🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL
Water & wastewaterMaterials & polymers
PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 1113 (Siedlce, Poland). Its accreditation scope covers 44 test methods in the following areas: Water & wastewater, Materials & polymers. Test objects include: Water, wastewater, Water Water intended for human consumption, Sewage sludge, Water intended for human consumption.
At a glance
- Accreditation number: PCA AB 1113
- Methods in scope: 44
- Types of test objects: 6
- City: Siedlce, Poland
- Accreditation number
- AB 1113
- Accreditation body
- PCA
- Address
- W SIEDLCACH, ul. Leśna 8, 08-110 Siedlce
- City
- Siedlce, Poland
What this laboratory tests (6)
- Water, wastewater — 20 methods
- Water Water intended for human consumption — 17 methods
- Sewage sludge — 3 methods
- Water intended for human consumption — 2 methods
- Surface water — 1 method
- Wastewater — 1 method
Accreditation scope — test methods (44)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Wastewater | Sampling for chemical and physical testing Manual method Automatic method Temperature of wastewater/of the wastewater sample taken Range: (0 – 50) °C | PN-ISO 5667-10:2021-11 PN-77/C-04584 | ||
| 2 | Surface water | Sampling for chemical and physical testing | PN-EN ISO 5667-6:2016-12 | ||
| 3 | Water, wastewater | pH Range: 2,0 – 12,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 4 | Water, wastewater | Chloride concentration Range: (5,0 – 2000) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 5 | Water, wastewater | Metal concentrations Range: nickel (0,050 – 10,0) mg/l copper (0,050 – 10,0) mg/l zinc (0,015 – 10,0) mg/l cadmium (0,020 – 10,0) mg/l lead (0,100 – 10,0) mg/l iron (0,050 – 20,0) mg/l manganese (0,015 – 1,00) mg/l Flame atomic absorption spectrometry method (FAAS) | PN-ISO 8288:2002 metoda A | ||
| 6 | Water, wastewater | Nitrite nitrogen concentration Range: (0,012 – 10,0) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 7 | Water, wastewater | Nitrate nitrogen concentration Range: (0,140 – 50,0) mg/l Spectrophotometric method | PN-82/C-04576.08 | ||
| 8 | Water, wastewater | Ammonium nitrogen concentration Range: (0,200 – 1000) mg/l Titrimetric method | PN-ISO 5664:2002 | ||
| 9 | Water, wastewater | Kjeldahl nitrogen concentration Range: (1,00 – 1000) mg/l Titrimetric method | PN-EN 25663:2001 | ||
| 10 | Water, wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576.14 | ||
| 11 | Water, wastewater | Chemical oxygen demand - COD Range: (30 – 50000) mg/l O 2 Titrimetric method | PN-ISO 6060:2006 | ||
| 12 | Water, wastewater | Chemical oxygen demand - COD Range: (5,0 – 150) mg/l O 2 Spectrophotometric method | PN-ISO 15705:2005 | ||
| 13 | Water, wastewater | Biochemical oxygen demand - BOD 5 Range: (1,0 – 6000) mg/l O 2 Electrochemical method | PN-EN ISO 5815-1:2019-12 | ||
| 14 | Water, wastewater | Biochemical oxygen demand - BOD 5 Range: (0,5 – 6) mg/l O 2 Electrochemical method | PN-EN 1899-2:2002 | ||
| 15 | Water, wastewater | Total suspended solids (TSS) Range: (2,0 – 10000) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 16 | Water, wastewater | Total phosphorus concentration Range: (0,050 – 70,0) mg/l Spectrophotometric method | PN-EN ISO 6878:2006 p. 8 +Ap1:2010 +Ap2:2010 | ||
| 17 | Water, wastewater | Phosphate phosphorus concentration Range: (0,030 – 70,0) mg/l Spectrophotometric method | PN-EN ISO 6878:2006 p. 4 +Ap1:2010 +Ap2:2010 | ||
| 18 | Water, wastewater | Concentration of substances extractable with petroleum ether Range: (2 – 650) mg/l Gravimetric method | PB-EE:2020 Wydanie 2 z dnia 20.11.2020 r. | ||
| 19 | Water, wastewater | Sulfate concentration Range: (10 – 5000) mg/l Gravimetric method | PN-ISO 9280:2002 | ||
| 20 | Water, wastewater | Chromium concentration Range: (0,050 – 10,0) mg/l Flame atomic absorption spectrometry method (FAAS) | PN-EN 1233:2000 p. 3 | ||
| 21 | Water, wastewater | Iron concentration Range: (0,100 – 15,0) mg/l Electrothermal atomic absorption spectrometry method (ETAAS) | PN-EN ISO 15586:2005 | ||
| 22 | Water, wastewater | Mineral oil index Range: (0,40 – 50) mg/l Gas chromatography with flame ionisation detection (GC-FID) | PN-EN ISO 9377-2:2003 | ||
