{"lab":{"_id":"69ad52a3de79e566650fb5c0","accr_number":"AB 1126","country":"PL","accr_body":"PCA","address":"ul. Kosynierów Gdyńskich 47, 66-400 Gorzów Wlkp., LABORATORIUM, ul. Kostrzyńska 158","categories":["water","microbiology"],"city":"Gorzów Wlkp","imported_at":"2026-03-08T10:42:43.265Z","methods_count":48,"name":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1126.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo wodociągów i kanalizacji sp. z o.o. ul. kosynierów gdyńskich 47, 66-400 gorzów wlkp., laboratorium, ul. kostrzyńska 158 water microbiology other pharma electronics","status":"active","updated_at":"2026-03-08T14:50:18.243Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:18.243Z","email_confidence":"high","email_mx":true,"email_source":"https://pwik.gorzow.pl/uslugi-laboratorium_19455.html","parse_date":"2026-07-17T16:18:52.866Z","parse_source":"m5-mistral-qa","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"}],"issue":{"no":"18","date":"28.11.2025"},"map_coord":[52.741954,15.225678],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":48,"microbiology":3},"category_scores":{"water":45.18,"microbiology":0.18},"has_zh":true},"methods":[{"_id":"6a5a55ec9af9f73f382501d8","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5,0 – 50,0) °C","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken Range: (5,0 – 50,0) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5,0 – 50,0) °C","reference":"PN-ISO 5667-5:2017-10 PBL-02 wydanie 03 z dnia 16.06.2020 r.","norm_bases":["PN-ISO 5667-5:2017-10 PBL-02 wydanie 03 z dnia 16.06.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5,0 – 50,0) °C PN-ISO 5667-5:2017-10 PBL-02 wydanie 03 z dnia 16.06.2020 r. Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody Zakres: (5,0 – 50,0) °C PN-ISO 5667-5:2017-10 PBL-02 wydanie 03 z dnia 16.06.2020 r.","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature of the water sample taken Range: (5,0 – 50,0) °C PN-ISO 5667-5:2017-10 PBL-02 wydanie 03 z dnia 16.06.2020 r.","search_zh":"生活饮用水 用于化学与物理检验的采样 所采水样的温度 范围：(5,0 – 50,0) °C PN-ISO 5667-5:2017-10 PBL-02 wydanie 03 z dnia 16.06.2020 r.","test_object_zh":"生活饮用水","methodology_zh":"用于化学与物理检验的采样 所采水样的温度 范围：(5,0 – 50,0) °C"},{"_id":"6a5a55ec9af9f73f382501d9","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5,0 – 50,0) °C","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken Range: (5,0 – 50,0) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5,0 – 50,0) °C","reference":"EN ISO 5667-6:2016-12 pkt 7.4 PBL-02 wydanie 03 z dnia 16.06.2020 r.","norm_bases":["EN ISO 5667-6:2016-12 pkt 7.4 PBL-02 wydanie 03 z dnia 16.06.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (5,0 – 50,0) °C EN ISO 5667-6:2016-12 pkt 7.4 PBL-02 wydanie 03 z dnia 16.06.2020 r. Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody Zakres: (5,0 – 50,0) °C EN ISO 5667-6:2016-12 pkt 7.4 PBL-02 wydanie 03 z dnia 16.06.2020 r.","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for chemical and physical testing Temperature of the water sample taken Range: (5,0 – 50,0) °C EN ISO 5667-6:2016-12 pkt 7.4 PBL-02 wydanie 03 z dnia 16.06.2020 r.","search_zh":"水 用于化学与物理检验的采样 所采水样的温度 范围：(5,0 – 50,0) °C EN ISO 5667-6:2016-12 pkt 7.4 PBL-02 wydanie 03 z dnia 16.06.2020 r.","test_object_zh":"水","methodology_zh":"用于化学与物理检验的采样 所采水样的温度 范围：(5,0 – 50,0) °C"},{"_id":"6a5a55ec9af9f73f382501da","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych Temperatura pobranej próbki wody Zakres: (5,0 – 40,0) °C","methodology_en":"Sampling for microbiological testing Temperature of the water sample taken Range: (5,0 – 40,0) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych Temperatura pobranej próbki wody Zakres: (5,0 – 40,0) °C","reference":"PN-EN ISO 19458:2007 pkt 4.4.1; 4.4.2 PBL-02 wydanie 03 z dnia 16.06.2020 r.","norm_bases":["PN-EN ISO 19458:2007 pkt 4.4.1; 4.4.2 PBL-02 wydanie 03 z dnia 16.06.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych Temperatura pobranej próbki wody Zakres: (5,0 – 40,0) °C PN-EN ISO 19458:2007 pkt 4.4.1; 4.4.2 PBL-02 wydanie 03 z dnia 16.06.2020 r. Woda, woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych Temperatura pobranej probki wody Zakres: (5,0 – 40,0) °C PN-EN ISO 19458:2007 pkt 4.4.1; 4.4.2 PBL-02 wydanie 03 z dnia 16.06.2020 r.","categories":["water","microbiology"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Sampling for microbiological testing Temperature of the water sample taken Range: (5,0 – 40,0) °C PN-EN ISO 19458:2007 pkt 4.4.1; 4.4.2 PBL-02 wydanie 03 z dnia 16.06.2020 r.","search_zh":"水、生活饮用水 PN-EN ISO 19458:2007 pkt 4.4.1; 