{"lab":{"_id":"69ad52a3de79e566650fb598","accr_number":"AB 1099","country":"PL","accr_body":"PCA","address":"OSTRÓDA Sp. z o.o., Tyrowo 104, 14-100 Ostróda, LABORATORIUM ANALIZY WODY I ŚCIEKÓW","categories":["water","microbiology"],"city":"Ostróda","imported_at":"2026-03-08T10:42:43.265Z","methods_count":48,"name":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1099.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo wodociągów i kanalizacji ostróda sp. z o.o., tyrowo 104, 14-100 ostróda, laboratorium analizy wody i ścieków water other microbiology automotive pharma electronics","status":"active","updated_at":"2026-03-08T14:50:17.003Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:57:05.305Z","parse_date":"2026-08-13T07:57:05.305Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://www.bip.pwik.ostroda.pl/155,laboratorium","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"},{"codes":"Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody do spożycia przez ludzi","en":"Sensory tests and sampling of drinking water"}],"issue":{"no":"23","date":"10.07.2026"},"map_coord":[53.702853,19.962303],"map_geo":"nominatim-city","lab_locations":[{"name":"LABORATORIUM ANALIZY WODY I ŚCIEKÓW","address":"AB 1099 ul. 21 Stycznia 34","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/879196f73bfc01100a115005667fc26a/AB%201099.pdf","has_en":true,"category_counts":{"water":48,"microbiology":7},"category_scores":{"water":41.89,"microbiology":0.89},"has_zh":true},"methods":[{"_id":"6a7d78d10636ba417e41a2f7","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(5,0 – 50,0) °C"}],"technique":"Metoda automatyczna; Metoda manualna","techniques":["Metoda automatyczna","Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (5,0 – 50,0) °C\nMetoda automatyczna; Metoda manualna","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6","PB-LS-12 wydanie 04 z dnia 10.04.2026 r."],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (5,0 – 50,0) °C\nMetoda automatyczna; Metoda manualna PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r. Woda Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (5,0 – 50,0) °C\nMetoda automatyczna; Metoda manualna PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.2, 7.3, 7.5, 7.6 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(5,0 – 50,0) °C"}],"search_en":"Water Sampling for chemical and physical testing Automatic method; Manual method Water and Wastewater Analysis Laboratory Temperature Range PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","technique_en":"Automatic method; Manual method","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(5,0 – 50,0) °C"}],"search_zh":"水 化学与物理检测用样品采集 自动法；手工法 水与废水分析实验室 温度 范围 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2, 7.3, 7.5, 7.6 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","test_object_zh":"水","lab_section_zh":"水与废水分析实验室","technique_zh":"自动法；手工法"},{"_id":"6a7d78d10636ba417e41a2f8","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(5,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)\nZakres:\nTemperatura\nZakres (5,0 – 50,0) °C","reference":"PN-ISO 5667-5:2017-10 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","norm_bases":["PN-ISO 5667-5:2017-10","PB-LS-12 wydanie 04 z dnia 10.04.2026 r."],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)\nZakres:\nTemperatura\nZakres (5,0 – 50,0) °C PN-ISO 5667-5:2017-10 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r. Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych (w tym sensorycznych)\nZakres:\nTemperatura\nZakres (5,0 – 50,0) °C PN-ISO 5667-5:2017-10 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Sampling for chemical and physical testing (including sensory testing)","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(5,0 – 50,0) °C"}],"search_en":"Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) Water and Wastewater Analysis Laboratory Temperature Range PN-ISO 5667-5:2017-10 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(5,0 – 50,0) °C"}],"search_zh":"生活饮用水 化学和物理检测采样（含感官检测） 水与废水分析实验室 温度 范围 PN-ISO 5667-5:2017-10 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","test_object_zh":"生活饮用水","lab_section_zh":"水与废水分析实验室","methodology_zh":"化学和物理检测采样（含感官检测）"},{"_id":"6a7d78d10636ba417e41a2f9","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(15,0 – 700) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (15,0 – 700) μg/l\nMetoda spektrofotometryczna","reference":"PB-FCH-02 wydanie 05 z dnia 03.06.2019 r. na podstawie testu Hach-Lange Nr 8149","norm_bases":["PB-FCH-02 wydanie 05 z dnia 03.06.2019 r. na podstawie testu Hach-Lange Nr 8149"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (15,0 – 700) μg/l\nMetoda spektrofotometryczna PB-FCH-02 wydanie 05 z dnia 03.06.2019 r. na podstawie testu Hach-Lange Nr 8149 Woda do spozycia przez ludzi Stezenie manganu\nZakres (15,0 – 700) μg/l\nMetoda spektrofotometryczna PB-FCH-02 wydanie 05 z dnia 03.06.2019 r. na podstawie testu Hach-Lange Nr 8149","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(15,0 – 700) μg/l"}],"search_en":"Water intended for human consumption Manganese concentration Spectrophotometric method Water and Wastewater Analysis Laboratory Range PB-FCH-02 wydanie 05 z dnia 03.06.2019 r. na podstawie testu Hach-Lange Nr 8149","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(15,0 – 700) μg/l"}],"search_zh":"生活饮用水 锰浓度 分光光度法 水与废水分析实验室 范围 PB-FCH-02 wydanie 05 z dnia 03.06.2019 r. na podstawie testu Hach-Lange Nr 8149","technique_zh":"分光光度法","test_object_zh":"生活饮用水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a2fa","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(50 − 600) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (50 − 600) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (50 − 600) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (50 − 600) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(50 − 600) mg/l CaCO3"}],"search_en":"Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Water and Wastewater Analysis Laboratory Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(50 − 600) mg/l CaCO3"}],"search_zh":"生活饮用水 钙与镁总量（总硬度） 滴定法 水与废水分析实验室 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a2fb","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 70) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5 – 70) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C Woda do spozycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 70) mg/l Pt"}],"search_en":"Water intended for human consumption Colour Spectrophotometric method Water and Wastewater Analysis Laboratory Range PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/l Pt"}],"search_zh":"生活饮用水 色度 分光光度法 水与废水分析实验室 范围 PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","technique_zh":"分光光度法","test_object_zh":"生活饮用水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a2fc","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa smaku TFN","parameters":[{"name":"Zakres","range":"1"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa smaku TFN\nZakres 1\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Taste threshold number TFN","parameters_en":[{"name":"Range","range":"1"}],"search_en":"Water intended for human consumption Taste threshold number TFN Simplified method, paired, non-forced choice Water and Wastewater Analysis Laboratory Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"1"}],"search_zh":"生活饮用水 味阈值 TFN 简化法，成对，非强制选择 水与废水分析实验室 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","technique_zh":"简化法，成对，非强制选择","lab_section_zh":"水与废水分析实验室","methodology_zh":"味阈值 TFN"},{"_id":"6a7d78d10636ba417e41a2fd","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa zapachu TON","parameters":[{"name":"Zakres","range":"1"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa zapachu TON\nZakres 1\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Odour threshold number TON","parameters_en":[{"name":"Range","range":"1"}],"search_en":"Water intended for human consumption Odour threshold number TON Simplified method, paired, non-forced choice Water and Wastewater Analysis Laboratory Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"1"}],"search_zh":"生活饮用水 嗅阈值 TON 简化法，成对，非强制选择 水与废水分析实验室 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","technique_zh":"简化法，成对，非强制选择","lab_section_zh":"水与废水分析实验室","methodology_zh":"嗅阈值 TON"},{"_id":"6a7d78d10636ba417e41a2fe","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie anionów","parameters":[{"name":"azotyny","range":"(0,15 – 5,0) mg/l"},{"name":"chlorki","range":"(5,0 – 250) mg/l"},{"name":"siarczany","range":"(5,0 – 250) mg/l"},{"name":"fluorki","range":"(0,10 – 10) mg/l"},{"name":"bromki","range":"(0,10 – 10) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nazotyny (0,15 – 5,0) mg/l\nchlorki (5,0 – 250) mg/l\nsiarczany (5,0 – 250) mg/l\nfluorki (0,10 – 10) mg/l\nbromki (0,10 – 10) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie anionów\nZakres:\nazotyny (0,15 – 5,0) mg/l\nchlorki (5,0 – 250) mg/l\nsiarczany (5,0 – 250) mg/l\nfluorki (0,10 – 10) mg/l\nbromki (0,10 – 10) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, Woda do spozycia przez ludzi Stezenie anionow\nZakres:\nazotyny (0,15 – 5,0) mg/l\nchlorki (5,0 – 250) mg/l\nsiarczany (5,0 – 250) mg/l\nfluorki (0,10 – 10) mg/l\nbromki (0,10 – 10) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Anion concentrations","parameters_en":[{"name":"nitrites","range":"(0,15 – 5,0) mg/l"},{"name":"chlorides","range":"(5,0 – 250) mg/l"},{"name":"sulfates","range":"(5,0 – 250) mg/l"},{"name":"fluorides","range":"(0,10 – 10) mg/l"},{"name":"bromides","range":"(0,10 – 10) mg/l"}],"search_en":"Water, Water intended for human consumption Anion concentrations Ion chromatography with conductometric detection (IC-CD) Water and Wastewater Analysis Laboratory nitrites chlorides sulfates fluorides bromides PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, Water intended for human consumption","methodology_zh":"阴离子浓度","search_zh":"水、生活饮用水 阴离子浓度 离子色谱-电导检测法（IC-CD） 水与废水分析实验室 亚硝酸盐 氯化物 硫酸盐 氟化物 溴化物 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"亚硝酸盐","range":"(0,15 – 5,0) mg/l"},{"name":"氯化物","range":"(5,0 – 250) mg/l"},{"name":"硫酸盐","range":"(5,0 – 250) mg/l"},{"name":"氟化物","range":"(0,10 – 10) mg/l"},{"name":"溴化物","range":"(0,10 – 10) mg/l"}],"lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a2ff","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Total viable count at 22°C","search_en":"Water, Water intended for human consumption Total viable count at 22°C Plate method (pour plate) Water and Wastewater Analysis Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","methodology_zh":"22°C 微生物总数","search_zh":"水、生活饮用水 22°C 微生物总数 平板法（倾注培养） 水与废水分析实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a300","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Coliform bacteria count","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method Water and Wastewater Analysis Laboratory PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 水与废水分析实验室 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a301","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Most probable number, Escherichia coli","search_en":"Water, Water intended for human consumption Most probable number, Escherichia coli MPN method Water and Wastewater Analysis Laboratory PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） 最可能数法（MPN） 水与废水分析实验室 PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a302","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Most