{"lab":{"_id":"69ad52a3de79e566650fb582","accr_number":"AB 1086","country":"PL","accr_body":"PCA","address":"ZAKŁAD HANDLOWO-USŁUGOWY „ATLEX”, LABORATORIUM BADAŃ ŚRODOWISKA PRACY, ul. Garbarska 18, 38-300 Gorlice","categories":["environment"],"city":"Gorlice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":15,"name":"HENRYK SYREK","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1086.pdf"],"scope_summary":"","search_text":"henryk syrek zakład handlowo-usługowy „atlex”, laboratorium badań środowiska pracy, ul. garbarska 18, 38-300 gorlice other environment pharma electronics metrology automotive","status":"active","updated_at":"2026-03-08T14:50:15.869Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:15.869Z","parse_date":"2026-07-17T16:18:51.558Z","parse_source":"m5-mistral-qa","email_confidence":"low","email_mx":true,"email_source":"http://www.atlex.com.pl/uslugi.html","needs_review":true,"review_reason":"e-mail niepewny (low) — zweryfikuj","fields_of_testing":[{"codes":"C/33","pl":"Badania chemiczne – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests and sampling - working environment (harmful factors - air)"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwie – hałas, oświetlenie)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, lighting)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"}],"issue":{"no":"16","date":"28.07.2025"},"map_coord":[49.656299,21.156557],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":10,"other":5},"category_scores":{"environment":6.67,"other":1.67},"has_zh":true},"methods":[{"_id":"6a5a55eb9af9f73f3824fe20","lab_id":"69ad52a3de79e566650fb582","country":"PL","accr_number":"AB 1086","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment − indoor electric lighting","methodology":"Natężenie oświetlenia Zakres: (5 – 5 000) lx Metoda pomiarowa bezpośrednia","methodology_en":"Illuminance Range: (5 – 5 000) lx Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie oświetlenia Zakres: (5 – 5 000) lx Metoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Natężenie oświetlenia Zakres: (5 – 5 000) lx Metoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy − oswietlenie elektryczne we wnetrzach Natezenie oswietlenia Zakres: (5 – 5 000) lx Metoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment − indoor electric lighting Illuminance Range: (5 – 5 000) lx Direct measurement method PN-83/E-04040.03","search_zh":"工作场所环境 − 室内电气照明 照度 范围：(5 – 5 000) lx 直接测量法 PN-83/E-04040.03","test_object_zh":"工作场所环境 − 室内电气照明","methodology_zh":"照度 范围：(5 – 5 000) lx 直接测量法"},{"_id":"6a5a55eb9af9f73f3824fe21","lab_id":"69ad52a3de79e566650fb582","country":"PL","accr_number":"AB 1086","accr_body":"PCA","test_object":"Środowisko pracy − oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment − indoor electric lighting","methodology":"Równomierność oświetlenia (z obliczeń)","methodology_en":"Illuminance uniformity (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) Srodowisko pracy − oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen)","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment − indoor electric lighting Illuminance uniformity (calculated)","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 − 室内电气照明 照度均匀度（计算值）","test_object_zh":"工作场所环境 − 室内电气照明"},{"_id":"6a5a55eb9af9f73f3824fe22","lab_id":"69ad52a3de79e566650fb582","country":"PL","accr_number":"AB 1086","accr_body":"PCA","test_object":"Środowisko pracy − hałas","test_object_en":"Workplace environment − noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C Zakres: (44 – 137) dB Metoda pomiarowa bezpośrednia","methodology_en":"A-weighted equivalent sound level A-weighted maximum sound level C-weighted peak sound level Range: (44 – 137) dB Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C Zakres: (44 – 137) dB Metoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 - p. 10 i Strategię 3 - p. 11","norm_bases":["PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 - p. 10 i Strategię 3 - p. 