{"lab":{"_id":"69ad52a3de79e566650fb11f","accr_number":"AB 109","country":"PL","accr_body":"PCA","address":"im. Jarosława Dąbrowskiego, INSTYTUT OPTOELEKTRONIKI, LABORATORIUM BADAWCZE","categories":["materials"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":14,"name":"WOJSKOWA AKADEMIA TECHNICZNA","parse_status":"parsed","parse_version":2,"pdf_files":["AB_109.pdf"],"scope_summary":"","search_text":"wojskowa akademia techniczna im. jarosława dąbrowskiego, instytut optoelektroniki, laboratorium badawcze other electronics metrology pharma materials environment","status":"active","updated_at":"2026-03-08T14:50:16.200Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:16.200Z","parse_date":"2026-07-17T16:18:51.798Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://ioe.wat.edu.pl/laboratorium-badawcze-akredytowane/","fields_of_testing":[{"codes":"E/6; N/5, N/6; N/12; N/16, N/17","pl":"Badania elektryczne i elektroniczne urządzeń optoelektronicznych","en":"Electric and electronic testing of optoelectronic devices"}],"issue":{"no":"22","date":"15.09.2025"},"map_coord":[52.231958,21.006725],"map_geo":"nominatim-city","has_zh":true,"has_en":true,"category_counts":{"other":9,"materials":5},"category_scores":{"other":5.79,"materials":1.79}},"methods":[{"_id":"6a5a55eb9af9f73f3824fecd","lab_id":"69ad52a3de79e566650fb11f","country":"PL","accr_number":"AB 109","accr_body":"PCA","test_object":"E Urządzenia optoelektroniczne emitujące promieniowanie Optoelectronic devices emitting laser radiation","test_object_en":"E Optoelectronic devices emitting laser radiation","methodology":"Energia impulsu promieniowania laserowego (metoda pomiarowa bezpośrednia) Laser pulse energy (direct measurement method)","methodology_en":"Laser radiation pulse energy (direct measurement method)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Energia impulsu promieniowania laserowego (metoda pomiarowa bezpośrednia) Laser pulse energy (direct measurement method)","reference":"Normy Procedura PB 01 Standards Procedure PB 01","norm_bases":["Normy Procedura PB 01 Standards Procedure PB 01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Urządzenia optoelektroniczne emitujące promieniowanie Optoelectronic devices emitting laser radiation Energia impulsu promieniowania laserowego (metoda pomiarowa bezpośrednia) Laser pulse energy (direct measurement method) Normy Procedura PB 01 Standards Procedure PB 01 E Urzadzenia optoelektroniczne emitujace promieniowanie Optoelectronic devices emitting laser radiation Energia impulsu promieniowania laserowego (metoda pomiarowa bezposrednia) Laser pulse energy (direct measurement method) Normy Procedura PB 01 Standards Procedure PB 01","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"激光脉冲能量（直接测量法）Laser pulse energy (direct measurement method)","search_zh":"E 发射辐射的光电装置 Optoelectronic devices emitting laser radiation 激光脉冲能量（直接测量法）Laser pulse energy (direct measurement method) Normy Procedura PB 01 Standards Procedure PB 01","test_object_zh":"E 发射辐射的光电装置 Optoelectronic devices emitting laser radiation","search_en":"E Optoelectronic devices emitting laser radiation Laser radiation pulse energy (direct measurement method) Normy Procedura PB 01 Standards Procedure PB 01"},{"_id":"6a5a55eb9af9f73f3824fece","lab_id":"69ad52a3de79e566650fb11f","country":"PL","accr_number":"AB 109","accr_body":"PCA","test_object":"E Urządzenia optoelektroniczne emitujące promieniowanie Optoelectronic devices emitting laser radiation","test_object_en":"E Optoelectronic devices emitting laser radiation","methodology":"Moc ciągłego promieniowania laserowego (metoda pomiarowa bezpośrednia) Power of continuum laser radiation (direct measurement method)","methodology_en":"Power of continuum laser radiation (direct measurement method)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moc ciągłego promieniowania laserowego (metoda pomiarowa bezpośrednia) Power of continuum laser radiation (direct measurement method)","reference":"Normy Procedura PB 02 Standards Procedure PB 02","norm_bases":["Normy Procedura PB 02 Standards Procedure PB 02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Urządzenia optoelektroniczne emitujące promieniowanie Optoelectronic devices emitting laser radiation Moc ciągłego promieniowania laserowego (metoda pomiarowa bezpośrednia) Power of continuum laser