{"lab":{"_id":"69ad52a3de79e566650fb52e","accr_number":"AB 1028","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAŃ ŚRODOWISKOWYCH, ul. Rymera 40 c, 44-270 Rybnik","categories":["environment"],"city":"Rybnik","imported_at":"2026-03-08T10:42:43.265Z","methods_count":46,"name":"OPA-ROW SP. Z O.O.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1028.pdf"],"scope_summary":"","search_text":"opa-row sp. z o.o. laboratorium badań środowiskowych, ul. rymera 40 c, 44-270 rybnik other environment materials pharma electronics metrology","status":"active","updated_at":"2026-03-08T14:50:12.252Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:12.252Z","parse_date":"2026-07-17T16:19:14.086Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://opa-row.pl/","fields_of_testing":[{"codes":"C/36/P","pl":"Badania chemiczne i pobieranie próbek gazów odlotowych","en":"Chemical tests and sampling of waste gases"},{"codes":"G/33, 34, 35","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki uciążliwe – oświetlenie), środowisko ogólne (czynniki fizyczne – oświetlenie), pomieszczenia (warunki środowiskowe) – oświetlenie","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (nuisance factors – lighting), general environment (physical factors –lighting), rooms (environmental condotions) - lighting"},{"codes":"G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – gazy (gazy odlotowe)","en":"Tests concerning environmental engineering (environmental and climatic) – gases (waste gases)"},{"codes":"","pl":"Badania inne – urządzenia ochrony powietrza","en":"Other tests – air protection equipment"},{"codes":"M/39","pl":"Badania właściwości fizycznych i pobieranie próbek gazów odlotowych","en":"Tests of physical properties and sampling of waste gases"},{"codes":"N/36/P","pl":"Pobieranie próbek gazów odlotowych","en":"Sampling of waste gases"}],"issue":{"no":"18","date":"17.02.2026"},"map_coord":[50.060424,18.49596],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":25,"other":20,"materials":2},"category_scores":{"environment":13.3,"other":8.51,"materials":0.09},"has_zh":true},"methods":[{"_id":"6a5a56029af9f73f382540d6","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa Metoda spiętrzenia PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa Metoda spietrzenia PN-Z-04030-7:1994","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Pitot tube method PN-Z-04030-7:1994","search_zh":"废气 动压 > 10 Pa 时的气体体积流量 皮托管法 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"动压 > 10 Pa 时的气体体积流量 皮托管法"},{"_id":"6a5a56029af9f73f382540d7","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of dust concentration","search_zh":"废气 粉尘浓度测定采样","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5a56029af9f73f382540d8","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu Zakres: (0,001 – 40) g/m3 Metoda grawimetryczna","methodology_en":"Dust concentration Range: (0,001 – 40) g/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu Zakres: (0,001 – 40) g/m3 Metoda grawimetryczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu Zakres: (0,001 – 40) g/m3 Metoda grawimetryczna Gazy odlotowe Stezenie pylu Zakres: (0,001 – 40) g/m3 Metoda grawimetryczna","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust concentration Range: (0,001 – 40) g/m3 Gravimetric method","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a56029af9f73f382540d9","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu (z obliczeń)","methodology_en":"Dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) Gazy odlotowe Emisja pylu (z obliczen)","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust emission (calculated)","search_zh":"废气 粉尘排放量（计算值）","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）"},{"_id":"6a5a56029af9f73f382540da","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia pyłu","methodology_en":"Sampling for determination of dust concentration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia pyłu","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia pyłu PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek do oznaczania stezenia pylu PN-EN 13284-1:2018-02","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of dust concentration PN-EN 13284-1:2018-02","search_zh":"废气 粉尘浓度测定采样 PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘浓度测定采样"},{"_id":"6a5a56029af9f73f382540db","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie pyłu Zakres: (0,001 – 0,05) g/m3 Metoda grawimetryczna","methodology_en":"Dust concentration Range: (0,001 – 0,05) g/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu Zakres: (0,001 – 0,05) g/m3 Metoda grawimetryczna","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie pyłu Zakres: (0,001 – 0,05) g/m3 Metoda grawimetryczna Gazy odlotowe Stezenie pylu Zakres: (0,001 – 0,05) g/m3 Metoda grawimetryczna","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust concentration Range: (0,001 – 0,05) g/m3 Gravimetric method","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a56029af9f73f382540dc","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenu, tlenku węgla, tlenku azotu, tlenków azotu, dwutlenku azotu, dwutlenku siarki, dwutlenku węgla, Zakres: - O (3,0 – 21) % 2 Metoda elektrochemiczna Metoda paramagnetyczna (PMD) - CO (6,0 – 1250) mg/m3 - NO (4,0 – 600) mg/m3 - NO (8,0 – 