{"lab":{"_id":"69ad52a3de79e566650fb11b","accr_number":"AB 106","country":"PL","accr_body":"PCA","address":"ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W KIELCACH, Al. IX Wieków Kielc 3","categories":["water","environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":34,"name":"GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_106.pdf"],"scope_summary":"","search_text":"główny inspektorat ochrony środowiska ul. chmielna 132/134, 00-805 warszawa, centralne laboratorium badawcze, oddział w kielcach, al. ix wieków kielc 3 environment metrology pharma electronics other water materials food automotive","status":"active","updated_at":"2026-03-08T14:50:14.528Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-14T12:21:11.487Z","parse_date":"2026-08-14T12:21:11.487Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://www.gov.pl/web/gios/kontakt-dla-obywateli","fields_of_testing":[{"codes":"C/28/P","pl":"Badania chemiczne i pobieranie próbek wody","en":"Chemical tests and sampling of water"},{"codes":"C/30/P","pl":"Badania chemiczne i pobieranie próbek ścieków","en":"Chemical tests and sampling of sewage"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne - hałas, pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise, electromagnetic field)"},{"codes":"N/28/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody","en":"Tests of physical properties and sampling of water"},{"codes":"N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek ścieków","en":"Tests of physical properties and sampling of sewage"},{"codes":"N/31/P","pl":"Badania właściwości fizycznych i pobieranie próbek gleby","en":"Tests of physical properties and sampling of soil"},{"codes":"N/31","pl":"Badania właściwości fizycznych gruntów","en":"Tests of physical properties of ground"}],"issue":{"no":"30","date":"17.04.2026"},"map_coord":[52.227738,20.992749],"map_geo":"nominatim-street","lab_locations":[{"name":"ODDZIAŁ W KIELCACH","address":"Al. IX Wieków Kielc 3","city":null,"postal":null},{"name":"PRACOWNIA TERENOWA","address":"Al. IX Wieków Kielc 3, 25-516 Kielce","city":"Kielce","postal":"25-516"},{"name":"PRACOWNIA W KIELCACH","address":"Al. IX Wieków Kielc 3, 25-516 Kielce","city":"Kielce","postal":"25-516"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/14/23fc93e8fff17dc3cdf58babbfe30969/AB%20106.pdf","has_en":true,"category_counts":{"water":21,"environment":13,"petro":1},"category_scores":{"water":12.6,"environment":4.83,"petro":0.03},"has_zh":true},"methods":[{"_id":"6a7f08371995264369d8e17c","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 - 130) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (25 - 130) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) - z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) - z wyłączeniem punktu F"],"lab_section":"PRACOWNIA TERENOWA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (25 - 130) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) - z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (25 - 130) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) - z wylaczeniem punktu F","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(25 - 130) dB"}],"search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) - z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25 - 130) dB"}],"search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) - z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a7f08371995264369d8e17d","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) - z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) - z wyłączeniem punktu F"],"lab_section":"PRACOWNIA TERENOWA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) - z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) - z wylaczeniem punktu F","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) - z wyłączeniem punktu F","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t. j. Dz.U. z 2023 r., poz. 1706) - z wyłączeniem punktu F","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a7f08371995264369d8e17e","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"(1 - 30 000) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres (1 - 30 000) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"PRACOWNIA TERENOWA","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres (1 - 30 000) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres (1 - 30 000) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"in the frequency range 50 Hz"},{"name":"Range","range":"(1 - 30 000) V/m"}],"search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength: Direct measurement method in the frequency range 50 Hz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围 50 Hz"},{"name":"范围","range":"(1 - 30 000) V/m"}],"search_zh":"环境 — 变电站与输电线路周围的电磁场 电场强度： 直接测量法 频率范围 50 Hz 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 — 