{"lab":{"_id":"69ad52a3de79e566650fb59c","accr_number":"AB 1104","country":"PL","accr_body":"PCA","address":"ul. Polna 71, 63-300 Pleszew, LABORATORIUM PK, ul. Długa 65","categories":["water","microbiology"],"city":"Pleszew","imported_at":"2026-03-08T10:42:43.265Z","methods_count":40,"name":"PRZEDSIĘBIORSTWO KOMUNALNE SP. Z O.O.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1104.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo komunalne sp. z o.o. ul. polna 71, 63-300 pleszew, laboratorium pk, ul. długa 65 water other pharma electronics microbiology automotive","status":"active","updated_at":"2026-03-08T14:50:17.141Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-14T13:29:14.541Z","parse_date":"2026-08-14T13:29:14.541Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://pkpleszew.pl/kontakt/","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"},{"codes":"Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody do spożycia przez ludzi","en":"Sensory tests and sampling of drinking water"},{"codes":"P/32","pl":"Pobieranie próbek osadów","en":"Sampling of sediments"}],"issue":{"no":"22","date":"09.07.2026"},"map_coord":[51.89167,17.814048],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM PK","address":"ul. Długa 65, 63-300 Zielona Łąka","city":"Zielona Łąka","postal":"63-300"},{"name":"Pracownia fizykochemii","address":"ul. Długa 65, 63-300 Zielona Łąka","city":"Zielona Łąka","postal":"63-300"},{"name":"Pracownia mikrobiologii","address":"ul. Długa 65, 63-300 Zielona Łąka","city":"Zielona Łąka","postal":"63-300"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/14/cc629efd076d4431c70efe2abf8abefa/AB%201104.pdf","has_en":true,"category_counts":{"water":40,"microbiology":5},"category_scores":{"water":35.56,"microbiology":0.56},"has_zh":true},"methods":[{"_id":"6a7f182a1995264369d8e5a1","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing (including sensory testing)","search_en":"Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 化学和物理检测采样（含感官检测） PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水","methodology_zh":"化学和物理检测采样（含感官检测）"},{"_id":"6a7f182a1995264369d8e5a2","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(5 – 20) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (5 – 20) °C","reference":"PBL-19 wydanie 04 z dnia 01.03.2022 r.","norm_bases":["PBL-19 wydanie 04 z dnia 01.03.2022 r."],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Temperatura\nZakres (5 – 20) °C PBL-19 wydanie 04 z dnia 01.03.2022 r. Woda do spozycia przez ludzi Temperatura\nZakres (5 – 20) °C PBL-19 wydanie 04 z dnia 01.03.2022 r.","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(5 – 20) °C"}],"search_en":"Water intended for human consumption Temperature Range PBL-19 wydanie 04 z dnia 01.03.2022 r.","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(5 – 20) °C"}],"search_zh":"生活饮用水 温度 范围 PBL-19 wydanie 04 z dnia 01.03.2022 r.","test_object_zh":"生活饮用水","methodology_zh":"温度"},{"_id":"6a7f182a1995264369d8e5a3","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Obecność obcego zapachu (metoda jakościowa)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Obecność obcego zapachu (metoda jakościowa)","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Obecność obcego zapachu (metoda jakościowa) PN-EN 1622:2006 Woda do spozycia przez ludzi Obecnosc obcego zapachu (metoda jakosciowa) PN-EN 1622:2006","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water intended for human consumption PN-EN 1622:2006","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 PN-EN 1622:2006","test_object_zh":"生活饮用水"},{"_id":"6a7f182a1995264369d8e5a4","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa zapachu TON","parameters":[{"name":"Zakres","range":"1 – 2"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa zapachu TON\nZakres 1 – 2\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa zapachu TON\nZakres 1 – 2\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa zapachu TON\nZakres 1 – 2\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Odour threshold number TON","parameters_en":[{"name":"Range","range":"1 – 2"}],"search_en":"Water intended for human consumption Odour threshold number TON Simplified method, paired, non-forced choice Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"1 – 2"}],"search_zh":"生活饮用水 嗅阈值 TON 简化法，成对，非强制选择 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"嗅阈值 TON"},{"_id":"6a7f182a1995264369d8e5a5","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Obecność obcego smaku (metoda jakościowa)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Obecność obcego smaku (metoda jakościowa)","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Obecność obcego smaku (metoda jakościowa) PN-EN 1622:2006 Woda do spozycia przez ludzi Obecnosc obcego smaku (metoda jakosciowa) PN-EN 