{"lab":{"_id":"69ad52a3de79e566650fb52c","accr_number":"AB 1027","country":"PL","accr_body":"PCA","address":"W PRZEWORSKU, ul. Rynek 1, 37-200 Przeworsk","categories":["water","microbiology"],"city":"Przeworsk","imported_at":"2026-03-08T10:42:43.265Z","methods_count":15,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1027.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w przeworsku, ul. rynek 1, 37-200 przeworsk water other pharma electronics microbiology food","status":"active","updated_at":"2026-03-08T14:50:12.174Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:12.174Z","parse_date":"2026-07-17T16:19:14.068Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://www.gov.pl/web/psse-przeworsk/kontakt2","fields_of_testing":[{"codes":"C/29","pl":"Badania chemiczne wody do spożycia przez ludzi","en":"Chemical tests of drinking water"},{"codes":"K/3; K/29","pl":"Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań, wody do spożycia przez ludzi","en":"Microbiological tests of biological items and materials for testing, drinking water"},{"codes":"N/29","pl":"Badania właściwości fizycznych wody do spożycia przez ludzi","en":"Tests of physical properties of drinking water"}],"issue":{"no":"16","date":"25.02.2025"},"map_coord":[50.056757,22.494502],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":14,"microbiology":2},"category_scores":{"water":12.25,"microbiology":0.25},"has_zh":true},"methods":[{"_id":"6a5a56029af9f73f382540c7","lab_id":"69ad52a3de79e566650fb52c","country":"PL","accr_number":"AB 1027","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie azotynów Zakres: (0,010 − 0,70) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite concentration Range: (0,010 − 0,70) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów Zakres: (0,010 − 0,70) mg/l Metoda spektrofotometryczna","reference":"PB/PC/03 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8507","norm_bases":["PB/PC/03 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8507"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie azotynów Zakres: (0,010 − 0,70) mg/l Metoda spektrofotometryczna PB/PC/03 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8507 Woda do spozycia przez ludzi Stezenie azotynow Zakres: (0,010 − 0,70) mg/l Metoda spektrofotometryczna PB/PC/03 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8507","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Nitrite concentration Range: (0,010 − 0,70) mg/l Spectrophotometric method PB/PC/03 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8507","search_zh":"生活饮用水 PB/PC/03 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8507","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f382540c8","lab_id":"69ad52a3de79e566650fb52c","country":"PL","accr_number":"AB 1027","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie azotynów Zakres: (0,030 − 0,66) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite concentration Range: (0,030 − 0,66) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów Zakres: (0,030 − 0,66) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie azotynów Zakres: (0,030 − 0,66) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi Stezenie azotynow Zakres: (0,030 − 0,66) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Nitrite concentration Range: (0,030 − 0,66) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"生活饮用水 PN-EN 26777:1999","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f382540c9","lab_id":"69ad52a3de79e566650fb52c","country":"PL","accr_number":"AB 1027","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie azotanów Zakres: (0,6 − 18,0) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate concentration Range: (0,6 − 18,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotanów Zakres: (0,6 − 18,0) mg/l Metoda spektrofotometryczna","reference":"PB/PC/04 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8171","norm_bases":["PB/PC/04 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8171"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie azotanów Zakres: (0,6 − 18,0) mg/l Metoda spektrofotometryczna PB/PC/04 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8171 Woda do spozycia przez ludzi Stezenie azotanow Zakres: (0,6 − 18,0) mg/l Metoda spektrofotometryczna PB/PC/04 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8171","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Nitrate concentration Range: (0,6 − 18,0) mg/l Spectrophotometric method PB/PC/04 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8171","search_zh":"生活饮用水 PB/PC/04 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8171","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f382540ca","lab_id":"69ad52a3de79e566650fb52c","country":"PL","accr_number":"AB 1027","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie żelaza Zakres: (0,060 − 1) mg/l Metoda spektrofotometryczna","methodology_en":"Iron concentration Range: (0,060 − 1) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza Zakres: (0,060 − 1) mg/l Metoda spektrofotometryczna","reference":"PB/PC/06 wydanie 7 z dnia 21.12.2020 r. na podstawie testu HACH Nr 8147","norm_bases":["PB/PC/06 wydanie 7 z dnia 21.12.2020 r. na podstawie testu HACH Nr 8147"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza Zakres: (0,060 − 1) mg/l Metoda spektrofotometryczna PB/PC/06 wydanie 7 z dnia 21.12.2020 r. na podstawie testu HACH Nr 8147 Woda do spozycia przez ludzi Stezenie zelaza Zakres: (0,060 − 1) mg/l Metoda spektrofotometryczna PB/PC/06 wydanie 7 z dnia 21.12.2020 r. na podstawie testu HACH Nr 8147","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Iron concentration Range: (0,060 − 1) mg/l Spectrophotometric method PB/PC/06 wydanie 7 z dnia 21.12.2020 r. na podstawie testu HACH Nr 8147","search_zh":"生活饮用水 PB/PC/06 wydanie 7 z dnia 21.12.2020 r. na podstawie testu HACH Nr 8147","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f382540cb","lab_id":"69ad52a3de79e566650fb52c","country":"PL","accr_number":"AB 1027","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie amonowego jonu Zakres: (0,06 − 1,40) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium ion concentration Range: (0,06 − 1,40) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie amonowego jonu Zakres: (0,06 − 1,40) mg/l Metoda spektrofotometryczna","reference":"PB/PC/07 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8038","norm_bases":["PB/PC/07 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8038"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie amonowego jonu Zakres: (0,06 − 1,40) mg/l Metoda spektrofotometryczna PB/PC/07 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8038 Woda do spozycia przez ludzi Stezenie amonowego jonu Zakres: (0,06 − 1,40) mg/l Metoda spektrofotometryczna PB/PC/07 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8038","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Ammonium ion concentration Range: (0,06 − 1,40) mg/l Spectrophotometric method PB/PC/07 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8038","search_zh":"生活饮用水 PB/PC/07 wydanie 6 z dnia 22.11.2021r. na podstawie testu HACH Nr 8038","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f382540cc","lab_id":"69ad52a3de79e566650fb52c","country":"PL","accr_number":"AB 1027","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie azotu amonowego Zakres: (0,040 − 2,0) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium nitrogen concentration Range: (0,040 − 2,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,040 − 2,0) mg/l Metoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie azotu amonowego Zakres: (0,040 − 2,0) mg/l Metoda spektrofotometryczna PN-C-04576-4:1994 Woda do spozycia przez ludzi Stezenie azotu amonowego Zakres: (0,040 − 2,0) mg/l Metoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Ammonium nitrogen concentration Range: (0,040 − 2,0) mg/l Spectrophotometric method PN-C-04576-4:1994","search_zh":"生活饮用水 PN-C-04576-4:1994","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f382540cd","lab_id":"69ad52a3de79e566650fb52c","country":"PL","accr_number":"AB 1027","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Stężenie manganu Zakres: (0,015 − 0,070) mg/l Metoda spektrofotometryczna","methodology_en":"Manganese concentration Range: (0,015 − 0,070) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie manganu Zakres: (0,015 − 0,070) mg/l Metoda spektrofotometryczna","reference":"PB/PC/08 wydanie 8 z dnia 22.11.2021r. na podstawie testu HACH Nr 8149","norm_bases":["PB/PC/08 wydanie 8 z dnia 22.11.2021r. na podstawie testu HACH Nr 8149"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Stężenie manganu Zakres: (0,015 − 0,070) mg/l Metoda spektrofotometryczna PB/PC/08 wydanie 8 z dnia 22.11.2021r. na podstawie testu HACH Nr 8149 Woda do spozycia przez ludzi Stezenie manganu Zakres: (0,015 − 0,070) mg/l Metoda spektrofotometryczna PB/PC/08 wydanie 8 z dnia 22.11.2021r. na podstawie testu HACH Nr 8149","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Manganese concentration Range: (0,015 − 0,070) mg/l Spectrophotometric method PB/PC/08 wydanie 8 z dnia 22.11.2021r. na podstawie testu HACH Nr 8149","search_zh":"生活饮用水 PB/PC/08 wydanie 8 z dnia 22.11.2021r. na podstawie testu HACH Nr 8149","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f382540ce","lab_id":"69ad52a3de79e566650fb52c","country":"PL","accr_number":"AB 1027","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Przewodność elektryczna właściwa Zakres: (140 − 5000) μS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (140 − 5000) μS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (140 − 5000) μS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa Zakres: (140 − 5000) μS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa Zakres: (140 − 5000) μS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Electrical conductivity Range: (140 − 5000) μS/cm Conductometric method PN-EN 27888:1999","search_zh":"生活饮用水 PN-EN 27888:1999","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f382540cf","lab_id":"69ad52a3de79e566650fb52c","country":"PL","accr_number":"AB 1027","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"pH Zakres: 4,0 − 10,0 Metoda potencjometryczna","methodology_en":"pH Range: 4,0 − 10,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH Zakres: 4,0 − 10,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi pH Zakres: 4,0 − 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH Zakres: 4,0 − 10,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption pH Range: 4,0 − 