🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL

PCA AB 1012 • Starachowice, Poland • 31 methods

Water & wastewaterMicrobiology

PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 1012 (Starachowice, Poland). Its accreditation scope covers 31 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water Wastewater, Water, Sewage sludge, Wastewater.

At a glance

  • Accreditation number: PCA AB 1012
  • Methods in scope: 31
  • Types of test objects: 4
  • City: Starachowice, Poland
Accreditation number
AB 1012
Accreditation body
PCA
Address
ul. Iglasta 5, 27-200 Starachowice, LABORATORIUM, ul. Boczna 42
City
Starachowice, Poland

What this laboratory tests (4)

Accreditation scope — test methods (31)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Wastewater Sampling for chemical and physical testing Manual and automatic method Temperature of wastewater/of the wastewater sample taken Range: (0,5 – 50) °C PN-ISO 5667-10:2021-11 PN-77/C-04584
2 Water Sampling for chemical and physical testing Temperature of the water sample taken Range: (0,5 – 50) °C PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 z wyłączeniem punktów 7.3 | PN-77/C-04584
3 Water Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem punktów 4.4.3
4 Water Wastewater pH + Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012
5 Water Wastewater Total suspended solids Range: (2,0 – 1500) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
6 Water Wastewater Biochemical oxygen demand - BOD 5 Range: (3 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12
7 Water Wastewater Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002
8 Water Wastewater Dissolved oxygen concentration Range: (0,5 – 15) mg/l Oxygen saturation Range: (5 – 150) % Electrochemical method PN-EN ISO 5814:2013-04
9 Water Wastewater Nitrite concentration Range: (0,006 – 7,2) mg/l Spectrophotometric method PN-EN 26777:1999
10 Water Wastewater Ammonium nitrogen concentration Range: (0,15 – 700) mg/l Titrimetric method PN-ISO 5664:2002
11 Water Wastewater Kjeldahl nitrogen concentration Range: (2,00 – 700) mg/l Titrimetric method PN-EN 25663:2001
12 Water Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14
13 Water Wastewater Chemical oxygen demand - COD-Cr Range: (15,0 – 2000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005
14 Water Wastewater Total phosphorus concentration Range: (0,03 – 10) mg/l Spectrophotometric method PB-05.00:2008 wydanie nr 2 z dnia 30.10.2008 r. na podstawie testu kuwetowego Merck Nr 1.14848
15 Water Wastewater Total phosphorus concentration Range: (0,050 – 25,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 p.7+Ap2:2010
16 Water Wastewater Chloride concentration Range: (5,0 – 1000) mg/l Titrimetric method PN-ISO 9297:1994
17 Water Wastewater Nitrate concentration Range: (0,2 – 100,0) mg/l Nitrate nitrogen concentration Range: (0,2 – 50,0) mg/l Spectrophotometric method PN-82/C-04576/08
18 Water Wastewater Mineral oil index (petroleum hydrocarbons C -C ) 10 40 Range: (0,30 – 20) mg/l Gas chromatography with flame ionisation detection (GC-FID) PN-EN ISO 9377-2:2003
19 Water Total calcium and magnesium content (total hardness) Range: (5,0 – 1000) mg/l CaCO 3 Titrimetric method PN-EN 6059:1999
20 Water Manganese concentration Range: (0,020 – 1,000) mg/l Spectrophotometric method PN-92/C-04590/03
21 Water Ammonium ion concentration Range: (0,05 – 1,00) mg/l Spectrophotometric method PN-ISO 7150-1:2002
22 Water Electrical conductivity Range: (10,0 – 2500) µS/cm Conductometric method PN-EN 27888:1999
23 Water Turbidity Range: (0,20 – 100) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
24 Water Iron concentration Range: (0,030 – 4,000) mg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
25 Water Colour Range: (2 – 100) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06
26 Water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
27 Water Escherichia coli count Membrane filtration method
28 Water Enterococci (faecal streptococci) count Membrane filtration method PN-EN ISO 7899-2:2004
29 Water Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004
30 Sewage sludge Sampling for chemical, physical, biological and microbiological testing PN-EN ISO 5667-13:2011
31 Sewage sludge Dry residue Range: (1,0 – 99,0) % Gravimetric method Water content (calculated) PN-EN 12880:2004

Reference standards (31)

PB-05.00:2008 wydanie nr 2 z dnia 30.10.2008 r. na podstawie testu kuwetowego Merck Nr 1.14848
PN-73/C-04576/14
PN-77/C-04584
PN-82/C-04576/08
PN-92/C-04590/03
PN-EN 12880:2004
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 6059:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007 z wyłączeniem punktów 4.4.3
PN-EN ISO 5667-13:2011
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p.7+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9377-2:2003
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 z wyłączeniem punktów 7.3
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9297:1994