{"lab":{"_id":"69ad52a3de79e566650fb568","accr_number":"AB 1064","country":"PL","accr_body":"PCA","address":"ul. Andrzeja Struga 45, 95-100 Zgierz, LABORATORIUM, ul. Łukasińskiego 26, 95-100 Zgierz","categories":["water"],"city":"Zgierz","imported_at":"2026-03-08T10:42:43.265Z","methods_count":52,"name":"„WODOCIĄGI I KANALIZACJA – ZGIERZ” Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1064.pdf"],"scope_summary":"","search_text":"„wodociągi i kanalizacja – zgierz” sp. z o.o. ul. andrzeja struga 45, 95-100 zgierz, laboratorium, ul. łukasińskiego 26, 95-100 zgierz water other pharma electronics","status":"active","updated_at":"2026-03-08T14:50:14.744Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:56:39.574Z","parse_date":"2026-08-13T07:56:39.574Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://www.wodkan.zgierz.pl/laboratorium-akredytowane/","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"N/28/P; N/29/P; N/30/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów","en":"Tests of physical properties and sampling of water, drinking water, sewage, sediments"},{"codes":"P/29","pl":"Pobieranie próbek wody do spożycia przez ludzi","en":"Sampling of drinking water"}],"issue":{"no":"20","date":"15.05.2026"},"map_coord":[51.847548,19.389226],"map_geo":"nominatim-street","lab_locations":[{"name":"Laboratorium","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/c5765fcce9f2a0abca6bc15562e1fd0c/AB%201064.pdf","has_en":true,"category_counts":{"water":52,"microbiology":1},"category_scores":{"water":51.02,"microbiology":0.02},"has_zh":true,"lab_locations_zh":[{"name":"实验室","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d78b70636ba417e41a157","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt. 4.4.2","categories":["water","microbiology"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing Laboratory PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 实验室 PN-EN ISO 19458:2007 z wyłączeniem pkt. 4.4.2","test_object_zh":"生活饮用水"},{"_id":"6a7d78b70636ba417e41a158","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","parameters":[{"name":"Zakres","range":"(0,5 – 50) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,5 – 50) °C","reference":"PN-ISO 5667-5:2017-10 | PN-77/C-04584","norm_bases":["PN-ISO 5667-5:2017-10","PN-77/C-04584"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,5 – 50) °C PN-ISO 5667-5:2017-10 | PN-77/C-04584 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (0,5 – 50) °C PN-ISO 5667-5:2017-10 | PN-77/C-04584","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing Temperature","parameters_en":[{"name":"Range","range":"(0,5 – 50) °C"}],"search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature Laboratory Range PN-ISO 5667-5:2017-10 | PN-77/C-04584","test_object_en":"Water intended for human consumption","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,5 – 50) °C"}],"search_zh":"生活饮用水 化学和物理检测采样 温度 实验室 范围 PN-ISO 5667-5:2017-10 | PN-77/C-04584","test_object_zh":"生活饮用水","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a7d78b70636ba417e41a159","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(0,5 – 50) °C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,5 – 50) °C\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe, wody roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,5 – 50) °C\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Wody opadowe, wody roztopowe Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,5 – 50) °C\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(0,5 – 50) °C"}],"search_en":"Rainwater, snowmelt water Sampling for chemical and physical testing Manual method Laboratory Temperature Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method","test_object_en":"Rainwater, snowmelt water","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(0,5 – 50) °C"}],"search_zh":"雨水、融雪水 化学与物理检测用样品采集 手工法 实验室 温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"雨水、融雪水","technique_zh":"手工法"},{"_id":"6a7d78b70636ba417e41a15a","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","parameters":[{"name":"Zakres","range":"(0,5 – 50) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,5 – 50) °C","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6; 9.3; 9.4 | PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2; 6.1.2; 6.2; 6.3 | PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6; 9.3; 9.4","PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2; 6.1.2; 6.2; 6.3","PN-77/C-04584"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,5 – 50) °C PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6; 9.3; 9.4 | PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2; 6.1.2; 6.2; 6.3 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (0,5 – 50) °C PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.2; 7.3; 7.5; 7.6; 9.3; 9.4 | PN-ISO 5667-11:2017-10 z wylaczeniem pkt. 5.2; 6.1.2; 6.2; 6.3 | PN-77/C-04584","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing Temperature","parameters_en":[{"name":"Range","range":"(0,5 – 50) °C"}],"search_en":"Water Sampling for chemical and physical testing Temperature Laboratory Range PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6; 9.3; 9.4 | PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2; 6.1.2; 6.2; 6.3 | PN-77/C-04584","test_object_en":"Water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,5 – 50) °C"}],"search_zh":"水 化学和物理检测采样 温度 实验室 范围 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6; 9.3; 9.4 | PN-ISO 5667-11:2017-10 z wyłączeniem pkt. 5.2; 6.1.2; 6.2; 6.3 | PN-77/C-04584","test_object_zh":"水","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a7d78b70636ba417e41a15b","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,10 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,10 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie jonu amonowego\nZakres (0,10 – 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda Stezenie jonu amonowego\nZakres (0,10 – 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,10 – 1,0) mg/l"}],"search_en":"Water Ammonium ion concentration Spectrophotometric method Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 1,0) mg/l"}],"search_zh":"水 铵离子浓度 分光光度法 实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a7d78b70636ba417e41a15c","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,10 – 20,0) mg/l"},{"name":"Stężenie azotu azotanowego"},{"name":"Zakres","range":"(0,02 – 4,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres:\nZakres (0,10 – 20,0) mg/l\nStężenie azotu azotanowego\nZakres (0,02 – 4,50) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotanów\nZakres:\nZakres (0,10 – 20,0) mg/l\nStężenie azotu azotanowego\nZakres (0,02 – 4,50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda Stezenie azotanow\nZakres:\nZakres (0,10 – 20,0) mg/l\nStezenie azotu azotanowego\nZakres (0,02 – 4,50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,10 – 20,0) mg/l"},{"name":"Nitrate nitrogen concentration"},{"name":"Range","range":"(0,02 – 4,50) mg/l"}],"search_en":"Water Nitrate concentration Spectrophotometric method Laboratory Range Nitrate nitrogen concentration Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 20,0) mg/l"},{"name":"硝态氮浓度"},{"name":"范围","range":"(0,02 – 4,50) mg/l"}],"search_zh":"水 硝酸盐浓度 分光光度法 实验室 范围 硝态氮浓度 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a7d78b70636ba417e41a15d","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,006 – 0,70) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,006 – 0,70) mg/l\nMetoda spektrofotometryczna","reference":"PB-06 wydanie z 7.05.2013 r. | na podstawie metody HACH 8149","norm_bases":["PB-06 wydanie z 7.05.2013 r.","na podstawie metody HACH 8149"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie manganu\nZakres (0,006 – 0,70) mg/l\nMetoda spektrofotometryczna PB-06 wydanie z 7.05.2013 r. | na podstawie metody HACH 8149 Woda Stezenie manganu\nZakres (0,006 – 0,70) mg/l\nMetoda spektrofotometryczna PB-06 wydanie z 7.05.2013 r. | na podstawie metody HACH 8149","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,006 – 0,70) mg/l"}],"search_en":"Water Manganese concentration Spectrophotometric method Laboratory Range PB-06 wydanie z 7.05.2013 r. | na podstawie metody HACH 8149","technique_en":"Spectrophotometric method","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,006 – 0,70) mg/l"}],"search_zh":"水 锰浓度 分光光度法 实验室 范围 PB-06 wydanie z 7.05.2013 r. | na podstawie metody HACH 8149","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a7d78b70636ba417e41a15e","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(5,0 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5,0 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5,0 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (5,0 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(5,0 – 500) mg/l CaCO3"}],"search_en":"Water Total content of calcium and magnesium (total hardness) Titrimetric method Laboratory Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(5,0 – 500) mg/l CaCO3"}],"search_zh":"水 钙与镁总量（总硬度） 滴定法 实验室 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a7d78b70636ba417e41a15f","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(2,0 – 100) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres (2,0 – 100) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie wapnia\nZakres (2,0 – 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda Stezenie wapnia\nZakres (2,0 – 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(2,0 – 100) mg/l"}],"search_en":"Water Calcium concentration Titrimetric method Laboratory Range PN-ISO 6058:1999","technique_en":"Titrimetric method","test_object_en":"Water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(2,0 – 100) mg/l"}],"search_zh":"水 钙浓度 滴定法 实验室 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"钙浓度"},{"_id":"6a7d78b70636ba417e41a160","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie magnezu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PB-03 wydanie z dnia 16.03.2012 r.","norm_bases":["PB-03 wydanie z dnia 16.03.2012 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie magnezu (z obliczeń) PB-03 wydanie z dnia 16.03.2012 r. Woda Stezenie magnezu (z obliczen) PB-03 wydanie z dnia 16.03.2012 r.","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Magnesium concentration (calculated)","search_en":"Water Magnesium concentration (calculated) Laboratory PB-03 wydanie z dnia 16.03.2012 r.","test_object_en":"Water","lab_section_zh":"实验室","search_zh":"水 镁浓度（计算值） 实验室 PB-03 wydanie z dnia 16.03.2012 