🇵🇱 GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA PL
Water & wastewaterElectronics & EMCEnvironment
GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA is a laboratory accredited by PCA under number AB 1005 (Warszawa, Poland). Its accreditation scope covers 27 test methods in the following areas: Water & wastewater, Electronics & EMC, Environment. Test objects include: Water Wastewater, Water, Environment - electromagnetic fields in the vicinity of electric po…, Environment – electromagnetic field in the vicinity of radiocommuni….
At a glance
- Accreditation number: PCA AB 1005
- Methods in scope: 27
- Types of test objects: 4
- City: Warszawa, Poland
- Accreditation number
- AB 1005
- Accreditation body
- PCA
- Address
- ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W OPOLU
- City
- Warszawa, Poland
What this laboratory tests (4)
- Water Wastewater — 17 methods
- Water — 5 methods
- Environment - electromagnetic fields in the vicinity of electric power installations — 3 methods
- Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements — 2 methods
Accreditation scope — test methods (27)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Environment - electromagnetic fields in the vicinity of electric power installations | Electric field strength: - in the frequency range 50 Hz Range: (1 – 30000) V/m Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu, z dnia 17 lutego 2020 r. (Dz.U. 2022, poz. 2630) | ||
| 2 | Environment - electromagnetic fields in the vicinity of electric power installations | Magnetic flux density - in the frequency range 50 Hz Range: (1µT – 10mT) Direct measurement method | |||
| 3 | Environment - electromagnetic fields in the vicinity of electric power installations | Magnetic field strength: - in the frequency range 50 Hz (calculated) | |||
| 4 | Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements | Electric field strength: - in the frequency range from 100 MHz to 60 GHz Range: (1,0 – 300) V/m Direct measurement method | Załącznik do Rozporządzenia Ministra Klimatu, z dnia 17 lutego 2020 r. (Dz.U. 2022, poz. 2630) | ||
| 5 | Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements | Magnetic field strength: - in the frequency range from 100 MHz to 60 GHz (calculated) | |||
| 6 | Water Wastewater | Ammonium ion concentration Range: (0,060 – 25) mg/dm3 Ammonium nitrogen concentration Range: (0,050 – 20) mg/dm3 Spectrophotometric method | PN-ISO 7150-1:2002 | ||
| 7 | Water Wastewater | Nitrite concentration Range: (0,016 – 3,28) mg/dm3 Nitrite nitrogen concentration Range: (0,005 – 1,00) mg/dm3 Spectrophotometric method | PN-EN 26777:1999 | ||
| 8 | Water Wastewater | Kjeldahl nitrogen concentration Range: (1,00 – 200) mg/dm3 Titrimetric method | PN-EN 25663:2001 | ||
| 9 | Water Wastewater | Total nitrogen concentration (calculated) | PB-OP-7 wydanie I z dnia 01.07.2022 | ||
| 10 | Water Wastewater | Total phosphorus concentration Range: (0,016 – 7,00) mg/dm3 Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 | ||
| 11 | Water Wastewater | Total phosphorus concentration Range: (0,16 – 80,0) mg/dm3 Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 | ||
| 12 | Water Wastewater | Total suspended solids Range: (4,0 – 500) mg/dm3 Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 13 | Water Wastewater | Chloride concentration Range: (5,00 – 1000) mg/dm3 Titrimetric method | PN-ISO 9297:1994 | ||
| 14 | Water Wastewater | Biochemical oxygen demand - BOD 5 Range: (1,0 – 1000) mg/dm3 O 2 Electrochemical method | PN-EN ISO 5815-1:2019-12 | ||
| 15 | Water Wastewater | Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/dm3 O 2 Electrochemical method | PN-EN 1899-2:2002 | ||
| 16 | Water Wastewater | Chemical oxygen demand - COD-Cr Range: (30 – 1600) mg/dm3 O 2 Titrimetric method | PN-ISO 6060:2006 | ||
| 17 | Water Wastewater | Chemical oxygen demand - COD Range: (10,0 – 1000) mg/dm3 O 2 Spectrophotometric method | PN-ISO 15705:2005 | ||
| 18 | Water Wastewater | Nitrate concentration Range: (0,20 – 100) mg/dm3 Nitrate nitrogen concentration Range: (0,050 – 22) mg/dm3 Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009 | ||
| 19 | Water Wastewater | Total organic carbon concentration Range: (1,00 – 100) mg/dm3 Infrared spectrometry method (IR) | PN-EN 1484:1999 | ||
| 20 | Water Wastewater | Anionic surface-active substances (anionic surfactants) Range: (0,050 – 10,0) mg/dm3 Spectrophotometric method | PN-EN 903:2002 z wyłączeniem pkt. 7.1 | ||
| 21 | Water Wastewater | Dissolved solids Range: (50 – 6000) mg/dm3 Gravimetric method | PN-EN 15216:2022-03 | ||
| 22 | Water Wastewater | Sulphate concentration Range: (3,00 – 500) mg/l Ion chromatography method with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009 | ||
| 23 | Water | Permanganate index Range: (0,50 – 100) mg/dm3 Titrimetric method | PN-EN ISO 8467:2001 | ||
| 24 | Water | Total calcium and magnesium content (total hardness) Range: (22,5 – 800) mg/dm3 Titrimetric method | PN-ISO 6059:1999 | ||
| 25 | Water | Mercury concentration Range: (0,000021 – 0,001000) mg/dm3 Atomic fluorescence spectrometry method | PN-EN ISO 17852:2009 | ||
| 26 | Water | Metal concentrations Range: boron (50,0 – 1000) µg/dm3 arsenic (0,500 – 10,0) µg/dm3 antimony (0,500 – 10,0) µg/dm3 lead (0,300 – 10,0) µg/dm3 nickel (0,500 – 10,0) µg/dm3 cadmium (0,040 – 5,00) µg/dm3 beryllium (0,200 – 5,00) µg/dm3 silver (1,00 – 100) µg/dm3 aluminium (50,0 – 1000) µg/dm3 barium (5,00 – 100) µg/dm3 cobalt (10,0 – 1000) µg/dm3 total chromium (5,00 – 100) µg/dm3 copper (5,00 – 100) µg/dm3 iron (10,0 – 500) µg/dm3 manganese (5,00 – 500) µg/dm3 molybdenum (5,00 – 100) µg/dm3 titanium (1,00 – 50,0) µg/dm3 tin (1,00 – 50,0) µg/dm3 selenium (1,00 – 50,0) µg/dm3 thallium (0,500 – 10,0) µg/dm3 vanadium (5,00 – 100) µg/dm3 zinc (5,00 – 100) µg/dm3 Inductively coupled plasma mass spectrometry (ICP- MS) | PN-EN ISO 17294-2:2024-04 z wyłączeniem pkt. 9.2 | ||
| 27 | Water | Kjeldahl nitrogen concentration Range: (0,25 – 5,0) mg/l spectrophotometric method | PN-EN 25663:2001 | ||
Reference standards (20)
PB-OP-7 wydanie I z dnia 01.07.2022
PN-EN 1484:1999
PN-EN 15216:2022-03
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 872:2007+Ap1:2007
PN-EN 903:2002 z wyłączeniem pkt. 7.1
PN-EN ISO 10304-1:2009
PN-EN ISO 17294-2:2024-04 z wyłączeniem pkt. 9.2
PN-EN ISO 17852:2009
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
PN-EN ISO 8467:2001
PN-ISO 15705:2005
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 7150-1:2002
PN-ISO 9297:1994
Załącznik do Rozporządzenia Ministra Klimatu, z dnia 17 lutego 2020 r. (Dz.U. 2022, poz. 2630)