{"lab":{"_id":"69ad52a3de79e566650fb5ba","accr_number":"AB 1121","country":"PL","accr_body":"PCA","address":"Wojciech Kliś, Maciej Kliś, ZAKŁAD BADAŃ ŚRODOWISKA, ul. Wita Stwosza 11b, 43-300 Bielsko-Biała","categories":["environment"],"city":"Bielsko-Biała","imported_at":"2026-03-08T10:42:43.265Z","methods_count":46,"name":"PRO-INFO s.c.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1121.pdf"],"scope_summary":"","search_text":"pro-info s.c. wojciech kliś, maciej kliś, zakład badań środowiska, ul. wita stwosza 11b, 43-300 bielsko-biała environment materials other construction electronics pharma metrology","status":"active","updated_at":"2026-03-08T14:50:18.063Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T08:58:40.560Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pro-info.biz.pl/","parse_date":"2026-08-18T08:58:40.560Z","parse_source":"agent-claude-code","fields_of_testing":[{"codes":"C/33","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests and sampling - working environment (harmful factors - air)"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, hałas ultradźwiękowy, drgania, oświetlenie, pole elektromagnetyczne, mikroklimat, wydatek energetyczny)","en":"Tests concerning environmental engineering (environmental and climatic) – workplace (harmful and nuisance factors – noise, vibrations, lighting, electromagnetic field, microclimate, energy expenditure)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"},{"codes":"P/33","pl":"Pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Sampling - working environment (harmful factors - air)"}],"issue":{"no":"24","date":"07.08.2026"},"map_coord":[49.826853,19.026972],"map_geo":"nominatim-street","lab_locations":[{"name":"ZAKŁAD BADAŃ ŚRODOWISKA","address":"ul. Wita Stwosza 11b","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/18/f699f3bf52904aff90a31d1a8705d640/AB%201121.pdf","has_en":true,"category_counts":{"environment":46,"construction":2,"materials":1},"category_scores":{"environment":43.18,"construction":0.08,"materials":0.02},"has_zh":true},"methods":[{"_id":"6a841ec0af14b9c0e7b21487","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Pobieranie próbek powietrza w celu oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe – frakcja wdychalna – frakcja respirabilna"},{"name":"substancje organiczne, w tym – frakcja wdychalna"},{"name":"metale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna"},{"name":"azbest"},{"name":"włókna respirabilne"},{"name":"sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych"},{"name":"włókna respirabilne"},{"name":"respirabilne włókna ceramiczne"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek powietrza w celu oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nazbest\nwłókna respirabilne\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych\nwłókna respirabilne\nrespirabilne włókna ceramiczne\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Pobieranie próbek powietrza w celu oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nmetale i ich związki, w tym – frakcja wdychalna – frakcja respirabilna\nazbest\nwłókna respirabilne\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych\nwłókna respirabilne\nrespirabilne włókna ceramiczne\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Pobieranie probek powietrza w celu oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe – frakcja wdychalna – frakcja respirabilna\nsubstancje organiczne, w tym – frakcja wdychalna\nmetale i ich zwiazki, w tym – frakcja wdychalna – frakcja respirabilna\nazbest\nwlokna respirabilne\nsztuczne wlokna mineralne, z wyjatkiem ogniotrwalych wlokien ceramicznych\nwlokna respirabilne\nrespirabilne wlokna ceramiczne\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air sampling for occupational exposure assessment to:","parameters_en":[{"name":"dust agents – inhalable fraction – respirable fraction"},{"name":"organic substances, including – inhalable fraction"},{"name":"metals and their compounds, including – inhalable fraction – respirable fraction"},{"name":"asbestos"},{"name":"respirable fibres"},{"name":"man-made mineral fibres, excluding refractory ceramic fibres"},{"name":"respirable fibres"},{"name":"respirabilne włókna ceramiczne"}],"search_en":"Workplace environment − air Air sampling for occupational exposure assessment to: Personal dosimetry method dust agents – inhalable fraction – respirable fraction organic substances, including – inhalable fraction metals and their compounds, including – inhalable fraction – respirable fraction asbestos respirable fibres man-made mineral fibres, excluding refractory ceramic fibres respirable fibres PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment − air","search_zh":"工作环境 − 空气 个体剂量测定法 粉尘因素 — 可吸入组分 — 呼吸性组分 有机物质，包括 — 可吸入组分 金属及其化合物，包括 — 可吸入组分 — 呼吸性组分 石棉 呼吸性纤维 人造矿物纤维，耐火陶瓷纤维除外 呼吸性纤维 PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作环境 − 空气","parameters_zh":[{"name":"粉尘因素 — 可吸入组分 — 呼吸性组分"},{"name":"有机物质，包括 — 可吸入组分"},{"name":"金属及其化合物，包括 — 可吸入组分 — 呼吸性组分"},{"name":"石棉"},{"name":"呼吸性纤维"},{"name":"人造矿物纤维，耐火陶瓷纤维除外"},{"name":"呼吸性纤维"},{"name":"respirabilne włókna ceramiczne"}]},{"_id":"6a841ec0af14b9c0e7b21488","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment − air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 − 空气 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作环境 − 空气"},{"_id":"6a841ec0af14b9c0e7b21489","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Pobieranie próbek powietrza w celu oceny narażenia zawodowego na:","parameters":[{"name":"substancje nieorganiczne, w tym – frakcja wdychalna – frakcja torakalna – frakcja respirabilna"}],"technique":"Metoda stacjonarna; Metoda dozymetrii indywidualnej","techniques":["Metoda stacjonarna","Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek powietrza w celu oceny narażenia zawodowego na:\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja torakalna – frakcja respirabilna\nMetoda stacjonarna; Metoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Pobieranie próbek powietrza w celu oceny narażenia zawodowego na:\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja torakalna – frakcja respirabilna\nMetoda stacjonarna; Metoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Pobieranie probek powietrza w celu oceny narazenia zawodowego na:\nsubstancje nieorganiczne, w tym – frakcja wdychalna – frakcja torakalna – frakcja respirabilna\nMetoda stacjonarna; Metoda dozymetrii indywidualnej PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air sampling for occupational exposure assessment to:","parameters_en":[{"name":"inorganic substances, including – inhalable fraction – thoracic fraction – respirable fraction"}],"search_en":"Workplace environment − air Air sampling for occupational exposure assessment to: Stationary method; Personal dosimetry method inorganic substances, including – inhalable fraction – thoracic fraction – respirable fraction PN-Z-04008-7:2002+Az1:2004","technique_en":"Stationary method; Personal dosimetry method","test_object_en":"Workplace environment − air","search_zh":"工作环境 − 空气 定点法；个体剂量测定法 无机物质，其中包括 － 可吸入性粉尘 － 胸腔性粉尘 － 呼吸性粉尘 PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作环境 − 空气","parameters_zh":[{"name":"无机物质，其中包括 － 可吸入性粉尘 － 胸腔性粉尘 － 呼吸性粉尘"}],"technique_zh":"定点法；个体剂量测定法"},{"_id":"6a841ec0af14b9c0e7b2148a","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002+Az1:2004"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy − powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment − air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 − 空气 暴露指数（计算得出） PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作环境 − 空气"},{"_id":"6a841ec0af14b9c0e7b2148b","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Asfalt naftowy"},{"name":"Cement portlandzki"},{"name":"Ditlenek tytanu"},{"name":"Grafit naturalny"},{"name":"Grafit syntetyczny"},{"name":"Kaolin"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły drewna"},{"name":"Pyły mąki"},{"name":"Pyły niesklasyfikowane ze względu na toksyczność"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Siarczan (VI) wapnia (gips)"},{"name":"Sadza techniczna"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Węglan magnezu wapnia (dolomit)"},{"name":"Węglik krzemu, niewłóknisty"},{"name":"Zakres","range":"(0,07 – 17) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\nApatyty i fosforyty\nAsfalt naftowy\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,07 – 17) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\nApatyty i fosforyty\nAsfalt naftowy\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyły drewna\nPyły mąki\nPyły niesklasyfikowane ze względu na toksyczność\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWęgiel (kamienny, brunatny)\nWęglan magnezu wapnia (dolomit)\nWęglik krzemu, niewłóknisty\nZakres (0,07 – 17) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\nApatyty i fosforyty\nAsfalt naftowy\nCement portlandzki\nDitlenek tytanu\nGrafit naturalny\nGrafit syntetyczny\nKaolin\nKrzemionka bezpostaciowa i syntetyczna\nPyly drewna\nPyly maki\nPyly niesklasyfikowane ze wzgledu na toksycznosc\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nSiarczan (VI) wapnia (gips)\nSadza techniczna\nTalk\nWegiel (kamienny, brunatny)\nWeglan magnezu wapnia (dolomit)\nWeglik krzemu, niewloknisty\nZakres (0,07 – 17) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of harmful dust agents - inhalable fraction","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Petroleum bitumen"},{"name":"Portland cement"},{"name":"Titanium dioxide"},{"name":"Natural graphite"},{"name":"Synthetic graphite"},{"name":"Kaolin"},{"name":"Amorphous and synthetic silica"},{"name":"Wood dusts"},{"name":"Flour dusts"},{"name":"Dusts not classified according to toxicity"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Calcium sulfate (VI) (gypsum)"},{"name":"Carbon black"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Calcium magnesium carbonate (dolomite)"},{"name":"Silicon carbide, non-fibrous"},{"name":"Range","range":"(0,07 – 17) mg/m3"}],"search_en":"Workplace environment − air Concentration of harmful dust agents - inhalable fraction Gravimetric method Apatites and phosphorites Petroleum bitumen Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Calcium sulfate (VI) (gypsum) Carbon black Talc Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"石油沥青"},{"name":"硅酸盐水泥"},{"name":"二氧化钛"},{"name":"天然石墨"},{"name":"合成石墨"},{"name":"高岭土"},{"name":"无定形与合成二氧化硅"},{"name":"木粉尘"},{"name":"面粉粉尘"},{"name":"未按毒性分类的粉尘"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"硫酸钙（VI）（石膏）"},{"name":"炭黑"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"碳酸钙镁（白云石）"},{"name":"碳化硅，非纤维状"},{"name":"范围","range":"(0,07 – 17) mg/m3"}],"search_zh":"工作环境 − 空气 有害粉尘因素浓度 — 可吸入组分 重量法 磷灰石与磷块岩 石油沥青 硅酸盐水泥 二氧化钛 天然石墨 合成石墨 高岭土 无定形与合成二氧化硅 木粉尘 面粉粉尘 未按毒性分类的粉尘 动植物来源有机粉尘，木粉和面粉除外 硫酸钙（VI）（石膏） 炭黑 滑石 煤（烟煤、褐煤） 碳酸钙镁（白云石） 碳化硅，非纤维状 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a841ec0af14b9c0e7b2148c","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna","parameters":[{"name":"Apatyty i fosforyty"},{"name":"Cement portlandzki"},{"name":"Grafit naturalny"},{"name":"Krzemionka bezpostaciowa i syntetyczna"},{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Talk"},{"name":"Węgiel (kamienny, brunatny)"},{"name":"Zakres","range":"(0,07 - 17) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,07 - 17) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia- frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nTalk\nWęgiel (kamienny, brunatny)\nZakres (0,07 - 17) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia- frakcja respirabilna\nZakres:\nApatyty i fosforyty\nCement portlandzki\nGrafit naturalny\nKrzemionka bezpostaciowa i syntetyczna\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nTalk\nWegiel (kamienny, brunatny)\nZakres (0,07 - 17) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment","construction"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of dust agents harmful to health- respirable fraction","parameters_en":[{"name":"Apatites and phosphorites"},{"name":"Portland cement"},{"name":"Natural graphite"},{"name":"Amorphous and synthetic silica"},{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Talc"},{"name":"Coal (hard, brown)"},{"name":"Range","range":"(0,07 - 17) mg/m3"}],"search_en":"Workplace environment − air Concentration of dust agents harmful to health- respirable fraction Gravimetric method Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Talc Coal (hard, brown) Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"磷灰石与磷块岩"},{"name":"硅酸盐水泥"},{"name":"天然石墨"},{"name":"无定形与合成二氧化硅"},{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"滑石"},{"name":"煤（烟煤、褐煤）"},{"name":"范围","range":"(0,07 - 17) mg/m3"}],"search_zh":"工作环境 − 空气 有害健康的粉尘因子浓度 － 呼吸性粉尘 重量法 磷灰石与磷块岩 硅酸盐水泥 天然石墨 无定形与合成二氧化硅 动植物来源有机粉尘，木粉和面粉除外 滑石 煤（烟煤、褐煤） 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作环境 − 空气","methodology_zh":"有害健康的粉尘因子浓度 － 呼吸性粉尘"},{"_id":"6a841ec0af14b9c0e7b2148d","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres","range":"(2,3 – 272 mg/m3"},{"name":"Zakres","range":"(2,0 – 235) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 272 mg/m3\nZakres (2,0 – 235) ppm\nMetoda elektrochemiczna","reference":"Procedura Badawcza PB-04 wydanie 11 z dnia 26.05.2026 r.","norm_bases":["Procedura Badawcza PB-04 wydanie 11 z dnia 26.05.2026 r."],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − powietrze Stężenie tlenku węgla\nZakres:\nZakres (2,3 – 272 mg/m3\nZakres (2,0 – 235) ppm\nMetoda elektrochemiczna Procedura Badawcza PB-04 wydanie 11 z dnia 26.05.2026 r. Srodowisko pracy − powietrze Stezenie tlenku wegla\nZakres:\nZakres (2,3 – 272 mg/m3\nZakres (2,0 – 235) ppm\nMetoda elektrochemiczna Procedura Badawcza PB-04 wydanie 11 z dnia 26.05.2026 r.","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"Range","range":"(2,3 – 272 mg/m3"},{"name":"Range","range":"(2,0 – 235) ppm"}],"search_en":"Workplace environment − air Carbon monoxide concentration Electrochemical method Range Range Procedura Badawcza PB-04 wydanie 11 z dnia 26.05.2026 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment − air","parameters_zh":[{"name":"范围","range":"(2,3 – 272 mg/m3"},{"name":"范围","range":"(2,0 – 235) ppm"}],"search_zh":"工作环境 − 空气 一氧化碳浓度 电化学法 范围 范围 Procedura Badawcza PB-04 wydanie 11 z dnia 26.05.2026 r.","technique_zh":"电化学法","test_object_zh":"工作环境 − 空气","methodology_zh":"一氧化碳浓度"},{"_id":"6a841ec0af14b9c0e7b2148e","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(22-137) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(30-140) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (22-137) dB\nSzczytowy poziom dźwięku C\nZakres (30-140) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-94/N-01307 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - pkt 10","norm_bases":["PN-94/N-01307","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - pkt 10"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (22-137) dB\nSzczytowy poziom dźwięku C\nZakres (30-140) dB\nMetoda pomiarowa bezpośrednia PN-94/N-01307 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - pkt 10 Srodowisko pracy − halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (22-137) dB\nSzczytowy poziom dzwieku C\nZakres (30-140) dB\nMetoda pomiarowa bezposrednia PN-94/N-01307 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 - pkt 10","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(22-137) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(30-140) dB"}],"search_en":"Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-94/N-01307 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - pkt 10","technique_en":"Direct measurement method","test_object_en":"Workplace environment − noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(22-137) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(30-140) dB"}],"search_zh":"工作环境 − 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-94/N-01307 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - pkt 10","technique_zh":"直接测量法","test_object_zh":"工作环境 − 噪声"},{"_id":"6a841ec0af14b9c0e7b2148f","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − hałas","methodology":"Poziom ekspozycji na hałas odniesiony do: (z obliczeń)","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do: (z obliczeń)\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy","reference":"PN-94/N-01307 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - pkt 10","norm_bases":["PN-94/N-01307","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - pkt 10"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − hałas Poziom ekspozycji na hałas odniesiony do: (z obliczeń)\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy PN-94/N-01307 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - pkt 10 Srodowisko pracy − halas Poziom ekspozycji na halas odniesiony do: (z obliczen)\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy PN-94/N-01307 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 - pkt 10","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Noise exposure level normalised to: (calculated)","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"average weekly working time"}],"search_en":"Workplace environment − noise Noise exposure level normalised to: (calculated) an 8-hour daily working time average weekly working time PN-94/N-01307 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - pkt 10","test_object_en":"Workplace environment − noise","search_zh":"工作环境 − 噪声 8 小时日工作时间 PN-94/N-01307 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 - pkt 10","test_object_zh":"工作环境 − 噪声","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy"}]},{"_id":"6a841ec0af14b9c0e7b21490","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(5 – 9000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (5 – 9000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03 | Procedura Badawcza PB-03 wydanie 6 z dnia 28.02.2025 r.","norm_bases":["PN-83/E-04040.03","Procedura Badawcza PB-03 wydanie 6 z dnia 28.02.2025 r."],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5 – 9000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 | Procedura Badawcza PB-03 wydanie 6 z dnia 28.02.2025 r. Srodowisko pracy − oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5 – 