Environment
OPA-ROW SP. Z O.O. is a laboratory accredited by PCA under number AB 1028 (Rybnik, Poland). Its accreditation scope covers 46 test methods in the following areas: Environment. Test objects include: Waste gases, Workplace environment and general environment – outdoor electric li…, Workplace environment and rooms in buildings – emergency electric l…, Waste gas dedusting equipment.
At a glance
- Accreditation number: PCA AB 1028
- Methods in scope: 46
- Types of test objects: 7
- City: Rybnik, Poland
- Accreditation number
- AB 1028
- Accreditation body
- PCA
- Address
- LABORATORIUM BADAŃ ŚRODOWISKOWYCH, ul. Rymera 40 c, 44-270 Rybnik
- City
- Rybnik, Poland
What this laboratory tests (7)
- Waste gases — 32 methods
- Workplace environment and general environment – outdoor electric lighting — 3 methods
- Workplace environment and rooms in buildings – emergency electric lighting — 3 methods
- Waste gas dedusting equipment — 2 methods
- Workplace environment – electric lighting of surface areas of underground mining plants — 2 methods
- Workplace environment – electric lighting of underground workings of mining plants — 2 methods
- Workplace environment and rooms in buildings – indoor electric lighting — 2 methods
Accreditation scope — test methods (46)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Waste gases | Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method | PN-Z-04030-7:1994 | ||
| 2 | Waste gases | Sampling for determination of dust concentration | |||
| 3 | Waste gases | Dust concentration Range: (0,001 – 40) g/m3 Gravimetric method | |||
| 4 | Waste gases | Dust emission (calculated) | |||
| 5 | Waste gases | Sampling for determination of dust concentration | PN-EN 13284-1:2018-02 | ||
| 6 | Waste gases | Dust concentration Range: (0,001 – 0,05) g/m3 Gravimetric method | |||
| 7 | Waste gases | Concentration of oxygen, carbon monoxide, nitrogen monoxide, nitrogen oxides, nitrogen dioxide, sulphur dioxide, carbon dioxide, Range: - O (3,0 – 21) % 2 Electrochemical method Paramagnetic method (PMD) - CO (6,0 – 1250) mg/m3 - NO (4,0 – 600) mg/m3 - NO (8,0 – 110) mg/m3 2 - SO (9,0 – 1200) mg/m3 2 - CO (0,5 – 15) % 2 Non-dispersive infrared spectrometry method (NDIR) - NO (4,0 – 2050) mg/m3 x Chemiluminescence method (CLD) | PN-ISO 10396:2001 | ||
| 8 | Waste gases | Emission of CO, NO and NO , NO (NO and NO 2 x 2 calculated as NO 2), SO 2, CO 2 (calculated) | |||
| 9 | Waste gases | Sampling for determination of organic compounds Method using activated carbon/silica gel/absorbing solutions | PN-Z-04008-4:1999 | ||
| 10 | Waste gases | Emission of organic compounds (calculated) | |||
| 11 | Waste gases | Sampling for the determination of hydrogen chloride | PN-EN-1911:2011 | ||
| 12 | Waste gases | Hydrogen chloride emission (calculated) | |||
| 13 | Waste gases | Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V | PN-EN 14385:2005 | ||
| 14 | Waste gases | Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated) | |||
| 15 | Waste gases | Sampling for determination of total mercury concentration | PN-EN 13211+AC:2006 | ||
| 16 | Waste gases | Total mercury emission (calculated) | |||
| 17 | Waste gases | Sampling for determination of HF concentration | ISO 15713:2006 CEN/TS 17340:2020-09 | ||
| 18 | Waste gases | HF emission (calculated) | |||
| 19 | Waste gases | O 2 concentration Range: (1,0 - 21,0) % Paramagnetic method (PMD) | PN-EN 14789:2017-04 | ||
| 20 | Waste gases | CO 2 concentration Range: (1,0 – 21,0) % Non-dispersive infrared spectrometry method (NDIR) | ISO 12039:2019 CEN/TS 17405:2020 | ||
| 21 | Waste gases | CO 2 emission (calculated) | |||
| 22 | Waste gases | CO concentration Range: (4,0 – 900) mg/m3 Non-dispersive infrared spectrometry method (NDIR) | PN-EN 15058:2017-04 | ||
