🇵🇱 PRO-INFO s.c. PL

PCA AB 1121 • Bielsko-Biała, Poland • 46 methods

EnvironmentElectronics & EMC

PRO-INFO s.c. is a laboratory accredited by PCA under number AB 1121 (Bielsko-Biała, Poland). Its accreditation scope covers 46 test methods in the following areas: Environment, Electronics & EMC. Test objects include: Workplace environment − air, Workplace environment - electromagnetic field from equipment used i…, Workplace environment − electromagnetic field from industrial insta…, Workplace environment - electromagnetic field in the workspace duri…. Most frequently used techniques: Direct measurement method, Gravimetric method, Electrochemical method.

At a glance

  • Accreditation number: PCA AB 1121
  • Methods in scope: 46
  • Types of test objects: 16
  • Techniques used: 5
  • City: Bielsko-Biała, Poland
Accreditation number
AB 1121
Accreditation body
PCA
Address
Wojciech Kliś, Maciej Kliś, ZAKŁAD BADAŃ ŚRODOWISKA, ul. Wita Stwosza 11b, 43-300 Bielsko-Biała
City
Bielsko-Biała, Poland

What this laboratory tests (16)

Analytical techniques used (5)

Laboratory locations

Accreditation scope — test methods (46)

No. Test object Methodology / Parameters Technique Reference document
Zakład Badań Środowiska
1 Workplace environment − air Air sampling for occupational exposure assessment to:
dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction metals and their compounds, including – inhalable fraction – respirable fraction asbestos respirable fibres man-made mineral fibres, excluding refractory ceramic fibres respirable fibres respirabilne włókna ceramiczne
Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
2 Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004
3 Workplace environment − air Air sampling for occupational exposure assessment to:
inorganic substances, including – inhalable fraction – thoracic fraction – respirable fraction
Stationary method; Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
4 Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004
5 Workplace environment − air Concentration of harmful dust agents - inhalable fraction
Apatites and phosphorites Petroleum bitumen Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,07 – 17) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
6 Workplace environment − air Concentration of dust agents harmful to health- respirable fraction
Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range (0,07 - 17) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
7 Workplace environment − air Carbon monoxide concentration
Range (2,3 – 272 mg/m3 Range (2,0 – 235) ppm
Electrochemical method Procedura Badawcza PB-04 wydanie 11 z dnia 26.05.2026 r.
8 Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (22-137) dB C-weighted peak sound pressure level Range (30-140) dB
Direct measurement method PN-94/N-01307 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - pkt 10
9 Workplace environment − noise Noise exposure level normalised to: (calculated)
an 8-hour daily working time average weekly working time
PN-94/N-01307 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - pkt 10
10 Workplace environment − indoor electric lighting Illuminance
Range (5 – 9000) lx
Direct measurement method PN-83/E-04040.03 | Procedura Badawcza PB-03 wydanie 6 z dnia 28.02.2025 r.
11 Workplace environment − indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03 | Procedura Badawcza PB-03 wydanie 6 z dnia 28.02.2025 r.
12 Workplace environment − emergency lighting Illuminance
Range (0,5 – 500) lx
Direct measurement method PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
13 Workplace environment − emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
14 Workplace environment − emergency lighting Illuminance uniformity for the high-risk zone (calculated) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
15 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (22-136) dB
Direct measurement method Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F
16 General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F
17 Workplace environment − hand-arm vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,3 – 100) m/s2
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
18 Workplace environment − hand-arm vibration Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 – godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)., Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11
19 Workplace environment − whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,03 – 10) m/s2
Direct measurement method PN-EN 14253+A1:2011
20 Workplace environment − whole-body vibration Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 – godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń) PN-EN 14253+A1:2011
21 Workplace environment- energy expenditure Air temperature
Range (5,0 - 35,0) °C Air flow Range (10,1 – 60,4) dm3/min
Direct measurement method Procedura Badawcza PB-01 wydanie 5 z dnia 28.02.2025 r.
22 Workplace environment- energy expenditure Energy expenditure (calculated) Procedura Badawcza PB-01 wydanie 5 z dnia 28.02.2025 r.
23 Workplace environment – ultrasonic noise Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz
Range (54-143) dB
Direct measurement method PN-Z-01339-2020-12
24 Workplace environment – ultrasonic noise Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do: (z obliczeń)
an 8-hour daily working time average weekly working time
PN-Z-01339-2020-12
25 Workplace environment – cold microclimate Air temperature
Range (-30 – 10) °C Black globe temperature Range (-30 – 10) °C Air humidity Range (20 – 90) % Air velocity Range (0,4 – 5,0) m/s
Direct measurement method PN-EN ISO 11079:2008
26 Workplace environment – cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008
27 Workplace environment – hot microclimate Air temperature