11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A Szczytowy poziom dźwięku C Zakres: (44 – 137) dB Metoda pomiarowa bezpośrednia PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 - p. 10 i Strategię 3 - p. 11 Srodowisko pracy − halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A Szczytowy poziom dzwieku C Zakres: (44 – 137) dB Metoda pomiarowa bezposrednia PN-N-01307:1994 PN-EN ISO 9612:2011 z wylaczeniem metod obejmujacych Strategie 2 - p. 10 i Strategie 3 - p. 11","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment − noise A-weighted equivalent sound level A-weighted maximum sound level C-weighted peak sound level Range: (44 – 137) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 - p. 10 i Strategię 3 - p. 11","search_zh":"工作环境 − 噪声 PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metod obejmujących Strategię 2 - p. 10 i Strategię 3 - p. 11","test_object_zh":"工作环境 − 噪声"},{"_id":"6a5a55eb9af9f73f3824fe23","lab_id":"69ad52a3de79e566650fb582","country":"PL","accr_number":"AB 1086","accr_body":"PCA","test_object":"Środowisko pracy − hałas","test_object_en":"Workplace environment − noise","methodology":"Poziom ekspozycji na hałas odniesiony do: - 8 godzinnego dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","methodology_en":"Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do: - 8 godzinnego dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − hałas Poziom ekspozycji na hałas odniesiony do: - 8 godzinnego dobowego wymiaru czasu pracy - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) Srodowisko pracy − halas Poziom ekspozycji na halas odniesiony do: - 8 godzinnego dobowego wymiaru czasu pracy - przecietnego tygodniowego wymiaru czasu pracy (z obliczen)","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment − noise Noise exposure level referred to: - the 8-hour daily working time - the average weekly working time (calculated)","methodology_zh":"噪声暴露级，折算至：- 8 小时工作日 - 平均每周工作时间（计算得出）","search_zh":"工作环境 − 噪声 噪声暴露级，折算至：- 8 小时工作日 - 平均每周工作时间（计算得出）","test_object_zh":"工作环境 − 噪声"},{"_id":"6a5a55eb9af9f73f3824fe24","lab_id":"69ad52a3de79e566650fb582","country":"PL","accr_number":"AB 1086","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na: - czynniki pyłowe – frakcja wdychalna – frakcja respirabilna - substancje nieorganiczne – frakcja respirabilna Metoda dozymetrii indywidualnej","methodology_en":"Sampling for occupational exposure assessment to: - dust agents – inhalable fraction – respirable fraction - inorganic substances – respirable fraction Personal dosimetry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na: - czynniki pyłowe – frakcja wdychalna – frakcja respirabilna - substancje nieorganiczne – frakcja respirabilna Metoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 PN-Z-04008-7:2002/Az1:2004","norm_bases":["PN-Z-04008-7:2002 PN-Z-04008-7:2002/Az1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Pobieranie próbek do oceny narażenia zawodowego na: - czynniki pyłowe – frakcja wdychalna – frakcja respirabilna - substancje nieorganiczne – frakcja respirabilna Metoda dozymetrii indywidualnej PN-Z-04008-7:2002 PN-Z-04008-7:2002/Az1:2004 Srodowisko pracy − powietrze Pobieranie probek do oceny narazenia zawodowego na: - czynniki pylowe – frakcja wdychalna – frakcja respirabilna - substancje nieorganiczne – frakcja respirabilna Metoda dozymetrii indywidualnej PN-Z-04008-7:2002 PN-Z-04008-7:2002/Az1:2004","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment − air Sampling for occupational exposure assessment to: - dust agents – inhalable fraction – respirable fraction - inorganic substances – respirable fraction Personal dosimetry method PN-Z-04008-7:2002 PN-Z-04008-7:2002/Az1:2004","search_zh":"工作环境 − 空气 PN-Z-04008-7:2002 PN-Z-04008-7:2002/Az1:2004","test_object_zh":"工作环境 − 空气"},{"_id":"6a5a55eb9af9f73f3824fe25","lab_id":"69ad52a3de79e566650fb582","country":"PL","accr_number":"AB 1086","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Wskaźnik narażenia (z