110) mg/m3 2 - SO (9,0 – 1200) mg/m3 2 - CO (0,5 – 15) % 2 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) - NO (4,0 – 2050) mg/m3 x Metoda chemiluminescencyjna (CLD)","methodology_en":"Concentration of oxygen, carbon monoxide, nitrogen monoxide, nitrogen oxides, nitrogen dioxide, sulphur dioxide, carbon dioxide, Range: - O (3,0 – 21) % 2 Electrochemical method Paramagnetic method (PMD) - CO (6,0 – 1250) mg/m3 - NO (4,0 – 600) mg/m3 - NO (8,0 – 110) mg/m3 2 - SO (9,0 – 1200) mg/m3 2 - CO (0,5 – 15) % 2 Non-dispersive infrared spectrometry method (NDIR) - NO (4,0 – 2050) mg/m3 x Chemiluminescence method (CLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu, tlenku węgla, tlenku azotu, tlenków azotu, dwutlenku azotu, dwutlenku siarki, dwutlenku węgla, Zakres: - O (3,0 – 21) % 2 Metoda elektrochemiczna Metoda paramagnetyczna (PMD) - CO (6,0 – 1250) mg/m3 - NO (4,0 – 600) mg/m3 - NO (8,0 – 110) mg/m3 2 - SO (9,0 – 1200) mg/m3 2 - CO (0,5 – 15) % 2 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) - NO (4,0 – 2050) mg/m3 x Metoda chemiluminescencyjna (CLD)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenu, tlenku węgla, tlenku azotu, tlenków azotu, dwutlenku azotu, dwutlenku siarki, dwutlenku węgla, Zakres: - O (3,0 – 21) % 2 Metoda elektrochemiczna Metoda paramagnetyczna (PMD) - CO (6,0 – 1250) mg/m3 - NO (4,0 – 600) mg/m3 - NO (8,0 – 110) mg/m3 2 - SO (9,0 – 1200) mg/m3 2 - CO (0,5 – 15) % 2 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) - NO (4,0 – 2050) mg/m3 x Metoda chemiluminescencyjna (CLD) PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenu, tlenku wegla, tlenku azotu, tlenkow azotu, dwutlenku azotu, dwutlenku siarki, dwutlenku wegla, Zakres: - O (3,0 – 21) % 2 Metoda elektrochemiczna Metoda paramagnetyczna (PMD) - CO (6,0 – 1250) mg/m3 - NO (4,0 – 600) mg/m3 - NO (8,0 – 110) mg/m3 2 - SO (9,0 – 1200) mg/m3 2 - CO (0,5 – 15) % 2 Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) - NO (4,0 – 2050) mg/m3 x Metoda chemiluminescencyjna (CLD) PN-ISO 10396:2001","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Concentration of oxygen, carbon monoxide, nitrogen monoxide, nitrogen oxides, nitrogen dioxide, sulphur dioxide, carbon dioxide, Range: - O (3,0 – 21) % 2 Electrochemical method Paramagnetic method (PMD) - CO (6,0 – 1250) mg/m3 - NO (4,0 – 600) mg/m3 - NO (8,0 – 110) mg/m3 2 - SO (9,0 – 1200) mg/m3 2 - CO (0,5 – 15) % 2 Non-dispersive infrared spectrometry method (NDIR) - NO (4,0 – 2050) mg/m3 x Chemiluminescence method (CLD) PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5a56029af9f73f382540dd","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja CO, NO i NO , NO (NO i NO 2 x 2 w przeliczeniu na NO 2), SO 2, CO 2 (z obliczeń)","methodology_en":"Emission of CO, NO and NO , NO (NO and NO 2 x 2 calculated as NO 2), SO 2, CO 2 (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CO, NO i NO , NO (NO i NO 2 x 2 w przeliczeniu na NO 2), SO 2, CO 2 (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja CO, NO i NO , NO (NO i NO 2 x 2 w przeliczeniu na NO 2), SO 2, CO 2 (z obliczeń) Gazy odlotowe Emisja CO, NO i NO , NO (NO i NO 2 x 2 w przeliczeniu na NO 2), SO 2, CO 2 (z obliczen)","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of CO, NO and NO , NO (NO and NO 2 x 2 calculated as NO 2), SO 2, CO 2 (calculated)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a56029af9f73f382540de","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania związków organicznych Metoda z zastosowaniem węgla aktywnego/żelu krzemionkowego/roztworów pochłaniających","methodology_en":"Sampling for determination of organic compounds Method using activated carbon/silica gel/absorbing solutions","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania związków organicznych Metoda z zastosowaniem węgla aktywnego/żelu krzemionkowego/roztworów pochłaniających","reference":"PN-Z-04008-4:1999","norm_bases":["PN-Z-04008-4:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania związków organicznych Metoda z zastosowaniem węgla aktywnego/żelu krzemionkowego/roztworów pochłaniających PN-Z-04008-4:1999 Gazy odlotowe Pobieranie probek do oznaczania zwiazkow organicznych Metoda z zastosowaniem wegla aktywnego/zelu krzemionkowego/roztworow pochlaniajacych PN-Z-04008-4:1999","categories":["other"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of organic compounds Method using activated carbon/silica gel/absorbing solutions PN-Z-04008-4:1999","search_zh":"废气 PN-Z-04008-4:1999","test_object_zh":"废气"},{"_id":"6a5a56029af9f73f382540df","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja związków organicznych (z obliczeń)","methodology_en":"Emission of organic compounds (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja związków organicznych (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja związków organicznych (z obliczeń) Gazy odlotowe Emisja zwiazkow organicznych (z obliczen)","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of organic compounds (calculated)","search_zh":"废气 有机化合物排放量（计算值）","test_object_zh":"废气","methodology_zh":"有机化合物排放量（计算值）"},{"_id":"6a5a56029af9f73f382540e0","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania chlorowodoru","methodology_en":"Sampling for the determination of hydrogen chloride","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania chlorowodoru","reference":"PN-EN-1911:2011","norm_bases":["PN-EN-1911:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania chlorowodoru PN-EN-1911:2011 Gazy odlotowe Pobieranie probek do oznaczania chlorowodoru PN-EN-1911:2011","categories":["other"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for the determination of hydrogen chloride PN-EN-1911:2011","search_zh":"废气 用于测定氯化氢的采样 PN-EN-1911:2011","test_object_zh":"废气","methodology_zh":"用于测定氯化氢的采样"},{"_id":"6a5a56029af9f73f382540e1","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja chlorowodoru (z obliczeń)","methodology_en":"Hydrogen chloride emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja chlorowodoru (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja chlorowodoru (z obliczeń) Gazy odlotowe Emisja chlorowodoru (z obliczen)","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Hydrogen chloride emission (calculated)","search_zh":"废气 氯化氢排放量（计算值）","test_object_zh":"废气","methodology_zh":"氯化氢排放量（计算值）"},{"_id":"6a5a56029af9f73f382540e2","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","methodology_en":"Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2005 Gazy odlotowe Pobieranie probek do oznaczania stezenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2005","categories":["materials"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V PN-EN 14385:2005","search_zh":"废气 用于测定金属浓度的采样：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V PN-EN 14385:2005","test_object_zh":"废气","methodology_zh":"用于测定金属浓度的采样：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V"},{"_id":"6a5a56029af9f73f382540e3","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","methodology_en":"Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczeń) Gazy odlotowe Emisja metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (z obliczen)","categories":["materials","environment"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of metals: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V (calculated)","search_zh":"废气 金属排放：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V（由计算得出）","test_object_zh":"废气","methodology_zh":"金属排放：As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Tl、V（由计算得出）"},{"_id":"6a5a56029af9f73f382540e4","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","methodology_en":"Sampling for determination of total mercury concentration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia rtęci ogólnej PN-EN 13211+AC:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia rteci ogolnej PN-EN 13211+AC:2006","categories":["other"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of total mercury concentration PN-EN 13211+AC:2006","search_zh":"废气 总汞浓度测定采样 PN-EN 13211+AC:2006","test_object_zh":"废气","methodology_zh":"总汞浓度测定采样"},{"_id":"6a5a56029af9f73f382540e5","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja rtęci ogólnej (z obliczeń)","methodology_en":"Total mercury emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja rtęci ogólnej (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja rtęci ogólnej (z obliczeń) Gazy odlotowe Emisja rteci ogolnej (z obliczen)","categories":["environment"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Total mercury emission (calculated)","search_zh":"废气 总汞排放量（计算值）","test_object_zh":"废气","methodology_zh":"总汞排放量（计算值）"},{"_id":"6a5a56029af9f73f382540e6","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia HF","methodology_en":"Sampling for determination of HF concentration","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia HF","reference":"ISO 15713:2006 CEN/TS 17340:2020-09","norm_bases":["ISO 15713:2006 CEN/TS 17340:2020-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia HF ISO 15713:2006 CEN/TS 17340:2020-09 Gazy odlotowe Pobieranie probek do oznaczania stezenia HF ISO 15713:2006 CEN/TS 17340:2020-09","categories":["other"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of HF concentration ISO 15713:2006 CEN/TS 17340:2020-09","search_zh":"废气 用于测定 HF 浓度的采样 ISO 15713:2006 CEN/TS 17340:2020-09","test_object_zh":"废气","methodology_zh":"用于测定 HF 浓度的采样"},{"_id":"6a5a56029af9f73f382540e7","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja HF (z obliczeń)","methodology_en":"HF emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja HF (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja HF (z obliczeń) Gazy odlotowe Emisja HF (z obliczen)","categories":["environment"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases HF emission (calculated)","search_zh":"废气 HF 排放量（计算值）","test_object_zh":"废气","methodology_zh":"HF 排放量（计算值）"},{"_id":"6a5a56029af9f73f382540e8","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie O 2 Zakres: (1,0 - 21,0) % Metoda paramagnetyczna (PMD)","methodology_en":"O 2 concentration Range: (1,0 - 21,0) % Paramagnetic method (PMD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie O 2 Zakres: (1,0 - 21,0) % Metoda paramagnetyczna (PMD)","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie O 2 Zakres: (1,0 - 21,0) % Metoda paramagnetyczna (PMD) PN-EN 14789:2017-04 Gazy odlotowe Stezenie O 2 Zakres: (1,0 - 21,0) % Metoda paramagnetyczna (PMD) PN-EN 14789:2017-04","categories":["other"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases O 2 concentration Range: (1,0 - 21,0) % Paramagnetic