🇵🇱 MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW i KANALIZACJI PL
Water & wastewater
MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW i KANALIZACJI is a laboratory accredited by PCA under number AB 1045 (Zduńska Wola, Poland). Its accreditation scope covers 27 test methods in the following areas: Water & wastewater. Test objects include: Wastewater, Water intended for human consumption, Water, Water intended for human consumption, Wastewater, Water, Wastewater. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Gravimetric method.
At a glance
- Accreditation number: PCA AB 1045
- Methods in scope: 27
- Types of test objects: 5
- Techniques used: 9
- City: Zduńska Wola, Poland
- Accreditation number
- AB 1045
- Accreditation body
- PCA
- City
- Zduńska Wola, Poland
What this laboratory tests (5)
- Wastewater — 7 methods
- Water intended for human consumption — 7 methods
- Water, Water intended for human consumption, Wastewater — 7 methods
- Water, Wastewater — 4 methods
- Rainwater and snowmelt water — 2 methods
Analytical techniques used (9)
- Spectrophotometric method — 12 methods
- Titrimetric method — 4 methods
- Gravimetric method — 3 methods
- Electrochemical method — 2 methods
- Conductometric method — 1 method
- Manual method — 1 method
- Manual method; Automatic method — 1 method
- Nephelometric method — 1 method
- Potentiometric method — 1 method
Laboratory locations
- Pracownia Fizykochemii — ul. Tymienicka 23, 98-220 Zduńska Wola
Accreditation scope — test methods (27)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Pracownia Fizykochemii | |||||
| 1 | Water, Water intended for human consumption, Wastewater | pH Range 2,0 − 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 2 | Water, Water intended for human consumption, Wastewater | Nitrite nitrogen concentration Range (0,003 − 1,8) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 3 | Water, Water intended for human consumption, Wastewater | Nitrite concentration Range (0,010 − 6,0) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 4 | Water, Water intended for human consumption, Wastewater | Nitrate nitrogen concentration Range (0,23 − 13,5) mg/l |
Spectrophotometric method | PB-03 wydanie 5 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCK 339 | |
| 5 | Water, Water intended for human consumption, Wastewater | Nitrate concentration Range (1 − 60) mg/l |
Spectrophotometric method | PB-03 wydanie 5 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCK 339 | |
| 6 | Water, Water intended for human consumption, Wastewater | Total suspended solids (TSS) Range (2,0 − 5000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 7 | Water, Water intended for human consumption, Wastewater | Biochemical oxygen demand − BOD5 Range (0,3 − 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 8 | Water intended for human consumption | Electrical conductivity Range (100 − 2500) µS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 9 | Water intended for human consumption | Total iron concentration Range (0,020 − 20) mg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 10 | Water intended for human consumption | Manganese concentration Range (0,010 − 1,0) mg/l |
Spectrophotometric method | PB-06 wydanie 7 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCW 032 | |
| 11 | Water intended for human consumption | Chloride concentration Range (5,0 − 400) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 12 | Water intended for human consumption | Turbidity Range (0,10 − 50) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 13 | Water intended for human consumption | Ammonium ion concentration Range (0,06 − 77,0) mg/l |
Spectrophotometric method | PN-EN 7150-1:2002 | |
| 14 | Water intended for human consumption | Chemical oxygen demand − COD-Cr Range (7,0 − 150) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 15 | Rainwater and snowmelt water | Total suspended solids (TSS) Range (2,0 – 500) mg/l |
Gravimetric method | PN-EN 872:2007+Ap.1:2007 | |
| 16 | Wastewater | Biochemical oxygen demand − BOD5 Range (1 − 6000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 17 | Wastewater | Chemical oxygen demand − COD-Cr Range (7,0 − 150) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 18 | Wastewater | Ammonium nitrogen concentration Range (0,05 − 60,0) mg/l |
Spectrophotometric method | PN-EN 7150-1:2002 | |
| 19 | Wastewater | Chloride concentration Range (5,0 – 3000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 20 | Wastewater | Total iron concentration Range (0,020 − 20) mg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 21 | Wastewater | Dissolved solids Range (400 − 10000) mg/l |
Gravimetric method | PN-EN 15216:2022-03 | |
| 22 | Wastewater | Sampling for chemical and physical testing | Manual method; Automatic method | PN-ISO 5667-10:2021-11 | |
| 23 | Rainwater and snowmelt water | Sampling for chemical and physical testing | Manual method | PN-ISO 5667-10:2021-11 | |
| 24 | Water, Wastewater | Kjeldahl nitrogen concentration Range (1,0 − 300) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 25 | Water, Wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 26 | Water, Wastewater | Chemical oxygen demand − COD-Cr Range (30 − 20000) mg/l O2 |
Titrimetric method | PN-ISO 6060:2006 | |
| 27 | Water, Wastewater | Total phosphorus concentration Range (0,050 − 50) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010 | |
Reference standards (20)
PB-03 wydanie 5 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCK 339
PB-06 wydanie 7 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCW 032
PN-73/C-04576/14
PN-EN 15216:2022-03
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 7150-1:2002
PN-EN 872:2007+Ap.1:2007
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 6060:2006
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 9297:1994