{"lab":{"_id":"69ad52a3de79e566650fb538","accr_number":"AB 1034","country":"PL","accr_body":"PCA","address":"I KANALIZACJI Sp. z o.o., LABORATORIUM, ul. Józefa Ignacego Kraszewskiego 1","categories":["water","microbiology"],"city":"Otwock","imported_at":"2026-03-08T10:42:43.265Z","methods_count":35,"name":"OTWOCKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1034.pdf"],"scope_summary":"","search_text":"otwockie przedsiębiorstwo wodociągów i kanalizacji sp. z o.o., laboratorium, ul. józefa ignacego kraszewskiego 1 other water microbiology automotive pharma electronics","status":"active","updated_at":"2026-03-08T14:50:12.856Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:12.856Z","parse_date":"2026-07-17T16:19:14.469Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://opwik.com/kontakt/","fields_of_testing":[{"codes":"­ C/29/P, C/30/P","pl":"­ Badania chemiczne i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of drinking water, sewage"},{"codes":"­ N/29/P, N/30/P","pl":"­ Badania właściwości fizycznych i pobieranie próbek wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of drinking water, sewage"},{"codes":"­ K/29/P","pl":"­ Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi","en":"Microbiological tests and sampling of drinking water"},{"codes":"­ Q/29","pl":"­ Badania sensoryczne wody do spożycia przez ludzi","en":"Sensory tests of drinking water"}],"issue":{"no":"21","date":"03.02.2026"},"map_coord":[52.096537,21.236715],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":35,"microbiology":3},"category_scores":{"water":32.24,"microbiology":0.24},"has_zh":true},"methods":[{"_id":"6a5a56029af9f73f3825423b","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych, w tym sensorycznych","methodology_en":"Sampling for chemical and physical testing, including sensory","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych, w tym sensorycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych, w tym sensorycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych, w tym sensorycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for chemical and physical testing, including sensory PN-ISO 5667-5:2017-10","search_zh":"生活饮用水 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f3825423c","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f3825423d","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba bakterii grupy coli Metoda filtracji membranowej","methodology_en":"Coliform bacteria count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli Metoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠菌群计数 膜过滤法","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f3825423e","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba Escherichia coli Metoda filtracji membranowej","methodology_en":"Escherichia coli count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Escherichia coli Metoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数 膜过滤法","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f3825423f","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba enterokoków (paciorkowców kałowych) Metoda filtracji membranowej","methodology_en":"Enterococci (faecal streptococci) count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba enterokoków (paciorkowców kałowych) Metoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków (paciorkowców kałowych) Metoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow (paciorkowcow kalowych) Metoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Enterococci (faecal streptococci) count Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"生活饮用水 肠球菌（粪链球菌）数 膜过滤法 PN-EN ISO 7899-2:2004","test_object_zh":"生活饮用水","methodology_zh":"肠球菌（粪链球菌）数 膜过滤法"},{"_id":"6a5a56029af9f73f38254240","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 36 °C Metoda płytkowa (posiew wgłębny)","methodology_en":"Total viable count at 36 °C Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C Metoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36 °C Metoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36 °C Metoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"生活饮用水 36 °C 微生物总数 平板法（倾注平板） PN-EN ISO 6222:2004","test_object_zh":"生活饮用水","methodology_zh":"36 °C 微生物总数 平板法（倾注平板）"},{"_id":"6a5a56029af9f73f38254241","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 22 °C Metoda płytkowa (posiew wgłębny)","methodology_en":"Total viable count at 22 °C Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C Metoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 °C Metoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 °C Metoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"生活饮用水 22 °C 微生物总数 平板法（倾注平板） PN-EN ISO 6222:2004","test_object_zh":"生活饮用水","methodology_zh":"22 °C 微生物总数 平板法（倾注平板）"},{"_id":"6a5a56029af9f73f38254242","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba Clostridium perfringens (łącznie z przetrwalnikami) Metoda filtracji membranowej","methodology_en":"Clostridium perfringens count (including spores) Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Clostridium perfringens (łącznie z przetrwalnikami) Metoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba Clostridium perfringens (łącznie z przetrwalnikami) Metoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda do spozycia przez ludzi Liczba Clostridium perfringens (lacznie z przetrwalnikami) Metoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","search_zh":"生活饮用水 产气荚膜梭菌数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","test_object_zh":"生活饮用水","methodology_zh":"产气荚膜梭菌数（含芽孢） 膜过滤法"},{"_id":"6a5a56029af9f73f38254243","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie żelaza ogólnego Zakres (40,0 - 5000) µg/l Metoda spektrofotometryczna","methodology_en":"Total iron concentration Range (40,0 - 5000) µg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego Zakres (40,0 - 5000) µg/l Metoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza ogólnego Zakres (40,0 - 5000) µg/l Metoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda do spozycia przez ludzi Stezenie zelaza ogolnego Zakres (40,0 - 5000) µg/l Metoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Total iron concentration Range (40,0 - 5000) µg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06","search_zh":"生活饮用水 PN-ISO 6332:2001+Ap1:2016-06","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f38254244","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie manganu ogólnego Zakres: (15 - 5000) µg/l Metoda spektrofotometryczna","methodology_en":"Total manganese concentration Range: (15 - 5000) µg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie manganu ogólnego Zakres: (15 - 5000) µg/l Metoda spektrofotometryczna","reference":"PB-01.00 wydanie 8 z dnia 12.10.2023 na podstawie testu pipetowego Hach Nr LCW 032","norm_bases":["PB-01.00 wydanie 8 z dnia 12.10.2023 na podstawie testu pipetowego Hach Nr LCW 032"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie manganu ogólnego Zakres: (15 - 5000) µg/l Metoda spektrofotometryczna PB-01.00 wydanie 8 z dnia 12.10.2023 na podstawie testu pipetowego Hach Nr LCW 032 Woda do spozycia przez ludzi Stezenie manganu ogolnego Zakres: (15 - 5000) µg/l Metoda spektrofotometryczna PB-01.00 wydanie 8 z dnia 12.10.2023 na podstawie testu pipetowego Hach Nr LCW 032","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Total manganese concentration Range: (15 - 5000) µg/l Spectrophotometric method PB-01.00 wydanie 8 z dnia 12.10.2023 na podstawie testu pipetowego Hach Nr LCW 032","search_zh":"生活饮用水 PB-01.00 wydanie 8 z dnia 12.10.2023 na podstawie testu pipetowego Hach Nr LCW 032","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f38254245","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie chloru wolnego Zakres: (0,020 - 2,000) mg/l Metoda spektrofotometryczna","methodology_en":"Free chlorine concentration Range: (0,020 - 2,000) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego Zakres: (0,020 - 2,000) mg/l Metoda spektrofotometryczna","reference":"PB-02.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr LCK 310","norm_bases":["PB-02.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr LCK 310"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie chloru wolnego Zakres: (0,020 - 2,000) mg/l Metoda spektrofotometryczna PB-02.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr LCK 310 Woda do spozycia przez ludzi Stezenie chloru wolnego Zakres: (0,020 - 2,000) mg/l Metoda spektrofotometryczna PB-02.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr LCK 310","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Free chlorine concentration Range: (0,020 - 2,000) mg/l Spectrophotometric method PB-02.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr LCK 310","search_zh":"生活饮用水 PB-02.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr LCK 310","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f38254246","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Barwa Zakres: (5 – 250) mg/l Pt Metoda spektrofotometryczna","methodology_en":"Colour Range: (5 – 250) mg/l Pt Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (5 – 250) mg/l Pt Metoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 metoda C +Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Barwa Zakres: (5 – 250) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C +Ap1:2015-06 Woda do spozycia przez ludzi Barwa Zakres: (5 – 250) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Colour Range: (5 – 250) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","search_zh":"生活饮用水 PN-EN ISO 7887:2012 metoda C +Ap1:2015-06","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f38254247","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Mętność Zakres: (0,20 - 40) NTU Metoda nefelometryczna","methodology_en":"Turbidity Range: (0,20 - 40) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,20 - 40) NTU Metoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Mętność Zakres: (0,20 - 40) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc Zakres: (0,20 - 40) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Turbidity Range: (0,20 - 40) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","search_zh":"生活饮用水 PN-EN ISO 7027-1:2016-09","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f38254248","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Twardość ogólna Zakres: (20 - 800) mg/l CaCO 3 Metoda miareczkowa","methodology_en":"Total hardness Range: (20 - 800) mg/l CaCO 3 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Twardość ogólna Zakres: (20 - 800) mg/l CaCO 3 Metoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Twardość ogólna Zakres: (20 - 800) mg/l CaCO 3 Metoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi Twardosc ogolna Zakres: (20 - 800) mg/l CaCO 3 Metoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Total hardness Range: (20 - 800) mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999","search_zh":"生活饮用水 PN-ISO 6059:1999","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f38254249","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"pH Zakres: 2,0 - 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 2,0 - 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 2,0 - 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi pH Zakres: 2,0 - 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH Zakres: 2,0 - 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption pH Range: 2,0 - 10,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"生活饮用水 PN-EN ISO 10523:2012","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f3825424a","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Przewodność elektryczna właściwa Zakres: (84,0 - 5000) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (84,0 - 5000) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (84,0 - 5000) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa Zakres: (84,0 - 5000) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa Zakres: (84,0 - 5000) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Electrical conductivity Range: (84,0 - 5000) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"生活饮用水 PN-EN 27888:1999","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f3825424b","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba progowa zapachu TON Zakres: 1 Metoda parzysta, uproszczona, wyboru niewymuszonego","methodology_en":"Threshold odour number TON Range: 1 Paired, simplified, non-forced choice method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba progowa zapachu TON Zakres: 1 Metoda parzysta, uproszczona, wyboru niewymuszonego","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba progowa zapachu TON Zakres: 1 Metoda parzysta, uproszczona, wyboru niewymuszonego PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa zapachu TON Zakres: 1 Metoda parzysta, uproszczona, wyboru niewymuszonego PN-EN 1622:2006","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Threshold odour number TON Range: 1 Paired, simplified, non-forced choice method PN-EN 1622:2006","search_zh":"生活饮用水 PN-EN 1622:2006","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f3825424c","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba progowa smaku TFN Zakres: 1 Metoda parzysta, uproszczona, wyboru niewymuszonego","methodology_en":"Threshold flavour number TFN Range: 1 Paired, simplified, non-forced choice method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba progowa smaku TFN Zakres: 1 Metoda parzysta, uproszczona, wyboru niewymuszonego","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba progowa smaku TFN Zakres: 1 Metoda parzysta, uproszczona, wyboru niewymuszonego PN-EN 1622:2006 Woda do spozycia przez ludzi Liczba progowa smaku TFN Zakres: 1 Metoda parzysta, uproszczona, wyboru niewymuszonego PN-EN 1622:2006","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Threshold flavour number TFN Range: 1 Paired, simplified, non-forced choice method PN-EN 1622:2006","search_zh":"生活饮用水 PN-EN 1622:2006","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f3825424d","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i automatyczna","methodology_en":"Sampling for chemical and physical testing Manual and automatic method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna i automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method PN-ISO 5667-10:2021-11","search_zh":"污水 用于化学与物理检验的采样 手工与自动法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","methodology_zh":"用于化学与物理检验的采样 