probable number of coliform bacteria","search_en":"Water, Water intended for human consumption Most probable number of coliform bacteria MPN method Water and Wastewater Analysis Laboratory PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"水、生活饮用水 大肠菌群最可能数（MPN） 最可能数法（MPN） 水与废水分析实验室 PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a303","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Clostridium perfringens (łącznie z przetrwalnikami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens (łącznie z przetrwalnikami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Clostridium perfringens (łącznie z przetrwalnikami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda, Woda do spozycia przez ludzi Liczba Clostridium perfringens (lacznie z przetrwalnikami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Clostridium perfringens count (including spores)","search_en":"Water, Water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method Water and Wastewater Analysis Laboratory PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 产气荚膜梭菌数（含芽孢） 膜过滤法 水与废水分析实验室 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_zh":"水与废水分析实验室","methodology_zh":"产气荚膜梭菌数（含芽孢）"},{"_id":"6a7d78d10636ba417e41a304","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda (w tym woda z kąpielisk), Woda do spożycia przez ludzi","methodology":"Liczba enterokoków","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda z kąpielisk), Woda do spożycia przez ludzi Liczba enterokoków\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda (w tym woda z kapielisk), Woda do spozycia przez ludzi Liczba enterokokow\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Enterococci count","search_en":"Water (including bathing water), Water intended for human consumption Enterococci count Membrane filtration method Water and Wastewater Analysis Laboratory PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water (including bathing water), Water intended for human consumption","methodology_zh":"肠球菌计数","search_zh":"肠球菌计数 膜过滤法 水与废水分析实验室 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a305","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach, woda z kąpielisk)","methodology":"Pobieranie próbek do badań","parameters":[{"name":"mikrobiologicznych"},{"name":"Temperatura"},{"name":"Zakres","range":"(5,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań\nZakres:\nmikrobiologicznych\nTemperatura\nZakres (5,0 – 50,0) °C","reference":"PN-EN ISO 19458:2007 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","norm_bases":["PN-EN ISO 19458:2007","PB-LS-12 wydanie 04 z dnia 10.04.2026 r."],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach, woda z kąpielisk) Pobieranie próbek do badań\nZakres:\nmikrobiologicznych\nTemperatura\nZakres (5,0 – 50,0) °C PN-EN ISO 19458:2007 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r. Woda (w tym woda na plywalniach, woda z kapielisk) Pobieranie probek do badan\nZakres:\nmikrobiologicznych\nTemperatura\nZakres (5,0 – 50,0) °C PN-EN ISO 19458:2007 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","categories":["water","microbiology"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Sampling for testing","parameters_en":[{"name":"microbiological"},{"name":"Temperature"},{"name":"Range","range":"(5,0 – 50,0) °C"}],"search_en":"Water (including swimming pool water, bathing water) Sampling for testing Water and Wastewater Analysis Laboratory microbiological Temperature Range PN-EN ISO 19458:2007 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","test_object_en":"Water (including swimming pool water, bathing water)","parameters_zh":[{"name":"微生物学的"},{"name":"温度"},{"name":"范围","range":"(5,0 – 50,0) °C"}],"search_zh":"检测采样 水与废水分析实验室 微生物学的 温度 范围 PN-EN ISO 19458:2007 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","lab_section_zh":"水与废水分析实验室","methodology_zh":"检测采样"},{"_id":"6a7d78d10636ba417e41a306","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań","parameters":[{"name":"mikrobiologicznych"},{"name":"Temperatura"},{"name":"Zakres","range":"(5,0 – 70,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań\nZakres:\nmikrobiologicznych\nTemperatura\nZakres (5,0 – 70,0) °C","reference":"PN-EN ISO 19458:2007 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","norm_bases":["PN-EN ISO 19458:2007","PB-LS-12 wydanie 04 z dnia 10.04.2026 r."],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań\nZakres:\nmikrobiologicznych\nTemperatura\nZakres (5,0 – 70,0) °C PN-EN ISO 19458:2007 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r. Woda do spozycia przez ludzi Pobieranie probek do badan\nZakres:\nmikrobiologicznych\nTemperatura\nZakres (5,0 – 70,0) °C PN-EN ISO 19458:2007 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","categories":["water","microbiology"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Sampling for testing","parameters_en":[{"name":"microbiological"},{"name":"Temperature"},{"name":"Range","range":"(5,0 – 70,0) °C"}],"search_en":"Water intended for human consumption Sampling for testing Water and Wastewater Analysis Laboratory microbiological Temperature Range PN-EN ISO 19458:2007 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"微生物学的"},{"name":"温度"},{"name":"范围","range":"(5,0 – 70,0) °C"}],"search_zh":"生活饮用水 检测采样 水与废水分析实验室 微生物学的 温度 范围 PN-EN ISO 19458:2007 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","test_object_zh":"生活饮用水","lab_section_zh":"水与废水分析实验室","methodology_zh":"检测采样"},{"_id":"6a7d78d10636ba417e41a307","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda na pływalniach, Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,08 – 40) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,08 – 40) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09 p. 5.3","norm_bases":["PN-EN ISO 7027-1:2016-09 p. 5.3"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach, Woda do spożycia przez ludzi Mętność\nZakres (0,08 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 p. 5.3 Woda na plywalniach, Woda do spozycia przez ludzi Metnosc\nZakres (0,08 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 p. 5.3","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,08 – 40) NTU"}],"search_en":"Swimming pool water, Water intended for human consumption Turbidity Nephelometric method Water and Wastewater Analysis Laboratory Range PN-EN ISO 7027-1:2016-09 p. 5.3","technique_en":"Nephelometric method","test_object_en":"Swimming pool water, Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,08 – 40) NTU"}],"search_zh":"游泳池水、生活饮用水 浊度 浊度法（散射法） 水与废水分析实验室 范围 PN-EN ISO 7027-1:2016-09 p. 5.3","technique_zh":"浊度法（散射法）","lab_section_zh":"水与废水分析实验室","test_object_zh":"游泳池水、生活饮用水"},{"_id":"6a7d78d10636ba417e41a308","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda na pływalniach, Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,030 – 5,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,030 – 5,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach, Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,030 – 5,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda na plywalniach, Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,030 – 5,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,030 – 5,00) mg/l"}],"search_en":"Swimming pool water, Water intended for human consumption Free chlorine concentration Spectrophotometric method Water and Wastewater Analysis Laboratory Range PN-EN ISO 7393-2:2018-04","technique_en":"Spectrophotometric method","test_object_en":"Swimming pool water, Water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,030 – 5,00) mg/l"}],"search_zh":"游泳池水、生活饮用水 游离氯浓度 分光光度法 水与废水分析实验室 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"分光光度法","lab_section_zh":"水与废水分析实验室","test_object_zh":"游泳池水、生活饮用水"},{"_id":"6a7d78d10636ba417e41a309","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda na pływalniach, Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 – 10,0) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 10,0) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach, Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 10,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda na plywalniach, Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 10,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 – 10,0) mg/l O2"}],"search_en":"Swimming pool water, Water intended for human consumption Permanganate index Titrimetric method Water and Wastewater Analysis Laboratory Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Swimming pool water, Water intended for human consumption","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 10,0) mg/l O2"}],"search_zh":"游泳池水、生活饮用水 高锰酸盐指数 滴定法 水与废水分析实验室 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","lab_section_zh":"水与废水分析实验室","test_object_zh":"游泳池水、生活饮用水"},{"_id":"6a7d78d10636ba417e41a30a","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Escherichia coli count","search_en":"Water (including swimming pool water), Water intended for human consumption Escherichia coli count Membrane filtration method Water and Wastewater Analysis Laboratory PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水（含游泳池水）、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 水与废水分析实验室 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a30b","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Liczba gronkowców koagulazo-dodatnich","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej","reference":"PN-Z-11001-3:2000 załącznik A z wyłączeniem pkt 5.2.1 z potwierdzeniem aminopeptydazy","norm_bases":["PN-Z-11001-3:2000 załącznik A z wyłączeniem pkt 5.2.1 z potwierdzeniem aminopeptydazy"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej PN-Z-11001-3:2000 załącznik A z wyłączeniem pkt 5.2.1 z potwierdzeniem aminopeptydazy Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Liczba gronkowcow koagulazo-dodatnich\nMetoda filtracji membranowej PN-Z-11001-3:2000 zalacznik A z wylaczeniem pkt 5.2.1 z potwierdzeniem aminopeptydazy","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Coagulase-positive staphylococci count","search_en":"Water (including swimming pool water), Water intended for human consumption Coagulase-positive staphylococci count Membrane filtration method Water and Wastewater Analysis Laboratory PN-Z-11001-3:2000 załącznik A z wyłączeniem pkt 5.2.1 z potwierdzeniem aminopeptydazy","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 凝固酶阳性葡萄球菌计数 膜过滤法 水与废水分析实验室 PN-Z-11001-3:2000 załącznik A z wyłączeniem pkt 5.2.1 z potwierdzeniem aminopeptydazy","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水","lab_section_zh":"水与废水分析实验室","methodology_zh":"凝固酶阳性葡萄球菌计数"},{"_id":"6a7d78d10636ba417e41a30c","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Total viable count at 36°C","search_en":"Water (including swimming pool water), Water intended for human consumption Total viable count at 36°C Plate method (pour plate) Water and Wastewater Analysis Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology_zh":"36°C 微生物总数","search_zh":"水（含游泳池水）、生活饮用水 36°C 微生物总数 平板法（倾注培养） 水与废水分析实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）、生活饮用水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a30d","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water (including swimming pool water), Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method Water and Wastewater Analysis Laboratory PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology_zh":"铜绿假单胞菌计数","search_zh":"水（含游泳池水）、生活饮用水 铜绿假单胞菌计数 膜过滤法 水与废水分析实验室 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a30e","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Liczba Legionella","parameters":[{"name":"Matryca A: Procedura 5 (pożywka A-BCYE), Procedura 7 (pożywka C-GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Legionella\nMatryca A: Procedura 5 (pożywka A-BCYE), Procedura 7 (pożywka C-GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 + Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 + Ap1:2019-12"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Liczba Legionella\nMatryca A: Procedura 5 (pożywka A-BCYE), Procedura 7 (pożywka C-GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 + Ap1:2019-12 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Liczba Legionella\nMatryca A: Procedura 5 (pozywka A-BCYE), Procedura 7 (pozywka C-GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 + Ap1:2019-12","categories":["microbiology","water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Legionella count","parameters_en":[{"name":"Matrix A: Procedure 5 (medium A-BCYE), Procedure 7 (medium C-GVPC)"}],"search_en":"Water (including swimming pool water), Water intended for human consumption Legionella count Membrane filtration method Water and Wastewater Analysis Laboratory Matrix A: Procedure 5 (medium A-BCYE), Procedure 7 (medium C-GVPC) PN-EN ISO 11731:2017-08 + Ap1:2019-12","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water), Water intended for human consumption","search_zh":"水（含游泳池水）、生活饮用水 膜过滤法 水与废水分析实验室 PN-EN ISO 11731:2017-08 + Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a30f","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(2,0 – 100) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie azotanów\nZakres (2,0 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi Stężenie azotanów\nZakres (2,0 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi Stezenie azotanow\nZakres (2,0 – 100) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(2,0 – 100) mg/l"}],"search_en":"Water (including swimming pool water), Water intended for human consumption Nitrate concentration Ion chromatography with conductometric detection (IC-CD) Water and Wastewater Analysis Laboratory Range PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water (including swimming pool water), Water intended for human consumption","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 100) mg/l"}],"search_zh":"水（含游泳池水）、生活饮用水 硝酸盐浓度 离子色谱-电导检测法（IC-CD） 水与废水分析实验室 范围 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水（含游泳池水）、生活饮用水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a310","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia przez ludzi, Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda (w tym woda na plywalniach), Woda do spozycia przez ludzi, Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water (including swimming pool water), Water intended for human consumption, Wastewater pH Potentiometric method Water and Wastewater Analysis Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water (including swimming pool water), Water intended for human consumption, Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水（含游泳池水）、生活饮用水、废水 pH 值 电位法 水与废水分析实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","lab_section_zh":"水与废水分析实验室","test_object_zh":"水（含游泳池水）、生活饮用水、废水"},{"_id":"6a7d78d10636ba417e41a311","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(147 – 2770) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (147 – 2770) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Przewodność elektryczna właściwa\nZakres (147 – 2770) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi, Scieki Przewodnosc elektryczna wlasciwa\nZakres (147 – 2770) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(147 – 2770) μS/cm"}],"search_en":"Water, Water intended for human consumption, Wastewater Electrical conductivity Conductometric method Water and Wastewater Analysis Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(147 – 2770) μS/cm"}],"search_zh":"水、生活饮用水、废水 电导率 电导法 水与废水分析实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a312","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,0070 – 32,9) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,0070 – 32,9) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotynów\nZakres (0,0070 – 32,9) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotynow\nZakres (0,0070 – 32,9) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,0070 – 32,9) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Nitrite concentration Spectrophotometric method Water and Wastewater Analysis Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,0070 – 32,9) mg/l"}],"search_zh":"水、生活饮用水、废水 亚硝酸盐浓度 分光光度法 水与废水分析实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a313","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,0020 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0020 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu azotynowego\nZakres (0,0020 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu azotynowego\nZakres (0,0020 – 10,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,0020 – 10,0) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Nitrite nitrogen concentration Spectrophotometric method Water and Wastewater Analysis Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0020 – 10,0) mg/l"}],"search_zh":"水、生活饮用水、废水 亚硝态氮浓度 分光光度法 水与废水分析实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a314","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(20 – 10 000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (20 – 10 000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 +Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 +Ap1:2016-06"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie żelaza ogólnego\nZakres (20 – 10 000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 +Ap1:2016-06 Woda, Woda do spozycia przez ludzi, Scieki Stezenie zelaza ogolnego\nZakres (20 – 10 000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 +Ap1:2016-06","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(20 – 10 000) μg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Total iron concentration Spectrophotometric method Water and Wastewater Analysis Laboratory Range PN-ISO 6332:2001 +Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(20 – 10 000) μg/l"}],"search_zh":"水、生活饮用水、废水 总铁浓度 分光光度法 水与废水分析实验室 范围 PN-ISO 6332:2001 +Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a315","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,050 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,050 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu amonowego\nZakres (0,050 – 200) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu amonowego\nZakres (0,050 – 200) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,050 – 200) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Ammonium nitrogen concentration Spectrophotometric method Water and Wastewater Analysis Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 200) mg/l"}],"search_zh":"水、生活饮用水、废水 氨氮浓度 分光光度法 水与废水分析实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a316","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,060 – 258) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,060 – 258) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie jonu amonowego\nZakres (0,060 – 258) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Woda do spozycia przez ludzi, Scieki Stezenie jonu amonowego\nZakres (0,060 – 258) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,060 – 258) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Ammonium ion concentration Spectrophotometric method Water and Wastewater Analysis Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,060 – 258) mg/l"}],"search_zh":"水、生活饮用水、废水 铵离子浓度 分光光度法 水与废水分析实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a317","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(5,0 – 50,0) °C"}],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (5,0 – 50,0) °C\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","norm_bases":["PN-ISO 5667-10:2021-11","PB-LS-12 wydanie 04 z dnia 10.04.2026 r."],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (5,0 – 50,0) °C\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r. Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (5,0 – 50,0) °C\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(5,0 – 50,0) °C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method Water and Wastewater Analysis Laboratory Temperature Range PN-ISO 5667-10:2021-11 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","technique_en":"Manual and automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(5,0 – 50,0) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手工与自动法 水与废水分析实验室 温度 范围 PN-ISO 5667-10:2021-11 | PB-LS-12 wydanie 04 z dnia 10.04.2026 r.","test_object_zh":"污水","lab_section_zh":"水与废水分析实验室","technique_zh":"手工与自动法"},{"_id":"6a7d78d10636ba417e41a318","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie anionów","parameters":[{"name":"azot azotynowy","range":"(0,046 – 50) mg/l"},{"name":"azot azotanowy","range":"(0,46 – 50) mg/l"},{"name":"chlorki","range":"(5,0 – 2000) mg/l"},{"name":"siarczany","range":"(5,0 – 500) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nazot azotynowy (0,046 – 50) mg/l\nazot azotanowy (0,46 – 50) mg/l\nchlorki (5,0 – 2000) mg/l\nsiarczany (5,0 – 500) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie anionów\nZakres:\nazot azotynowy (0,046 – 50) mg/l\nazot azotanowy (0,46 – 50) mg/l\nchlorki (5,0 – 2000) mg/l\nsiarczany (5,0 – 500) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Scieki Stezenie anionow\nZakres:\nazot azotynowy (0,046 – 50) mg/l\nazot azotanowy (0,46 – 50) mg/l\nchlorki (5,0 – 2000) mg/l\nsiarczany (5,0 – 500) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Anion concentrations","parameters_en":[{"name":"nitrite nitrogen","range":"(0,046 – 50) mg/l"},{"name":"nitrate nitrogen","range":"(0,46 – 50) mg/l"},{"name":"chlorides","range":"(5,0 – 2000) mg/l"},{"name":"sulfates","range":"(5,0 – 500) mg/l"}],"search_en":"Wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) Water and Wastewater Analysis Laboratory nitrite nitrogen nitrate nitrogen chlorides sulfates PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Wastewater","methodology_zh":"阴离子浓度","search_zh":"污水 阴离子浓度 离子色谱-电导检测法（IC-CD） 水与废水分析实验室 亚硝酸盐氮 硝酸盐氮 氯化物 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"污水","parameters_zh":[{"name":"亚硝酸盐氮","range":"(0,046 – 50) mg/l"},{"name":"硝酸盐氮","range":"(0,46 – 50) mg/l"},{"name":"氯化物","range":"(5,0 – 2000) mg/l"},{"name":"硫酸盐","range":"(5,0 – 500) mg/l"}],"lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a319","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(2,0 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (2,0 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PB-LS-07 wydanie 03 z dnia 03.06.2019 r. | na podstawie testu kuwetowego Hach-Lange Nr LCK138, LCK238, LCK338","norm_bases":["PB-LS-07 wydanie 03 z dnia 03.06.2019 r.","na podstawie testu kuwetowego Hach-Lange Nr LCK138, LCK238, LCK338"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (2,0 – 200) mg/l\nMetoda spektrofotometryczna PB-LS-07 wydanie 03 z dnia 03.06.2019 r. | na podstawie testu kuwetowego Hach-Lange Nr LCK138, LCK238, LCK338 Scieki Stezenie azotu ogolnego\nZakres (2,0 – 200) mg/l\nMetoda spektrofotometryczna PB-LS-07 