method (PMD) PN-EN 14789:2017-04","search_zh":"废气 PN-EN 14789:2017-04","test_object_zh":"废气"},{"_id":"6a5a56029af9f73f382540e9","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie CO 2 Zakres: (1,0 – 21,0) % Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","methodology_en":"CO 2 concentration Range: (1,0 – 21,0) % Non-dispersive infrared spectrometry method (NDIR)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie CO 2 Zakres: (1,0 – 21,0) % Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR)","reference":"ISO 12039:2019 CEN/TS 17405:2020","norm_bases":["ISO 12039:2019 CEN/TS 17405:2020"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie CO 2 Zakres: (1,0 – 21,0) % Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019 CEN/TS 17405:2020 Gazy odlotowe Stezenie CO 2 Zakres: (1,0 – 21,0) % Metoda niedyspersyjnej spektrometrii w podczerwieni (NDIR) ISO 12039:2019 CEN/TS 17405:2020","categories":["other"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases CO 2 concentration Range: (1,0 – 21,0) % Non-dispersive infrared spectrometry method (NDIR) ISO 12039:2019 CEN/TS 17405:2020","search_zh":"废气 ISO 12039:2019 CEN/TS 17405:2020","test_object_zh":"废气"},{"_id":"6a5a56029af9f73f382540ea","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja CO 2 (z obliczeń)","methodology_en":"CO 2 emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CO 2 (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja CO 2 (z obliczeń) Gazy odlotowe Emisja CO 2 (z obliczen)","categories":["environment"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases CO 2 emission (calculated)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a56029af9f73f382540eb","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie CO Zakres: (4,0 – 900) mg/m3 Metoda niedyspersyjnej spektometrii w podczerwieni (NDIR)","methodology_en":"CO concentration Range: (4,0 – 900) mg/m3 Non-dispersive infrared spectrometry method (NDIR)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie CO Zakres: (4,0 – 900) mg/m3 Metoda niedyspersyjnej spektometrii w podczerwieni (NDIR)","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie CO Zakres: (4,0 – 900) mg/m3 Metoda niedyspersyjnej spektometrii w podczerwieni (NDIR) PN-EN 15058:2017-04 Gazy odlotowe Stezenie CO Zakres: (4,0 – 900) mg/m3 Metoda niedyspersyjnej spektometrii w podczerwieni (NDIR) PN-EN 15058:2017-04","categories":["other"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases CO concentration Range: (4,0 – 900) mg/m3 Non-dispersive infrared spectrometry method (NDIR) PN-EN 15058:2017-04","search_zh":"废气 PN-EN 15058:2017-04","test_object_zh":"废气"},{"_id":"6a5a56029af9f73f382540ec","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja CO (z obliczeń)","methodology_en":"CO emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja CO (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja CO (z obliczeń) Gazy odlotowe Emisja CO (z obliczen)","categories":["environment"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases CO emission (calculated)","search_zh":"废气 CO 排放量（计算值）","test_object_zh":"废气","methodology_zh":"CO 排放量（计算值）"},{"_id":"6a5a56029af9f73f382540ed","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie NOx (NO i NO w 2 przeliczeniu na NO ) 2 Zakres: NOx (4,0 – 1400) mg/m3 Metoda chemiluminescencyjna (CLD)","methodology_en":"NOx concentration (NO and NO calculated as 2 NO ) 2 Range: NOx (4,0 – 1400) mg/m3 Chemiluminescence method (CLD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie NOx (NO i NO w 2 przeliczeniu na NO ) 2 Zakres: NOx (4,0 – 1400) mg/m3 Metoda chemiluminescencyjna (CLD)","reference":"PN-N 14792:2017-04","norm_bases":["PN-N 14792:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie NOx (NO i NO w 2 przeliczeniu na NO ) 2 Zakres: NOx (4,0 – 1400) mg/m3 Metoda chemiluminescencyjna (CLD) PN-N 14792:2017-04 Gazy odlotowe Stezenie NOx (NO i NO w 2 przeliczeniu na NO ) 2 Zakres: NOx (4,0 – 1400) mg/m3 Metoda chemiluminescencyjna (CLD) PN-N 14792:2017-04","categories":["other"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases NOx concentration (NO and NO calculated as 2 NO ) 2 Range: NOx (4,0 – 1400) mg/m3 Chemiluminescence method (CLD) PN-N 14792:2017-04","search_zh":"废气 PN-N 14792:2017-04","test_object_zh":"废气"},{"_id":"6a5a56029af9f73f382540ee","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja NOx (NO i NO w przeliczeniu na NO ) 2 2 (z obliczeń)","methodology_en":"Emission of NOx (NO and NO calculated as NO ) 2 2 (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja NOx (NO i NO w przeliczeniu na NO ) 2 2 (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja NOx (NO i NO w przeliczeniu na NO ) 2 2 (z obliczeń) Gazy odlotowe Emisja NOx (NO i NO w przeliczeniu na NO ) 2 2 (z obliczen)","categories":["environment"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of NOx (NO and NO calculated as NO ) 2 2 (calculated)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a56029af9f73f382540ef","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Stężenie tlenu, tlenku węgla, dwutlenku azotu, tlenku azotu, dwutlenku siarki Zakres: - O (3,0 – 21) % 2 - CO (6,0 – 1250) mg/m3 - NO (8,0 – 110) mg/m3 2 - NO (4,0 – 600) mg/m3 - SO (9,0 – 1200) mg/m3 2 Metoda elektrochemiczna","methodology_en":"Concentration of oxygen, carbon