{"lab":{"_id":"69ad52a3de79e566650fb50e","accr_number":"AB 1005","country":"PL","accr_body":"PCA","address":"ul. Chmielna 132/134, 00-805 Warszawa, CENTRALNE LABORATORIUM BADAWCZE, ODDZIAŁ W OPOLU","categories":["water","environment"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":27,"name":"GŁÓWNY INSPEKTORAT OCHRONY ŚRODOWISKA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_1005.pdf"],"scope_summary":"","search_text":"główny inspektorat ochrony środowiska ul. chmielna 132/134, 00-805 warszawa, centralne laboratorium badawcze, oddział w opolu environment metrology pharma electronics other water materials","status":"active","updated_at":"2026-03-08T14:50:11.082Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:50:11.082Z","parse_date":"2026-07-17T16:19:13.583Z","parse_source":"m5-mistral-qa","email_confidence":"high","email_mx":true,"email_source":"https://www.gov.pl/web/gios/centralne-laboratorium-badawcze","fields_of_testing":[{"codes":"C/28/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków","en":"Chemical tests and sampling of water, sewage"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas, pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors – noise, electromagnetic field)"},{"codes":"N/28/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków","en":"Tests of physical properties and sampling of water, sewage"},{"codes":"N/31/P","pl":"Badania właściwości fizycznych i pobieranie próbek gleby","en":"Tests of physical properties and sampling of soil"}],"issue":{"no":"20","date":"20.11.2025"},"map_coord":[52.227738,20.992749],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":22,"environment":5,"materials":1},"category_scores":{"water":17.29,"environment":0.89,"materials":0.04},"has_zh":true},"methods":[{"_id":"6a5a56019af9f73f38253f24","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Środowisko - pola elektromagnetyczne w otoczeniu instalacji elektroenergetycznych","test_object_en":"Environment - electromagnetic fields in the vicinity of electric power installations","methodology":"Natężenie pola elektrycznego: - w zakresie częstotliwości 50 Hz Zakres: (1 – 30000) V/m Metoda pomiarowa bezpośrednia","methodology_en":"Electric field strength: - in the frequency range 50 Hz Range: (1 – 30000) V/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego: - w zakresie częstotliwości 50 Hz Zakres: (1 – 30000) V/m Metoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu, z dnia 17 lutego 2020 r. (Dz.U. 2022, poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu, z dnia 17 lutego 2020 r. (Dz.U. 2022, poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko - pola elektromagnetyczne w otoczeniu instalacji elektroenergetycznych Natężenie pola elektrycznego: - w zakresie częstotliwości 50 Hz Zakres: (1 – 30000) V/m Metoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu, z dnia 17 lutego 2020 r. (Dz.U. 2022, poz. 2630) Srodowisko - pola elektromagnetyczne w otoczeniu instalacji elektroenergetycznych Natezenie pola elektrycznego: - w zakresie czestotliwosci 50 Hz Zakres: (1 – 30000) V/m Metoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu, z dnia 17 lutego 2020 r. (Dz.U. 2022, poz. 2630)","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment - electromagnetic fields in the vicinity of electric power installations Electric field strength: - in the frequency range 50 Hz Range: (1 – 30000) V/m Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu, z dnia 17 lutego 2020 r. (Dz.U. 2022, poz. 2630)","search_zh":"环境 － 电力设施周围的电磁场 Załącznik do Rozporządzenia Ministra Klimatu, z dnia 17 lutego 2020 r. (Dz.U. 2022, poz. 2630)","test_object_zh":"环境 － 电力设施周围的电磁场"},{"_id":"6a5a56019af9f73f38253f25","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Środowisko - pola elektromagnetyczne w otoczeniu instalacji elektroenergetycznych","test_object_en":"Environment - electromagnetic fields in the vicinity of electric power installations","methodology":"Indukcja magnetyczna - w zakresie częstotliwości 50 Hz Zakres: (1µT – 10mT) Metoda pomiarowa bezpośrednia","methodology_en":"Magnetic flux density - in the frequency range 50 Hz Range: (1µT – 10mT) Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indukcja magnetyczna - w zakresie częstotliwości 50 Hz Zakres: (1µT – 10mT) Metoda pomiarowa bezpośrednia","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko - pola elektromagnetyczne w otoczeniu instalacji elektroenergetycznych Indukcja magnetyczna - w zakresie częstotliwości 50 Hz Zakres: (1µT – 10mT) Metoda pomiarowa bezpośrednia Srodowisko - pola elektromagnetyczne w otoczeniu instalacji elektroenergetycznych Indukcja magnetyczna - w zakresie czestotliwosci 50 Hz Zakres: (1µT – 10mT) Metoda pomiarowa bezposrednia","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment - electromagnetic fields in the vicinity of electric power installations Magnetic flux density - in the frequency range 50 Hz Range: (1µT – 10mT) Direct measurement method","search_zh":"环境 － 电力设施周围的电磁场","test_object_zh":"环境 － 电力设施周围的电磁场"},{"_id":"6a5a56019af9f73f38253f26","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Środowisko - pola elektromagnetyczne w otoczeniu instalacji elektroenergetycznych","test_object_en":"Environment - electromagnetic fields in the vicinity of electric power installations","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości 50 Hz (z obliczeń)","methodology_en":"Magnetic field strength: - in the frequency range 50 Hz (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości 50 Hz (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko - pola elektromagnetyczne w otoczeniu instalacji elektroenergetycznych Natężenie pola magnetycznego: - w zakresie częstotliwości 50 Hz (z obliczeń) Srodowisko - pola elektromagnetyczne w otoczeniu instalacji elektroenergetycznych Natezenie pola magnetycznego: - w zakresie czestotliwosci 50 Hz (z obliczen)","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment - electromagnetic fields in the vicinity of electric power installations Magnetic field strength: - in the frequency range 50 Hz (calculated)","methodology_zh":"磁场强度：－ 频率 50 Hz 范围内（由计算得出）","search_zh":"环境 － 电力设施周围的电磁场 磁场强度：－ 频率 50 Hz 范围内（由计算得出）","test_object_zh":"环境 － 电力设施周围的电磁场"},{"_id":"6a5a56019af9f73f38253f27","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements","methodology":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 MHz do 60 GHz Zakres: (1,0 – 300) V/m Metoda pomiarowa bezpośrednia","methodology_en":"Electric field strength: - in the frequency range from 100 MHz to 60 GHz Range: (1,0 – 300) V/m Direct measurement method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 MHz do 60 GHz Zakres: (1,0 – 300) V/m Metoda pomiarowa bezpośrednia","reference":"Załącznik do Rozporządzenia Ministra Klimatu, z dnia 17 lutego 2020 r. (Dz.U. 2022, poz. 2630)","norm_bases":["Załącznik do Rozporządzenia Ministra Klimatu, z dnia 17 lutego 2020 r. (Dz.U. 2022, poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natężenie pola elektrycznego: - w zakresie częstotliwości od 100 MHz do 60 GHz Zakres: (1,0 – 300) V/m Metoda pomiarowa bezpośrednia Załącznik do Rozporządzenia Ministra Klimatu, z dnia 17 lutego 2020 r. (Dz.U. 2022, poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natezenie pola elektrycznego: - w zakresie czestotliwosci od 100 MHz do 60 GHz Zakres: (1,0 – 300) V/m Metoda pomiarowa bezposrednia Zalacznik do Rozporzadzenia Ministra Klimatu, z dnia 17 lutego 2020 r. (Dz.U. 2022, poz. 2630)","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Electric field strength: - in the frequency range from 100 MHz to 60 GHz Range: (1,0 – 300) V/m Direct measurement method Załącznik do