变电站与输电线路周围的电磁场"},{"_id":"6a7f08371995264369d8e17f","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Indukcja magnetyczna:","parameters":[{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"1 µT - 10 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 1 µT - 10 mT\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"PRACOWNIA TERENOWA","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 1 µT - 10 mT\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Indukcja magnetyczna:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres 1 µT - 10 mT\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density:","parameters_en":[{"name":"in the frequency range 50 Hz"},{"name":"Range","range":"1 µT - 10 mT"}],"search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic flux density: Direct measurement method in the frequency range 50 Hz Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","parameters_zh":[{"name":"频率范围 50 Hz"},{"name":"范围","range":"1 µT - 10 mT"}],"search_zh":"环境 — 变电站与输电线路周围的电磁场 磁感应强度： 直接测量法 频率范围 50 Hz 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 — 变电站与输电线路周围的电磁场","methodology_zh":"磁感应强度："},{"_id":"6a7f08371995264369d8e180","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","methodology":"Natężenie pola magnetycznego","parameters":[{"name":"w zakresie częstotliwości 50 Hz (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego\nw zakresie częstotliwości 50 Hz (z obliczeń)","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"PRACOWNIA TERENOWA","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola magnetycznego\nw zakresie częstotliwości 50 Hz (z obliczeń) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola magnetycznego\nw zakresie czestotliwosci 50 Hz (z obliczen) Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength","parameters_en":[{"name":"in the frequency range 50 Hz (calculated)"}],"search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength in the frequency range 50 Hz (calculated) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","search_zh":"环境 — 变电站与输电线路周围的电磁场 磁场强度 频率 50 Hz 范围内（由计算得出） Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","test_object_zh":"环境 — 变电站与输电线路周围的电磁场","methodology_zh":"磁场强度","parameters_zh":[{"name":"频率 50 Hz 范围内（由计算得出）"}]},{"_id":"6a7f08371995264369d8e181","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe","methodology":"Natężenie pola elektrycznego:","parameters":[{"name":"w zakresie częstotliwości od 10 MHz do 60 GHz"},{"name":"Zakres","range":"(0,3 - 200) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 60 GHz\nZakres (0,3 - 200) V/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"PRACOWNIA TERENOWA","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości od 10 MHz do 60 GHz\nZakres (0,3 - 200) V/m\nMetoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci od 10 MHz do 60 GHz\nZakres (0,3 - 200) V/m\nMetoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength:","parameters_en":[{"name":"w zakresie częstotliwości od 10 MHz do 60 GHz"},{"name":"Range","range":"(0,3 - 200) V/m"}],"search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Electric field strength: Direct measurement method Range Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_en":"Direct measurement method","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements","methodology_zh":"电场强度：","parameters_zh":[{"name":"w zakresie częstotliwości od 10 MHz do 60 GHz"},{"name":"范围","range":"(0,3 - 200) V/m"}],"search_zh":"环境 — 无线电通信设施周围的电磁场：宽带测量 电场强度： 直接测量法 范围 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 — 无线电通信设施周围的电磁场：宽带测量"},{"_id":"6a7f08371995264369d8e182","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe","methodology":"Natężenie pola magnetycznego","parameters":[{"name":"w zakresie częstotliwości od 10 MHz do 60 GHz (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Natężenie pola magnetycznego\nw zakresie częstotliwości od 10 MHz do 60 GHz (z obliczeń)","reference":"Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)"],"lab_section":"PRACOWNIA TERENOWA","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska.","flexible":false,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natężenie pola magnetycznego\nw zakresie częstotliwości od 10 MHz do 60 GHz (z obliczeń) Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natezenie pola magnetycznego\nw zakresie czestotliwosci od 10 MHz do 60 GHz (z obliczen) Zalacznik do Rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Magnetic field strength Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements","search_zh":"环境 — 无线电通信设施周围的电磁场：宽带测量 磁场强度 Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz. U. 2022 poz. 2630)","test_object_zh":"环境 — 无线电通信设施周围的电磁场：宽带测量","methodology_zh":"磁场强度"},{"_id":"6a7f08371995264369d8e183","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek wody do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek wody