{"lab":{"_id":"69ad52a3de79e566650fb58e","accr_number":"AB 1094","country":"PL","accr_body":"PCA","address":"ul. Wojska Polskiego 14, 75-711 Koszalin","categories":["water","microbiology"],"city":"Koszalin","imported_at":"2026-03-08T10:42:43.265Z","methods_count":39,"name":"MIEJSKIE WODOCIĄGI I KANALIZACJA Spółka z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1094.pdf"],"scope_summary":"","search_text":"miejskie wodociągi i kanalizacja spółka z o.o. ul. wojska polskiego 14, 75-711 koszalin other water pharma electronics microbiology automotive","status":"active","updated_at":"2026-03-08T14:50:16.400Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:56:59.471Z","parse_date":"2026-08-13T07:56:59.471Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://mwik.koszalin.pl/laboratoria","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi i ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"},{"codes":"N/32","pl":"Badania właściwości fizycznych osadów ściekowych","en":"Tests of physical properties of sediments"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling of drinking water"},{"codes":"Q/28","pl":"Badania sensoryczne wody","en":"Sensory tests of water"},{"codes":"Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody do spożycia przez ludzi","en":"Sensory tests and sampling of drinking water"}],"issue":{"no":"19","date":"29.06.2026"},"map_coord":[54.189113,16.196234],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM BADANIA WODY","address":"ul. Żwirowa 14; 75-711 Koszalin","city":"Koszalin","postal":"75-711"},{"name":"Pracownia Analiz Fizykochemicznych Wody","address":"ul. Żwirowa 14; 75-711 Koszalin","city":"Koszalin","postal":"75-711"},{"name":"LABORATORIUM BADANIA ŚCIEKÓW","address":"ul. Filtrowa; 75-900 Koszalin","city":"Koszalin","postal":"75-900"},{"name":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/a772f0ae7dee09123bbbeddccf9dd439/AB%201094.pdf","has_en":true,"category_counts":{"water":39,"microbiology":3},"category_scores":{"water":36.21,"microbiology":0.21},"has_zh":true,"lab_locations_zh":[{"name":"LABORATORIUM BADANIA WODY","address":"ul. Żwirowa 14; 75-711 Koszalin","city":"Koszalin","postal":"75-711"},{"name":"Pracownia Analiz Fizykochemicznych Wody","address":"ul. Żwirowa 14; 75-711 Koszalin","city":"Koszalin","postal":"75-711"},{"name":"LABORATORIUM BADANIA ŚCIEKÓW","address":"ul. Filtrowa; 75-900 Koszalin","city":"Koszalin","postal":"75-900"},{"name":"水检测实验室；水理化分析实验室","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d78cb0636ba417e41a245","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,020 – 0,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,020 – 0,50) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,020 – 0,50) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,020 – 0,50) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,020 – 0,50) mg/l"}],"search_en":"Water, Water intended for human consumption Nitrite concentration Spectrophotometric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 0,50) mg/l"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 水检测实验室；水理化分析实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a246","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,40 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,40 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,40 – 50,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, Woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,40 – 50,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,40 – 50,0) mg/l"}],"search_en":"Water, Water intended for human consumption Nitrate concentration Spectrophotometric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,40 – 50,0) mg/l"}],"search_zh":"水、生活饮用水 硝酸盐浓度 分光光度法 水检测实验室；水理化分析实验室 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a247","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,15 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,15 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,15 – 2,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,15 – 2,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,15 – 2,0) mg/l"}],"search_en":"Water, Water intended for human consumption Ammonium ion concentration Spectrophotometric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,15 – 2,0) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 水检测实验室；水理化分析实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a248","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water, Water intended for human consumption pH Potentiometric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 水检测实验室；水理化分析实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a249","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(15 – 4000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (15 – 4000) μg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/03","norm_bases":["PN-92/C-04590/03"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (15 – 4000) μg/l\nMetoda spektrofotometryczna PN-92/C-04590/03 Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (15 – 4000) μg/l\nMetoda spektrofotometryczna PN-92/C-04590/03","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(15 – 4000) μg/l"}],"search_en":"Water, Water intended for human consumption Manganese concentration Spectrophotometric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-92/C-04590/03","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(15 – 4000) μg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 水检测实验室；水理化分析实验室 范围 PN-92/C-04590/03","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a24a","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 – 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (100 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (100 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 – 2500) μS/cm"}],"search_en":"Water, Water intended for human consumption Electrical conductivity Conductometric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 2500) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 水检测实验室；水理化分析实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a24b","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 40) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 40) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,20 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 40) NTU"}],"search_en":"Water, Water intended for human consumption Turbidity Nephelometric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 40) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 水检测实验室；水理化分析实验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a24c","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 40) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 – 40) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (5 – 40) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D Woda, Woda do spozycia przez ludzi Barwa\nZakres (5 – 40) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 40) mg/l Pt"}],"search_en":"Water, Water intended for human consumption Colour Visual method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","technique_en":"Visual method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 40) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 目视法 水检测实验室；水理化分析实验室 范围 PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","technique_zh":"目视法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a24d","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(20 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (20 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (20 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (20 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(20 – 500) mg/l CaCO3"}],"search_en":"Water, Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(20 – 500) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 水检测实验室；水理化分析实验室 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a24e","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 250) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,0 – 250) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,0 – 250) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 250) mg/l"}],"search_en":"Water, Water intended for human consumption Chloride concentration Titrimetric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 250) mg/l"}],"search_zh":"水、生活饮用水 氯化物浓度 滴定法 水检测实验室；水理化分析实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a24f","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba progowa zapachu (TON)","parameters":[{"name":"Zakres","range":"1 – 2"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa zapachu (TON)\nZakres 1 – 2\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba progowa zapachu (TON)\nZakres 1 – 2\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda, Woda do spozycia przez ludzi Liczba progowa zapachu (TON)\nZakres 1 – 2\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Odour threshold number (TON)","parameters_en":[{"name":"Range","range":"1 – 2"}],"search_en":"Water, Water intended for human consumption Odour threshold number (TON) Simplified method, paired, non-forced choice WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"1 – 2"}],"search_zh":"水、生活饮用水 嗅阈值（TON） 简化法，成对，非强制选择 水检测实验室；水理化分析实验室 范围 PN-EN 1622:2006","test_object_zh":"水、生活饮用水","technique_zh":"简化法，成对，非强制选择","lab_section_zh":"水检测实验室；水理化分析实验室","methodology_zh":"嗅阈值（TON）"},{"_id":"6a7d78cb0636ba417e41a250","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(60 – 10 000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (60 – 10 000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza\nZakres (60 – 10 000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, Woda do spozycia przez ludzi Stezenie zelaza\nZakres (60 – 10 000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(60 – 10 000) μg/l"}],"search_en":"Water, Water intended for human consumption Iron concentration Spectrophotometric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(60 – 10 000) μg/l"}],"search_zh":"水、生活饮用水 铁浓度 分光光度法 水检测实验室；水理化分析实验室 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a251","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 500) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie siarczanów\nZakres (10 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, Woda do spozycia przez ludzi Stezenie siarczanow\nZakres (10 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 500) mg/l"}],"search_en":"Water, Water intended for human consumption Sulfate concentration Gravimetric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 500) mg/l"}],"search_zh":"水、生活饮用水 硫酸盐浓度 重量法 水检测实验室；水理化分析实验室 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、生活饮用水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a252","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba progowa smaku (TFN)","parameters":[{"name":"Zakres","range":"1-2"}],"technique":"Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda uproszczona, parzysta, wybór niewymuszony"],"computed":[],"activity":"Liczba progowa smaku (TFN)\nZakres 1-2\nMetoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku (TFN)\nZakres 1-2\nMetoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa smaku (TFN)\nZakres 1-2\nMetoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Taste threshold number (TFN)","parameters_en":[{"name":"Range","range":"1-2"}],"search_en":"Water intended for human consumption Taste threshold number (TFN) Simplified method, paired, non-forced choice WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-EN 1622:2006","technique_en":"Simplified