🇵🇱 WOJSKOWA AKADEMIA TECHNICZNA PL

PCA AB 109 • Warszawa, Poland • 14 methods

Metrology & calibrationMaterials & polymers

WOJSKOWA AKADEMIA TECHNICZNA is a laboratory accredited by PCA under number AB 109 (Warszawa, Poland). Its accreditation scope covers 14 test methods in the following areas: Metrology & calibration, Materials & polymers. Test objects include: E Opaque solid materials, Thermal cameras, E Optoelectronic devices emitting laser radiation, E Optical material.

At a glance

  • Accreditation number: PCA AB 109
  • Methods in scope: 14
  • Types of test objects: 6
  • City: Warszawa, Poland
Accreditation number
AB 109
Accreditation body
PCA
Address
im. Jarosława Dąbrowskiego, INSTYTUT OPTOELEKTRONIKI, LABORATORIUM BADAWCZE
City
Warszawa, Poland

What this laboratory tests (6)

Accreditation scope — test methods (14)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 E Optoelectronic devices emitting laser radiation Laser radiation pulse energy (direct measurement method) Normy Procedura PB 01 Standards Procedure PB 01
2 E Optoelectronic devices emitting laser radiation Power of continuum laser radiation (direct measurement method) Normy Procedura PB 02 Standards Procedure PB 02
3 E Optoelectronic devices emitting laser radiation Safety class of devices emitting laser radiation (direct measurement method) Normy Procedura PB 07 Standards Procedure PB 07
4 E Optical material Total spectral transmittance (direct measurement method) Normy Procedura PB 06 Standards Procedure PB 06
5 E Power/energy meters of laser radiation Correction factor (comparative method and a direct measurement) Normy Procedura PB 05 Standards Procedure PB 05
6 E TV and LLLTV cameras, night vision devices, other Function of the minimum resolved contrast and spatial resolution (direct measurement method) Normy Procedura PB 10 Standards Procedure PB 10
7 Thermal cameras Power equivalent to NETD (direct measurement method) Normy Procedura PB 09 Standards Procedure PB 09
8 Thermal cameras Function of the minimum resolved temperature difference MRTD (direct measurement method) Normy Procedura PB 09 Standards Procedure PB 09
9 Thermal cameras Detection, recognition and identification ranges of a device (from calculations) Normy Procedura PB 09 Standards Procedure PB 09
10 Thermal cameras Field of view FOV (direct measurement method) Normy Procedura PB 09 Standards Procedure PB 09
11 E Opaque solid materials Reflectance (direct measurement method) Normy Procedura PB 08 Standards Procedure PB 08
12 E Opaque solid materials Solar reflectance (from calculations)
13 E Opaque solid materials Relative emissivity (from calculations)
14 E Opaque solid materials Solar reflectance index SRI (from calculations)

Reference standards (8)

Normy Procedura PB 01 Standards Procedure PB 01
Normy Procedura PB 02 Standards Procedure PB 02
Normy Procedura PB 05 Standards Procedure PB 05
Normy Procedura PB 06 Standards Procedure PB 06
Normy Procedura PB 07 Standards Procedure PB 07
Normy Procedura PB 08 Standards Procedure PB 08
Normy Procedura PB 09 Standards Procedure PB 09
Normy Procedura PB 10 Standards Procedure PB 10