🇵🇱 GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA PL

PCA AB 106 • Warszawa, Poland • 34 methods

Water & wastewaterEnvironmentElectronics & EMC

GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA is a laboratory accredited by PCA under number AB 106 (Warszawa, Poland). Its accreditation scope covers 34 test methods in the following areas: Water & wastewater, Environment, Electronics & EMC. Test objects include: Water, wastewater, Water, Environment – electromagnetic field in the vicinity of electric pow…, Soil. Most frequently used techniques: Spectrophotometric method, Direct measurement method, Optical method.

At a glance

  • Accreditation number: PCA AB 106
  • Methods in scope: 34
  • Types of test objects: 9
  • Techniques used: 16
  • City: Warszawa, Poland
Accreditation number
AB 106
Accreditation body
PCA
Address
ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W KIELCACH, Al. IX Wieków Kielc 3
City
Warszawa, Poland

What this laboratory tests (9)

Analytical techniques used (16)

Laboratory sections (3)

Laboratory locations

Accreditation scope — test methods (34)

No. Test object Methodology / Parameters Technique Reference document
PRACOWNIA TERENOWA
1 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (25 - 130) dB
Direct measurement method Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) - z wyłączeniem punktu F
2 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) - z wyłączeniem punktu F
3 Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength:
in the frequency range 50 Hz Range (1 - 30 000) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
4 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density:
in the frequency range 50 Hz Range 1 µT - 10 mT
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
5 Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength
in the frequency range 50 Hz (calculated)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
6 Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Electric field strength:
w zakresie częstotliwości od 10 MHz do 60 GHz Range (0,3 - 200) V/m
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
7 Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Magnetic field strength
w zakresie częstotliwości od 10 MHz do 60 GHz (z obliczeń)
Regulated area: Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
8 Water Water sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5; 7.6; 8.2
9 Wastewater Sampling of wastewater for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
10 Soil Sampling for chemical and physical testing PN-ISO 10381-5:2009
11 Soil pH in KCl
Range (4,0 - 9,0)
Potentiometric method PN-EN ISO 10390:2022-09
PRACOWNIA TERENOWA; badania wykonywane poza siedzibą laboratorium
12 Water Temperature
Range (0,0 - 50,0) 0C
PN-77/C-04584
13 Wastewater Temperature
Range (0,0 - 50,0) 0C
PN-77/C-04584
14 Water, wastewater pH
Range (2,0 - 12,0)
Potentiometric method PN-EN ISO 10523:2012
15 Water, wastewater Electrical conductivity
Range (10,0 - 10000) µS/cm
Conductometric method PN-EN 27888:1999
16 Water Dissolved oxygen concentration
Range (0,5 - 15,0) mg/l O2
Optical method ISO 17289:2014
PRACOWNIA W KIELCACH
17 Water, wastewater Nitrite nitrogen concentration
Range (0,002 - 20,0) mg/l
Spectrophotometric method PN-EN 26777:1999
18 Water, wastewater Kjeldahl nitrogen concentration
Range (0,30 - 500) mg/l
Titrimetric method PN-EN 25663:2001
19 Water, wastewater Kjeldahl nitrogen concentration
Range (1,00 - 500) mg/l
Potentiometric titration method PN-EN 25663:2001
20 Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14.
21 Water, wastewater Biochemical oxygen demand
BZT5 , BZT2+5 Range (1 - 6000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12
22 Water, wastewater Biochemical oxygen demand
BZT5 , BZT2+5 Range (0,50 - 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
23 Water, wastewater Chemical oxygen demand - COD-Cr
Range (5,00 - 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005 z wyłączeniem pkt.10.3
24 Water, wastewater Anion concentrations
nitrate nitrogen (0,10 - 100) mg/l fluorides (0,10 - 20) mg/l chlorides (10 - 1000) mg/l sulfates (10 - 1000) mg/l nitrite nitrogen (0,002 - 20) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
25 Water, wastewater Mineral oil index (petroleum hydrocarbons)
Range (0,10 - 5000) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
26 Water, wastewater Total phosphorus concentration
Range (0,010 - 50,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 pkt.7 +Ap1:2010+Ap2:2010
27 Water, wastewater Total suspended solids (TSS)
Range (2,0 - 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
28 Water, wastewater Ammonium nitrogen concentration
Range (0,04 - 100) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
29 Water Phosphate phosphorus concentration
Range (0,010 - 20,0) mg/l P
Spectrophotometric method PN-EN ISO 6878:2006 pkt.4. +Ap1:2010+Ap2:2010
30 Soil Water permeability – coefficient of permeability
Range (1,0·10-9 - 1,0·10-4) m/s
Hydraulic gradient method PN-EN ISO 17892-11:2019-05
31 Soil, ground Particle size distribution Sieve method PN-EN ISO 17892-4:2017-01
32 Soil, ground Particle size distribution Hydrometer method PN-EN ISO 17892-4:2017-01
33 Soil, ground Water permeability – coefficient of permeability
Range (9,0·10-8 - 1,8·10-2) m/s (calculated from the particle size distribution curve – USBSC formula)
PB-04/KI wydanie 2 z dnia 09.12.2024 r.
34 Woda, ścieki *) Total organic carbon concentration
Range (2,0 - 1000) mg/l
Infrared spectrometry method (IR) PN-EN 1484:1999

Reference standards (26)

ISO 17289:2014
PB-04/KI wydanie 2 z dnia 09.12.2024 r.
PN-73/C-04576/14.
PN-77/C-04584
PN-EN 1484:1999
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 17892-11:2019-05
PN-EN ISO 17892-4:2017-01
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5; 7.6; 8.2
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 pkt.4. +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 pkt.7 +Ap1:2010+Ap2:2010
PN-EN ISO 9377-2:2003
PN-ISO 10381-5:2009
PN-ISO 15705:2005 z wyłączeniem pkt.10.3
PN-ISO 5667-10:2021-11
PN-ISO 7150-1:2002
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)
Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) - z wyłączeniem punktu F