Range (10 – 50) °C Natural wet bulb temperature Range (10 – 50) °C Black globe temperature Range (10 – 50) °C
Direct measurement method PN-EN ISO 7243:2018-01
28 Workplace environment – hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01
29 Workplace environment – moderate microclimate Air temperature
Range (10 – 30) °C Black globe temperature Range (10 – 40) °C Air humidity Range (20 – 90) % Air velocity Range (0,15 – 1,0) m/s
Direct measurement method PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
30 Workplace environment – moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04
31 Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors Electric field strength:
in the frequency range from 10 Hz do 500 kHz Range 1 V/m – 50 kV/m in the frequency range from 0,2 MHz do 30 MHz Range (1-288) V/m in the frequency range from 800 MHz do 3 GHz Range (1-288) V/m
Regulated area: Metoda dostosowana do obszaru regulowanego
Direct measurement method PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025
32 Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors Magnetic flux density:
in the frequency range 0 Hz Range (0,1 – 1000) mT in the frequency range from 10 Hz do 500 kHz Range 50 nT – 19 mT
Regulated area: Metoda dostosowana do obszaru regulowanego
Direct measurement method PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025
33 Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors Magnetic field strength:
in the frequency range from 0,2 MHz do 30 MHz Range (0,01-16) A/m
Regulated area: Metoda dostosowana do obszaru regulowanego
Direct measurement method PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025
34 Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors Natężenie pola magnetycznego: w zakresie częstotliwości (z obliczeń)
0 Hz od 10 Hz – 500 kHz from 800 MHz do 3 GHz
Regulated area: Metoda dostosowana do obszaru regulowanego
PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025
35 Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors Electric field strength:
in the frequency range from 30 MHz do 800 MHz Range (1-288) V/m
Direct measurement method PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2
36 Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners Electric field strength:
in the frequency range from 10 Hz do 500 kHz Range 1 V/m – 50 kV/m in the frequency range from 0,2 MHz do 30 MHz Range (1-288) V/m in the frequency range from 800 MHz do 3 GHz Range (1-288) V/m
Regulated area: Metoda dostosowana do obszaru regulowanego
Direct measurement method PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025
37 Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners Magnetic flux density:
in the frequency range 0 Hz Range (0,1 – 1000) mT in the frequency range from 10 Hz do 500 kHz Range 50 nT – 19 mT
Regulated area: Metoda dostosowana do obszaru regulowanego
Direct measurement method PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025
38 Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners Magnetic field strength:
in the frequency range from 0,2 MHz do 30 MHz Range (0,01-16) A/m
Regulated area: Metoda dostosowana do obszaru regulowanego
Direct measurement method PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025
39 Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners Natężenie pola magnetycznego: w zakresie częstotliwości (z obliczeń)
0 Hz od 10 Hz – 500 kHz from 800 MHz do 3 GHz
Regulated area: Metoda dostosowana do obszaru regulowanego
PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025
40 Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners Electric field strength:
in the frequency range from 30 MHz do 800 MHz Range (1-288) V/m
Direct measurement method PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2
41 Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Electric field strength:
in the frequency range from 10 Hz do 500 kHz Range (1 – 50000) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
42 Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Magnetic flux density:
in the frequency range from 10 Hz do 500 kHz Range 50 nT – 19 mT
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
43 Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Natężenie pola magnetycznego: (z obliczeń)
in the frequency range from 10 Hz do 500 kHz
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
44 Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices Electric field strength:
in the frequency range from 10 Hz do 1 kHz Range (1 – 50000) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180
45 Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices Magnetic flux density:
in the frequency range from 10 Hz do 1 kHz Range 50 nT – 19 mT
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)
Direct measurement method Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180
46 Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices Natężenie pola magnetycznego: (z obliczeń)
in the frequency range from 10 Hz do 1 kHz
Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180

Reference standards (27)

Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025
Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025
PN-83/E-04040.03
PN-94/N-01307
PN-EN 14253+A1:2011
PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.
PN-EN ISO 11079:2008
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006
PN-EN ISO 7730:2006/Ap2:2016-04
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - pkt 10
PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2
PN-Z-01339-2020-12
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150
Procedura Badawcza PB-01 wydanie 5 z dnia 28.02.2025 r.
Procedura Badawcza PB-03 wydanie 6 z dnia 28.02.2025 r.
Procedura Badawcza PB-04 wydanie 11 z dnia 26.05.2026 r.
Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F