手工与自动法"},{"_id":"6a5a56029af9f73f3825424e","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawiesiny ogólne Zakres: (2,0 - 15000) mg/l Metoda wagowa","methodology_en":"Total suspended solids Range: (2,0 - 15000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (2,0 - 15000) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawiesiny ogólne Zakres: (2,0 - 15000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne Zakres: (2,0 - 15000) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total suspended solids Range: (2,0 - 15000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"污水 PN-EN 872:2007+Ap1:2007","test_object_zh":"污水"},{"_id":"6a5a56029af9f73f3825424f","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu – ChZT Zakres: (10 - 50000) mg/l O 2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand – COD Range: (10 - 50000) mg/l O 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu – ChZT Zakres: (10 - 50000) mg/l O 2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu – ChZT Zakres: (10 - 50000) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu – ChZT Zakres: (10 - 50000) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Chemical oxygen demand – COD Range: (10 - 50000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"污水 PN-ISO 15705:2005","test_object_zh":"污水"},{"_id":"6a5a56029af9f73f38254250","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Zawartość substancji ekstrahujących się eterem naftowym (Ekstrakt eterowy) Zakres: (30 - 3000) mg/l Metoda wagowa","methodology_en":"Content of substances extractable with petroleum ether (Ether extract) Range: (30 - 3000) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawartość substancji ekstrahujących się eterem naftowym (Ekstrakt eterowy) Zakres: (30 - 3000) mg/l Metoda wagowa","reference":"PB-10.00 wydanie 4 z dnia 10.09.2019","norm_bases":["PB-10.00 wydanie 4 z dnia 10.09.2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Zawartość substancji ekstrahujących się eterem naftowym (Ekstrakt eterowy) Zakres: (30 - 3000) mg/l Metoda wagowa PB-10.00 wydanie 4 z dnia 10.09.2019 Scieki Zawartosc substancji ekstrahujacych sie eterem naftowym (Ekstrakt eterowy) Zakres: (30 - 3000) mg/l Metoda wagowa PB-10.00 wydanie 4 z dnia 10.09.2019","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Content of substances extractable with petroleum ether (Ether extract) Range: (30 - 3000) mg/l Gravimetric method PB-10.00 wydanie 4 z dnia 10.09.2019","search_zh":"污水 PB-10.00 wydanie 4 z dnia 10.09.2019","test_object_zh":"污水"},{"_id":"6a5a56029af9f73f38254251","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"pH Zakres: 4,0 - 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 4,0 - 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 4,0 - 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki pH Zakres: 4,0 - 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH Zakres: 4,0 - 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater pH Range: 4,0 - 10,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"污水 PN-EN ISO 10523:2012","test_object_zh":"污水"},{"_id":"6a5a56029af9f73f38254252","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Przewodność elektryczna właściwa Zakres: (4,0 - 5000) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (4,0 - 5000) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (4,0 - 5000) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Przewodność elektryczna właściwa Zakres: (4,0 - 5000) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Scieki Przewodnosc elektryczna wlasciwa Zakres: (4,0 - 5000) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Electrical conductivity Range: (4,0 - 5000) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"污水 PN-EN 27888:1999","test_object_zh":"污水"},{"_id":"6a5a56029af9f73f38254253","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,030 - 130) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen concentration Range: (0,030 - 130) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,030 - 130) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu amonowego Zakres: (0,030 - 130) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki Stezenie azotu amonowego Zakres: (0,030 - 130) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Ammonium nitrogen concentration Range: (0,030 - 130) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"污水 PN-ISO 7150-1:2002","test_object_zh":"污水"},{"_id":"6a5a56029af9f73f38254254","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,070 - 20) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,070 - 20) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,070 - 20) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+ Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+ Ap1:2010 +Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego Zakres: (0,070 - 20) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006+ Ap1:2010 +Ap2:2010 Scieki Stezenie fosforu ogolnego Zakres: (0,070 - 20) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006+ Ap1:2010 +Ap2:2010","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total phosphorus concentration Range: (0,070 - 20) mg/l Spectrophotometric method PN-EN ISO 6878:2006+ Ap1:2010 +Ap2:2010","search_zh":"污水 PN-EN ISO 6878:2006+ Ap1:2010 +Ap2:2010","test_object_zh":"污水"},{"_id":"6a5a56029af9f73f38254255","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie azotu ogólnego Zakres: (1,00 - 500) mg/l Metoda spektrofotometryczna","methodology_en":"Total nitrogen concentration Range: (1,00 - 500) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego Zakres: (1,00 - 500) mg/l Metoda spektrofotometryczna","reference":"PB-11.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 138, LCK 238, LCK 338","norm_bases":["PB-11.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 138, LCK 238, LCK 338"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie azotu ogólnego Zakres: (1,00 - 500) mg/l Metoda spektrofotometryczna PB-11.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 138, LCK 238, LCK 338 Scieki Stezenie azotu ogolnego Zakres: (1,00 - 500) mg/l Metoda spektrofotometryczna PB-11.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 138, LCK 238, LCK 338","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total nitrogen concentration Range: (1,00 - 500) mg/l Spectrophotometric method PB-11.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 138, LCK 238, LCK 338","search_zh":"污水 PB-11.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 138, LCK 238, LCK 338","test_object_zh":"污水"},{"_id":"6a5a56029af9f73f38254256","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,010 - 40) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,010 - 40) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,010 - 40) mg/l Metoda spektrofotometryczna","reference":"PB-04.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 349, LCK 350","norm_bases":["PB-04.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 349, LCK 350"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie fosforu ogólnego Zakres: (0,010 - 40) mg/l Metoda spektrofotometryczna PB-04.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 349, LCK 350 Scieki Stezenie fosforu ogolnego Zakres: (0,010 - 40) mg/l Metoda spektrofotometryczna PB-04.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 349, LCK 350","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Total phosphorus concentration Range: (0,010 - 40) mg/l Spectrophotometric method PB-04.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 349, LCK 350","search_zh":"污水 PB-04.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 349, LCK 350","test_object_zh":"污水"},{"_id":"6a5a56029af9f73f38254257","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu  BZT 5 Zakres: (1 - 6000) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand  BOD 5 Range: (1 - 6000) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu  BZT 5 Zakres: (1 - 6000) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019","norm_bases":["PN-EN ISO 5815-1:2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu  BZT 5 Zakres: (1 - 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019 Scieki Biochemiczne zapotrzebowanie tlenu  BZT 5 Zakres: (1 - 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Biochemical oxygen demand  BOD 5 Range: (1 - 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019","search_zh":"污水 PN-EN ISO 5815-1:2019","test_object_zh":"污水"},{"_id":"6a5a56029af9f73f38254258","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu  BZT 5 Zakres: (0,8 - 6,0) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand  BOD 5 Range: (0,8 - 6,0) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu  BZT 5 Zakres: (0,8 - 6,0) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu  BZT 5 Zakres: (0,8 - 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002 Scieki Biochemiczne zapotrzebowanie tlenu  BZT 5 Zakres: (0,8 - 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Biochemical oxygen demand  BOD 5 Range: (0,8 - 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002","search_zh":"污水 PN-EN 1899-2:2002","test_object_zh":"污水"},{"_id":"6a5a56029af9f73f38254259","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi Ścieki","test_object_en":"Water intended for human consumption Wastewater","methodology":"Stężenie azotu azotynowego Zakres: (0,002 - 1,00) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite nitrogen concentration Range: (0,002 - 1,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego Zakres: (0,002 - 1,00) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ścieki