9000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03 | Procedura Badawcza PB-03 wydanie 6 z dnia 28.02.2025 r.","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(5 – 9000) lx"}],"search_en":"Workplace environment − indoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03 | Procedura Badawcza PB-03 wydanie 6 z dnia 28.02.2025 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5 – 9000) lx"}],"search_zh":"工作场所环境 − 室内电气照明 照度 直接测量法 范围 PN-83/E-04040.03 | Procedura Badawcza PB-03 wydanie 6 z dnia 28.02.2025 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a841ec0af14b9c0e7b21491","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03 | Procedura Badawcza PB-03 wydanie 6 z dnia 28.02.2025 r.","norm_bases":["PN-83/E-04040.03","Procedura Badawcza PB-03 wydanie 6 z dnia 28.02.2025 r."],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 | Procedura Badawcza PB-03 wydanie 6 z dnia 28.02.2025 r. Srodowisko pracy − oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03 | Procedura Badawcza PB-03 wydanie 6 z dnia 28.02.2025 r.","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment − indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03 | Procedura Badawcza PB-03 wydanie 6 z dnia 28.02.2025 r.","test_object_en":"Workplace environment − indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 − 室内电气照明 照度均匀度（计算值） PN-83/E-04040.03 | Procedura Badawcza PB-03 wydanie 6 z dnia 28.02.2025 r.","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a841ec0af14b9c0e7b21492","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie awaryjne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 – 500) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5."],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie awaryjne Natężenie oświetlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezpośrednia PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5. Srodowisko pracy − oswietlenie awaryjne Natezenie oswietlenia\nZakres (0,5 – 500) lx\nMetoda pomiarowa bezposrednia PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 – 500) lx"}],"search_en":"Workplace environment − emergency lighting Illuminance Direct measurement method Range PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.","technique_en":"Direct measurement method","test_object_en":"Workplace environment − emergency lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 – 500) lx"}],"search_zh":"工作环境 － 应急照明 照度 直接测量法 范围 PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.","technique_zh":"直接测量法","test_object_zh":"工作环境 － 应急照明"},{"_id":"6a841ec0af14b9c0e7b21493","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie awaryjne","methodology":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5."],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie awaryjne Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5. Srodowisko pracy − oswietlenie awaryjne Stosunek minimalnego do maksymalnego natezenia oswietlenia (z obliczen) PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ratio of minimum to maximum illuminance (calculated)","search_en":"Workplace environment − emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.","test_object_en":"Workplace environment − emergency lighting","methodology_zh":"最小与最大照度之比（计算值）","search_zh":"工作环境 － 应急照明 最小与最大照度之比（计算值） PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.","test_object_zh":"工作环境 － 应急照明"},{"_id":"6a841ec0af14b9c0e7b21494","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie awaryjne","methodology":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5."],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − oświetlenie awaryjne Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5. Srodowisko pracy − oswietlenie awaryjne Rownomiernosc oswietlenia dla strefy wysokiego ryzyka (z obliczen) PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity for the high-risk zone (calculated)","search_en":"Workplace environment − emergency lighting Illuminance uniformity for the high-risk zone (calculated) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.","test_object_en":"Workplace environment − emergency lighting","methodology_zh":"高风险区照度均匀度（计算值）","search_zh":"工作环境 － 应急照明 高风险区照度均匀度（计算值） PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3-4.2.6; 4.3.3-4.3.6; 4.3.9; 4.4.3-4.4.6; 4.5; 5.","test_object_zh":"工作环境 － 应急照明"},{"_id":"6a841ec0af14b9c0e7b21495","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(22-136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (22-136) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (22-136) dB\nMetoda pomiarowa bezpośrednia Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (22-136) dB\nMetoda pomiarowa bezposrednia Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wylaczeniem pkt. F","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(22-136) dB"}],"search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F","technique_en":"Direct measurement method","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(22-136) dB"}],"search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F","technique_zh":"直接测量法","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a841ec0af14b9c0e7b21496","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F","norm_bases":["Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne − hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F Srodowisko ogolne − halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik Nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wylaczeniem pkt. F","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment − noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F","test_object_en":"General environment − noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 − 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik Nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (tj. Dz.U. 2023 poz. 1706) z wyłączeniem pkt. F","test_object_zh":"一般环境 − 来自装置、设备和工业企业的噪声"},{"_id":"6a841ec0af14b9c0e7b21497","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,3 – 100) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,3 – 100) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,3 – 100) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy − drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,3 – 100) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,3 – 100) m/s2"}],"search_en":"Workplace environment − hand-arm vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_en":"Direct measurement method","test_object_en":"Workplace environment − hand-arm vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,3 – 100) m/s2"}],"search_zh":"工作场所环境 − 手传振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 手传振动"},{"_id":"6a841ec0af14b9c0e7b21498","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 – godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)., Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 – godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)., Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004/A1:2015-11"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 – godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz)., Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11 Srodowisko pracy − drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8 – godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz)., Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Workplace environment − hand-arm vibration PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_en":"Workplace environment − hand-arm vibration","search_zh":"工作场所环境 − 手传振动 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004/A1:2015-11","test_object_zh":"工作场所环境 − 手传振动"},{"_id":"6a841ec0af14b9c0e7b21499","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,03 – 10) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 10) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 – 10) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy − drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,03 – 10) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,03 – 10) m/s2"}],"search_en":"Workplace environment − whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment − whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,03 – 10) m/s2"}],"search_zh":"工作场所环境 − 全身振动 频率计权振动加速度有效值 直接测量法 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","test_object_zh":"工作场所环境 − 全身振动"},{"_id":"6a841ec0af14b9c0e7b2149a","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 – godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 – godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8 – godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1,4awx, 1,4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy − drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8 – godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1,4awx, 1,4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Workplace environment − whole-body vibration PN-EN 14253+A1:2011","test_object_en":"Workplace environment − whole-body vibration","search_zh":"工作场所环境 − 全身振动 PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 − 全身振动"},{"_id":"6a841ec0af14b9c0e7b2149b","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy- wydatek