{"lab":{"_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","address":"W SIEDLCACH, ul. Leśna 8, 08-110 Siedlce","categories":["water","materials"],"city":"Siedlce","imported_at":"2026-03-08T10:42:43.265Z","methods_count":44,"name":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1113.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo wodociągów i kanalizacji sp. z o.o. w siedlcach, ul. leśna 8, 08-110 siedlce water other materials food pharma electronics","status":"active","updated_at":"2026-03-08T14:50:17.599Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:17.599Z","parse_date":"2026-07-17T16:18:52.479Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://pwik.siedlce.pl/contents/content/119/56","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinkingg water, sewage"},{"codes":"N/32","pl":"Badania właściwości fizycznych osadów","en":"Tests of physical properties of sediments"},{"codes":"Q/28/P, Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Sensory tests and sampling of water, drinking water"}],"issue":{"no":"17","date":"14.11.2025"},"map_coord":[52.150852,22.243338],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":44,"materials":3,"petro":1},"category_scores":{"water":40.33,"materials":0.19,"petro":0.02},"has_zh":true},"methods":[{"_id":"6a5a55ec9af9f73f382500db","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura ścieków/pobranej próbki ścieków Zakres: (0 – 50) °C","methodology_en":"Sampling for chemical and physical testing Manual method Automatic method Temperature of wastewater/of the wastewater sample taken Range: (0 – 50) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura ścieków/pobranej próbki ścieków Zakres: (0 – 50) °C","reference":"PN-ISO 5667-10:2021-11 PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura ścieków/pobranej próbki ścieków Zakres: (0 – 50) °C PN-ISO 5667-10:2021-11 PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna Metoda automatyczna Temperatura sciekow/pobranej probki sciekow Zakres: (0 – 50) °C PN-ISO 5667-10:2021-11 PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing Manual method Automatic method Temperature of wastewater/of the wastewater sample taken Range: (0 – 50) °C PN-ISO 5667-10:2021-11 PN-77/C-04584","search_zh":"污水 PN-ISO 5667-10:2021-11 PN-77/C-04584","test_object_zh":"污水"},{"_id":"6a5a55ec9af9f73f382500dc","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda powierzchniowa","test_object_en":"Surface water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12","norm_bases":["PN-EN ISO 5667-6:2016-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda powierzchniowa Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 Woda powierzchniowa Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Surface water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12","methodology_zh":"化学与物理检测用样品采集","search_zh":"地表水 化学与物理检测用样品采集 PN-EN ISO 5667-6:2016-12","test_object_zh":"地表水"},{"_id":"6a5a55ec9af9f73f382500dd","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","methodology_en":"pH Range: 2,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater pH Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水、废水 pH 范围：2,0 – 12,0 电位法 PN-EN ISO 10523:2012","test_object_zh":"水、废水","methodology_zh":"pH 范围：2,0 – 12,0 电位法"},{"_id":"6a5a55ec9af9f73f382500de","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chlorków Zakres: (5,0 – 2000) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5,0 – 2000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,0 – 2000) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chlorków Zakres: (5,0 – 2000) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow Zakres: (5,0 – 2000) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Chloride concentration Range: (5,0 – 2000) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水、废水 氯化物浓度 范围：(5,0 – 2000) mg/l 滴定法 PN-ISO 9297:1994","test_object_zh":"水、废水","methodology_zh":"氯化物浓度 范围：(5,0 – 2000) mg/l 滴定法"},{"_id":"6a5a55ec9af9f73f382500df","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie metali Zakres: nikiel (0,050 – 10,0) mg/l miedź (0,050 – 10,0) mg/l cynk (0,015 – 10,0) mg/l kadm (0,020 – 10,0) mg/l ołów (0,100 – 10,0) mg/l żelazo (0,050 – 20,0) mg/l mangan (0,015 – 1,00) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","methodology_en":"Metal concentrations Range: nickel (0,050 – 10,0) mg/l copper (0,050 – 10,0) mg/l zinc (0,015 – 10,0) mg/l cadmium (0,020 – 10,0) mg/l lead (0,100 – 10,0) mg/l iron (0,050 – 20,0) mg/l manganese (0,015 – 1,00) mg/l Flame atomic absorption spectrometry method (FAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie metali Zakres: nikiel (0,050 – 10,0) mg/l miedź (0,050 – 10,0) mg/l cynk (0,015 – 10,0) mg/l kadm (0,020 – 10,0) mg/l ołów (0,100 – 10,0) mg/l żelazo (0,050 – 20,0) mg/l mangan (0,015 – 1,00) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie metali Zakres: nikiel (0,050 – 10,0) mg/l miedź (0,050 – 10,0) mg/l cynk (0,015 – 10,0) mg/l kadm (0,020 – 10,0) mg/l ołów (0,100 – 10,0) mg/l żelazo (0,050 – 20,0) mg/l mangan (0,015 – 1,00) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Woda, scieki Stezenie metali Zakres: nikiel (0,050 – 10,0) mg/l miedz (0,050 – 10,0) mg/l cynk (0,015 – 10,0) mg/l kadm (0,020 – 10,0) mg/l olow (0,100 – 10,0) mg/l zelazo (0,050 – 20,0) mg/l mangan (0,015 – 1,00) mg/l Metoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["materials","water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Metal concentrations Range: nickel (0,050 – 10,0) mg/l copper (0,050 – 10,0) mg/l zinc (0,015 – 10,0) mg/l cadmium (0,020 – 10,0) mg/l lead (0,100 – 10,0) mg/l iron (0,050 – 20,0) mg/l manganese (0,015 – 1,00) mg/l Flame atomic absorption spectrometry method (FAAS) PN-ISO 8288:2002 metoda A","search_zh":"水、废水 PN-ISO 8288:2002 metoda A","test_object_zh":"水、废水"},{"_id":"6a5a55ec9af9f73f382500e0","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotynowego Zakres: (0,012 – 10,0) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,012 – 10,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,012 – 10,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotynowego Zakres: (0,012 – 10,0) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego Zakres: (0,012 – 10,0) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Nitrite nitrogen concentration Range: (0,012 – 10,0) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水、废水 PN-EN 26777:1999","test_object_zh":"水、废水"},{"_id":"6a5a55ec9af9f73f382500e1","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotanowego Zakres: (0,140 – 50,0) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate nitrogen concentration Range: (0,140 – 50,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego Zakres: (0,140 – 50,0) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotanowego Zakres: (0,140 – 50,0) mg/l Metoda spektrofotometryczna PN-82/C-04576.08 Woda, scieki Stezenie azotu azotanowego Zakres: (0,140 – 50,0) mg/l Metoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Nitrate nitrogen concentration Range: (0,140 – 50,0) mg/l Spectrophotometric method PN-82/C-04576.08","search_zh":"水、废水 PN-82/C-04576.08","test_object_zh":"水、废水"},{"_id":"6a5a55ec9af9f73f382500e2","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,200 – 1000) mg/l Metoda miareczkowa","methodology_en":"Ammonium nitrogen concentration Range: (0,200 – 1000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,200 – 1000) mg/l Metoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu amonowego Zakres: (0,200 – 1000) mg/l Metoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego Zakres: (0,200 – 1000) mg/l Metoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Ammonium nitrogen concentration Range: (0,200 – 1000) mg/l Titrimetric method PN-ISO 5664:2002","search_zh":"水、废水 PN-ISO 5664:2002","test_object_zh":"水、废水"},{"_id":"6a5a55ec9af9f73f382500e3","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu Kjeldahla Zakres: (1,00 – 1000) mg/l Metoda miareczkowa","methodology_en":"Kjeldahl nitrogen concentration Range: (1,00 – 1000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (1,00 – 1000) mg/l Metoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla Zakres: (1,00 – 1000) mg/l Metoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla Zakres: (1,00 – 1000) mg/l Metoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Kjeldahl nitrogen concentration Range: (1,00 – 1000) mg/l Titrimetric method PN-EN 25663:2001","search_zh":"水、废水 凯氏氮浓度 范围：(1,00 – 1000) mg/l 滴定法 PN-EN 25663:2001","test_object_zh":"水、废水","methodology_zh":"凯氏氮浓度 范围：(1,00 – 1000) mg/l 滴定法"},{"_id":"6a5a55ec9af9f73f382500e4","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576.14","norm_bases":["PN-73/C-04576.14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576.14 Woda, scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576.14","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576.14","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PN-73/C-04576.14","test_object_zh":"水、废水"},{"_id":"6a5a55ec9af9f73f382500e5","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (30 – 50000) mg/l O 2 Metoda miareczkowa","methodology_en":"Chemical oxygen demand - COD Range: (30 – 50000) mg/l O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (30 – 50000) mg/l O 2 Metoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (30 – 50000) mg/l O 2 Metoda miareczkowa PN-ISO 6060:2006 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (30 – 50000) mg/l O 2 Metoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Chemical oxygen demand - COD Range: (30 – 50000) mg/l O 2 Titrimetric method PN-ISO 6060:2006","search_zh":"水、废水 PN-ISO 6060:2006","test_object_zh":"水、废水"},{"_id":"6a5a55ec9af9f73f382500e6","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (5,0 – 150) mg/l O 2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD Range: (5,0 – 150) mg/l O 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (5,0 – 150) mg/l O 2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (5,0 – 150) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (5,0 – 150) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Chemical oxygen demand - COD Range: (5,0 – 150) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"水、废水 PN-ISO 15705:2005","test_object_zh":"水、废水"},{"_id":"6a5a55ec9af9f73f382500e7","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6000) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (1,0 – 6000) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6000) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Biochemical oxygen demand - BOD 5 Range: (1,0 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12","search_zh":"水、废水 PN-EN ISO 5815-1:2019-12","test_object_zh":"水、废水"},{"_id":"6a5a55ec9af9f73f382500e8","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (0,5 – 6) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Biochemical oxygen demand - BOD 5 Range: (0,5 – 6) mg/l O 2 Electrochemical method PN-EN 1899-2:2002","search_zh":"水、废水 PN-EN 1899-2:2002","test_object_zh":"水、废水"},{"_id":"6a5a55ec9af9f73f382500e9","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Zawiesiny ogólne Zakres: (2,0 – 10000) mg/l Metoda wagowa","methodology_en":"Total suspended solids (TSS) Range: (2,0 – 10000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (2,0 – 10000) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Zawiesiny ogólne Zakres: (2,0 – 10000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne Zakres: (2,0 – 10000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total suspended solids (TSS) Range: (2,0 – 10000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"水、废水 总悬浮物 范围：(2,0 – 10000) mg/l 重量法 PN-EN 872:2007+Ap1:2007","test_object_zh":"水、废水","methodology_zh":"总悬浮物 范围：(2,0 – 10000) mg/l 重量法"},{"_id":"6a5a55ec9af9f73f382500ea","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,050 – 70,0) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,050 – 70,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,050 – 70,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 8 +Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p. 8 +Ap1:2010 +Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego Zakres: (0,050 – 70,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 p. 8 +Ap1:2010 +Ap2:2010 Woda, scieki Stezenie fosforu ogolnego Zakres: (0,050 – 70,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 p. 8 +Ap1:2010 +Ap2:2010","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Total phosphorus concentration Range: (0,050 – 70,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 p. 8 +Ap1:2010 +Ap2:2010","search_zh":"水、废水 PN-EN ISO 6878:2006 p. 8 +Ap1:2010 +Ap2:2010","test_object_zh":"水、废水"},{"_id":"6a5a55ec9af9f73f382500eb","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu fosforanowego Zakres: (0,030 – 70,0) mg/l Metoda spektrofotometryczna","methodology_en":"Phosphate phosphorus concentration Range: (0,030 – 70,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu fosforanowego Zakres: (0,030 – 70,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 4 +Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p. 4 +Ap1:2010 +Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu fosforanowego Zakres: (0,030 – 70,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 p. 4 +Ap1:2010 +Ap2:2010 Woda, scieki Stezenie fosforu fosforanowego Zakres: (0,030 – 70,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 p. 4 +Ap1:2010 +Ap2:2010","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Phosphate phosphorus concentration Range: (0,030 – 70,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 p. 4 +Ap1:2010 +Ap2:2010","search_zh":"水、废水 PN-EN ISO 6878:2006 p. 4 +Ap1:2010 +Ap2:2010","test_object_zh":"水、废水"},{"_id":"6a5a55ec9af9f73f382500ec","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie substancji ekstrahujących się eterem naftowym Zakres: (2 – 650) mg/l Metoda wagowa","methodology_en":"Concentration of substances extractable