r.","test_object_zh":"水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a7d78b70636ba417e41a161","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda kolorymetryczna","reference":"PB-07 wydanie z 28.03.2014 r. | na podstawie metody HACH 8021","norm_bases":["PB-07 wydanie z 28.03.2014 r.","na podstawie metody HACH 8021"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda kolorymetryczna PB-07 wydanie z 28.03.2014 r. | na podstawie metody HACH 8021 Woda Stezenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda kolorymetryczna PB-07 wydanie z 28.03.2014 r. | na podstawie metody HACH 8021","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/l"}],"search_en":"Water Free chlorine concentration Colorimetric method Laboratory Range PB-07 wydanie z 28.03.2014 r. | na podstawie metody HACH 8021","technique_en":"Colorimetric method","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/l"}],"search_zh":"水 游离氯浓度 比色法 实验室 范围 PB-07 wydanie z 28.03.2014 r. | na podstawie metody HACH 8021","technique_zh":"比色法","test_object_zh":"水"},{"_id":"6a7d78b70636ba417e41a162","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie dwutlenku chloru","parameters":[{"name":"Zakres","range":"(0,04 – 5,0) mg/l"}],"technique":"Metoda kolorymetryczna","techniques":["Metoda kolorymetryczna"],"computed":[],"activity":"Stężenie dwutlenku chloru\nZakres (0,04 – 5,0) mg/l\nMetoda kolorymetryczna","reference":"PB-08 wydanie z 28.03.2014 r | na podstawie metody HACH 10126","norm_bases":["PB-08 wydanie z 28.03.2014 r","na podstawie metody HACH 10126"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie dwutlenku chloru\nZakres (0,04 – 5,0) mg/l\nMetoda kolorymetryczna PB-08 wydanie z 28.03.2014 r | na podstawie metody HACH 10126 Woda Stezenie dwutlenku chloru\nZakres (0,04 – 5,0) mg/l\nMetoda kolorymetryczna PB-08 wydanie z 28.03.2014 r | na podstawie metody HACH 10126","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chlorine dioxide concentration","parameters_en":[{"name":"Range","range":"(0,04 – 5,0) mg/l"}],"search_en":"Water Chlorine dioxide concentration Colorimetric method Laboratory Range PB-08 wydanie z 28.03.2014 r | na podstawie metody HACH 10126","technique_en":"Colorimetric method","test_object_en":"Water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,04 – 5,0) mg/l"}],"search_zh":"水 比色法 实验室 范围 PB-08 wydanie z 28.03.2014 r | na podstawie metody HACH 10126","technique_zh":"比色法","test_object_zh":"水"},{"_id":"6a7d78b70636ba417e41a163","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie glinu","parameters":[{"name":"Zakres","range":"(0,02– 0,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie glinu\nZakres (0,02– 0,50) mg/l\nMetoda spektrofotometryczna","reference":"PB-09 wydanie z 18.12.2019 r. | na podstawie testu kuwetowego Hach-Lange LCK 301","norm_bases":["PB-09 wydanie z 18.12.2019 r.","na podstawie testu kuwetowego Hach-Lange LCK 301"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie glinu\nZakres (0,02– 0,50) mg/l\nMetoda spektrofotometryczna PB-09 wydanie z 18.12.2019 r. | na podstawie testu kuwetowego Hach-Lange LCK 301 Woda Stezenie glinu\nZakres (0,02– 0,50) mg/l\nMetoda spektrofotometryczna PB-09 wydanie z 18.12.2019 r. | na podstawie testu kuwetowego Hach-Lange LCK 301","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Aluminium concentration","parameters_en":[{"name":"Range","range":"(0,02– 0,50) mg/l"}],"search_en":"Water Aluminium concentration Spectrophotometric method Laboratory Range PB-09 wydanie z 18.12.2019 r. | na podstawie testu kuwetowego Hach-Lange LCK 301","technique_en":"Spectrophotometric method","test_object_en":"Water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,02– 0,50) mg/l"}],"search_zh":"水 铝浓度 分光光度法 实验室 范围 PB-09 wydanie z 18.12.2019 r. | na podstawie testu kuwetowego Hach-Lange LCK 301","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"铝浓度"},{"_id":"6a7d78b70636ba417e41a164","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,012 – 0,20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,012 – 0,20) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotynów\nZakres (0,012 – 0,20) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda Stezenie azotynow\nZakres (0,012 – 0,20) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,012 – 0,20) mg/l"}],"search_en":"Water Nitrite concentration Spectrophotometric method Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,012 – 0,20) mg/l"}],"search_zh":"水 亚硝酸盐浓度 分光光度法 实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a7d78b70636ba417e41a165","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(3,0 –70) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (3,0 –70) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 metoda C","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 metoda C"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Barwa\nZakres (3,0 –70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 metoda C Woda Barwa\nZakres (3,0 –70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015-06 metoda C","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(3,0 –70) mg/l Pt"}],"search_en":"Water Colour Spectrophotometric method Laboratory Range PN-EN ISO 7887:2012+Ap1:2015-06 metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(3,0 –70) mg/l Pt"}],"search_zh":"水 色度 分光光度法 实验室 范围 PN-EN ISO 7887:2012+Ap1:2015-06 metoda