🇵🇱 ARCELORMITTAL POLAND S.A. ODDZIAŁ W ZDZIESZOWICACH PL
Water & wastewaterEnvironment
ARCELORMITTAL POLAND S.A. ODDZIAŁ W ZDZIESZOWICACH is a laboratory accredited by PCA under number AB 1069 (Zdzieszowice, Poland). Its accreditation scope covers 33 test methods in the following areas: Water & wastewater, Environment. Test objects include: Water, wastewater, Workplace environment – air, Wastewater, Workplace environment – cold microclimate. Most frequently used techniques: Spectrophotometric method, Gravimetric method, Direct measurement method.
At a glance
- Accreditation number: PCA AB 1069
- Methods in scope: 33
- Types of test objects: 8
- Techniques used: 13
- City: Zdzieszowice, Poland
- Accreditation number
- AB 1069
- Accreditation body
- PCA
- Address
- LABORATORIUM POMIARÓW ŚRODOWISKOWYCH, ul. Powstańców Śląskich 1, 47-330 Zdzieszowice
- City
- Zdzieszowice, Poland
What this laboratory tests (8)
- Water, wastewater — 16 methods
- Workplace environment – air — 7 methods
- Wastewater — 2 methods
- Workplace environment – cold microclimate — 2 methods
- Workplace environment – hot microclimate — 2 methods
- Workplace environment – noise — 2 methods
- Waste gases — 1 method
- Workplace environment - air samples — 1 method
Analytical techniques used (13)
- Spectrophotometric method — 5 methods
- Gravimetric method — 4 methods
- Direct measurement method — 3 methods
- Electrochemical method — 3 methods
- Titrimetric method — 3 methods
- Fourier transform infrared spectrometry (FT- IR) — 1 method
- Gas chromatography with flame ionization detection (GC-FID) — 1 method
- Gas chromatography with flame ionization detection (GC–FID) — 1 method
- Manual method — 1 method
- Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i z detekcją płomieniowo-jonizacyjną (HS-GC–FID) — 1 method
- Non-dispersive infrared spectrometry (NDIR); Electrochemical method — 1 method
- Personal dosimetry method — 1 method
- Potentiometric method — 1 method
Laboratory locations
- LABORATORIUM POMIARÓW ŚRODOWISKOWYCH — ul. Powstańców Śląskich 1
- Laboratorium Pomiarów Środowiskowych — ul. Opolska
Accreditation scope — test methods (33)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratorium Pomiarów Środowiskowych | |||||
| 1 | Workplace environment – air | Sampling for the assessment of occupational exposure to: dust agents – inhalable fraction – respirable fraction organic substances inorganic substances – respirable fraction |
Personal dosimetry method | PN-Z-04008-7:2002+Az1:2004 | |
| 2 | Workplace environment – air | Exposure index (calculated) | PN-Z-04008-7:2002+Az1:2004 | ||
| 3 | Workplace environment – air | Concentration of harmful dust agents - inhalable fraction: Coal (hard, brown) Range (0,03 – 20) mg/m3 |
Gravimetric method | PN-Z-04507:2022-05 | |
| 4 | Workplace environment – air | Concentration of harmful dust agents - respirable fraction: Coal (hard, brown) Range (0,04 – 7,3) mg/m3 |
Gravimetric method | PN-Z-04508:2022-05 | |
| 5 | Workplace environment – air | Stężenie ditlenku siarki, tlenku węgla SO2 (0,53 – 53) mg/m3 SO2 (0,2 – 20,0) ppm CO (4,68 – 117) mg/m3 CO (4 – 100) ppm |
Electrochemical method | PB/03.7/L.001 wydanie 3 z dnia 19.04.2023 r. | |
| 6 | Workplace environment – air | Concentration/content of crystalline silica (quartz, cristobalite) – respirable fraction Range (0,015 – 0,5) mg/m3 Range (10 – 400) μg w próbce |
Fourier transform infrared spectrometry (FT- IR) | Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130 | |
| 7 | Workplace environment – air | Benzene concentration Range (0,05 – 40) mg/m3 Range (0,016 – 12,52) ppm |
Gas chromatography with flame ionization detection (GC-FID) | PN-Z-04016-10:2005 | |
| 8 | Workplace environment – noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (25 – 138) dB C-weighted peak sound pressure level Range (38 – 138) dB |
Direct measurement method | PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 i Strategię 3 - punkt 11 | |
| 9 | Workplace environment – noise | Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) |
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 i Strategię 3 - punkt 11 | ||
| 10 | Workplace environment – hot microclimate | Air temperature Range (15 – 50) °C Natural wet bulb temperature Range (15 – 50) °C Black globe temperature Range (15 – 80) °C Air velocity Range (0,15 – 4,9) m/s |