obliczeń) Srodowisko pracy − powietrze Wskaznik narazenia (z obliczen)","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment − air Exposure index (calculated)","methodology_zh":"暴露指数（计算得出）","search_zh":"工作环境 − 空气 暴露指数（计算得出）","test_object_zh":"工作环境 − 空气"},{"_id":"6a5a55eb9af9f73f3824fe26","lab_id":"69ad52a3de79e566650fb582","country":"PL","accr_number":"AB 1086","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna: - Pyły drewna - Pyły mąki - Pyły niesklasyfikowane ze względu na toksyczność - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki Zakres: (0,5 − 45) mg/m³ Metoda filtracyjno-wagowa","methodology_en":"Concentration of harmful dust agents - inhalable fraction: - Wood dust - Flour dust - Dusts not classified according to toxicity - Organic dusts of animal and plant origin except wood and flour dust Range: (0,5 − 45) mg/m³ Filtration-gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna: - Pyły drewna - Pyły mąki - Pyły niesklasyfikowane ze względu na toksyczność - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki Zakres: (0,5 − 45) mg/m³ Metoda filtracyjno-wagowa","reference":"PN-91/Z-04030.05","norm_bases":["PN-91/Z-04030.05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna: - Pyły drewna - Pyły mąki - Pyły niesklasyfikowane ze względu na toksyczność - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki Zakres: (0,5 − 45) mg/m³ Metoda filtracyjno-wagowa PN-91/Z-04030.05 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna: - Pyly drewna - Pyly maki - Pyly niesklasyfikowane ze wzgledu na toksycznosc - Pyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki Zakres: (0,5 − 45) mg/m³ Metoda filtracyjno-wagowa PN-91/Z-04030.05","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment − air Concentration of harmful dust agents - inhalable fraction: - Wood dust - Flour dust - Dusts not classified according to toxicity - Organic dusts of animal and plant origin except wood and flour dust Range: (0,5 − 45) mg/m³ Filtration-gravimetric method PN-91/Z-04030.05","search_zh":"工作环境 − 空气 PN-91/Z-04030.05","test_object_zh":"工作环境 − 空气"},{"_id":"6a5a55eb9af9f73f3824fe27","lab_id":"69ad52a3de79e566650fb582","country":"PL","accr_number":"AB 1086","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna: - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Spaliny silnika Diesla Zakres: (0,3 − 44) mg/m³ Metoda filtracyjno-wagowa","methodology_en":"Concentration of harmful dust agents - respirable fraction: - Organic dusts of animal and plant origin except wood and flour dust - Diesel engine exhaust Range: (0,3 − 44) mg/m³ Filtration-gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna: - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Spaliny silnika Diesla Zakres: (0,3 − 44) mg/m³ Metoda filtracyjno-wagowa","reference":"PN-91/Z-04030.06","norm_bases":["PN-91/Z-04030.06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna: - Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki - Spaliny silnika Diesla Zakres: (0,3 − 44) mg/m³ Metoda filtracyjno-wagowa PN-91/Z-04030.06 Srodowisko pracy − powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja respirabilna: - Pyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki - Spaliny silnika Diesla Zakres: (0,3 − 44) mg/m³ Metoda filtracyjno-wagowa PN-91/Z-04030.06","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment − air Concentration of harmful dust agents - respirable fraction: - Organic dusts of animal and plant origin except wood and flour dust - Diesel engine exhaust Range: (0,3 − 44) mg/m³ Filtration-gravimetric method PN-91/Z-04030.06","search_zh":"工作环境 − 空气 PN-91/Z-04030.06","test_object_zh":"工作环境 − 空气"},{"_id":"6a5a55eb9af9f73f3824fe28","lab_id":"69ad52a3de79e566650fb582","country":"PL","accr_number":"AB 1086","accr_body":"PCA","test_object":"Środowisko pracy − powietrze","test_object_en":"Workplace environment − air","methodology":"Stężenie tlenku węgla Zakres: (2,34 – 175,5) mg/m3 Metoda elektrochemiczna","methodology_en":"Carbon monoxide concentration Range: (2,34 – 175,5) mg/m3 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenku węgla Zakres: (2,34 – 175,5) mg/m3 Metoda elektrochemiczna","reference":"Instrukcja nr 01/2023 wersja 1 z dnia 03.01.2023 r.","norm_bases":["Instrukcja nr 01/2023 wersja 1 z dnia 03.01.