with petroleum ether Range: (2 – 650) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym Zakres: (2 – 650) mg/l Metoda wagowa","reference":"PB-EE:2020 Wydanie 2 z dnia 20.11.2020 r.","norm_bases":["PB-EE:2020 Wydanie 2 z dnia 20.11.2020 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie substancji ekstrahujących się eterem naftowym Zakres: (2 – 650) mg/l Metoda wagowa PB-EE:2020 Wydanie 2 z dnia 20.11.2020 r. Woda, scieki Stezenie substancji ekstrahujacych sie eterem naftowym Zakres: (2 – 650) mg/l Metoda wagowa PB-EE:2020 Wydanie 2 z dnia 20.11.2020 r.","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Concentration of substances extractable with petroleum ether Range: (2 – 650) mg/l Gravimetric method PB-EE:2020 Wydanie 2 z dnia 20.11.2020 r.","search_zh":"水、废水 PB-EE:2020 Wydanie 2 z dnia 20.11.2020 r.","test_object_zh":"水、废水"},{"_id":"6a5a55ec9af9f73f382500ed","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie siarczanów Zakres: (10 – 5000) mg/l Metoda wagowa","methodology_en":"Sulfate concentration Range: (10 – 5000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów Zakres: (10 – 5000) mg/l Metoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie siarczanów Zakres: (10 – 5000) mg/l Metoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow Zakres: (10 – 5000) mg/l Metoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Sulfate concentration Range: (10 – 5000) mg/l Gravimetric method PN-ISO 9280:2002","search_zh":"水、废水 硫酸盐浓度 范围：(10 – 5000) mg/l 重量法 PN-ISO 9280:2002","test_object_zh":"水、废水","methodology_zh":"硫酸盐浓度 范围：(10 – 5000) mg/l 重量法"},{"_id":"6a5a55ec9af9f73f382500ee","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chromu Zakres: (0,050 – 10,0) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","methodology_en":"Chromium concentration Range: (0,050 – 10,0) mg/l Flame atomic absorption spectrometry method (FAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chromu Zakres: (0,050 – 10,0) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 1233:2000 p. 3","norm_bases":["PN-EN 1233:2000 p. 3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chromu Zakres: (0,050 – 10,0) mg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000 p. 3 Woda, scieki Stezenie chromu Zakres: (0,050 – 10,0) mg/l Metoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1233:2000 p. 3","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Chromium concentration Range: (0,050 – 10,0) mg/l Flame atomic absorption spectrometry method (FAAS) PN-EN 1233:2000 p. 3","search_zh":"水、废水 PN-EN 1233:2000 p. 3","test_object_zh":"水、废水"},{"_id":"6a5a55ec9af9f73f382500ef","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie żelaza Zakres: (0,100 – 15,0) mg/l Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","methodology_en":"Iron concentration Range: (0,100 – 15,0) mg/l Electrothermal atomic absorption spectrometry method (ETAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza Zakres: (0,100 – 15,0) mg/l Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie żelaza Zakres: (0,100 – 15,0) mg/l Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, scieki Stezenie zelaza Zakres: (0,100 – 15,0) mg/l Metoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Iron concentration Range: (0,100 – 15,0) mg/l Electrothermal atomic absorption spectrometry method (ETAAS) PN-EN ISO 15586:2005","search_zh":"水、废水 PN-EN ISO 15586:2005","test_object_zh":"水、废水"},{"_id":"6a5a55ec9af9f73f382500f0","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Indeks oleju mineralnego Zakres: (0,40 – 50) mg/l Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","methodology_en":"Mineral oil index Range: (0,40 – 50) mg/l Gas chromatography with flame ionisation detection (GC-FID)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks oleju mineralnego Zakres: (0,40 – 50) mg/l Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Indeks oleju mineralnego Zakres: (0,40 – 50) mg/l Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Indeks oleju mineralnego Zakres: (0,40 – 50) mg/l Metoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water, wastewater Mineral oil index Range: (0,40 – 50) mg/l Gas chromatography with flame ionisation detection (GC-FID) PN-EN ISO 9377-2:2003","search_zh":"水、废水 PN-EN ISO 9377-2:2003","test_object_zh":"水、废水"},{"_id":"6a5a55ec9af9f73f382500f1","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie metali Zakres: miedź (0,050 – 10,0) mg/l cynk (0,015 – 10,0) mg/l mangan (15 – 1000) µg/l żelazo (50 – 10000) µg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","methodology_en":"Metal concentrations Range: copper (0,050 – 10,0) mg/l zinc (0,015 – 10,0) mg/l