C","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a7d78b70636ba417e41a166","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Metnosc\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 – 100) NTU"}],"search_en":"Water Turbidity Nephelometric method Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 100) NTU"}],"search_zh":"水 浊度 浊度法（散射法） 实验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水"},{"_id":"6a7d78b70636ba417e41a167","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(1,0 – 16,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (1,0 – 16,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-04 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 138, 238, 338","norm_bases":["PB-04 wydanie z 7.05.2013 r.","na podstawie testu kuwetowego Hach-Lange LCK 138, 238, 338"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu ogólnego\nZakres (1,0 – 16,0) mg/l\nMetoda spektrofotometryczna PB-04 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 138, 238, 338 Woda Stezenie azotu ogolnego\nZakres (1,0 – 16,0) mg/l\nMetoda spektrofotometryczna PB-04 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 138, 238, 338","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 16,0) mg/l"}],"search_en":"Water Total nitrogen concentration Spectrophotometric method Laboratory Range PB-04 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 138, 238, 338","technique_en":"Spectrophotometric method","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 16,0) mg/l"}],"search_zh":"水 总氮浓度 分光光度法 实验室 范围 PB-04 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 138, 238, 338","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a7d78b70636ba417e41a168","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Woda Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water Total nitrogen concentration (calculated) Laboratory PN-73/C-04576/14","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"总氮浓度（计算值）","search_zh":"水 总氮浓度（计算值） 实验室 PN-73/C-04576/14","test_object_zh":"水"},{"_id":"6a7d78b70636ba417e41a169","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(2,0 – 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (2,0 – 10,0) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu Kjeldahla\nZakres (2,0 – 10,0) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda Stezenie azotu Kjeldahla\nZakres (2,0 – 10,0) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,0 – 10,0) mg/l"}],"search_en":"Water Kjeldahl nitrogen concentration Titrimetric method Laboratory Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 10,0) mg/l"}],"search_zh":"水 凯氏氮浓度 滴定法 实验室 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a7d78b70636ba417e41a16a","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,01 – 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,01 – 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu azotynowego\nZakres (0,01 – 1,00) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda Stezenie azotu azotynowego\nZakres (0,01 – 1,00) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,01 – 1,00) mg/l"}],"search_en":"Water Nitrite nitrogen concentration Spectrophotometric method Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 1,00) mg/l"}],"search_zh":"水 亚硝态氮浓度 分光光度法 实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a7d78b70636ba417e41a16b","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Chemiczne zapotrzebowanie tlenu – SP-ChZT","parameters":[{"name":"Zakres","range":"(10,0 – 1000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – SP-ChZT\nZakres (10,0 – 1000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Chemiczne zapotrzebowanie tlenu – SP-ChZT\nZakres (10,0 – 1000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda Chemiczne zapotrzebowanie tlenu – SP-ChZT\nZakres (10,0 – 1000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chemical oxygen demand – SP-COD","parameters_en":[{"name":"Range","range":"(10,0 – 1000) mg/l O2"}],"search_en":"Water Chemical oxygen demand – SP-COD Spectrophotometric method Laboratory Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(10,0 – 1000) mg/l O2"}],"search_zh":"水 分光光度法 实验室 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a7d78b70636ba417e41a16c","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,004 – 0,10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,004 – 0,10) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Indeks fenolowy\nZakres (0,004 – 0,10) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 Woda Indeks fenolowy\nZakres (0,004 – 0,10) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,004 – 0,10) mg/l"}],"search_en":"Water Phenol index Spectrophotometric method Laboratory Range PN-ISO 6439:1994","technique_en":"Spectrophotometric method","test_object_en":"Water","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,004 – 0,10) mg/l"}],"search_zh":"水 酚指数 分光光度法 实验室 范围 PN-ISO 6439:1994","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"酚指数"},{"_id":"6a7d78b70636ba417e41a16d","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(2,0 – 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (2,0 – 10,0) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu amonowego\nZakres (2,0 – 10,0) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda Stezenie azotu amonowego\nZakres (2,0 – 