🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI PL

PCA AB 1099 • Ostróda, Poland • 48 methods

Water & wastewaterMicrobiology

PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI is a laboratory accredited by PCA under number AB 1099 (Ostróda, Poland). Its accreditation scope covers 48 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Wastewater, Water intended for human consumption, Water (including swimming pool water), Water intended for human con…, Water, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Ion chromatography with conductometric detection (IC-CD).

At a glance

  • Accreditation number: PCA AB 1099
  • Methods in scope: 48
  • Types of test objects: 12
  • Techniques used: 14
  • City: Ostróda, Poland
Accreditation number
AB 1099
Accreditation body
PCA
Address
OSTRÓDA Sp. z o.o., Tyrowo 104, 14-100 Ostróda, LABORATORIUM ANALIZY WODY I ŚCIEKÓW
City
Ostróda, Poland

What this laboratory tests (12)

Analytical techniques used (14)

Laboratory locations

Accreditation scope — test methods (48)

No. Test object Methodology / Parameters Technique Reference document
Water and Wastewater Analysis Laboratory
1 Water Sampling for chemical and physical testing
Temperature Range (5,0 – 50,0) °C
Automatic method; Manual method PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.
2 Water intended for human consumption Sampling for chemical and physical testing (including sensory testing)
Temperature Range (5,0 – 50,0) °C
PN-ISO 5667-5:2017-10 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.
3 Water intended for human consumption Manganese concentration
Range (15,0 – 700) μg/l
Spectrophotometric method PB-FCH-02 wydanie 05 z dnia 03.06.2019 r. na podstawie testu Hach-Lange Nr 8149
4 Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (50 − 600) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
5 Water intended for human consumption Colour
Range (5 – 70) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C
6 Water intended for human consumption Taste threshold number TFN
Range 1
Simplified method, paired, non-forced choice PN-EN 1622:2006
7 Water intended for human consumption Odour threshold number TON
Range 1
Simplified method, paired, non-forced choice PN-EN 1622:2006
8 Water, Water intended for human consumption Anion concentrations
nitrites (0,15 – 5,0) mg/l chlorides (5,0 – 250) mg/l sulfates (5,0 – 250) mg/l fluorides (0,10 – 10) mg/l bromides (0,10 – 10) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
9 Water, Water intended for human consumption Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004
10 Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
11 Water, Water intended for human consumption Most probable number, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06
12 Water, Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
13 Water, Water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10
14 Water (including bathing water), Water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
15 Water (including swimming pool water, bathing water) Sampling for testing
microbiological Temperature Range (5,0 – 50,0) °C
PN-EN ISO 19458:2007 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.
16 Water intended for human consumption Sampling for testing
microbiological Temperature Range (5,0 – 70,0) °C
PN-EN ISO 19458:2007 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.
17 Swimming pool water, Water intended for human consumption Turbidity
Range (0,08 – 40) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09 p. 5.3
18 Swimming pool water, Water intended for human consumption Free chlorine concentration
Range (0,030 – 5,00) mg/l
Spectrophotometric method PN-EN ISO 7393-2:2018-04
19 Swimming pool water, Water intended for human consumption Permanganate index
Range (0,50 – 10,0) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
20 Water (including swimming pool water), Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
21 Water (including swimming pool water), Water intended for human consumption Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3:2000 załącznik A z wyłączeniem pkt 5.2.1 z potwierdzeniem aminopeptydazy
22 Water (including swimming pool water), Water intended for human consumption Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004
23 Water (including swimming pool water), Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
24 Water (including swimming pool water), Water intended for human consumption Legionella count