monoxide, nitrogen dioxide, nitrogen monoxide, sulphur dioxide Range: - O (3,0 – 21) % 2 - CO (6,0 – 1250) mg/m3 - NO (8,0 – 110) mg/m3 2 - NO (4,0 – 600) mg/m3 - SO (9,0 – 1200) mg/m3 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu, tlenku węgla, dwutlenku azotu, tlenku azotu, dwutlenku siarki Zakres: - O (3,0 – 21) % 2 - CO (6,0 – 1250) mg/m3 - NO (8,0 – 110) mg/m3 2 - NO (4,0 – 600) mg/m3 - SO (9,0 – 1200) mg/m3 2 Metoda elektrochemiczna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Stężenie tlenu, tlenku węgla, dwutlenku azotu, tlenku azotu, dwutlenku siarki Zakres: - O (3,0 – 21) % 2 - CO (6,0 – 1250) mg/m3 - NO (8,0 – 110) mg/m3 2 - NO (4,0 – 600) mg/m3 - SO (9,0 – 1200) mg/m3 2 Metoda elektrochemiczna PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenu, tlenku wegla, dwutlenku azotu, tlenku azotu, dwutlenku siarki Zakres: - O (3,0 – 21) % 2 - CO (6,0 – 1250) mg/m3 - NO (8,0 – 110) mg/m3 2 - NO (4,0 – 600) mg/m3 - SO (9,0 – 1200) mg/m3 2 Metoda elektrochemiczna PN-ISO 10396:2001","categories":["other"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Concentration of oxygen, carbon monoxide, nitrogen dioxide, nitrogen monoxide, sulphur dioxide Range: - O (3,0 – 21) % 2 - CO (6,0 – 1250) mg/m3 - NO (8,0 – 110) mg/m3 2 - NO (4,0 – 600) mg/m3 - SO (9,0 – 1200) mg/m3 2 Electrochemical method PN-ISO 10396:2001","search_zh":"废气 PN-ISO 10396:2001","test_object_zh":"废气"},{"_id":"6a5a56029af9f73f382540f0","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek pyłu do oznaczania stężenia Sn , Zn, Fe","methodology_en":"Dust sampling for determination of the concentration of Sn , Zn, Fe","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek pyłu do oznaczania stężenia Sn , Zn, Fe","reference":"PN-EN 14385:2005","norm_bases":["PN-EN 14385:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek pyłu do oznaczania stężenia Sn , Zn, Fe PN-EN 14385:2005 Gazy odlotowe Pobieranie probek pylu do oznaczania stezenia Sn , Zn, Fe PN-EN 14385:2005","categories":["other"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust sampling for determination of the concentration of Sn , Zn, Fe PN-EN 14385:2005","search_zh":"废气 PN-EN 14385:2005","test_object_zh":"废气"},{"_id":"6a5a56029af9f73f382540f1","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja Sn , Zn, Fe (z obliczeń)","methodology_en":"Emission of Sn , Zn, Fe (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja Sn , Zn, Fe (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja Sn , Zn, Fe (z obliczeń) Gazy odlotowe Emisja Sn , Zn, Fe (z obliczen)","categories":["environment"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of Sn , Zn, Fe (calculated)","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a56029af9f73f382540f2","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek pyłu do analizy granulometrycznej","methodology_en":"Dust sampling for particle size analysis","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek pyłu do analizy granulometrycznej","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek pyłu do analizy granulometrycznej PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek pylu do analizy granulometrycznej PN-Z-04030-7:1994","categories":["other"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Dust sampling for particle size analysis PN-Z-04030-7:1994","search_zh":"废气 用于粒度分析的粉尘采样 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"用于粒度分析的粉尘采样"},{"_id":"6a5a56029af9f73f382540f3","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja pyłu PM10, PM2,5 (z obliczeń)","methodology_en":"PM10, PM2,5 dust emission (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja pyłu PM10, PM2,5 (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja pyłu PM10, PM2,5 (z obliczeń) Gazy odlotowe Emisja pylu PM10, PM2,5 (z obliczen)","categories":["environment"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases PM10, PM2,5 dust emission (calculated)","search_zh":"废气 PM10、PM2,5 粉尘排放（由计算得出）","test_object_zh":"废气","methodology_zh":"PM10、PM2,5 粉尘排放（由计算得出）"},{"_id":"6a5a56029af9f73f382540f4","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Pobieranie próbek do oznaczania stężenia amoniaku (NH) 3","methodology_en":"Sampling for determination of ammonia concentration (NH) 3","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do oznaczania stężenia amoniaku (NH) 3","reference":"P/PLBŚ/10 wyd. I z dnia 09.07.2018r PN-EN ISO 21877:2020-03","norm_bases":["P/PLBŚ/10 wyd. I z dnia 09.07.2018r PN-EN ISO 21877:2020-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia amoniaku (NH) 3 P/PLBŚ/10 wyd. I z dnia 09.07.2018r PN-EN ISO 21877:2020-03 Gazy odlotowe Pobieranie probek do oznaczania stezenia amoniaku (NH) 3 P/PLBS/10 wyd. I z dnia 09.07.2018r PN-EN ISO 21877:2020-03","categories":["other"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Sampling for determination of ammonia concentration (NH) 3 P/PLBŚ/10 wyd. I z dnia 09.07.2018r PN-EN ISO 21877:2020-03","search_zh":"废气 P/PLBŚ/10 wyd. I z dnia 09.07.2018r PN-EN ISO 21877:2020-03","test_object_zh":"废气"},{"_id":"6a5a56029af9f73f382540f5","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Gazy odlotowe","test_object_en":"Waste gases","methodology":"Emisja amoniaku (NH ) (z obliczeń) 3","methodology_en":"Emission of ammonia (NH ) (calculated) 