🇵🇱 „WODOCIĄGI I KANALIZACJA – ZGIERZ” Sp. z o.o. PL
Water & wastewater
„WODOCIĄGI I KANALIZACJA – ZGIERZ” Sp. z o.o. is a laboratory accredited by PCA under number AB 1064 (Zgierz, Poland). Its accreditation scope covers 52 test methods in the following areas: Water & wastewater. Test objects include: Water, Water, wastewater, Wastewater, Sewage sludge. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Gravimetric method.
At a glance
- Accreditation number: PCA AB 1064
- Methods in scope: 52
- Types of test objects: 7
- Techniques used: 11
- City: Zgierz, Poland
- Accreditation number
- AB 1064
- Accreditation body
- PCA
- Address
- ul. Andrzeja Struga 45, 95-100 Zgierz, LABORATORIUM, ul. Łukasińskiego 26, 95-100 Zgierz
- City
- Zgierz, Poland
What this laboratory tests (7)
- Water — 20 methods
- Water, wastewater — 11 methods
- Wastewater — 10 methods
- Sewage sludge — 7 methods
- Water intended for human consumption — 2 methods
- Rainwater, snowmelt water — 1 method
- Wastewater, rainwater, snowmelt water, water — 1 method
Analytical techniques used (11)
- Spectrophotometric method — 20 methods
- Titrimetric method — 8 methods
- Gravimetric method — 5 methods
- Colorimetric method — 2 methods
- Optical method — 2 methods
- Potentiometric method — 2 methods
- Conductometric method — 1 method
- Manual method — 1 method
- Manual method; Automatic method — 1 method
- Nephelometric method — 1 method
- Volumetric method — 1 method
Laboratory locations
- Laboratorium —
Accreditation scope — test methods (52)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratory | |||||
| 1 | Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2 | ||
| 2 | Water intended for human consumption | Sampling for chemical and physical testing Temperature Range (0,5 – 50) °C |
PN-ISO 5667-5:2017-10 | PN-77/C-04584 | ||
| 3 | Rainwater, snowmelt water | Sampling for chemical and physical testing Temperature Range (0,5 – 50) °C |
Manual method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 4 | Water | Sampling for chemical and physical testing Temperature Range (0,5 – 50) °C |
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6; 9.3; 9.4 | PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2; 6.1.2; 6.2; 6.3 | PN-77/C-04584 | ||
| 5 | Water | Ammonium ion concentration Range (0,10 – 1,0) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 6 | Water | Nitrate concentration Range (0,10 – 20,0) mg/l Nitrate nitrogen concentration Range (0,02 – 4,50) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 7 | Water | Manganese concentration Range (0,006 – 0,70) mg/l |
Spectrophotometric method | PB-06 wydanie z 7.05.2013 r. | na podstawie metody HACH 8149 | |
| 8 | Water | Total content of calcium and magnesium (total hardness) Range (5,0 – 500) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 9 | Water | Calcium concentration Range (2,0 – 100) mg/l |
Titrimetric method | PN-ISO 6058:1999 | |
| 10 | Water | Magnesium concentration (calculated) | PB-03 wydanie z dnia 16.03.2012 r. | ||
| 11 | Water | Free chlorine concentration Range (0,05 – 2,0) mg/l |
Colorimetric method | PB-07 wydanie z 28.03.2014 r. | na podstawie metody HACH 8021 | |
| 12 | Water | Chlorine dioxide concentration Range (0,04 – 5,0) mg/l |
Colorimetric method | PB-08 wydanie z 28.03.2014 r | na podstawie metody HACH 10126 | |
| 13 | Water | Aluminium concentration Range (0,02– 0,50) mg/l |
Spectrophotometric method | PB-09 wydanie z 18.12.2019 r. | na podstawie testu kuwetowego Hach-Lange LCK 301 | |
| 14 | Water | Nitrite concentration Range (0,012 – 0,20) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 15 | Water | Colour Range (3,0 –70) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012+Ap1:2015-06 metoda C | |
| 16 | Water | Turbidity Range (0,10 – 100) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 17 | Water | Total nitrogen concentration Range (1,0 – 16,0) mg/l |
Spectrophotometric method | PB-04 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 138, 238, 338 | |
| 18 | Water | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 19 | Water | Kjeldahl nitrogen concentration Range (2,0 – 10,0) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 20 | Water | Nitrite nitrogen concentration Range (0,01 – 1,00) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 21 | Water | Chemical oxygen demand – SP-COD Range (10,0 – 1000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 22 | Water | Phenol index Range (0,004 – 0,10) mg/l |
Spectrophotometric method | PN-ISO 6439:1994 | |
| 23 | Water | Ammonium nitrogen concentration Range (2,0 – 10,0) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 24 | Wastewater | Sampling for chemical and physical testing Temperature Range (0,5 – 50) °C |
