PCA AB 1069 • Zdzieszowice, Poland • 33 methods

Water & wastewaterEnvironment

ARCELORMITTAL POLAND S.A. ODDZIAŁ W ZDZIESZOWICACH is a laboratory accredited by PCA under number AB 1069 (Zdzieszowice, Poland). Its accreditation scope covers 33 test methods in the following areas: Water & wastewater, Environment. Test objects include: Water, wastewater, Workplace environment – air, Wastewater, Workplace environment – cold microclimate. Most frequently used techniques: Spectrophotometric method, Gravimetric method, Direct measurement method.

At a glance

  • Accreditation number: PCA AB 1069
  • Methods in scope: 33
  • Types of test objects: 8
  • Techniques used: 13
  • City: Zdzieszowice, Poland
Accreditation number
AB 1069
Accreditation body
PCA
Address
LABORATORIUM POMIARÓW ŚRODOWISKOWYCH, ul. Powstańców Śląskich 1, 47-330 Zdzieszowice
City
Zdzieszowice, Poland

What this laboratory tests (8)

Analytical techniques used (13)

Laboratory locations

Accreditation scope — test methods (33)

No. Test object Methodology / Parameters Technique Reference document
Laboratorium Pomiarów Środowiskowych
1 Workplace environment – air Sampling for the assessment of occupational exposure to:
dust agents – inhalable fraction – respirable fraction organic substances inorganic substances – respirable fraction
Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
2 Workplace environment – air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004
3 Workplace environment – air Concentration of harmful dust agents - inhalable fraction:
Coal (hard, brown) Range (0,03 – 20) mg/m3
Gravimetric method PN-Z-04507:2022-05
4 Workplace environment – air Concentration of harmful dust agents - respirable fraction:
Coal (hard, brown) Range (0,04 – 7,3) mg/m3
Gravimetric method PN-Z-04508:2022-05
5 Workplace environment – air Stężenie ditlenku siarki, tlenku węgla
SO2 (0,53 – 53) mg/m3 SO2 (0,2 – 20,0) ppm CO (4,68 – 117) mg/m3 CO (4 – 100) ppm
Electrochemical method PB/03.7/L.001 wydanie 3 z dnia 19.04.2023 r.
6 Workplace environment – air Concentration/content of crystalline silica (quartz, cristobalite) – respirable fraction
Range (0,015 – 0,5) mg/m3 Range (10 – 400) μg w próbce
Fourier transform infrared spectrometry (FT- IR) Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130
7 Workplace environment – air Benzene concentration
Range (0,05 – 40) mg/m3 Range (0,016 – 12,52) ppm
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04016-10:2005
8 Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (25 – 138) dB C-weighted peak sound pressure level Range (38 – 138) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 i Strategię 3 - punkt 11
9 Workplace environment – noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 i Strategię 3 - punkt 11
10 Workplace environment – hot microclimate Air temperature
Range (15 – 50) °C Natural wet bulb temperature Range (15 – 50) °C Black globe temperature Range (15 – 80) °C Air velocity Range (0,15 – 4,9) m/s
Direct measurement method PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04
11 Workplace environment – hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01 | PN-EN ISO 7243:2018-01/Ap2:2020-04
12 Workplace environment – cold microclimate Air temperature
Range (-25 – 10) °C Black globe temperature Range (-25 – 10) °C Air humidity Range (10 – 90) % Air velocity Range (0,4 – 4,9) m/s
Direct measurement method PN-EN ISO 11079:2008
13 Workplace environment – cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008
14 Waste gases Stężenie tlenku węgla, ditlenku węgla, ditlenku siarki, tlenku azotu, tlenu
CO (3,0 – 3000) mg/m3 CO2 (0,2 - 20) % SO2 (6,0 – 2000) mg/m3 NO (3,0 – 1000) mg/m3 O2 (3 - 15) %
Regulated area: Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego prawnie The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Non-dispersive infrared spectrometry (NDIR); Electrochemical method PN-ISO 10396:2001
15 Wastewater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11
16 Wastewater Temperature of wastewater/ collected wastewater sample
Range (0,0 – 50) 0C
PN-77/C-04584
17 Water, wastewater Total suspended solids (TSS)
Range (5,0 – 500) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
18 Water, wastewater pH
Range (4,0 – 12,0)
Potentiometric method PN-EN ISO 10523:2012
19 Water, wastewater Stężenie cyjanków wolnych, związanych
Range (0,005 – 20,0) mg/l
Spectrophotometric method PN-80/C-04603/01
20 Water, wastewater Ammonium nitrogen concentration
Range (0,40 – 800) mg/l
Titrimetric method PN-ISO 5664: 2002
21 Water, wastewater Chloride concentration
Range (5,0 – 4000) mg/l
Titrimetric method PN-ISO 9297:1994
22 Water, wastewater Chemiczne zapotrzebowanie tlenu - CHZT - Cr
Range (10,0 –10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
23 Water, wastewater Sulfate concentration
Range (10 – 1000) mg/l
Gravimetric method PN-ISO 9280:2002
24 Water, wastewater Biochemical oxygen demand
BOD5 Range (0,50 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
25 Water, wastewater Biochemical oxygen demand
BOD5 Range (3 – 2000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
26 Water, wastewater Sulfide concentration
Range (0,008 – 20,0) mg/l
Spectrophotometric method PB/03.7/L.008 wydanie 1 z dnia 03.02.2020 r.
27 Water, wastewater Kjeldahl nitrogen concentration
Range (1,0 – 1000) mg/l
Titrimetric method PN-EN 25663:2001
28 Water, wastewater Nitrate nitrogen concentration
Range (0,20 – 100) mg/l
Spectrophotometric method PN-82/C-04576/08
29 Water, wastewater Nitrite nitrogen concentration
Range (0,020 – 2,5) mg/l
Spectrophotometric method PN-EN 26777:1999
30 Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14
31 Water, wastewater Stężenie węglowodorów aromatycznych (BTX):
benzene (2,0 – 1000) μg/l toluene (2,0 – 1000) μg/l o-xylene (2,0 – 1000) μg/l suma (p-ksylen + m-ksylen) Range (4,0 – 2000) μg/l
Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i z detekcją płomieniowo-jonizacyjną (HS-GC–FID) PN-ISO 11423-1:2002
32 Water, wastewater Sum of aromatic hydrocarbons (BTX) (calculated) PN-ISO 11423-1:2002
33 Workplace environment - air samples Benzene content
Range (0,0005 – 0,8) mg w próbce
Gas chromatography with flame ionization detection (GC–FID) PN-Z-04016-10:2005

Reference standards (29)

PB/03.7/L.001 wydanie 3 z dnia 19.04.2023 r.
PB/03.7/L.008 wydanie 1 z dnia 03.02.2020 r.
PN-73/C-04576/14
PN-77/C-04584
PN-80/C-04603/01
PN-82/C-04576/08
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11079:2008
PN-EN ISO 5815-1:2019-12
PN-EN ISO 7243:2018-01
PN-EN ISO 7243:2018-01/Ap2:2020-04
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej Strategię 2 - punkt 10 i Strategię 3 - punkt 11
PN-ISO 10396:2001
PN-ISO 11423-1:2002
PN-ISO 15705:2005
PN-ISO 5664: 2002
PN-ISO 5667-10:2021-11
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-N-01307:1994
PN-Z-04008-7:2002+Az1:2004
PN-Z-04016-10:2005
PN-Z-04507:2022-05
PN-Z-04508:2022-05