10,0) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,0 – 10,0) mg/l"}],"search_en":"Water Ammonium nitrogen concentration Titrimetric method Laboratory Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water","lab_section_zh":"实验室","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 10,0) mg/l"}],"search_zh":"水 氨氮浓度 滴定法 实验室 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a7d78b70636ba417e41a16e","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(0,5 – 50) °C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,5 – 50) °C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,5 – 50) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,5 – 50) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(0,5 – 50) °C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Laboratory Temperature Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(0,5 – 50) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 实验室 温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a7d78b70636ba417e41a16f","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu – SP-ChZT","parameters":[{"name":"Zakres","range":"(10,0 – 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu – SP-ChZT\nZakres (10,0 – 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu – SP-ChZT\nZakres (10,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu – SP-ChZT\nZakres (10,0 – 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chemical oxygen demand – SP-COD","parameters_en":[{"name":"Range","range":"(10,0 – 10000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand – SP-COD Spectrophotometric method Laboratory Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(10,0 – 10000) mg/l O2"}],"search_zh":"污水 分光光度法 实验室 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d78b70636ba417e41a170","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(1,0 – 100,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (1,0 – 100,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-04 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 138, 238, 338","norm_bases":["PB-04 wydanie z 7.05.2013 r.","na podstawie testu kuwetowego Hach-Lange LCK 138, 238, 338"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego\nZakres (1,0 – 100,0) mg/l\nMetoda spektrofotometryczna PB-04 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 138, 238, 338 Scieki Stezenie azotu ogolnego\nZakres (1,0 – 100,0) mg/l\nMetoda spektrofotometryczna PB-04 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 138, 238, 338","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 100,0) mg/l"}],"search_en":"Wastewater Total nitrogen concentration Spectrophotometric method Laboratory Range PB-04 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 138, 238, 338","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 100,0) mg/l"}],"search_zh":"污水 总氮浓度 分光光度法 实验室 范围 PB-04 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 138, 238, 338","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d78b70636ba417e41a171","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,004 – 16,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,004 – 16,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Indeks fenolowy\nZakres (0,004 – 16,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 Scieki Indeks fenolowy\nZakres (0,004 – 16,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,004 – 16,0) mg/l"}],"search_en":"Wastewater Phenol index Spectrophotometric method Laboratory Range PN-ISO 6439:1994","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,004 – 16,0) mg/l"}],"search_zh":"污水 酚指数 分光光度法 实验室 范围 PN-ISO 6439:1994","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"酚指数"},{"_id":"6a7d78b70636ba417e41a172","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(2,0 – 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (2,0 – 250) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (2,0 – 250) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres (2,0 – 250) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,0 – 250) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Laboratory Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 250) mg/l"}],"search_zh":"污水 氨氮浓度 滴定法 实验室 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a7d78b70636ba417e41a173","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(2,0 – 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (2,0 – 250) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (2,0 – 250) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (2,0 – 250) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,0 – 250) mg/l"}],"search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Laboratory Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 250) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 实验室 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a7d78b70636ba417e41a174","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,01 – 0,25) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,01 – 0,25) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres (0,01 – 0,25) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego\nZakres (0,01 – 0,25) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,01 – 0,25) mg/l"}],"search_en":"Wastewater Nitrite nitrogen concentration Spectrophotometric method Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 