OTWOCKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW is a laboratory accredited by PCA under number AB 1034 (Otwock, Poland). Its accreditation scope covers 35 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Wastewater, Water intended for human consumption Wastewater.

At a glance

  • Accreditation number: PCA AB 1034
  • Methods in scope: 35
  • Types of test objects: 3
  • City: Otwock, Poland
Accreditation number
AB 1034
Accreditation body
PCA
Address
I KANALIZACJI Sp. z o.o., LABORATORIUM, ul. Józefa Ignacego Kraszewskiego 1
City
Otwock, Poland

What this laboratory tests (3)

Accreditation scope — test methods (35)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Sampling for chemical and physical testing, including sensory PN-ISO 5667-5:2017-10
2 Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
3 Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
4 Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
5 Water intended for human consumption Enterococci (faecal streptococci) count Membrane filtration method PN-EN ISO 7899-2:2004
6 Water intended for human consumption Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
7 Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
8 Water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10
9 Water intended for human consumption Total iron concentration Range (40,0 - 5000) µg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
10 Water intended for human consumption Total manganese concentration Range: (15 - 5000) µg/l Spectrophotometric method PB-01.00 wydanie 8 z dnia 12.10.2023 na podstawie testu pipetowego Hach Nr LCW 032
11 Water intended for human consumption Free chlorine concentration Range: (0,020 - 2,000) mg/l Spectrophotometric method PB-02.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr LCK 310
12 Water intended for human consumption Colour Range: (5 – 250) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
13 Water intended for human consumption Turbidity Range: (0,20 - 40) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
14 Water intended for human consumption Total hardness Range: (20 - 800) mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999
15 Water intended for human consumption pH Range: 2,0 - 10,0 Potentiometric method PN-EN ISO 10523:2012
16 Water intended for human consumption Electrical conductivity Range: (84,0 - 5000) µS/cm Conductometric method PN-EN 27888:1999
17 Water intended for human consumption Threshold odour number TON Range: 1 Paired, simplified, non-forced choice method PN-EN 1622:2006
18 Water intended for human consumption Threshold flavour number TFN Range: 1 Paired, simplified, non-forced choice method PN-EN 1622:2006
19 Wastewater Sampling for chemical and physical testing Manual and automatic method PN-ISO 5667-10:2021-11
20 Wastewater Total suspended solids Range: (2,0 - 15000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
21 Wastewater Chemical oxygen demand – COD Range: (10 - 50000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005
22 Wastewater Content of substances extractable with petroleum ether (Ether extract) Range: (30 - 3000) mg/l Gravimetric method PB-10.00 wydanie 4 z dnia 10.09.2019
23 Wastewater pH Range: 4,0 - 10,0 Potentiometric method PN-EN ISO 10523:2012
24 Wastewater Electrical conductivity Range: (4,0 - 5000) µS/cm Conductometric method PN-EN 27888:1999
25 Wastewater Ammonium nitrogen concentration Range: (0,030 - 130) mg/l Spectrophotometric method PN-ISO 7150-1:2002
26 Wastewater Total phosphorus concentration Range: (0,070 - 20) mg/l Spectrophotometric method PN-EN ISO 6878:2006+ Ap1:2010 +Ap2:2010
27 Wastewater Total nitrogen concentration Range: (1,00 - 500) mg/l Spectrophotometric method PB-11.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 138, LCK 238, LCK 338
28 Wastewater Total phosphorus concentration Range: (0,010 - 40) mg/l Spectrophotometric method PB-04.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 349, LCK 350
29 Wastewater Biochemical oxygen demand BOD 5 Range: (1 - 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019
30 Wastewater Biochemical oxygen demand BOD 5 Range: (0,8 - 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002
31 Water intended for human consumption Wastewater Nitrite nitrogen concentration Range: (0,002 - 1,00) mg/l Spectrophotometric method PN-EN 26777:1999
32 Water intended for human consumption Wastewater Nitrate nitrogen concentration Range: (0,060 - 35) mg/l Spectrophotometric method PB-06.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 339, LCK 340
33 Water intended for human consumption Wastewater Ammonium nitrogen concentration Range: (0,040 - 400) mg/l Spectrophotometric method PB-05.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 302, LCK 303, LCK 304
34 Water intended for human consumption Wastewater Chloride concentration Range: (5,0 - 400) mg/l Titrimetric method PN-ISO 9297:1994
35 Water intended for human consumption Wastewater Sulphate concentration Range: (20 - 500) mg/l Gravimetric method PN-ISO 9280:2002

Reference standards (30)

PB-01.00 wydanie 8 z dnia 12.10.2023 na podstawie testu pipetowego Hach Nr LCW 032
PB-02.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr LCK 310
PB-04.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 349, LCK 350
PB-05.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 302, LCK 303, LCK 304
PB-06.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 339, LCK 340
PB-10.00 wydanie 4 z dnia 10.09.2019
PB-11.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 138, LCK 238, LCK 338
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 14189:2016-10
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006+ Ap1:2010 +Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994