energetyczny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(5,0 - 35,0) °C"},{"name":"Przepływ powietrza"},{"name":"Zakres","range":"(10,1 – 60,4) dm3/min"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (5,0 - 35,0) °C\nPrzepływ powietrza\nZakres (10,1 – 60,4) dm3/min\nMetoda pomiarowa bezpośrednia","reference":"Procedura Badawcza PB-01 wydanie 5 z dnia 28.02.2025 r.","norm_bases":["Procedura Badawcza PB-01 wydanie 5 z dnia 28.02.2025 r."],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy- wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (5,0 - 35,0) °C\nPrzepływ powietrza\nZakres (10,1 – 60,4) dm3/min\nMetoda pomiarowa bezpośrednia Procedura Badawcza PB-01 wydanie 5 z dnia 28.02.2025 r. Srodowisko pracy- wydatek energetyczny Temperatura powietrza\nZakres:\nZakres (5,0 - 35,0) °C\nPrzeplyw powietrza\nZakres (10,1 – 60,4) dm3/min\nMetoda pomiarowa bezposrednia Procedura Badawcza PB-01 wydanie 5 z dnia 28.02.2025 r.","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(5,0 - 35,0) °C"},{"name":"Air flow"},{"name":"Range","range":"(10,1 – 60,4) dm3/min"}],"search_en":"Workplace environment- energy expenditure Air temperature Direct measurement method Range Air flow Range Procedura Badawcza PB-01 wydanie 5 z dnia 28.02.2025 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment- energy expenditure","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(5,0 - 35,0) °C"},{"name":"空气流量"},{"name":"范围","range":"(10,1 – 60,4) dm3/min"}],"search_zh":"空气温度 直接测量法 范围 空气流量 范围 Procedura Badawcza PB-01 wydanie 5 z dnia 28.02.2025 r.","technique_zh":"直接测量法"},{"_id":"6a841ec0af14b9c0e7b2149c","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy- wydatek energetyczny","methodology":"Wydatek energetyczny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wydatek energetyczny (z obliczeń)","reference":"Procedura Badawcza PB-01 wydanie 5 z dnia 28.02.2025 r.","norm_bases":["Procedura Badawcza PB-01 wydanie 5 z dnia 28.02.2025 r."],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy- wydatek energetyczny Wydatek energetyczny (z obliczeń) Procedura Badawcza PB-01 wydanie 5 z dnia 28.02.2025 r. Srodowisko pracy- wydatek energetyczny Wydatek energetyczny (z obliczen) Procedura Badawcza PB-01 wydanie 5 z dnia 28.02.2025 r.","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Energy expenditure (calculated)","search_en":"Workplace environment- energy expenditure Energy expenditure (calculated) Procedura Badawcza PB-01 wydanie 5 z dnia 28.02.2025 r.","test_object_en":"Workplace environment- energy expenditure","methodology_zh":"能量消耗（计算值）","search_zh":"能量消耗（计算值） Procedura Badawcza PB-01 wydanie 5 z dnia 28.02.2025 r."},{"_id":"6a841ec0af14b9c0e7b2149d","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy","methodology":"Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz","parameters":[{"name":"Zakres","range":"(54-143) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres (54-143) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-Z-01339-2020-12","norm_bases":["PN-Z-01339-2020-12"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas ultradźwiękowy Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz Maksymalny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz\nZakres (54-143) dB\nMetoda pomiarowa bezpośrednia PN-Z-01339-2020-12 Srodowisko pracy – halas ultradzwiekowy Rownowazny poziom cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz Maksymalny poziom cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz\nZakres (54-143) dB\nMetoda pomiarowa bezposrednia PN-Z-01339-2020-12","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz","parameters_en":[{"name":"Range","range":"(54-143) dB"}],"search_en":"Workplace environment – ultrasonic noise Equivalent sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Maximum sound pressure level in one-third octave bands with centre frequencies from 10 kHz to 40 kHz Direct measurement method Range PN-Z-01339-2020-12","technique_en":"Direct measurement method","test_object_en":"Workplace environment – ultrasonic noise","parameters_zh":[{"name":"范围","range":"(54-143) dB"}],"search_zh":"工作场所环境 — 超声噪声 中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级 中心频率自 10 kHz 至 40 kHz 的1/3倍频程最大声压级 直接测量法 范围 PN-Z-01339-2020-12","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 超声噪声","methodology_zh":"中心频率自 10 kHz 至 40 kHz 的1/3倍频程等效声压级 中心频率自 10 kHz 至 40 kHz 的1/3倍频程最大声压级"},{"_id":"6a841ec0af14b9c0e7b2149e","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy – hałas ultradźwiękowy","methodology":"Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do: (z obliczeń)","parameters":[{"name":"8 - godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy"}],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do: (z obliczeń)\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy","reference":"PN-Z-01339-2020-12","norm_bases":["PN-Z-01339-2020-12"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas ultradźwiękowy Równoważny poziom ciśnienia akustycznego w pasmach tercjowych o częstotliwościach środkowych od 10 kHz do 40 kHz odniesione do: (z obliczeń)\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy PN-Z-01339-2020-12 Srodowisko pracy – halas ultradzwiekowy Rownowazny poziom cisnienia akustycznego w pasmach tercjowych o czestotliwosciach srodkowych od 10 kHz do 40 kHz odniesione do: (z obliczen)\nZakres:\n8 - godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy PN-Z-01339-2020-12","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"average weekly working time"}],"search_en":"Workplace environment – ultrasonic noise an 8-hour daily working time average weekly working time PN-Z-01339-2020-12","test_object_en":"Workplace environment – ultrasonic noise","search_zh":"工作场所环境 — 超声噪声 每日 8 小时工作时间 PN-Z-01339-2020-12","test_object_zh":"工作场所环境 — 超声噪声","parameters_zh":[{"name":"每日 8 小时工作时间"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy"}]},{"_id":"6a841ec0af14b9c0e7b2149f","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-30 – 10) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30 – 10) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,4 – 5,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 10) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,4 – 5,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 10) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,4 – 5,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy – mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30 – 10) °C\nTemperatura poczernionej kuli\nZakres (-30 – 10) °C\nWilgotnosc powietrza\nZakres (20 – 90) %\nPredkosc powietrza\nZakres (0,4 – 5,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-30 – 10) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-30 – 10) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20 – 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,4 – 5,0) m/s"}],"search_en":"Workplace environment – cold microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment – cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30 – 10) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-30 – 10) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,4 – 5,0) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a841ec0af14b9c0e7b214a0","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy – mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"IREQmin index, IREQneutral index, twc index (calculated)","search_en":"Workplace environment – cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008","test_object_en":"Workplace environment – cold microclimate","search_zh":"工作场所环境 — 低温微气候 IREQmin 指数、IREQneutral 指数、twc 指数（计算值） PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候","methodology_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值）"},{"_id":"6a841ec0af14b9c0e7b214a1","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 – 50) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(10 – 50) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 50) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura wilgotna naturalna\nZakres (10 – 50) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura wilgotna naturalna\nZakres (10 – 50) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (10 – 50) °C\nTemperatura wilgotna naturalna\nZakres (10 – 50) °C\nTemperatura poczernionej kuli\nZakres (10 – 50) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 – 50) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(10 – 50) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 50) °C"}],"search_en":"Workplace environment – hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","technique_en":"Direct measurement method","test_object_en":"Workplace environment – hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 50) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(10 – 50) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 50) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a841ec0af14b9c0e7b214a2","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy – mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment – hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01","test_object_en":"Workplace