{"lab":{"_id":"69ad52a3de79e566650fb518","accr_number":"AB 1012","country":"PL","accr_body":"PCA","address":"ul. Iglasta 5, 27-200 Starachowice, LABORATORIUM, ul. Boczna 42","categories":["water","microbiology"],"city":"Starachowice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":31,"name":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1012.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo wodociągów i kanalizacji sp. z o.o. ul. iglasta 5, 27-200 starachowice, laboratorium, ul. boczna 42 water other food pharma electronics microbiology","status":"active","updated_at":"2026-03-08T14:50:11.464Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:11.464Z","parse_date":"2026-07-17T16:19:13.785Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://pwik.starachowice.pl/informacje/20-oferta-badan.html","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"N/28/P; N/29/P; N/30/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów","en":"Tests of physical properties and sampling of water, drinking water, sewage, sediments"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"},{"codes":"P/32","pl":"Pobieranie próbek osadów","en":"Sampling of sediments"}],"issue":{"no":"20","date":"14.02.2025"},"map_coord":[51.058311,21.079804],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":31,"microbiology":4,"petro":1},"category_scores":{"water":26.69,"microbiology":0.44,"petro":0.03},"has_zh":true},"methods":[{"_id":"6a5a56019af9f73f38253fcd","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i automatyczna Temperatura ścieków/pobranej próbki ścieków Zakres: (0,5 – 50) °C","methodology_en":"Sampling for chemical and physical testing Manual and automatic method Temperature of wastewater/of the wastewater sample taken Range: (0,5 – 50) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i automatyczna Temperatura ścieków/pobranej próbki ścieków Zakres: (0,5 – 50) °C","reference":"PN-ISO 5667-10:2021-11 PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11 PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych Metoda manualna i automatyczna Temperatura ścieków/pobranej próbki ścieków Zakres: (0,5 – 50) °C PN-ISO 5667-10:2021-11 PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych Metoda manualna i automatyczna Temperatura sciekow/pobranej probki sciekow Zakres: (0,5 – 50) °C PN-ISO 5667-10:2021-11 PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method Temperature of wastewater/of the wastewater sample taken Range: (0,5 – 50) °C PN-ISO 5667-10:2021-11 PN-77/C-04584","search_zh":"污水 PN-ISO 5667-10:2021-11 PN-77/C-04584","test_object_zh":"污水"},{"_id":"6a5a56019af9f73f38253fce","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,5 – 50) °C","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken Range: (0,5 – 50) °C","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,5 – 50) °C","reference":"PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 z wyłączeniem punktów 7.3 | PN-77/C-04584","norm_bases":["PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 z wyłączeniem punktów 7.3","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody Zakres: (0,5 – 50) °C PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 z wyłączeniem punktów 7.3 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody Zakres: (0,5 – 50) °C PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 z wylaczeniem punktow 7.3 | PN-77/C-04584","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for chemical and physical testing Temperature of the water sample taken Range: (0,5 – 50) °C PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 z wyłączeniem punktów 7.3 | PN-77/C-04584","search_zh":"水 PN-ISO 5667-5:2017-10 PN-EN ISO 5667-6:2016-12 z wyłączeniem punktów 7.3 | PN-77/C-04584","test_object_zh":"水"},{"_id":"6a5a56019af9f73f38253fcf","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem punktów 4.4.3","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem punktów 4.4.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem punktów 4.4.3 Woda Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem punktow 4.4.3","categories":["water","microbiology"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem punktów 4.4.3","methodology_zh":"微生物检测用样品采集","search_zh":"水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem punktów 4.4.3","test_object_zh":"水"},{"_id":"6a5a56019af9f73f38253fd0","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"pH + Zakres: 2,0 – 12,0 Metoda potencjometryczna","methodology_en":"pH + Range: 2,0 – 12,0 Potentiometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"pH + Zakres: 2,0 – 12,0 Metoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki pH + Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012 Woda Scieki pH + Zakres: 2,0 – 12,0 Metoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater pH + Range: 2,0 – 12,0 Potentiometric method PN-EN ISO 10523:2012","search_zh":"水 废水 PN-EN ISO 10523:2012","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253fd1","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Zawiesiny ogólne Zakres: (2,0 – 1500) mg/l Metoda