| 23 | Water intended for human consumption | Metal concentrations Range: copper (0,050 – 10,0) mg/l zinc (0,015 – 10,0) mg/l manganese (15 – 1000) µg/l iron (50 – 10000) µg/l Flame atomic absorption spectrometry method (FAAS) | PN-ISO 8288:2002 metoda A | ||
| 24 | Water intended for human consumption | Metal concentrations Range: arsenic (0,0020 – 0,020) mg/l cadmium (0,00050 – 0,0100) mg/l nickel (0,0040 – 0,040) mg/l lead (0,0020 – 0,020) mg/l chromium (0,0020 – 0,100) mg/l Electrothermal atomization atomic absorption spectrometry (ETAAS) | PN-EN ISO 15586:2005 | ||
| 25 | Sewage sludge | Content of dry residue and water Range: (0,1 – 99,9) % Gravimetric method | PN-EN 12880:2004 | ||
| 26 | Sewage sludge | Loss on ignition of sludge dry matter Range: (0,1 – 99,9) % Gravimetric method | PN-EN 12879:2004 | ||
| 27 | Sewage sludge | pH Range: 2,0 – 12,0 Potentiometric method | PN-EN 12176:2004 | ||
| 28 | Water Water intended for human consumption | Sampling for chemical, physical and sensory testing | PN-ISO 5667-5:2017-10 | ||
| 29 | Water Water intended for human consumption | pH Range: 2,0 – 10,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 30 | Water Water intended for human consumption | Colour Range: (4 – 100) mg/l Pt Spectrophotometric method | PN-EN ISO 7887:2012 metoda C +Ap1:2015-06 | ||
| 31 | Water Water intended for human consumption | Turbidity Range: (0,10 – 50) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 32 | Water Water intended for human consumption | Electrical conductivity Range: (10 – 3000) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 33 | Water Water intended for human consumption | Ammonium ion concentration Range: (0,050 – 5,00) mg/l Spectrophotometric method | PN-ISO 7150-1:2002 | ||
| 34 | Water Water intended for human consumption | Nitrite concentration Range: (0,040 – 1,00) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 35 | Water Water intended for human consumption | Nitrate concentration Range: (0,200 – 100) mg/l Spectrophotometric method | PN-82/C-04576.08 | ||
| 36 | Water Water intended for human consumption | Chloride concentration Range: (5,0 – 400) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 37 | Water Water intended for human consumption | Total calcium and magnesium content (total hardness) Range: (5,0 – 500) mg/l CaCO 3 Titrimetric method | PN-ISO 6059:1999 | ||
| 38 | Water Water intended for human consumption | Permanganate index (oxidisability) Range: (0,50 – 20) mg/l Titrimetric method | PN-EN ISO 8467:2001 | ||
| 39 | Water Water intended for human consumption | Iron concentration Range: (40 – 5000) µg/l Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | ||
| 40 | Water Water intended for human consumption | Manganese concentration Range: (7 – 500) µg/l Spectrophotometric method | PB-Mn wyd.2 z dnia 01.02.2018 na podstawie testu HACH Lange LCW 532 | ||
| 41 | Water Water intended for human consumption | Calcium concentration Range: (2,0 – 200) mg/l Titrimetric method | PN-ISO 6058:1999 | ||
| 42 | Water Water intended for human consumption | Magnesium concentration (calculated) | PN-C-04554-4:1999 Załącznik A | ||
| 43 | Water Water intended for human consumption | Odour threshold number TON Range: 1 Simplified paired method, non-forced choice | PN-EN 1622:2006 | ||
| 44 | Water Water intended for human consumption | Taste threshold number TFN Range: 1 Simplified paired method, non-forced choice | |||
Reference standards (37)
PB-EE:2020 Wydanie 2 z dnia 20.11.2020 r.
PB-Mn wyd.2 z dnia 01.02.2018 na podstawie testu HACH Lange LCW 532
PN-73/C-04576.14
PN-82/C-04576.08
PN-C-04554-4:1999 Załącznik A
PN-EN 12176:2004
PN-EN 1233:2000 p. 3
PN-EN 12879:2004
PN-EN 12880:2004
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 15586:2005
PN-EN ISO 5667-6:2016-12
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 p. 4 +Ap1:2010 +Ap2:2010
PN-EN ISO 6878:2006 p. 8 +Ap1:2010 +Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
PN-EN ISO 8467:2001
PN-EN ISO 9377-2:2003
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 8288:2002 metoda A
PN-ISO 9280:2002
PN-ISO 9297:1994