Stężenie azotu azotynowego Zakres: (0,002 - 1,00) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi Scieki Stezenie azotu azotynowego Zakres: (0,002 - 1,00) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Wastewater Nitrite nitrogen concentration Range: (0,002 - 1,00) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"生活饮用水 废水 PN-EN 26777:1999","test_object_zh":"生活饮用水 废水"},{"_id":"6a5a56029af9f73f3825425a","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi Ścieki","test_object_en":"Water intended for human consumption Wastewater","methodology":"Stężenie azotu azotanowego Zakres: (0,060 - 35) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate nitrogen concentration Range: (0,060 - 35) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego Zakres: (0,060 - 35) mg/l Metoda spektrofotometryczna","reference":"PB-06.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 339, LCK 340","norm_bases":["PB-06.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 339, LCK 340"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ścieki Stężenie azotu azotanowego Zakres: (0,060 - 35) mg/l Metoda spektrofotometryczna PB-06.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 339, LCK 340 Woda do spozycia przez ludzi Scieki Stezenie azotu azotanowego Zakres: (0,060 - 35) mg/l Metoda spektrofotometryczna PB-06.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 339, LCK 340","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Wastewater Nitrate nitrogen concentration Range: (0,060 - 35) mg/l Spectrophotometric method PB-06.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 339, LCK 340","search_zh":"生活饮用水 废水 PB-06.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 339, LCK 340","test_object_zh":"生活饮用水 废水"},{"_id":"6a5a56029af9f73f3825425b","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi Ścieki","test_object_en":"Water intended for human consumption Wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,040 - 400) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen concentration Range: (0,040 - 400) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,040 - 400) mg/l Metoda spektrofotometryczna","reference":"PB-05.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 302, LCK 303, LCK 304","norm_bases":["PB-05.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 302, LCK 303, LCK 304"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ścieki Stężenie azotu amonowego Zakres: (0,040 - 400) mg/l Metoda spektrofotometryczna PB-05.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 302, LCK 303, LCK 304 Woda do spozycia przez ludzi Scieki Stezenie azotu amonowego Zakres: (0,040 - 400) mg/l Metoda spektrofotometryczna PB-05.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 302, LCK 303, LCK 304","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Wastewater Ammonium nitrogen concentration Range: (0,040 - 400) mg/l Spectrophotometric method PB-05.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 302, LCK 303, LCK 304","search_zh":"生活饮用水 废水 PB-05.00 wydanie 5 z dnia 10.09.2019 - na podstawie testu kuwetowego Hach Nr: LCK 302, LCK 303, LCK 304","test_object_zh":"生活饮用水 废水"},{"_id":"6a5a56029af9f73f3825425c","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi Ścieki","test_object_en":"Water intended for human consumption Wastewater","methodology":"Stężenie chlorków Zakres: (5,0 - 400) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5,0 - 400) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,0 - 400) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ścieki Stężenie chlorków Zakres: (5,0 - 400) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi Scieki Stezenie chlorkow Zakres: (5,0 - 400) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Wastewater Chloride concentration Range: (5,0 - 400) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"生活饮用水 废水 PN-ISO 9297:1994","test_object_zh":"生活饮用水 废水"},{"_id":"6a5a56029af9f73f3825425d","lab_id":"69ad52a3de79e566650fb538","country":"PL","accr_number":"AB 1034","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi Ścieki","test_object_en":"Water intended for human consumption Wastewater","methodology":"Stężenie siarczanów Zakres: (20 - 500) mg/l Metoda wagowa","methodology_en":"Sulphate concentration Range: (20 - 500) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów Zakres: (20 - 500) mg/l Metoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ścieki Stężenie siarczanów Zakres: (20 - 500) mg/l Metoda wagowa PN-ISO 9280:2002 Woda do spozycia przez ludzi Scieki Stezenie siarczanow Zakres: (20 - 500) mg/l Metoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Wastewater Sulphate concentration Range: (20 - 500) mg/l Gravimetric method PN-ISO 9280:2002","search_zh":"生活饮用水 废水 PN-ISO 9280:2002","test_object_zh":"生活饮用水 废水"}],"has_pdf":true}