environment – hot microclimate","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a841ec0af14b9c0e7b214a3","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(10 – 30) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10 – 40) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20 – 90) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 – 1,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nWilgotność powietrza\nZakres (20 – 90) %\nPrędkość powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy – mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (10 – 30) °C\nTemperatura poczernionej kuli\nZakres (10 – 40) °C\nWilgotnosc powietrza\nZakres (20 – 90) %\nPredkosc powietrza\nZakres (0,15 – 1,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(10 – 30) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10 – 40) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20 – 90) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 – 1,0) m/s"}],"search_en":"Workplace environment – moderate microclimate Air temperature Direct measurement method Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment – moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10 – 30) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10 – 40) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20 – 90) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 – 1,0) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a841ec0af14b9c0e7b214a4","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy – mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006","PN-EN ISO 7730:2006/Ap2:2016-04"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04 Srodowisko pracy – mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment – moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_en":"Workplace environment – moderate microclimate","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） PN-EN ISO 7730:2006 | PN-EN ISO 7730:2006/Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a841ec0af14b9c0e7b214a5","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: -urządzenia do spawania łukowego -zgrzewarki rezystancyjne -przemysłowe magnetyzery i demagnetyzatory -urządzenia do grzania indukcyjnego -przemysłowe piece, nagrzewnice i suszarki mikrofalowe, -urządzenia do wytwarzania i przetwarzania tworzyw sztucznych -urządzenia do lutowania -elektrodrążarki -piece oporowe i łukowe -generatory i silniki elektryczne","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 500 kHz"},{"name":"Zakres","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości od 0,2 MHz","range":"do 30 MHz"},{"name":"Zakres","range":"(1-288) V/m"},{"name":"w zakresie częstotliwości od 800 MHz","range":"do 3 GHz"},{"name":"Zakres","range":"(1-288) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 500 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 0,2 MHz do 30 MHz\nZakres (1-288) V/m\nw zakresie częstotliwości od 800 MHz do 3 GHz\nZakres (1-288) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025","norm_bases":["PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2","Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":"Metoda dostosowana do obszaru regulowanego","flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: -urządzenia do spawania łukowego -zgrzewarki rezystancyjne -przemysłowe magnetyzery i demagnetyzatory -urządzenia do grzania indukcyjnego -przemysłowe piece, nagrzewnice i suszarki mikrofalowe, -urządzenia do wytwarzania i przetwarzania tworzyw sztucznych -urządzenia do lutowania -elektrodrążarki -piece oporowe i łukowe -generatory i silniki elektryczne Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 500 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 0,2 MHz do 30 MHz\nZakres (1-288) V/m\nw zakresie częstotliwości od 800 MHz do 3 GHz\nZakres (1-288) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025 Srodowisko pracy − pole elektromagnetyczne od instalacji i urzadzen przemyslowych: -urzadzenia do spawania lukowego -zgrzewarki rezystancyjne -przemyslowe magnetyzery i demagnetyzatory -urzadzenia do grzania indukcyjnego -przemyslowe piece, nagrzewnice i suszarki mikrofalowe, -urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych -urzadzenia do lutowania -elektrodrazarki -piece oporowe i lukowe -generatory i silniki elektryczne Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 500 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie czestotliwosci od 0,2 MHz do 30 MHz\nZakres (1-288) V/m\nw zakresie czestotliwosci od 800 MHz do 3 GHz\nZakres (1-288) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 z wylaczeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 500 kHz"},{"name":"Range","range":"1 V/m – 50 kV/m"},{"name":"in the frequency range from 0,2 MHz","range":"do 30 MHz"},{"name":"Range","range":"(1-288) V/m"},{"name":"in the frequency range from 800 MHz","range":"do 3 GHz"},{"name":"Range","range":"(1-288) V/m"}],"search_en":"Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors Electric field strength: Direct measurement method in the frequency range from 10 Hz Range in the frequency range from 0,2 MHz Range in the frequency range from 800 MHz Range PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 500 kHz"},{"name":"范围","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości od 0,2 MHz","range":"do 30 MHz"},{"name":"范围","range":"(1-288) V/m"},{"name":"频率范围自 800 MHz 起","range":"do 3 GHz"},{"name":"范围","range":"(1-288) V/m"}],"search_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 感应加热设备 － 工业微波炉、加热器与干燥器 － 塑料制造与加工设备 － 钎焊设备 － 电火花加工机 电场强度： 直接测量法 频率范围自 10 Hz 起 范围 范围 频率范围自 800 MHz 起 范围 PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025","technique_zh":"直接测量法","test_object_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 感应加热设备 － 工业微波炉、加热器与干燥器 － 塑料制造与加工设备 － 钎焊设备 － 电火花加工机"},{"_id":"6a841ec0af14b9c0e7b214a6","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: -urządzenia do spawania łukowego -zgrzewarki rezystancyjne -przemysłowe magnetyzery i demagnetyzatory -urządzenia do grzania indukcyjnego -przemysłowe piece, nagrzewnice i suszarki mikrofalowe, -urządzenia do wytwarzania i przetwarzania tworzyw sztucznych -urządzenia do lutowania -elektrodrążarki -piece oporowe i łukowe -generatory i silniki elektryczne","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości 0 Hz"},{"name":"Zakres","range":"(0,1 – 1000) mT"},{"name":"w zakresie częstotliwości od 10 Hz","range":"do 500 kHz"},{"name":"Zakres","range":"50 nT – 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 0 Hz\nZakres (0,1 – 1000) mT\nw zakresie częstotliwości od 10 Hz do 500 kHz\nZakres 50 nT – 19 mT\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025","norm_bases":["PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2","Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":"Metoda dostosowana do obszaru regulowanego","flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: -urządzenia do spawania łukowego -zgrzewarki rezystancyjne -przemysłowe magnetyzery i demagnetyzatory -urządzenia do grzania indukcyjnego -przemysłowe piece, nagrzewnice i suszarki mikrofalowe, -urządzenia do wytwarzania i przetwarzania tworzyw sztucznych -urządzenia do lutowania -elektrodrążarki -piece oporowe i łukowe -generatory i silniki elektryczne Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 0 Hz\nZakres (0,1 – 1000) mT\nw zakresie częstotliwości od 10 Hz do 500 kHz\nZakres 50 nT – 19 mT\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025 Srodowisko pracy − pole elektromagnetyczne od instalacji i urzadzen przemyslowych: -urzadzenia do spawania lukowego -zgrzewarki rezystancyjne -przemyslowe magnetyzery i demagnetyzatory -urzadzenia do grzania indukcyjnego -przemyslowe piece, nagrzewnice i suszarki mikrofalowe, -urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych -urzadzenia do lutowania -elektrodrazarki -piece oporowe i lukowe -generatory i silniki elektryczne Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci 0 Hz\nZakres (0,1 – 1000) mT\nw zakresie czestotliwosci od 10 Hz do 500 kHz\nZakres 50 nT – 19 mT\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 z wylaczeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range 0 Hz"},{"name":"Range","range":"(0,1 – 1000) mT"},{"name":"in the frequency range from 10 Hz","range":"do 500 kHz"},{"name":"Range","range":"50 nT – 19 mT"}],"search_en":"Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors Magnetic flux density: Direct measurement method in the frequency range 0 Hz Range in the frequency range from 10 Hz Range PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors","parameters_zh":[{"name":"频率范围 0 Hz"},{"name":"范围","range":"(0,1 – 1000) mT"},{"name":"频率范围自 10 Hz 起","range":"do 500 kHz"},{"name":"范围","range":"50 nT – 19 mT"}],"search_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 感应加热设备 － 工业微波炉、加热器与干燥器 － 塑料制造与加工设备 － 钎焊设备 － 电火花加工机 磁感应强度： 直接测量法 频率范围 0 Hz 范围 频率范围自 10 Hz 起 范围 PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025","technique_zh":"直接测量法","methodology_zh":"磁感应强度：","test_object_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 感应加热设备 － 工业微波炉、加热器与干燥器 － 塑料制造与加工设备 － 钎焊设备 － 