🇵🇱 HENRYK SYREK PL
Environment
HENRYK SYREK is a laboratory accredited by PCA under number AB 1086 (Gorlice, Poland). Its accreditation scope covers 15 test methods in the following areas: Environment. Test objects include: Workplace environment − air, Workplace environment − indoor electric lighting, Workplace environment − noise.
At a glance
- Accreditation number: PCA AB 1086
- Methods in scope: 15
- Types of test objects: 3
- City: Gorlice, Poland
- Accreditation number
- AB 1086
- Accreditation body
- PCA
- Address
- ZAKŁAD HANDLOWO-USŁUGOWY „ATLEX”, LABORATORIUM BADAŃ ŚRODOWISKA PRACY, ul. Garbarska 18, 38-300 Gorlice
- City
- Gorlice, Poland
What this laboratory tests (3)
- Workplace environment − air — 5 methods
- Workplace environment − indoor electric lighting — 2 methods
- Workplace environment − noise — 2 methods
Accreditation scope — test methods (15)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment − indoor electric lighting | Illuminance Range: (5 – 5 000) lx Direct measurement method | PN-83/E-04040.03 | ||
| 2 | Workplace environment − indoor electric lighting | Illuminance uniformity (calculated) | |||
| 3 | Workplace environment − noise | A-weighted equivalent sound level A-weighted maximum sound level C-weighted peak sound level Range: (44 – 137) dB Direct measurement method | PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 - p. 10 i Strategię 3 - p. 11 | ||
| 4 | Workplace environment − noise | Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated) | |||
| 5 | Workplace environment − air | Sampling for occupational exposure assessment to: - dust agents – inhalable fraction – respirable fraction - inorganic substances – respirable fraction Personal dosimetry method | PN-Z-04008-7:2002 PN-Z-04008-7:2002/Az1:2004 | ||
| 6 | Workplace environment − air | Exposure index (calculated) | |||
| 7 | Workplace environment − air | Concentration of harmful dust agents - inhalable fraction: - Wood dust - Flour dust - Dusts not classified according to toxicity - Organic dusts of animal and plant origin except wood and flour dust Range: (0,5 − 45) mg/m³ Filtration-gravimetric method | PN-91/Z-04030.05 | ||
| 8 | Workplace environment − air | Concentration of harmful dust agents - respirable fraction: - Organic dusts of animal and plant origin except wood and flour dust - Diesel engine exhaust Range: (0,3 − 44) mg/m³ Filtration-gravimetric method | PN-91/Z-04030.06 | ||
| 9 | Workplace environment − air | Carbon monoxide concentration Range: (2,34 – 175,5) mg/m3 Electrochemical method | Instrukcja nr 01/2023 wersja 1 z dnia 03.01.2023 r. | ||
| 10 | I approve the change status | ||||
| 11 | HEAD | ||||
| 12 | OF THE ACCREDITATION DEPARTMENT | ||||
| 13 | OF EMISSION TESTING IN THE ENVIRONMENT | ||||
| 14 | MARCIN BEKAS | ||||
| 15 | dnia: 28.07.2025 r. | ||||
Reference standards (6)
Instrukcja nr 01/2023 wersja 1 z dnia 03.01.2023 r.
PN-83/E-04040.03
PN-91/Z-04030.05
PN-91/Z-04030.06
PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 - p. 10 i Strategię 3 - p. 11
PN-Z-04008-7:2002 PN-Z-04008-7:2002/Az1:2004