0,25) mg/l"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d78b70636ba417e41a175","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,10 – 30,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,10 – 30,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,10 – 30,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Scieki Stezenie azotu azotanowego\nZakres (0,10 – 30,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 – 30,0) mg/l"}],"search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Laboratory Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 30,0) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 实验室 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7d78b70636ba417e41a176","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Wastewater Total nitrogen concentration (calculated) Laboratory PN-73/C-04576/14","test_object_en":"Wastewater","lab_section_zh":"实验室","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） 实验室 PN-73/C-04576/14","test_object_zh":"污水"},{"_id":"6a7d78b70636ba417e41a177","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie siarczków","parameters":[{"name":"Zakres","range":"(0,20 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczków\nZakres (0,20 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-10 wydanie z 01.02.2021 r. | na podstawie testu kuwetowego Hach- Lange LCK 653","norm_bases":["PB-10 wydanie z 01.02.2021 r.","na podstawie testu kuwetowego Hach- Lange LCK 653"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie siarczków\nZakres (0,20 – 20,0) mg/l\nMetoda spektrofotometryczna PB-10 wydanie z 01.02.2021 r. | na podstawie testu kuwetowego Hach- Lange LCK 653 Scieki Stezenie siarczkow\nZakres (0,20 – 20,0) mg/l\nMetoda spektrofotometryczna PB-10 wydanie z 01.02.2021 r. | na podstawie testu kuwetowego Hach- Lange LCK 653","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sulfide concentration","parameters_en":[{"name":"Range","range":"(0,20 – 20,0) mg/l"}],"search_en":"Wastewater Sulfide concentration Spectrophotometric method Laboratory Range PB-10 wydanie z 01.02.2021 r. | na podstawie testu kuwetowego Hach- Lange LCK 653","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,20 – 20,0) mg/l"}],"search_zh":"污水 硫化物浓度 分光光度法 实验室 范围 PB-10 wydanie z 01.02.2021 r. | na podstawie testu kuwetowego Hach- Lange LCK 653","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"硫化物浓度"},{"_id":"6a7d78b70636ba417e41a178","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Ścieki, wody opadowe, wody roztopowe, woda","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, wody opadowe, wody roztopowe, woda Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, wody opadowe, wody roztopowe, woda Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Wastewater, rainwater, snowmelt water, water Total suspended solids (TSS) Gravimetric method Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater, rainwater, snowmelt water, water","lab_section_zh":"实验室","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"废水、雨水、融雪水、水 总悬浮物 重量法 实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"废水、雨水、融雪水、水"},{"_id":"6a7d78b70636ba417e41a179","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 – 7000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 7000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (100 – 7000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (100 – 7000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 – 7000) μS/cm"}],"search_en":"Water, wastewater Electrical conductivity Conductometric method Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 7000) μS/cm"}],"search_zh":"水、废水 电导率 电导法 实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a7d78b70636ba417e41a17a","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Water, wastewater pH Potentiometric method Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、废水 pH 值 电位法 实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a7d78b70636ba417e41a17b","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/l"}],"search_en":"Water, wastewater Chloride concentration Titrimetric method Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a7d78b70636ba417e41a17c","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10,0 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10,0 – 500) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (10,0 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow\nZakres (10,0 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10,0 – 500) mg/l"}],"search_en":"Water, wastewater Sulfate concentration Gravimetric method Laboratory Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10,0 – 500) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 重量法 实验室 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a7d78b70636ba417e41a17d","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,02 – 15) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,02 – 15) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie żelaza\nZakres (0,02 – 15) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, scieki Stezenie zelaza\nZakres (0,02 – 15) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,02 – 15) mg/l"}],"search_en":"Water, wastewater Iron concentration Spectrophotometric method Laboratory Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 15) mg/l"}],"search_zh":"水、废水 