🇵🇱 WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ PL
EnvironmentElectronics & EMCWater & wastewaterAutomotive
WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ is a laboratory accredited by PCA under number AB 1033 (Bydgoszcz, Poland). Its accreditation scope covers 34 test methods in the following areas: Environment, Electronics & EMC, Water & wastewater, Automotive. Test objects include: Water, water intended for human consumption, Water, water intended for human consumption, swimming pool water, Workplace environment - electromagnetic field in the workspace from…, Workplace environment - electromagnetic field in the workspace from….
At a glance
- Accreditation number: PCA AB 1033
- Methods in scope: 34
- Types of test objects: 13
- City: Bydgoszcz, Poland
- Accreditation number
- AB 1033
- Accreditation body
- PCA
- Address
- W BYDGOSZCZY, ZESPÓŁ LABORATORYJNY, ul. Gdańska 147
- City
- Bydgoszcz, Poland
What this laboratory tests (13)
- Water, water intended for human consumption — 4 methods
- Water, water intended for human consumption, swimming pool water — 4 methods
- Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment — 3 methods
- Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices — 3 methods
- Workplace environment - electromagnetic field in the workspace from measurement and control apparatus — 3 methods
- Workplace environment - electromagnetic field in the workspace from stationary communication equipment — 3 methods
- Canned products in metal packaging - meat and meat products — 2 methods
- Canned products in tin packaging - fish products — 2 methods
- Canned products in tin packaging - fruit, vegetable and vegetable-meat preserves — 2 methods
- Workplace environment - energy expenditure — 2 methods
- Workplace environment - indoor electric lighting — 2 methods
- Workplace environment - moderate microclimate — 2 methods
- Workplace environment - noise — 2 methods
Accreditation scope — test methods (34)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Workplace environment - indoor electric lighting | Illuminance Range: (5 – 10 000) lx Direct measurement method | PN-83 E 04040.03 | ||
| 2 | Workplace environment - indoor electric lighting | Lighting uniformity ( calculated) | |||
| 3 | Workplace environment - noise | A-weighted equivalent sound level A-weighted maximum sound level Range: (23 – 136) dB C-weighted peak sound level Range: (68 – 140) dB Direct measurement method | PN-EN ISO 9612:2011 z wyłączeniem strategii 2 i 3 | ||
| 4 | Workplace environment - noise | Noise exposure level referred to: - an 8-hour daily working time (calculated) | |||
| 5 | Workplace environment - moderate microclimate | Air temperature Range: (10 – 30) °C Blackened globe temperature Range: (10 – 38) °C Air humidity Range: (25 – 75) % Air velocity Range: (0,15 – 0,5) m/s Direct measurement method | PN-EN ISO 7730:2006 | ||
| 6 | Workplace environment - moderate microclimate | PMV index PPD index (calculated) | |||
| 7 | Workplace environment - energy expenditure | Air temperature Range: (5 - 35) °C Air flow Range: (10 - 60) dm3/min Direct measurement method | PB – 03/LBŚ wydanie 3 z dnia 10.10.2023 r. | ||
| 8 | Workplace environment - energy expenditure | Energy expenditure (calculated) | |||
| 9 | Workplace environment - electromagnetic field in the workspace from stationary communication equipment | Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (0,5 - 900) V/m - in the frequency range from 3 MHz to 60 GHz Range: (0,8 - 900) V/m Direct measurement method | NO-06-A215-2 | ||
| 10 | Workplace environment - electromagnetic field in the workspace from stationary communication equipment | Magnetic field strength: - in the frequency range from 300 kHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method | |||
| 11 | Workplace environment - electromagnetic field in the workspace from stationary communication equipment | Magnetic field strength: - in the frequency range from 0,8 GHz to 60 GHz (calculated) | |||
| 12 | Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment | Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (0,5 - 900) V/m - in the frequency range from 3 MHz to 60 GHz Range: (0,8 - 900) V/m Direct measurement method | NO-06-A215-2 | ||