电火花加工机"},{"_id":"6a841ec0af14b9c0e7b214a7","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: -urządzenia do spawania łukowego -zgrzewarki rezystancyjne -przemysłowe magnetyzery i demagnetyzatory -urządzenia do grzania indukcyjnego -przemysłowe piece, nagrzewnice i suszarki mikrofalowe, -urządzenia do wytwarzania i przetwarzania tworzyw sztucznych -urządzenia do lutowania -elektrodrążarki -piece oporowe i łukowe -generatory i silniki elektryczne","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 0,2 MHz","range":"do 30 MHz"},{"name":"Zakres","range":"(0,01-16) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,2 MHz do 30 MHz\nZakres (0,01-16) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025","norm_bases":["PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2","Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":"Metoda dostosowana do obszaru regulowanego","flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: -urządzenia do spawania łukowego -zgrzewarki rezystancyjne -przemysłowe magnetyzery i demagnetyzatory -urządzenia do grzania indukcyjnego -przemysłowe piece, nagrzewnice i suszarki mikrofalowe, -urządzenia do wytwarzania i przetwarzania tworzyw sztucznych -urządzenia do lutowania -elektrodrążarki -piece oporowe i łukowe -generatory i silniki elektryczne Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,2 MHz do 30 MHz\nZakres (0,01-16) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025 Srodowisko pracy − pole elektromagnetyczne od instalacji i urzadzen przemyslowych: -urzadzenia do spawania lukowego -zgrzewarki rezystancyjne -przemyslowe magnetyzery i demagnetyzatory -urzadzenia do grzania indukcyjnego -przemyslowe piece, nagrzewnice i suszarki mikrofalowe, -urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych -urzadzenia do lutowania -elektrodrazarki -piece oporowe i lukowe -generatory i silniki elektryczne Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0,2 MHz do 30 MHz\nZakres (0,01-16) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 z wylaczeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 0,2 MHz","range":"do 30 MHz"},{"name":"Range","range":"(0,01-16) A/m"}],"search_en":"Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors Magnetic field strength: Direct measurement method in the frequency range from 0,2 MHz Range PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors","methodology_zh":"磁场强度：","parameters_zh":[{"name":"w zakresie częstotliwości od 0,2 MHz","range":"do 30 MHz"},{"name":"范围","range":"(0,01-16) A/m"}],"search_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 感应加热设备 － 工业微波炉、加热器与干燥器 － 塑料制造与加工设备 － 钎焊设备 － 电火花加工机 磁场强度： 直接测量法 范围 PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025","technique_zh":"直接测量法","test_object_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 感应加热设备 － 工业微波炉、加热器与干燥器 － 塑料制造与加工设备 － 钎焊设备 － 电火花加工机"},{"_id":"6a841ec0af14b9c0e7b214a8","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: -urządzenia do spawania łukowego -zgrzewarki rezystancyjne -przemysłowe magnetyzery i demagnetyzatory -urządzenia do grzania indukcyjnego -przemysłowe piece, nagrzewnice i suszarki mikrofalowe, -urządzenia do wytwarzania i przetwarzania tworzyw sztucznych -urządzenia do lutowania -elektrodrążarki -piece oporowe i łukowe -generatory i silniki elektryczne","methodology":"Natężenie pola magnetycznego: w zakresie częstotliwości (z obliczeń)","parameters":[{"name":"0 Hz"},{"name":"od 10 Hz – 500 kHz"},{"name":"od 800 MHz","range":"do 3 GHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego: w zakresie częstotliwości (z obliczeń)\nZakres:\n0 Hz\nod 10 Hz – 500 kHz\nod 800 MHz do 3 GHz","reference":"PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025","norm_bases":["PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2","Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":"Metoda dostosowana do obszaru regulowanego","flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: -urządzenia do spawania łukowego -zgrzewarki rezystancyjne -przemysłowe magnetyzery i demagnetyzatory -urządzenia do grzania indukcyjnego -przemysłowe piece, nagrzewnice i suszarki mikrofalowe, -urządzenia do wytwarzania i przetwarzania tworzyw sztucznych -urządzenia do lutowania -elektrodrążarki -piece oporowe i łukowe -generatory i silniki elektryczne Natężenie pola magnetycznego: w zakresie częstotliwości (z obliczeń)\nZakres:\n0 Hz\nod 10 Hz – 500 kHz\nod 800 MHz do 3 GHz PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025 Srodowisko pracy − pole elektromagnetyczne od instalacji i urzadzen przemyslowych: -urzadzenia do spawania lukowego -zgrzewarki rezystancyjne -przemyslowe magnetyzery i demagnetyzatory -urzadzenia do grzania indukcyjnego -przemyslowe piece, nagrzewnice i suszarki mikrofalowe, -urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych -urzadzenia do lutowania -elektrodrazarki -piece oporowe i lukowe -generatory i silniki elektryczne Natezenie pola magnetycznego: w zakresie czestotliwosci (z obliczen)\nZakres:\n0 Hz\nod 10 Hz – 500 kHz\nod 800 MHz do 3 GHz PN-T-06580-3:2002 z wylaczeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"0 Hz"},{"name":"od 10 Hz – 500 kHz"},{"name":"from 800 MHz","range":"do 3 GHz"}],"search_en":"Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors 0 Hz from 800 MHz PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025","test_object_en":"Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors","search_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 感应加热设备 － 工业微波炉、加热器与干燥器 － 塑料制造与加工设备 － 钎焊设备 － 电火花加工机 PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-65 wydanie 1 z dnia 12.06.2025","test_object_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 感应加热设备 － 工业微波炉、加热器与干燥器 － 塑料制造与加工设备 － 钎焊设备 － 电火花加工机"},{"_id":"6a841ec0af14b9c0e7b214a9","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: -urządzenia do spawania łukowego -zgrzewarki rezystancyjne -przemysłowe magnetyzery i demagnetyzatory -urządzenia do grzania indukcyjnego -przemysłowe piece, nagrzewnice i suszarki mikrofalowe, -urządzenia do wytwarzania i przetwarzania tworzyw sztucznych -urządzenia do lutowania -elektrodrążarki -piece oporowe i łukowe -generatory i silniki elektryczne","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 30 MHz","range":"do 800 MHz"},{"name":"Zakres","range":"(1-288) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 30 MHz do 800 MHz\nZakres (1-288) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2","norm_bases":["PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy − pole elektromagnetyczne od instalacji i urządzeń przemysłowych: -urządzenia do spawania łukowego -zgrzewarki rezystancyjne -przemysłowe magnetyzery i demagnetyzatory -urządzenia do grzania indukcyjnego -przemysłowe piece, nagrzewnice i suszarki mikrofalowe, -urządzenia do wytwarzania i przetwarzania tworzyw sztucznych -urządzenia do lutowania -elektrodrążarki -piece oporowe i łukowe -generatory i silniki elektryczne Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 30 MHz do 800 MHz\nZakres (1-288) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 Srodowisko pracy − pole elektromagnetyczne od instalacji i urzadzen przemyslowych: -urzadzenia do spawania lukowego -zgrzewarki rezystancyjne -przemyslowe magnetyzery i demagnetyzatory -urzadzenia do grzania indukcyjnego -przemyslowe piece, nagrzewnice i suszarki mikrofalowe, -urzadzenia do wytwarzania i przetwarzania tworzyw sztucznych -urzadzenia do lutowania -elektrodrazarki -piece oporowe i lukowe -generatory i silniki elektryczne Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 30 MHz do 800 MHz\nZakres (1-288) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 z wylaczeniem pkt. 2.1.4.2","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range from 30 MHz","range":"do 800 MHz"},{"name":"Range","range":"(1-288) V/m"}],"search_en":"Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors Electric field strength: Direct measurement method in the frequency range from 30 MHz Range PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2","technique_en":"Direct measurement method","test_object_en":"Workplace environment − electromagnetic field from industrial installations and equipment: -arc welding equipment -resistance welding machines -industrial magnetisers and demagnetisers -induction heating equipment -industrial microwave furnaces, heaters and dryers, -equipment for the production and processing of plastics -soldering equipment -electrical discharge machines -resistance and arc furnaces -electric generators and motors","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 30 MHz 起","range":"do 800 MHz"},{"name":"范围","range":"(1-288) V/m"}],"search_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 感应加热设备 － 工业微波炉、加热器与干燥器 － 塑料制造与加工设备 － 钎焊设备 － 电火花加工机 电场强度： 直接测量法 频率范围自 30 MHz 起 范围 PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2","technique_zh":"直接测量法","test_object_zh":"工作环境 － 来自工业装置与设备的电磁场：－ 弧焊设备 － 电阻焊机 － 工业充磁与退磁装置 － 感应加热设备 － 工业微波炉、加热器与干燥器 － 塑料制造与加工设备 － 钎焊设备 － 电火花加工机"},{"_id":"6a841ec0af14b9c0e7b214aa","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne -diatermie fizykoterapeutyczne -skanery rezonansu