🇵🇱 „WODOCIĄGI I KANALIZACJA – ZGIERZ” Sp. z o.o. PL

PCA AB 1064 • Zgierz, Poland • 52 methods

Water & wastewater

„WODOCIĄGI I KANALIZACJA – ZGIERZ” Sp. z o.o. is a laboratory accredited by PCA under number AB 1064 (Zgierz, Poland). Its accreditation scope covers 52 test methods in the following areas: Water & wastewater. Test objects include: Water, Water, wastewater, Wastewater, Sewage sludge. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Gravimetric method.

At a glance

  • Accreditation number: PCA AB 1064
  • Methods in scope: 52
  • Types of test objects: 7
  • Techniques used: 11
  • City: Zgierz, Poland
Accreditation number
AB 1064
Accreditation body
PCA
Address
ul. Andrzeja Struga 45, 95-100 Zgierz, LABORATORIUM, ul. Łukasińskiego 26, 95-100 Zgierz
City
Zgierz, Poland

What this laboratory tests (7)

Analytical techniques used (11)

Laboratory locations

Accreditation scope — test methods (52)

No. Test object Methodology / Parameters Technique Reference document
Laboratory
1 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2
2 Water intended for human consumption Sampling for chemical and physical testing Temperature
Range (0,5 – 50) °C
PN-ISO 5667-5:2017-10 | PN-77/C-04584
3 Rainwater, snowmelt water Sampling for chemical and physical testing
Temperature Range (0,5 – 50) °C
Manual method PN-ISO 5667-10:2021-11 | PN-77/C-04584
4 Water Sampling for chemical and physical testing Temperature
Range (0,5 – 50) °C
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6; 9.3; 9.4 | PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2; 6.1.2; 6.2; 6.3 | PN-77/C-04584
5 Water Ammonium ion concentration
Range (0,10 – 1,0) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
6 Water Nitrate concentration
Range (0,10 – 20,0) mg/l Nitrate nitrogen concentration Range (0,02 – 4,50) mg/l
Spectrophotometric method PN-82/C-04576/08
7 Water Manganese concentration
Range (0,006 – 0,70) mg/l
Spectrophotometric method PB-06 wydanie z 7.05.2013 r. | na podstawie metody HACH 8149
8 Water Total content of calcium and magnesium (total hardness)
Range (5,0 – 500) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
9 Water Calcium concentration
Range (2,0 – 100) mg/l
Titrimetric method PN-ISO 6058:1999
10 Water Magnesium concentration (calculated) PB-03 wydanie z dnia 16.03.2012 r.
11 Water Free chlorine concentration
Range (0,05 – 2,0) mg/l
Colorimetric method PB-07 wydanie z 28.03.2014 r. | na podstawie metody HACH 8021
12 Water Chlorine dioxide concentration
Range (0,04 – 5,0) mg/l
Colorimetric method PB-08 wydanie z 28.03.2014 r | na podstawie metody HACH 10126
13 Water Aluminium concentration
Range (0,02– 0,50) mg/l
Spectrophotometric method PB-09 wydanie z 18.12.2019 r. | na podstawie testu kuwetowego Hach-Lange LCK 301
14 Water Nitrite concentration
Range (0,012 – 0,20) mg/l
Spectrophotometric method PN-EN 26777:1999
15 Water Colour
Range (3,0 –70) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012+Ap1:2015-06 metoda C
16 Water Turbidity
Range (0,10 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
17 Water Total nitrogen concentration
Range (1,0 – 16,0) mg/l
Spectrophotometric method PB-04 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 138, 238, 338
18 Water Total nitrogen concentration (calculated) PN-73/C-04576/14
19 Water Kjeldahl nitrogen concentration
Range (2,0 – 10,0) mg/l
Titrimetric method PN-EN 25663:2001
20 Water Nitrite nitrogen concentration
Range (0,01 – 1,00) mg/l
Spectrophotometric method PN-EN 26777:1999
21 Water Chemical oxygen demand – SP-COD
Range (10,0 – 1000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
22 Water Phenol index
Range (0,004 – 0,10) mg/l
Spectrophotometric method PN-ISO 6439:1994
23 Water Ammonium nitrogen concentration
Range (2,0 – 10,0) mg/l
Titrimetric method PN-ISO 5664:2002
24 Wastewater Sampling for chemical and physical testing
Temperature Range (0,5 – 50) °C
Manual method; Automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
25 Wastewater Chemical oxygen demand – SP-COD
Range (10,0 – 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
26 Wastewater Total nitrogen concentration
Range (1,0 – 100,0) mg/l
Spectrophotometric method PB-04 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 138, 238, 338
27 Wastewater Phenol index
Range (0,004 – 16,0) mg/l
Spectrophotometric method PN-ISO 6439:1994
28 Wastewater Ammonium nitrogen concentration
Range (2,0 – 250) mg/l
Titrimetric method PN-ISO 5664:2002
29 Wastewater Kjeldahl nitrogen concentration
Range (2,0 – 250) mg/l
Titrimetric method PN-EN 25663:2001
30 Wastewater Nitrite nitrogen concentration
Range (0,01 – 0,25) mg/l
Spectrophotometric method PN-EN 26777:1999
31 Wastewater Nitrate nitrogen concentration
Range (0,10 – 30,0) mg/l
Spectrophotometric method PN-82/C-04576/08
32 Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14
33 Wastewater Sulfide concentration
Range (0,20 – 20,0) mg/l
Spectrophotometric method PB-10 wydanie z 01.02.2021 r. | na podstawie testu kuwetowego Hach- Lange LCK 653
34 Wastewater, rainwater, snowmelt water, water Total suspended solids (TSS)
Range (2,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
35 Water, wastewater Electrical conductivity
Range (100 – 7000) μS/cm
Conductometric method PN-EN 27888:1999
36 Water, wastewater pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
37 Water, wastewater Chloride concentration
Range (5,0 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
38 Water, wastewater Sulfate concentration
Range (10,0 – 500) mg/l
Gravimetric method PN-ISO 9280:2002
39 Water, wastewater Iron concentration
Range (0,02 – 15) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
40 Water, wastewater Total alkalinity
Range (0,4 – 20) mmol/l
Titrimetric method PN-EN ISO 9963-1:2001 + Ap1:2004
41 Water, wastewater Total phosphorus concentration
Range (0,05 – 1,5) mg/l
Spectrophotometric method PB-05 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 349
42 Water, wastewater Total phosphorus concentration
Range (0,010– 20,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010
43 Water, wastewater Biochemical oxygen demand – BOD5
Range (3 – 6000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12
44 Water, wastewater Biochemical oxygen demand – BOD5
Range (0,5 – 6,0) mg/l O2
Optical method PN-EN 1899-2:2002 z wyłączeniem punktu 7.2 I-19 wydanie z 31.03.2009 r.
45 Water, wastewater Ammonium nitrogen concentration
Range (0,05 – 2,0) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
46 Sewage sludge Sampling for chemical and physical testing P N - E N ISO 5667-13:2011
47 Sewage sludge Dry residue / water content
Range (1,00 – 99,0) %
Gravimetric method PN-EN 15934:2013-02 metoda A
48 Sewage sludge Loss on ignition of dry matter (LOI)/ Residue on ignition
Range (1,00 – 99,0) %
Gravimetric method PN-EN 15935:2022-01
49 Sewage sludge pH – in H2O
Range 2,0 – 13,0
Potentiometric method PN-EN ISO 10390:2022-09
50 Sewage sludge Total suspended solids (TSS)
Range (100 – 10000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
51 Sewage sludge Relative volume
Range (10 – 1000) ml/l
Volumetric method PN-EN 14702-1:2008
52 Sewage sludge Sludge volume index (calculated) PN-EN 14702-1:2008