1622:2006","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water intended for human consumption PN-EN 1622:2006","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 PN-EN 1622:2006","test_object_zh":"生活饮用水"},{"_id":"6a7f182a1995264369d8e5a6","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa smaku TFN","parameters":[{"name":"Zakres","range":"1 – 2"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa smaku TFN\nZakres 1 – 2\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku TFN\nZakres 1 – 2\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa smaku TFN\nZakres 1 – 2\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Taste threshold number TFN","parameters_en":[{"name":"Range","range":"1 – 2"}],"search_en":"Water intended for human consumption Taste threshold number TFN Simplified method, paired, non-forced choice Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"1 – 2"}],"search_zh":"生活饮用水 味阈值 TFN 简化法，成对，非强制选择 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","technique_zh":"简化法，成对，非强制选择","methodology_zh":"味阈值 TFN"},{"_id":"6a7f182a1995264369d8e5a7","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-4:2017-10 p. 12 | PN-EN ISO 5667-6:2016-12 p. 7.4","norm_bases":["PN-ISO 5667-4:2017-10 p. 12","PN-EN ISO 5667-6:2016-12 p. 7.4"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-4:2017-10 p. 12 | PN-EN ISO 5667-6:2016-12 p. 7.4 Woda Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-4:2017-10 p. 12 | PN-EN ISO 5667-6:2016-12 p. 7.4","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing PN-ISO 5667-4:2017-10 p. 12 | PN-EN ISO 5667-6:2016-12 p. 7.4","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-ISO 5667-4:2017-10 p. 12 | PN-EN ISO 5667-6:2016-12 p. 7.4","test_object_zh":"水"},{"_id":"6a7f182a1995264369d8e5a8","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(5 – 60) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (5 – 60) °C","reference":"PBL-19 wydanie 04 z dnia 01.03.2022 r.","norm_bases":["PBL-19 wydanie 04 z dnia 01.03.2022 r."],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura\nZakres (5 – 60) °C PBL-19 wydanie 04 z dnia 01.03.2022 r. Woda Temperatura\nZakres (5 – 60) °C PBL-19 wydanie 04 z dnia 01.03.2022 r.","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(5 – 60) °C"}],"search_en":"Water Temperature Range PBL-19 wydanie 04 z dnia 01.03.2022 r.","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(5 – 60) °C"}],"search_zh":"水 温度 范围 PBL-19 wydanie 04 z dnia 01.03.2022 r.","test_object_zh":"水","methodology_zh":"温度"},{"_id":"6a7f182a1995264369d8e5a9","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(30 – 2000) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (30 – 2000) µg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie żelaza ogólnego\nZakres (30 – 2000) µg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda Stezenie zelaza ogolnego\nZakres (30 – 2000) µg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(30 – 2000) µg/l"}],"search_en":"Water Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(30 – 2000) µg/l"}],"search_zh":"水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a7f182a1995264369d8e5aa","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(15 – 5000) µg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (15 – 5000) µg/l\nMetoda spektrofotometryczna","reference":"PBL-05 wydanie 06 z dnia 01.09.2021 r. na podstawie testu kuwetowego Nanocolor nr 918 60","norm_bases":["PBL-05 wydanie 06 z dnia 01.09.2021 r. na podstawie testu kuwetowego Nanocolor nr 918 60"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie manganu\nZakres (15 – 5000) µg/l\nMetoda spektrofotometryczna PBL-05 wydanie 06 z dnia 01.09.2021 r. na podstawie testu kuwetowego Nanocolor nr 918 60 Woda Stezenie manganu\nZakres (15 – 5000) µg/l\nMetoda spektrofotometryczna PBL-05 wydanie 06 z dnia 01.09.2021 r. na podstawie testu kuwetowego Nanocolor nr 918 60","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(15 – 5000) µg/l"}],"search_en":"Water Manganese concentration Spectrophotometric method Range PBL-05 wydanie 06 z dnia 01.09.2021 r. na podstawie testu kuwetowego Nanocolor nr 918 60","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(15 – 5000) µg/l"}],"search_zh":"水 锰浓度 分光光度法 范围 PBL-05 wydanie 06 z dnia 01.09.2021 r. na podstawie testu kuwetowego Nanocolor nr 918 60","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a7f182a1995264369d8e5ab","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 − 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5 − 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Barwa\nZakres (5 − 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06 Woda Barwa\nZakres (5 − 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 − 50) mg/l"}],"search_en":"Water Colour Spectrophotometric method Range PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 − 50) mg/l"}],"search_zh":"水 