wydanie 03 z dnia 03.06.2019 r. | na podstawie testu kuwetowego Hach-Lange Nr LCK138, LCK238, LCK338","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,0 – 200) mg/l"}],"search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Water and Wastewater Analysis Laboratory Range PB-LS-07 wydanie 03 z dnia 03.06.2019 r. | na podstawie testu kuwetowego Hach-Lange Nr LCK138, LCK238, LCK338","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 200) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 水与废水分析实验室 范围 PB-LS-07 wydanie 03 z dnia 03.06.2019 r. | na podstawie testu kuwetowego Hach-Lange Nr LCK138, LCK238, LCK338","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a31a","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(5 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (5 – 500) mg/l\nMetoda wagowa","reference":"PB-LS-02 wydanie 03 z dnia 03.06.2019 r.","norm_bases":["PB-LS-02 wydanie 03 z dnia 03.06.2019 r."],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (5 – 500) mg/l\nMetoda wagowa PB-LS-02 wydanie 03 z dnia 03.06.2019 r. Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (5 – 500) mg/l\nMetoda wagowa PB-LS-02 wydanie 03 z dnia 03.06.2019 r.","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Concentration of substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(5 – 500) mg/l"}],"search_en":"Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Water and Wastewater Analysis Laboratory Range PB-LS-02 wydanie 03 z dnia 03.06.2019 r.","technique_en":"Gravimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(5 – 500) mg/l"}],"search_zh":"污水 石油醚可萃取物浓度 重量法 水与废水分析实验室 范围 PB-LS-02 wydanie 03 z dnia 03.06.2019 r.","technique_zh":"重量法","test_object_zh":"污水","lab_section_zh":"水与废水分析实验室","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a7d78d10636ba417e41a31b","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"IOL-07 wyd. 01 z dnia 28.02.2020","norm_bases":["IOL-07 wyd. 01 z dnia 28.02.2020"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Pobieranie próbek do badań chemicznych i fizycznych IOL-07 wyd. 01 z dnia 28.02.2020 Woda na plywalniach Pobieranie probek do badan chemicznych i fizycznych IOL-07 wyd. 01 z dnia 28.02.2020","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Swimming pool water Sampling for chemical and physical testing Water and Wastewater Analysis Laboratory IOL-07 wyd. 01 z dnia 28.02.2020","test_object_en":"Swimming pool water","methodology_zh":"化学与物理检测用样品采集","search_zh":"游泳池水 化学与物理检测用样品采集 水与废水分析实验室 IOL-07 wyd. 01 z dnia 28.02.2020","test_object_zh":"游泳池水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a31c","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl","parameters":[{"name":"Zakres","range":"(200 – 850) mV"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 – 850) mV\nMetoda potencjometryczna","reference":"PB-FCH-03 wyd. 01 z dnia 02.01.2020","norm_bases":["PB-FCH-03 wyd. 01 z dnia 02.01.2020"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 – 850) mV\nMetoda potencjometryczna PB-FCH-03 wyd. 01 z dnia 02.01.2020 Woda na plywalniach Potencjal utleniajaco-redukujacy (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (200 – 850) mV\nMetoda potencjometryczna PB-FCH-03 wyd. 01 z dnia 02.01.2020","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Oxidation-reduction (redox) potential vs. Ag/AgCl 3,5 mol/l KCl","parameters_en":[{"name":"Range","range":"(200 – 850) mV"}],"search_en":"Swimming pool water Oxidation-reduction (redox) potential vs. Ag/AgCl 3,5 mol/l KCl Potentiometric method Water and Wastewater Analysis Laboratory Range PB-FCH-03 wyd. 01 z dnia 02.01.2020","technique_en":"Potentiometric method","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(200 – 850) mV"}],"search_zh":"游泳池水 氧化还原电位（redoks），相对于 Ag/AgCl 3,5 mol/l KCl 电位法 水与废水分析实验室 范围 PB-FCH-03 wyd. 01 z dnia 02.01.2020","technique_zh":"电位法","test_object_zh":"游泳池水","lab_section_zh":"水与废水分析实验室","methodology_zh":"氧化还原电位（redoks），相对于 Ag/AgCl 3,5 mol/l KCl"},{"_id":"6a7d78d10636ba417e41a31d","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie chloru ogólnego","parameters":[{"name":"Zakres","range":"(0,030 – 5,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru ogólnego\nZakres (0,030 – 5,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie chloru ogólnego\nZakres (0,030 – 5,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda na plywalniach Stezenie chloru ogolnego\nZakres (0,030 – 5,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,030 – 5,00) mg/l"}],"search_en":"Swimming pool water Total chlorine concentration Spectrophotometric method Water and Wastewater Analysis Laboratory Range PN-EN ISO 7393-2:2018-04","technique_en":"Spectrophotometric method","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(0,030 – 5,00) mg/l"}],"search_zh":"游泳池水 总氯浓度 分光光度法 水与废水分析实验室 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"分光光度法","test_object_zh":"游泳池水","methodology_zh":"总氯浓度","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a31e","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie chloru związanego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"PB-FCH-06 wydanie 04 z dnia 10.04.2019 r.","norm_bases":["PB-FCH-06 wydanie 04 z dnia 10.04.2019 r."],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie chloru związanego (z obliczeń) PB-FCH-06 wydanie 04 z dnia 10.04.2019 r. Woda na plywalniach Stezenie chloru zwiazanego (z obliczen) PB-FCH-06 wydanie 04 z dnia 10.04.2019 r.","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Combined chlorine concentration (calculated)","search_en":"Swimming pool water Combined chlorine concentration (calculated) Water and Wastewater Analysis Laboratory PB-FCH-06 wydanie 04 z dnia 10.04.2019 r.","test_object_en":"Swimming