{"lab":{"_id":"69ad52a3de79e566650fb57c","accr_number":"AB 1081","country":"PL","accr_body":"PCA","address":"ul. 3 Maja 30, 55-200 Oława, LABORATORIUM WODNO-ŚCIEKOWE, ul. Rybacka 31, 55-200 Oława","categories":["water","microbiology"],"city":"Oława","imported_at":"2026-03-08T10:42:43.265Z","methods_count":25,"name":"ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o. w OŁAWIE","parse_status":"parsed","parse_version":2,"pdf_files":["AB_1081.pdf"],"scope_summary":"","search_text":"zakład wodociągów i kanalizacji sp. z o.o. w oławie ul. 3 maja 30, 55-200 oława, laboratorium wodno-ściekowe, ul. rybacka 31, 55-200 oława water microbiology other pharma electronics automotive","status":"active","updated_at":"2026-03-08T14:50:15.666Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:56:41.156Z","parse_date":"2026-08-13T07:56:41.156Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://zwik.olawa.pl/kontakt/","fields_of_testing":[{"codes":"C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of drinking water, sewage"},{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling of drinking water"},{"codes":"K/28","pl":"Badania mikrobiologiczne wody","en":"Microbiological tests of water"},{"codes":"N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of drinking water, sewage"},{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"}],"issue":{"no":"17","date":"22.05.2026"},"map_coord":[50.932516,17.308656],"map_geo":"nominatim-street","lab_locations":[{"name":"ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o. w OŁAWIE","address":"ul. 3 Maja 30","city":null,"postal":null},{"name":"LABORATORIUM WODNO-ŚCIEKOWE","address":"ul. Rybacka 31","city":null,"postal":null},{"name":"Laboratorium Wodno – Ściekowe","address":"ul. Rybacka 31, 55-200 Oława","city":"Oława","postal":"55-200"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/ede65b72a9a65d7df74e9c95e8067723/AB%201081.pdf","has_zh":true,"has_en":true,"category_counts":{"water":25,"microbiology":5},"category_scores":{"water":20.83,"microbiology":0.83},"lab_locations_zh":[{"name":"ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o.o. w OŁAWIE","address":"ul. 3 Maja 30","city":null,"postal":null},{"name":"LABORATORIUM WODNO-ŚCIEKOWE","address":"ul. Rybacka 31","city":null,"postal":null},{"name":"水与污水实验室","address":"ul. Rybacka 31, 55-200 Oława","city":"Oława","postal":"55-200"}]},"methods":[{"_id":"6a7d78b90636ba417e41a198","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 水与污水实验室 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing Water and Wastewater Laboratory PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption"},{"_id":"6a7d78b90636ba417e41a199","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt od 4.4.3. do 4.4.6.","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt od 4.4.3. do 4.4.6."],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt od 4.4.3. do 4.4.6. Woda, woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt od 4.4.3. do 4.4.6.","categories":["water","microbiology"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水 微生物检测用样品采集 水与污水实验室 PN-EN ISO 19458:2007 z wyłączeniem pkt od 4.4.3. do 4.4.6.","test_object_zh":"水、生活饮用水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Sampling for microbiological testing","search_en":"Water, water intended for human consumption Sampling for microbiological testing Water and Wastewater Laboratory PN-EN ISO 19458:2007 z wyłączeniem pkt od 4.4.3. do 4.4.6.","test_object_en":"Water, water intended for human consumption"},{"_id":"6a7d78b90636ba417e41a19a","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,10 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,10 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,10 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,10 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 5,0) mg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 水与污水实验室 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,10 – 5,0) mg/l"}],"search_en":"Water, water intended for human consumption Total iron concentration Spectrophotometric method Water and Wastewater Laboratory Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption"},{"_id":"6a7d78b90636ba417e41a19b","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,030 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,030 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590.03","norm_bases":["PN-92/C-04590.03"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu\nZakres (0,030 – 1,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04590.03 Woda, woda do spozycia przez ludzi Stezenie manganu\nZakres (0,030 – 1,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04590.03","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,030 – 1,0) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 水与污水实验室 范围 PN-92/C-04590.03","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,030 – 1,0) mg/l"}],"search_en":"Water, water intended for human consumption Manganese concentration Spectrophotometric method Water and Wastewater Laboratory Range PN-92/C-04590.03","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption"},{"_id":"6a7d78b90636ba417e41a19c","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(6 – 150) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (6 – 150) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chlorków\nZakres (6 – 150) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi Stezenie chlorkow\nZakres (6 – 150) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(6 – 150) mg/l"}],"search_zh":"水、生活饮用水 氯化物浓度 滴定法 水与污水实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(6 – 150) mg/l"}],"search_en":"Water, water intended for human consumption Chloride concentration Titrimetric method Water and Wastewater Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption"},{"_id":"6a7d78b90636ba417e41a19d","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(0,06 – 6,00) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (0,06 – 6,00) mmol/l\nMetoda miareczkowa","reference":"P N - ISO 6059:1999","norm_bases":["P N - ISO 6059:1999"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (0,06 – 6,00) mmol/l\nMetoda miareczkowa P N - ISO 6059:1999 Woda, woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (0,06 – 6,00) mmol/l\nMetoda miareczkowa P N - ISO 6059:1999","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(0,06 – 6,00) mmol/l"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 水与污水实验室 范围 P N - ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(0,06 – 6,00) mmol/l"}],"search_en":"Water, water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Water and Wastewater Laboratory Range P N - ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption"},{"_id":"6a7d78b90636ba417e41a19e","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 – 3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (100 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (100 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 3000) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 水与污水实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 – 3000) μS/cm"}],"search_en":"Water, water intended for human consumption Electrical conductivity Conductometric method Water and Wastewater Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, water intended for human consumption"},{"_id":"6a7d78b90636ba417e41a19f","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,5 – 10) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,5 – 10) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,5 – 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,5 – 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,5 – 10) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 水与污水实验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,5 – 10) NTU"}],"search_en":"Water, water intended for human consumption Turbidity Nephelometric method Water and Wastewater Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, water intended for human consumption"},{"_id":"6a7d78b90636ba417e41a1a0","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN-ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN-ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN-ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda, woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN-ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 水与污水实验室 PN-EN-ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Escherichia coli count","search_en":"Water, water intended for human consumption Escherichia coli count Membrane filtration method Water and Wastewater Laboratory PN-EN-ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption"},{"_id":"6a7d78b90636ba417e41a1a1","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN-ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN-ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN-ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda, woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN-ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 水与污水实验室 PN-EN-ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Coliform bacteria count","search_en":"Water, water intended for human consumption Coliform bacteria count Membrane filtration method Water and Wastewater Laboratory PN-EN-ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption"},{"_id":"6a7d78b90636ba417e41a1a2","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","parameters":[],"technique":"Metoda NPL (test Colilert 18)","techniques":["Metoda NPL (test Colilert 18)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL (test Colilert 18)","reference":"PN-EN-ISO 9308-2:2014-06","norm_bases":["PN-EN-ISO 9308-2:2014-06"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL (test Colilert 18) PN-EN-ISO 9308-2:2014-06 Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL (test Colilert 18) PN-EN-ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） 最可能数法（Colilert 18 试验） 水与污水实验室 PN-EN-ISO 9308-2:2014-06","technique_zh":"最可能数法（Colilert 18 试验）","test_object_zh":"水、生活饮用水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Most probable number, Escherichia coli","search_en":"Water, water intended for human consumption Most probable number, Escherichia coli MPN method (Colilert 18 test) Water and Wastewater Laboratory PN-EN-ISO 9308-2:2014-06","technique_en":"MPN method (Colilert 18 test)","test_object_en":"Water, water intended for human consumption"},{"_id":"6a7d78b90636ba417e41a1a3","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL (test Colilert 18)","techniques":["Metoda NPL (test Colilert 18)"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL (test Colilert 18)","reference":"PN-EN-ISO 9308-2:2014-06","norm_bases":["PN-EN-ISO 9308-2:2014-06"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL (test Colilert 18) PN-EN-ISO 9308-2:2014-06 Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL (test Colilert 18) PN-EN-ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"水、生活饮用水 大肠菌群最可能数（MPN） 最可能数法（Colilert 18 试验） 水与污水实验室 PN-EN-ISO 9308-2:2014-06","technique_zh":"最可能数法（Colilert 18 试验）","test_object_zh":"水、生活饮用水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Most probable number of coliform bacteria","search_en":"Water, water intended for human consumption Most probable number of coliform bacteria MPN method (Colilert 18 test) Water and Wastewater Laboratory PN-EN-ISO 9308-2:2014-06","technique_en":"MPN method (Colilert 18 test)","test_object_en":"Water, water intended for human consumption"},{"_id":"6a7d78b90636ba417e41a1a4","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Liczba enterokoków","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Liczba enterokoków\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, woda do spozycia przez ludzi