radiation (direct measurement method) Normy Procedura PB 02 Standards Procedure PB 02 E Urzadzenia optoelektroniczne emitujace promieniowanie Optoelectronic devices emitting laser radiation Moc ciaglego promieniowania laserowego (metoda pomiarowa bezposrednia) Power of continuum laser radiation (direct measurement method) Normy Procedura PB 02 Standards Procedure PB 02","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"连续激光辐射功率（直接测量法）Power of continuum laser radiation (direct measurement method)","search_zh":"E 发射辐射的光电装置 Optoelectronic devices emitting laser radiation 连续激光辐射功率（直接测量法）Power of continuum laser radiation (direct measurement method) Normy Procedura PB 02 Standards Procedure PB 02","test_object_zh":"E 发射辐射的光电装置 Optoelectronic devices emitting laser radiation","search_en":"E Optoelectronic devices emitting laser radiation Power of continuum laser radiation (direct measurement method) Normy Procedura PB 02 Standards Procedure PB 02"},{"_id":"6a5a55eb9af9f73f3824fecf","lab_id":"69ad52a3de79e566650fb11f","country":"PL","accr_number":"AB 109","accr_body":"PCA","test_object":"E Urządzenia optoelektroniczne emitujące promieniowanie laserowe Optoelectronic devices emitting laser radiation","test_object_en":"E Optoelectronic devices emitting laser radiation","methodology":"Klasa bezpieczeństwa urządzeń emitujących promieniowanie laserowe (metoda pomiarowa bezpośrednia) Safety class of devices emitting laser radiation (direct measurement method)","methodology_en":"Safety class of devices emitting laser radiation (direct measurement method)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Klasa bezpieczeństwa urządzeń emitujących promieniowanie laserowe (metoda pomiarowa bezpośrednia) Safety class of devices emitting laser radiation (direct measurement method)","reference":"Normy Procedura PB 07 Standards Procedure PB 07","norm_bases":["Normy Procedura PB 07 Standards Procedure PB 07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Urządzenia optoelektroniczne emitujące promieniowanie laserowe Optoelectronic devices emitting laser radiation Klasa bezpieczeństwa urządzeń emitujących promieniowanie laserowe (metoda pomiarowa bezpośrednia) Safety class of devices emitting laser radiation (direct measurement method) Normy Procedura PB 07 Standards Procedure PB 07 E Urzadzenia optoelektroniczne emitujace promieniowanie laserowe Optoelectronic devices emitting laser radiation Klasa bezpieczenstwa urzadzen emitujacych promieniowanie laserowe (metoda pomiarowa bezposrednia) Safety class of devices emitting laser radiation (direct measurement method) Normy Procedura PB 07 Standards Procedure PB 07","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"激光辐射发射装置的安全等级（直接测量法）Safety class of devices emitting laser radiation (direct measurement method)","search_zh":"E 发射激光辐射的光电装置 Optoelectronic devices emitting laser radiation 激光辐射发射装置的安全等级（直接测量法）Safety class of devices emitting laser radiation (direct measurement method) Normy Procedura PB 07 Standards Procedure PB 07","test_object_zh":"E 发射激光辐射的光电装置 Optoelectronic devices emitting laser radiation","search_en":"E Optoelectronic devices emitting laser radiation Safety class of devices emitting laser radiation (direct measurement method) Normy Procedura PB 07 Standards Procedure PB 07"},{"_id":"6a5a55eb9af9f73f3824fed0","lab_id":"69ad52a3de79e566650fb11f","country":"PL","accr_number":"AB 109","accr_body":"PCA","test_object":"E Materiał optyczny Optical material","test_object_en":"E Optical material","methodology":"Całkowita transmitancja spektralna (metoda pomiarowa bezpośrednia) Total spectral transmittance (direct measurement method)","methodology_en":"Total spectral transmittance (direct measurement method)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Całkowita transmitancja spektralna (metoda pomiarowa bezpośrednia) Total spectral transmittance (direct measurement method)","reference":"Normy Procedura PB 06 Standards Procedure PB 06","norm_bases":["Normy Procedura PB 06 Standards Procedure PB 06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Materiał optyczny Optical material Całkowita transmitancja spektralna (metoda pomiarowa bezpośrednia) Total spectral transmittance (direct measurement method) Normy Procedura PB 06 Standards Procedure PB 06 E Material optyczny Optical material Calkowita transmitancja spektralna (metoda pomiarowa bezposrednia) Total spectral transmittance (direct measurement method) Normy Procedura PB 06 Standards Procedure PB 06","categories":["materials"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"光谱总透射比（直接测量法）Total spectral transmittance (direct measurement method)","search_zh":"E 光学材料 Optical material 光谱总透射比（直接测量法）Total spectral transmittance (direct measurement method) Normy Procedura PB 06 Standards Procedure PB 06","test_object_zh":"E 光学材料 Optical material","search_en":"E Optical material Total spectral transmittance (direct measurement method) Normy Procedura PB 06 Standards Procedure PB 06"},{"_id":"6a5a55eb9af9f73f3824fed1","lab_id":"69ad52a3de79e566650fb11f","country":"PL","accr_number":"AB 109","accr_body":"PCA","test_object":"E Mierniki mocy / energii promieniowania laserowego Power/energy meters of laser radiation","test_object_en":"E Power/energy meters of laser radiation","methodology":"Współczynnik korekcyjny (metoda porównawcza oraz pomiar bezpośredni) Correction factor (comparative method and a direct measurement)","methodology_en":"Correction factor (comparative method and a direct measurement)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik korekcyjny (metoda porównawcza oraz pomiar bezpośredni) Correction factor (comparative method and a direct measurement)","reference":"Normy Procedura PB 05 Standards Procedure PB 05","norm_bases":["Normy Procedura PB 05 Standards Procedure PB 05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Mierniki mocy / energii promieniowania laserowego Power/energy meters of laser radiation Współczynnik korekcyjny (metoda porównawcza oraz pomiar bezpośredni) Correction factor (comparative method and a direct measurement) Normy Procedura PB 05 Standards Procedure PB 05 E Mierniki mocy / energii promieniowania laserowego Power/energy meters of laser radiation Wspolczynnik korekcyjny (metoda porownawcza oraz pomiar bezposredni) Correction factor (comparative method and a direct measurement) Normy Procedura PB 05 Standards Procedure PB 05","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"修正系数（比较法与直接测量）Correction factor (comparative method and a direct measurement)","search_zh":"E 激光辐射功率／能量计 Power/energy meters of laser radiation 修正系数（比较法与直接测量）Correction factor (comparative method and a direct measurement) Normy Procedura PB 05 Standards Procedure PB 05","test_object_zh":"E 激光辐射功率／能量计 Power/energy meters of laser radiation","search_en":"E Power/energy meters of laser radiation Correction factor (comparative method and a direct measurement) Normy Procedura PB 05 Standards Procedure PB 05"},{"_id":"6a5a55eb9af9f73f3824fed2","lab_id":"69ad52a3de79e566650fb11f","country":"PL","accr_number":"AB 109","accr_body":"PCA","test_object":"E Kamery TV, LLLTV, przyrządy noktowizyjne, inne TV and LLLTV cameras, night vision devices, other","test_object_en":"E TV and LLLTV cameras, night vision devices, other","methodology":"Funkcja minimalnego rozróżnialnego kontrastu oraz rozdzielczości przestrzennej (metoda pomiarowa bezpośrednia) Function of the minimum resolved contrast and spatial resolution (direct measurement method)","methodology_en":"Function of the minimum resolved contrast and spatial resolution (direct measurement method)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Funkcja minimalnego rozróżnialnego kontrastu oraz rozdzielczości przestrzennej (metoda pomiarowa bezpośrednia) Function of the minimum resolved contrast and spatial resolution (direct measurement method)","reference":"Normy Procedura PB 10 Standards Procedure PB 10","norm_bases":["Normy Procedura PB 10 Standards Procedure PB 10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Kamery TV, LLLTV, przyrządy noktowizyjne, inne TV and LLLTV cameras, night vision devices, other Funkcja minimalnego rozróżnialnego kontrastu oraz rozdzielczości przestrzennej (metoda pomiarowa bezpośrednia) Function of the minimum resolved contrast and spatial resolution (direct measurement method) Normy Procedura PB 10 Standards Procedure PB 10 E Kamery TV, LLLTV, przyrzady noktowizyjne, inne TV and LLLTV cameras, night vision devices, other Funkcja minimalnego rozroznialnego kontrastu oraz rozdzielczosci przestrzennej (metoda pomiarowa bezposrednia) Function of the minimum resolved contrast and spatial resolution (direct measurement method) Normy