{"lab":{"_id":"69ad52a3de79e566650fb596","accr_number":"AB 1098","country":"PL","accr_body":"PCA","address":"ul. Przemysłowa 4, 97-300 Piotrków Trybunalski, LABORATORIUM, ul. Podole 7/9, 97-300 Piotrków Trybunalski","categories":["water","microbiology"],"city":"Piotrków Trybunalski","imported_at":"2026-03-08T10:42:43.265Z","methods_count":31,"name":"PIOTRKOWSKIE WODOCIĄGI I KANALIZACJA Sp. z o.o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1098.pdf"],"scope_summary":"","search_text":"piotrkowskie wodociągi i kanalizacja sp. z o.o. ul. przemysłowa 4, 97-300 piotrków trybunalski, laboratorium, ul. podole 7/9, 97-300 piotrków trybunalski water other microbiology automotive pharma electronics","status":"active","updated_at":"2026-03-08T14:50:16.939Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:57:04.567Z","parse_date":"2026-08-13T07:57:04.567Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://pwik.piotrkow.pl/kontakt/","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling of drinking water"}],"issue":{"no":"19","date":"05.08.2026"},"map_coord":[51.393847,19.685183],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/db59b62860aee584fe4e6bce11857098/AB%201098.pdf","has_en":true,"category_counts":{"water":31,"microbiology":3},"category_scores":{"water":28.26,"microbiology":0.26},"has_zh":true,"lab_locations_zh":[{"name":"实验室","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d78d00636ba417e41a2d2","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method Laboratory PN-ISO 5667-10:2021-11","technique_en":"Manual and automatic method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工与自动法 实验室 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工与自动法"},{"_id":"6a7d78d00636ba417e41a2d3","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,50 – 15) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,50 – 15) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie żelaza ogólnego\nZakres (0,50 – 15) mg/dm3\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Scieki Stezenie zelaza ogolnego\nZakres (0,50 – 15) mg/dm3\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,50 – 15) mg/dm3"}],"search_en":"Wastewater Total iron concentration Spectrophotometric method Laboratory Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 15) mg/dm3"}],"search_zh":"污水 总铁浓度 分光光度法 实验室 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d78d00636ba417e41a2d4","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(2,0 – 200) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (2,0 – 200) mg/dm3\nMetoda miareczkowa","reference":"PN-EN 5664:2002","norm_bases":["PN-EN 5664:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (2,0 – 200) mg/dm3\nMetoda miareczkowa PN-EN 5664:2002 Scieki Stezenie azotu amonowego\nZakres (2,0 – 200) mg/dm3\nMetoda miareczkowa PN-EN 5664:2002","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,0 – 200) mg/dm3"}],"search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Laboratory Range PN-EN 5664:2002","technique_en":"Titrimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 200) mg/dm3"}],"search_zh":"污水 氨氮浓度 滴定法 实验室 范围 PN-EN 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a7d78d00636ba417e41a2d5","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem punktów 7.5, 7.6","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem punktów 7.5, 7.6"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wyłączeniem punktów 7.5, 7.6 Woda Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wylaczeniem punktow 7.5, 7.6","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing Laboratory PN-EN ISO 5667-6:2016-12 z wyłączeniem punktów 7.5, 7.6","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 实验室 PN-EN ISO 5667-6:2016-12 z wyłączeniem punktów 7.5, 7.6","test_object_zh":"水"},{"_id":"6a7d78d00636ba417e41a2d6","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/dm3 O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand – BOD5","parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/dm3 O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand – BOD5 Electrochemical method Laboratory Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/dm3 O2"}],"search_zh":"水、污水 五日生化需氧量（BOD5） 电化学法 实验室 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a7d78d00636ba417e41a2d7","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","parameters":[{"name":"Zakres","range":"(3 – 4000) mg/dm3 O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 4000) mg/dm3 O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 4000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 4000) mg/dm3 O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand – BOD5","parameters_en":[{"name":"Range","range":"(3 – 4000) mg/dm3 O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand – BOD5 Electrochemical method Laboratory Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(3 – 4000) mg/dm3 O2"}],"search_zh":"水、污水 五日生化需氧量（BOD5） 电化学法 实验室 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a7d78d00636ba417e41a2d8","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT","parameters":[{"name":"Zakres","range":"(12,0 – 5000) mg/dm3 O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT\nZakres (12,0 – 5000) mg/dm3 O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu – ChZT\nZakres (12,0 – 5000) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu – ChZT\nZakres (12,0 – 5000) mg/dm3 O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chemical oxygen demand – COD","parameters_en":[{"name":"Range","range":"(12,0 – 5000) mg/dm3 