wagowa","methodology_en":"Total suspended solids Range: (2,0 – 1500) mg/l Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (2,0 – 1500) mg/l Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Zawiesiny ogólne Zakres: (2,0 – 1500) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007 Woda Scieki Zawiesiny ogolne Zakres: (2,0 – 1500) mg/l Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total suspended solids Range: (2,0 – 1500) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"水 废水 PN-EN 872:2007+Ap1:2007","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253fd2","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 6000) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (3 – 6000) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 6000) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (3 – 6000) mg/l O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Biochemical oxygen demand - BOD 5 Range: (3 – 6000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12","search_zh":"水 废水 五日生化需氧量 BZT 5 范围：(3 – 6000) mg/l O 2 电化学法 PN-EN ISO 5815-1:2019-12","test_object_zh":"水 废水","methodology_zh":"五日生化需氧量 BZT 5 范围：(3 – 6000) mg/l O 2 电化学法"},{"_id":"6a5a56019af9f73f38253fd3","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/l O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002 Woda Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/l O 2 Metoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002","search_zh":"水 废水 五日生化需氧量 BZT 5 范围：(0,5 – 6,0) mg/l O 2 电化学法 PN-EN 1899-2:2002","test_object_zh":"水 废水","methodology_zh":"五日生化需氧量 BZT 5 范围：(0,5 – 6,0) mg/l O 2 电化学法"},{"_id":"6a5a56019af9f73f38253fd4","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie tlenu rozpuszczonego Zakres: (0,5 – 15) mg/l Nasycenie tlenem Zakres: (5 – 150) % Metoda elektrochemiczna","methodology_en":"Dissolved oxygen concentration Range: (0,5 – 15) mg/l Oxygen saturation Range: (5 – 150) % Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego Zakres: (0,5 – 15) mg/l Nasycenie tlenem Zakres: (5 – 150) % Metoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie tlenu rozpuszczonego Zakres: (0,5 – 15) mg/l Nasycenie tlenem Zakres: (5 – 150) % Metoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda Scieki Stezenie tlenu rozpuszczonego Zakres: (0,5 – 15) mg/l Nasycenie tlenem Zakres: (5 – 150) % Metoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Dissolved oxygen concentration Range: (0,5 – 15) mg/l Oxygen saturation Range: (5 – 150) % Electrochemical method PN-EN ISO 5814:2013-04","search_zh":"水 废水 PN-EN ISO 5814:2013-04","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253fd5","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotynów Zakres: (0,006 – 7,2) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrite concentration Range: (0,006 – 7,2) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów Zakres: (0,006 – 7,2) mg/l Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotynów Zakres: (0,006 – 7,2) mg/l Metoda spektrofotometryczna PN-EN 26777:1999 Woda Scieki Stezenie azotynow Zakres: (0,006 – 7,2) mg/l Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Nitrite concentration Range: (0,006 – 7,2) mg/l Spectrophotometric method PN-EN 26777:1999","search_zh":"水 废水 PN-EN 26777:1999","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253fd6","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu amonowego Zakres: (0,15 – 700) mg/l Metoda miareczkowa","methodology_en":"Ammonium nitrogen concentration Range: (0,15 – 700) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego Zakres: (0,15 – 700) mg/l Metoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu amonowego Zakres: (0,15 – 700) mg/l Metoda miareczkowa PN-ISO 5664:2002 Woda Scieki Stezenie azotu amonowego Zakres: (0,15 – 700) mg/l Metoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Ammonium nitrogen concentration Range: (0,15 – 700) mg/l Titrimetric method PN-ISO 5664:2002","search_zh":"水 废水 PN-ISO 5664:2002","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253fd7","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu Kjeldahla Zakres: (2,00 – 700) mg/l Metoda miareczkowa","methodology_en":"Kjeldahl nitrogen concentration Range: (2,00 – 700) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (2,00 – 700) mg/l Metoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu Kjeldahla Zakres: (2,00 – 700) mg/l Metoda miareczkowa PN-EN 25663:2001 Woda Scieki Stezenie azotu Kjeldahla Zakres: (2,00 – 700) mg/l Metoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Kjeldahl nitrogen concentration Range: (2,00 – 700) mg/l Titrimetric method PN-EN 25663:2001","search_zh":"水 废水 PN-EN 25663:2001","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253fd8","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Woda Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14","methodology_zh":"总氮浓度（计算值）","search_zh":"水 废水 总氮浓度（计算值） PN-73/C-04576/14","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253fd9","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (15,0 – 2000) mg/l O 2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD-Cr Range: (15,0 – 