| 23 | Waste gases | CO emission (calculated) | |||
| 24 | Waste gases | NOx concentration (NO and NO calculated as 2 NO ) 2 Range: NOx (4,0 – 1400) mg/m3 Chemiluminescence method (CLD) | PN-N 14792:2017-04 | ||
| 25 | Waste gases | Emission of NOx (NO and NO calculated as NO ) 2 2 (calculated) | |||
| 26 | Waste gases | Concentration of oxygen, carbon monoxide, nitrogen dioxide, nitrogen monoxide, sulphur dioxide Range: - O (3,0 – 21) % 2 - CO (6,0 – 1250) mg/m3 - NO (8,0 – 110) mg/m3 2 - NO (4,0 – 600) mg/m3 - SO (9,0 – 1200) mg/m3 2 Electrochemical method | PN-ISO 10396:2001 | ||
| 27 | Waste gases | Dust sampling for determination of the concentration of Sn , Zn, Fe | PN-EN 14385:2005 | ||
| 28 | Waste gases | Emission of Sn , Zn, Fe (calculated) | |||
| 29 | Waste gases | Dust sampling for particle size analysis | PN-Z-04030-7:1994 | ||
| 30 | Waste gases | PM10, PM2,5 dust emission (calculated) | |||
| 31 | Waste gases | Sampling for determination of ammonia concentration (NH) 3 | P/PLBŚ/10 wyd. I z dnia 09.07.2018r PN-EN ISO 21877:2020-03 | ||
| 32 | Waste gases | Emission of ammonia (NH ) (calculated) 3 | |||
| 33 | Waste gas dedusting equipment | Dust concentration Range: (0,001 – 40) g/m3 Gravimetric method | PN-87/M-34129:1987 – metoda A PN-Z-04030-7:1994 PN-EN 13284-1:2018-02 | ||
| 34 | Waste gas dedusting equipment | Dust removal efficiency (calculated) | |||
| 35 | Workplace environment – electric lighting of underground workings of mining plants | Illuminance Range: (0,5 – 3000) Ix Direct measurement method | PN-83/E-04040.03 PN-G-02600:1996 | ||
| 36 | Workplace environment – electric lighting of underground workings of mining plants | Illuminance uniformity (calculated) | |||
| 37 | Workplace environment – electric lighting of surface areas of underground mining plants | Illuminance Range: (0,5 – 10000) Ix Direct measurement method | PN-83/E-04040.03 PN-G-02601:1999 | ||
| 38 | Workplace environment – electric lighting of surface areas of underground mining plants | Illuminance uniformity (calculated) | |||
| 39 | Workplace environment and rooms in buildings – indoor electric lighting | Illuminance Range: (0,5 – 10000) Ix Direct measurement method | PN-83/E-04040.03 | ||
| 40 | Workplace environment and rooms in buildings – indoor electric lighting | Illuminance uniformity (calculated) | |||
| 41 | Workplace environment and general environment – outdoor electric lighting | Illuminance Range: (0,5 – 10000) Ix Direct measurement method | PN-83/E-04040.03 PN-EN 12464-2:2014-05 | ||
| 42 | Workplace environment and general environment – outdoor electric lighting | Illuminance uniformity (calculated) | |||
| 43 | Workplace environment and general environment – outdoor electric lighting | Illumination variation (calculated) | |||
| 44 | Workplace environment and rooms in buildings – emergency electric lighting | Illuminance Range: (0,5 – 200) Ix Direct measurement method | PN-EN 1838:2013-11 z wyłączeniem pkt. 5 | ||
| 45 | Workplace environment and rooms in buildings – emergency electric lighting | Ratio of minimum to maximum illuminance (calculated) | |||
| 46 | Workplace environment and rooms in buildings – emergency electric lighting | Illuminance uniformity for the high-risk zone (calculated) | |||
Reference standards (19)
ISO 12039:2019 CEN/TS 17405:2020
ISO 15713:2006 CEN/TS 17340:2020-09
P/PLBŚ/10 wyd. I z dnia 09.07.2018r PN-EN ISO 21877:2020-03
PN-83/E-04040.03
PN-83/E-04040.03 PN-EN 12464-2:2014-05
PN-83/E-04040.03 PN-G-02600:1996
PN-83/E-04040.03 PN-G-02601:1999
PN-87/M-34129:1987 – metoda A PN-Z-04030-7:1994 PN-EN 13284-1:2018-02
PN-EN 13211+AC:2006
PN-EN 13284-1:2018-02
PN-EN 14385:2005
PN-EN 14789:2017-04
PN-EN 15058:2017-04
PN-EN 1838:2013-11 z wyłączeniem pkt. 5
PN-EN-1911:2011
PN-ISO 10396:2001
PN-N 14792:2017-04
PN-Z-04008-4:1999
PN-Z-04030-7:1994