O2"}],"search_en":"Water, Wastewater Chemical oxygen demand – COD Spectrophotometric method Laboratory Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(12,0 – 5000) mg/dm3 O2"}],"search_zh":"水、污水 化学需氧量 － COD 分光光度法 实验室 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"化学需氧量 － COD"},{"_id":"6a7d78d00636ba417e41a2d9","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,030 – 5,0) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,030 – 5,0) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres (0,030 – 5,0) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Scieki Stezenie azotu azotynowego\nZakres (0,030 – 5,0) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,030 – 5,0) mg/dm3"}],"search_en":"Water, Wastewater Nitrite nitrogen concentration Spectrophotometric method Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,030 – 5,0) mg/dm3"}],"search_zh":"水、污水 亚硝态氮浓度 分光光度法 实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a7d78d00636ba417e41a2da","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(2,0 – 150) mg/dm3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (2,0 – 150) mg/dm3\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (2,0 – 150) mg/dm3\nMetoda miareczkowa PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (2,0 – 150) mg/dm3\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,0 – 150) mg/dm3"}],"search_en":"Water, Wastewater Kjeldahl nitrogen concentration Titrimetric method Laboratory Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 150) mg/dm3"}],"search_zh":"水、污水 凯氏氮浓度 滴定法 实验室 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a7d78d00636ba417e41a2db","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,10 – 20) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,10 – 20) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,10 – 20) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,10 – 20) mg/dm3\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,10 – 20) mg/dm3"}],"search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Laboratory Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 20) mg/dm3"}],"search_zh":"水、污水 总磷浓度 分光光度法 实验室 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a7d78d00636ba417e41a2dc","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5,0 – 3000) mg/dm3"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 3000) mg/dm3\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (5,0 – 3000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (5,0 – 3000) mg/dm3\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(5,0 – 3000) mg/dm3"}],"search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 3000) mg/dm3"}],"search_zh":"水、污水 总悬浮物 重量法 实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a7d78d00636ba417e41a2dd","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-04 wydanie 1 z dnia 24.04.2023","norm_bases":["PB-04 wydanie 1 z dnia 24.04.2023"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (z obliczeń) PB-04 wydanie 1 z dnia 24.04.2023 Woda, Scieki Stezenie azotu ogolnego (z obliczen) PB-04 wydanie 1 z dnia 24.04.2023","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, Wastewater Total nitrogen concentration (calculated) Laboratory PB-04 wydanie 1 z dnia 24.04.2023","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"总氮浓度（计算值）","search_zh":"水、污水 总氮浓度（计算值） 实验室 PB-04 wydanie 1 z dnia 24.04.2023","test_object_zh":"水、污水"},{"_id":"6a7d78d00636ba417e41a2de","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 2,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 10,0"}],"search_en":"Water, Wastewater pH Potentiometric method Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 10,0"}],"search_zh":"水、污水 pH 值 电位法 实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a7d78d00636ba417e41a2df","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,40 – 20) mg/dm3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,40 – 20) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu azotanowego\nZakres (0,40 – 20) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, Scieki Stezenie azotu azotanowego\nZakres (0,40 – 20) mg/dm3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,40 – 20) mg/dm3"}],"search_en":"Water, Wastewater Nitrate nitrogen concentration Ion chromatography with conductometric detection (IC-CD) Laboratory Range PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,40 – 20) mg/dm3"}],"search_zh":"水、污水 硝态氮浓度 离子色谱-电导检测法（IC-CD） 实验室 范围 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水"},{"_id":"6a7d78d00636ba417e41a2e0","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie anionów","parameters":[{"name":"chlorki","range":"(5,0 – 1000) mg/dm3"},{"name":"siarczany","range":"(5,0 – 1000) mg/dm3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nchlorki (5,0 – 1000) mg/dm3\nsiarczany (5,0 – 1000) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie anionów\nZakres:\nchlorki (5,0 – 1000) mg/dm3\nsiarczany (5,0 – 1000) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, Scieki Stezenie anionow\nZakres:\nchlorki (5,0 – 1000) mg/dm3\nsiarczany (5,0 – 1000) mg/dm3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Anion concentrations","parameters_en":[{"name":"chlorides","range":"(5,0 – 1000) mg/dm3"},{"name":"sulfates","range":"(5,0 – 1000) mg/dm3"}],"search_en":"Water, Wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) Laboratory chlorides sulfates PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, Wastewater","lab_section_zh":"实验室","methodology_zh":"阴离子浓度","search_zh":"水、污水 阴离子浓度 离子色谱-电导检测法（IC-CD） 实验室 氯化物 