method, paired, non-forced choice","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"1-2"}],"search_zh":"生活饮用水 味阈值（TFN） 简化法，成对，非强制选择 水检测实验室；水理化分析实验室 范围 PN-EN 1622:2006","test_object_zh":"生活饮用水","technique_zh":"简化法，成对，非强制选择","lab_section_zh":"水检测实验室；水理化分析实验室","methodology_zh":"味阈值（TFN）"},{"_id":"6a7d78cb0636ba417e41a253","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Sampling for chemical and physical testing (including sensory testing)","search_en":"Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 化学和物理检测采样（含感官检测） 水检测实验室；水理化分析实验室 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水","lab_section_zh":"水检测实验室；水理化分析实验室","methodology_zh":"化学和物理检测采样（含感官检测）"},{"_id":"6a7d78cb0636ba417e41a254","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22 oC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22 oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Total viable count at 22 oC","search_en":"Water intended for human consumption Total viable count at 22 oC Plate method (pour plate) WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","methodology_zh":"22 °C 微生物总数","search_zh":"生活饮用水 22 °C 微生物总数 平板法（倾注培养） 水检测实验室；水理化分析实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a255","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017","categories":["water","microbiology"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Coliform bacteria count","search_en":"Water intended for human consumption Coliform bacteria count Membrane filtration method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory PN-EN ISO 9308-1:2014-12 +A1:2017","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 水检测实验室；水理化分析实验室 PN-EN ISO 9308-1:2014-12 +A1:2017","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a256","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017 Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017","categories":["water","microbiology"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Escherichia coli count","search_en":"Water intended for human consumption Escherichia coli count Membrane filtration method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory PN-EN ISO 9308-1:2014-12 +A1:2017","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 水检测实验室；水理化分析实验室 PN-EN ISO 9308-1:2014-12 +A1:2017","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a257","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Intestinal enterococci count","search_en":"Water intended for human consumption Intestinal enterococci count Membrane filtration method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"生活饮用水 粪肠球菌计数 膜过滤法 水检测实验室；水理化分析实验室 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a258","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory PN-EN ISO 19458:2007","test_object_en":"Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 水检测实验室；水理化分析实验室 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a259","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(5,0 – 40) °C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (5,0 – 40) °C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (5,0 – 40) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (5,0 – 40) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(5,0 – 40) °C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Temperature Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(5,0 – 40) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 水检测实验室；水理化分析实验室 温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a25a","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Wastewater pH Potentiometric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"污水 pH 值 电位法 水检测实验室；水理化分析实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a25b","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny łatwoopadające","parameters":[{"name":"Zakres","range":"(0,5 – 100) ml/l"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Zawiesiny łatwoopadające\nZakres (0,5 – 100) ml/l\nMetoda objętościowa","reference":"PN-72/C-04559/03","norm_bases":["PN-72/C-04559/03"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny łatwoopadające\nZakres (0,5 – 100) ml/l\nMetoda objętościowa PN-72/C-04559/03 Scieki Zawiesiny latwoopadajace\nZakres (0,5 – 100) ml/l\nMetoda objetosciowa PN-72/C-04559/03","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Settleable solids","parameters_en":[{"name":"Range","range":"(0,5 – 100) ml/l"}],"search_en":"Wastewater Settleable solids Volumetric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-72/C-04559/03","technique_en":"Volumetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 100) ml/l"}],"search_zh":"污水 易沉降悬浮物 容量法 水检测实验室；水理化分析实验室 范围 PN-72/C-04559/03","test_object_zh":"污水","lab_section_zh":"水检测实验室；水理化分析实验室","technique_zh":"容量法","methodology_zh":"易沉降悬浮物"},{"_id":"6a7d78cb0636ba417e41a25c","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,3 – 120) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,3 – 120) mg/l\nMetoda spektrofotometryczna","reference":"PB-16:2014 wyd. 4 z dn. 17.01.2014 na podstawie testu kuwetowego Merck 1.14543.0001 i 1.14729.0001","norm_bases":["PB-16:2014 wyd. 4 z dn. 17.01.2014 na podstawie testu kuwetowego Merck 1.14543.0001 i 1.14729.0001"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,3 – 120) mg/l\nMetoda spektrofotometryczna PB-16:2014 wyd. 4 z dn. 17.01.2014 na podstawie testu kuwetowego Merck 1.14543.0001 i 1.14729.0001 Scieki Stezenie fosforu ogolnego\nZakres (0,3 – 120) mg/l\nMetoda spektrofotometryczna PB-16:2014 wyd. 4 z dn. 17.01.2014 na podstawie testu kuwetowego Merck 1.14543.0001 i 1.14729.0001","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,3 – 120) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PB-16:2014 wyd. 4 z dn. 17.01.2014 na podstawie testu kuwetowego Merck 1.14543.0001 