4.4.2 PBL-02 wydanie 03 z dnia 16.06.2020 r.","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501db","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba bakterii grupy coli Metoda filtracji membranowej","methodology_en":"Coliform bacteria count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli Metoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠菌群计数 膜过滤法","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501dc","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba Escherichia coli Metoda filtracji membranowej","methodology_en":"Escherichia coli count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Escherichia coli Metoda filtracji membranowej","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba Escherichia coli Metoda filtracji membranowej Woda, woda do spozycia przez ludzi Liczba Escherichia coli Metoda filtracji membranowej","categories":["water","microbiology"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Escherichia coli count Membrane filtration method","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数 膜过滤法","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501dd","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba enterokoków kałowych Metoda filtracji membranowej","methodology_en":"Intestinal enterococci count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych Metoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba enterokoków kałowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, woda do spozycia przez ludzi Liczba enterokokow kalowych Metoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水、生活饮用水 肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","test_object_zh":"水、生活饮用水","methodology_zh":"肠球菌计数 膜过滤法"},{"_id":"6a5a55ec9af9f73f382501de","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 22 °C Metoda płytkowa (posiew wgłębny)","methodology_en":"Total viable count at 22 °C Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C Metoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 °C Metoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 °C Metoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水、生活饮用水 22 °C 微生物总数 平板法（倾注平板） PN-EN ISO 6222:2004","test_object_zh":"水、生活饮用水","methodology_zh":"22 °C 微生物总数 平板法（倾注平板）"},{"_id":"6a5a55ec9af9f73f382501df","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 36 °C Metoda płytkowa (posiew wgłębny)","methodology_en":"Total viable count at 36 °C Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C Metoda płytkowa (posiew wgłębny)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36 °C Metoda płytkowa (posiew wgłębny) Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36 °C Metoda plytkowa (posiew wglebny)","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Total viable count at 36 °C Plate method (pour plate)","search_zh":"水、生活饮用水 36 °C 微生物总数 平板法（倾注平板）","test_object_zh":"水、生活饮用水","methodology_zh":"36 °C 微生物总数 平板法（倾注平板）"},{"_id":"6a5a55ec9af9f73f382501e0","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie żelaza ogólnego Zakres: (0,040 – 20) mg/l Metoda spektrofotometryczna","methodology_en":"Total iron concentration Range: (0,040 – 20) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego Zakres: (0,040 – 20) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza ogólnego Zakres: (0,040 – 20) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, woda do spozycia przez ludzi Stezenie zelaza ogolnego Zakres: (0,040 – 20) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Total iron concentration Range: (0,040 – 20) mg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06","search_zh":"水、生活饮用水 PN-ISO 6332:2001+Ap1:2016-06","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501e1","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie manganu Zakres: (0,025 – 4) mg/l Metoda spektrofotometryczna","methodology_en":"Manganese concentration Range: (0,025 – 4) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie manganu Zakres: (0,025 – 4) mg/l Metoda spektrofotometryczna","reference":"PN-92/C-04590.03","norm_bases":["PN-92/C-04590.