3","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Emisja amoniaku (NH ) (z obliczeń) 3","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gazy odlotowe Emisja amoniaku (NH ) (z obliczeń) 3 Gazy odlotowe Emisja amoniaku (NH ) (z obliczen) 3","categories":["environment"],"row_index":31,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gases Emission of ammonia (NH ) (calculated) 3","search_zh":"废气","test_object_zh":"废气"},{"_id":"6a5a56029af9f73f382540f6","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Urządzenia odpylające gazy odlotowe","test_object_en":"Waste gas dedusting equipment","methodology":"Stężenie pyłu Zakres: (0,001 – 40) g/m3 Metoda grawimetryczna","methodology_en":"Dust concentration Range: (0,001 – 40) g/m3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie pyłu Zakres: (0,001 – 40) g/m3 Metoda grawimetryczna","reference":"PN-87/M-34129:1987 – metoda A PN-Z-04030-7:1994 PN-EN 13284-1:2018-02","norm_bases":["PN-87/M-34129:1987 – metoda A PN-Z-04030-7:1994 PN-EN 13284-1:2018-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia odpylające gazy odlotowe Stężenie pyłu Zakres: (0,001 – 40) g/m3 Metoda grawimetryczna PN-87/M-34129:1987 – metoda A PN-Z-04030-7:1994 PN-EN 13284-1:2018-02 Urzadzenia odpylajace gazy odlotowe Stezenie pylu Zakres: (0,001 – 40) g/m3 Metoda grawimetryczna PN-87/M-34129:1987 – metoda A PN-Z-04030-7:1994 PN-EN 13284-1:2018-02","categories":["other"],"row_index":32,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gas dedusting equipment Dust concentration Range: (0,001 – 40) g/m3 Gravimetric method PN-87/M-34129:1987 – metoda A PN-Z-04030-7:1994 PN-EN 13284-1:2018-02","search_zh":"废气除尘设备 PN-87/M-34129:1987 – metoda A PN-Z-04030-7:1994 PN-EN 13284-1:2018-02","test_object_zh":"废气除尘设备"},{"_id":"6a5a56029af9f73f382540f7","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Urządzenia odpylające gazy odlotowe","test_object_en":"Waste gas dedusting equipment","methodology":"Skuteczność odpylania (z obliczeń)","methodology_en":"Dust removal efficiency (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Skuteczność odpylania (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia odpylające gazy odlotowe Skuteczność odpylania (z obliczeń) Urzadzenia odpylajace gazy odlotowe Skutecznosc odpylania (z obliczen)","categories":["other"],"row_index":33,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Waste gas dedusting equipment Dust removal efficiency (calculated)","search_zh":"废气除尘设备 除尘效率（由计算得出）","test_object_zh":"废气除尘设备","methodology_zh":"除尘效率（由计算得出）"},{"_id":"6a5a56029af9f73f382540f8","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne podziemnych wyrobisk zakładów górniczych","test_object_en":"Workplace environment – electric lighting of underground workings of mining plants","methodology":"Natężenie oświetlenia Zakres: (0,5 – 3000) Ix Metoda pomiarowa bezpośrednia","methodology_en":"Illuminance Range: (0,5 – 3000) Ix Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie oświetlenia Zakres: (0,5 – 3000) Ix Metoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03 PN-G-02600:1996","norm_bases":["PN-83/E-04040.03 PN-G-02600:1996"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – oświetlenie elektryczne podziemnych wyrobisk zakładów górniczych Natężenie oświetlenia Zakres: (0,5 – 3000) Ix Metoda pomiarowa bezpośrednia PN-83/E-04040.03 PN-G-02600:1996 Srodowisko pracy – oswietlenie elektryczne podziemnych wyrobisk zakladow gorniczych Natezenie oswietlenia Zakres: (0,5 – 3000) Ix Metoda pomiarowa bezposrednia PN-83/E-04040.03 PN-G-02600:1996","categories":["environment"],"row_index":34,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – electric lighting of underground workings of mining plants Illuminance Range: (0,5 – 3000) Ix Direct measurement method PN-83/E-04040.03 PN-G-02600:1996"},{"_id":"6a5a56029af9f73f382540f9","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne podziemnych wyrobisk zakładów górniczych","test_object_en":"Workplace environment – electric lighting of underground workings of mining plants","methodology":"Równomierność oświetlenia (z obliczeń)","methodology_en":"Illuminance uniformity (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – oświetlenie elektryczne podziemnych wyrobisk zakładów górniczych Równomierność oświetlenia (z obliczeń) Srodowisko pracy – oswietlenie elektryczne podziemnych wyrobisk zakladow gorniczych Rownomiernosc oswietlenia (z obliczen)","categories":["environment"],"row_index":35,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – electric lighting of underground workings of mining plants Illuminance uniformity (calculated)","methodology_zh":"照度均匀度（计算值）","search_zh":"照度均匀度（计算值）"},{"_id":"6a5a56029af9f73f382540fa","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne powierzchni podziemnych zakładów górniczych","test_object_en":"Workplace environment – electric lighting of surface areas of underground mining plants","methodology":"Natężenie oświetlenia Zakres: (0,5 – 10000) Ix Metoda pomiarowa bezpośrednia","methodology_en":"Illuminance Range: (0,5 – 10000) Ix Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie oświetlenia Zakres: (0,5 – 10000) Ix Metoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03 PN-G-02601:1999","norm_bases":["PN-83/E-04040.03 PN-G-02601:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – oświetlenie