{"lab":{"_id":"69ad52a3de79e566650fb556","accr_number":"AB 1051","country":"PL","accr_body":"PCA","address":"ul. Obwodowa 6, 11-500 Giżycko, LABORATORIUM ŚRODOWISKOWE, Bystry 25","categories":["water","microbiology"],"city":"Giżycko","imported_at":"2026-03-08T10:42:43.265Z","methods_count":35,"name":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1051.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo wodociągów i kanalizacji sp. z o.o. ul. obwodowa 6, 11-500 giżycko, laboratorium środowiskowe, bystry 25 water other pharma electronics microbiology","status":"active","updated_at":"2026-03-08T14:50:13.965Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T07:56:04.500Z","parse_date":"2026-08-13T07:56:04.500Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://pwikgizycko.pl/laboratorium.html","fields_of_testing":[{"codes":"C/28","pl":"Badania chemiczne wody","en":"Chemical tests of water"},{"codes":"C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of drinking water, sewage"},{"codes":"K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling of drinking water"},{"codes":"N/28","pl":"Badania właściwości fizycznych wody","en":"Tests of physical properties of water"},{"codes":"N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of drinking water, sewage"}],"issue":{"no":"19","date":"07.05.2026"},"map_coord":[54.028574,21.803564],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM ŚRODOWISKOWE","address":"AB 1051 11-500 Giżycko","city":"Giżycko","postal":"11-500"},{"name":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/6c57b42507b19981d7996ceac097742d/AB%201051.pdf","has_en":true,"category_counts":{"water":35,"microbiology":4},"category_scores":{"water":31.41,"microbiology":0.41},"has_zh":true,"lab_locations_zh":[{"name":"LABORATORIUM ŚRODOWISKOWE","address":"AB 1051 11-500 Giżycko","city":"Giżycko","postal":"11-500"},{"name":"环境实验室；Bystry 25, 11-500 Giżycko","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d78940636ba417e419f8e","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(0,0 – 45,0)°C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 45,0)°C\nMetoda manualna; Metoda automatyczna","reference":"P N -ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["P N -ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 45,0)°C\nMetoda manualna; Metoda automatyczna P N -ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 45,0)°C\nMetoda manualna; Metoda automatyczna P N -ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(0,0 – 45,0)°C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Environmental Laboratory; Bystry 25, 11-500 Giżycko Temperature Range P N -ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(0,0 – 45,0)°C"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 环境实验室；Bystry 25, 11-500 Giżycko 温度 范围 P N -ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"},{"_id":"6a7d78940636ba417e419f8f","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(3,00 - 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (3,00 - 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-34 wydanie 3 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.09713.0001","norm_bases":["PB-34 wydanie 3 z dnia 02.01.2026 r.","na podstawie testu kuwetowego Merck nr 1.09713.0001"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (3,00 - 50,0) mg/l\nMetoda spektrofotometryczna PB-34 wydanie 3 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.09713.0001 Scieki Stezenie azotu azotanowego\nZakres (3,00 - 50,0) mg/l\nMetoda spektrofotometryczna PB-34 wydanie 3 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.09713.0001","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(3,00 - 50,0) mg/l"}],"search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PB-34 wydanie 3 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.09713.0001","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(3,00 - 50,0) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PB-34 wydanie 3 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.09713.0001","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"},{"_id":"6a7d78940636ba417e419f90","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(6 - 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (6 - 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (6 - 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (6 - 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(6 - 6000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand Electrochemical method Environmental Laboratory; Bystry 25, 11-500 Giżycko BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(6 - 6000) mg/l O2"}],"search_zh":"污水 生化需氧量 电化学法 环境实验室；Bystry 25, 11-500 Giżycko BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"},{"_id":"6a7d78940636ba417e419f91","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(0,0 – 45,0)°C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 45,0)°C","reference":"P N - I SO 5667-5:2017-10 | PN-77/C-04584","norm_bases":["P N - I SO 5667-5:2017-10","PN-77/C-04584"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 45,0)°C P N - I SO 5667-5:2017-10 | PN-77/C-04584 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (0,0 – 45,0)°C P N - I SO 5667-5:2017-10 | PN-77/C-04584","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(0,0 – 