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu Zakres: (0,025 – 4) mg/l Metoda spektrofotometryczna PN-92/C-04590.03 Woda, woda do spozycia przez ludzi Stezenie manganu Zakres: (0,025 – 4) mg/l Metoda spektrofotometryczna PN-92/C-04590.03","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Manganese concentration Range: (0,025 – 4) mg/l Spectrophotometric method PN-92/C-04590.03","search_zh":"水、生活饮用水 PN-92/C-04590.03","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501e2","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Sumaryczne stężenie wapnia i magnezu (twardość ogólna) Zakres: (8,5 – 1000) mg/l CaCO 3 Metoda miareczkowa","methodology_en":"Total calcium and magnesium concentration (total hardness) Range: (8,5 – 1000) mg/l CaCO 3 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sumaryczne stężenie wapnia i magnezu (twardość ogólna) Zakres: (8,5 – 1000) mg/l CaCO 3 Metoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Sumaryczne stężenie wapnia i magnezu (twardość ogólna) Zakres: (8,5 – 1000) mg/l CaCO 3 Metoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Sumaryczne stezenie wapnia i magnezu (twardosc ogolna) Zakres: (8,5 – 1000) mg/l CaCO 3 Metoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Total calcium and magnesium concentration (total hardness) Range: (8,5 – 1000) mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999","search_zh":"水、生活饮用水 PN-ISO 6059:1999","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501e3","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie wapnia Zakres: (2 – 500) mg/l Metoda miareczkowa","methodology_en":"Calcium concentration Range: (2 – 500) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie wapnia Zakres: (2 – 500) mg/l Metoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie wapnia Zakres: (2 – 500) mg/l Metoda miareczkowa PN-ISO 6058:1999 Woda, woda do spozycia przez ludzi Stezenie wapnia Zakres: (2 – 500) mg/l Metoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Calcium concentration Range: (2 – 500) mg/l Titrimetric method PN-ISO 6058:1999","search_zh":"水、生活饮用水 PN-ISO 6058:1999","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501e4","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Barwa Zakres: (5 – 140) mg/l Pt Metoda wizualna","methodology_en":"Colour Range: (5 – 140) mg/l Pt Visual method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (5 – 140) mg/l Pt Metoda wizualna","reference":"PN-EN ISO 7887:2012+ Ap1:2015-06 Metoda D","norm_bases":["PN-EN ISO 7887:2012+ Ap1:2015-06 Metoda D"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Barwa Zakres: (5 – 140) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012+ Ap1:2015-06 Metoda D Woda, woda do spozycia przez ludzi Barwa Zakres: (5 – 140) mg/l Pt Metoda wizualna PN-EN ISO 7887:2012+ Ap1:2015-06 Metoda D","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Colour Range: (5 – 140) mg/l Pt Visual method PN-EN ISO 7887:2012+ Ap1:2015-06 Metoda D","search_zh":"水、生活饮用水 PN-EN ISO 7887:2012+ Ap1:2015-06 Metoda D","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501e5","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Barwa Zakres: (2 – 100) mg/l Pt Metoda spektrofotometryczna","methodology_en":"Colour Range: (2 – 100) mg/l Pt Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (2 – 100) mg/l Pt Metoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Barwa Zakres: (2 – 100) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C Woda, woda do spozycia przez ludzi Barwa Zakres: (2 – 100) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Colour Range: (2 – 100) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","search_zh":"水、生活饮用水 色度 范围：(2 – 100) mg/l Pt 分光光度法 PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","test_object_zh":"水、生活饮用水","methodology_zh":"色度 范围：(2 – 100) mg/l Pt 分光光度法"},{"_id":"6a5a55ec9af9f73f382501e6","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Przewodność elektryczna właściwa Zakres: (100 – 3000) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (100 – 3000) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (100 – 3000) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa Zakres: (100 – 3000) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa Zakres: (100 – 3000) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Electrical conductivity Range: (100 – 3000) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"水、生活饮用水 电导率 范围：(100 – 3000) µS/cm 电导法 PN-EN 27888:1999","test_object_zh":"水、生活饮用水","methodology_zh":"电导率 范围：(100 – 3000) µS/cm 电导法"},{"_id":"6a5a55ec9af9f73f382501e7","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 4,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 4,0 – 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi pH Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水、生活饮用水 pH 范围：4,0 – 10,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水、生活饮用水","methodology_zh":"pH 范围：4,0 – 10,0 电位法"},{"_id":"6a5a55ec9af9f73f382501e8","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie jonu amonowego Zakres: (0,05 – 12,9) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium ion concentration Range: (0,05 – 