{"lab":{"_id":"69ad52a3de79e566650fb54e","accr_number":"AB 1045","country":"PL","accr_body":"PCA","address":"","categories":["water"],"city":"Zduńska Wola","imported_at":"2026-03-08T10:42:43.265Z","methods_count":27,"name":"MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW i KANALIZACJI","parse_status":"parsed","parse_version":0,"pdf_files":["AB_1045.pdf"],"scope_summary":"","search_text":"ab 1045","status":"active","updated_at":"2026-03-08T14:50:13.693Z","valid_from":"","valid_until":"","website":"","parse_date":"2026-08-14T12:18:30.427Z","parse_source":"agent-claude-code","email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%201045,podmiot.html","fields_of_testing":[{"codes":"C/28; C/29","pl":"Badania chemiczne wody, wody do spożycia przez ludzi","en":"Chemical tests of water, drinking water"},{"codes":"C/30/P","pl":"Badania chemiczne i pobieranie próbek ścieków","en":"Chemical tests and sampling of sewage"},{"codes":"N/28; N/29","pl":"Badania właściwości fizycznych wody, wody do spożycia przez ludzi","en":"Tests of physical properties of water, drinking water"},{"codes":"N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek ścieków","en":"Tests of physical properties and sampling of sewage"}],"issue":{"no":"17","date":"06.05.2026"},"map_coord":[51.602862,18.93332],"map_geo":"nominatim-city","lab_locations":[{"name":"Pracownia Fizykochemii","address":"ul. Tymienicka 23, 98-220 Zduńska Wola","city":"Zduńska Wola","postal":"98-220"}],"parsed_at":"2026-08-14T12:18:30.427Z","scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/14/b2dff8b2ff577ceed214ca106afc084c/AB%201045.pdf","has_en":true,"category_counts":{"water":27},"category_scores":{"water":27},"has_zh":true},"methods":[{"_id":"6a7f07961995264369d8e0ae","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 − 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 − 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki pH\nZakres 2,0 − 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi, Scieki pH\nZakres 2,0 − 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 − 12,0"}],"search_en":"Water, Water intended for human consumption, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 − 12,0"}],"search_zh":"水、生活饮用水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a7f07961995264369d8e0af","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,003 − 1,8) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,003 − 1,8) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu azotynowego\nZakres (0,003 − 1,8) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu azotynowego\nZakres (0,003 − 1,8) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,003 − 1,8) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,003 − 1,8) mg/l"}],"search_zh":"水、生活饮用水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a7f07961995264369d8e0b0","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,010 − 6,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,010 − 6,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotynów\nZakres (0,010 − 6,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotynow\nZakres (0,010 − 6,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,010 − 6,0) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,010 − 6,0) mg/l"}],"search_zh":"水、生活饮用水、废水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a7f07961995264369d8e0b1","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,23 − 13,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,23 − 13,5) mg/l\nMetoda spektrofotometryczna","reference":"PB-03 wydanie 5 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCK 339","norm_bases":["PB-03 wydanie 5 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCK 339"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotu azotanowego\nZakres (0,23 − 13,5) mg/l\nMetoda spektrofotometryczna PB-03 wydanie 5 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCK 339 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotu azotanowego\nZakres (0,23 − 13,5) mg/l\nMetoda spektrofotometryczna PB-03 wydanie 5 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCK 339","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,23 − 13,5) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PB-03 wydanie 5 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCK 339","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,23 − 13,5) mg/l"}],"search_zh":"水、生活饮用水、废水 硝态氮浓度 分光光度法 范围 PB-03 wydanie 5 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCK 339","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a7f07961995264369d8e0b2","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(1 − 60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (1 − 60) mg/l\nMetoda spektrofotometryczna","reference":"PB-03 wydanie 5 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCK 339","norm_bases":["PB-03 wydanie 5 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCK 339"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Stężenie azotanów\nZakres (1 − 60) mg/l\nMetoda spektrofotometryczna PB-03 wydanie 5 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCK 339 Woda, Woda do spozycia przez ludzi, Scieki Stezenie azotanow\nZakres (1 − 60) mg/l\nMetoda spektrofotometryczna PB-03 wydanie 5 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCK 339","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(1 − 60) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Nitrate concentration Spectrophotometric method Range PB-03 wydanie 5 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCK 339","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(1 − 60) mg/l"}],"search_zh":"水、生活饮用水、废水 硝酸盐浓度 分光光度法 范围 PB-03 wydanie 5 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCK 339","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a7f07961995264369d8e0b3","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 − 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 − 5000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Zawiesiny ogólne\nZakres (2,0 − 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Woda do spozycia przez ludzi, Scieki Zawiesiny ogolne\nZakres (2,0 − 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 − 5000) mg/l"}],"search_en":"Water, Water intended for human consumption, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 − 5000) mg/l"}],"search_zh":"水、生活饮用水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a7f07961995264369d8e0b4","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu − BZT5","parameters":[{"name":"Zakres","range":"(0,3 − 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (0,3 − 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (0,3 − 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Woda do spozycia