Rozporządzenia Ministra Klimatu, z dnia 17 lutego 2020 r. (Dz.U. 2022, poz. 2630)","search_zh":"环境 — 无线电通信设施周围的电磁场：宽带测量 Załącznik do Rozporządzenia Ministra Klimatu, z dnia 17 lutego 2020 r. (Dz.U. 2022, poz. 2630)","test_object_zh":"环境 — 无线电通信设施周围的电磁场：宽带测量"},{"_id":"6a5a56019af9f73f38253f28","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe","test_object_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements","methodology":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 100 MHz do 60 GHz (z obliczeń)","methodology_en":"Magnetic field strength: - in the frequency range from 100 MHz to 60 GHz (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego: - w zakresie częstotliwości od 100 MHz do 60 GHz (z obliczeń)","reference":"","norm_bases":[],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natężenie pola magnetycznego: - w zakresie częstotliwości od 100 MHz do 60 GHz (z obliczeń) Srodowisko – pole elektromagnetyczne w otoczeniu instalacji radiokomunikacyjnych: pomiary szerokopasmowe Natezenie pola magnetycznego: - w zakresie czestotliwosci od 100 MHz do 60 GHz (z obliczen)","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Environment – electromagnetic field in the vicinity of radiocommunication installations: broadband measurements Magnetic field strength: - in the frequency range from 100 MHz to 60 GHz (calculated)","search_zh":"环境 — 无线电通信设施周围的电磁场：宽带测量","test_object_zh":"环境 — 无线电通信设施周围的电磁场：宽带测量"},{"_id":"6a5a56019af9f73f38253f29","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie jonu amonowego Zakres: (0,060 – 25) mg/dm3 Stężenie azotu amonowego Zakres: (0,050 – 20) mg/dm3 Metoda spektrofotometryczna","methodology_en":"Ammonium ion concentration Range: (0,060 – 25) mg/dm3 Ammonium nitrogen concentration Range: (0,050 – 20) mg/dm3 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego Zakres: (0,060 – 25) mg/dm3 Stężenie azotu amonowego Zakres: (0,050 – 20) mg/dm3 Metoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie jonu amonowego Zakres: (0,060 – 25) mg/dm3 Stężenie azotu amonowego Zakres: (0,050 – 20) mg/dm3 Metoda spektrofotometryczna PN-ISO 7150-1:2002 Woda Scieki Stezenie jonu amonowego Zakres: (0,060 – 25) mg/dm3 Stezenie azotu amonowego Zakres: (0,050 – 20) mg/dm3 Metoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Ammonium ion concentration Range: (0,060 – 25) mg/dm3 Ammonium nitrogen concentration Range: (0,050 – 20) mg/dm3 Spectrophotometric method PN-ISO 7150-1:2002","search_zh":"水 废水 PN-ISO 7150-1:2002","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f2a","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotynów Zakres: (0,016 – 3,28) mg/dm3 Stężenie azotu azotynowego Zakres: (0,005 – 1,00) mg/dm3 Metoda spektrofotometryczna","methodology_en":"Nitrite concentration Range: (0,016 – 3,28) mg/dm3 Nitrite nitrogen concentration Range: (0,005 – 1,00) mg/dm3 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotynów Zakres: (0,016 – 3,28) mg/dm3 Stężenie azotu azotynowego Zakres: (0,005 – 1,00) mg/dm3 Metoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotynów Zakres: (0,016 – 3,28) mg/dm3 Stężenie azotu azotynowego Zakres: (0,005 – 1,00) mg/dm3 Metoda spektrofotometryczna PN-EN 26777:1999 Woda Scieki Stezenie azotynow Zakres: (0,016 – 3,28) mg/dm3 Stezenie azotu azotynowego Zakres: (0,005 – 1,00) mg/dm3 Metoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Nitrite concentration Range: (0,016 – 3,28) mg/dm3 Nitrite nitrogen concentration Range: (0,005 – 1,00) mg/dm3 Spectrophotometric method PN-EN 26777:1999","search_zh":"水 废水 PN-EN 26777:1999","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f2b","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu Kjeldahla Zakres: (1,00 – 200) mg/dm3 Metoda miareczkowa","methodology_en":"Kjeldahl nitrogen concentration Range: (1,00 – 200) mg/dm3 