Manual method; Automatic method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 25 | Wastewater | Chemical oxygen demand – SP-COD Range (10,0 – 10000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 26 | Wastewater | Total nitrogen concentration Range (1,0 – 100,0) mg/l |
Spectrophotometric method | PB-04 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 138, 238, 338 | |
| 27 | Wastewater | Phenol index Range (0,004 – 16,0) mg/l |
Spectrophotometric method | PN-ISO 6439:1994 | |
| 28 | Wastewater | Ammonium nitrogen concentration Range (2,0 – 250) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 29 | Wastewater | Kjeldahl nitrogen concentration Range (2,0 – 250) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 30 | Wastewater | Nitrite nitrogen concentration Range (0,01 – 0,25) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 31 | Wastewater | Nitrate nitrogen concentration Range (0,10 – 30,0) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 32 | Wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 33 | Wastewater | Sulfide concentration Range (0,20 – 20,0) mg/l |
Spectrophotometric method | PB-10 wydanie z 01.02.2021 r. | na podstawie testu kuwetowego Hach- Lange LCK 653 | |
| 34 | Wastewater, rainwater, snowmelt water, water | Total suspended solids (TSS) Range (2,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 35 | Water, wastewater | Electrical conductivity Range (100 – 7000) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 36 | Water, wastewater | pH Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 37 | Water, wastewater | Chloride concentration Range (5,0 – 1000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 38 | Water, wastewater | Sulfate concentration Range (10,0 – 500) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 39 | Water, wastewater | Iron concentration Range (0,02 – 15) mg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 40 | Water, wastewater | Total alkalinity Range (0,4 – 20) mmol/l |
Titrimetric method | PN-EN ISO 9963-1:2001 + Ap1:2004 | |
| 41 | Water, wastewater | Total phosphorus concentration Range (0,05 – 1,5) mg/l |
Spectrophotometric method | PB-05 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 349 | |
| 42 | Water, wastewater | Total phosphorus concentration Range (0,010– 20,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010 | |
| 43 | Water, wastewater | Biochemical oxygen demand – BOD5 Range (3 – 6000) mg/l O2 |
Optical method | PN-EN ISO 5815-1:2019-12 | |
| 44 | Water, wastewater | Biochemical oxygen demand – BOD5 Range (0,5 – 6,0) mg/l O2 |
Optical method | PN-EN 1899-2:2002 z wyłączeniem punktu 7.2 I-19 wydanie z 31.03.2009 r. | |
| 45 | Water, wastewater | Ammonium nitrogen concentration Range (0,05 – 2,0) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 46 | Sewage sludge | Sampling for chemical and physical testing | P N - E N ISO 5667-13:2011 | ||
| 47 | Sewage sludge | Dry residue / water content Range (1,00 – 99,0) % |
Gravimetric method | PN-EN 15934:2013-02 metoda A | |
| 48 | Sewage sludge | Loss on ignition of dry matter (LOI)/ Residue on ignition Range (1,00 – 99,0) % |
Gravimetric method | PN-EN 15935:2022-01 | |
| 49 | Sewage sludge | pH – in H2O Range 2,0 – 13,0 |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 50 | Sewage sludge | Total suspended solids (TSS) Range (100 – 10000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 51 | Sewage sludge | Relative volume Range (10 – 1000) ml/l |
Volumetric method | PN-EN 14702-1:2008 | |
| 52 | Sewage sludge | Sludge volume index (calculated) | PN-EN 14702-1:2008 | ||
Reference standards (48)
P N - E N ISO 5667-13:2011
PB-03 wydanie z dnia 16.03.2012 r.
PB-04 wydanie z 7.05.2013 r.
PB-05 wydanie z 7.05.2013 r.
PB-06 wydanie z 7.05.2013 r.
PB-07 wydanie z 28.03.2014 r.
PB-08 wydanie z 28.03.2014 r
PB-09 wydanie z 18.12.2019 r.
PB-10 wydanie z 01.02.2021 r.
PN-73/C-04576/14
PN-77/C-04584
PN-82/C-04576/08
PN-EN 14702-1:2008
PN-EN 15934:2013-02 metoda A
PN-EN 15935:2022-01
PN-EN 1899-2:2002 z wyłączeniem punktu 7.2 I-19 wydanie z 31.03.2009 r.
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6; 9.3; 9.4
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012+Ap1:2015-06 metoda C
PN-EN ISO 9963-1:2001 + Ap1:2004
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2; 6.1.2; 6.2; 6.3
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 6439:1994
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
na podstawie metody HACH 10126
na podstawie metody HACH 8021
na podstawie metody HACH 8149
na podstawie testu kuwetowego Hach- Lange LCK 653
na podstawie testu kuwetowego Hach-Lange LCK 138, 238, 338
na podstawie testu kuwetowego Hach-Lange LCK 301
na podstawie testu kuwetowego Hach-Lange LCK 349