🇵🇱 PRZEDSIĘBIORSTWO KOMUNALNE SP. Z O.O. PL
Water & wastewaterMicrobiology
PRZEDSIĘBIORSTWO KOMUNALNE SP. Z O.O. is a laboratory accredited by PCA under number AB 1104 (Pleszew, Poland). Its accreditation scope covers 40 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Wastewater, Water, Water, Wastewater. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Plate method (pour plate).
At a glance
- Accreditation number: PCA AB 1104
- Methods in scope: 40
- Types of test objects: 10
- Techniques used: 10
- City: Pleszew, Poland
- Accreditation number
- AB 1104
- Accreditation body
- PCA
- Address
- ul. Polna 71, 63-300 Pleszew, LABORATORIUM PK, ul. Długa 65
- City
- Pleszew, Poland
What this laboratory tests (10)
- Water intended for human consumption — 11 methods
- Wastewater — 8 methods
- Water — 7 methods
- Water, Wastewater — 4 methods
- Swimming pool water — 3 methods
- Water (including swimming pool water) — 2 methods
- Woda (w tym woda na pływalniach), Ścieki — 2 methods
- Sewage sludge — 1 method
- Water (including swimming pool water), Water intended for human consumption — 1 method
- Water intended for human consumption, Swimming pool water — 1 method
Analytical techniques used (10)
- Spectrophotometric method — 14 methods
- Membrane filtration method — 6 methods
- Plate method (pour plate) — 3 methods
- Simplified method, paired, non-forced choice — 2 methods
- Conductometric method — 1 method
- Electrochemical method — 1 method
- Gravimetric method — 1 method
- Metoda manualna / metoda automatyczna — 1 method
- Nephelometric method — 1 method
- Potentiometric method — 1 method
Laboratory sections (2)
- Laboratorium PK; Pracownia fizykochemii — 30 methods
- Laboratorium PK; Pracownia mikrobiologii — 10 methods
Laboratory locations
- LABORATORIUM PK — ul. Długa 65, 63-300 Zielona Łąka
- Pracownia fizykochemii — ul. Długa 65, 63-300 Zielona Łąka
- Pracownia mikrobiologii — ul. Długa 65, 63-300 Zielona Łąka
Accreditation scope — test methods (40)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratorium PK; Pracownia fizykochemii | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing (including sensory testing) | PN-ISO 5667-5:2017-10 | ||
| 2 | Water intended for human consumption | Temperature Range (5 – 20) °C |
PBL-19 wydanie 04 z dnia 01.03.2022 r. | ||
| 3 | Water intended for human consumption | Obecność obcego zapachu (metoda jakościowa) | PN-EN 1622:2006 | ||
| 4 | Water intended for human consumption | Odour threshold number TON Range 1 – 2 |
Simplified method, paired, non-forced choice | PN-EN 1622:2006 | |
| 5 | Water intended for human consumption | Obecność obcego smaku (metoda jakościowa) | PN-EN 1622:2006 | ||
| 6 | Water intended for human consumption | Taste threshold number TFN Range 1 – 2 |
Simplified method, paired, non-forced choice | PN-EN 1622:2006 | |
| 7 | Water | Sampling for chemical and physical testing | PN-ISO 5667-4:2017-10 p. 12 | PN-EN ISO 5667-6:2016-12 p. 7.4 | ||
| 8 | Water | Temperature Range (5 – 60) °C |
PBL-19 wydanie 04 z dnia 01.03.2022 r. | ||
| 9 | Water | Total iron concentration Range (30 – 2000) µg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 10 | Water | Manganese concentration Range (15 – 5000) µg/l |
Spectrophotometric method | PBL-05 wydanie 06 z dnia 01.09.2021 r. na podstawie testu kuwetowego Nanocolor nr 918 60 | |
| 11 | Water | Colour Range (5 − 50) mg/l |
Spectrophotometric method | PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06 | |
| 12 | Water | Electrical conductivity Range (100 – 2500) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 13 | Water | Fluoride concentration Range (0,1 – 2,0) mg/l |
Spectrophotometric method | PBL-08 wydanie 3 z dnia 01.09.2021 r. na podstawie testu kuwetowego Nanocolor nr 985 040 | |
| 14 | Water (including swimming pool water) | Turbidity Range (0,20 − 15) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 15 | Water (including swimming pool water) | Free chlorine concentration Range (0,02 – 1,8) mg/l |
Spectrophotometric method | PBL-16 wydanie 03 z dnia 01.09.2021 r. na podstawie testu HACH nr 8021 | |
| 16 | Woda (w tym woda na pływalniach), Ścieki | Nitrate nitrogen concentration Range (0,03 – 20,00) mg/l N-NO 3 |