manganese (15 – 1000) µg/l iron (50 – 10000) µg/l Flame atomic absorption spectrometry method (FAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie metali Zakres: miedź (0,050 – 10,0) mg/l cynk (0,015 – 10,0) mg/l mangan (15 – 1000) µg/l żelazo (50 – 10000) µg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 metoda A","norm_bases":["PN-ISO 8288:2002 metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie metali Zakres: miedź (0,050 – 10,0) mg/l cynk (0,015 – 10,0) mg/l mangan (15 – 1000) µg/l żelazo (50 – 10000) µg/l Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A Woda do spozycia przez ludzi Stezenie metali Zakres: miedz (0,050 – 10,0) mg/l cynk (0,015 – 10,0) mg/l mangan (15 – 1000) µg/l zelazo (50 – 10000) µg/l Metoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 metoda A","categories":["materials","water"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Metal concentrations Range: copper (0,050 – 10,0) mg/l zinc (0,015 – 10,0) mg/l manganese (15 – 1000) µg/l iron (50 – 10000) µg/l Flame atomic absorption spectrometry method (FAAS) PN-ISO 8288:2002 metoda A","search_zh":"生活饮用水 PN-ISO 8288:2002 metoda A","test_object_zh":"生活饮用水"},{"_id":"6a5a55ec9af9f73f382500f2","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie metali Zakres: arsen (0,0020 – 0,020) mg/l kadm (0,00050 – 0,0100) mg/l nikiel (0,0040 – 0,040) mg/l ołów (0,0020 – 0,020) mg/l chrom (0,0020 – 0,100) mg/l Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","methodology_en":"Metal concentrations Range: arsenic (0,0020 – 0,020) mg/l cadmium (0,00050 – 0,0100) mg/l nickel (0,0040 – 0,040) mg/l lead (0,0020 – 0,020) mg/l chromium (0,0020 – 0,100) mg/l Electrothermal atomization atomic absorption spectrometry (ETAAS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie metali Zakres: arsen (0,0020 – 0,020) mg/l kadm (0,00050 – 0,0100) mg/l nikiel (0,0040 – 0,040) mg/l ołów (0,0020 – 0,020) mg/l chrom (0,0020 – 0,100) mg/l Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie metali Zakres: arsen (0,0020 – 0,020) mg/l kadm (0,00050 – 0,0100) mg/l nikiel (0,0040 – 0,040) mg/l ołów (0,0020 – 0,020) mg/l chrom (0,0020 – 0,100) mg/l Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda do spozycia przez ludzi Stezenie metali Zakres: arsen (0,0020 – 0,020) mg/l kadm (0,00050 – 0,0100) mg/l nikiel (0,0040 – 0,040) mg/l olow (0,0020 – 0,020) mg/l chrom (0,0020 – 0,100) mg/l Metoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["materials","water"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Metal concentrations Range: arsenic (0,0020 – 0,020) mg/l cadmium (0,00050 – 0,0100) mg/l nickel (0,0040 – 0,040) mg/l lead (0,0020 – 0,020) mg/l chromium (0,0020 – 0,100) mg/l Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005","search_zh":"生活饮用水 PN-EN ISO 15586:2005","test_object_zh":"生活饮用水"},{"_id":"6a5a55ec9af9f73f382500f3","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość suchej pozostałości i wody Zakres: (0,1 – 99,9) % Metoda wagowa","methodology_en":"Content of dry residue and water Range: (0,1 – 99,9) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość suchej pozostałości i wody Zakres: (0,1 – 99,9) % Metoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość suchej pozostałości i wody Zakres: (0,1 – 99,9) % Metoda wagowa PN-EN 12880:2004 Osady sciekowe Zawartosc suchej pozostalosci i wody Zakres: (0,1 – 99,9) % Metoda wagowa PN-EN 12880:2004","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Content of dry residue and water Range: (0,1 – 99,9) % Gravimetric method PN-EN 12880:2004","search_zh":"污泥 PN-EN 12880:2004","test_object_zh":"污泥"},{"_id":"6a5a55ec9af9f73f382500f4","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Strata przy prażeniu suchej masy osadu Zakres: (0,1 – 99,9) % Metoda wagowa","methodology_en":"Loss on ignition of sludge dry matter Range: (0,1 – 99,9) % Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Strata przy prażeniu suchej masy osadu Zakres: (0,1 – 99,9) % Metoda wagowa","reference":"PN-EN 12879:2004","norm_bases":["PN-EN 12879:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Strata przy prażeniu suchej masy osadu Zakres: (0,1 – 99,9) % Metoda wagowa PN-EN 12879:2004 Osady sciekowe Strata przy prazeniu suchej masy osadu Zakres: (0,1 – 99,9) % Metoda wagowa PN-EN 12879:2004","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Loss on ignition of sludge dry matter Range: (0,1 – 99,9) % Gravimetric method PN-EN 12879:2004","search_zh":"污泥 PN-EN 12879:2004","test_object_zh":"污泥"},{"_id":"6a5a55ec9af9f73f382500f5","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","methodology_en":"pH Range: 