🇵🇱 ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o. w OŁAWIE PL

PCA AB 1081 • Oława, Poland • 25 methods

Water & wastewaterMicrobiology

ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o. w OŁAWIE is a laboratory accredited by PCA under number AB 1081 (Oława, Poland). Its accreditation scope covers 25 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Wastewater, Water, water intended for human consumption, wastewater, Water intended for human consumption. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, MPN method (Colilert 18 test).

At a glance

  • Accreditation number: PCA AB 1081
  • Methods in scope: 25
  • Types of test objects: 4
  • Techniques used: 11
  • City: Oława, Poland
Accreditation number
AB 1081
Accreditation body
PCA
Address
ul. 3 Maja 30, 55-200 Oława, LABORATORIUM WODNO-ŚCIEKOWE, ul. Rybacka 31, 55-200 Oława
City
Oława, Poland

What this laboratory tests (4)

Analytical techniques used (11)

Laboratory locations

Accreditation scope — test methods (25)

No. Test object Methodology / Parameters Technique Reference document
Water and Wastewater Laboratory
1 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
2 Water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt od 4.4.3. do 4.4.6.
3 Water, water intended for human consumption Total iron concentration
Range (0,10 – 5,0) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
4 Water, water intended for human consumption Manganese concentration
Range (0,030 – 1,0) mg/l
Spectrophotometric method PN-92/C-04590.03
5 Water, water intended for human consumption Chloride concentration
Range (6 – 150) mg/l
Titrimetric method PN-ISO 9297:1994
6 Water, water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (0,06 – 6,00) mmol/l
Titrimetric method P N - ISO 6059:1999
7 Water, water intended for human consumption Electrical conductivity
Range (100 – 3000) μS/cm
Conductometric method PN-EN 27888:1999
8 Water, water intended for human consumption Turbidity
Range (0,5 – 10) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
9 Water, water intended for human consumption Escherichia coli count Membrane filtration method PN-EN-ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04
10 Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN-ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04
11 Water, water intended for human consumption Most probable number, Escherichia coli MPN method (Colilert 18 test) PN-EN-ISO 9308-2:2014-06
12 Water, water intended for human consumption Most probable number of coliform bacteria MPN method (Colilert 18 test) PN-EN-ISO 9308-2:2014-06
13 Water, water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
14 Water, water intended for human consumption Total viable count at 22 °C Plate method (pour plate) P N -EN ISO 6222:2004
15 Water, water intended for human consumption Total viable count at 36 °C Plate method (pour plate) P N -EN ISO 6222:2004
16 Wastewater Sampling for chemical testing and physical properties Manual method; Automatic method PN-ISO 5667-10:2021-11
17 Wastewater Chemical oxygen demand - COD
Range (6 – 7000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
18 Wastewater Biochemical oxygen demand
BOD5 Range (3 – 2000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12
19 Wastewater Total suspended solids (TSS)
Range (2 – 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
20 Wastewater Total nitrogen concentration
Range (1 – 200) mg/l
Spectrophotometric method PB-04 wyd. III z 11.04.2016 r. | na podstawie testu kuwetowego Hach Lange nr LCK 138, LCK 238 i LCK 338
21 Wastewater Total phosphorus concentration
Range (0,06 – 20) mg/l
Spectrophotometric method PB-09 wyd. III z 11.04.2016 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 348, LCK 349 i LCK 350
22 Water, water intended for human consumption, wastewater Ammonium nitrogen concentration
Range (0,08 – 100) mg/l Ammonium ion concentration Range (0,1 – 128,8) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
23 Water, water intended for human consumption, wastewater Nitrite nitrogen concentration
Range (0,036 – 1) mg/l Nitrite concentration Range (0,12 – 3,29) mg/l
Spectrophotometric method PN-EN 26777:1999
24 Water, water intended for human consumption, wastewater Nitrate nitrogen concentration
Range (0,04 – 11) mg/l Nitrate concentration Range (0,18 – 48,7) mg/l
Spectrophotometric method PN-82/C-04576.08
25 Water, water intended for human consumption, wastewater pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012

Reference standards (25)

P N - ISO 6059:1999
P N -EN ISO 6222:2004
PB-04 wyd. III z 11.04.2016 r.
PB-09 wyd. III z 11.04.2016 r.
PN-82/C-04576.08
PN-92/C-04590.03
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem pkt od 4.4.3. do 4.4.6.
PN-EN ISO 5815-1:2019-12
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12/A1:2017-04
PN-EN-ISO 9308-1:2014-12
PN-EN-ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9297:1994
na podstawie testu kuwetowego Hach Lange Nr LCK 348, LCK 349 i LCK 350