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水","parameters_zh":[{"name":"氯化物","range":"(5,0 – 1000) mg/dm3"},{"name":"硫酸盐","range":"(5,0 – 1000) mg/dm3"}]},{"_id":"6a7d78d00636ba417e41a2e1","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing Laboratory PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 实验室 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a7d78d00636ba417e41a2e2","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing Laboratory PN-EN ISO 19458:2007","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 实验室 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水"},{"_id":"6a7d78d00636ba417e41a2e3","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12+ A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12+ A1:2017-04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+ A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+ A1:2017-04","categories":["water","microbiology"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Coliform bacteria count","search_en":"Water intended for human consumption Coliform bacteria count Membrane filtration method Laboratory PN-EN ISO 9308-1:2014-12+ A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 实验室 PN-EN ISO 9308-1:2014-12+ A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a7d78d00636ba417e41a2e4","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12+ A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12+ A1:2017-04"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+ A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+ A1:2017-04","categories":["water","microbiology"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Escherichia coli count","search_en":"Water intended for human consumption Escherichia coli count Membrane filtration method Laboratory PN-EN ISO 9308-1:2014-12+ A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 实验室 PN-EN ISO 9308-1:2014-12+ A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a7d78d00636ba417e41a2e5","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Intestinal enterococci count","search_en":"Water intended for human consumption Intestinal enterococci count Membrane filtration method Laboratory PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"粪肠球菌计数","search_zh":"生活饮用水 粪肠球菌计数 膜过滤法 实验室 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a7d78d00636ba417e41a2e6","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total viable count at 22°C","search_en":"Water intended for human consumption Total viable count at 22°C Plate method (pour plate) Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"22°C 微生物总数","search_zh":"生活饮用水 22°C 微生物总数 平板法（倾注培养） 实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a7d78d00636ba417e41a2e7","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 20) mg/dm3 Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 – 20) mg/dm3 Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 + Ap1:2015-06 Metoda D","norm_bases":["PN-EN ISO 7887:2012 + Ap1:2015-06 Metoda D"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (5 – 20) mg/dm3 Pt\nMetoda wizualna PN-EN ISO 7887:2012 + Ap1:2015-06 Metoda D Woda do spozycia przez ludzi Barwa\nZakres (5 – 20) mg/dm3 Pt\nMetoda wizualna PN-EN ISO 7887:2012 + Ap1:2015-06 Metoda D","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 20) mg/dm3 Pt"}],"search_en":"Water intended for human consumption Colour Visual method Laboratory Range PN-EN ISO 7887:2012 + Ap1:2015-06 Metoda D","technique_en":"Visual method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 20) mg/dm3 Pt"}],"search_zh":"生活饮用水 色度 目视法 实验室 范围 PN-EN ISO 7887:2012 + Ap1:2015-06 Metoda D","technique_zh":"目视法","test_object_zh":"生活饮用水"},{"_id":"6a7d78d00636ba417e41a2e8","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(50 – 5000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (50 – 5000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (50 – 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (50 – 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(50 – 5000) μS/cm"}],"search_en":"Water intended for human consumption Electrical conductivity Conductometric method Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(50 – 5000) μS/cm"}],"search_zh":"生活饮用水 电导率 电导法 实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水"},{"_id":"6a7d78d00636ba417e41a2e9","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,30 – 20) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,30 – 20) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,30 – 20) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,30 – 20) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,30 – 20) NTU"}],"search_en":"Water intended for human consumption Turbidity Nephelometric method Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,30 – 20) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 实验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a7d78d00636ba417e41a2ea","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 2,3) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,05 – 2,3) mg/dm3\nMetoda spektrofotometryczna","reference":"PB-02 wydanie 1 z dnia 05.04.2023 | na podstawie testu Hach – LCK 304","norm_bases":["PB-02 wydanie 1 z dnia 05.04.2023","na podstawie testu Hach – LCK 304"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,05 – 2,3) mg/dm3\nMetoda spektrofotometryczna PB-02 wydanie 1 z dnia 05.04.2023 | na podstawie testu Hach – LCK 304 Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,05 – 2,3) mg/dm3\nMetoda spektrofotometryczna PB-02 wydanie 1 z dnia 05.04.2023 | na podstawie testu