色度 分光光度法 范围 PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a7f182a1995264369d8e5ac","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 – 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Przewodność elektryczna właściwa\nZakres (100 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa\nZakres (100 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 – 2500) μS/cm"}],"search_en":"Water Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 2500) μS/cm"}],"search_zh":"水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水"},{"_id":"6a7f182a1995264369d8e5ad","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,1 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,1 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PBL-08 wydanie 3 z dnia 01.09.2021 r. na podstawie testu kuwetowego Nanocolor nr 985 040","norm_bases":["PBL-08 wydanie 3 z dnia 01.09.2021 r. na podstawie testu kuwetowego Nanocolor nr 985 040"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie fluorków\nZakres (0,1 – 2,0) mg/l\nMetoda spektrofotometryczna PBL-08 wydanie 3 z dnia 01.09.2021 r. na podstawie testu kuwetowego Nanocolor nr 985 040 Woda Stezenie fluorkow\nZakres (0,1 – 2,0) mg/l\nMetoda spektrofotometryczna PBL-08 wydanie 3 z dnia 01.09.2021 r. na podstawie testu kuwetowego Nanocolor nr 985 040","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride concentration","parameters_en":[{"name":"Range","range":"(0,1 – 2,0) mg/l"}],"search_en":"Water Fluoride concentration Spectrophotometric method Range PBL-08 wydanie 3 z dnia 01.09.2021 r. na podstawie testu kuwetowego Nanocolor nr 985 040","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,1 – 2,0) mg/l"}],"search_zh":"水 氟化物浓度 分光光度法 范围 PBL-08 wydanie 3 z dnia 01.09.2021 r. na podstawie testu kuwetowego Nanocolor nr 985 040","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"氟化物浓度"},{"_id":"6a7f182a1995264369d8e5ae","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 − 15) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 − 15) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Mętność\nZakres (0,20 − 15) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda (w tym woda na plywalniach) Metnosc\nZakres (0,20 − 15) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 − 15) NTU"}],"search_en":"Water (including swimming pool water) Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 − 15) NTU"}],"search_zh":"水（含游泳池水） 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水（含游泳池水）"},{"_id":"6a7f182a1995264369d8e5af","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,02 – 1,8) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,02 – 1,8) mg/l\nMetoda spektrofotometryczna","reference":"PBL-16 wydanie 03 z dnia 01.09.2021 r. na podstawie testu HACH nr 8021","norm_bases":["PBL-16 wydanie 03 z dnia 01.09.2021 r. na podstawie testu HACH nr 8021"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Stężenie chloru wolnego\nZakres (0,02 – 1,8) mg/l\nMetoda spektrofotometryczna PBL-16 wydanie 03 z dnia 01.09.2021 r. na podstawie testu HACH nr 8021 Woda (w tym woda na plywalniach) Stezenie chloru wolnego\nZakres (0,02 – 1,8) mg/l\nMetoda spektrofotometryczna PBL-16 wydanie 03 z dnia 01.09.2021 r. na podstawie testu HACH nr 8021","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,02 – 1,8) mg/l"}],"search_en":"Water (including swimming pool water) Free chlorine concentration Spectrophotometric method Range PBL-16 wydanie 03 z dnia 01.09.2021 r. na podstawie testu HACH nr 8021","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 1,8) mg/l"}],"search_zh":"水（含游泳池水） 游离氯浓度 分光光度法 范围 PBL-16 wydanie 03 z dnia 01.09.2021 r. na podstawie testu HACH nr 8021","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）"},{"_id":"6a7f182a1995264369d8e5b0","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,03 – 20,00) mg/l N-NO 3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,03 – 20,00) mg/l N-NO 3\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Ścieki Stężenie azotu azotanowego\nZakres (0,03 – 20,00) mg/l N-NO 3\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda (w tym woda na plywalniach), Scieki Stezenie azotu azotanowego\nZakres (0,03 – 20,00) mg/l N-NO 3\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,03 – 20,00) mg/l N-NO 3"}],"search_en":"Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,03 – 20,00) mg/l N-NO 3"}],"search_zh":"硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法"},{"_id":"6a7f182a1995264369d8e5b1","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"(4,0 – 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Ścieki pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda (w tym woda na plywalniach), Scieki pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(4,0 – 10,0)"}],"search_en":"pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(4,0 – 