🇵🇱 PIOTRKOWSKIE WODOCIĄGI I KANALIZACJA Sp. z o.o. PL

PCA AB 1098 • Piotrków Trybunalski, Poland • 31 methods

Water & wastewaterMicrobiology

PIOTRKOWSKIE WODOCIĄGI I KANALIZACJA Sp. z o.o. is a laboratory accredited by PCA under number AB 1098 (Piotrków Trybunalski, Poland). Its accreditation scope covers 31 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Water, Wastewater, Wastewater, Water. Most frequently used techniques: Spectrophotometric method, Ion chromatography with conductometric detection (IC-CD), Membrane filtration method.

At a glance

  • Accreditation number: PCA AB 1098
  • Methods in scope: 31
  • Types of test objects: 4
  • Techniques used: 12
  • City: Piotrków Trybunalski, Poland
Accreditation number
AB 1098
Accreditation body
PCA
Address
ul. Przemysłowa 4, 97-300 Piotrków Trybunalski, LABORATORIUM, ul. Podole 7/9, 97-300 Piotrków Trybunalski
City
Piotrków Trybunalski, Poland

What this laboratory tests (4)

Analytical techniques used (12)

Laboratory locations

Accreditation scope — test methods (31)

No. Test object Methodology / Parameters Technique Reference document
Laboratory
1 Wastewater Sampling for chemical and physical testing Manual and automatic method PN-ISO 5667-10:2021-11
2 Wastewater Total iron concentration
Range (0,50 – 15) mg/dm3
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
3 Wastewater Ammonium nitrogen concentration
Range (2,0 – 200) mg/dm3
Titrimetric method PN-EN 5664:2002
4 Water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem punktów 7.5, 7.6
5 Water, Wastewater Biochemical oxygen demand – BOD5
Range (0,5 – 6,0) mg/dm3 O2
Electrochemical method PN-EN 1899-2:2002
6 Water, Wastewater Biochemical oxygen demand – BOD5
Range (3 – 4000) mg/dm3 O2
Electrochemical method PN-EN ISO 5815-1:2019-12
7 Water, Wastewater Chemical oxygen demand – COD
Range (12,0 – 5000) mg/dm3 O2
Spectrophotometric method PN-ISO 15705:2005
8 Water, Wastewater Nitrite nitrogen concentration
Range (0,030 – 5,0) mg/dm3
Spectrophotometric method PN-EN 26777:1999
9 Water, Wastewater Kjeldahl nitrogen concentration
Range (2,0 – 150) mg/dm3
Titrimetric method PN-EN 25663:2001
10 Water, Wastewater Total phosphorus concentration
Range (0,10 – 20) mg/dm3
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
11 Water, Wastewater Total suspended solids (TSS)
Range (5,0 – 3000) mg/dm3
Gravimetric method PN-EN 872:2007+Ap1:2007
12 Water, Wastewater Total nitrogen concentration (calculated) PB-04 wydanie 1 z dnia 24.04.2023
13 Water, Wastewater pH
Range 2,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
14 Water, Wastewater Nitrate nitrogen concentration
Range (0,40 – 20) mg/dm3
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
15 Water, Wastewater Anion concentrations
chlorides (5,0 – 1000) mg/dm3 sulfates (5,0 – 1000) mg/dm3
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
16 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
17 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
18 Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12+ A1:2017-04
19 Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12+ A1:2017-04
20 Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
21 Water intended for human consumption Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004
22 Water intended for human consumption Colour
Range (5 – 20) mg/dm3 Pt
Visual method PN-EN ISO 7887:2012 + Ap1:2015-06 Metoda D
23 Water intended for human consumption Electrical conductivity
Range (50 – 5000) μS/cm
Conductometric method PN-EN 27888:1999
24 Water intended for human consumption Turbidity
Range (0,30 – 20) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
25 Water intended for human consumption Ammonium ion concentration
Range (0,05 – 2,3) mg/dm3
Spectrophotometric method PB-02 wydanie 1 z dnia 05.04.2023 | na podstawie testu Hach – LCK 304
26 Water intended for human consumption Manganese concentration
Range (15 – 700) μg/dm3
Spectrophotometric method PB-03 wydanie 1 z dnia 05.04.2023 | na podstawie testu Hach 8149
27 Water intended for human consumption Total iron concentration
Range (50 – 5000) μg/dm3
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
28 Water intended for human consumption Anion concentrations
nitrates (1,8 – 90) mg/dm3 chlorides (5,0 – 1000) mg/dm3 sulfates (5,0 – 1000) mg/dm3
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
29 Water intended for human consumption Nitrite concentration
Range (0,100 – 16,5) mg/dm3
Spectrophotometric method PN-EN 26777:1999
30 Water intended for human consumption pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
31 Water intended for human consumption Colour
Range (3,0 – 20) mg/dm3 Pt
Spectrophotometric method PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C

Reference standards (27)

PB-02 wydanie 1 z dnia 05.04.2023
PB-03 wydanie 1 z dnia 05.04.2023
PB-04 wydanie 1 z dnia 24.04.2023
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 5664:2002
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 5667-6:2016-12 z wyłączeniem punktów 7.5, 7.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 + Ap1:2015-06 Metoda D
PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12+ A1:2017-04
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6332:2001+Ap1:2016-06
na podstawie testu Hach 8149
na podstawie testu Hach – LCK 304