przez ludzi, Scieki Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (0,3 − 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand − BOD5","parameters_en":[{"name":"Range","range":"(0,3 − 6,0) mg/l O2"}],"search_en":"Water, Water intended for human consumption, Wastewater Biochemical oxygen demand − BOD5 Electrochemical method Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, Water intended for human consumption, Wastewater","parameters_zh":[{"name":"范围","range":"(0,3 − 6,0) mg/l O2"}],"search_zh":"水、生活饮用水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、生活饮用水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a7f07961995264369d8e0b5","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 − 2500) µS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 − 2500) µS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (100 − 2500) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (100 − 2500) µS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 − 2500) µS/cm"}],"search_en":"Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 − 2500) µS/cm"}],"search_zh":"生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水"},{"_id":"6a7f07961995264369d8e0b6","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,020 − 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,020 − 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,020 − 20) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,020 − 20) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,020 − 20) mg/l"}],"search_en":"Water intended for human consumption Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,020 − 20) mg/l"}],"search_zh":"生活饮用水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7f07961995264369d8e0b7","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,010 − 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,010 − 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-06 wydanie 7 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCW 032","norm_bases":["PB-06 wydanie 7 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCW 032"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,010 − 1,0) mg/l\nMetoda spektrofotometryczna PB-06 wydanie 7 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCW 032 Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,010 − 1,0) mg/l\nMetoda spektrofotometryczna PB-06 wydanie 7 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCW 032","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,010 − 1,0) mg/l"}],"search_en":"Water intended for human consumption Manganese concentration Spectrophotometric method Range PB-06 wydanie 7 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCW 032","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,010 − 1,0) mg/l"}],"search_zh":"生活饮用水 锰浓度 分光光度法 范围 PB-06 wydanie 7 z dnia 04.12.2024 r. na podstawie testu Hach Lange LCW 032","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7f07961995264369d8e0b8","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 − 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 − 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,0 − 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,0 − 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 − 400) mg/l"}],"search_en":"Water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 − 400) mg/l"}],"search_zh":"生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a7f07961995264369d8e0b9","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 − 50) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 − 50) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,10 − 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,10 − 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 − 50) NTU"}],"search_en":"Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 − 50) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a7f07961995264369d8e0ba","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,06 − 77,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,06 − 77,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 7150-1:2002","norm_bases":["PN-EN 7150-1:2002"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,06 − 77,0) mg/l\nMetoda spektrofotometryczna PN-EN 7150-1:2002 Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,06 − 77,0) mg/l\nMetoda spektrofotometryczna PN-EN 7150-1:2002","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,06 − 77,0) mg/l"}],"search_en":"Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-EN 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,06 − 77,0) mg/l"}],"search_zh":"生活饮用水 铵离子浓度 分光光度法 范围 PN-EN 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a7f07961995264369d8e0bb","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr","parameters":[{"name":"Zakres","range":"(7,0 − 150) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (7,0 − 150) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (7,0 − 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda do spozycia przez ludzi Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (7,0 − 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand − COD-Cr","parameters_en":[{"name":"Range","range":"(7,0 − 150) mg/l O2"}],"search_en":"Water intended for human consumption Chemical oxygen demand − COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(7,0 − 150) mg/l O2"}],"search_zh":"生活饮用水 化学需氧量 － COD-Cr 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"生活饮用水","methodology_zh":"化学需氧量 － COD-Cr"},{"_id":"6a7f07961995264369d8e0bc","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Wody opadowe i roztopowe","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 500) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap.1:2007","norm_bases":["PN-EN 872:2007+Ap.1:2007"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe i roztopowe Zawiesiny ogólne\nZakres (2,0 – 500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap.1:2007 Wody opadowe i roztopowe Zawiesiny ogolne\nZakres (2,0 – 500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap.1:2007","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 500) mg/l"}],"search_en":"Rainwater and snowmelt water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap.1:2007","technique_en":"Gravimetric method","test_object_en":"Rainwater and snowmelt water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 500) mg/l"}],"search_zh":"雨水与融雪水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap.1:2007","technique_zh":"重量法","test_object_zh":"雨水与融雪水"},{"_id":"6a7f07961995264369d8e0bd","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu − BZT5","parameters":[{"name":"Zakres","range":"(1 − 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1 − 6000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1 − 