12,9) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego Zakres: (0,05 – 12,9) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jonu amonowego Zakres: (0,05 – 12,9) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, woda do spozycia przez ludzi Stezenie jonu amonowego Zakres: (0,05 – 12,9) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Ammonium ion concentration Range: (0,05 – 12,9) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"水、生活饮用水 PN-ISO 7150-1:2002","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501e9","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotanów Zakres: (0,44 – 100) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate concentration Range: (0,44 – 100) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotanów Zakres: (0,44 – 100) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotanów Zakres: (0,44 – 100) mg/l Metoda spektrofotometryczna PN-82/C-04576.08 Woda, woda do spozycia przez ludzi Stezenie azotanow Zakres: (0,44 – 100) mg/l Metoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Nitrate concentration Range: (0,44 – 100) mg/l Spectrophotometric method PN-82/C-04576.08","search_zh":"水、生活饮用水 PN-82/C-04576.08","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501ea","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotynów Zakres: (0,007 – 0,823) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite concentration Range: (0,007 – 0,823) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów Zakres: (0,007 – 0,823) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotynów Zakres: (0,007 – 0,823) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi Stezenie azotynow Zakres: (0,007 – 0,823) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Nitrite concentration Range: (0,007 – 0,823) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水、生活饮用水 PN-EN 26777:1999","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501eb","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie siarczanów Zakres: (20 – 400) mg/l Metoda spektrofotometryczna","methodology_en":"Sulphate concentration Range: (20 – 400) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów Zakres: (20 – 400) mg/l Metoda spektrofotometryczna","reference":"PBL-25 wydanie 02 z dnia 17.10.2023 r.","norm_bases":["PBL-25 wydanie 02 z dnia 17.10.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie siarczanów Zakres: (20 – 400) mg/l Metoda spektrofotometryczna PBL-25 wydanie 02 z dnia 17.10.2023 r. Woda, woda do spozycia przez ludzi Stezenie siarczanow Zakres: (20 – 400) mg/l Metoda spektrofotometryczna PBL-25 wydanie 02 z dnia 17.10.2023 r.","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Sulphate concentration Range: (20 – 400) mg/l Spectrophotometric method PBL-25 wydanie 02 z dnia 17.10.2023 r.","search_zh":"水、生活饮用水 PBL-25 wydanie 02 z dnia 17.10.2023 r.","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501ec","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie chlorków Zakres: (5,00 – 1000) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5,00 – 1000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,00 – 1000) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chlorków Zakres: (5,00 – 1000) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi Stezenie chlorkow Zakres: (5,00 – 1000) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Chloride concentration Range: (5,00 – 1000) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水、生活饮用水 氯化物浓度 范围：(5,00 – 1000) mg/l 滴定法 PN-ISO 9297:1994","test_object_zh":"水、生活饮用水","methodology_zh":"氯化物浓度 范围：(5,00 – 1000) mg/l 滴定法"},{"_id":"6a5a55ec9af9f73f382501ed","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Zawiesiny ogólne Zakres: (2,0 – 100) mg/l Metoda wagowa","methodology_en":"Total suspended solids Range: (2,0 – 100) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (2,0 – 100) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Zawiesiny ogólne Zakres: (2,0 – 100) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Woda, woda do spozycia przez ludzi Zawiesiny ogolne Zakres: (2,0 – 100) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Total suspended solids Range: (2,0 – 100) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"水、生活饮用水 PN-EN 872:2007+Ap1:2007","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501ee","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Indeks nadmanganianowy Zakres: (1,10 – 20,0) mg/l O 2 Metoda miareczkowa","methodology_en":"Permanganate index Range: (1,10 – 20,0) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy Zakres: (1,10 – 20,0) mg/l O 2 Metoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Indeks