do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5; 7.6; 8.2","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5; 7.6; 8.2"],"lab_section":"PRACOWNIA TERENOWA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek wody do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5; 7.6; 8.2 Woda Pobieranie probek wody do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.5; 7.6; 8.2","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water sampling for chemical and physical testing","search_en":"Water Water sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5; 7.6; 8.2","test_object_en":"Water","search_zh":"水 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5; 7.6; 8.2","test_object_zh":"水"},{"_id":"6a7f08371995264369d8e184","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(0,0 - 50,0) 0C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (0,0 - 50,0) 0C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"PRACOWNIA TERENOWA; badania wykonywane poza siedzibą laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura\nZakres (0,0 - 50,0) 0C PN-77/C-04584 Woda Temperatura\nZakres (0,0 - 50,0) 0C PN-77/C-04584","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(0,0 - 50,0) 0C"}],"search_en":"Water Temperature Range PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,0 - 50,0) 0C"}],"search_zh":"水 温度 范围 PN-77/C-04584","test_object_zh":"水","methodology_zh":"温度"},{"_id":"6a7f08371995264369d8e185","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek ścieków do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek ścieków do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"PRACOWNIA TERENOWA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek ścieków do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek sciekow do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling of wastewater for chemical and physical testing","search_en":"Wastewater Sampling of wastewater for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","search_zh":"污水 用于化学与物理检验的废水采样 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水","methodology_zh":"用于化学与物理检验的废水采样"},{"_id":"6a7f08371995264369d8e186","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(0,0 - 50,0) 0C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (0,0 - 50,0) 0C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"PRACOWNIA TERENOWA; badania wykonywane poza siedzibą laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura\nZakres (0,0 - 50,0) 0C PN-77/C-04584 Scieki Temperatura\nZakres (0,0 - 50,0) 0C PN-77/C-04584","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(0,0 - 50,0) 0C"}],"search_en":"Wastewater Temperature Range PN-77/C-04584","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,0 - 50,0) 0C"}],"search_zh":"污水 温度 范围 PN-77/C-04584","test_object_zh":"污水","methodology_zh":"温度"},{"_id":"6a7f08371995264369d8e187","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"(2,0 - 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (2,0 - 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"PRACOWNIA TERENOWA; badania wykonywane poza siedzibą laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki pH\nZakres (2,0 - 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres (2,0 - 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(2,0 - 12,0)"}],"search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(2,0 - 12,0)"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a7f08371995264369d8e188","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10,0 - 10000) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10,0 - 10000) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"PRACOWNIA TERENOWA; badania wykonywane poza siedzibą laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (10,0 - 10000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (10,0 - 10000) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10,0 - 10000) µS/cm"}],"search_en":"Water, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10,0 - 10000) µS/cm"}],"search_zh":"水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a7f08371995264369d8e189","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 - 15,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 - 15,0) mg/l O2\nMetoda optyczna","reference":"ISO 17289:2014","norm_bases":["ISO 17289:2014"],"lab_section":"PRACOWNIA TERENOWA; badania wykonywane poza siedzibą laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie tlenu rozpuszczonego\nZakres (0,5 - 15,0) mg/l O2\nMetoda optyczna ISO 17289:2014 Woda Stezenie tlenu rozpuszczonego\nZakres (0,5 - 15,0) mg/l O2\nMetoda optyczna ISO 17289:2014","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 - 15,0) mg/l O2"}],"search_en":"Water Dissolved oxygen concentration Optical method Range ISO 17289:2014","technique_en":"Optical method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,5 - 15,0) mg/l O2"}],"search_zh":"水 溶解氧浓度 光学法 范围 ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水","methodology_zh":"溶解氧浓度"},{"_id":"6a7f08371995264369d8e18a","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Gleba","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 10381-5:2009","norm_bases":["PN-ISO 10381-5:2009"],"lab_section":"PRACOWNIA TERENOWA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 10381-5:2009 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-ISO 10381-5:2009","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Soil Sampling for chemical and physical testing PN-ISO 10381-5:2009","test_object_en":"Soil","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-ISO 10381-5:2009","test_object_zh":"土壤"},{"_id":"6a7f08371995264369d8e18b","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Gleba","methodology":"pH w KCl","parameters":[{"name":"Zakres","range":"(4,0 - 9,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH w KCl\nZakres (4,0 - 9,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"PRACOWNIA TERENOWA","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba pH w KCl\nZakres (4,0 - 9,0)\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH w KCl\nZakres (4,0 - 9,0)\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH in KCl","parameters_en":[{"name":"Range","range":"(4,0 - 9,0)"}],"search_en":"Soil pH in KCl Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(4,0 - 9,0)"}],"search_zh":"土壤 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤"},{"_id":"6a7f08371995264369d8e18c","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,002 - 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,002 - 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"PRACOWNIA W KIELCACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,002 - 20,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,002 - 20,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,002 - 20,0) mg/l"}],"search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,002 - 20,0) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7f08371995264369d8e18d","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,30 - 500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,30 - 500) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"PRACOWNIA W KIELCACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (0,30 - 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (0,30 - 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,30 - 500) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,30 - 500) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a7f08371995264369d8e18e","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1,00 - 500) mg/l"}],"technique":"Metoda miareczkowania potencjometrycznego","techniques":["Metoda miareczkowania potencjometrycznego"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,00 - 500) mg/l\nMetoda miareczkowania potencjometrycznego","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"PRACOWNIA W KIELCACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (1,00 - 500) mg/l\nMetoda miareczkowania potencjometrycznego PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (1,00 - 500) mg/l\nMetoda miareczkowania potencjometrycznego PN-EN 25663:2001","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,00 - 500) mg/l"}],"search_en":"Water, wastewater Kjeldahl nitrogen concentration Potentiometric titration method Range PN-EN 25663:2001","technique_en":"Potentiometric titration method","test_object_en":"Water, wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,00 - 500) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 电位滴定法 范围 PN-EN 25663:2001","technique_zh":"电位滴定法","test_object_zh":"水、废水"},{"_id":"6a7f08371995264369d8e18f","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14.","norm_bases":["PN-73/C-04576/14."],"lab_section":"PRACOWNIA W KIELCACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14. Woda, scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14.","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14.","test_object_en":"Water, wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PN-73/C-04576/14.","test_object_zh":"水、废水"},{"_id":"6a7f08371995264369d8e190","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5 , BZT2+5"},{"name":"Zakres","range":"(1 - 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5 , BZT2+5\nZakres (1 - 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"PRACOWNIA W KIELCACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5 , BZT2+5\nZakres (1 - 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5 , BZT2+5\nZakres (1 - 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BZT5 , BZT2+5"},{"name":"Range","range":"(1 - 6000) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand Optical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Water, wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5 , BZT2+5"},{"name":"范围","range":"(1 - 6000) mg/l