Reference standards (48)

P N - E N ISO 5667-13:2011
PB-03 wydanie z dnia 16.03.2012 r.
PB-04 wydanie z 7.05.2013 r.
PB-05 wydanie z 7.05.2013 r.
PB-06 wydanie z 7.05.2013 r.
PB-07 wydanie z 28.03.2014 r.
PB-08 wydanie z 28.03.2014 r
PB-09 wydanie z 18.12.2019 r.
PB-10 wydanie z 01.02.2021 r.
PN-73/C-04576/14
PN-77/C-04584
PN-82/C-04576/08
PN-EN 14702-1:2008
PN-EN 15934:2013-02 metoda A
PN-EN 15935:2022-01
PN-EN 1899-2:2002 z wyłączeniem punktu 7.2 I-19 wydanie z 31.03.2009 r.
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6; 9.3; 9.4
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012+Ap1:2015-06 metoda C
PN-EN ISO 9963-1:2001 + Ap1:2004
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2; 6.1.2; 6.2; 6.3
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 6439:1994
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
na podstawie metody HACH 10126
na podstawie metody HACH 8021
na podstawie metody HACH 8149
na podstawie testu kuwetowego Hach- Lange LCK 653
na podstawie testu kuwetowego Hach-Lange LCK 138, 238, 338
na podstawie testu kuwetowego Hach-Lange LCK 301
na podstawie testu kuwetowego Hach-Lange LCK 349