pool water","search_zh":"游泳池水 化合氯浓度（计算值） 水与废水分析实验室 PB-FCH-06 wydanie 04 z dnia 10.04.2019 r.","test_object_zh":"游泳池水","methodology_zh":"化合氯浓度（计算值）","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a31f","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1,5 – 6,0) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method Water and Wastewater Analysis Laboratory BOD5 Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1,5 – 6,0) mg/l O2"}],"search_zh":"水、污水 生化需氧量 电化学法 水与废水分析实验室 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、污水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a320","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method Water and Wastewater Analysis Laboratory BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"水、污水 生化需氧量 电化学法 水与废水分析实验室 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、污水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a321","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0– 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0– 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (2,0– 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (2,0– 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0– 2000) mg/l"}],"search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Water and Wastewater Analysis Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0– 2000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 水与废水分析实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a322","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr","parameters":[{"name":"Zakres","range":"(5,00 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (5,00 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (5,00 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu – ChZT-Cr\nZakres (5,00 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Chemical oxygen demand – COD-Cr","parameters_en":[{"name":"Range","range":"(5,00 – 10000) mg/l O2"}],"search_en":"Water, Wastewater Chemical oxygen demand – COD-Cr Spectrophotometric method Water and Wastewater Analysis Laboratory Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(5,00 – 10000) mg/l O2"}],"search_zh":"水、污水 化学需氧量（COD-Cr） 分光光度法 水与废水分析实验室 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","lab_section_zh":"水与废水分析实验室","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a7d78d10636ba417e41a323","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,040 – 40,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,040 – 40,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,040 – 40,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,040 – 40,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,040 – 40,0) mg/l"}],"search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Water and Wastewater Analysis Laboratory Range PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 40,0) mg/l"}],"search_zh":"水、污水 总磷浓度 分光光度法 水与废水分析实验室 范围 PN-EN ISO 6878:2006 pkt. 7 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、污水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a324","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Suma chlorków i siarczanów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma chlorków i siarczanów (z obliczeń)","reference":"PB-LS-16 wydanie 03 z dnia 18.04.2023 r.","norm_bases":["PB-LS-16 wydanie 03 z dnia 18.04.2023 r."],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Suma chlorków i siarczanów (z obliczeń) PB-LS-16 wydanie 03 z dnia 18.04.2023 r. Woda, Scieki Suma chlorkow i siarczanow (z obliczen) PB-LS-16 wydanie 03 z dnia 18.04.2023 r.","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Sum of chlorides and sulphates (calculated)","search_en":"Water, Wastewater Sum of chlorides and sulphates (calculated) Water and Wastewater Analysis Laboratory PB-LS-16 wydanie 03 z dnia 18.04.2023 r.","test_object_en":"Water, Wastewater","search_zh":"水、污水 氯化物与硫酸盐总量（由计算得出） 水与废水分析实验室 PB-LS-16 wydanie 03 z dnia 18.04.2023 r.","test_object_zh":"水、污水","lab_section_zh":"水与废水分析实验室","methodology_zh":"氯化物与硫酸盐总量（由计算得出）"},{"_id":"6a7d78d10636ba417e41a325","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(2,00 – 200) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (2,00 – 200) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (2,00 – 200) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (2,00 – 200) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,00 – 200) mg/l"}],"search_en":"Water, Wastewater Kjeldahl nitrogen concentration Titrimetric method Water and Wastewater Analysis Laboratory Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(2,00 – 200) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 滴定法 水与废水分析实验室 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、污水","lab_section_zh":"水与废水分析实验室"},{"_id":"6a7d78d10636ba417e41a326","lab_id":"69ad52a3de79e566650fb598","country":"PL","accr_number":"AB 1099","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-LS-15 wydanie 02 z dnia 18.04.2019 r.","norm_bases":["PB-LS-15 wydanie 02 z dnia 18.04.2019 r."],"lab_section":"Laboratorium Analizy Wody i Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (z obliczeń) PB-LS-15 wydanie 02 z dnia 18.04.2019 r. Woda, Scieki Stezenie azotu ogolnego (z obliczen) PB-LS-15 wydanie 02 z dnia 18.04.2019 r.","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Water and Wastewater Analysis Laboratory","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, Wastewater Total nitrogen concentration (calculated) Water and Wastewater Analysis Laboratory PB-LS-15 wydanie 02 z dnia 18.04.2019 r.","test_object_en":"Water, Wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、污水 总氮浓度（计算值） 水与废水分析实验室 PB-LS-15 wydanie 02 z dnia 18.04.2019 r.","test_object_zh":"水、污水","lab_section_zh":"水与废水分析实验室"}],"has_pdf":true}