PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI is a laboratory accredited by PCA under number AB 1099 (Ostróda, Poland). Its accreditation scope covers 48 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Wastewater, Water intended for human consumption, Water (including swimming pool water), Water intended for human con…, Water, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Ion chromatography with conductometric detection (IC-CD).
At a glance
- Accreditation number: PCA AB 1099
- Methods in scope: 48
- Types of test objects: 12
- Techniques used: 14
- City: Ostróda, Poland
- Accreditation number
- AB 1099
- Accreditation body
- PCA
- Address
- OSTRÓDA Sp. z o.o., Tyrowo 104, 14-100 Ostróda, LABORATORIUM ANALIZY WODY I ŚCIEKÓW
- City
- Ostróda, Poland
What this laboratory tests (12)
- Water, Wastewater — 8 methods
- Water intended for human consumption — 7 methods
- Water (including swimming pool water), Water intended for human consumption — 6 methods
- Water, Water intended for human consumption — 6 methods
- Water, Water intended for human consumption, Wastewater — 6 methods
- Swimming pool water — 4 methods
- Wastewater — 4 methods
- Swimming pool water, Water intended for human consumption — 3 methods
- Water — 1 method
- Water (including bathing water), Water intended for human consumption — 1 method
- Water (including swimming pool water, bathing water) — 1 method
- Water (including swimming pool water), Water intended for human consumption, Wastewater — 1 method
Analytical techniques used (14)
- Spectrophotometric method — 12 methods
- Membrane filtration method — 7 methods
- Ion chromatography with conductometric detection (IC-CD) — 3 methods
- Titrimetric method — 3 methods
- Electrochemical method — 2 methods
- Gravimetric method — 2 methods
- MPN method — 2 methods
- Plate method (pour plate) — 2 methods
- Potentiometric method — 2 methods
- Simplified method, paired, non-forced choice — 2 methods
- Automatic method; Manual method — 1 method
- Conductometric method — 1 method
- Manual and automatic method — 1 method
- Nephelometric method — 1 method
Laboratory locations
- LABORATORIUM ANALIZY WODY I ŚCIEKÓW — AB 1099 ul. 21 Stycznia 34
Accreditation scope — test methods (48)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Water and Wastewater Analysis Laboratory | |||||
| 1 | Water | Sampling for chemical and physical testing Temperature Range (5,0 – 50,0) °C |
Automatic method; Manual method | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r. | |
| 2 | Water intended for human consumption | Sampling for chemical and physical testing (including sensory testing) Temperature Range (5,0 – 50,0) °C |
PN-ISO 5667-5:2017-10 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r. | ||
| 3 | Water intended for human consumption | Manganese concentration Range (15,0 – 700) μg/l |
Spectrophotometric method | PB-FCH-02 wydanie 05 z dnia 03.06.2019 r. na podstawie testu Hach-Lange Nr 8149 | |
| 4 | Water intended for human consumption | Total content of calcium and magnesium (total hardness) Range (50 − 600) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 5 | Water intended for human consumption | Colour Range (5 – 70) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C | |
| 6 | Water intended for human consumption | Taste threshold number TFN Range 1 |
Simplified method, paired, non-forced choice | PN-EN 1622:2006 | |
| 7 | Water intended for human consumption | Odour threshold number TON Range 1 |
Simplified method, paired, non-forced choice | PN-EN 1622:2006 | |
| 8 | Water, Water intended for human consumption | Anion concentrations nitrites (0,15 – 5,0) mg/l chlorides (5,0 – 250) mg/l sulfates (5,0 – 250) mg/l fluorides (0,10 – 10) mg/l bromides (0,10 – 10) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 9 | Water, Water intended for human consumption | Total viable count at 22°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 10 | Water, Water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 11 | Water, Water intended for human consumption | Most probable number, Escherichia coli | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 12 | Water, Water intended for human consumption | Most probable number of coliform bacteria | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 13 | Water, Water intended for human consumption | Clostridium perfringens count (including spores) | Membrane filtration method | PN-EN ISO 14189:2016-10 | |
| 14 | Water (including bathing water), Water intended for human consumption | Enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 15 | Water (including swimming pool water, bathing water) | Sampling for testing microbiological Temperature Range (5,0 – 50,0) °C |
PN-EN ISO 19458:2007 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r. | ||
| 16 | Water intended for human consumption | Sampling for testing microbiological Temperature Range (5,0 – 70,0) °C |
PN-EN ISO 19458:2007 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r. | ||
| 17 | Swimming pool water, Water intended for human consumption | Turbidity Range (0,08 – 40) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 p. 5.3 | |
| 18 | Swimming pool water, Water intended for human consumption | Free chlorine concentration Range (0,030 – 5,00) mg/l |
Spectrophotometric method | PN-EN ISO 7393-2:2018-04 | |