magnetycznego","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 500 kHz"},{"name":"Zakres","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości od 0,2 MHz","range":"do 30 MHz"},{"name":"Zakres","range":"(1-288) V/m"},{"name":"w zakresie częstotliwości od 800 MHz","range":"do 3 GHz"},{"name":"Zakres","range":"(1-288) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 500 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 0,2 MHz do 30 MHz\nZakres (1-288) V/m\nw zakresie częstotliwości od 800 MHz do 3 GHz\nZakres (1-288) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025","norm_bases":["PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2","Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":"Metoda dostosowana do obszaru regulowanego","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne -diatermie fizykoterapeutyczne -skanery rezonansu magnetycznego Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 500 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie częstotliwości od 0,2 MHz do 30 MHz\nZakres (1-288) V/m\nw zakresie częstotliwości od 800 MHz do 3 GHz\nZakres (1-288) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025 Srodowisko pracy - pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne -diatermie fizykoterapeutyczne -skanery rezonansu magnetycznego Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 500 kHz\nZakres 1 V/m – 50 kV/m\nw zakresie czestotliwosci od 0,2 MHz do 30 MHz\nZakres (1-288) V/m\nw zakresie czestotliwosci od 800 MHz do 3 GHz\nZakres (1-288) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 z wylaczeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 500 kHz"},{"name":"Range","range":"1 V/m – 50 kV/m"},{"name":"in the frequency range from 0,2 MHz","range":"do 30 MHz"},{"name":"Range","range":"(1-288) V/m"},{"name":"in the frequency range from 800 MHz","range":"do 3 GHz"},{"name":"Range","range":"(1-288) V/m"}],"search_en":"Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners Electric field strength: Direct measurement method in the frequency range from 10 Hz Range in the frequency range from 0,2 MHz Range in the frequency range from 800 MHz Range PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 500 kHz"},{"name":"范围","range":"1 V/m – 50 kV/m"},{"name":"w zakresie częstotliwości od 0,2 MHz","range":"do 30 MHz"},{"name":"范围","range":"(1-288) V/m"},{"name":"频率范围自 800 MHz 起","range":"do 3 GHz"},{"name":"范围","range":"(1-288) V/m"}],"search_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪 电场强度： 直接测量法 频率范围自 10 Hz 起 范围 范围 频率范围自 800 MHz 起 范围 PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025","technique_zh":"直接测量法","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪"},{"_id":"6a841ec0af14b9c0e7b214ab","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne -diatermie fizykoterapeutyczne -skanery rezonansu magnetycznego","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości 0 Hz"},{"name":"Zakres","range":"(0,1 – 1000) mT"},{"name":"w zakresie częstotliwości od 10 Hz","range":"do 500 kHz"},{"name":"Zakres","range":"50 nT – 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 0 Hz\nZakres (0,1 – 1000) mT\nw zakresie częstotliwości od 10 Hz do 500 kHz\nZakres 50 nT – 19 mT\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025","norm_bases":["PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2","Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":"Metoda dostosowana do obszaru regulowanego","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne -diatermie fizykoterapeutyczne -skanery rezonansu magnetycznego Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 0 Hz\nZakres (0,1 – 1000) mT\nw zakresie częstotliwości od 10 Hz do 500 kHz\nZakres 50 nT – 19 mT\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025 Srodowisko pracy - pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne -diatermie fizykoterapeutyczne -skanery rezonansu magnetycznego Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci 0 Hz\nZakres (0,1 – 1000) mT\nw zakresie czestotliwosci od 10 Hz do 500 kHz\nZakres 50 nT – 19 mT\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 z wylaczeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range 0 Hz"},{"name":"Range","range":"(0,1 – 1000) mT"},{"name":"in the frequency range from 10 Hz","range":"do 500 kHz"},{"name":"Range","range":"50 nT – 19 mT"}],"search_en":"Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners Magnetic flux density: Direct measurement method in the frequency range 0 Hz Range in the frequency range from 10 Hz Range PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners","parameters_zh":[{"name":"频率范围 0 Hz"},{"name":"范围","range":"(0,1 – 1000) mT"},{"name":"频率范围自 10 Hz 起","range":"do 500 kHz"},{"name":"范围","range":"50 nT – 19 mT"}],"search_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪 磁感应强度： 直接测量法 频率范围 0 Hz 范围 频率范围自 10 Hz 起 范围 PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025","technique_zh":"直接测量法","methodology_zh":"磁感应强度：","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪"},{"_id":"6a841ec0af14b9c0e7b214ac","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne -diatermie fizykoterapeutyczne -skanery rezonansu magnetycznego","methodology":"Natężenie pola magnetycznego:","parameters":[{"name":"w zakresie częstotliwości od 0,2 MHz","range":"do 30 MHz"},{"name":"Zakres","range":"(0,01-16) A/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,2 MHz do 30 MHz\nZakres (0,01-16) A/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025","norm_bases":["PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2","Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":"Metoda dostosowana do obszaru regulowanego","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne -diatermie fizykoterapeutyczne -skanery rezonansu magnetycznego Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości od 0,2 MHz do 30 MHz\nZakres (0,01-16) A/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025 Srodowisko pracy - pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne -diatermie fizykoterapeutyczne -skanery rezonansu magnetycznego Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci od 0,2 MHz do 30 MHz\nZakres (0,01-16) A/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 z wylaczeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength:","parameters_en":[{"name":"in the frequency range from 0,2 MHz","range":"do 30 MHz"},{"name":"Range","range":"(0,01-16) A/m"}],"search_en":"Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners Magnetic field strength: Direct measurement method in the frequency range from 0,2 MHz Range PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners","methodology_zh":"磁场强度：","parameters_zh":[{"name":"w zakresie częstotliwości od 0,2 MHz","range":"do 30 MHz"},{"name":"范围","range":"(0,01-16) A/m"}],"search_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪 磁场强度： 直接测量法 范围 PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025","technique_zh":"直接测量法","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪"},{"_id":"6a841ec0af14b9c0e7b214ad","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne -diatermie fizykoterapeutyczne -skanery rezonansu magnetycznego","methodology":"Natężenie pola magnetycznego: w zakresie częstotliwości (z obliczeń)","parameters":[{"name":"0 Hz"},{"name":"od 10 Hz – 500 kHz"},{"name":"od 800 MHz","range":"do 3 GHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego: w zakresie częstotliwości (z obliczeń)\nZakres:\n0 Hz\nod 10 Hz – 500 kHz\nod 800 MHz do 3 GHz","reference":"PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025","norm_bases":["PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2","Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":"Metoda dostosowana do obszaru regulowanego","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne -diatermie fizykoterapeutyczne -skanery rezonansu magnetycznego Natężenie pola magnetycznego: w zakresie częstotliwości (z obliczeń)\nZakres:\n0 Hz\nod 10 Hz – 500 kHz\nod 800 MHz do 3 GHz PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025 Srodowisko pracy - pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne -diatermie fizykoterapeutyczne -skanery rezonansu magnetycznego Natezenie pola magnetycznego: w zakresie czestotliwosci (z obliczen)\nZakres:\n0 Hz\nod 10 Hz – 500 kHz\nod 800 MHz do 3 GHz PN-T-06580-3:2002 z wylaczeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"0 Hz"},{"name":"od 10 Hz – 500 kHz"},{"name":"from 800 MHz","range":"do 3 GHz"}],"search_en":"Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners 0 Hz from 800 MHz PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025","test_object_en":"Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners","search_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪 PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 | Instrukcja robocza nr IR-66 wydanie 1 z dnia 12.06.2025","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪"},{"_id":"6a841ec0af14b9c0e7b214ae","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne -diatermie fizykoterapeutyczne -skanery rezonansu magnetycznego","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 