🇵🇱 POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA PL

PCA AB 1027 • Przeworsk, Poland • 15 methods

Water & wastewaterMicrobiology

POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA is a laboratory accredited by PCA under number AB 1027 (Przeworsk, Poland). Its accreditation scope covers 15 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Faecal swab.

At a glance

  • Accreditation number: PCA AB 1027
  • Methods in scope: 15
  • Types of test objects: 2
  • City: Przeworsk, Poland
Accreditation number
AB 1027
Accreditation body
PCA
Address
W PRZEWORSKU, ul. Rynek 1, 37-200 Przeworsk
City
Przeworsk, Poland

What this laboratory tests (2)

Accreditation scope — test methods (15)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Nitrite concentration Range: (0,010 − 0,70) mg/l Spectrophotometric method PB/PC/03 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8507
2 Water intended for human consumption Nitrite concentration Range: (0,030 − 0,66) mg/l Spectrophotometric method PN-EN 26777:1999
3 Water intended for human consumption Nitrate concentration Range: (0,6 − 18,0) mg/l Spectrophotometric method PB/PC/04 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8171
4 Water intended for human consumption Iron concentration Range: (0,060 − 1) mg/l Spectrophotometric method PB/PC/06 wydanie 7 z dnia 21.12.2020 r. na podstawie testu HACH Nr 8147
5 Water intended for human consumption Ammonium ion concentration Range: (0,06 − 1,40) mg/l Spectrophotometric method PB/PC/07 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8038
6 Water intended for human consumption Ammonium nitrogen concentration Range: (0,040 − 2,0) mg/l Spectrophotometric method PN-C-04576-4:1994
7 Water intended for human consumption Manganese concentration Range: (0,015 − 0,070) mg/l Spectrophotometric method PB/PC/08 wydanie 8 z dnia 22.11.2021r. na podstawie testu HACH Nr 8149
8 Water intended for human consumption Electrical conductivity Range: (140 − 5000) μS/cm Conductometric method PN-EN 27888:1999
9 Water intended for human consumption pH Range: 4,0 − 10,0 Potentiometric method PN-EN ISO 10523:2012
10 Water intended for human consumption Turbidity Range: (0,30 − 20) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
11 Water intended for human consumption Colour Range: (2 – 30) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C
12 Water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
13 Water intended for human consumption Coliform bacteria and Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014- 12+A1:2017
14 Water intended for human consumption Total count of microorganisms at 22°C Plate method PN-EN ISO 6222:2004
15 Faecal swab Presence and identification of Salmonella and Shigella rods Culture method with biochemical and serological confirmation PB/SJ/01 wydanie 8 z dnia 01.10.2024 r.

Reference standards (15)

PB/PC/03 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8507
PB/PC/04 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8171
PB/PC/06 wydanie 7 z dnia 21.12.2020 r. na podstawie testu HACH Nr 8147
PB/PC/07 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8038
PB/PC/08 wydanie 8 z dnia 22.11.2021r. na podstawie testu HACH Nr 8149
PB/SJ/01 wydanie 8 z dnia 01.10.2024 r.
PN-C-04576-4:1994
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014- 12+A1:2017