nadmanganianowy Zakres: (1,10 – 20,0) mg/l O 2 Metoda miareczkowa PN-EN ISO 8467:2001 Woda, woda do spozycia przez ludzi Indeks nadmanganianowy Zakres: (1,10 – 20,0) mg/l O 2 Metoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Permanganate index Range: (1,10 – 20,0) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001","search_zh":"水、生活饮用水 PN-EN ISO 8467:2001","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501ef","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie magnezu (z obliczeń)","methodology_en":"Magnesium concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999 zał. A","norm_bases":["PN-C-04554-4:1999 zał. A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-C-04554-4:1999 zał. A Woda, woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-C-04554-4:1999 zal. A","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Magnesium concentration (calculated) PN-C-04554-4:1999 zał. A","search_zh":"水、生活饮用水 镁浓度（计算值） PN-C-04554-4:1999 zał. A","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a5a55ec9af9f73f382501f0","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie fluorków Zakres: (0,10 – 2,0) mg/l Metoda spektrofotometryczna","methodology_en":"Fluoride concentration Range: (0,10 – 2,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fluorków Zakres: (0,10 – 2,0) mg/l Metoda spektrofotometryczna","reference":"PBL-26 wydanie 01 z dnia 02.02.2023 r.","norm_bases":["PBL-26 wydanie 01 z dnia 02.02.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie fluorków Zakres: (0,10 – 2,0) mg/l Metoda spektrofotometryczna PBL-26 wydanie 01 z dnia 02.02.2023 r. Woda, woda do spozycia przez ludzi Stezenie fluorkow Zakres: (0,10 – 2,0) mg/l Metoda spektrofotometryczna PBL-26 wydanie 01 z dnia 02.02.2023 r.","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Fluoride concentration Range: (0,10 – 2,0) mg/l Spectrophotometric method PBL-26 wydanie 01 z dnia 02.02.2023 r.","search_zh":"水、生活饮用水 PBL-26 wydanie 01 z dnia 02.02.2023 r.","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501f1","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (1,0 – 6) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002 Woda, woda do spozycia przez ludzi Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Biochemical oxygen demand - BOD 5 Range: (1,0 – 6) mg/l O 2 Electrochemical method PN-EN 1899-2:2002","search_zh":"水、生活饮用水 PN-EN 1899-2:2002","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501f2","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie tlenu rozpuszczonego Zakres: (0,15 – 10,0) mg/l Metoda elektrochemiczna","methodology_en":"Dissolved oxygen concentration Range: (0,15 – 10,0) mg/l Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego Zakres: (0,15 – 10,0) mg/l Metoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie tlenu rozpuszczonego Zakres: (0,15 – 10,0) mg/l Metoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda, woda do spozycia przez ludzi Stezenie tlenu rozpuszczonego Zakres: (0,15 – 10,0) mg/l Metoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Dissolved oxygen concentration Range: (0,15 – 10,0) mg/l Electrochemical method PN-EN ISO 5814:2013-04","search_zh":"水、生活饮用水 PN-EN ISO 5814:2013-04","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501f3","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Mętność Zakres: (0,10 – 50) NTU Metoda nefelometryczna","methodology_en":"Turbidity Range: (0,10 – 50) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,10 – 50) NTU Metoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Mętność Zakres: (0,10 – 50) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc Zakres: (0,10 – 50) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Turbidity Range: (0,10 – 50) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","search_zh":"水、生活饮用水 浊度 范围：(0,10 – 50) NTU 散射法 PN-EN ISO 7027-1:2016-09","test_object_zh":"水、生活饮用水","methodology_zh":"浊度 范围：(0,10 – 50) NTU 散射法"},{"_id":"6a5a55ec9af9f73f382501f4","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotu Kjeldahla Zakres: (1,0 – 10) mg/l Metoda miareczkowa","methodology_en":"Kjeldahl nitrogen concentration Range: (1,0 – 10) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (1,0 – 10) mg/l Metoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotu Kjeldahla Zakres: (1,0 – 10) mg/l Metoda miareczkowa PN-EN 25663:2001 Woda, woda do spozycia przez ludzi Stezenie azotu Kjeldahla Zakres: (1,0 – 10) mg/l Metoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Kjeldahl nitrogen concentration Range: (1,0 – 10) mg/l Titrimetric method PN-EN 25663:2001","search_zh":"水、生活饮用水 