elektryczne powierzchni podziemnych zakładów górniczych Natężenie oświetlenia Zakres: (0,5 – 10000) Ix Metoda pomiarowa bezpośrednia PN-83/E-04040.03 PN-G-02601:1999 Srodowisko pracy – oswietlenie elektryczne powierzchni podziemnych zakladow gorniczych Natezenie oswietlenia Zakres: (0,5 – 10000) Ix Metoda pomiarowa bezposrednia PN-83/E-04040.03 PN-G-02601:1999","categories":["environment"],"row_index":36,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – electric lighting of surface areas of underground mining plants Illuminance Range: (0,5 – 10000) Ix Direct measurement method PN-83/E-04040.03 PN-G-02601:1999","methodology_zh":"照度 范围：(0,5 – 10000) lx 直接测量法","search_zh":"照度 范围：(0,5 – 10000) lx 直接测量法 PN-83/E-04040.03 PN-G-02601:1999"},{"_id":"6a5a56029af9f73f382540fb","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne powierzchni podziemnych zakładów górniczych","test_object_en":"Workplace environment – electric lighting of surface areas of underground mining plants","methodology":"Równomierność oświetlenia (z obliczeń)","methodology_en":"Illuminance uniformity (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – oświetlenie elektryczne powierzchni podziemnych zakładów górniczych Równomierność oświetlenia (z obliczeń) Srodowisko pracy – oswietlenie elektryczne powierzchni podziemnych zakladow gorniczych Rownomiernosc oswietlenia (z obliczen)","categories":["environment"],"row_index":37,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment – electric lighting of surface areas of underground mining plants Illuminance uniformity (calculated)","methodology_zh":"照度均匀度（计算值）","search_zh":"照度均匀度（计算值）"},{"_id":"6a5a56029af9f73f382540fc","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Środowisko pracy oraz pomieszczenia w budynkach – oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment and rooms in buildings – indoor electric lighting","methodology":"Natężenie oświetlenia Zakres: (0,5 – 10000) Ix Metoda pomiarowa bezpośrednia","methodology_en":"Illuminance Range: (0,5 – 10000) Ix Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie oświetlenia Zakres: (0,5 – 10000) Ix Metoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy oraz pomieszczenia w budynkach – oświetlenie elektryczne we wnętrzach Natężenie oświetlenia Zakres: (0,5 – 10000) Ix Metoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy oraz pomieszczenia w budynkach – oswietlenie elektryczne we wnetrzach Natezenie oswietlenia Zakres: (0,5 – 10000) Ix Metoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":38,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment and rooms in buildings – indoor electric lighting Illuminance Range: (0,5 – 10000) Ix Direct measurement method PN-83/E-04040.03","methodology_zh":"照度 范围：(0,5 – 10000) lx 直接测量法","search_zh":"照度 范围：(0,5 – 10000) lx 直接测量法 PN-83/E-04040.03"},{"_id":"6a5a56029af9f73f382540fd","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Środowisko pracy oraz pomieszczenia w budynkach – oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment and rooms in buildings – indoor electric lighting","methodology":"Równomierność oświetlenia (z obliczeń)","methodology_en":"Illuminance uniformity (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy oraz pomieszczenia w budynkach – oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) Srodowisko pracy oraz pomieszczenia w budynkach – oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen)","categories":["environment"],"row_index":39,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment and rooms in buildings – indoor electric lighting Illuminance uniformity (calculated)","methodology_zh":"照度均匀度（计算值）","search_zh":"照度均匀度（计算值）"},{"_id":"6a5a56029af9f73f382540fe","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Środowisko pracy oraz środowisko ogólne – oświetlenie elektryczne na zewnątrz","test_object_en":"Workplace environment and general environment – outdoor electric lighting","methodology":"Natężenie oświetlenia Zakres: (0,5 – 10000) Ix Metoda pomiarowa bezpośrednia","methodology_en":"Illuminance Range: (0,5 – 10000) Ix Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie oświetlenia Zakres: (0,5 – 10000) Ix Metoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03 PN-EN 12464-2:2014-05","norm_bases":["PN-83/E-04040.03 PN-EN 12464-2:2014-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy oraz środowisko ogólne – oświetlenie elektryczne na zewnątrz Natężenie oświetlenia Zakres: (0,5 – 10000) Ix Metoda pomiarowa bezpośrednia PN-83/E-04040.03 PN-EN 12464-2:2014-05 Srodowisko pracy oraz srodowisko ogolne – oswietlenie elektryczne na zewnatrz Natezenie oswietlenia Zakres: (0,5 – 10000) Ix Metoda pomiarowa bezposrednia PN-83/E-04040.03 PN-EN 12464-2:2014-05","categories":["environment"],"row_index":40,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment and general environment – outdoor electric lighting Illuminance Range: (0,5 – 10000) Ix Direct measurement method PN-83/E-04040.03 PN-EN 12464-2:2014-05","methodology_zh":"照度 范围：(0,5 – 10000) lx 直接测量法","search_zh":"工作环境与一般环境 － 室外电气照明 照度 范围：(0,5 – 10000) lx 直接测量法 PN-83/E-04040.03 PN-EN 12464-2:2014-05","test_object_zh":"工作环境与一般环境 － 室外电气照明"},{"_id":"6a5a56029af9f73f382540ff","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Środowisko pracy