2000) mg/l O 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (15,0 – 2000) mg/l O 2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (15,0 – 2000) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005 Woda Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (15,0 – 2000) mg/l O 2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Chemical oxygen demand - COD-Cr Range: (15,0 – 2000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"水 废水 PN-ISO 15705:2005","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253fda","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,03 – 10) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,03 – 10) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,03 – 10) mg/l Metoda spektrofotometryczna","reference":"PB-05.00:2008 wydanie nr 2 z dnia 30.10.2008 r. na podstawie testu kuwetowego Merck Nr 1.14848","norm_bases":["PB-05.00:2008 wydanie nr 2 z dnia 30.10.2008 r. na podstawie testu kuwetowego Merck Nr 1.14848"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie fosforu ogólnego Zakres: (0,03 – 10) mg/l Metoda spektrofotometryczna PB-05.00:2008 wydanie nr 2 z dnia 30.10.2008 r. na podstawie testu kuwetowego Merck Nr 1.14848 Woda Scieki Stezenie fosforu ogolnego Zakres: (0,03 – 10) mg/l Metoda spektrofotometryczna PB-05.00:2008 wydanie nr 2 z dnia 30.10.2008 r. na podstawie testu kuwetowego Merck Nr 1.14848","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total phosphorus concentration Range: (0,03 – 10) mg/l Spectrophotometric method PB-05.00:2008 wydanie nr 2 z dnia 30.10.2008 r. na podstawie testu kuwetowego Merck Nr 1.14848","search_zh":"水 废水 PB-05.00:2008 wydanie nr 2 z dnia 30.10.2008 r. na podstawie testu kuwetowego Merck Nr 1.14848","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253fdb","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,050 – 25,0) mg/l Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,050 – 25,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,050 – 25,0) mg/l Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p.7+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p.7+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie fosforu ogólnego Zakres: (0,050 – 25,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 p.7+Ap2:2010 Woda Scieki Stezenie fosforu ogolnego Zakres: (0,050 – 25,0) mg/l Metoda spektrofotometryczna PN-EN ISO 6878:2006 p.7+Ap2:2010","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total phosphorus concentration Range: (0,050 – 25,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 p.7+Ap2:2010","search_zh":"水 废水 PN-EN ISO 6878:2006 p.7+Ap2:2010","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253fdc","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie chlorków Zakres: (5,0 – 1000) mg/l Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5,0 – 1000) mg/l Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,0 – 1000) mg/l Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie chlorków Zakres: (5,0 – 1000) mg/l Metoda miareczkowa PN-ISO 9297:1994 Woda Scieki Stezenie chlorkow Zakres: (5,0 – 1000) mg/l Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Chloride concentration Range: (5,0 – 1000) mg/l Titrimetric method PN-ISO 9297:1994","search_zh":"水 废水 氯化物浓度 范围：(5,0 – 1000) mg/l 滴定法 PN-ISO 9297:1994","test_object_zh":"水 废水","methodology_zh":"氯化物浓度 范围：(5,0 – 1000) mg/l 滴定法"},{"_id":"6a5a56019af9f73f38253fdd","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotanów Zakres: (0,2 – 100,0) mg/l Stężenie azotu azotanowego Zakres: (0,2 – 50,0) mg/l Metoda spektrofotometryczna","methodology_en":"Nitrate concentration Range: (0,2 – 100,0) mg/l Nitrate nitrogen concentration Range: (0,2 – 50,0) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotanów Zakres: (0,2 – 100,0) mg/l Stężenie azotu azotanowego Zakres: (0,2 – 50,0) mg/l Metoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotanów Zakres: (0,2 – 100,0) mg/l Stężenie azotu azotanowego Zakres: (0,2 – 50,0) mg/l Metoda spektrofotometryczna PN-82/C-04576/08 Woda Scieki Stezenie azotanow Zakres: (0,2 – 100,0) mg/l Stezenie azotu azotanowego Zakres: (0,2 – 50,0) mg/l Metoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Nitrate concentration Range: (0,2 – 100,0) mg/l Nitrate nitrogen concentration Range: (0,2 – 50,0) mg/l Spectrophotometric method PN-82/C-04576/08","search_zh":"水 废水 PN-82/C-04576/08","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253fde","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Indeks oleju mineralnego (węglowodory ropopochodne C -C ) 10 40 Zakres: (0,30 – 20) mg/l Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","methodology_en":"Mineral oil index (petroleum hydrocarbons C -C ) 10 40 Range: (0,30 – 20) mg/l Gas chromatography with flame ionisation detection (GC-FID)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks oleju mineralnego (węglowodory ropopochodne C -C ) 10 40 Zakres: (0,30 – 20) mg/l Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Indeks oleju mineralnego (węglowodory ropopochodne C -C ) 10 40 Zakres: (0,30 – 20) mg/l Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda Scieki Indeks oleju mineralnego (weglowodory ropopochodne C -C ) 10 40 Zakres: (0,30 – 20) mg/l Metoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Mineral oil index (petroleum hydrocarbons C -C ) 10 40 Range: (0,30 – 20) mg/l Gas chromatography with flame ionisation detection (GC-FID) PN-EN ISO 9377-2:2003","search_zh":"水 废水 PN-EN ISO 9377-2:2003","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253fdf","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (5,0 – 1000) mg/l CaCO 3 Metoda miareczkowa","methodology_en":"Total calcium and magnesium content (total hardness) Range: (5,0 – 1000) mg/l CaCO 3 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (5,0 – 1000) mg/l CaCO 3 Metoda miareczkowa","reference":"PN-EN 6059:1999","norm_bases":["PN-EN 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (5,0 – 1000) mg/l CaCO 3 Metoda miareczkowa PN-EN 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna) Zakres: (5,0 – 1000) mg/l CaCO 3 Metoda miareczkowa PN-EN 6059:1999","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total calcium and magnesium content (total hardness) Range: (5,0 – 1000) mg/l CaCO 3 Titrimetric method PN-EN 6059:1999","search_zh":"水 PN-EN 6059:1999","test_object_zh":"水"},{"_id":"6a5a56019af9f73f38253fe0","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie manganu Zakres: (0,020 – 1,000) mg/l Metoda spektrofotometryczna","methodology_en":"Manganese concentration Range: (0,020 – 1,000) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie manganu Zakres: (0,020 – 1,000) mg/l Metoda spektrofotometryczna","reference":"PN-92/C-04590/03","norm_bases":["PN-92/C-04590/03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie manganu Zakres: (0,020 – 1,000) mg/l Metoda spektrofotometryczna PN-92/C-04590/03 Woda Stezenie manganu Zakres: (0,020 – 1,000) mg/l Metoda spektrofotometryczna PN-92/C-04590/03","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Manganese concentration Range: (0,020 – 1,000) mg/l Spectrophotometric method PN-92/C-04590/03","search_zh":"水 PN-92/C-04590/03","test_object_zh":"水"},{"_id":"6a5a56019af9f73f38253fe1","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie jonu amonowego Zakres: (0,05 – 1,00) mg/l Metoda spektrofotometryczna","methodology_en":"Ammonium ion concentration Range: (0,05 – 1,00) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego Zakres: (0,05 – 1,00) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie jonu amonowego Zakres: (0,05 – 1,00) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002 Woda Stezenie jonu amonowego Zakres: (0,05 – 1,00) mg/l Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Ammonium ion concentration Range: (0,05 – 1,00) mg/l Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"水 PN-ISO 7150-1:2002","test_object_zh":"水"},{"_id":"6a5a56019af9f73f38253fe2","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Przewodność elektryczna właściwa Zakres: (10,0 – 2500) µS/cm Metoda konduktometryczna","methodology_en":"Electrical conductivity Range: (10,0 – 2500) µS/cm Conductometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa Zakres: (10,0 – 2500) µS/cm Metoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Przewodność elektryczna właściwa Zakres: (10,0 – 2500) µS/cm Metoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa Zakres: (10,0 – 2500) µS/cm Metoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Electrical conductivity Range: (10,0 – 2500) µS/cm Conductometric method PN-EN 27888:1999","search_zh":"水 PN-EN 27888:1999","test_object_zh":"水"},{"_id":"6a5a56019af9f73f38253fe3","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Mętność Zakres: (0,20 – 100) NTU Metoda nefelometryczna","methodology_en":"Turbidity Range: (0,20 – 100) NTU Nephelometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Mętność Zakres: (0,20 – 100) NTU Metoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Mętność Zakres: (0,20 – 100) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Metnosc Zakres: (0,20 – 100) NTU Metoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Turbidity Range: (0,20 – 100) NTU Nephelometric method PN-EN ISO 7027-1:2016-09","search_zh":"水 浊度 范围：(0,20 – 100) NTU 散射法 PN-EN ISO 7027-1:2016-09","test_object_zh":"水","methodology_zh":"浊度 范围：(0,20 – 100) NTU 散射法"},{"_id":"6a5a56019af9f73f38253fe4","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie żelaza Zakres: (0,030 – 4,000) mg/l Metoda spektrofotometryczna","methodology_en":"Iron concentration Range: (0,030 – 4,000) mg/l Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie żelaza Zakres: (0,030 – 4,000) mg/l Metoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie żelaza Zakres: (0,030 – 4,000) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda Stezenie zelaza Zakres: (0,030 – 4,000) mg/l Metoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Iron concentration Range: (0,030 – 4,000) mg/l Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06","search_zh":"水 PN-ISO 6332:2001+Ap1:2016-06","test_object_zh":"水"},{"_id":"6a5a56019af9f73f38253fe5","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Barwa Zakres: (2 – 100) mg/l Pt Metoda spektrofotometryczna","methodology_en":"Colour Range: (2 – 100) mg/l Pt Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Barwa Zakres: (2 – 100) mg/l Pt Metoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Barwa Zakres: (2 – 100) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06 Woda Barwa Zakres: (2 – 100) mg/l Pt Metoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Colour Range: (2 – 100) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","search_zh":"水 色度 范围：(2 – 100) mg/l Pt 分光光度法 PN-EN ISO 7887:2012 Metoda C +Ap1:2015-06","test_object_zh":"水","methodology_zh":"色度 范围：(2 – 100) mg/l Pt 分光光度法"},{"_id":"6a5a56019af9f73f38253fe6","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba bakterii grupy coli Metoda filtracji membranowej","methodology_en":"Coliform bacteria count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli Metoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda Liczba bakterii grupy coli Metoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠菌群计数 膜过滤法","search_zh":"水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","test_object_zh":"水"},{"_id":"6a5a56019af9f73f38253fe7","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba Escherichia coli Metoda filtracji membranowej","methodology_en":"Escherichia coli count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba Escherichia coli Metoda filtracji membranowej","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba Escherichia coli Metoda filtracji membranowej Woda Liczba Escherichia coli Metoda filtracji membranowej","categories":["water","microbiology"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Escherichia coli count Membrane filtration method","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数 膜过滤法","search_zh":"水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法","test_object_zh":"水"},{"_id":"6a5a56019af9f73f38253fe8","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba enterokoków (paciorkowców kałowych) Metoda filtracji membranowej","methodology_en":"Enterococci (faecal streptococci) count Membrane filtration method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Liczba enterokoków (paciorkowców kałowych) Metoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba enterokoków (paciorkowców kałowych) Metoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Liczba enterokokow (paciorkowcow kalowych) Metoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Enterococci (faecal streptococci) count Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水 肠球菌（粪链球菌）数 膜过滤法 PN-EN ISO 7899-2:2004","test_object_zh":"水","methodology_zh":"肠球菌（粪链球菌）数 膜过滤法"},{"_id":"6a5a56019af9f73f38253fe9","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Ogólna liczba mikroorganizmów w 22°C Metoda płytkowa (posiew wgłębny)","methodology_en":"Total viable count at 22°C Plate method (pour plate)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22°C Metoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ogólna liczba mikroorganizmów w 22°C Metoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w 22°C Metoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水 22°C 微生物总数 平板法（倾注平板） PN-EN ISO 6222:2004","test_object_zh":"水","methodology_zh":"22°C 微生物总数 平板法（倾注平板）"},{"_id":"6a5a56019af9f73f38253fea","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Pobieranie próbek do badań chemicznych, fizycznych, biologicznych i mikrobiologicznych","methodology_en":"Sampling for chemical, physical, biological and microbiological testing","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych, biologicznych i mikrobiologicznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych, fizycznych, biologicznych i mikrobiologicznych PN-EN ISO 5667-13:2011 Osady sciekowe Pobieranie probek do badan chemicznych, fizycznych, biologicznych i mikrobiologicznych PN-EN ISO 5667-13:2011","categories":["water","microbiology"],"row_index":29,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Sampling for chemical, physical, biological and microbiological testing PN-EN ISO 5667-13:2011","search_zh":"污泥 PN-EN ISO 5667-13:2011","test_object_zh":"污泥"},{"_id":"6a5a56019af9f73f38253feb","lab_id":"69ad52a3de79e566650fb518","country":"PL","accr_number":"AB 1012","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Sucha pozostałość Zakres: (1,0 – 99,0) % Metoda wagowa Zawartość wody (z obliczeń)","methodology_en":"Dry residue Range: (1,0 – 99,0) % Gravimetric method Water content (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sucha pozostałość Zakres: (1,0 – 99,0) % Metoda wagowa Zawartość wody (z obliczeń)","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Sucha pozostałość Zakres: (1,0 – 99,0) % Metoda wagowa Zawartość wody (z obliczeń) PN-EN 12880:2004 Osady sciekowe Sucha pozostalosc Zakres: (1,0 – 99,0) % Metoda wagowa Zawartosc wody (z obliczen) PN-EN 12880:2004","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Sewage sludge Dry residue Range: (1,0 – 99,0) % Gravimetric method Water content (calculated) PN-EN 12880:2004","search_zh":"污泥 PN-EN 12880:2004","test_object_zh":"污泥"}],"has_pdf":true}