30 MHz","range":"do 800 MHz"},{"name":"Zakres","range":"(1-288) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 30 MHz do 800 MHz\nZakres (1-288) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2","norm_bases":["PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne pochodzące od urządzeń stosowanych w technice medycznej: - diatermie chirurgiczne -diatermie fizykoterapeutyczne -skanery rezonansu magnetycznego Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 30 MHz do 800 MHz\nZakres (1-288) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2 Srodowisko pracy - pole elektromagnetyczne pochodzace od urzadzen stosowanych w technice medycznej: - diatermie chirurgiczne -diatermie fizykoterapeutyczne -skanery rezonansu magnetycznego Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 30 MHz do 800 MHz\nZakres (1-288) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 z wylaczeniem pkt. 2.1.4.2","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range from 30 MHz","range":"do 800 MHz"},{"name":"Range","range":"(1-288) V/m"}],"search_en":"Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners Electric field strength: Direct measurement method in the frequency range from 30 MHz Range PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field from equipment used in medical technology: - surgical diathermy -physiotherapeutic diathermy -magnetic resonance scanners","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 30 MHz 起","range":"do 800 MHz"},{"name":"范围","range":"(1-288) V/m"}],"search_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪 电场强度： 直接测量法 频率范围自 30 MHz 起 范围 PN-T-06580-3:2002 z wyłączeniem pkt. 2.1.4.2","technique_zh":"直接测量法","test_object_zh":"工作环境 － 医疗技术设备产生的电磁场：－ 外科电刀 － 理疗透热治疗仪 － 磁共振扫描仪"},{"_id":"6a841ec0af14b9c0e7b214af","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 500 kHz"},{"name":"Zakres","range":"(1 – 50000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 500 kHz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 500 kHz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 500 kHz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91 – 150","categories":["environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 500 kHz"},{"name":"Range","range":"(1 – 50000) V/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Electric field strength: Direct measurement method in the frequency range from 10 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 500 kHz"},{"name":"范围","range":"(1 – 50000) V/m"}],"search_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场 电场强度： 直接测量法 频率范围自 10 Hz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场"},{"_id":"6a841ec0af14b9c0e7b214b0","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 500 kHz"},{"name":"Zakres","range":"50 nT – 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 10 Hz do 500 kHz\nZakres 50 nT – 19 mT\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 10 Hz do 500 kHz\nZakres 50 nT – 19 mT\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 500 kHz\nZakres 50 nT – 19 mT\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91 – 150","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 500 kHz"},{"name":"Range","range":"50 nT – 19 mT"}],"search_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry Magnetic flux density: Direct measurement method in the frequency range from 10 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 500 kHz"},{"name":"范围","range":"50 nT – 19 mT"}],"search_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场 磁感应强度： 直接测量法 频率范围自 10 Hz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","technique_zh":"直接测量法","methodology_zh":"磁感应强度：","test_object_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场"},{"_id":"6a841ec0af14b9c0e7b214b1","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","methodology":"Natężenie pola magnetycznego: (z obliczeń)","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 500 kHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego: (z obliczeń)\nw zakresie częstotliwości od 10 Hz do 500 kHz","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola magnetycznego: (z obliczeń)\nw zakresie częstotliwości od 10 Hz do 500 kHz Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola magnetycznego: (z obliczen)\nw zakresie czestotliwosci od 10 Hz do 500 kHz Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91 – 150","categories":["environment"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 500 kHz"}],"search_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry in the frequency range from 10 Hz Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","test_object_en":"Workplace environment - electromagnetic field in the workspace during the use of power systems and AC electrical supply installations in the power industry","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 500 kHz"}],"search_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场 频率范围自 10 Hz 起 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91 – 150","test_object_zh":"工作场所环境 — 使用电力系统与电力行业交流供电装置期间工作空间内的电磁场"},{"_id":"6a841ec0af14b9c0e7b214b2","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń do magnetoterapii","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 1 kHz"},{"name":"Zakres","range":"(1 – 50000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 1 kHz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń do magnetoterapii Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 Hz do 1 kHz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen do magnetoterapii Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 1 kHz\nZakres (1 – 50000) V/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 – 180","categories":["environment"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 1 kHz"},{"name":"Range","range":"(1 – 50000) V/m"}],"search_en":"Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices Electric field strength: Direct measurement method in the frequency range from 10 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 1 kHz"},{"name":"范围","range":"(1 – 50000) V/m"}],"search_zh":"工作环境 － 使用磁疗设备时作业空间内的电磁场 电场强度： 直接测量法 频率范围自 10 Hz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","technique_zh":"直接测量法","test_object_zh":"工作环境 － 使用磁疗设备时作业空间内的电磁场"},{"_id":"6a841ec0af14b9c0e7b214b3","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń do magnetoterapii","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 1 kHz"},{"name":"Zakres","range":"50 nT – 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 10 Hz do 1 kHz\nZakres 50 nT – 19 mT\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń do magnetoterapii Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości od 10 Hz do 1 kHz\nZakres 50 nT – 19 mT\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen do magnetoterapii Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci od 10 Hz do 1 kHz\nZakres 50 nT – 19 mT\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 – 180","categories":["environment"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 1 kHz"},{"name":"Range","range":"50 nT – 19 mT"}],"search_en":"Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices Magnetic flux density: Direct measurement method in the frequency range from 10 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 1 kHz"},{"name":"范围","range":"50 nT – 19 mT"}],"search_zh":"工作环境 － 使用磁疗设备时作业空间内的电磁场 磁感应强度： 直接测量法 频率范围自 10 Hz 起 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","technique_zh":"直接测量法","methodology_zh":"磁感应强度：","test_object_zh":"工作环境 － 使用磁疗设备时作业空间内的电磁场"},{"_id":"6a841ec0af14b9c0e7b214b4","lab_id":"69ad52a3de79e566650fb5ba","country":"PL","accr_number":"AB 1121","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń do magnetoterapii","methodology":"Natężenie pola magnetycznego: (z obliczeń)","parameters":[{"name":"w zakresie częstotliwości od 10 Hz","range":"do 1 kHz"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego: (z obliczeń)\nw zakresie częstotliwości od 10 Hz do 1 kHz","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180"],"lab_section":"Zakład Badań Środowiska","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas użytkowania urządzeń do magnetoterapii Natężenie pola magnetycznego: (z obliczeń)\nw zakresie częstotliwości od 10 Hz do 1 kHz Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy podczas uzytkowania urzadzen do magnetoterapii Natezenie pola magnetycznego: (z obliczen)\nw zakresie czestotliwosci od 10 Hz do 1 kHz Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 – 180","categories":["environment"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"in the frequency range from 10 Hz","range":"do 1 kHz"}],"search_en":"Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices in the frequency range from 10 Hz Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","test_object_en":"Workplace environment - electromagnetic field in the workspace during the use of magnetotherapy devices","parameters_zh":[{"name":"频率范围自 10 Hz 起","range":"do 1 kHz"}],"search_zh":"工作环境 － 使用磁疗设备时作业空间内的电磁场 频率范围自 10 Hz 起 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 – 180","test_object_zh":"工作环境 － 使用磁疗设备时作业空间内的电磁场"}],"has_pdf":true}