45,0)°C"}],"search_en":"Water intended for human consumption Sampling for chemical and physical testing Environmental Laboratory; Bystry 25, 11-500 Giżycko Temperature Range P N - I SO 5667-5:2017-10 | PN-77/C-04584","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(0,0 – 45,0)°C"}],"search_zh":"生活饮用水 化学与物理检测用样品采集 环境实验室；Bystry 25, 11-500 Giżycko 温度 范围 P N - I SO 5667-5:2017-10 | PN-77/C-04584","test_object_zh":"生活饮用水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"},{"_id":"6a7d78940636ba417e419f92","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Barwa rzeczywista","parameters":[{"name":"Zakres","range":"(3,0 - 150) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa rzeczywista\nZakres (3,0 - 150) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Barwa rzeczywista\nZakres (3,0 - 150) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06 Woda do spozycia przez ludzi Barwa rzeczywista\nZakres (3,0 - 150) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"True colour","parameters_en":[{"name":"Range","range":"(3,0 - 150) mg/l Pt"}],"search_en":"Water intended for human consumption True colour Spectrophotometric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(3,0 - 150) mg/l Pt"}],"search_zh":"生活饮用水 分光光度法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"},{"_id":"6a7d78940636ba417e419f93","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 – 100) NTU"}],"search_en":"Water intended for human consumption Turbidity Nephelometric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 100) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 环境实验室；Bystry 25, 11-500 Giżycko 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"},{"_id":"6a7d78940636ba417e419f94","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,010 - 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,010 - 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-26 wydanie 4 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14770.0001","norm_bases":["PB-26 wydanie 4 z dnia 02.01.2026 r.","na podstawie testu kuwetowego Merck nr 1.14770.0001"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,010 - 1,0) mg/l\nMetoda spektrofotometryczna PB-26 wydanie 4 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14770.0001 Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,010 - 1,0) mg/l\nMetoda spektrofotometryczna PB-26 wydanie 4 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14770.0001","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,010 - 1,0) mg/l"}],"search_en":"Water intended for human consumption Manganese concentration Spectrophotometric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PB-26 wydanie 4 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14770.0001","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,010 - 1,0) mg/l"}],"search_zh":"生活饮用水 锰浓度 分光光度法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PB-26 wydanie 4 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14770.0001","technique_zh":"分光光度法","test_object_zh":"生活饮用水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"},{"_id":"6a7d78940636ba417e419f95","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,040 - 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,040 - 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-27 wydanie 4 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14761.0001","norm_bases":["PB-27 wydanie 4 z dnia 02.01.2026 r.","na podstawie testu kuwetowego Merck nr 1.14761.0001"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza\nZakres (0,040 - 5,0) mg/l\nMetoda spektrofotometryczna PB-27 wydanie 4 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14761.0001 Woda do spozycia przez ludzi Stezenie zelaza\nZakres (0,040 - 5,0) mg/l\nMetoda spektrofotometryczna PB-27 wydanie 4 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14761.0001","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,040 - 5,0) mg/l"}],"search_en":"Water intended for human consumption Iron concentration Spectrophotometric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PB-27 wydanie 4 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14761.0001","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,040 - 5,0) mg/l"}],"search_zh":"生活饮用水 铁浓度 分光光度法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PB-27 wydanie 4 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14761.0001","technique_zh":"分光光度法","test_object_zh":"生活饮用水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"},{"_id":"6a7d78940636ba417e419f96","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(10,6 - 537) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10,6 - 537) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10,6 - 537) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (10,6 - 537) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(10,6 - 537) mg/l CaCO3"}],"search_en":"Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(10,6 - 537) mg/l CaCO3"}],"search_zh":"生活饮用水 钙与镁总量（总硬度） 滴定法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"},{"_id":"6a7d78940636ba417e419f97","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10,0 – 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10,0 – 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (10,0 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (10,0 