🇵🇱 WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ PL

PCA AB 1033 • Bydgoszcz, Poland • 34 methods

EnvironmentElectronics & EMCWater & wastewaterAutomotive

WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ is a laboratory accredited by PCA under number AB 1033 (Bydgoszcz, Poland). Its accreditation scope covers 34 test methods in the following areas: Environment, Electronics & EMC, Water & wastewater, Automotive. Test objects include: Water, water intended for human consumption, Water, water intended for human consumption, swimming pool water, Workplace environment - electromagnetic field in the workspace from…, Workplace environment - electromagnetic field in the workspace from….

At a glance

  • Accreditation number: PCA AB 1033
  • Methods in scope: 34
  • Types of test objects: 13
  • City: Bydgoszcz, Poland
Accreditation number
AB 1033
Accreditation body
PCA
Address
W BYDGOSZCZY, ZESPÓŁ LABORATORYJNY, ul. Gdańska 147
City
Bydgoszcz, Poland

What this laboratory tests (13)

Accreditation scope — test methods (34)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment - indoor electric lighting Illuminance Range: (5 – 10 000) lx Direct measurement method PN-83 E 04040.03
2 Workplace environment - indoor electric lighting Lighting uniformity ( calculated)
3 Workplace environment - noise A-weighted equivalent sound level A-weighted maximum sound level Range: (23 – 136) dB C-weighted peak sound level Range: (68 – 140) dB Direct measurement method PN-EN ISO 9612:2011 z wyłączeniem strategii 2 i 3
4 Workplace environment - noise Noise exposure level referred to: - an 8-hour daily working time (calculated)
5 Workplace environment - moderate microclimate Air temperature Range: (10 – 30) °C Blackened globe temperature Range: (10 – 38) °C Air humidity Range: (25 – 75) % Air velocity Range: (0,15 – 0,5) m/s Direct measurement method PN-EN ISO 7730:2006
6 Workplace environment - moderate microclimate PMV index PPD index (calculated)
7 Workplace environment - energy expenditure Air temperature Range: (5 - 35) °C Air flow Range: (10 - 60) dm3/min Direct measurement method PB – 03/LBŚ wydanie 3 z dnia 10.10.2023 r.
8 Workplace environment - energy expenditure Energy expenditure (calculated)
9 Workplace environment - electromagnetic field in the workspace from stationary communication equipment Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (0,5 - 900) V/m - in the frequency range from 3 MHz to 60 GHz Range: (0,8 - 900) V/m Direct measurement method NO-06-A215-2
10 Workplace environment - electromagnetic field in the workspace from stationary communication equipment Magnetic field strength: - in the frequency range from 300 kHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method
11 Workplace environment - electromagnetic field in the workspace from stationary communication equipment Magnetic field strength: - in the frequency range from 0,8 GHz to 60 GHz (calculated)
12 Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (0,5 - 900) V/m - in the frequency range from 3 MHz to 60 GHz Range: (0,8 - 900) V/m Direct measurement method NO-06-A215-2
13 Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment Magnetic field strength: - in the frequency range from 300 kHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method
14 Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment Magnetic field strength: - in the frequency range from 0,8 GHz to 60 GHz (calculated)
15 Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Electric field strength: - in the frequency range from 1,6 MHz to 3 GHz Range: (0,5 - 900) V/m Direct measurement method NO-06-A215-2
16 Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Magnetic field strength: - in the frequency range from 1,6 MHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method
17 Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Magnetic field strength: - in the frequency range from 0,8 GHz to 3 GHz (calculated)
18 Workplace environment - electromagnetic field in the workspace from measurement and control apparatus Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (0,5 - 900) V/m - in the frequency range from 3 MHz to 60 GHz Range: (0,8 - 900) V/m Direct measurement method NO-06-A215-2
19 Workplace environment - electromagnetic field in the workspace from measurement and control apparatus Magnetic field strength: - in the frequency range from 300 kHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method
20 Workplace environment - electromagnetic field in the workspace from measurement and control apparatus Magnetic field strength: - in the frequency range from 0,8 GHz to 60 GHz (calculated)
21 Canned products in tin packaging - fruit, vegetable and vegetable-meat preserves Leak tightness of the packaging Vacuum method PN-A-75052-2:1990 z wyłączeniem pkt. 2.2.3 i pkt. 2.2.4
22 Canned products in tin packaging - fruit, vegetable and vegetable-meat preserves Durability Incubation test method PN-A-75052-3:1990
23 Canned products in tin packaging - fish products Leak tightness of the packaging Vacuum method PN-A-86732:1992 pkt.2.3.10
24 Canned products in tin packaging - fish products Durability Incubation test method PN-A-86732:1992 pkt. 2.3.11
25 Canned products in metal packaging - meat and meat products Leak tightness of the packaging Vacuum method PN-A-82055-4:1997 z wyłączeniem pkt. 2.4.1.3
26 Canned products in metal packaging - meat and meat products Durability Incubation test method PN-A-82055-5:1994
27 Water, water intended for human consumption, swimming pool water Total count of microorganisms at 360C Plate method (pour plate) PN-EN ISO 6222:2004
28 Water, water intended for human consumption, swimming pool water Total count of microorganisms at 220C Plate method (pour plate)
29 Water, water intended for human consumption Electrical conductivity Range: (20 – 2000)μS/cm Conductometric method PN-EN 27888:1999
30 Water, water intended for human consumption Nitrite concentration Range: (0,005 - 0,120)mg/l Spectrophotometric method PN-EN 26777:1999
31 Water, water intended for human consumption True colour Range: (2 – 100) mg/l Pt Spectrophotometric method PN-EN ISO 7887: 2012 + Ap1:2015-06
32 Water, water intended for human consumption Ammonium ion concentration Range: (0,05 – 2,50) mg/l Spectrophotometric method PN-ISO 7150-1:2002
33 Water, water intended for human consumption, swimming pool water Total iron concentration Range: (0,010 – 4,0) mg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
34 Water, water intended for human consumption, swimming pool water pH Range: 4,0 – 10,0 Potentiometric method PN-EN ISO 10523:2012

Reference standards (18)

NO-06-A215-2
PB – 03/LBŚ wydanie 3 z dnia 10.10.2023 r.
PN-83 E 04040.03
PN-A-75052-2:1990 z wyłączeniem pkt. 2.2.3 i pkt. 2.2.4
PN-A-75052-3:1990
PN-A-82055-4:1997 z wyłączeniem pkt. 2.4.1.3
PN-A-82055-5:1994
PN-A-86732:1992 pkt. 2.3.11
PN-A-86732:1992 pkt.2.3.10
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 6222:2004
PN-EN ISO 7730:2006
PN-EN ISO 7887: 2012 + Ap1:2015-06
PN-EN ISO 9612:2011 z wyłączeniem strategii 2 i 3
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002