2,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 2,0 – 12,0 Metoda potencjometryczna","reference":"PN-EN 12176:2004","norm_bases":["PN-EN 12176:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN 12176:2004 Osady sciekowe pH Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN 12176:2004","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge pH Range: 2,0 – 12,0 Potentiometric method PN-EN 12176:2004","search_zh":"污泥 pH 范围：2,0 – 12,0 电位法 PN-EN 12176:2004","test_object_zh":"污泥","methodology_zh":"pH 范围：2,0 – 12,0 电位法"},{"_id":"6a5a55ec9af9f73f382500f6","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych, fizycznych i sensorycznych","methodology_en":"Sampling for chemical, physical and sensory testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych i sensorycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych, fizycznych i sensorycznych PN-ISO 5667-5:2017-10 Woda Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych, fizycznych i sensorycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Sampling for chemical, physical and sensory testing PN-ISO 5667-5:2017-10","search_zh":"水 生活饮用水 PN-ISO 5667-5:2017-10","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55ec9af9f73f382500f7","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"pH Zakres: 2,0 – 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 2,0 – 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 2,0 – 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi pH Zakres: 2,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda Woda do spozycia przez ludzi pH Zakres: 2,0 – 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption pH Range: 2,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水 生活饮用水 PN-EN ISO 10523:2012","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55ec9af9f73f382500f8","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Barwa Zakres: (4 – 100) mg/l Pt Metoda spektrofotometryczna","methodology_en":"Colour Range: (4 – 100) mg/l Pt Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (4 – 100) mg/l Pt Metoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 metoda C +Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Barwa Zakres: (4 – 100) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C +Ap1:2015-06 Woda Woda do spozycia przez ludzi Barwa Zakres: (4 – 100) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Colour Range: (4 – 100) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","search_zh":"水 生活饮用水 PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55ec9af9f73f382500f9","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Mętność Zakres: (0,10 – 50) NTU Metoda nefelometryczna","methodology_en":"Turbidity Range: (0,10 – 50) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,10 – 50) NTU Metoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Mętność Zakres: (0,10 – 50) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Woda do spozycia przez ludzi Metnosc Zakres: (0,10 – 50) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Turbidity Range: (0,10 – 50) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","search_zh":"水 生活饮用水 浊度 范围：(0,10 – 50) NTU 散射法 PN-EN ISO 7027-1:2016-09","test_object_zh":"水 生活饮用水","methodology_zh":"浊度 范围：(0,10 – 50) NTU 散射法"},{"_id":"6a5a55ec9af9f73f382500fa","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Przewodność elektryczna właściwa Zakres: (10 – 3000) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (10 – 3000) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (10 – 3000) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Przewodność elektryczna właściwa Zakres: (10 – 3000) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa Zakres: (10 – 3000) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Electrical conductivity Range: (10 – 3000) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"水 生活饮用水 电导率 范围：(10 – 3000) µS/cm 电导法 PN-EN 27888:1999","test_object_zh":"水 生活饮用水","methodology_zh":"电导率 范围：(10 – 3000) µS/cm 电导法"},{"_id":"6a5a55ec9af9f73f382500fb","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Stężenie jonu amonowego Zakres: (0,050 – 5,00) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium ion concentration Range: (0,050 – 5,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego Zakres: (0,050 – 5,00) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Stężenie jonu amonowego Zakres: (0,050 – 5,00) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Woda Woda do spozycia przez ludzi Stezenie jonu amonowego Zakres: (0,050 – 5,00) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Ammonium ion concentration Range: (0,050 – 5,00) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"水 生活饮用水 