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10,0 – 2500) μS/cm"}],"search_en":"Water intended for human consumption Electrical conductivity Conductometric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10,0 – 2500) μS/cm"}],"search_zh":"生活饮用水 电导率 电导法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"},{"_id":"6a7d78940636ba417e419f98","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 - 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 - 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (2,0 - 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (2,0 - 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 - 1000) mg/l"}],"search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 - 1000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"},{"_id":"6a7d78940636ba417e419f99","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(1,0 - 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1,0 - 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1,0 - 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (1,0 - 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(1,0 - 6,0) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(1,0 - 6,0) mg/l O2"}],"search_zh":"水、污水 五日生化需氧量（BOD5） 电化学法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、污水","methodology_zh":"五日生化需氧量（BOD5）","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"},{"_id":"6a7d78940636ba417e419f9a","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,10 - 25,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,10 - 25,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-12 wydanie 5 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14543.0001 i nr 1.14729.0001","norm_bases":["PB-12 wydanie 5 z dnia 02.01.2026 r.","na podstawie testu kuwetowego Merck nr 1.14543.0001 i nr 1.14729.0001"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,10 - 25,0) mg/l\nMetoda spektrofotometryczna PB-12 wydanie 5 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14543.0001 i nr 1.14729.0001 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,10 - 25,0) mg/l\nMetoda spektrofotometryczna PB-12 wydanie 5 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14543.0001 i nr 1.14729.0001","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,10 - 25,0) mg/l"}],"search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PB-12 wydanie 5 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14543.0001 i nr 1.14729.0001","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,10 - 25,0) mg/l"}],"search_zh":"水、污水 总磷浓度 分光光度法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PB-12 wydanie 5 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14543.0001 i nr 1.14729.0001","technique_zh":"分光光度法","test_object_zh":"水、污水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"},{"_id":"6a7d78940636ba417e419f9b","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(0,50 - 150) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (0,50 - 150) mg/l\nMetoda spektrofotometryczna","reference":"PB-08 wydanie 5 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14537.0001 i nr 1.14763.0001","norm_bases":["PB-08 wydanie 5 z dnia 02.01.2026 r.","na podstawie testu kuwetowego Merck nr 1.14537.0001 i nr 1.14763.0001"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu ogólnego\nZakres (0,50 - 150) mg/l\nMetoda spektrofotometryczna PB-08 wydanie 5 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14537.0001 i nr 1.14763.0001 Woda, Scieki Stezenie azotu ogolnego\nZakres (0,50 - 150) mg/l\nMetoda spektrofotometryczna PB-08 wydanie 5 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14537.0001 i nr 1.14763.0001","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 - 150) mg/l"}],"search_en":"Water, Wastewater Total nitrogen concentration Spectrophotometric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PB-08 wydanie 5 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14537.0001 i nr 1.14763.0001","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 - 150) mg/l"}],"search_zh":"水、污水 总氮浓度 分光光度法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PB-08 wydanie 5 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14537.0001 i nr 1.14763.0001","technique_zh":"分光光度法","test_object_zh":"水、污水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"},{"_id":"6a7d78940636ba417e419f9c","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(6 - 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (6 - 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (6 - 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (6 - 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(6 - 6000) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand Optical method Environmental Laboratory; Bystry 25, 11-500 Giżycko BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Water, Wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(6 - 6000) mg/l O2"}],"search_zh":"水、污水 生化需氧量 光学法 环境实验室；Bystry 25, 11-500 Giżycko BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、污水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"},{"_id":"6a7d78940636ba417e419f9d","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1,0 – 6,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda optyczna","reference":"PN-EN 1899-2:2002 z wyłączeniem pkt. 7.2","norm_bases":["PN-EN 1899-2:2002 z wyłączeniem pkt. 