O2"}],"search_zh":"水、废水 生化需氧量 光学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、废水"},{"_id":"6a7f08371995264369d8e191","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5 , BZT2+5"},{"name":"Zakres","range":"(0,50 - 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5 , BZT2+5\nZakres (0,50 - 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"PRACOWNIA W KIELCACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5 , BZT2+5\nZakres (0,50 - 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5 , BZT2+5\nZakres (0,50 - 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BZT5 , BZT2+5"},{"name":"Range","range":"(0,50 - 6,0) mg/l O2"}],"search_en":"Water, wastewater Biochemical oxygen demand Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5 , BZT2+5"},{"name":"范围","range":"(0,50 - 6,0) mg/l O2"}],"search_zh":"水、废水 生化需氧量 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a7f08371995264369d8e192","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(5,00 - 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (5,00 - 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005 z wyłączeniem pkt.10.3","norm_bases":["PN-ISO 15705:2005 z wyłączeniem pkt.10.3"],"lab_section":"PRACOWNIA W KIELCACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (5,00 - 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 z wyłączeniem pkt.10.3 Woda, scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (5,00 - 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 z wylaczeniem pkt.10.3","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(5,00 - 10000) mg/l O2"}],"search_en":"Water, wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005 z wyłączeniem pkt.10.3","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(5,00 - 10000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005 z wyłączeniem pkt.10.3","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a7f08371995264369d8e193","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie anionów","parameters":[{"name":"azot azotanowy","range":"(0,10 - 100) mg/l"},{"name":"fluorki","range":"(0,10 - 20) mg/l"},{"name":"chlorki","range":"(10 - 1000) mg/l"},{"name":"siarczany","range":"(10 - 1000) mg/l"},{"name":"azot azotynowy","range":"(0,002 - 20) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nazot azotanowy (0,10 - 100) mg/l\nfluorki (0,10 - 20) mg/l\nchlorki (10 - 1000) mg/l\nsiarczany (10 - 1000) mg/l\nazot azotynowy (0,002 - 20) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"PRACOWNIA W KIELCACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie anionów\nZakres:\nazot azotanowy (0,10 - 100) mg/l\nfluorki (0,10 - 20) mg/l\nchlorki (10 - 1000) mg/l\nsiarczany (10 - 1000) mg/l\nazot azotynowy (0,002 - 20) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, scieki Stezenie anionow\nZakres:\nazot azotanowy (0,10 - 100) mg/l\nfluorki (0,10 - 20) mg/l\nchlorki (10 - 1000) mg/l\nsiarczany (10 - 1000) mg/l\nazot azotynowy (0,002 - 20) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"nitrate nitrogen","range":"(0,10 - 100) mg/l"},{"name":"fluorides","range":"(0,10 - 20) mg/l"},{"name":"chlorides","range":"(10 - 1000) mg/l"},{"name":"sulfates","range":"(10 - 1000) mg/l"},{"name":"nitrite nitrogen","range":"(0,002 - 20) mg/l"}],"search_en":"Water, wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) nitrate nitrogen fluorides chlorides sulfates nitrite nitrogen PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, wastewater","methodology_zh":"阴离子浓度","search_zh":"水、废水 阴离子浓度 离子色谱-电导检测法（IC-CD） 硝酸盐氮 氟化物 氯化物 硫酸盐 亚硝酸盐氮 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、废水","parameters_zh":[{"name":"硝酸盐氮","range":"(0,10 - 100) mg/l"},{"name":"氟化物","range":"(0,10 - 20) mg/l"},{"name":"氯化物","range":"(10 - 1000) mg/l"},{"name":"硫酸盐","range":"(10 - 1000) mg/l"},{"name":"亚硝酸盐氮","range":"(0,002 - 20) mg/l"}]},{"_id":"6a7f08371995264369d8e194","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Indeks oleju mineralnego (węglowodory ropopochodne)","parameters":[{"name":"Zakres","range":"(0,10 - 5000) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego (węglowodory ropopochodne)\nZakres (0,10 - 5000) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"PRACOWNIA W KIELCACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Indeks oleju mineralnego (węglowodory ropopochodne)\nZakres (0,10 - 5000) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Indeks oleju mineralnego (weglowodory ropopochodne)\nZakres (0,10 - 5000) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index (petroleum hydrocarbons)","parameters_en":[{"name":"Range","range":"(0,10 - 5000) mg/l"}],"search_en":"Water, wastewater Mineral oil index (petroleum hydrocarbons) Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, wastewater","parameters_zh":[{"name":"范围","range":"(0,10 - 5000) mg/l"}],"search_zh":"水、废水 矿物油指数（石油类烃） 