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy − powietrze Stężenie tlenku węgla Zakres: (2,34 – 175,5) mg/m3 Metoda elektrochemiczna Instrukcja nr 01/2023 wersja 1 z dnia 03.01.2023 r. Srodowisko pracy − powietrze Stezenie tlenku wegla Zakres: (2,34 – 175,5) mg/m3 Metoda elektrochemiczna Instrukcja nr 01/2023 wersja 1 z dnia 03.01.2023 r.","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment − air Carbon monoxide concentration Range: (2,34 – 175,5) mg/m3 Electrochemical method Instrukcja nr 01/2023 wersja 1 z dnia 03.01.2023 r.","search_zh":"工作环境 − 空气 Instrukcja nr 01/2023 wersja 1 z dnia 03.01.2023 r.","test_object_zh":"工作环境 − 空气"},{"_id":"6a5a55eb9af9f73f3824fe29","lab_id":"69ad52a3de79e566650fb582","country":"PL","accr_number":"AB 1086","accr_body":"PCA","test_object":"","test_object_en":null,"methodology":"Zatwierdzam status zmian","methodology_en":"I approve the change status","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zatwierdzam status zmian","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Zatwierdzam status zmian Zatwierdzam status zmian","categories":["other"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"I approve the change status"},{"_id":"6a5a55eb9af9f73f3824fe2a","lab_id":"69ad52a3de79e566650fb582","country":"PL","accr_number":"AB 1086","accr_body":"PCA","test_object":"","test_object_en":null,"methodology":"KIEROWNIK","methodology_en":"HEAD","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"KIEROWNIK","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"KIEROWNIK KIEROWNIK","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"HEAD"},{"_id":"6a5a55eb9af9f73f3824fe2b","lab_id":"69ad52a3de79e566650fb582","country":"PL","accr_number":"AB 1086","accr_body":"PCA","test_object":"","test_object_en":null,"methodology":"DZIAŁU AKREDYTACJI","methodology_en":"OF THE ACCREDITATION DEPARTMENT","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"DZIAŁU AKREDYTACJI","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"DZIAŁU AKREDYTACJI DZIALU AKREDYTACJI","categories":["other"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"OF THE ACCREDITATION DEPARTMENT"},{"_id":"6a5a55eb9af9f73f3824fe2c","lab_id":"69ad52a3de79e566650fb582","country":"PL","accr_number":"AB 1086","accr_body":"PCA","test_object":"","test_object_en":null,"methodology":"BADAŃ EMISJI W ŚRODOWISKU","methodology_en":"OF EMISSION TESTING IN THE ENVIRONMENT","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"BADAŃ EMISJI W ŚRODOWISKU","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"BADAŃ EMISJI W ŚRODOWISKU BADAN EMISJI W SRODOWISKU","categories":["environment"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"OF EMISSION TESTING IN THE ENVIRONMENT"},{"_id":"6a5a55eb9af9f73f3824fe2d","lab_id":"69ad52a3de79e566650fb582","country":"PL","accr_number":"AB 1086","accr_body":"PCA","test_object":"","test_object_en":null,"methodology":"MARCIN BEKAS","methodology_en":"MARCIN BEKAS","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"MARCIN BEKAS","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"MARCIN BEKAS MARCIN BEKAS","categories":["other"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"MARCIN BEKAS"},{"_id":"6a5a55eb9af9f73f3824fe2e","lab_id":"69ad52a3de79e566650fb582","country":"PL","accr_number":"AB 1086","accr_body":"PCA","test_object":"","test_object_en":null,"methodology":"dnia: 28.07.2025 r.","methodology_en":"dnia: 28.07.2025 r.","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"dnia: 28.07.2025 r.","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"dnia: 28.07.2025 r. dnia: 28.07.2025 r.","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"dnia: 28.07.2025 r."}],"has_pdf":true}