7.2"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wyłączeniem pkt. 7.2 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wylaczeniem pkt. 7.2","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1,0 – 6,0) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand Optical method Environmental Laboratory; Bystry 25, 11-500 Giżycko BOD5 Range PN-EN 1899-2:2002 z wyłączeniem pkt. 7.2","technique_en":"Optical method","test_object_en":"Water, Wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1,0 – 6,0) mg/l O2"}],"search_zh":"水、污水 生化需氧量 光学法 环境实验室；Bystry 25, 11-500 Giżycko BZT5（BOD5） 范围 PN-EN 1899-2:2002 z wyłączeniem pkt. 7.2","technique_zh":"光学法","test_object_zh":"水、污水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"},{"_id":"6a7d78940636ba417e419f9e","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu ChZT-Cr","parameters":[{"name":"Zakres","range":"(6,5 - 10000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (6,5 - 10000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (6,5 - 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Woda do spozycia przez ludzi, Scieki Chemiczne zapotrzebowanie tlenu ChZT-Cr\nZakres (6,5 - 10000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Chemical oxygen demand COD-Cr","parameters_en":[{"name":"Range","range":"(6,5 - 10000) mg/l O2"}],"search_en":"Water, Water intended for human consumption, Wastewater Chemical oxygen demand COD-Cr Spectrophotometric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(6,5 - 10000) mg/l O2"}],"search_zh":"水、生活饮用水、废水 化学需氧量 COD-Cr 分光光度法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko","methodology_zh":"化学需氧量 COD-Cr"},{"_id":"6a7d78940636ba417e419f9f","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 - 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi, Scieki pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 - 10,0"}],"search_en":"Water, Water intended for human consumption, Wastewater pH Potentiometric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 - 10,0"}],"search_zh":"水、生活饮用水、废水 pH 值 电位法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、废水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"},{"_id":"6a7d78940636ba417e419fa0","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie fosforanów","parameters":[{"name":"Zakres","range":"(0,10 - 15,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforanów\nZakres (0,10 - 15,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-13 wydanie 5 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14848.0001","norm_bases":["PB-13 wydanie 5 z dnia 02.01.2026 r.","na podstawie testu kuwetowego Merck nr 1.14848.0001"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki Stężenie fosforanów\nZakres (0,10 - 15,0) mg/l\nMetoda spektrofotometryczna PB-13 wydanie 5 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14848.0001 Woda do spozycia przez ludzi, Scieki Stezenie fosforanow\nZakres (0,10 - 15,0) mg/l\nMetoda spektrofotometryczna PB-13 wydanie 5 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14848.0001","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Phosphate concentration","parameters_en":[{"name":"Range","range":"(0,10 - 15,0) mg/l"}],"search_en":"Water intended for human consumption, Wastewater Phosphate concentration Spectrophotometric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PB-13 wydanie 5 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14848.0001","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 - 15,0) mg/l"}],"search_zh":"生活饮用水、废水 磷酸盐浓度 分光光度法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PB-13 wydanie 5 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14848.0001","technique_zh":"分光光度法","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko","methodology_zh":"磷酸盐浓度","test_object_zh":"生活饮用水、废水"},{"_id":"6a7d78940636ba417e419fa1","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,026 - 157) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,026 - 157) mg/l\nMetoda spektrofotometryczna","reference":"PB-05 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14752.0001","norm_bases":["PB-05 wydanie 6 z dnia 02.01.2026 r.","na podstawie testu kuwetowego Merck nr 1.14752.0001"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki Stężenie azotu amonowego\nZakres (0,026 - 157) mg/l\nMetoda spektrofotometryczna PB-05 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14752.0001 Woda do spozycia przez ludzi, Scieki Stezenie azotu amonowego\nZakres (0,026 - 157) mg/l\nMetoda spektrofotometryczna PB-05 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14752.0001","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,026 - 157) mg/l"}],"search_en":"Water intended for human consumption, Wastewater Ammonium nitrogen concentration Spectrophotometric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PB-05 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14752.0001","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,026 - 157) mg/l"}],"search_zh":"生活饮用水、废水 氨氮浓度 分光光度法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PB-05 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14752.0001","technique_zh":"分光光度法","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko","test_object_zh":"生活饮用水、废水"},{"_id":"6a7d78940636ba417e419fa2","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,033 - 