intended for human consumption | Fluoride concentration Range: (0,10 – 2,0) mg/l Spectrophotometric method | PBL-26 wydanie 01 z dnia 02.02.2023 r. | ||
| 26 | Water, water intended for human consumption | Biochemical oxygen demand - BOD 5 Range: (1,0 – 6) mg/l O 2 Electrochemical method | PN-EN 1899-2:2002 | ||
| 27 | Water, water intended for human consumption | Dissolved oxygen concentration Range: (0,15 – 10,0) mg/l Electrochemical method | PN-EN ISO 5814:2013-04 | ||
| 28 | Water, water intended for human consumption | Turbidity Range: (0,10 – 50) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 29 | Water, water intended for human consumption | Kjeldahl nitrogen concentration Range: (1,0 – 10) mg/l Titrimetric method | PN-EN 25663:2001 | ||
| 30 | Water, water intended for human consumption | Total phosphorus concentration Range: (0,022 – 5,0) mg/l Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 | ||
| 31 | Water, water intended for human consumption | Total nitrogen concentration (calculated) | PBL-17 wydanie 04 z dnia 16.06.2020 r. | ||
| 32 | Water, water intended for human consumption | Chemical oxygen demand - COD- Cr Range: (10,0 – 150) mg/l O 2 Spectrophotometric method | PN-ISO 15705:2005 | ||
| 33 | Wastewater | Sampling for chemical and physical testing Manual method Automatic method Temperature of the collected wastewater sample Range: (5,0 – 50,0) °C | PN-ISO 5667-10:2021-11 PBL-02 wydanie 03 z dnia 16.06.2020 r. | ||
| 34 | Wastewater | pH + Range: 4,0 – 10,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 35 | Wastewater | Ammonium nitrogen concentration Range: (0,04 – 10) mg/l Spectrophotometric method | PN-ISO 7150-1:2002 | ||
| 36 | Wastewater | Nitrate nitrogen concentration Range: (0,10 – 50) mg/l Spectrophotometric method | PN-82/C-04576.08 | ||
| 37 | Wastewater | Nitrite nitrogen concentration Range: (0,002 – 2,5) mg/l Spectrophotometric method | PN-EN- 26777:1999 | ||
| 38 | Wastewater | Biochemical oxygen demand - BOD 5 Range: (3,0 – 6000) mg/l O 2 Electrochemical method | PN-EN ISO 5815-1:2019-12 | ||
| 39 | Wastewater | Biochemical oxygen demand - BOD 5 Range: (1,0 – 6) mg/l O 2 Electrochemical method | PN-EN 1899-2:2002 | ||
| 40 | Wastewater | Sulphate concentration Range: (10 – 1000) mg/l Gravimetric method | PN-ISO 9280:2002 | ||
| 41 | Wastewater | Chloride concentration Range: (5,00 – 1000) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 42 | Wastewater | Total suspended solids (TSS) Range: (2,0 – 5000) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 43 | Wastewater | Total phosphorus concentration Range: (0,022 – 25) mg/l Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 | ||
| 44 | Wastewater | Ammonium nitrogen concentration Range: (0,8 – 250) mg/l Titrimetric method | PN-ISO 5664:2002 | ||
| 45 | Wastewater | Kjeldahl nitrogen concentration Range: (1,0 – 500) mg/l Titrimetric method | PN-EN 25663:2001 | ||
| 46 | Wastewater | Petroleum ether extractable substances Range: (7,4 – 190) mg/l Gravimetric method | PBL-11 wydanie 06 z dnia 16.06.2020 r. | ||
| 47 | Wastewater | Total nitrogen concentration (calculated) | PBL-17 wydanie 04 z dnia 16.06.2020 r. | ||
| 48 | Wastewater | Chemical oxygen demand - COD- Cr Range: (10,0 – 5000) mg/l O2 Spectrophotometric method | PN-ISO 15705:2005 | ||
Reference standards (36)
EN ISO 5667-6:2016-12 pkt 7.4 PBL-02 wydanie 03 z dnia 16.06.2020 r.
PBL-11 wydanie 06 z dnia 16.06.2020 r.
PBL-17 wydanie 04 z dnia 16.06.2020 r.
PBL-25 wydanie 02 z dnia 17.10.2023 r.
PBL-26 wydanie 01 z dnia 02.02.2023 r.
PN-82/C-04576.08
PN-92/C-04590.03
PN-C-04554-4:1999 zał. A
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 pkt 4.4.1; 4.4.2 PBL-02 wydanie 03 z dnia 16.06.2020 r.
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012+ Ap1:2015-06 Metoda D
PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN- 26777:1999
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11 PBL-02 wydanie 03 z dnia 16.06.2020 r.
PN-ISO 5667-5:2017-10 PBL-02 wydanie 03 z dnia 16.06.2020 r.
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994