🇵🇱 PIOTRKOWSKIE WODOCIĄGI I KANALIZACJA Sp. z o.o. PL
Water & wastewaterMicrobiology
PIOTRKOWSKIE WODOCIĄGI I KANALIZACJA Sp. z o.o. is a laboratory accredited by PCA under number AB 1098 (Piotrków Trybunalski, Poland). Its accreditation scope covers 31 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Water, Wastewater, Wastewater, Water. Most frequently used techniques: Spectrophotometric method, Ion chromatography with conductometric detection (IC-CD), Membrane filtration method.
At a glance
- Accreditation number: PCA AB 1098
- Methods in scope: 31
- Types of test objects: 4
- Techniques used: 12
- City: Piotrków Trybunalski, Poland
- Accreditation number
- AB 1098
- Accreditation body
- PCA
- Address
- ul. Przemysłowa 4, 97-300 Piotrków Trybunalski, LABORATORIUM, ul. Podole 7/9, 97-300 Piotrków Trybunalski
- City
- Piotrków Trybunalski, Poland
What this laboratory tests (4)
- Water intended for human consumption — 16 methods
- Water, Wastewater — 11 methods
- Wastewater — 3 methods
- Water — 1 method
Analytical techniques used (12)
- Spectrophotometric method — 9 methods
- Ion chromatography with conductometric detection (IC-CD) — 3 methods
- Membrane filtration method — 3 methods
- Electrochemical method — 2 methods
- Potentiometric method — 2 methods
- Titrimetric method — 2 methods
- Conductometric method — 1 method
- Gravimetric method — 1 method
- Manual and automatic method — 1 method
- Nephelometric method — 1 method
- Plate method (pour plate) — 1 method
- Visual method — 1 method
Laboratory locations
- Laboratorium —
Accreditation scope — test methods (31)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratory | |||||
| 1 | Wastewater | Sampling for chemical and physical testing | Manual and automatic method | PN-ISO 5667-10:2021-11 | |
| 2 | Wastewater | Total iron concentration Range (0,50 – 15) mg/dm3 |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 3 | Wastewater | Ammonium nitrogen concentration Range (2,0 – 200) mg/dm3 |
Titrimetric method | PN-EN 5664:2002 | |
| 4 | Water | Sampling for chemical and physical testing | PN-EN ISO 5667-6:2016-12 z wyłączeniem punktów 7.5, 7.6 | ||
| 5 | Water, Wastewater | Biochemical oxygen demand – BOD5 Range (0,5 – 6,0) mg/dm3 O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 6 | Water, Wastewater | Biochemical oxygen demand – BOD5 Range (3 – 4000) mg/dm3 O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 7 | Water, Wastewater | Chemical oxygen demand – COD Range (12,0 – 5000) mg/dm3 O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 8 | Water, Wastewater | Nitrite nitrogen concentration Range (0,030 – 5,0) mg/dm3 |
Spectrophotometric method | PN-EN 26777:1999 | |
| 9 | Water, Wastewater | Kjeldahl nitrogen concentration Range (2,0 – 150) mg/dm3 |
Titrimetric method | PN-EN 25663:2001 | |
| 10 | Water, Wastewater | Total phosphorus concentration Range (0,10 – 20) mg/dm3 |
Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 | |
| 11 | Water, Wastewater | Total suspended solids (TSS) Range (5,0 – 3000) mg/dm3 |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 12 | Water, Wastewater | Total nitrogen concentration (calculated) | PB-04 wydanie 1 z dnia 24.04.2023 | ||
| 13 | Water, Wastewater | pH Range 2,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 14 | Water, Wastewater | Nitrate nitrogen concentration Range (0,40 – 20) mg/dm3 |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 15 | Water, Wastewater | Anion concentrations chlorides (5,0 – 1000) mg/dm3 sulfates (5,0 – 1000) mg/dm3 |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 16 | Water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 17 | Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 18 | Water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12+ A1:2017-04 | |
| 19 | Water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12+ A1:2017-04 | |
| 20 | Water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 21 | Water intended for human consumption | Total viable count at 22°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 22 | Water intended for human consumption | Colour Range (5 – 20) mg/dm3 Pt |
Visual method | PN-EN ISO 7887:2012 + Ap1:2015-06 Metoda D | |
| 23 | Water intended for human consumption | Electrical conductivity Range (50 – 5000) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 24 | Water intended for human consumption | Turbidity Range (0,30 – 20) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 25 | Water intended for human consumption | Ammonium ion concentration Range (0,05 – 2,3) mg/dm3 |
Spectrophotometric method | PB-02 wydanie 1 z dnia 05.04.2023 | na podstawie testu Hach – LCK 304 | |
| 26 | Water intended for human consumption | Manganese concentration Range (15 – 700) μg/dm3 |
Spectrophotometric method | PB-03 wydanie 1 z dnia 05.04.2023 | na podstawie testu Hach 8149 | |
| 27 | Water intended for human consumption | Total iron concentration Range (50 – 5000) μg/dm3 |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 28 | Water intended for human consumption | Anion concentrations nitrates (1,8 – 90) mg/dm3 chlorides (5,0 – 1000) mg/dm3 sulfates (5,0 – 1000) mg/dm3 |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 29 | Water intended for human consumption | Nitrite concentration Range (0,100 – 16,5) mg/dm3 |
Spectrophotometric method | PN-EN 26777:1999 | |
| 30 | Water intended for human consumption | pH Range 4,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 31 | Water intended for human consumption | Colour Range (3,0 – 20) mg/dm3 Pt |
Spectrophotometric method | PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C | |
Reference standards (27)
PB-02 wydanie 1 z dnia 05.04.2023
PB-03 wydanie 1 z dnia 05.04.2023
PB-04 wydanie 1 z dnia 24.04.2023
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 5664:2002
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 5667-6:2016-12 z wyłączeniem punktów 7.5, 7.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 + Ap1:2015-06 Metoda D
PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12+ A1:2017-04
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6332:2001+Ap1:2016-06
na podstawie testu Hach 8149
na podstawie testu Hach – LCK 304