10,0)"}],"search_zh":"pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法"},{"_id":"6a7f182a1995264369d8e5b2","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(0,2 – 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chlorków\nZakres (0,2 – 250) mg/l\nMetoda spektrofotometryczna","reference":"PBL-09 wydanie 04 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 019","norm_bases":["PBL-09 wydanie 04 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 019"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie chlorków\nZakres (0,2 – 250) mg/l\nMetoda spektrofotometryczna PBL-09 wydanie 04 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 019 Woda, Scieki Stezenie chlorkow\nZakres (0,2 – 250) mg/l\nMetoda spektrofotometryczna PBL-09 wydanie 04 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 019","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(0,2 – 250) mg/l"}],"search_en":"Water, Wastewater Chloride concentration Spectrophotometric method Range PBL-09 wydanie 04 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 019","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(0,2 – 250) mg/l"}],"search_zh":"水、污水 氯化物浓度 分光光度法 范围 PBL-09 wydanie 04 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 019","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a7f182a1995264369d8e5b3","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 10,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,05 – 10,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (0,05 – 10,00) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (0,05 – 10,00) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,05 – 10,00) mg/l"}],"search_en":"Water, Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 10,00) mg/l"}],"search_zh":"水、污水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a7f182a1995264369d8e5b4","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,002 – 1,00) mg/l N-NO 2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,002 – 1,00) mg/l N-NO 2\nMetoda spektrofotometryczna","reference":"PN-ISO 26777:1999","norm_bases":["PN-ISO 26777:1999"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres (0,002 – 1,00) mg/l N-NO 2\nMetoda spektrofotometryczna PN-ISO 26777:1999 Woda, Scieki Stezenie azotu azotynowego\nZakres (0,002 – 1,00) mg/l N-NO 2\nMetoda spektrofotometryczna PN-ISO 26777:1999","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,002 – 1,00) mg/l N-NO 2"}],"search_en":"Water, Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-ISO 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,002 – 1,00) mg/l N-NO 2"}],"search_zh":"水、污水 亚硝态氮浓度 分光光度法 范围 PN-ISO 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a7f182a1995264369d8e5b5","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(30 – 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (30 – 250) mg/l\nMetoda spektrofotometryczna","reference":"PBL-29 wydanie 02 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 062","norm_bases":["PBL-29 wydanie 02 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 062"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie siarczanów\nZakres (30 – 250) mg/l\nMetoda spektrofotometryczna PBL-29 wydanie 02 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 062 Woda, Scieki Stezenie siarczanow\nZakres (30 – 250) mg/l\nMetoda spektrofotometryczna PBL-29 wydanie 02 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 062","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(30 – 250) mg/l"}],"search_en":"Water, Wastewater Sulfate concentration Spectrophotometric method Range PBL-29 wydanie 02 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 062","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(30 – 250) mg/l"}],"search_zh":"水、污水 硫酸盐浓度 分光光度法 范围 PBL-29 wydanie 02 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 062","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a7f182a1995264369d8e5b6","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna / metoda automatyczna","techniques":["Metoda manualna / metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna / metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna / metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna / metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing PN-ISO 5667-10:2021-11","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 PN-ISO 5667-10:2021-11","test_object_zh":"污水"},{"_id":"6a7f182a1995264369d8e5b7","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(5 – 30) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (5 – 30) °C","reference":"PBL-19 wydanie 04 z dnia 01.03.2022 r.","norm_bases":["PBL-19 wydanie 04 z dnia 01.03.2022 r."],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura\nZakres (5 – 30) °C PBL-19 wydanie 04 z dnia 01.03.2022 r. Scieki Temperatura\nZakres (5 – 30) °C PBL-19 wydanie 04 z dnia 01.03.2022 r.","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(5 – 30) °C"}],"search_en":"Wastewater Temperature Range PBL-19 wydanie 04 z dnia 01.03.2022 r.","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(5 – 30) °C"}],"search_zh":"污水 温度 范围 PBL-19 wydanie 04 z dnia 01.03.2022 r.","test_object_zh":"污水","methodology_zh":"温度"},{"_id":"6a7f182a1995264369d8e5b8","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT","parameters":[{"name":"Zakres","range":"(5 – 10000) mg/l O 2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (5 – 10000) mg/l O 2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (5 – 10000) mg/l O 2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (5 – 10000) mg/l O 2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD","parameters_en":[{"name":"Range","range":"(5 – 10000) mg/l O 2"}],"search_en":"Wastewater Chemical oxygen demand - COD Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"化学需氧量 ChZT（COD）","parameters_zh":[{"name":"范围","range":"(5 – 10000) mg/l O 2"}],"search_zh":"污水 化学需氧量 ChZT（COD） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f182a1995264369d8e5b9","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a7f182a1995264369d8e5ba","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2 – 500) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2 – 500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2 – 500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2 – 500) mg/l"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2 – 500) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a7f182a1995264369d8e5bb","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(3,0 − 60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (3,0 − 60) mg/l\nMetoda spektrofotometryczna","reference":"PBL-27 wydanie 02 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 092","norm_bases":["PBL-27 wydanie 02 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 092"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (3,0 − 60) mg/l\nMetoda spektrofotometryczna PBL-27 wydanie 02 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 092 Scieki Stezenie azotu ogolnego\nZakres (3,0 − 60) mg/l\nMetoda spektrofotometryczna PBL-27 wydanie 02 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 092","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(3,0 − 60) mg/l"}],"search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Range PBL-27 wydanie 02 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 092","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(3,0 − 60) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 范围 PBL-27 wydanie 02 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 092","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f182a1995264369d8e5bc","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,5 − 15) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,5 − 15) mg/l\nMetoda spektrofotometryczna","reference":"PBL-28 wydanie 05 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 080","norm_bases":["PBL-28 wydanie 05 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 080"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,5 − 15) mg/l\nMetoda spektrofotometryczna PBL-28 wydanie 05 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 080 Scieki Stezenie fosforu ogolnego\nZakres (0,5 − 15) mg/l\nMetoda spektrofotometryczna PBL-28 wydanie 05 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 080","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,5 − 15) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PBL-28 wydanie 05 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 080","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,5 − 15) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PBL-28 wydanie 05 z dnia 01.03.2022 r. na podstawie testu kuwetowego Nanocolor nr 985 080","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f182a1995264369d8e5bd","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,2 − 4) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,2 − 4) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+A1:2016-06","norm_bases":["PN-ISO 6332:2001+A1:2016-06"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie żelaza ogólnego\nZakres (0,2 − 4) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+A1:2016-06 Scieki Stezenie zelaza ogolnego\nZakres (0,2 − 4) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+A1:2016-06","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,2 − 4) mg/l"}],"search_en":"Wastewater Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001+A1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,2 − 4) mg/l"}],"search_zh":"污水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001+A1:2016-06","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f182a1995264369d8e5be","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań chemicznych, fizycznych i biologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych i biologicznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":"Laboratorium PK; Pracownia fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych, fizycznych i biologicznych PN-EN ISO 5667-13:2011 Osady sciekowe Pobieranie probek do badan chemicznych, fizycznych i biologicznych PN-EN ISO 5667-13:2011","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical and biological testing","search_en":"Sewage sludge Sampling for chemical, physical and biological testing PN-EN ISO 5667-13:2011","test_object_en":"Sewage sludge","search_zh":"污泥 用于化学、物理与生物检验的采样 PN-EN ISO 5667-13:2011","test_object_zh":"污泥","methodology_zh":"用于化学、物理与生物检验的采样"},{"_id":"6a7f182a1995264369d8e5bf","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Laboratorium PK; Pracownia mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi, Woda na plywalniach Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption, Swimming pool water Sampling for microbiological testing PN-EN ISO 19458:2007","test_object_en":"Water intended for human consumption, Swimming pool water","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水、游泳池水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a7f182a1995264369d8e5c0","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium PK; Pracownia mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 22°C","search_en":"Water intended for human consumption Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","methodology_zh":"22°C 微生物总数","search_zh":"生活饮用水 22°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a7f182a1995264369d8e5c1","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium PK; Pracownia mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 36°C","search_en":"Water intended for human consumption Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","methodology_zh":"36°C 微生物总数","search_zh":"生活饮用水 36°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a7f182a1995264369d8e5c2","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Laboratorium PK; Pracownia mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a7f182a1995264369d8e5c3","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Laboratorium PK; Pracownia mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a7f182a1995264369d8e5c4","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium PK; Pracownia mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a7f182a1995264369d8e5c5","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Laboratorium PK; Pracownia mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","methodology_zh":"铜绿假单胞菌计数","search_zh":"游泳池水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a7f182a1995264369d8e5c6","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Ogólna liczba mikroorganizmów w 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium PK; Pracownia mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda na plywalniach Ogolna liczba mikroorganizmow w 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 36°C","search_en":"Swimming pool water Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Swimming pool water","methodology_zh":"36°C 微生物总数","search_zh":"游泳池水 36°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"游泳池水"},{"_id":"6a7f182a1995264369d8e5c7","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Laboratorium PK; Pracownia mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a7f182a1995264369d8e5c8","lab_id":"69ad52a3de79e566650fb59c","country":"PL","accr_number":"AB 1104","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Liczba bakterii z rodzaju Legionella","parameters":[{"name":"Matryca A","range":null},{"name":"Procedura 5 (pożywka A-BCYE)","range":null},{"name":"Procedura 7 (pożywka C-GVPC)","range":null}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella\nZakres:\nMatryca A\nProcedura 5 (pożywka A-BCYE)\nProcedura 7 (pożywka C-GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":"Laboratorium PK; Pracownia mikrobiologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella\nZakres:\nMatryca A\nProcedura 5 (pożywka A-BCYE)\nProcedura 7 (pożywka C-GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella\nZakres:\nMatryca A\nProcedura 5 (pozywka A-BCYE)\nProcedura 7 (pozywka C-GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of bacteria of the genus Legionella","parameters_en":[{"name":"Matrix A","range":null},{"name":"Procedura 5 (pożywka A-BCYE)","range":null},{"name":"Procedure 7 (C-GVPC medium)","range":null}],"search_en":"Water (including swimming pool water), Water intended for human consumption Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 7 (C-GVPC medium) PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 军团菌属细菌计数 膜过滤法 PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_zh":"膜过滤法","methodology_zh":"军团菌属细菌计数","test_object_zh":"水（含游泳池水）、生活饮用水"}],"has_pdf":true}