PN-EN 25663:2001","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501f5","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie fosforu ogólnego Zakres: (0,022 – 5,0) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,022 – 5,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,022 – 5,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie fosforu ogólnego Zakres: (0,022 – 5,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 Woda, woda do spozycia przez ludzi Stezenie fosforu ogolnego Zakres: (0,022 – 5,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Total phosphorus concentration Range: (0,022 – 5,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","search_zh":"水、生活饮用水 PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501f6","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PBL-17 wydanie 04 z dnia 16.06.2020 r.","norm_bases":["PBL-17 wydanie 04 z dnia 16.06.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotu ogólnego (z obliczeń) PBL-17 wydanie 04 z dnia 16.06.2020 r. Woda, woda do spozycia przez ludzi Stezenie azotu ogolnego (z obliczen) PBL-17 wydanie 04 z dnia 16.06.2020 r.","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Total nitrogen concentration (calculated) PBL-17 wydanie 04 z dnia 16.06.2020 r.","methodology_zh":"总氮浓度（计算值）","search_zh":"水、生活饮用水 总氮浓度（计算值） PBL-17 wydanie 04 z dnia 16.06.2020 r.","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501f7","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT- Cr Zakres: (10,0 – 150) mg/l O 2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD- Cr Range: (10,0 – 150) mg/l O 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT- Cr Zakres: (10,0 – 150) mg/l O 2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Chemiczne zapotrzebowanie tlenu - ChZT- Cr Zakres: (10,0 – 150) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005 Woda, woda do spozycia przez ludzi Chemiczne zapotrzebowanie tlenu - ChZT- Cr Zakres: (10,0 – 150) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, water intended for human consumption Chemical oxygen demand - COD- Cr Range: (10,0 – 150) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"水、生活饮用水 PN-ISO 15705:2005","test_object_zh":"水、生活饮用水"},{"_id":"6a5a55ec9af9f73f382501f8","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura pobranej próbki ścieków Zakres: (5,0 – 50,0) °C","methodology_en":"Sampling for chemical and physical testing Manual method Automatic method Temperature of the collected wastewater sample Range: (5,0 – 50,0) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura pobranej próbki ścieków Zakres: (5,0 – 50,0) °C","reference":"PN-ISO 5667-10:2021-11 PBL-02 wydanie 03 z dnia 16.06.2020 r.","norm_bases":["PN-ISO 5667-10:2021-11 PBL-02 wydanie 03 z dnia 16.06.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura pobranej próbki ścieków Zakres: (5,0 – 50,0) °C PN-ISO 5667-10:2021-11 PBL-02 wydanie 03 z dnia 16.06.2020 r. Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura pobranej probki sciekow Zakres: (5,0 – 50,0) °C PN-ISO 5667-10:2021-11 PBL-02 wydanie 03 z dnia 16.06.2020 r.","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing Manual method Automatic method Temperature of the collected wastewater sample Range: (5,0 – 50,0) °C PN-ISO 5667-10:2021-11 PBL-02 wydanie 03 z dnia 16.06.2020 r.","search_zh":"污水 用于化学与物理检验的采样 手工法 自动法 所采废水样品的温度 范围：(5,0 – 50,0) °C PN-ISO 5667-10:2021-11 PBL-02 wydanie 03 z dnia 16.06.2020 r.","test_object_zh":"污水","methodology_zh":"用于化学与物理检验的采样 手工法 自动法 所采废水样品的温度 范围：(5,0 – 50,0) °C"},{"_id":"6a5a55ec9af9f73f382501f9","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH +  Zakres: 4,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH +  Range: 4,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH +  Zakres: 4,0 – 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH +  Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH +  Zakres: 4,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater pH +  Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"污水 PN-EN ISO 10523:2012","test_object_zh":"污水"},{"_id":"6a5a55ec9af9f73f382501fa","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,04 – 10) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen concentration Range: (0,04 – 10) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,04 – 10) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego Zakres: (0,04 – 10) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki Stezenie azotu amonowego Zakres: (0,04 – 10) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Ammonium nitrogen concentration Range: (0,04 – 10) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"污水 PN-ISO 7150-1:2002","test_object_zh":"污水"},{"_id":"6a5a55ec9af9f73f382501fb","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotanowego Zakres: (0,10 – 50) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate nitrogen concentration Range: (0,10 – 50) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego Zakres: (0,10 – 50) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotanowego Zakres: (0,10 – 50) mg/l Metoda spektrofotometryczna PN-82/C-04576.08 Scieki Stezenie azotu azotanowego Zakres: (0,10 – 50) mg/l Metoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Nitrate nitrogen concentration Range: (0,10 – 50) mg/l Spectrophotometric method PN-82/C-04576.08","search_zh":"污水 PN-82/C-04576.08","test_object_zh":"污水"},{"_id":"6a5a55ec9af9f73f382501fc","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu azotynowego Zakres: (0,002 – 2,5) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,002 – 2,5) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,002 – 2,5) mg/l Metoda spektrofotometryczna","reference":"PN-EN- 26777:1999","norm_bases":["PN-EN- 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu azotynowego Zakres: (0,002 – 2,5) mg/l Metoda spektrofotometryczna PN-EN- 26777:1999 Scieki Stezenie azotu azotynowego Zakres: (0,002 – 2,5) mg/l Metoda spektrofotometryczna PN-EN- 26777:1999","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Nitrite nitrogen concentration Range: (0,002 – 2,5) mg/l Spectrophotometric method PN-EN- 26777:1999","search_zh":"污水 PN-EN- 26777:1999","test_object_zh":"污水"},{"_id":"6a5a55ec9af9f73f382501fd","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3,0 – 6000) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (3,0 – 6000) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3,0 – 6000) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3,0 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3,0 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Biochemical oxygen demand - BOD 5 Range: (3,0 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12","search_zh":"污水 五日生化需氧量 BZT 5 范围：(3,0 – 6000) mg/l O 2 电化学法 PN-EN ISO 5815-1:2019-12","test_object_zh":"污水","methodology_zh":"五日生化需氧量 BZT 5 范围：(3,0 – 6000) mg/l O 2 电化学法"},{"_id":"6a5a55ec9af9f73f382501fe","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (1,0 – 6) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002 Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Biochemical oxygen demand - BOD 5 Range: (1,0 – 6) mg/l O 2 Electrochemical method PN-EN 1899-2:2002","search_zh":"污水 PN-EN 1899-2:2002","test_object_zh":"污水"},{"_id":"6a5a55ec9af9f73f382501ff","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie siarczanów Zakres: (10 – 1000) mg/l Metoda wagowa","methodology_en":"Sulphate concentration Range: (10 – 1000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów Zakres: (10 – 1000) mg/l Metoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie siarczanów Zakres: (10 – 1000) mg/l Metoda wagowa PN-ISO 9280:2002 Scieki Stezenie siarczanow Zakres: (10 – 1000) mg/l Metoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sulphate concentration Range: (10 – 1000) mg/l Gravimetric method PN-ISO 9280:2002","search_zh":"污水 硫酸盐浓度 范围：(10 – 1000) mg/l 重量法 PN-ISO 9280:2002","test_object_zh":"污水","methodology_zh":"硫酸盐浓度 范围：(10 – 1000) mg/l 重量法"},{"_id":"6a5a55ec9af9f73f38250200","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chlorków Zakres: (5,00 – 1000) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5,00 – 1000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,00 – 1000) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chlorków Zakres: (5,00 – 1000) mg/l Metoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow Zakres: (5,00 – 1000) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Chloride concentration Range: (5,00 – 1000) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"污水 氯化物浓度 范围：(5,00 – 1000) mg/l 滴定法 PN-ISO 9297:1994","test_object_zh":"污水","methodology_zh":"氯化物浓度 范围：(5,00 – 1000) mg/l 滴定法"},{"_id":"6a5a55ec9af9f73f38250201","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne Zakres: (2,0 – 5000) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (2,0 – 5000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (2,0 – 5000) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne Zakres: (2,0 – 5000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne Zakres: (2,0 – 5000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total suspended solids (TSS) Range: (2,0 – 5000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"污水 