oraz środowisko ogólne – oświetlenie elektryczne na zewnątrz","test_object_en":"Workplace environment and general environment – outdoor electric lighting","methodology":"Równomierność oświetlenia (z obliczeń)","methodology_en":"Illuminance uniformity (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy oraz środowisko ogólne – oświetlenie elektryczne na zewnątrz Równomierność oświetlenia (z obliczeń) Srodowisko pracy oraz srodowisko ogolne – oswietlenie elektryczne na zewnatrz Rownomiernosc oswietlenia (z obliczen)","categories":["environment"],"row_index":41,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment and general environment – outdoor electric lighting Illuminance uniformity (calculated)","methodology_zh":"照度均匀度（计算值）","search_zh":"工作环境与一般环境 － 室外电气照明 照度均匀度（计算值）","test_object_zh":"工作环境与一般环境 － 室外电气照明"},{"_id":"6a5a56029af9f73f38254100","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Środowisko pracy oraz środowisko ogólne – oświetlenie elektryczne na zewnątrz","test_object_en":"Workplace environment and general environment – outdoor electric lighting","methodology":"Zróżnicowanie oświetlenia (z obliczeń)","methodology_en":"Illumination variation (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zróżnicowanie oświetlenia (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy oraz środowisko ogólne – oświetlenie elektryczne na zewnątrz Zróżnicowanie oświetlenia (z obliczeń) Srodowisko pracy oraz srodowisko ogolne – oswietlenie elektryczne na zewnatrz Zroznicowanie oswietlenia (z obliczen)","categories":["environment"],"row_index":42,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment and general environment – outdoor electric lighting Illumination variation (calculated)","search_zh":"工作环境与一般环境 － 室外电气照明","test_object_zh":"工作环境与一般环境 － 室外电气照明"},{"_id":"6a5a56029af9f73f38254101","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Środowisko pracy oraz pomieszczenia w budynkach – oświetlenie elektryczne awaryjne","test_object_en":"Workplace environment and rooms in buildings – emergency electric lighting","methodology":"Natężenie oświetlenia Zakres: (0,5 – 200) Ix Metoda pomiarowa bezpośrednia","methodology_en":"Illuminance Range: (0,5 – 200) Ix Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie oświetlenia Zakres: (0,5 – 200) Ix Metoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy oraz pomieszczenia w budynkach – oświetlenie elektryczne awaryjne Natężenie oświetlenia Zakres: (0,5 – 200) Ix Metoda pomiarowa bezpośrednia PN-EN 1838:2013-11 z wyłączeniem pkt. 5 Srodowisko pracy oraz pomieszczenia w budynkach – oswietlenie elektryczne awaryjne Natezenie oswietlenia Zakres: (0,5 – 200) Ix Metoda pomiarowa bezposrednia PN-EN 1838:2013-11 z wylaczeniem pkt. 5","categories":["environment"],"row_index":43,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment and rooms in buildings – emergency electric lighting Illuminance Range: (0,5 – 200) Ix Direct measurement method PN-EN 1838:2013-11 z wyłączeniem pkt. 5","search_zh":"工作环境与建筑物内房间 － 应急电气照明 PN-EN 1838:2013-11 z wyłączeniem pkt. 5","test_object_zh":"工作环境与建筑物内房间 － 应急电气照明"},{"_id":"6a5a56029af9f73f38254102","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Środowisko pracy oraz pomieszczenia w budynkach – oświetlenie elektryczne awaryjne","test_object_en":"Workplace environment and rooms in buildings – emergency electric lighting","methodology":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (obliczeń)","methodology_en":"Ratio of minimum to maximum illuminance (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy oraz pomieszczenia w budynkach – oświetlenie elektryczne awaryjne Stosunek minimalnego do maksymalnego natężenia oświetlenia (obliczeń) Srodowisko pracy oraz pomieszczenia w budynkach – oswietlenie elektryczne awaryjne Stosunek minimalnego do maksymalnego natezenia oswietlenia (obliczen)","categories":["environment"],"row_index":44,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment and rooms in buildings – emergency electric lighting Ratio of minimum to maximum illuminance (calculated)","search_zh":"工作环境与建筑物内房间 － 应急电气照明","test_object_zh":"工作环境与建筑物内房间 － 应急电气照明"},{"_id":"6a5a56029af9f73f38254103","lab_id":"69ad52a3de79e566650fb52e","country":"PL","accr_number":"AB 1028","accr_body":"PCA","test_object":"Środowisko pracy oraz pomieszczenia w budynkach – oświetlenie elektryczne awaryjne","test_object_en":"Workplace environment and rooms in buildings – emergency electric lighting","methodology":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","methodology_en":"Illuminance uniformity for the high-risk zone (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy oraz pomieszczenia w budynkach – oświetlenie elektryczne awaryjne Równomierność oświetlenia dla strefy wysokiego ryzyka (z obliczeń) Srodowisko pracy oraz pomieszczenia w budynkach – oswietlenie elektryczne awaryjne Rownomiernosc oswietlenia dla strefy wysokiego ryzyka (z obliczen)","categories":["environment"],"row_index":45,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Workplace environment and rooms in buildings – emergency electric lighting Illuminance uniformity for the high-risk zone (calculated)","methodology_zh":"高风险区照度均匀度（计算值）","search_zh":"工作环境与建筑物内房间 － 应急电气照明 高风险区照度均匀度（计算值）","test_object_zh":"工作环境与建筑物内房间 － 应急电气照明"}],"has_pdf":true}