Direct measurement method | PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04 | |
| 11 | Workplace environment – hot microclimate | WBGT index, WBGTeff index (calculated) | PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04 | ||
| 12 | Workplace environment – cold microclimate | Air temperature Range (-25 – 10) °C Black globe temperature Range (-25 – 10) °C Air humidity Range (10 – 90) % Air velocity Range (0,4 – 4,9) m/s |
Direct measurement method | PN-EN ISO 11079:2008 | |
| 13 | Workplace environment – cold microclimate | IREQmin index, IREQneutral index, twc index (calculated) | PN-EN ISO 11079:2008 | ||
| 14 | Waste gases | Stężenie tlenku węgla, ditlenku węgla, ditlenku siarki, tlenku azotu, tlenu CO (3,0 – 3000) mg/m3 CO2 (0,2 - 20) % SO2 (6,0 – 2000) mg/m3 NO (3,0 – 1000) mg/m3 O2 (3 - 15) % Regulated area: Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Non-dispersive infrared spectrometry (NDIR); Electrochemical method | PN-ISO 10396:2001 | |
| 15 | Wastewater | Sampling for chemical and physical testing | Manual method | PN-ISO 5667-10:2021-11 | |
| 16 | Wastewater | Temperature of wastewater/ collected wastewater sample Range (0,0 – 50) 0C |
PN-77/C-04584 | ||
| 17 | Water, wastewater | Total suspended solids (TSS) Range (5,0 – 500) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 18 | Water, wastewater | pH Range (4,0 – 12,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 19 | Water, wastewater | Stężenie cyjanków wolnych, związanych Range (0,005 – 20,0) mg/l |
Spectrophotometric method | PN-80/C-04603/01 | |
| 20 | Water, wastewater | Ammonium nitrogen concentration Range (0,40 – 800) mg/l |
Titrimetric method | PN-ISO 5664: 2002 | |
| 21 | Water, wastewater | Chloride concentration Range (5,0 – 4000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 22 | Water, wastewater | Chemiczne zapotrzebowanie tlenu - CHZT - Cr Range (10,0 –10000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 23 | Water, wastewater | Sulfate concentration Range (10 – 1000) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 24 | Water, wastewater | Biochemical oxygen demand BOD5 Range (0,50 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 25 | Water, wastewater | Biochemical oxygen demand BOD5 Range (3 – 2000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 26 | Water, wastewater | Sulfide concentration Range (0,008 – 20,0) mg/l |
Spectrophotometric method | PB/03.7/L.008 wydanie 1 z dnia 03.02.2020 r. | |
| 27 | Water, wastewater | Kjeldahl nitrogen concentration Range (1,0 – 1000) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 28 | Water, wastewater | Nitrate nitrogen concentration Range (0,20 – 100) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 29 | Water, wastewater | Nitrite nitrogen concentration Range (0,020 – 2,5) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 30 | Water, wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 31 | Water, wastewater | Stężenie węglowodorów aromatycznych (BTX): benzene (2,0 – 1000) μg/l toluene (2,0 – 1000) μg/l o-xylene (2,0 – 1000) μg/l suma (p-ksylen + m-ksylen) Range (4,0 – 2000) μg/l |
Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i z detekcją płomieniowo-jonizacyjną (HS-GC–FID) | PN-ISO 11423-1:2002 | |
| 32 | Water, wastewater | Sum of aromatic hydrocarbons (BTX) (calculated) | PN-ISO 11423-1:2002 | ||
| 33 | Workplace environment - air samples | Benzene content Range (0,0005 – 0,8) mg w próbce |
Gas chromatography with flame ionization detection (GC–FID) | PN-Z-04016-10:2005 | |
Reference standards (29)
PB/03.7/L.001 wydanie 3 z dnia 19.04.2023 r.
PB/03.7/L.008 wydanie 1 z dnia 03.02.2020 r.
PN-73/C-04576/14
PN-77/C-04584
PN-80/C-04603/01
PN-82/C-04576/08
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11079:2008
PN-EN ISO 5815-1:2019-12
PN-EN ISO 7243:2018-01
PN-EN ISO 7243:2018-01/Ap2:2020-04
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 i Strategię 3 - punkt 11
PN-ISO 10396:2001
PN-ISO 11423-1:2002
PN-ISO 15705:2005
PN-ISO 5664: 2002
PN-ISO 5667-10:2021-11
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-N-01307:1994
PN-Z-04008-7:2002+Az1:2004
PN-Z-04016-10:2005
PN-Z-04507:2022-05
PN-Z-04508:2022-05
Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130