Spectrophotometric method | PN-82/C-04576/08 | |
| 17 | Woda (w tym woda na pływalniach), Ścieki | pH Range (4,0 – 10,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 18 | Water, Wastewater | Chloride concentration Range (0,2 – 250) mg/l |
Spectrophotometric method | PBL-09 wydanie 04 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 019 | |
| 19 | Water, Wastewater | Ammonium nitrogen concentration Range (0,05 – 10,00) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 20 | Water, Wastewater | Nitrite nitrogen concentration Range (0,002 – 1,00) mg/l N-NO 2 |
Spectrophotometric method | PN-ISO 26777:1999 | |
| 21 | Water, Wastewater | Sulfate concentration Range (30 – 250) mg/l |
Spectrophotometric method | PBL-29 wydanie 02 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 062 | |
| 22 | Wastewater | Sampling for chemical and physical testing | Metoda manualna / metoda automatyczna | PN-ISO 5667-10:2021-11 | |
| 23 | Wastewater | Temperature Range (5 – 30) °C |
PBL-19 wydanie 04 z dnia 01.03.2022 r. | ||
| 24 | Wastewater | Chemical oxygen demand - COD Range (5 – 10000) mg/l O 2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 25 | Wastewater | Biochemical oxygen demand - BOD5 Range (3 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 26 | Wastewater | Total suspended solids (TSS) Range (2 – 500) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 27 | Wastewater | Total nitrogen concentration Range (3,0 − 60) mg/l |
Spectrophotometric method | PBL-27 wydanie 02 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 092 | |
| 28 | Wastewater | Total phosphorus concentration Range (0,5 − 15) mg/l |
Spectrophotometric method | PBL-28 wydanie 05 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 080 | |
| 29 | Wastewater | Total iron concentration Range (0,2 − 4) mg/l |
Spectrophotometric method | PN-ISO 6332:2001+A1:2016-06 | |
| 30 | Sewage sludge | Sampling for chemical, physical and biological testing | PN-EN ISO 5667-13:2011 | ||
| Laboratorium PK; Pracownia mikrobiologii | |||||
| 31 | Water intended for human consumption, Swimming pool water | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 32 | Water intended for human consumption | Total viable count at 22°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 33 | Water intended for human consumption | Total viable count at 36°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 34 | Water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 | |
| 35 | Water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 | |
| 36 | Water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 37 | Swimming pool water | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 38 | Swimming pool water | Total viable count at 36°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 39 | Swimming pool water | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 | |
| 40 | Water (including swimming pool water), Water intended for human consumption | Count of bacteria of the genus Legionella Matrix A Procedura 5 (pożywka A-BCYE) Procedure 7 (C-GVPC medium) |
Membrane filtration method | PN-EN ISO 11731:2017-08 +Ap1:2019-12 | |
Reference standards (33)
PBL-05 wydanie 06 z dnia 01.09.2021 r. na podstawie testu kuwetowego Nanocolor nr 918 60
PBL-08 wydanie 3 z dnia 01.09.2021 r. na podstawie testu kuwetowego Nanocolor nr 985 040
PBL-09 wydanie 04 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 019
PBL-16 wydanie 03 z dnia 01.09.2021 r. na podstawie testu HACH nr 8021
PBL-19 wydanie 04 z dnia 01.03.2022 r.
PBL-27 wydanie 02 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 092
PBL-28 wydanie 05 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 080
PBL-29 wydanie 02 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 062
PN-82/C-04576/08
PN-EN 1622:2006
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 +Ap1:2019-12
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007
PN-EN ISO 5667-13:2011
PN-EN ISO 5667-6:2016-12 p. 7.4
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12/A1:2017-04
PN-ISO 15705:2005
PN-ISO 26777:1999
PN-ISO 5667-10:2021-11
PN-ISO 5667-4:2017-10 p. 12
PN-ISO 5667-5:2017-10
PN-ISO 6332:2001+A1:2016-06
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002