i 1.14729.0001","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,3 – 120) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 水检测实验室；水理化分析实验室 范围 PB-16:2014 wyd. 4 z dn. 17.01.2014 na podstawie testu kuwetowego Merck 1.14543.0001 i 1.14729.0001","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a25d","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(2,0 – 150 ) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (2,0 – 150 ) mg/l\nMetoda spektrofotometryczna","reference":"PB-24:2012 wyd. 1 z dn. 17.12.2012r. na podstawie testu kuwetowego Merck 1.14537.0001 i 1.14763.0001","norm_bases":["PB-24:2012 wyd. 1 z dn. 17.12.2012r. na podstawie testu kuwetowego Merck 1.14537.0001 i 1.14763.0001"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (2,0 – 150 ) mg/l\nMetoda spektrofotometryczna PB-24:2012 wyd. 1 z dn. 17.12.2012r. na podstawie testu kuwetowego Merck 1.14537.0001 i 1.14763.0001 Scieki Stezenie azotu ogolnego\nZakres (2,0 – 150 ) mg/l\nMetoda spektrofotometryczna PB-24:2012 wyd. 1 z dn. 17.12.2012r. na podstawie testu kuwetowego Merck 1.14537.0001 i 1.14763.0001","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,0 – 150 ) mg/l"}],"search_en":"Wastewater Total nitrogen concentration Spectrophotometric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PB-24:2012 wyd. 1 z dn. 17.12.2012r. na podstawie testu kuwetowego Merck 1.14537.0001 i 1.14763.0001","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 150 ) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 水检测实验室；水理化分析实验室 范围 PB-24:2012 wyd. 1 z dn. 17.12.2012r. na podstawie testu kuwetowego Merck 1.14537.0001 i 1.14763.0001","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a25e","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(4,0 – 10 000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (4,0 – 10 000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (4,0 – 10 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (4,0 – 10 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(4,0 – 10 000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(4,0 – 10 000) mg/l O2"}],"search_zh":"污水 化学需氧量（COD-Cr） 分光光度法 水检测实验室；水理化分析实验室 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"水检测实验室；水理化分析实验室","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a7d78cb0636ba417e41a25f","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(1,0 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(1,0 – 6,0) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand - BOD5 Electrochemical method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 6,0) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 电化学法 水检测实验室；水理化分析实验室 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a260","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/l"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 水检测实验室；水理化分析实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a261","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,025 – 0,625) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,025 – 0,625) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres (0,025 – 0,625) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego\nZakres (0,025 – 0,625) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,025 – 0,625) mg/l"}],"search_en":"Wastewater Nitrite nitrogen concentration Spectrophotometric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,025 – 0,625) mg/l"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 水检测实验室；水理化分析实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a262","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(1,0 – 350) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (1,0 – 350) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (1,0 – 350) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres (1,0 – 350) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 350) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 350) mg/l"}],"search_zh":"污水 氨氮浓度 滴定法 水检测实验室；水理化分析实验室 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a263","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"zakres","range":"(5,0 – 1000) mg/l"},{"name":"metoda miareczkowa"}],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chlorków\nZakres:\nzakres (5,0 – 1000) mg/l\nmetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chlorków\nZakres:\nzakres (5,0 – 1000) mg/l\nmetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres:\nzakres (5,0 – 1000) mg/l\nmetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"range","range":"(5,0 – 1000) mg/l"},{"name":"titrimetric method"}],"search_en":"Wastewater Chloride concentration WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory range titrimetric method PN-ISO 9297:1994","test_object_en":"Wastewater","methodology_zh":"氯化物浓度","search_zh":"污水 氯化物浓度 水检测实验室；水理化分析实验室 范围 PN-ISO 9297:1994","test_object_zh":"污水","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/l"},{"name":"metoda miareczkowa"}],"lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a264","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3 – 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand - BOD5 Electrochemical method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 电化学法 水检测实验室；水理化分析实验室 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a265","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,50 – 15,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,50 – 15,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,50 – 15,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Scieki Stezenie azotu azotanowego\nZakres (0,50 – 15,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 15,0) mg/l"}],"search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 15,0) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 水检测实验室；水理化分析实验室 