Procedura PB 10 Standards Procedure PB 10","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"最小可分辨对比度与空间分辨率函数（直接测量法）Function of the minimum resolved contrast and spatial resolution (direct measurement method)","search_zh":"E 电视摄像机、微光电视摄像机、夜视仪及其他 TV and LLLTV cameras, night vision devices, other 最小可分辨对比度与空间分辨率函数（直接测量法）Function of the minimum resolved contrast and spatial resolution (direct measurement method) Normy Procedura PB 10 Standards Procedure PB 10","test_object_zh":"E 电视摄像机、微光电视摄像机、夜视仪及其他 TV and LLLTV cameras, night vision devices, other","search_en":"E TV and LLLTV cameras, night vision devices, other Function of the minimum resolved contrast and spatial resolution (direct measurement method) Normy Procedura PB 10 Standards Procedure PB 10"},{"_id":"6a5a55eb9af9f73f3824fed3","lab_id":"69ad52a3de79e566650fb11f","country":"PL","accr_number":"AB 109","accr_body":"PCA","test_object":"E Kamery termowizyjne Thermal cameras","test_object_en":"Thermal cameras","methodology":"Moc równoważna szumom NETD (metoda pomiarowa bezpośrednia) Power equivalent to NETD (direct measurement method)","methodology_en":"Power equivalent to NETD (direct measurement method)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Moc równoważna szumom NETD (metoda pomiarowa bezpośrednia) Power equivalent to NETD (direct measurement method)","reference":"Normy Procedura PB 09 Standards Procedure PB 09","norm_bases":["Normy Procedura PB 09 Standards Procedure PB 09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Kamery termowizyjne Thermal cameras Moc równoważna szumom NETD (metoda pomiarowa bezpośrednia) Power equivalent to NETD (direct measurement method) Normy Procedura PB 09 Standards Procedure PB 09 E Kamery termowizyjne Thermal cameras Moc rownowazna szumom NETD (metoda pomiarowa bezposrednia) Power equivalent to NETD (direct measurement method) Normy Procedura PB 09 Standards Procedure PB 09","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"噪声等效功率 NETD（直接测量法）Power equivalent to NETD (direct measurement method)","search_zh":"E 热成像摄像机 Thermal cameras 噪声等效功率 NETD（直接测量法）Power equivalent to NETD (direct measurement method) Normy Procedura PB 09 Standards Procedure PB 09","test_object_zh":"E 热成像摄像机 Thermal cameras","search_en":"Thermal cameras Power equivalent to NETD (direct measurement method) Normy Procedura PB 09 Standards Procedure PB 09"},{"_id":"6a5a55eb9af9f73f3824fed4","lab_id":"69ad52a3de79e566650fb11f","country":"PL","accr_number":"AB 109","accr_body":"PCA","test_object":"E Kamery termowizyjne Thermal cameras","test_object_en":"Thermal cameras","methodology":"Funkcja minimalnej rozróżnialnej różnicy temperatur MRTD (metoda pomiarowa bezpośrednia) Function of the minimum resolved temperature difference MRTD (direct measurement method)","methodology_en":"Function of the minimum resolved temperature difference MRTD (direct measurement method)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Funkcja minimalnej rozróżnialnej różnicy temperatur MRTD (metoda pomiarowa bezpośrednia) Function of the minimum resolved temperature difference MRTD (direct measurement method)","reference":"Normy Procedura PB 09 Standards Procedure PB 09","norm_bases":["Normy Procedura PB 09 Standards Procedure PB 09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Kamery termowizyjne Thermal cameras Funkcja minimalnej rozróżnialnej różnicy temperatur MRTD (metoda pomiarowa bezpośrednia) Function of the minimum resolved temperature difference MRTD (direct measurement method) Normy Procedura PB 09 Standards Procedure PB 09 E Kamery termowizyjne Thermal cameras Funkcja minimalnej rozroznialnej roznicy temperatur MRTD (metoda pomiarowa bezposrednia) Function of the minimum resolved temperature difference MRTD (direct measurement method) Normy Procedura PB 09 Standards Procedure PB 09","categories":["other"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"最小可分辨温差函数 MRTD（直接测量法）Function of the minimum resolved temperature difference MRTD (direct measurement method)","search_zh":"E 热成像摄像机 Thermal cameras 最小可分辨温差函数 MRTD（直接测量法）Function of the minimum resolved temperature difference MRTD (direct measurement method) Normy Procedura PB 09 Standards Procedure PB 09","test_object_zh":"E 热成像摄像机 Thermal cameras","search_en":"Thermal cameras Function of the minimum resolved temperature difference MRTD (direct