🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL
Water & wastewaterMicrobiology
PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 1012 (Starachowice, Poland). Its accreditation scope covers 31 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water Wastewater, Water, Sewage sludge, Wastewater.
At a glance
- Accreditation number: PCA AB 1012
- Methods in scope: 31
- Types of test objects: 4
- City: Starachowice, Poland
- Accreditation number
- AB 1012
- Accreditation body
- PCA
- Address
- ul. Iglasta 5, 27-200 Starachowice, LABORATORIUM, ul. Boczna 42
- City
- Starachowice, Poland
What this laboratory tests (4)
- Water Wastewater — 15 methods
- Water — 13 methods
- Sewage sludge — 2 methods
- Wastewater — 1 method
Accreditation scope — test methods (31)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Wastewater | Sampling for chemical and physical testing Manual and automatic method Temperature of wastewater/of the wastewater sample taken Range: (0,5 – 50) °C | PN-ISO 5667-10:2021-11 PN-77/C-04584 | ||
| 2 | Water | Sampling for chemical and physical testing Temperature of the water sample taken Range: (0,5 – 50) °C | PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 z wyłączeniem punktów 7.3 | PN-77/C-04584 | ||
| 3 | Water | Sampling for microbiological testing | PN-EN ISO 19458:2007 z wyłączeniem punktów 4.4.3 | ||
| 4 | Water Wastewater | pH + Range: 2,0 – 12,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 5 | Water Wastewater | Total suspended solids Range: (2,0 – 1500) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 6 | Water Wastewater | Biochemical oxygen demand - BOD 5 Range: (3 – 6000) mg/l O 2 Electrochemical method | PN-EN ISO 5815-1:2019-12 | ||
| 7 | Water Wastewater | Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/l O 2 Electrochemical method | PN-EN 1899-2:2002 | ||
| 8 | Water Wastewater | Dissolved oxygen concentration Range: (0,5 – 15) mg/l Oxygen saturation Range: (5 – 150) % Electrochemical method | PN-EN ISO 5814:2013-04 | ||
| 9 | Water Wastewater | Nitrite concentration Range: (0,006 – 7,2) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 10 | Water Wastewater | Ammonium nitrogen concentration Range: (0,15 – 700) mg/l Titrimetric method | PN-ISO 5664:2002 | ||
| 11 | Water Wastewater | Kjeldahl nitrogen concentration Range: (2,00 – 700) mg/l Titrimetric method | PN-EN 25663:2001 | ||
| 12 | Water Wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 13 | Water Wastewater | Chemical oxygen demand - COD-Cr Range: (15,0 – 2000) mg/l O 2 Spectrophotometric method | PN-ISO 15705:2005 | ||
| 14 | Water Wastewater | Total phosphorus concentration Range: (0,03 – 10) mg/l Spectrophotometric method | PB-05.00:2008 wydanie nr 2 z dnia 30.10.2008 r. na podstawie testu kuwetowego Merck Nr 1.14848 | ||
| 15 | Water Wastewater | Total phosphorus concentration Range: (0,050 – 25,0) mg/l Spectrophotometric method | PN-EN ISO 6878:2006 p.7+Ap2:2010 | ||
| 16 | Water Wastewater | Chloride concentration Range: (5,0 – 1000) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 17 | Water Wastewater | Nitrate concentration Range: (0,2 – 100,0) mg/l Nitrate nitrogen concentration Range: (0,2 – 50,0) mg/l Spectrophotometric method | PN-82/C-04576/08 | ||
| 18 | Water Wastewater | Mineral oil index (petroleum hydrocarbons C -C ) 10 40 Range: (0,30 – 20) mg/l Gas chromatography with flame ionisation detection (GC-FID) | PN-EN ISO 9377-2:2003 | ||
| 19 | Water | Total calcium and magnesium content (total hardness) Range: (5,0 – 1000) mg/l CaCO 3 Titrimetric method | PN-EN 6059:1999 | ||
| 20 | Water | Manganese concentration Range: (0,020 – 1,000) mg/l Spectrophotometric method | PN-92/C-04590/03 | ||
| 21 | Water | Ammonium ion concentration Range: (0,05 – 1,00) mg/l Spectrophotometric method | PN-ISO 7150-1:2002 | ||
| 22 | Water | Electrical conductivity Range: (10,0 – 2500) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 23 | Water | Turbidity Range: (0,20 – 100) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 24 | Water | Iron concentration Range: (0,030 – 4,000) mg/l Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | ||
| 25 | Water | Colour Range: (2 – 100) mg/l Pt Spectrophotometric method | PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06 | ||
| 26 | Water | Coliform bacteria count Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | ||
| 27 | Water | Escherichia coli count Membrane filtration method | |||
| 28 | Water | Enterococci (faecal streptococci) count Membrane filtration method | PN-EN ISO 7899-2:2004 | ||
| 29 | Water | Total viable count at 22°C Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 30 | Sewage sludge | Sampling for chemical, physical, biological and microbiological testing | PN-EN ISO 5667-13:2011 | ||
| 31 | Sewage sludge | Dry residue Range: (1,0 – 99,0) % Gravimetric method Water content (calculated) | PN-EN 12880:2004 | ||
Reference standards (31)
PB-05.00:2008 wydanie nr 2 z dnia 30.10.2008 r. na podstawie testu kuwetowego Merck Nr 1.14848
PN-73/C-04576/14
PN-77/C-04584
PN-82/C-04576/08
PN-92/C-04590/03
PN-EN 12880:2004
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 6059:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem punktów 4.4.3
PN-EN ISO 5667-13:2011
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p.7+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9377-2:2003
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 z wyłączeniem punktów 7.3
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9297:1994