铁浓度 分光光度法 实验室 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7d78b70636ba417e41a17e","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(0,4 – 20) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna\nZakres (0,4 – 20) mmol/l\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001 + Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001 + Ap1:2004"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zasadowość ogólna\nZakres (0,4 – 20) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001 + Ap1:2004 Woda, scieki Zasadowosc ogolna\nZakres (0,4 – 20) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001 + Ap1:2004","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(0,4 – 20) mmol/l"}],"search_en":"Water, wastewater Total alkalinity Titrimetric method Laboratory Range PN-EN ISO 9963-1:2001 + Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,4 – 20) mmol/l"}],"search_zh":"水、废水 总碱度 滴定法 实验室 范围 PN-EN ISO 9963-1:2001 + Ap1:2004","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"总碱度"},{"_id":"6a7d78b70636ba417e41a17f","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,05 – 1,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,05 – 1,5) mg/l\nMetoda spektrofotometryczna","reference":"PB-05 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 349","norm_bases":["PB-05 wydanie z 7.05.2013 r.","na podstawie testu kuwetowego Hach-Lange LCK 349"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,05 – 1,5) mg/l\nMetoda spektrofotometryczna PB-05 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 349 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,05 – 1,5) mg/l\nMetoda spektrofotometryczna PB-05 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 349","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,05 – 1,5) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Laboratory Range PB-05 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 349","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 1,5) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 实验室 范围 PB-05 wydanie z 7.05.2013 r. | na podstawie testu kuwetowego Hach-Lange LCK 349","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7d78b70636ba417e41a180","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,010– 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,010– 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,010– 20,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,010– 20,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,010– 20,0) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Laboratory Range PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,010– 20,0) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 实验室 范围 PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7d78b70636ba417e41a181","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","parameters":[{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand – BOD5","parameters_en":[{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand – BOD5 Optical method Laboratory Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 光学法 实验室 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a7d78b70636ba417e41a182","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda optyczna","reference":"PN-EN 1899-2:2002 z wyłączeniem punktu 7.2 I-19 wydanie z 31.03.2009 r.","norm_bases":["PN-EN 1899-2:2002 z wyłączeniem punktu 7.2 I-19 wydanie z 31.03.2009 r."],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wyłączeniem punktu 7.2 I-19 wydanie z 31.03.2009 r. Woda, scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wylaczeniem punktu 7.2 I-19 wydanie z 31.03.2009 r.","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Biochemical oxygen demand – BOD5","parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand – BOD5 Optical method Laboratory Range PN-EN 1899-2:2002 z wyłączeniem punktu 7.2 I-19 wydanie z 31.03.2009 r.","technique_en":"Optical method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 光学法 实验室 范围 PN-EN 1899-2:2002 z wyłączeniem punktu 7.2 I-19 wydanie z 31.03.2009 r.","technique_zh":"光学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a7d78b70636ba417e41a183","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","lab_section_zh":"实验室","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7d78b70636ba417e41a184","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"P N - E N ISO 5667-13:2011","norm_bases":["P N - E N ISO 5667-13:2011"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych i fizycznych P N - E N ISO 5667-13:2011 Osady sciekowe Pobieranie probek do badan chemicznych i fizycznych P N - E N ISO 5667-13:2011","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Sewage sludge Sampling for chemical and physical testing Laboratory P N - E N ISO 5667-13:2011","test_object_en":"Sewage sludge","lab_section_zh":"实验室","methodology_zh":"化学与物理检测用样品采集","search_zh":"污泥 化学与物理检测用样品采集 实验室 P N - E N ISO 5667-13:2011","test_object_zh":"污泥"},{"_id":"6a7d78b70636ba417e41a185","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha pozostałość / zawartość wody","parameters":[{"name":"Zakres","range":"(1,00 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość / zawartość wody\nZakres (1,00 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02 metoda A","norm_bases":["PN-EN 15934:2013-02 