| 13 | Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment | Magnetic field strength: - in the frequency range from 300 kHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method | |||
| 14 | Workplace environment - electromagnetic field in the workspace from - mobile communication devices - vehicles with communication equipment | Magnetic field strength: - in the frequency range from 0,8 GHz to 60 GHz (calculated) | |||
| 15 | Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices | Electric field strength: - in the frequency range from 1,6 MHz to 3 GHz Range: (0,5 - 900) V/m Direct measurement method | NO-06-A215-2 | ||
| 16 | Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices | Magnetic field strength: - in the frequency range from 1,6 MHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method | |||
| 17 | Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices | Magnetic field strength: - in the frequency range from 0,8 GHz to 3 GHz (calculated) | |||
| 18 | Workplace environment - electromagnetic field in the workspace from measurement and control apparatus | Electric field strength: - in the frequency range from 100 kHz to 6 GHz Range: (0,5 - 900) V/m - in the frequency range from 3 MHz to 60 GHz Range: (0,8 - 900) V/m Direct measurement method | NO-06-A215-2 | ||
| 19 | Workplace environment - electromagnetic field in the workspace from measurement and control apparatus | Magnetic field strength: - in the frequency range from 300 kHz to 1 GHz Range: (0,017 - 16) A/m Direct measurement method | |||
| 20 | Workplace environment - electromagnetic field in the workspace from measurement and control apparatus | Magnetic field strength: - in the frequency range from 0,8 GHz to 60 GHz (calculated) | |||
| 21 | Canned products in tin packaging - fruit, vegetable and vegetable-meat preserves | Leak tightness of the packaging Vacuum method | PN-A-75052-2:1990 z wyłączeniem pkt. 2.2.3 i pkt. 2.2.4 | ||
| 22 | Canned products in tin packaging - fruit, vegetable and vegetable-meat preserves | Durability Incubation test method | PN-A-75052-3:1990 | ||
| 23 | Canned products in tin packaging - fish products | Leak tightness of the packaging Vacuum method | PN-A-86732:1992 pkt.2.3.10 | ||
| 24 | Canned products in tin packaging - fish products | Durability Incubation test method | PN-A-86732:1992 pkt. 2.3.11 | ||
| 25 | Canned products in metal packaging - meat and meat products | Leak tightness of the packaging Vacuum method | PN-A-82055-4:1997 z wyłączeniem pkt. 2.4.1.3 | ||
| 26 | Canned products in metal packaging - meat and meat products | Durability Incubation test method | PN-A-82055-5:1994 | ||
| 27 | Water, water intended for human consumption, swimming pool water | Total count of microorganisms at 360C Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 28 | Water, water intended for human consumption, swimming pool water | Total count of microorganisms at 220C Plate method (pour plate) | |||
| 29 | Water, water intended for human consumption | Electrical conductivity Range: (20 – 2000)μS/cm Conductometric method | PN-EN 27888:1999 | ||
| 30 | Water, water intended for human consumption | Nitrite concentration Range: (0,005 - 0,120)mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 31 | Water, water intended for human consumption | True colour Range: (2 – 100) mg/l Pt Spectrophotometric method | PN-EN ISO 7887: 2012 + Ap1:2015-06 | ||
| 32 | Water, water intended for human consumption | Ammonium ion concentration Range: (0,05 – 2,50) mg/l Spectrophotometric method | PN-ISO 7150-1:2002 | ||
| 33 | Water, water intended for human consumption, swimming pool water | Total iron concentration Range: (0,010 – 4,0) mg/l Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | ||
| 34 | Water, water intended for human consumption, swimming pool water | pH Range: 4,0 – 10,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
Reference standards (18)
NO-06-A215-2
PB – 03/LBŚ wydanie 3 z dnia 10.10.2023 r.
PN-83 E 04040.03
PN-A-75052-2:1990 z wyłączeniem pkt. 2.2.3 i pkt. 2.2.4
PN-A-75052-3:1990
PN-A-82055-4:1997 z wyłączeniem pkt. 2.4.1.3
PN-A-82055-5:1994
PN-A-86732:1992 pkt. 2.3.11
PN-A-86732:1992 pkt.2.3.10
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 6222:2004
PN-EN ISO 7730:2006
PN-EN ISO 7887: 2012 + Ap1:2015-06
PN-EN ISO 9612:2011 z wyłączeniem strategii 2 i 3
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002