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水","methodology_zh":"矿物油指数（石油类烃）"},{"_id":"6a7f08371995264369d8e195","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,010 - 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,010 - 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt.7 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt.7 +Ap1:2010+Ap2:2010"],"lab_section":"PRACOWNIA W KIELCACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,010 - 50,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.7 +Ap1:2010+Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,010 - 50,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.7 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,010 - 50,0) mg/l"}],"search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt.7 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,010 - 50,0) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt.7 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7f08371995264369d8e196","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 - 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 - 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"PRACOWNIA W KIELCACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 - 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 - 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 - 1000) mg/l"}],"search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 - 1000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a7f08371995264369d8e197","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,04 - 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,04 - 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"PRACOWNIA W KIELCACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,04 - 100) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,04 - 100) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,04 - 100) mg/l"}],"search_en":"Water, wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 - 100) mg/l"}],"search_zh":"水、废水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a7f08371995264369d8e198","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie fosforu fosforanowego","parameters":[{"name":"Zakres","range":"(0,010 - 20,0) mg/l P"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu fosforanowego\nZakres (0,010 - 20,0) mg/l P\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt.4. +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt.4. +Ap1:2010+Ap2:2010"],"lab_section":"PRACOWNIA W KIELCACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie fosforu fosforanowego\nZakres (0,010 - 20,0) mg/l P\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.4. +Ap1:2010+Ap2:2010 Woda Stezenie fosforu fosforanowego\nZakres (0,010 - 20,0) mg/l P\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.4. +Ap1:2010+Ap2:2010","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphate phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,010 - 20,0) mg/l P"}],"search_en":"Water Phosphate phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt.4. +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,010 - 20,0) mg/l P"}],"search_zh":"水 磷酸盐磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt.4. +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"磷酸盐磷浓度"},{"_id":"6a7f08371995264369d8e199","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Gleba","methodology":"Wodoprzepuszczalność – współczynnik filtracji","parameters":[{"name":"Zakres","range":"(1,0·10-9 - 1,0·10-4) m/s"}],"technique":"Metoda spadków hydraulicznych","techniques":["Metoda spadków hydraulicznych"],"computed":[],"activity":"Wodoprzepuszczalność – współczynnik filtracji\nZakres (1,0·10-9 - 1,0·10-4) m/s\nMetoda spadków hydraulicznych","reference":"PN-EN ISO 17892-11:2019-05","norm_bases":["PN-EN ISO 17892-11:2019-05"],"lab_section":"PRACOWNIA W KIELCACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba Wodoprzepuszczalność – współczynnik filtracji\nZakres (1,0·10-9 - 1,0·10-4) m/s\nMetoda spadków hydraulicznych PN-EN ISO 17892-11:2019-05 Gleba Wodoprzepuszczalnosc – wspolczynnik filtracji\nZakres (1,0·10-9 - 1,0·10-4) m/s\nMetoda spadkow hydraulicznych PN-EN ISO 17892-11:2019-05","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water permeability – coefficient of permeability","parameters_en":[{"name":"Range","range":"(1,0·10-9 - 1,0·10-4) m/s"}],"search_en":"Soil Water permeability – coefficient of permeability Hydraulic gradient method Range PN-EN ISO 17892-11:2019-05","technique_en":"Hydraulic gradient method","test_object_en":"Soil","parameters_zh":[{"name":"范围","range":"(1,0·10-9 - 1,0·10-4) m/s"}],"search_zh":"土壤 透水性 － 渗透系数 水力坡降法 范围 PN-EN ISO 17892-11:2019-05","test_object_zh":"土壤","methodology_zh":"透水性 － 渗透系数","technique_zh":"水力坡降法"},{"_id":"6a7f08371995264369d8e19a","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Skład granulometryczny","parameters":[],"technique":"Metoda sitowa","techniques":["Metoda