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (1,00 – 200) mg/dm3 Metoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu Kjeldahla Zakres: (1,00 – 200) mg/dm3 Metoda miareczkowa PN-EN 25663:2001 Woda Scieki Stezenie azotu Kjeldahla Zakres: (1,00 – 200) mg/dm3 Metoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Kjeldahl nitrogen concentration Range: (1,00 – 200) mg/dm3 Titrimetric method PN-EN 25663:2001","search_zh":"水 废水 PN-EN 25663:2001","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f2c","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-OP-7 wydanie I z dnia 01.07.2022","norm_bases":["PB-OP-7 wydanie I z dnia 01.07.2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotu ogólnego (z obliczeń) PB-OP-7 wydanie I z dnia 01.07.2022 Woda Scieki Stezenie azotu ogolnego (z obliczen) PB-OP-7 wydanie I z dnia 01.07.2022","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total nitrogen concentration (calculated) PB-OP-7 wydanie I z dnia 01.07.2022","methodology_zh":"总氮浓度（计算值）","search_zh":"水 废水 总氮浓度（计算值） PB-OP-7 wydanie I z dnia 01.07.2022","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f2d","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,016 – 7,00) mg/dm3 Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,016 – 7,00) mg/dm3 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,016 – 7,00) mg/dm3 Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie fosforu ogólnego Zakres: (0,016 – 7,00) mg/dm3 Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 Woda Scieki Stezenie fosforu ogolnego Zakres: (0,016 – 7,00) mg/dm3 Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total phosphorus concentration Range: (0,016 – 7,00) mg/dm3 Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","search_zh":"水 废水 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f2e","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie fosforu ogólnego Zakres: (0,16 – 80,0) mg/dm3 Metoda spektrofotometryczna","methodology_en":"Total phosphorus concentration Range: (0,16 – 80,0) mg/dm3 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego Zakres: (0,16 – 80,0) mg/dm3 Metoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie fosforu ogólnego Zakres: (0,16 – 80,0) mg/dm3 Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 Woda Scieki Stezenie fosforu ogolnego Zakres: (0,16 – 80,0) mg/dm3 Metoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total phosphorus concentration Range: (0,16 – 80,0) mg/dm3 Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","search_zh":"水 废水 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f2f","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Zawiesiny ogólne Zakres: (4,0 – 500) mg/dm3 Metoda wagowa","methodology_en":"Total suspended solids Range: (4,0 – 500) mg/dm3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Zawiesiny ogólne Zakres: (4,0 – 500) mg/dm3 Metoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Zawiesiny ogólne Zakres: (4,0 – 500) mg/dm3 Metoda wagowa PN-EN 872:2007+Ap1:2007 Woda Scieki Zawiesiny ogolne Zakres: (4,0 – 500) mg/dm3 Metoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total suspended solids Range: (4,0 – 500) mg/dm3 Gravimetric method PN-EN 872:2007+Ap1:2007","search_zh":"水 废水 PN-EN 872:2007+Ap1:2007","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f30","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie chlorków Zakres: (5,00 – 1000) mg/dm3 Metoda miareczkowa","methodology_en":"Chloride concentration Range: (5,00 – 1000) mg/dm3 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chlorków Zakres: (5,00 – 1000) mg/dm3 Metoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie chlorków Zakres: (5,00 – 1000) mg/dm3 Metoda miareczkowa PN-ISO 9297:1994 Woda Scieki Stezenie chlorkow Zakres: (5,00 – 1000) mg/dm3 Metoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Chloride