Matrix A: Procedure 5 (medium A-BCYE), Procedure 7 (medium C-GVPC)
Membrane filtration method PN-EN ISO 11731:2017-08 + Ap1:2019-12
25 Water (including swimming pool water), Water intended for human consumption Nitrate concentration
Range (2,0 – 100) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
26 Water (including swimming pool water), Water intended for human consumption, Wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
27 Water, Water intended for human consumption, Wastewater Electrical conductivity
Range (147 – 2770) μS/cm
Conductometric method PN-EN 27888:1999
28 Water, Water intended for human consumption, Wastewater Nitrite concentration
Range (0,0070 – 32,9) mg/l
Spectrophotometric method PN-EN 26777:1999
29 Water, Water intended for human consumption, Wastewater Nitrite nitrogen concentration
Range (0,0020 – 10,0) mg/l
Spectrophotometric method PN-EN 26777:1999
30 Water, Water intended for human consumption, Wastewater Total iron concentration
Range (20 – 10 000) μg/l
Spectrophotometric method PN-ISO 6332:2001 +Ap1:2016-06
31 Water, Water intended for human consumption, Wastewater Ammonium nitrogen concentration
Range (0,050 – 200) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
32 Water, Water intended for human consumption, Wastewater Ammonium ion concentration
Range (0,060 – 258) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
33 Wastewater Sampling for chemical and physical testing
Temperature Range (5,0 – 50,0) °C
Manual and automatic method PN-ISO 5667-10:2021-11 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.
34 Wastewater Anion concentrations
nitrite nitrogen (0,046 – 50) mg/l nitrate nitrogen (0,46 – 50) mg/l chlorides (5,0 – 2000) mg/l sulfates (5,0 – 500) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
35 Wastewater Total nitrogen concentration
Range (2,0 – 200) mg/l
Spectrophotometric method PB-LS-07 wydanie 03 z dnia 03.06.2019 r. | na podstawie testu kuwetowego Hach-Lange Nr LCK138, LCK238, LCK338
36 Wastewater Concentration of substances extractable with petroleum ether
Range (5 – 500) mg/l
Gravimetric method PB-LS-02 wydanie 03 z dnia 03.06.2019 r.
37 Swimming pool water Sampling for chemical and physical testing IOL-07 wyd. 01 z dnia 28.02.2020
38 Swimming pool water Oxidation-reduction (redox) potential vs. Ag/AgCl 3,5 mol/l KCl
Range (200 – 850) mV
Potentiometric method PB-FCH-03 wyd. 01 z dnia 02.01.2020
39 Swimming pool water Total chlorine concentration
Range (0,030 – 5,00) mg/l
Spectrophotometric method PN-EN ISO 7393-2:2018-04
40 Swimming pool water Combined chlorine concentration (calculated) PB-FCH-06 wydanie 04 z dnia 10.04.2019 r.
41 Water, Wastewater Biochemical oxygen demand
BOD5 Range (1,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
42 Water, Wastewater Biochemical oxygen demand
BOD5 Range (3 – 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
43 Water, Wastewater Total suspended solids (TSS)
Range (2,0– 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
44 Water, Wastewater Chemical oxygen demand – COD-Cr
Range (5,00 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
45 Water, Wastewater Total phosphorus concentration
Range (0,040 – 40,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010
46 Water, Wastewater Sum of chlorides and sulphates (calculated) PB-LS-16 wydanie 03 z dnia 18.04.2023 r.
47 Water, Wastewater Kjeldahl nitrogen concentration
Range (2,00 – 200) mg/l
Titrimetric method PN-EN 25663:2001
48 Water, Wastewater Total nitrogen concentration (calculated) PB-LS-15 wydanie 02 z dnia 18.04.2019 r.

Reference standards (40)

IOL-07 wyd. 01 z dnia 28.02.2020
PB-FCH-02 wydanie 05 z dnia 03.06.2019 r. na podstawie testu Hach-Lange Nr 8149
PB-FCH-03 wyd. 01 z dnia 02.01.2020
PB-FCH-06 wydanie 04 z dnia 10.04.2019 r.
PB-LS-02 wydanie 03 z dnia 03.06.2019 r.
PB-LS-07 wydanie 03 z dnia 03.06.2019 r.
PB-LS-12 wydanie 04 z dnia 10.04.2026 r.
PB-LS-15 wydanie 02 z dnia 18.04.2019 r.
PB-LS-16 wydanie 03 z dnia 18.04.2023 r.
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 + Ap1:2019-12
PN-EN ISO 14189:2016-10
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09 p. 5.3
PN-EN ISO 7393-2:2018-04
PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001 +Ap1:2016-06
PN-ISO 7150-1:2002
PN-Z-11001-3:2000 załącznik A z wyłączeniem pkt 5.2.1 z potwierdzeniem aminopeptydazy
na podstawie testu kuwetowego Hach-Lange Nr LCK138, LCK238, LCK338