10,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"生活饮用水 PN-EN ISO 10523:2012","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f382540d0","lab_id":"69ad52a3de79e566650fb52c","country":"PL","accr_number":"AB 1027","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Mętność Zakres: (0,30 − 20) NTU Metoda nefelometryczna","methodology_en":"Turbidity Range: (0,30 − 20) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,30 − 20) NTU Metoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Mętność Zakres: (0,30 − 20) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc Zakres: (0,30 − 20) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Turbidity Range: (0,30 − 20) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","search_zh":"生活饮用水 PN-EN ISO 7027-1:2016-09","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f382540d1","lab_id":"69ad52a3de79e566650fb52c","country":"PL","accr_number":"AB 1027","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Barwa Zakres: (2 – 30) mg/l Pt Metoda spektrofotometryczna","methodology_en":"Colour Range: (2 – 30) mg/l Pt Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (2 – 30) mg/l Pt Metoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Barwa Zakres: (2 – 30) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C Woda do spozycia przez ludzi Barwa Zakres: (2 – 30) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Colour Range: (2 – 30) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","search_zh":"生活饮用水 PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f382540d2","lab_id":"69ad52a3de79e566650fb52c","country":"PL","accr_number":"AB 1027","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba enterokoków Metoda filtracji membranowej","methodology_en":"Enterococci count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba enterokoków Metoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków Metoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow Metoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"生活饮用水 肠球菌数 膜过滤法 PN-EN ISO 7899-2:2004","test_object_zh":"生活饮用水","methodology_zh":"肠球菌数 膜过滤法"},{"_id":"6a5a56029af9f73f382540d3","lab_id":"69ad52a3de79e566650fb52c","country":"PL","accr_number":"AB 1027","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba bakterii grupy coli i Escherichia coli Metoda filtracji membranowej","methodology_en":"Coliform bacteria and Escherichia coli count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli i Escherichia coli Metoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014- 12+A1:2017","norm_bases":["PN-EN ISO 9308-1:2014- 12+A1:2017"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli i Escherichia coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014- 12+A1:2017 Woda do spozycia przez ludzi Liczba bakterii grupy coli i Escherichia coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014- 12+A1:2017","categories":["microbiology","water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Coliform bacteria and Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014- 12+A1:2017","search_zh":"生活饮用水 大肠菌群与大肠埃希氏菌数 膜过滤法 PN-EN ISO 9308-1:2014- 12+A1:2017","test_object_zh":"生活饮用水","methodology_zh":"大肠菌群与大肠埃希氏菌数 膜过滤法"},{"_id":"6a5a56029af9f73f382540d4","lab_id":"69ad52a3de79e566650fb52c","country":"PL","accr_number":"AB 1027","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temp. 22°C Metoda płytkowa","methodology_en":"Total count of microorganisms at 22°C Plate method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22°C Metoda płytkowa","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 22°C Metoda płytkowa PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 22°C Metoda plytkowa PN-EN ISO 6222:2004","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water intended for human consumption Total count of microorganisms at 22°C Plate method PN-EN ISO 6222:2004","search_zh":"生活饮用水 PN-EN ISO 6222:2004","test_object_zh":"生活饮用水"},{"_id":"6a5a56029af9f73f382540d5","lab_id":"69ad52a3de79e566650fb52c","country":"PL","accr_number":"AB 1027","accr_body":"PCA","test_object":"Wymaz z kału","test_object_en":"Faecal swab","methodology":"Obecność i identyfikacja pałeczek Salmonella i Shigella Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","methodology_en":"Presence and identification of Salmonella and Shigella rods Culture method with biochemical and serological confirmation","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Obecność i identyfikacja pałeczek Salmonella i Shigella Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB/SJ/01 wydanie 8 z dnia 01.10.2024 r.","norm_bases":["PB/SJ/01 wydanie 8 z dnia 01.10.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wymaz z kału Obecność i identyfikacja pałeczek Salmonella i Shigella Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/SJ/01 wydanie 8 z dnia 01.10.2024 r. Wymaz z kalu Obecnosc i identyfikacja paleczek Salmonella i Shigella Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/SJ/01 wydanie 8 z dnia 01.10.2024 r.","categories":["microbiology"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Faecal swab Presence and identification of Salmonella and Shigella rods Culture method with biochemical and serological confirmation PB/SJ/01 wydanie 8 z dnia 01.10.2024 r."}],"has_pdf":true}