measurement method) Normy Procedura PB 09 Standards Procedure PB 09"},{"_id":"6a5a55eb9af9f73f3824fed5","lab_id":"69ad52a3de79e566650fb11f","country":"PL","accr_number":"AB 109","accr_body":"PCA","test_object":"E Kamery termowizyjne Thermal cameras","test_object_en":"Thermal cameras","methodology":"Zasięgi wykrycia, rozpoznania i identyfikacji urządzenia (z obliczeń) Detection, recognition and identification ranges of a device (from calculations)","methodology_en":"Detection, recognition and identification ranges of a device (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zasięgi wykrycia, rozpoznania i identyfikacji urządzenia (z obliczeń) Detection, recognition and identification ranges of a device (from calculations)","reference":"Normy Procedura PB 09 Standards Procedure PB 09","norm_bases":["Normy Procedura PB 09 Standards Procedure PB 09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Kamery termowizyjne Thermal cameras Zasięgi wykrycia, rozpoznania i identyfikacji urządzenia (z obliczeń) Detection, recognition and identification ranges of a device (from calculations) Normy Procedura PB 09 Standards Procedure PB 09 E Kamery termowizyjne Thermal cameras Zasiegi wykrycia, rozpoznania i identyfikacji urzadzenia (z obliczen) Detection, recognition and identification ranges of a device (from calculations) Normy Procedura PB 09 Standards Procedure PB 09","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"设备的探测、识别与辨认距离（计算得出）Detection, recognition and identification ranges of a device (from calculations)","search_zh":"E 热成像摄像机 Thermal cameras 设备的探测、识别与辨认距离（计算得出）Detection, recognition and identification ranges of a device (from calculations) Normy Procedura PB 09 Standards Procedure PB 09","test_object_zh":"E 热成像摄像机 Thermal cameras","search_en":"Thermal cameras Detection, recognition and identification ranges of a device (from calculations) Normy Procedura PB 09 Standards Procedure PB 09"},{"_id":"6a5a55eb9af9f73f3824fed6","lab_id":"69ad52a3de79e566650fb11f","country":"PL","accr_number":"AB 109","accr_body":"PCA","test_object":"E Kamery termowizyjne Thermal cameras","test_object_en":"Thermal cameras","methodology":"Pole widzenia FOV (metoda pomiarowa bezpośrednia) Field of view FOV (direct measurement method)","methodology_en":"Field of view FOV (direct measurement method)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pole widzenia FOV (metoda pomiarowa bezpośrednia) Field of view FOV (direct measurement method)","reference":"Normy Procedura PB 09 Standards Procedure PB 09","norm_bases":["Normy Procedura PB 09 Standards Procedure PB 09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Kamery termowizyjne Thermal cameras Pole widzenia FOV (metoda pomiarowa bezpośrednia) Field of view FOV (direct measurement method) Normy Procedura PB 09 Standards Procedure PB 09 E Kamery termowizyjne Thermal cameras Pole widzenia FOV (metoda pomiarowa bezposrednia) Field of view FOV (direct measurement method) Normy Procedura PB 09 Standards Procedure PB 09","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"视场角 FOV（直接测量法）Field of view FOV (direct measurement method)","search_zh":"E 热成像摄像机 Thermal cameras 视场角 FOV（直接测量法）Field of view FOV (direct measurement method) Normy Procedura PB 09 Standards Procedure PB 09","test_object_zh":"E 热成像摄像机 Thermal cameras","search_en":"Thermal cameras Field of view FOV (direct measurement method) Normy Procedura PB 09 Standards Procedure PB 09"},{"_id":"6a5a55eb9af9f73f3824fed7","lab_id":"69ad52a3de79e566650fb11f","country":"PL","accr_number":"AB 109","accr_body":"PCA","test_object":"E Materiały nieprzeźroczyste stałe Opaque solid materials","test_object_en":"E Opaque solid materials","methodology":"Reflektancja (metoda pomiarowa bezpośrednia) Reflectance (direct measurement method)","methodology_en":"Reflectance (direct measurement method)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Reflektancja (metoda pomiarowa bezpośrednia) Reflectance (direct measurement method)","reference":"Normy Procedura PB 08 Standards Procedure PB 08","norm_bases":["Normy Procedura PB 08 Standards Procedure PB 08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Materiały nieprzeźroczyste stałe Opaque solid materials Reflektancja (metoda pomiarowa bezpośrednia) Reflectance (direct measurement method) Normy Procedura PB 08 Standards Procedure PB 08 E