concentration Range: (5,00 – 1000) mg/dm3 Titrimetric method PN-ISO 9297:1994","search_zh":"水 废水 PN-ISO 9297:1994","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f31","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 1000) mg/dm3 O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (1,0 – 1000) mg/dm3 O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 1000) mg/dm3 O 2 Metoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 1000) mg/dm3 O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (1,0 – 1000) mg/dm3 O 2 Metoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Biochemical oxygen demand - BOD 5 Range: (1,0 – 1000) mg/dm3 O 2 Electrochemical method PN-EN ISO 5815-1:2019-12","search_zh":"水 废水 PN-EN ISO 5815-1:2019-12","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f32","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/dm3 O 2 Metoda elektrochemiczna","methodology_en":"Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/dm3 O 2 Electrochemical method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/dm3 O 2 Metoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/dm3 O 2 Metoda elektrochemiczna PN-EN 1899-2:2002 Woda Scieki Biochemiczne zapotrzebowanie tlenu - BZT 5 Zakres: (0,5 – 6,0) mg/dm3 O 2 Metoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Biochemical oxygen demand - BOD 5 Range: (0,5 – 6,0) mg/dm3 O 2 Electrochemical method PN-EN 1899-2:2002","search_zh":"水 废水 PN-EN 1899-2:2002","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f33","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (30 – 1600) mg/dm3 O 2 Metoda miareczkowa","methodology_en":"Chemical oxygen demand - COD-Cr Range: (30 – 1600) mg/dm3 O 2 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (30 – 1600) mg/dm3 O 2 Metoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (30 – 1600) mg/dm3 O 2 Metoda miareczkowa PN-ISO 6060:2006 Woda Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr Zakres: (30 – 1600) mg/dm3 O 2 Metoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Chemical oxygen demand - COD-Cr Range: (30 – 1600) mg/dm3 O 2 Titrimetric method PN-ISO 6060:2006","search_zh":"水 废水 PN-ISO 6060:2006","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f34","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (10,0 – 1000) mg/dm3 O 2 Metoda spektrofotometryczna","methodology_en":"Chemical oxygen demand - COD Range: (10,0 – 1000) mg/dm3 O 2 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (10,0 – 1000) mg/dm3 O 2 Metoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (10,0 – 1000) mg/dm3 O 2 Metoda spektrofotometryczna PN-ISO 15705:2005 Woda Scieki Chemiczne zapotrzebowanie tlenu - ChZT Zakres: (10,0 – 1000) mg/dm3 O 2 Metoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Chemical oxygen demand - COD Range: (10,0 – 1000) mg/dm3 O 2 Spectrophotometric method PN-ISO 15705:2005","search_zh":"水 废水 PN-ISO 15705:2005","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f35","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie azotanów Zakres: (0,20 – 100) mg/dm3 Stężenie azotu azotanowego Zakres: (0,050 – 22) mg/dm3 Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Nitrate concentration Range: (0,20 – 100) mg/dm3 Nitrate nitrogen concentration Range: (0,050 – 22) mg/dm3 Ion chromatography with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotanów Zakres: (0,20 – 100) mg/dm3 Stężenie azotu azotanowego Zakres: (0,050 – 22) mg/dm3 Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009","norm_bases":["PN-EN ISO 10304-1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie azotanów Zakres: (0,20 – 100) mg/dm3 Stężenie azotu azotanowego Zakres: (0,050 – 22) mg/dm3 Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 Woda Scieki Stezenie azotanow Zakres: (0,20 – 100) mg/dm3 Stezenie azotu azotanowego Zakres: (0,050 – 22) mg/dm3 Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Nitrate concentration Range: (0,20 – 100) mg/dm3 Nitrate nitrogen concentration Range: (0,050 – 22) mg/dm3 Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009","search_zh":"水 废水 PN-EN ISO 10304-1:2009","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f36","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie ogólnego węgla organicznego Zakres: (1,00 – 100) mg/dm3 Metoda spektrometrii w podczerwieni (IR)","methodology_en":"Total organic carbon concentration Range: (1,00 – 100) mg/dm3 Infrared spectrometry method (IR)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego Zakres: (1,00 – 100) mg/dm3 Metoda spektrometrii w podczerwieni (IR)","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie ogólnego węgla organicznego Zakres: (1,00 – 100) mg/dm3 Metoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999 Woda Scieki Stezenie ogolnego wegla organicznego Zakres: (1,00 – 100) mg/dm3 Metoda spektrometrii w podczerwieni (IR) PN-EN 1484:1999","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Total organic carbon concentration Range: (1,00 – 100) mg/dm3 Infrared spectrometry method (IR) PN-EN 1484:1999","search_zh":"水 废水 PN-EN 1484:1999","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f37","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Substancje powierzchniowo czynne anionowe (surfaktanty anionowe) Zakres: (0,050 – 10,0) mg/dm3 Metoda spektrofotometryczna","methodology_en":"Anionic surface-active substances (anionic surfactants) Range: (0,050 – 10,0) mg/dm3 Spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Substancje powierzchniowo czynne anionowe (surfaktanty anionowe) Zakres: (0,050 – 10,0) mg/dm3 Metoda spektrofotometryczna","reference":"PN-EN 903:2002 z wyłączeniem pkt. 7.1","norm_bases":["PN-EN 903:2002 z wyłączeniem pkt. 7.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Substancje powierzchniowo czynne anionowe (surfaktanty anionowe) Zakres: (0,050 – 10,0) mg/dm3 Metoda spektrofotometryczna PN-EN 903:2002 z wyłączeniem pkt. 7.1 Woda Scieki Substancje powierzchniowo czynne anionowe (surfaktanty anionowe) Zakres: (0,050 – 10,0) mg/dm3 Metoda spektrofotometryczna PN-EN 903:2002 z wylaczeniem pkt. 7.1","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Anionic surface-active substances (anionic surfactants) Range: (0,050 – 10,0) mg/dm3 Spectrophotometric method PN-EN 903:2002 z wyłączeniem pkt. 7.1","search_zh":"水 废水 PN-EN 903:2002 z wyłączeniem pkt. 7.1","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f38","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Substancje rozpuszczone Zakres: (50 – 6000) mg/dm3 Metoda wagowa","methodology_en":"Dissolved solids Range: (50 – 6000) mg/dm3 Gravimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Substancje rozpuszczone Zakres: (50 – 6000) mg/dm3 Metoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Substancje rozpuszczone Zakres: (50 – 6000) mg/dm3 Metoda wagowa PN-EN 15216:2022-03 Woda Scieki Substancje rozpuszczone Zakres: (50 – 6000) mg/dm3 Metoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Dissolved solids Range: (50 – 6000) mg/dm3 Gravimetric method PN-EN 15216:2022-03","search_zh":"水 废水 PN-EN 15216:2022-03","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f39","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda Ścieki","test_object_en":"Water Wastewater","methodology":"Stężenie siarczanów Zakres: (3,00 – 500) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","methodology_en":"Sulphate concentration Range: (3,00 – 500) mg/l Ion chromatography method with conductometric detection (IC-CD)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie siarczanów Zakres: (3,00 – 500) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009","norm_bases":["PN-EN ISO 10304-1:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ścieki