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a266","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu Kjeldahla, Zakres; (1,0 – 200) mg/l","parameters":[],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla, Zakres; (1,0 – 200) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu Kjeldahla, Zakres; (1,0 – 200) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla, Zakres; (1,0 – 200) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Kjeldahl nitrogen concentration, Range; (1,0 – 200) mg/l","search_en":"Wastewater Kjeldahl nitrogen concentration, Range; (1,0 – 200) mg/l Titrimetric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Wastewater","search_zh":"污水 滴定法 水检测实验室；水理化分析实验室 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a267","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Wastewater Total nitrogen concentration (calculated) WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory PN-73/C-04576/14","test_object_en":"Wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） 水检测实验室；水理化分析实验室 PN-73/C-04576/14","test_object_zh":"污水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a268","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda powierzchniowa","methodology":"Pobieranie próbek do badań fizycznych i chemicznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań fizycznych i chemicznych\nMetoda manualna","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 i 7.6 | PN-EN ISO 5667-6:2016-12/A11","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 i 7.6","PN-EN ISO 5667-6:2016-12/A11"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda powierzchniowa Pobieranie próbek do badań fizycznych i chemicznych\nMetoda manualna PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 i 7.6 | PN-EN ISO 5667-6:2016-12/A11 Woda powierzchniowa Pobieranie probek do badan fizycznych i chemicznych\nMetoda manualna PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.5 i 7.6 | PN-EN ISO 5667-6:2016-12/A11","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Sampling for physical and chemical testing","search_en":"Surface water Sampling for physical and chemical testing Manual method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 i 7.6 | PN-EN ISO 5667-6:2016-12/A11","technique_en":"Manual method","test_object_en":"Surface water","methodology_zh":"物理与化学检测用样品采集","search_zh":"地表水 物理与化学检测用样品采集 手工法 水检测实验室；水理化分析实验室 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5 i 7.6 | PN-EN ISO 5667-6:2016-12/A11","technique_zh":"手工法","test_object_zh":"地表水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a269","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Woda powierzchniowa","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda powierzchniowa Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda powierzchniowa Zawiesiny ogolne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/l"}],"search_en":"Surface water Total suspended solids (TSS) Gravimetric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Surface water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/l"}],"search_zh":"地表水 总悬浮物 重量法 水检测实验室；水理化分析实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"地表水","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a26a","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(0,5 – 93,5) %"}],"technique":null,"techniques":[],"computed":[],"activity":"Sucha pozostałość\nZakres (0,5 – 93,5) %","reference":"PN-EN 15934:2013-02","norm_bases":["PN-EN 15934:2013-02"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość\nZakres (0,5 – 93,5) % PN-EN 15934:2013-02 Osady sciekowe Sucha pozostalosc\nZakres (0,5 – 93,5) % PN-EN 15934:2013-02","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(0,5 – 93,5) %"}],"search_en":"Sewage sludge Dry residue WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range PN-EN 15934:2013-02","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,5 – 93,5) %"}],"search_zh":"污泥 干残渣 水检测实验室；水理化分析实验室 范围 PN-EN 15934:2013-02","test_object_zh":"污泥","methodology_zh":"干残渣","lab_section_zh":"水检测实验室；水理化分析实验室"},{"_id":"6a7d78cb0636ba417e41a26b","lab_id":"69ad52a3de79e566650fb58e","country":"PL","accr_number":"AB 1094","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Straty podczas prażenia","parameters":[{"name":"Zakres","range":"(55,0 – 80,0) %"},{"name":"Pozostałość po prażeniu (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty podczas prażenia\nZakres:\nZakres (55,0 – 80,0) %\nPozostałość po prażeniu (z obliczeń)\nMetoda wagowa","reference":"PN-EN 15935:2022-01 z wyłaczeniem pkt. 7.4, 8.2","norm_bases":["PN-EN 15935:2022-01 z wyłaczeniem pkt. 7.4, 8.2"],"lab_section":"LABORATORIUM BADANIA WODY; Pracownia Analiz Fizykochemicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Straty podczas prażenia\nZakres:\nZakres (55,0 – 80,0) %\nPozostałość po prażeniu (z obliczeń)\nMetoda wagowa PN-EN 15935:2022-01 z wyłaczeniem pkt. 7.4, 8.2 Osady sciekowe Straty podczas prazenia\nZakres:\nZakres (55,0 – 80,0) %\nPozostalosc po prazeniu (z obliczen)\nMetoda wagowa PN-EN 15935:2022-01 z wylaczeniem pkt. 7.4, 8.2","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory","methodology_en":"Loss on ignition","parameters_en":[{"name":"Range","range":"(55,0 – 80,0) %"},{"name":"Residue on ignition (calculated)"}],"search_en":"Sewage sludge Loss on ignition Gravimetric method WATER TESTING LABORATORY; Water Physicochemical Analyses Laboratory Range Residue on ignition (calculated) PN-EN 15935:2022-01 z wyłaczeniem pkt. 7.4, 8.2","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(55,0 – 80,0) %"},{"name":"Pozostałość po prażeniu (z obliczeń)"}],"search_zh":"污泥 重量法 水检测实验室；水理化分析实验室 范围 PN-EN 15935:2022-01 z wyłaczeniem pkt. 7.4, 8.2","technique_zh":"重量法","test_object_zh":"污泥","lab_section_zh":"水检测实验室；水理化分析实验室"}],"has_pdf":true}