PN-ISO 7150-1:2002","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55ec9af9f73f382500fc","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Stężenie azotynów Zakres: (0,040 – 1,00) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite concentration Range: (0,040 – 1,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów Zakres: (0,040 – 1,00) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Stężenie azotynów Zakres: (0,040 – 1,00) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda Woda do spozycia przez ludzi Stezenie azotynow Zakres: (0,040 – 1,00) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Nitrite concentration Range: (0,040 – 1,00) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水 生活饮用水 PN-EN 26777:1999","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55ec9af9f73f382500fd","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Stężenie azotanów Zakres: (0,200 – 100) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate concentration Range: (0,200 – 100) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotanów Zakres: (0,200 – 100) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Stężenie azotanów Zakres: (0,200 – 100) mg/l Metoda spektrofotometryczna PN-82/C-04576.08 Woda Woda do spozycia przez ludzi Stezenie azotanow Zakres: (0,200 – 100) mg/l Metoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Nitrate concentration Range: (0,200 – 100) mg/l Spectrophotometric method PN-82/C-04576.08","search_zh":"水 生活饮用水 PN-82/C-04576.08","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55ec9af9f73f382500fe","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Stężenie chlorków Zakres: (5,0 – 400) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5,0 – 400) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,0 – 400) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Stężenie chlorków Zakres: (5,0 – 400) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda Woda do spozycia przez ludzi Stezenie chlorkow Zakres: (5,0 – 400) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Chloride concentration Range: (5,0 – 400) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水 生活饮用水 氯化物浓度 范围：(5,0 – 400) mg/l 滴定法 PN-ISO 9297:1994","test_object_zh":"水 生活饮用水","methodology_zh":"氯化物浓度 范围：(5,0 – 400) mg/l 滴定法"},{"_id":"6a5a55ec9af9f73f382500ff","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (5,0 – 500) mg/l CaCO 3 Metoda miareczkowa","methodology_en":"Total calcium and magnesium content (total hardness) Range: (5,0 – 500) mg/l CaCO 3 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (5,0 – 500) mg/l CaCO 3 Metoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (5,0 – 500) mg/l CaCO 3 Metoda miareczkowa PN-ISO 6059:1999 Woda Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna) Zakres: (5,0 – 500) mg/l CaCO 3 Metoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Total calcium and magnesium content (total hardness) Range: (5,0 – 500) mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999","search_zh":"水 生活饮用水 PN-ISO 6059:1999","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55ec9af9f73f38250100","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Indeks nadmanganianowy (utlenialność) Zakres: (0,50 – 20) mg/l Metoda miareczkowa","methodology_en":"Permanganate index (oxidisability) Range: (0,50 – 20) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy (utlenialność) Zakres: (0,50 – 20) mg/l Metoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Indeks nadmanganianowy (utlenialność) Zakres: (0,50 – 20) mg/l Metoda miareczkowa PN-EN ISO 8467:2001 Woda Woda do spozycia przez ludzi Indeks nadmanganianowy (utlenialnosc) Zakres: (0,50 – 20) mg/l Metoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Permanganate index (oxidisability) Range: (0,50 – 20) mg/l Titrimetric method PN-EN ISO 8467:2001","search_zh":"水 生活饮用水 PN-EN ISO 8467:2001","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55ec9af9f73f38250101","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Stężenie żelaza Zakres: (40 – 5000) µg/l Metoda spektrofotometryczna","methodology_en":"Iron concentration Range: (40 – 5000) µg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza Zakres: (40 – 5000) µg/l Metoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Stężenie żelaza Zakres: (40 – 5000) µg/l Metoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda Woda do spozycia przez ludzi Stezenie zelaza Zakres: (40 – 5000) µg/l Metoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Iron concentration Range: (40 – 5000) µg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06","search_zh":"水 生活饮用水 PN-ISO 