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,033 - 200) mg/l\nMetoda spektrofotometryczna","reference":"PB-05 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14752.0001","norm_bases":["PB-05 wydanie 6 z dnia 02.01.2026 r.","na podstawie testu kuwetowego Merck nr 1.14752.0001"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki Stężenie jonu amonowego\nZakres (0,033 - 200) mg/l\nMetoda spektrofotometryczna PB-05 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14752.0001 Woda do spozycia przez ludzi, Scieki Stezenie jonu amonowego\nZakres (0,033 - 200) mg/l\nMetoda spektrofotometryczna PB-05 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14752.0001","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,033 - 200) mg/l"}],"search_en":"Water intended for human consumption, Wastewater Ammonium ion concentration Spectrophotometric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PB-05 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14752.0001","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,033 - 200) mg/l"}],"search_zh":"生活饮用水、废水 铵离子浓度 分光光度法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PB-05 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14752.0001","technique_zh":"分光光度法","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko","test_object_zh":"生活饮用水、废水"},{"_id":"6a7d78940636ba417e419fa3","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,009 - 0,76) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,009 - 0,76) mg/l\nMetoda spektrofotometryczna","reference":"PB-07 wydanie 7 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14776.0001","norm_bases":["PB-07 wydanie 7 z dnia 02.01.2026 r.","na podstawie testu kuwetowego Merck nr 1.14776.0001"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki Stężenie azotu azotynowego\nZakres (0,009 - 0,76) mg/l\nMetoda spektrofotometryczna PB-07 wydanie 7 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14776.0001 Woda do spozycia przez ludzi, Scieki Stezenie azotu azotynowego\nZakres (0,009 - 0,76) mg/l\nMetoda spektrofotometryczna PB-07 wydanie 7 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14776.0001","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,009 - 0,76) mg/l"}],"search_en":"Water intended for human consumption, Wastewater Nitrite nitrogen concentration Spectrophotometric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PB-07 wydanie 7 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14776.0001","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,009 - 0,76) mg/l"}],"search_zh":"生活饮用水、废水 亚硝态氮浓度 分光光度法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PB-07 wydanie 7 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14776.0001","technique_zh":"分光光度法","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko","test_object_zh":"生活饮用水、废水"},{"_id":"6a7d78940636ba417e419fa4","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,030 – 2,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,030 – 2,5) mg/l\nMetoda spektrofotometryczna","reference":"PB-07 wydanie 7 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14776.0001","norm_bases":["PB-07 wydanie 7 z dnia 02.01.2026 r.","na podstawie testu kuwetowego Merck nr 1.14776.0001"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki Stężenie azotynów\nZakres (0,030 – 2,5) mg/l\nMetoda spektrofotometryczna PB-07 wydanie 7 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14776.0001 Woda do spozycia przez ludzi, Scieki Stezenie azotynow\nZakres (0,030 – 2,5) mg/l\nMetoda spektrofotometryczna PB-07 wydanie 7 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14776.0001","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,030 – 2,5) mg/l"}],"search_en":"Water intended for human consumption, Wastewater Nitrite concentration Spectrophotometric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PB-07 wydanie 7 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14776.0001","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,030 – 2,5) mg/l"}],"search_zh":"生活饮用水、废水 亚硝酸盐浓度 分光光度法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PB-07 wydanie 7 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14776.0001","technique_zh":"分光光度法","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko","test_object_zh":"生活饮用水、废水"},{"_id":"6a7d78940636ba417e419fa5","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,14 - 3,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,14 - 3,00) mg/l\nMetoda spektrofotometryczna","reference":"PB-06 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14556.0001","norm_bases":["PB-06 wydanie 6 z dnia 02.01.2026 r.","na podstawie testu kuwetowego Merck nr 1.14556.0001"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki Stężenie azotu azotanowego\nZakres (0,14 - 3,00) mg/l\nMetoda spektrofotometryczna PB-06 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14556.0001 Woda do spozycia przez ludzi, Scieki Stezenie azotu azotanowego\nZakres (0,14 - 3,00) mg/l\nMetoda spektrofotometryczna PB-06 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14556.0001","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,14 - 3,00) mg/l"}],"search_en":"Water intended for human consumption, Wastewater Nitrate nitrogen concentration Spectrophotometric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PB-06 