Liczba enterokokow\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"肠球菌计数","search_zh":"水、生活饮用水 肠球菌计数 膜过滤法 水与污水实验室 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Enterococci count","search_en":"Water, water intended for human consumption Enterococci count Membrane filtration method Water and Wastewater Laboratory PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water, water intended for human consumption"},{"_id":"6a7d78b90636ba417e41a1a5","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 22 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"P N -EN ISO 6222:2004","norm_bases":["P N -EN ISO 6222:2004"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny) P N -EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 °C\nMetoda plytkowa (posiew wglebny) P N -EN ISO 6222:2004","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"22 °C 微生物总数","search_zh":"水、生活饮用水 22 °C 微生物总数 平板法（倾注培养） 水与污水实验室 P N -EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Total viable count at 22 °C","search_en":"Water, water intended for human consumption Total viable count at 22 °C Plate method (pour plate) Water and Wastewater Laboratory P N -EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, water intended for human consumption"},{"_id":"6a7d78b90636ba417e41a1a6","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w 36 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"P N -EN ISO 6222:2004","norm_bases":["P N -EN ISO 6222:2004"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny) P N -EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36 °C\nMetoda plytkowa (posiew wglebny) P N -EN ISO 6222:2004","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"36 °C 微生物总数","search_zh":"水、生活饮用水 36 °C 微生物总数 平板法（倾注培养） 水与污水实验室 P N -EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Total viable count at 36 °C","search_en":"Water, water intended for human consumption Total viable count at 36 °C Plate method (pour plate) Water and Wastewater Laboratory P N -EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, water intended for human consumption"},{"_id":"6a7d78b90636ba417e41a1a7","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i właściwości fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i właściwości fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i właściwości fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i wlasciwosci fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"化学检测与物理性能检测用样品采集","search_zh":"污水 化学检测与物理性能检测用样品采集 手动法；自动法 水与污水实验室 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Sampling for chemical testing and physical properties","search_en":"Wastewater Sampling for chemical testing and physical properties Manual method; Automatic method Water and Wastewater Laboratory PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater"},{"_id":"6a7d78b90636ba417e41a1a8","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT","parameters":[{"name":"Zakres","range":"(6 – 7000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (6 – 7000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (6 – 7000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu - ChZT\nZakres (6 – 7000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"化学需氧量 ChZT（COD）","parameters_zh":[{"name":"范围","range":"(6 – 7000) mg/l O2"}],"search_zh":"污水 化学需氧量 ChZT（COD） 分光光度法 水与污水实验室 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Chemical oxygen demand - COD","parameters_en":[{"name":"Range","range":"(6 – 7000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand - COD Spectrophotometric method Water and Wastewater Laboratory Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater"},{"_id":"6a7d78b90636ba417e41a1a9","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 – 2000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 2000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 2000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 2000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 – 2000) mg/l O2"}],"search_zh":"污水 生化需氧量 光学法 水与污水实验室 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"污水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 – 2000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand Optical method Water and Wastewater Laboratory BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Wastewater"},{"_id":"6a7d78b90636ba417e41a1aa","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2 – 2000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 水与污水实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2 – 2000) mg/l"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Water and Wastewater Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater"},{"_id":"6a7d78b90636ba417e41a1ab","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(1 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (1 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PB-04 wyd. III z 11.04.2016 r. | na podstawie testu kuwetowego Hach Lange nr LCK 138, LCK 238 i LCK 338","norm_bases":["PB-04 wyd. III z 11.04.2016 r.","na podstawie testu kuwetowego Hach Lange nr LCK 138, LCK 238 i LCK 338"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (1 – 200) mg/l\nMetoda spektrofotometryczna PB-04 wyd. III z 11.04.2016 r. | na podstawie testu kuwetowego Hach Lange nr LCK 138, LCK 238 i LCK 338 Scieki Stezenie azotu ogolnego\nZakres (1 – 200) mg/l\nMetoda spektrofotometryczna PB-04 wyd. III z 11.04.2016 r. | na podstawie testu kuwetowego Hach Lange nr LCK 138, LCK 238 i LCK 338","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1 – 200) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 水与污水实验室 范围 PB-04 wyd. III z 11.04.2016 r. | na podstawie testu kuwetowego Hach Lange nr LCK 138, LCK 238 i LCK 338","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(1 – 200) mg/l"}],"search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Water and Wastewater