Hach – LCK 304","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,05 – 2,3) mg/dm3"}],"search_en":"Water intended for human consumption Ammonium ion concentration Spectrophotometric method Laboratory Range PB-02 wydanie 1 z dnia 05.04.2023 | na podstawie testu Hach – LCK 304","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 2,3) mg/dm3"}],"search_zh":"生活饮用水 铵离子浓度 分光光度法 实验室 范围 PB-02 wydanie 1 z dnia 05.04.2023 | na podstawie testu Hach – LCK 304","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7d78d00636ba417e41a2eb","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(15 – 700) μg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (15 – 700) μg/dm3\nMetoda spektrofotometryczna","reference":"PB-03 wydanie 1 z dnia 05.04.2023 | na podstawie testu Hach 8149","norm_bases":["PB-03 wydanie 1 z dnia 05.04.2023","na podstawie testu Hach 8149"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (15 – 700) μg/dm3\nMetoda spektrofotometryczna PB-03 wydanie 1 z dnia 05.04.2023 | na podstawie testu Hach 8149 Woda do spozycia przez ludzi Stezenie manganu\nZakres (15 – 700) μg/dm3\nMetoda spektrofotometryczna PB-03 wydanie 1 z dnia 05.04.2023 | na podstawie testu Hach 8149","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(15 – 700) μg/dm3"}],"search_en":"Water intended for human consumption Manganese concentration Spectrophotometric method Laboratory Range PB-03 wydanie 1 z dnia 05.04.2023 | na podstawie testu Hach 8149","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(15 – 700) μg/dm3"}],"search_zh":"生活饮用水 锰浓度 分光光度法 实验室 范围 PB-03 wydanie 1 z dnia 05.04.2023 | na podstawie testu Hach 8149","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7d78d00636ba417e41a2ec","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(50 – 5000) μg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (50 – 5000) μg/dm3\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (50 – 5000) μg/dm3\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (50 – 5000) μg/dm3\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(50 – 5000) μg/dm3"}],"search_en":"Water intended for human consumption Total iron concentration Spectrophotometric method Laboratory Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(50 – 5000) μg/dm3"}],"search_zh":"生活饮用水 总铁浓度 分光光度法 实验室 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7d78d00636ba417e41a2ed","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie anionów","parameters":[{"name":"azotany","range":"(1,8 – 90) mg/dm3"},{"name":"chlorki","range":"(5,0 – 1000) mg/dm3"},{"name":"siarczany","range":"(5,0 – 1000) mg/dm3"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nazotany (1,8 – 90) mg/dm3\nchlorki (5,0 – 1000) mg/dm3\nsiarczany (5,0 – 1000) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie anionów\nZakres:\nazotany (1,8 – 90) mg/dm3\nchlorki (5,0 – 1000) mg/dm3\nsiarczany (5,0 – 1000) mg/dm3\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda do spozycia przez ludzi Stezenie anionow\nZakres:\nazotany (1,8 – 90) mg/dm3\nchlorki (5,0 – 1000) mg/dm3\nsiarczany (5,0 – 1000) mg/dm3\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Anion concentrations","parameters_en":[{"name":"nitrates","range":"(1,8 – 90) mg/dm3"},{"name":"chlorides","range":"(5,0 – 1000) mg/dm3"},{"name":"sulfates","range":"(5,0 – 1000) mg/dm3"}],"search_en":"Water intended for human consumption Anion concentrations Ion chromatography with conductometric detection (IC-CD) Laboratory nitrates chlorides sulfates PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"阴离子浓度","search_zh":"生活饮用水 阴离子浓度 离子色谱-电导检测法（IC-CD） 实验室 硝酸盐 氯化物 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"生活饮用水","parameters_zh":[{"name":"硝酸盐","range":"(1,8 – 90) mg/dm3"},{"name":"氯化物","range":"(5,0 – 1000) mg/dm3"},{"name":"硫酸盐","range":"(5,0 – 1000) mg/dm3"}]},{"_id":"6a7d78d00636ba417e41a2ee","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,100 – 16,5) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,100 – 16,5) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,100 – 16,5) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,100 – 16,5) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,100 – 16,5) mg/dm3"}],"search_en":"Water intended for human consumption Nitrite concentration Spectrophotometric method Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,100 – 16,5) mg/dm3"}],"search_zh":"生活饮用水 亚硝酸盐浓度 分光光度法 实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7d78d00636ba417e41a2ef","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water intended for human consumption pH Potentiometric method Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"生活饮用水 pH 值 电位法 实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水"},{"_id":"6a7d78d00636ba417e41a2f0","lab_id":"69ad52a3de79e566650fb596","country":"PL","accr_number":"AB 1098","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(3,0 – 20) mg/dm3 Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (3,0 – 20) mg/dm3 Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (3,0 – 20) mg/dm3 Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C Woda do spozycia przez ludzi Barwa\nZakres (3,0 – 20) mg/dm3 Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(3,0 – 20) mg/dm3 Pt"}],"search_en":"Water intended for human consumption Colour Spectrophotometric method Laboratory Range PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(3,0 – 20) mg/dm3 Pt"}],"search_zh":"生活饮用水 色度 分光光度法 实验室 范围 PN-EN ISO 7887:2012+Ap1:2015-06 Metoda C","technique_zh":"分光光度法","test_object_zh":"生活饮用水"}],"has_pdf":true}