🇵🇱 MIEJSKIE WODOCIĄGI I KANALIZACJA Spółka z o.o. PL
Water & wastewaterMicrobiology
MIEJSKIE WODOCIĄGI I KANALIZACJA Spółka z o.o. is a laboratory accredited by PCA under number AB 1094 (Koszalin, Poland). Its accreditation scope covers 39 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Wastewater, Water, Water intended for human consumption, Water intended for human consumption, Sewage sludge. Most frequently used techniques: Spectrophotometric method, Gravimetric method, Titrimetric method.
At a glance
- Accreditation number: PCA AB 1094
- Methods in scope: 39
- Types of test objects: 5
- Techniques used: 14
- City: Koszalin, Poland
- Accreditation number
- AB 1094
- Accreditation body
- PCA
- Address
- ul. Wojska Polskiego 14, 75-711 Koszalin
- City
- Koszalin, Poland
What this laboratory tests (5)
- Wastewater — 15 methods
- Water, Water intended for human consumption — 13 methods
- Water intended for human consumption — 7 methods
- Sewage sludge — 2 methods
- Surface water — 2 methods
Analytical techniques used (14)
- Spectrophotometric method — 10 methods
- Gravimetric method — 4 methods
- Titrimetric method — 4 methods
- Membrane filtration method — 3 methods
- Electrochemical method — 2 methods
- Potentiometric method — 2 methods
- Simplified method, paired, non-forced choice — 2 methods
- Conductometric method — 1 method
- Manual method — 1 method
- Manual method; Automatic method — 1 method
- Nephelometric method — 1 method
- Plate method (pour plate) — 1 method
- Visual method — 1 method
- Volumetric method — 1 method
Laboratory locations
- LABORATORIUM BADANIA WODY — ul. Żwirowa 14; 75-711 Koszalin
- Pracownia Analiz Fizykochemicznych Wody — ul. Żwirowa 14; 75-711 Koszalin
- LABORATORIUM BADANIA ŚCIEKÓW — ul. Filtrowa; 75-900 Koszalin
- LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody —
Accreditation scope — test methods (39)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory | |||||
| 1 | Water, Water intended for human consumption | Nitrite concentration Range (0,020 – 0,50) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 2 | Water, Water intended for human consumption | Nitrate concentration Range (0,40 – 50,0) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 3 | Water, Water intended for human consumption | Ammonium ion concentration Range (0,15 – 2,0) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 4 | Water, Water intended for human consumption | pH Range 4,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 5 | Water, Water intended for human consumption | Manganese concentration Range (15 – 4000) μg/l |
Spectrophotometric method | PN-92/C-04590/03 | |
| 6 | Water, Water intended for human consumption | Electrical conductivity Range (100 – 2500) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 7 | Water, Water intended for human consumption | Turbidity Range (0,20 – 40) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 8 | Water, Water intended for human consumption | Colour Range (5 – 40) mg/l Pt |
Visual method | PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D | |
| 9 | Water, Water intended for human consumption | Total content of calcium and magnesium (total hardness) Range (20 – 500) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 10 | Water, Water intended for human consumption | Chloride concentration Range (5,0 – 250) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 11 | Water, Water intended for human consumption | Odour threshold number (TON) Range 1 – 2 |
Simplified method, paired, non-forced choice | PN-EN 1622:2006 | |
| 12 | Water, Water intended for human consumption | Iron concentration Range (60 – 10 000) μg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 13 | Water, Water intended for human consumption | Sulfate concentration Range (10 – 500) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 14 | Water intended for human consumption | Taste threshold number (TFN) Range 1-2 |
Simplified method, paired, non-forced choice | PN-EN 1622:2006 | |
| 15 | Water intended for human consumption | Sampling for chemical and physical testing (including sensory testing) | PN-ISO 5667-5:2017-10 | ||
| 16 | Water intended for human consumption | Total viable count at 22 oC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 17 | Water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017 | |
| 18 | Water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017 | |
| 19 | Water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 20 | Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 21 | Wastewater | Sampling for chemical and physical testing Temperature Range (5,0 – 40) °C |
Manual method; Automatic method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 22 | Wastewater | pH Range 4,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 23 | Wastewater | Settleable solids Range (0,5 – 100) ml/l |
Volumetric method | PN-72/C-04559/03 | |
| 24 | Wastewater | Total phosphorus concentration Range (0,3 – 120) mg/l |
Spectrophotometric method | PB-16:2014 wyd. 4 z dn. 17.01.2014 na podstawie testu kuwetowego Merck 1.14543.0001 i 1.14729.0001 | |
| 25 | Wastewater | Total nitrogen concentration Range (2,0 – 150 ) mg/l |
Spectrophotometric method | PB-24:2012 wyd. 1 z dn. 17.12.2012r. na podstawie testu kuwetowego Merck 1.14537.0001 i 1.14763.0001 | |
| 26 | Wastewater | Chemical oxygen demand - COD-Cr Range (4,0 – 10 000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 27 | Wastewater | Biochemical oxygen demand - BOD5 Range (1,0 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 28 | Wastewater | Total suspended solids (TSS) Range (2,0 – 2000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 29 | Wastewater | Nitrite nitrogen concentration Range (0,025 – 0,625) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 30 | Wastewater | Ammonium nitrogen concentration Range (1,0 – 350) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 31 | Wastewater | Chloride concentration range (5,0 – 1000) mg/l titrimetric method |
PN-ISO 9297:1994 | ||
| 32 | Wastewater | Biochemical oxygen demand - BOD5 Range (3 – 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 33 | Wastewater | Nitrate nitrogen concentration Range (0,50 – 15,0) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 34 | Wastewater | Kjeldahl nitrogen concentration, Range; (1,0 – 200) mg/l | Titrimetric method | PN-EN 25663:2001 | |
| 35 | Wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 36 | Surface water | Sampling for physical and chemical testing | Manual method | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 i 7.6 | PN-EN ISO 5667-6:2016-12/A11 | |
| 37 | Surface water | Total suspended solids (TSS) Range (2,0 – 2000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 38 | Sewage sludge | Dry residue Range (0,5 – 93,5) % |
PN-EN 15934:2013-02 | ||
| 39 | Sewage sludge | Loss on ignition Range (55,0 – 80,0) % Residue on ignition (calculated) |
Gravimetric method | PN-EN 15935:2022-01 z wyłaczeniem pkt. 7.4, 8.2 | |
Reference standards (34)
PB-16:2014 wyd. 4 z dn. 17.01.2014 na podstawie testu kuwetowego Merck 1.14543.0001 i 1.14729.0001
PB-24:2012 wyd. 1 z dn. 17.12.2012r. na podstawie testu kuwetowego Merck 1.14537.0001 i 1.14763.0001
PN-72/C-04559/03
PN-73/C-04576/14
PN-77/C-04584
PN-82/C-04576.08
PN-92/C-04590/03
PN-EN 15934:2013-02
PN-EN 15935:2022-01 z wyłaczeniem pkt. 7.4, 8.2
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 i 7.6
PN-EN ISO 5667-6:2016-12/A11
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994