sitowa"],"computed":[],"activity":"Skład granulometryczny\nMetoda sitowa","reference":"PN-EN ISO 17892-4:2017-01","norm_bases":["PN-EN ISO 17892-4:2017-01"],"lab_section":"PRACOWNIA W KIELCACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Skład granulometryczny\nMetoda sitowa PN-EN ISO 17892-4:2017-01 Gleba, grunty Sklad granulometryczny\nMetoda sitowa PN-EN ISO 17892-4:2017-01","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Particle size distribution","search_en":"Soil, ground Particle size distribution Sieve method PN-EN ISO 17892-4:2017-01","technique_en":"Sieve method","test_object_en":"Soil, ground","search_zh":"土壤、土体 粒度组成 筛析法 PN-EN ISO 17892-4:2017-01","test_object_zh":"土壤、土体","methodology_zh":"粒度组成","technique_zh":"筛析法"},{"_id":"6a7f08371995264369d8e19b","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Skład granulometryczny","parameters":[],"technique":"Metoda areometryczna","techniques":["Metoda areometryczna"],"computed":[],"activity":"Skład granulometryczny\nMetoda areometryczna","reference":"PN-EN ISO 17892-4:2017-01","norm_bases":["PN-EN ISO 17892-4:2017-01"],"lab_section":"PRACOWNIA W KIELCACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Skład granulometryczny\nMetoda areometryczna PN-EN ISO 17892-4:2017-01 Gleba, grunty Sklad granulometryczny\nMetoda areometryczna PN-EN ISO 17892-4:2017-01","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Particle size distribution","search_en":"Soil, ground Particle size distribution Hydrometer method PN-EN ISO 17892-4:2017-01","technique_en":"Hydrometer method","test_object_en":"Soil, ground","search_zh":"土壤、土体 粒度组成 比重计法 PN-EN ISO 17892-4:2017-01","test_object_zh":"土壤、土体","methodology_zh":"粒度组成","technique_zh":"比重计法"},{"_id":"6a7f08371995264369d8e19c","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Gleba, grunty","methodology":"Wodoprzepuszczalność – współczynnik filtracji","parameters":[{"name":"Zakres","range":"(9,0·10-8 - 1,8·10-2) m/s"},{"name":"(z obliczeń na podstawie krzywej uziarnienia – wzór USBSC)"}],"technique":null,"techniques":[],"computed":[],"activity":"Wodoprzepuszczalność – współczynnik filtracji\nZakres:\nZakres (9,0·10-8 - 1,8·10-2) m/s\n(z obliczeń na podstawie krzywej uziarnienia – wzór USBSC)","reference":"PB-04/KI wydanie 2 z dnia 09.12.2024 r.","norm_bases":["PB-04/KI wydanie 2 z dnia 09.12.2024 r."],"lab_section":"PRACOWNIA W KIELCACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gleba, grunty Wodoprzepuszczalność – współczynnik filtracji\nZakres:\nZakres (9,0·10-8 - 1,8·10-2) m/s\n(z obliczeń na podstawie krzywej uziarnienia – wzór USBSC) PB-04/KI wydanie 2 z dnia 09.12.2024 r. Gleba, grunty Wodoprzepuszczalnosc – wspolczynnik filtracji\nZakres:\nZakres (9,0·10-8 - 1,8·10-2) m/s\n(z obliczen na podstawie krzywej uziarnienia – wzor USBSC) PB-04/KI wydanie 2 z dnia 09.12.2024 r.","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water permeability – coefficient of permeability","parameters_en":[{"name":"Range","range":"(9,0·10-8 - 1,8·10-2) m/s"},{"name":"(calculated from the particle size distribution curve – USBSC formula)"}],"search_en":"Soil, ground Water permeability – coefficient of permeability Range (calculated from the particle size distribution curve – USBSC formula) PB-04/KI wydanie 2 z dnia 09.12.2024 r.","test_object_en":"Soil, ground","parameters_zh":[{"name":"范围","range":"(9,0·10-8 - 1,8·10-2) m/s"},{"name":"（依据颗粒级配曲线计算得出 － USBSC 公式）"}],"search_zh":"土壤、土体 透水性 － 渗透系数 范围 （依据颗粒级配曲线计算得出 － USBSC 公式） PB-04/KI wydanie 2 z dnia 09.12.2024 r.","test_object_zh":"土壤、土体","methodology_zh":"透水性 － 渗透系数"},{"_id":"6a7f08371995264369d8e19d","lab_id":"69ad52a3de79e566650fb11b","country":"PL","accr_number":"AB 106","accr_body":"PCA","test_object":"Woda, ścieki *)","methodology":"Stężenie ogólnego węgla organicznego","parameters":[{"name":"Zakres","range":"(2,0 - 1000) mg/l"}],"technique":"Metoda spektrometrii w podczerwieni (IR)","techniques":["Metoda spektrometrii w podczerwieni (IR)"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego\nZakres (2,0 - 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR)","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"PRACOWNIA W KIELCACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki *) Stężenie ogólnego węgla organicznego\nZakres (2,0 - 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999 Woda, scieki *) Stezenie ogolnego wegla organicznego\nZakres (2,0 - 1000) mg/l\nMetoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon concentration","parameters_en":[{"name":"Range","range":"(2,0 - 1000) mg/l"}],"search_en":"Total organic carbon concentration Infrared spectrometry method (IR) Range PN-EN 1484:1999","technique_en":"Infrared spectrometry method (IR)","parameters_zh":[{"name":"范围","range":"(2,0 - 1000) mg/l"}],"search_zh":"总有机碳浓度 红外光谱法（IR） 范围 PN-EN 1484:1999","methodology_zh":"总有机碳浓度","technique_zh":"红外光谱法（IR）"}],"has_pdf":true}