Materialy nieprzezroczyste stale Opaque solid materials Reflektancja (metoda pomiarowa bezposrednia) Reflectance (direct measurement method) Normy Procedura PB 08 Standards Procedure PB 08","categories":["materials"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"反射比（直接测量法）Reflectance (direct measurement method)","search_zh":"E 不透明固体材料 Opaque solid materials 反射比（直接测量法）Reflectance (direct measurement method) Normy Procedura PB 08 Standards Procedure PB 08","test_object_zh":"E 不透明固体材料 Opaque solid materials","search_en":"E Opaque solid materials Reflectance (direct measurement method) Normy Procedura PB 08 Standards Procedure PB 08"},{"_id":"6a5a55eb9af9f73f3824fed8","lab_id":"69ad52a3de79e566650fb11f","country":"PL","accr_number":"AB 109","accr_body":"PCA","test_object":"E Materiały nieprzeźroczyste stałe Opaque solid materials","test_object_en":"E Opaque solid materials","methodology":"Reflektancja solarna (z obliczeń) Solar reflectance (from calculations)","methodology_en":"Solar reflectance (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Reflektancja solarna (z obliczeń) Solar reflectance (from calculations)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Materiały nieprzeźroczyste stałe Opaque solid materials Reflektancja solarna (z obliczeń) Solar reflectance (from calculations) E Materialy nieprzezroczyste stale Opaque solid materials Reflektancja solarna (z obliczen) Solar reflectance (from calculations)","categories":["materials"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"太阳光反射比（计算得出）Solar reflectance (from calculations)","search_zh":"E 不透明固体材料 Opaque solid materials 太阳光反射比（计算得出）Solar reflectance (from calculations)","test_object_zh":"E 不透明固体材料 Opaque solid materials","search_en":"E Opaque solid materials Solar reflectance (from calculations)"},{"_id":"6a5a55eb9af9f73f3824fed9","lab_id":"69ad52a3de79e566650fb11f","country":"PL","accr_number":"AB 109","accr_body":"PCA","test_object":"E Materiały nieprzeźroczyste stałe Opaque solid materials","test_object_en":"E Opaque solid materials","methodology":"Emisyjność względna (z obliczeń) Relative emissivity (from calculations)","methodology_en":"Relative emissivity (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisyjność względna (z obliczeń) Relative emissivity (from calculations)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Materiały nieprzeźroczyste stałe Opaque solid materials Emisyjność względna (z obliczeń) Relative emissivity (from calculations) E Materialy nieprzezroczyste stale Opaque solid materials Emisyjnosc wzgledna (z obliczen) Relative emissivity (from calculations)","categories":["materials"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"相对发射率（计算得出）Relative emissivity (from calculations)","search_zh":"E 不透明固体材料 Opaque solid materials 相对发射率（计算得出）Relative emissivity (from calculations)","test_object_zh":"E 不透明固体材料 Opaque solid materials","search_en":"E Opaque solid materials Relative emissivity (from calculations)"},{"_id":"6a5a55eb9af9f73f3824feda","lab_id":"69ad52a3de79e566650fb11f","country":"PL","accr_number":"AB 109","accr_body":"PCA","test_object":"E Materiały nieprzeźroczyste stałe Opaque solid materials","test_object_en":"E Opaque solid materials","methodology":"Współczynnik reflektancji solarnej SRI (z obliczeń) Solar reflectance index SRI (from calculations)","methodology_en":"Solar reflectance index SRI (from calculations)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Współczynnik reflektancji solarnej SRI (z obliczeń) Solar reflectance index SRI (from calculations)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"E Materiały nieprzeźroczyste stałe Opaque solid materials Współczynnik reflektancji solarnej SRI (z obliczeń) Solar reflectance index SRI (from calculations) E Materialy nieprzezroczyste stale Opaque solid materials Wspolczynnik reflektancji solarnej SRI (z obliczen) Solar reflectance index SRI (from calculations)","categories":["materials"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","methodology_zh":"太阳反射指数 SRI（计算得出）Solar reflectance index SRI (from calculations)","search_zh":"E 不透明固体材料 Opaque solid materials 太阳反射指数 SRI（计算得出）Solar reflectance index SRI (from calculations)","test_object_zh":"E 不透明固体材料 Opaque solid materials","search_en":"E Opaque solid materials Solar reflectance index SRI (from calculations)"}],"has_pdf":true}