6332:2001+Ap1:2016-06","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55ec9af9f73f38250102","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Stężenie manganu Zakres: (7 – 500) µg/l Metoda spektrofotometryczna","methodology_en":"Manganese concentration Range: (7 – 500) µg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie manganu Zakres: (7 – 500) µg/l Metoda spektrofotometryczna","reference":"PB-Mn wyd.2 z dnia 01.02.2018 na podstawie testu HACH Lange LCW 532","norm_bases":["PB-Mn wyd.2 z dnia 01.02.2018 na podstawie testu HACH Lange LCW 532"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Stężenie manganu Zakres: (7 – 500) µg/l Metoda spektrofotometryczna PB-Mn wyd.2 z dnia 01.02.2018 na podstawie testu HACH Lange LCW 532 Woda Woda do spozycia przez ludzi Stezenie manganu Zakres: (7 – 500) µg/l Metoda spektrofotometryczna PB-Mn wyd.2 z dnia 01.02.2018 na podstawie testu HACH Lange LCW 532","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Manganese concentration Range: (7 – 500) µg/l Spectrophotometric method PB-Mn wyd.2 z dnia 01.02.2018 na podstawie testu HACH Lange LCW 532","search_zh":"水 生活饮用水 PB-Mn wyd.2 z dnia 01.02.2018 na podstawie testu HACH Lange LCW 532","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55ec9af9f73f38250103","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Stężenie wapnia Zakres: (2,0 – 200) mg/l Metoda miareczkowa","methodology_en":"Calcium concentration Range: (2,0 – 200) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie wapnia Zakres: (2,0 – 200) mg/l Metoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Stężenie wapnia Zakres: (2,0 – 200) mg/l Metoda miareczkowa PN-ISO 6058:1999 Woda Woda do spozycia przez ludzi Stezenie wapnia Zakres: (2,0 – 200) mg/l Metoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Calcium concentration Range: (2,0 – 200) mg/l Titrimetric method PN-ISO 6058:1999","search_zh":"水 生活饮用水 PN-ISO 6058:1999","test_object_zh":"水 生活饮用水"},{"_id":"6a5a55ec9af9f73f38250104","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Stężenie magnezu (z obliczeń)","methodology_en":"Magnesium concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999 Załącznik A","norm_bases":["PN-C-04554-4:1999 Załącznik A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-C-04554-4:1999 Załącznik A Woda Woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-C-04554-4:1999 Zalacznik A","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Magnesium concentration (calculated) PN-C-04554-4:1999 Załącznik A","search_zh":"水 生活饮用水 镁浓度（计算值） PN-C-04554-4:1999 Załącznik A","test_object_zh":"水 生活饮用水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a5a55ec9af9f73f38250105","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Liczba progowa zapachu TON Zakres: 1 Metoda uproszczona, parzysta, wybór niewymuszony","methodology_en":"Odour threshold number TON Range: 1 Simplified paired method, non-forced choice","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba progowa zapachu TON Zakres: 1 Metoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Liczba progowa zapachu TON Zakres: 1 Metoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda Woda do spozycia przez ludzi Liczba progowa zapachu TON Zakres: 1 Metoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Odour threshold number TON Range: 1 Simplified paired method, non-forced choice PN-EN 1622:2006","search_zh":"水 生活饮用水 嗅阈值 TON 范围：1 简化法、成对法、非强制选择 PN-EN 1622:2006","test_object_zh":"水 生活饮用水","methodology_zh":"嗅阈值 TON 范围：1 简化法、成对法、非强制选择"},{"_id":"6a5a55ec9af9f73f38250106","lab_id":"69ad52a3de79e566650fb5ac","country":"PL","accr_number":"AB 1113","accr_body":"PCA","test_object":"Woda Woda do spożycia przez ludzi","test_object_en":"Water Water intended for human consumption","methodology":"Liczba progowa smaku TFN Zakres: 1 Metoda uproszczona, parzysta, wybór niewymuszony","methodology_en":"Taste threshold number TFN Range: 1 Simplified paired method, non-forced choice","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba progowa smaku TFN Zakres: 1 Metoda uproszczona, parzysta, wybór niewymuszony","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Woda do spożycia przez ludzi Liczba progowa smaku TFN Zakres: 1 Metoda uproszczona, parzysta, wybór niewymuszony Woda Woda do spozycia przez ludzi Liczba progowa smaku TFN Zakres: 1 Metoda uproszczona, parzysta, wybor niewymuszony","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Water intended for human consumption Taste threshold number TFN Range: 1 Simplified paired method, non-forced choice","search_zh":"水 生活饮用水 味阈值 TFN 范围：1 简化法、成对法、非强制选择","test_object_zh":"水 生活饮用水","methodology_zh":"味阈值 TFN 范围：1 简化法、成对法、非强制选择"}],"has_pdf":true}