metoda A"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha pozostałość / zawartość wody\nZakres (1,00 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A Osady sciekowe Sucha pozostalosc / zawartosc wody\nZakres (1,00 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 metoda A","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Dry residue / water content","parameters_en":[{"name":"Range","range":"(1,00 – 99,0) %"}],"search_en":"Sewage sludge Dry residue / water content Gravimetric method Laboratory Range PN-EN 15934:2013-02 metoda A","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,00 – 99,0) %"}],"search_zh":"污泥 干残渣/水分含量 重量法 实验室 范围 PN-EN 15934:2013-02 metoda A","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干残渣/水分含量"},{"_id":"6a7d78b70636ba417e41a186","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Straty przy prażeniu suchej masy (LOI)/ Pozostałość po prażeniu","parameters":[{"name":"Zakres","range":"(1,00 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Straty przy prażeniu suchej masy (LOI)/ Pozostałość po prażeniu\nZakres (1,00 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Straty przy prażeniu suchej masy (LOI)/ Pozostałość po prażeniu\nZakres (1,00 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe Straty przy prazeniu suchej masy (LOI)/ Pozostalosc po prazeniu\nZakres (1,00 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Loss on ignition of dry matter (LOI)/ Residue on ignition","parameters_en":[{"name":"Range","range":"(1,00 – 99,0) %"}],"search_en":"Sewage sludge Loss on ignition of dry matter (LOI)/ Residue on ignition Gravimetric method Laboratory Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(1,00 – 99,0) %"}],"search_zh":"污泥 重量法 实验室 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"污泥"},{"_id":"6a7d78b70636ba417e41a187","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH – w H2O","parameters":[{"name":"Zakres","range":"2,0 – 13,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH – w H2O\nZakres 2,0 – 13,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH – w H2O\nZakres 2,0 – 13,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH – w H2O\nZakres 2,0 – 13,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"pH – in H2O","parameters_en":[{"name":"Range","range":"2,0 – 13,0"}],"search_en":"Sewage sludge pH – in H2O Potentiometric method Laboratory Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"2,0 – 13,0"}],"search_zh":"污泥 pH — 于 H2O 中 电位法 实验室 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥","methodology_zh":"pH — 于 H2O 中"},{"_id":"6a7d78b70636ba417e41a188","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(100 – 10000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (100 – 10000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawiesiny ogólne\nZakres (100 – 10000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Osady sciekowe Zawiesiny ogolne\nZakres (100 – 10000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(100 – 10000) mg/l"}],"search_en":"Sewage sludge Total suspended solids (TSS) Gravimetric method Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(100 – 10000) mg/l"}],"search_zh":"污泥 总悬浮物 重量法 实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污泥"},{"_id":"6a7d78b70636ba417e41a189","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Objętość względna","parameters":[{"name":"Zakres","range":"(10 – 1000) ml/l"}],"technique":"Metoda objętościowa","techniques":["Metoda objętościowa"],"computed":[],"activity":"Objętość względna\nZakres (10 – 1000) ml/l\nMetoda objętościowa","reference":"PN-EN 14702-1:2008","norm_bases":["PN-EN 14702-1:2008"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Objętość względna\nZakres (10 – 1000) ml/l\nMetoda objętościowa PN-EN 14702-1:2008 Osady sciekowe Objetosc wzgledna\nZakres (10 – 1000) ml/l\nMetoda objetosciowa PN-EN 14702-1:2008","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Relative volume","parameters_en":[{"name":"Range","range":"(10 – 1000) ml/l"}],"search_en":"Sewage sludge Relative volume Volumetric method Laboratory Range PN-EN 14702-1:2008","technique_en":"Volumetric method","test_object_en":"Sewage sludge","lab_section_zh":"实验室","parameters_zh":[{"name":"范围","range":"(10 – 1000) ml/l"}],"search_zh":"污泥 相对体积 容量法 实验室 范围 PN-EN 14702-1:2008","test_object_zh":"污泥","technique_zh":"容量法","methodology_zh":"相对体积"},{"_id":"6a7d78b70636ba417e41a18a","lab_id":"69ad52a3de79e566650fb568","country":"PL","accr_number":"AB 1064","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Indeks objętościowy osadu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Indeks objętościowy osadu (z obliczeń)","reference":"PN-EN 14702-1:2008","norm_bases":["PN-EN 14702-1:2008"],"lab_section":"Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Indeks objętościowy osadu (z obliczeń) PN-EN 14702-1:2008 Osady sciekowe Indeks objetosciowy osadu (z obliczen) PN-EN 14702-1:2008","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory","methodology_en":"Sludge volume index (calculated)","search_en":"Sewage sludge Sludge volume index (calculated) Laboratory PN-EN 14702-1:2008","test_object_en":"Sewage sludge","lab_section_zh":"实验室","search_zh":"污泥 污泥容积指数（由计算得出） 实验室 PN-EN 14702-1:2008","test_object_zh":"污泥","methodology_zh":"污泥容积指数（由计算得出）"}],"has_pdf":true}