总悬浮物 范围：(2,0 – 5000) mg/l 重量法 PN-EN 872:2007+Ap1:2007","test_object_zh":"污水","methodology_zh":"总悬浮物 范围：(2,0 – 5000) mg/l 重量法"},{"_id":"6a5a55ec9af9f73f38250202","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,022 – 25) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,022 – 25) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,022 – 25) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego Zakres: (0,022 – 25) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010 Scieki Stezenie fosforu ogolnego Zakres: (0,022 – 25) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total phosphorus concentration Range: (0,022 – 25) mg/l Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","search_zh":"污水 PN-EN ISO 6878:2006+Ap1:2010+Ap2:2010","test_object_zh":"污水"},{"_id":"6a5a55ec9af9f73f38250203","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,8 – 250) mg/l Metoda miareczkowa","methodology_en":"Ammonium nitrogen concentration Range: (0,8 – 250) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,8 – 250) mg/l Metoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego Zakres: (0,8 – 250) mg/l Metoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego Zakres: (0,8 – 250) mg/l Metoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Ammonium nitrogen concentration Range: (0,8 – 250) mg/l Titrimetric method PN-ISO 5664:2002","search_zh":"污水 PN-ISO 5664:2002","test_object_zh":"污水"},{"_id":"6a5a55ec9af9f73f38250204","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu Kjeldahla Zakres: (1,0 – 500) mg/l Metoda miareczkowa","methodology_en":"Kjeldahl nitrogen concentration Range: (1,0 – 500) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (1,0 – 500) mg/l Metoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu Kjeldahla Zakres: (1,0 – 500) mg/l Metoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla Zakres: (1,0 – 500) mg/l Metoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Kjeldahl nitrogen concentration Range: (1,0 – 500) mg/l Titrimetric method PN-EN 25663:2001","search_zh":"污水 凯氏氮浓度 范围：(1,0 – 500) mg/l 滴定法 PN-EN 25663:2001","test_object_zh":"污水","methodology_zh":"凯氏氮浓度 范围：(1,0 – 500) mg/l 滴定法"},{"_id":"6a5a55ec9af9f73f38250205","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Substancje ekstrahujące się eterem naftowym Zakres: (7,4 – 190) mg/l Metoda wagowa","methodology_en":"Petroleum ether extractable substances Range: (7,4 – 190) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Substancje ekstrahujące się eterem naftowym Zakres: (7,4 – 190) mg/l Metoda wagowa","reference":"PBL-11 wydanie 06 z dnia 16.06.2020 r.","norm_bases":["PBL-11 wydanie 06 z dnia 16.06.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Substancje ekstrahujące się eterem naftowym Zakres: (7,4 – 190) mg/l Metoda wagowa PBL-11 wydanie 06 z dnia 16.06.2020 r. Scieki Substancje ekstrahujace sie eterem naftowym Zakres: (7,4 – 190) mg/l Metoda wagowa PBL-11 wydanie 06 z dnia 16.06.2020 r.","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Petroleum ether extractable substances Range: (7,4 – 190) mg/l Gravimetric method PBL-11 wydanie 06 z dnia 16.06.2020 r.","search_zh":"污水 PBL-11 wydanie 06 z dnia 16.06.2020 r.","test_object_zh":"污水"},{"_id":"6a5a55ec9af9f73f38250206","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PBL-17 wydanie 04 z dnia 16.06.2020 r.","norm_bases":["PBL-17 wydanie 04 z dnia 16.06.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PBL-17 wydanie 04 z dnia 16.06.2020 r. Scieki Stezenie azotu ogolnego (z obliczen) PBL-17 wydanie 04 z dnia 16.06.2020 r.","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total nitrogen concentration (calculated) PBL-17 wydanie 04 z dnia 16.06.2020 r.","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） PBL-17 wydanie 04 z dnia 16.06.2020 r.","test_object_zh":"污水"},{"_id":"6a5a55ec9af9f73f38250207","lab_id":"69ad52a3de79e566650fb5c0","country":"PL","accr_number":"AB 1126","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT- Cr Zakres: (10,0 – 5000) mg/l O2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD- Cr Range: (10,0 – 5000) mg/l O2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT- Cr Zakres: (10,0 – 5000) mg/l O2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT- Cr Zakres: (10,0 – 5000) mg/l O2 Metoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - ChZT- Cr Zakres: (10,0 – 5000) mg/l O2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Chemical oxygen demand - COD- Cr Range: (10,0 – 5000) mg/l O2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"污水 PN-ISO 15705:2005","test_object_zh":"污水"}],"has_pdf":true}