Laboratory Range PB-04 wyd. III z 11.04.2016 r. | na podstawie testu kuwetowego Hach Lange nr LCK 138, LCK 238 i LCK 338","technique_en":"Spectrophotometric method","test_object_en":"Wastewater"},{"_id":"6a7d78b90636ba417e41a1ac","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,06 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,06 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PB-09 wyd. III z 11.04.2016 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 348, LCK 349 i LCK 350","norm_bases":["PB-09 wyd. III z 11.04.2016 r.","na podstawie testu kuwetowego Hach Lange Nr LCK 348, LCK 349 i LCK 350"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,06 – 20) mg/l\nMetoda spektrofotometryczna PB-09 wyd. III z 11.04.2016 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 348, LCK 349 i LCK 350 Scieki Stezenie fosforu ogolnego\nZakres (0,06 – 20) mg/l\nMetoda spektrofotometryczna PB-09 wyd. III z 11.04.2016 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 348, LCK 349 i LCK 350","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,06 – 20) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 水与污水实验室 范围 PB-09 wyd. III z 11.04.2016 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 348, LCK 349 i LCK 350","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,06 – 20) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Water and Wastewater Laboratory Range PB-09 wyd. III z 11.04.2016 r. | na podstawie testu kuwetowego Hach Lange Nr LCK 348, LCK 349 i LCK 350","technique_en":"Spectrophotometric method","test_object_en":"Wastewater"},{"_id":"6a7d78b90636ba417e41a1ad","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,08 – 100) mg/l"},{"name":"Stężenie jonu amonowego"},{"name":"Zakres","range":"(0,1 – 128,8) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,08 – 100) mg/l\nStężenie jonu amonowego\nZakres (0,1 – 128,8) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu amonowego\nZakres:\nZakres (0,08 – 100) mg/l\nStężenie jonu amonowego\nZakres (0,1 – 128,8) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, woda do spozycia przez ludzi, scieki Stezenie azotu amonowego\nZakres:\nZakres (0,08 – 100) mg/l\nStezenie jonu amonowego\nZakres (0,1 – 128,8) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,08 – 100) mg/l"},{"name":"铵离子浓度"},{"name":"范围","range":"(0,1 – 128,8) mg/l"}],"search_zh":"水、生活饮用水、污水 氨氮浓度 分光光度法 水与污水实验室 范围 铵离子浓度 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,08 – 100) mg/l"},{"name":"Ammonium ion concentration"},{"name":"Range","range":"(0,1 – 128,8) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Ammonium nitrogen concentration Spectrophotometric method Water and Wastewater Laboratory Range Ammonium ion concentration Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater"},{"_id":"6a7d78b90636ba417e41a1ae","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,036 – 1) mg/l"},{"name":"Stężenie azotynów"},{"name":"Zakres","range":"(0,12 – 3,29) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres:\nZakres (0,036 – 1) mg/l\nStężenie azotynów\nZakres (0,12 – 3,29) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu azotynowego\nZakres:\nZakres (0,036 – 1) mg/l\nStężenie azotynów\nZakres (0,12 – 3,29) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi, scieki Stezenie azotu azotynowego\nZakres:\nZakres (0,036 – 1) mg/l\nStezenie azotynow\nZakres (0,12 – 3,29) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,036 – 1) mg/l"},{"name":"亚硝酸盐浓度"},{"name":"范围","range":"(0,12 – 3,29) mg/l"}],"search_zh":"水、生活饮用水、污水 亚硝态氮浓度 分光光度法 水与污水实验室 范围 亚硝酸盐浓度 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,036 – 1) mg/l"},{"name":"Nitrite concentration"},{"name":"Range","range":"(0,12 – 3,29) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Nitrite nitrogen concentration Spectrophotometric method Water and Wastewater Laboratory Range Nitrite concentration Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater"},{"_id":"6a7d78b90636ba417e41a1af","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,04 – 11) mg/l"},{"name":"Stężenie azotanów"},{"name":"Zakres","range":"(0,18 – 48,7) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres:\nZakres (0,04 – 11) mg/l\nStężenie azotanów\nZakres (0,18 – 48,7) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie azotu azotanowego\nZakres:\nZakres (0,04 – 11) mg/l\nStężenie azotanów\nZakres (0,18 – 48,7) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, woda do spozycia przez ludzi, scieki Stezenie azotu azotanowego\nZakres:\nZakres (0,04 – 11) mg/l\nStezenie azotanow\nZakres (0,18 – 48,7) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 11) mg/l"},{"name":"硝酸盐浓度"},{"name":"范围","range":"(0,18 – 48,7) mg/l"}],"search_zh":"水、生活饮用水、污水 硝态氮浓度 分光光度法 水与污水实验室 范围 硝酸盐浓度 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,04 – 11) mg/l"},{"name":"Nitrate concentration"},{"name":"Range","range":"(0,18 – 48,7) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Nitrate nitrogen concentration Spectrophotometric method Water and Wastewater Laboratory Range Nitrate concentration Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater"},{"_id":"6a7d78b90636ba417e41a1b0","lab_id":"69ad52a3de79e566650fb57c","country":"PL","accr_number":"AB 1081","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Wodno – Ściekowe","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi, scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_zh":"水与污水实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、生活饮用水、污水 pH 值 电位法 水与污水实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、污水","lab_section_en":"Water and Wastewater Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water, water intended for human consumption, wastewater pH Potentiometric method Water and Wastewater Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, water intended for human consumption, wastewater"}],"has_pdf":true}