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu − BZT5\nZakres (1 − 6000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand − BOD5","parameters_en":[{"name":"Range","range":"(1 − 6000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand − BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(1 − 6000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a7f07961995264369d8e0be","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr","parameters":[{"name":"Zakres","range":"(7,0 − 150) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (7,0 − 150) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (7,0 − 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (7,0 − 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand − COD-Cr","parameters_en":[{"name":"Range","range":"(7,0 − 150) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand − COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(7,0 − 150) mg/l O2"}],"search_zh":"污水 化学需氧量 － COD-Cr 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量 － COD-Cr"},{"_id":"6a7f07961995264369d8e0bf","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,05 − 60,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,05 − 60,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 7150-1:2002","norm_bases":["PN-EN 7150-1:2002"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,05 − 60,0) mg/l\nMetoda spektrofotometryczna PN-EN 7150-1:2002 Scieki Stezenie azotu amonowego\nZakres (0,05 − 60,0) mg/l\nMetoda spektrofotometryczna PN-EN 7150-1:2002","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,05 − 60,0) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-EN 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,05 − 60,0) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 范围 PN-EN 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f07961995264369d8e0c0","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 3000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 3000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chlorków\nZakres (5,0 – 3000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (5,0 – 3000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 3000) mg/l"}],"search_en":"Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 3000) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a7f07961995264369d8e0c1","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,020 − 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,020 − 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie żelaza ogólnego\nZakres (0,020 − 20) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Scieki Stezenie zelaza ogolnego\nZakres (0,020 − 20) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,020 − 20) mg/l"}],"search_en":"Wastewater Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,020 − 20) mg/l"}],"search_zh":"污水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a7f07961995264369d8e0c2","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Ścieki","methodology":"Substancje rozpuszczone","parameters":[{"name":"Zakres","range":"(400 − 10000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone\nZakres (400 − 10000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Substancje rozpuszczone\nZakres (400 − 10000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Scieki Substancje rozpuszczone\nZakres (400 − 10000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved solids","parameters_en":[{"name":"Range","range":"(400 − 10000) mg/l"}],"search_en":"Wastewater Dissolved solids Gravimetric method Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(400 − 10000) mg/l"}],"search_zh":"污水 溶解性固体 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"污水","methodology_zh":"溶解性固体"},{"_id":"6a7f07961995264369d8e0c3","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a7f07961995264369d8e0c4","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Wody opadowe i roztopowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe i roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 Wody opadowe i roztopowe Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Rainwater and snowmelt water Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11","technique_en":"Manual method","test_object_en":"Rainwater and snowmelt water","methodology_zh":"化学与物理检测用样品采集","search_zh":"雨水与融雪水 化学与物理检测用样品采集 手工法 PN-ISO 5667-10:2021-11","technique_zh":"手工法","test_object_zh":"雨水与融雪水"},{"_id":"6a7f07961995264369d8e0c5","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1,0 − 300) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,0 − 300) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (1,0 − 300) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (1,0 − 300) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 − 300) mg/l"}],"search_en":"Water, Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 − 300) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a7f07961995264369d8e0c6","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Woda, Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14","test_object_en":"Water, Wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、污水 总氮浓度（计算值） PN-73/C-04576/14","test_object_zh":"水、污水"},{"_id":"6a7f07961995264369d8e0c7","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr","parameters":[{"name":"Zakres","range":"(30 − 20000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (30 − 20000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (30 − 20000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Woda, Scieki Chemiczne zapotrzebowanie tlenu − ChZT-Cr\nZakres (30 − 20000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand − COD-Cr","parameters_en":[{"name":"Range","range":"(30 − 20000) mg/l O2"}],"search_en":"Water, Wastewater Chemical oxygen demand − COD-Cr Titrimetric method Range PN-ISO 6060:2006","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(30 − 20000) mg/l O2"}],"search_zh":"水、污水 化学需氧量 － COD-Cr 滴定法 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"水、污水","methodology_zh":"化学需氧量 － COD-Cr"},{"_id":"6a7f07961995264369d8e0c8","lab_id":"69ad52a3de79e566650fb54e","country":"PL","accr_number":"AB 1045","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,050 − 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,050 − 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010"],"lab_section":"Pracownia Fizykochemii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,050 − 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,050 − 50) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,050 − 50) mg/l"}],"search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,050 − 50) mg/l"}],"search_zh":"水、污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 p.8 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、污水"}],"has_pdf":true}