🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL

PCA AB 1051 • Giżycko, Poland • 35 methods

Water & wastewaterMicrobiology

PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 1051 (Giżycko, Poland). Its accreditation scope covers 35 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Water intended for human consumption, Wastewater, Water, Wastewater, Wastewater. Most frequently used techniques: Spectrophotometric method, Colilert-18 method, Electrochemical method.

At a glance

  • Accreditation number: PCA AB 1051
  • Methods in scope: 35
  • Types of test objects: 5
  • Techniques used: 12
  • City: Giżycko, Poland
Accreditation number
AB 1051
Accreditation body
PCA
Address
ul. Obwodowa 6, 11-500 Giżycko, LABORATORIUM ŚRODOWISKOWE, Bystry 25
City
Giżycko, Poland

What this laboratory tests (5)

Analytical techniques used (12)

Laboratory locations

Accreditation scope — test methods (35)

No. Test object Methodology / Parameters Technique Reference document
Environmental Laboratory; Bystry 25, 11-500 Giżycko
1 Wastewater Sampling for chemical and physical testing
Temperature Range (0,0 – 45,0)°C
Manual method; Automatic method P N -ISO 5667-10:2021-11 | PN-77/C-04584
2 Wastewater Nitrate nitrogen concentration
Range (3,00 - 50,0) mg/l
Spectrophotometric method PB-34 wydanie 3 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.09713.0001
3 Wastewater Biochemical oxygen demand
BOD5 Range (6 - 6000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
4 Water intended for human consumption Sampling for chemical and physical testing
Temperature Range (0,0 – 45,0)°C
P N - I SO 5667-5:2017-10 | PN-77/C-04584
5 Water intended for human consumption True colour
Range (3,0 - 150) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06
6 Water intended for human consumption Turbidity
Range (0,10 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
7 Water intended for human consumption Manganese concentration
Range (0,010 - 1,0) mg/l
Spectrophotometric method PB-26 wydanie 4 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14770.0001
8 Water intended for human consumption Iron concentration
Range (0,040 - 5,0) mg/l
Spectrophotometric method PB-27 wydanie 4 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14761.0001
9 Water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (10,6 - 537) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
10 Water intended for human consumption Electrical conductivity
Range (10,0 – 2500) μS/cm
Conductometric method PN-EN 27888:1999
11 Water, Wastewater Total suspended solids (TSS)
Range (2,0 - 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
12 Water, Wastewater Biochemical oxygen demand - BOD5
Range (1,0 - 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
13 Water, Wastewater Total phosphorus concentration
Range (0,10 - 25,0) mg/l
Spectrophotometric method PB-12 wydanie 5 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14543.0001 i nr 1.14729.0001
14 Water, Wastewater Total nitrogen concentration
Range (0,50 - 150) mg/l
Spectrophotometric method PB-08 wydanie 5 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14537.0001 i nr 1.14763.0001
15 Water, Wastewater Biochemical oxygen demand
BOD5 Range (6 - 6000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12
16 Water, Wastewater Biochemical oxygen demand
BOD5 Range (1,0 – 6,0) mg/l O2
Optical method PN-EN 1899-2:2002 z wyłączeniem pkt. 7.2
17 Water, Water intended for human consumption, Wastewater Chemical oxygen demand COD-Cr
Range (6,5 - 10000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
18 Water, Water intended for human consumption, Wastewater pH
Range 4,0 - 10,0
Potentiometric method PN-EN ISO 10523:2012
19 Water intended for human consumption, Wastewater Phosphate concentration
Range (0,10 - 15,0) mg/l
Spectrophotometric method PB-13 wydanie 5 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14848.0001
20 Water intended for human consumption, Wastewater Ammonium nitrogen concentration
Range (0,026 - 157) mg/l
Spectrophotometric method PB-05 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14752.0001
21 Water intended for human consumption, Wastewater Ammonium ion concentration
Range (0,033 - 200) mg/l
Spectrophotometric method PB-05 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14752.0001
22 Water intended for human consumption, Wastewater Nitrite nitrogen concentration
Range (0,009 - 0,76) mg/l
Spectrophotometric method PB-07 wydanie 7 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14776.0001
23 Water intended for human consumption, Wastewater Nitrite concentration
Range (0,030 – 2,5) mg/l
Spectrophotometric method PB-07 wydanie 7 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14776.0001
24 Water intended for human consumption, Wastewater Nitrate nitrogen concentration
Range (0,14 - 3,00) mg/l
Spectrophotometric method PB-06 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14556.0001
25 Water intended for human consumption, Wastewater Nitrate concentration
Range (0,6 – 13,3) mg/l
Spectrophotometric method PB-06 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14556.0001
26 Water intended for human consumption, Wastewater Sulfate concentration
Range (9,0 - 250) mg/l
Spectrophotometric method PB-16 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14548.0001
27 Water intended for human consumption, Wastewater Chloride concentration
Range (9,0 – 250) mg/l
Spectrophotometric method PB-10 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14730.0001
28 Water intended for human consumption, Wastewater Chloride concentration
Range (5,0 - 250) mg/l
Titrimetric method PN-ISO 9297:1994
29 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
30 Water intended for human consumption Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
31 Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
32 Water intended for human consumption Coliform bacteria and Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
33 Water intended for human consumption Enterococci (faecal streptococci) count Membrane filtration method PN-EN ISO 7899-2:2004
34 Water intended for human consumption Most probable number of coliform bacteria Colilert-18 method PN-EN ISO 9308-2:2014-06
35 Water intended for human consumption Most probable number, Escherichia coli Colilert-18 method PN-EN ISO 9308-2:2014-06

Reference standards (41)

P N - I SO 5667-5:2017-10
P N -ISO 5667-10:2021-11
PB-05 wydanie 6 z dnia 02.01.2026 r.
PB-06 wydanie 6 z dnia 02.01.2026 r.
PB-07 wydanie 7 z dnia 02.01.2026 r.
PB-08 wydanie 5 z dnia 02.01.2026 r.
PB-10 wydanie 6 z dnia 02.01.2026 r.
PB-12 wydanie 5 z dnia 02.01.2026 r.
PB-13 wydanie 5 z dnia 02.01.2026 r.
PB-16 wydanie 6 z dnia 02.01.2026 r.
PB-26 wydanie 4 z dnia 02.01.2026 r.
PB-27 wydanie 4 z dnia 02.01.2026 r.
PB-34 wydanie 3 z dnia 02.01.2026 r.
PN-77/C-04584
PN-EN 1899-2:2002
PN-EN 1899-2:2002 z wyłączeniem pkt. 7.2
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 6059:1999
PN-ISO 9297:1994
na podstawie testu kuwetowego Merck nr 1.09713.0001
na podstawie testu kuwetowego Merck nr 1.14537.0001 i nr 1.14763.0001
na podstawie testu kuwetowego Merck nr 1.14543.0001 i nr 1.14729.0001
na podstawie testu kuwetowego Merck nr 1.14548.0001
na podstawie testu kuwetowego Merck nr 1.14556.0001
na podstawie testu kuwetowego Merck nr 1.14730.0001
na podstawie testu kuwetowego Merck nr 1.14752.0001
na podstawie testu kuwetowego Merck nr 1.14761.0001
na podstawie testu kuwetowego Merck nr 1.14770.0001
na podstawie testu kuwetowego Merck nr 1.14776.0001
na podstawie testu kuwetowego Merck nr 1.14848.0001