| 19 | Swimming pool water, Water intended for human consumption | Permanganate index Range (0,50 – 10,0) mg/l O2 |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 20 | Water (including swimming pool water), Water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 21 | Water (including swimming pool water), Water intended for human consumption | Coagulase-positive staphylococci count | Membrane filtration method | PN-Z-11001-3:2000 załącznik A z wyłączeniem pkt 5.2.1 z potwierdzeniem aminopeptydazy | |
| 22 | Water (including swimming pool water), Water intended for human consumption | Total viable count at 36°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 23 | Water (including swimming pool water), Water intended for human consumption | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 24 | Water (including swimming pool water), Water intended for human consumption | Legionella count Matrix A: Procedure 5 (medium A-BCYE), Procedure 7 (medium C-GVPC) |
Membrane filtration method | PN-EN ISO 11731:2017-08 + Ap1:2019-12 | |
| 25 | Water (including swimming pool water), Water intended for human consumption | Nitrate concentration Range (2,0 – 100) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 26 | Water (including swimming pool water), Water intended for human consumption, Wastewater | pH Range 4,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 27 | Water, Water intended for human consumption, Wastewater | Electrical conductivity Range (147 – 2770) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 28 | Water, Water intended for human consumption, Wastewater | Nitrite concentration Range (0,0070 – 32,9) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 29 | Water, Water intended for human consumption, Wastewater | Nitrite nitrogen concentration Range (0,0020 – 10,0) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 30 | Water, Water intended for human consumption, Wastewater | Total iron concentration Range (20 – 10 000) μg/l |
Spectrophotometric method | PN-ISO 6332:2001 +Ap1:2016-06 | |
| 31 | Water, Water intended for human consumption, Wastewater | Ammonium nitrogen concentration Range (0,050 – 200) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 32 | Water, Water intended for human consumption, Wastewater | Ammonium ion concentration Range (0,060 – 258) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 33 | Wastewater | Sampling for chemical and physical testing Temperature Range (5,0 – 50,0) °C |
Manual and automatic method | PN-ISO 5667-10:2021-11 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r. | |
| 34 | Wastewater | Anion concentrations nitrite nitrogen (0,046 – 50) mg/l nitrate nitrogen (0,46 – 50) mg/l chlorides (5,0 – 2000) mg/l sulfates (5,0 – 500) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 35 | Wastewater | Total nitrogen concentration Range (2,0 – 200) mg/l |
Spectrophotometric method | PB-LS-07 wydanie 03 z dnia 03.06.2019 r. | na podstawie testu kuwetowego Hach-Lange Nr LCK138, LCK238, LCK338 | |
| 36 | Wastewater | Concentration of substances extractable with petroleum ether Range (5 – 500) mg/l |
Gravimetric method | PB-LS-02 wydanie 03 z dnia 03.06.2019 r. | |
| 37 | Swimming pool water | Sampling for chemical and physical testing | IOL-07 wyd. 01 z dnia 28.02.2020 | ||
| 38 | Swimming pool water | Oxidation-reduction (redox) potential vs. Ag/AgCl 3,5 mol/l KCl Range (200 – 850) mV |
Potentiometric method | PB-FCH-03 wyd. 01 z dnia 02.01.2020 | |
| 39 | Swimming pool water | Total chlorine concentration Range (0,030 – 5,00) mg/l |
Spectrophotometric method | PN-EN ISO 7393-2:2018-04 | |
| 40 | Swimming pool water | Combined chlorine concentration (calculated) | PB-FCH-06 wydanie 04 z dnia 10.04.2019 r. | ||
| 41 | Water, Wastewater | Biochemical oxygen demand BOD5 Range (1,5 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 42 | Water, Wastewater | Biochemical oxygen demand BOD5 Range (3 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 43 | Water, Wastewater | Total suspended solids (TSS) Range (2,0– 2000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 44 | Water, Wastewater | Chemical oxygen demand – COD-Cr Range (5,00 – 10000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 45 | Water, Wastewater | Total phosphorus concentration Range (0,040 – 40,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010 | |
| 46 | Water, Wastewater | Sum of chlorides and sulphates (calculated) | PB-LS-16 wydanie 03 z dnia 18.04.2023 r. | ||
| 47 | Water, Wastewater | Kjeldahl nitrogen concentration Range (2,00 – 200) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 48 | Water, Wastewater | Total nitrogen concentration (calculated) | PB-LS-15 wydanie 02 z dnia 18.04.2019 r. | ||
Reference standards (40)
IOL-07 wyd. 01 z dnia 28.02.2020
PB-FCH-02 wydanie 05 z dnia 03.06.2019 r. na podstawie testu Hach-Lange Nr 8149
PB-FCH-03 wyd. 01 z dnia 02.01.2020
PB-FCH-06 wydanie 04 z dnia 10.04.2019 r.
PB-LS-02 wydanie 03 z dnia 03.06.2019 r.
PB-LS-07 wydanie 03 z dnia 03.06.2019 r.
PB-LS-12 wydanie 04 z dnia 10.04.2026 r.
PB-LS-15 wydanie 02 z dnia 18.04.2019 r.
PB-LS-16 wydanie 03 z dnia 18.04.2023 r.
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 + Ap1:2019-12
PN-EN ISO 14189:2016-10
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09 p. 5.3
PN-EN ISO 7393-2:2018-04
PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001 +Ap1:2016-06
PN-ISO 7150-1:2002
PN-Z-11001-3:2000 załącznik A z wyłączeniem pkt 5.2.1 z potwierdzeniem aminopeptydazy
na podstawie testu kuwetowego Hach-Lange Nr LCK138, LCK238, LCK338