🇵🇱 PRZEDSIĘBIORSTWO USŁUG OCHRONY ŚRODOWISKA PL
Environment
PRZEDSIĘBIORSTWO USŁUG OCHRONY ŚRODOWISKA is a laboratory accredited by PCA under number AB 1111 (Tarnowo Podgórne, Poland). Its accreditation scope covers 16 test methods in the following areas: Environment. Test objects include: General environment − noise from installations, equipment and indus…, Workplace environment – cold microclimate, Workplace environment – hand-arm vibration, Workplace environment – hot microclimate.
At a glance
- Accreditation number: PCA AB 1111
- Methods in scope: 16
- Types of test objects: 8
- City: Tarnowo Podgórne, Poland
- Accreditation number
- AB 1111
- Accreditation body
- PCA
- Address
- ATTMA Sp. z o.o., LABORATORIUM BADAWCZE, Batorowo, ul. Stefana Batorego 33c, 62-080 Tarnowo Podgórne
- City
- Tarnowo Podgórne, Poland
What this laboratory tests (8)
- General environment − noise from installations, equipment and industrial plants — 2 methods
- Workplace environment – cold microclimate — 2 methods
- Workplace environment – hand-arm vibration — 2 methods
- Workplace environment – hot microclimate — 2 methods
- Workplace environment – moderate microclimate — 2 methods
- Workplace environment – whole-body vibration — 2 methods
- Workplace environment − indoor electric lighting — 2 methods
- Workplace environment − noise — 2 methods
Accreditation scope — test methods (16)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment − indoor electric lighting | Illuminance Range: (10 − 5000) lx Direct measurement method | PB 51.00 wydanie 3 z dnia 20.05.2024 r. PN-E-04040-03:1983 | ||
| 2 | Workplace environment − indoor electric lighting | Illuminance uniformity (calculated) | |||
| 3 | Workplace environment − noise | A-weighted equivalent sound level A-weighted maximum sound level Range: (18,0 − 135,0) dB C-weighted peak sound level Range: (40,0 – 138,0) dB Direct measurement method | PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 p. 10 i Strategię 3 - p. 11 | ||
| 4 | Workplace environment − noise | Noise exposure level normalised to: − an 8-hour working day − an average weekly working time (calculated) A-weighted equivalent sound level during the worker's presence at the workstation (calculated) | |||
| 5 | General environment − noise from installations, equipment and industrial plants | A-weighted equivalent sound level Range: (22,0 − 135,0) dB Direct measurement method | nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. z 2023 r. poz. 1706) z wyłączeniem pkt. F | ||
| 6 | General environment − noise from installations, equipment and industrial plants | A-weighted equivalent sound level for reference time T expressed as L and L AeqD AeqN indices (calculated) | |||
| 7 | Workplace environment – hot microclimate | Air temperature Range: (10 – 60) ˚C Natural wet bulb temperature Range: (10 – 60) ˚C Blackened globe temperature Range: (10 – 60) ˚C Direct measurement method | PN-EN ISO 7243:2018-01 | ||
| 8 | Workplace environment – hot microclimate | WBGT index WBGTeff index (calculated) | |||
| 9 | Workplace environment – cold microclimate | Air temperature Range: (-30 – 10) ˚C Blackened globe temperature Range: (-30 – 15) ˚C Air humidity Range: (20 – 90) % Air velocity Range: (0,15 – 5,0) m/s Direct measurement method | PN-EN ISO 11079:2008 | ||
| 10 | Workplace environment – cold microclimate | IREQ min index IREQ neutral index twc index (calculated) | |||
| 11 | Workplace environment – moderate microclimate | Air temperature Range: (10 – 60) ˚C Blackened globe temperature Range: (10 – 60) ˚C Air humidity Range: (20 – 90) % Air velocity Range: (0,15 – 5,0) m/s Direct measurement method | PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap2:2016-04 | ||
| 12 | Workplace environment – moderate microclimate | PMV index PPD index (calculated) | |||
| 13 | Workplace environment – hand-arm vibration | Frequency-weighted r.m.s. vibration acceleration Range: (0,32 – 100) m/s2 Direct measurement method | PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11 | ||
| 14 | Workplace environment – hand-arm vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (a , a , a ) hwx hwy hwz Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (a , a , a ) hwx hwy hwz (calculated) | |||
| 15 | Workplace environment – whole-body vibration | Frequency-weighted effective vibration acceleration Range: (0,04 – 25) m/s² Direct measurement method | PN-EN 14253+A1:2011 | ||
| 16 | Workplace environment – whole-body vibration | Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4a , 1.4a , a ) wx wy wz Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4a , 1.4a , a ) wx wy wz (calculated) | |||
Reference standards (9)
PB 51.00 wydanie 3 z dnia 20.05.2024 r. PN-E-04040-03:1983
PN-EN 14253+A1:2011
PN-EN ISO 11079:2008
PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006 PN-EN ISO 7730:2006/Ap2:2016-04
PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 p. 10 i Strategię 3 - p. 11
enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz. U. z 2023 r. poz. 1706) z wyłączeniem pkt. F