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14556.0001","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,14 - 3,00) mg/l"}],"search_zh":"生活饮用水、废水 硝态氮浓度 分光光度法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PB-06 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14556.0001","technique_zh":"分光光度法","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko","test_object_zh":"生活饮用水、废水"},{"_id":"6a7d78940636ba417e419fa6","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,6 – 13,3) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,6 – 13,3) mg/l\nMetoda spektrofotometryczna","reference":"PB-06 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14556.0001","norm_bases":["PB-06 wydanie 6 z dnia 02.01.2026 r.","na podstawie testu kuwetowego Merck nr 1.14556.0001"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki Stężenie azotanów\nZakres (0,6 – 13,3) mg/l\nMetoda spektrofotometryczna PB-06 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14556.0001 Woda do spozycia przez ludzi, Scieki Stezenie azotanow\nZakres (0,6 – 13,3) mg/l\nMetoda spektrofotometryczna PB-06 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14556.0001","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,6 – 13,3) mg/l"}],"search_en":"Water intended for human consumption, Wastewater Nitrate concentration Spectrophotometric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PB-06 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14556.0001","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,6 – 13,3) mg/l"}],"search_zh":"生活饮用水、废水 硝酸盐浓度 分光光度法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PB-06 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14556.0001","technique_zh":"分光光度法","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko","test_object_zh":"生活饮用水、废水"},{"_id":"6a7d78940636ba417e419fa7","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(9,0 - 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (9,0 - 250) mg/l\nMetoda spektrofotometryczna","reference":"PB-16 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14548.0001","norm_bases":["PB-16 wydanie 6 z dnia 02.01.2026 r.","na podstawie testu kuwetowego Merck nr 1.14548.0001"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki Stężenie siarczanów\nZakres (9,0 - 250) mg/l\nMetoda spektrofotometryczna PB-16 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14548.0001 Woda do spozycia przez ludzi, Scieki Stezenie siarczanow\nZakres (9,0 - 250) mg/l\nMetoda spektrofotometryczna PB-16 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14548.0001","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(9,0 - 250) mg/l"}],"search_en":"Water intended for human consumption, Wastewater Sulfate concentration Spectrophotometric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PB-16 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14548.0001","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(9,0 - 250) mg/l"}],"search_zh":"生活饮用水、废水 硫酸盐浓度 分光光度法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PB-16 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14548.0001","technique_zh":"分光光度法","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko","test_object_zh":"生活饮用水、废水"},{"_id":"6a7d78940636ba417e419fa8","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(9,0 – 250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chlorków\nZakres (9,0 – 250) mg/l\nMetoda spektrofotometryczna","reference":"PB-10 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14730.0001","norm_bases":["PB-10 wydanie 6 z dnia 02.01.2026 r.","na podstawie testu kuwetowego Merck nr 1.14730.0001"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki Stężenie chlorków\nZakres (9,0 – 250) mg/l\nMetoda spektrofotometryczna PB-10 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14730.0001 Woda do spozycia przez ludzi, Scieki Stezenie chlorkow\nZakres (9,0 – 250) mg/l\nMetoda spektrofotometryczna PB-10 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14730.0001","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(9,0 – 250) mg/l"}],"search_en":"Water intended for human consumption, Wastewater Chloride concentration Spectrophotometric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PB-10 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14730.0001","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(9,0 – 250) mg/l"}],"search_zh":"生活饮用水、废水 氯化物浓度 分光光度法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PB-10 wydanie 6 z dnia 02.01.2026 r. | na podstawie testu kuwetowego Merck nr 1.14730.0001","technique_zh":"分光光度法","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko","test_object_zh":"生活饮用水、废水"},{"_id":"6a7d78940636ba417e419fa9","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 - 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 - 250) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Ścieki Stężenie chlorków\nZakres (5,0 - 250) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi, Scieki Stezenie chlorkow\nZakres (5,0 - 250) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 - 250) mg/l"}],"search_en":"Water intended for human consumption, Wastewater Chloride concentration Titrimetric method Environmental Laboratory; Bystry 25, 11-500 Giżycko Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption, Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 - 250) mg/l"}],"search_zh":"生活饮用水、废水 氯化物浓度 滴定法 环境实验室；Bystry 25, 11-500 Giżycko 范围 PN-ISO 9297:1994","technique_zh":"滴定法","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko","test_object_zh":"生活饮用水、废水"},{"_id":"6a7d78940636ba417e419faa","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing Environmental Laboratory; Bystry 25, 11-500 Giżycko PN-EN ISO 19458:2007","test_object_en":"Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 环境实验室；Bystry 25, 11-500 Giżycko PN-EN ISO 19458:2007","test_object_zh":"生活饮用水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"},{"_id":"6a7d78940636ba417e419fab","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temperaturze 36 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Total viable count at 36 °C","search_en":"Water intended for human consumption Total viable count at 36 °C Plate method (pour plate) Environmental Laboratory; Bystry 25, 11-500 Giżycko PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 36 °C 微生物总数 平板法（倾注培养） 环境实验室；Bystry 25, 11-500 Giżycko PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko","methodology_zh":"36 °C 微生物总数"},{"_id":"6a7d78940636ba417e419fac","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temperaturze 22 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Total viable count at 22 °C","search_en":"Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) Environmental Laboratory; Bystry 25, 11-500 Giżycko PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 22 °C 微生物总数 平板法（倾注培养） 环境实验室；Bystry 25, 11-500 Giżycko PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko","methodology_zh":"22 °C 微生物总数"},{"_id":"6a7d78940636ba417e419fad","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli i Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli i Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli i Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli i Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["microbiology","water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Coliform bacteria and Escherichia coli count","search_en":"Water intended for human consumption Coliform bacteria and Escherichia coli count Membrane filtration method Environmental Laboratory; Bystry 25, 11-500 Giżycko PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 大肠菌群数与大肠埃希氏菌数 膜过滤法 环境实验室；Bystry 25, 11-500 Giżycko PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko","methodology_zh":"大肠菌群数与大肠埃希氏菌数"},{"_id":"6a7d78940636ba417e419fae","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków (paciorkowców kałowych)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków (paciorkowców kałowych)\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków (paciorkowców kałowych)\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow (paciorkowcow kalowych)\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Enterococci (faecal streptococci) count","search_en":"Water intended for human consumption Enterococci (faecal streptococci) count Membrane filtration method Environmental Laboratory; Bystry 25, 11-500 Giżycko PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 肠球菌（粪链球菌）数 膜过滤法 环境实验室；Bystry 25, 11-500 Giżycko PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko","methodology_zh":"肠球菌（粪链球菌）数"},{"_id":"6a7d78940636ba417e419faf","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda Colilert-18","techniques":["Metoda Colilert-18"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda Colilert-18","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda Colilert-18 PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda Colilert-18 PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Most probable number of coliform bacteria","search_en":"Water intended for human consumption Most probable number of coliform bacteria Colilert-18 method Environmental Laboratory; Bystry 25, 11-500 Giżycko PN-EN ISO 9308-2:2014-06","technique_en":"Colilert-18 method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"生活饮用水 大肠菌群最可能数（MPN） 环境实验室；Bystry 25, 11-500 Giżycko PN-EN ISO 9308-2:2014-06","test_object_zh":"生活饮用水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"},{"_id":"6a7d78940636ba417e419fb0","lab_id":"69ad52a3de79e566650fb556","country":"PL","accr_number":"AB 1051","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","parameters":[],"technique":"Metoda Colilert-18","techniques":["Metoda Colilert-18"],"computed":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda Colilert-18","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium Środowiskowe; Bystry 25, 11-500 Giżycko","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda Colilert-18 PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda Colilert-18 PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Environmental Laboratory; Bystry 25, 11-500 Giżycko","methodology_en":"Most probable number, Escherichia coli","search_en":"Water intended for human consumption Most probable number, Escherichia coli Colilert-18 method Environmental Laboratory; Bystry 25, 11-500 Giżycko PN-EN ISO 9308-2:2014-06","technique_en":"Colilert-18 method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） 环境实验室；Bystry 25, 11-500 Giżycko PN-EN ISO 9308-2:2014-06","test_object_zh":"生活饮用水","lab_section_zh":"环境实验室；Bystry 25, 11-500 Giżycko"}],"has_pdf":true}