Stężenie siarczanów Zakres: (3,00 – 500) mg/l Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 Woda Scieki Stezenie siarczanow Zakres: (3,00 – 500) mg/l Metoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Wastewater Sulphate concentration Range: (3,00 – 500) mg/l Ion chromatography method with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009","search_zh":"水 废水 PN-EN ISO 10304-1:2009","test_object_zh":"水 废水"},{"_id":"6a5a56019af9f73f38253f3a","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Indeks nadmanganianowy Zakres: (0,50 – 100) mg/dm3 Metoda miareczkowa","methodology_en":"Permanganate index Range: (0,50 – 100) mg/dm3 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy Zakres: (0,50 – 100) mg/dm3 Metoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Indeks nadmanganianowy Zakres: (0,50 – 100) mg/dm3 Metoda miareczkowa PN-EN ISO 8467:2001 Woda Indeks nadmanganianowy Zakres: (0,50 – 100) mg/dm3 Metoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Permanganate index Range: (0,50 – 100) mg/dm3 Titrimetric method PN-EN ISO 8467:2001","search_zh":"水 PN-EN ISO 8467:2001","test_object_zh":"水"},{"_id":"6a5a56019af9f73f38253f3b","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (22,5 – 800) mg/dm3 Metoda miareczkowa","methodology_en":"Total calcium and magnesium content (total hardness) Range: (22,5 – 800) mg/dm3 Titrimetric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (22,5 – 800) mg/dm3 Metoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna) Zakres: (22,5 – 800) mg/dm3 Metoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna) Zakres: (22,5 – 800) mg/dm3 Metoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Total calcium and magnesium content (total hardness) Range: (22,5 – 800) mg/dm3 Titrimetric method PN-ISO 6059:1999","search_zh":"水 PN-ISO 6059:1999","test_object_zh":"水"},{"_id":"6a5a56019af9f73f38253f3c","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie rtęci Zakres: (0,000021 – 0,001000) mg/dm3 Metoda atomowej spektrometrii fluorescencyjnej","methodology_en":"Mercury concentration Range: (0,000021 – 0,001000) mg/dm3 Atomic fluorescence spectrometry method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie rtęci Zakres: (0,000021 – 0,001000) mg/dm3 Metoda atomowej spektrometrii fluorescencyjnej","reference":"PN-EN ISO 17852:2009","norm_bases":["PN-EN ISO 17852:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie rtęci Zakres: (0,000021 – 0,001000) mg/dm3 Metoda atomowej spektrometrii fluorescencyjnej PN-EN ISO 17852:2009 Woda Stezenie rteci Zakres: (0,000021 – 0,001000) mg/dm3 Metoda atomowej spektrometrii fluorescencyjnej PN-EN ISO 17852:2009","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Mercury concentration Range: (0,000021 – 0,001000) mg/dm3 Atomic fluorescence spectrometry method PN-EN ISO 17852:2009","search_zh":"水 PN-EN ISO 17852:2009","test_object_zh":"水"},{"_id":"6a5a56019af9f73f38253f3d","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie metali Zakres: bor (50,0 – 1000) µg/dm3 arsen (0,500 – 10,0) µg/dm3 antymon (0,500 – 10,0) µg/dm3 ołów (0,300 – 10,0) µg/dm3 nikiel (0,500 – 10,0) µg/dm3 kadm (0,040 – 5,00) µg/dm3 beryl (0,200 – 5,00) µg/dm3 srebro (1,00 – 100) µg/dm3 glin (50,0 – 1000) µg/dm3 bar (5,00 – 100) µg/dm3 kobalt (10,0 – 1000) µg/dm3 chrom ogólny (5,00 – 100) µg/dm3 miedź (5,00 – 100) µg/dm3 żelazo (10,0 – 500) µg/dm3 mangan (5,00 – 500) µg/dm3 molibden (5,00 – 100) µg/dm3 tytan (1,00 – 50,0) µg/dm3 cyna (1,00 – 50,0) µg/dm3 selen (1,00 – 50,0) µg/dm3 tal (0,500 – 10,0) µg/dm3 wanad (5,00 – 100) µg/dm3 cynk (5,00 – 100) µg/dm3 Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP- MS)","methodology_en":"Metal concentrations Range: boron (50,0 – 1000) µg/dm3 arsenic (0,500 – 10,0) µg/dm3 antimony (0,500 – 10,0) µg/dm3 lead (0,300 – 10,0) µg/dm3 nickel (0,500 – 10,0) µg/dm3 cadmium (0,040 – 5,00) µg/dm3 beryllium (0,200 – 5,00) µg/dm3 silver (1,00 – 100) µg/dm3 aluminium (50,0 – 1000) µg/dm3 barium (5,00 – 100) µg/dm3 cobalt (10,0 – 1000) µg/dm3 total chromium (5,00 – 100) µg/dm3 copper (5,00 – 100) µg/dm3 iron (10,0 – 500) µg/dm3 manganese (5,00 – 500) µg/dm3 molybdenum (5,00 – 100) µg/dm3 titanium (1,00 – 50,0) µg/dm3 tin (1,00 – 50,0) µg/dm3 selenium (1,00 – 50,0) µg/dm3 thallium (0,500 – 10,0) µg/dm3 vanadium (5,00 – 100) µg/dm3 zinc (5,00 – 100) µg/dm3 Inductively coupled plasma mass spectrometry (ICP- MS)","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie metali Zakres: bor (50,0 – 1000) µg/dm3 arsen (0,500 – 10,0) µg/dm3 antymon (0,500 – 10,0) µg/dm3 ołów (0,300 – 10,0) µg/dm3 nikiel (0,500 – 10,0) µg/dm3 kadm (0,040 – 5,00) µg/dm3 beryl (0,200 – 5,00) µg/dm3 srebro (1,00 – 100) µg/dm3 glin (50,0 – 1000) µg/dm3 bar (5,00 – 100) µg/dm3 kobalt (10,0 – 1000) µg/dm3 chrom ogólny (5,00 – 100) µg/dm3 miedź (5,00 – 100) µg/dm3 żelazo (10,0 – 500) µg/dm3 mangan (5,00 – 500) µg/dm3 molibden (5,00 – 100) µg/dm3 tytan (1,00 – 50,0) µg/dm3 cyna (1,00 – 50,0) µg/dm3 selen (1,00 – 50,0) µg/dm3 tal (0,500 – 10,0) µg/dm3 wanad (5,00 – 100) µg/dm3 cynk (5,00 – 100) µg/dm3 Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP- MS)","reference":"PN-EN ISO 17294-2:2024-04 z wyłączeniem pkt. 9.2","norm_bases":["PN-EN ISO 17294-2:2024-04 z wyłączeniem pkt. 9.2"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie metali Zakres: bor (50,0 – 1000) µg/dm3 arsen (0,500 – 10,0) µg/dm3 antymon (0,500 – 10,0) µg/dm3 ołów (0,300 – 10,0) µg/dm3 nikiel (0,500 – 10,0) µg/dm3 kadm (0,040 – 5,00) µg/dm3 beryl (0,200 – 5,00) µg/dm3 srebro (1,00 – 100) µg/dm3 glin (50,0 – 1000) µg/dm3 bar (5,00 – 100) µg/dm3 kobalt (10,0 – 1000) µg/dm3 chrom ogólny (5,00 – 100) µg/dm3 miedź (5,00 – 100) µg/dm3 żelazo (10,0 – 500) µg/dm3 mangan (5,00 – 500) µg/dm3 molibden (5,00 – 100) µg/dm3 tytan (1,00 – 50,0) µg/dm3 cyna (1,00 – 50,0) µg/dm3 selen (1,00 – 50,0) µg/dm3 tal (0,500 – 10,0) µg/dm3 wanad (5,00 – 100) µg/dm3 cynk (5,00 – 100) µg/dm3 Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP- MS) PN-EN ISO 17294-2:2024-04 z wyłączeniem pkt. 9.2 Woda Stezenie metali Zakres: bor (50,0 – 1000) µg/dm3 arsen (0,500 – 10,0) µg/dm3 antymon (0,500 – 10,0) µg/dm3 olow (0,300 – 10,0) µg/dm3 nikiel (0,500 – 10,0) µg/dm3 kadm (0,040 – 5,00) µg/dm3 beryl (0,200 – 5,00) µg/dm3 srebro (1,00 – 100) µg/dm3 glin (50,0 – 1000) µg/dm3 bar (5,00 – 100) µg/dm3 kobalt (10,0 – 1000) µg/dm3 chrom ogolny (5,00 – 100) µg/dm3 miedz (5,00 – 100) µg/dm3 zelazo (10,0 – 500) µg/dm3 mangan (5,00 – 500) µg/dm3 molibden (5,00 – 100) µg/dm3 tytan (1,00 – 50,0) µg/dm3 cyna (1,00 – 50,0) µg/dm3 selen (1,00 – 50,0) µg/dm3 tal (0,500 – 10,0) µg/dm3 wanad (5,00 – 100) µg/dm3 cynk (5,00 – 100) µg/dm3 Metoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP- MS) PN-EN ISO 17294-2:2024-04 z wylaczeniem pkt. 9.2","categories":["materials","water"],"row_index":25,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Metal concentrations Range: boron (50,0 – 1000) µg/dm3 arsenic (0,500 – 10,0) µg/dm3 antimony (0,500 – 10,0) µg/dm3 lead (0,300 – 10,0) µg/dm3 nickel (0,500 – 10,0) µg/dm3 cadmium (0,040 – 5,00) µg/dm3 beryllium (0,200 – 5,00) µg/dm3 silver (1,00 – 100) µg/dm3 aluminium (50,0 – 1000) µg/dm3 barium (5,00 – 100) µg/dm3 cobalt (10,0 – 1000) µg/dm3 total chromium (5,00 – 100) µg/dm3 copper (5,00 – 100) µg/dm3 iron (10,0 – 500) µg/dm3 manganese (5,00 – 500) µg/dm3 molybdenum (5,00 – 100) µg/dm3 titanium (1,00 – 50,0) µg/dm3 tin (1,00 – 50,0) µg/dm3 selenium (1,00 – 50,0) µg/dm3 thallium (0,500 – 10,0) µg/dm3 vanadium (5,00 – 100) µg/dm3 zinc (5,00 – 100) µg/dm3 Inductively coupled plasma mass spectrometry (ICP- MS) PN-EN ISO 17294-2:2024-04 z wyłączeniem pkt. 9.2","search_zh":"水 PN-EN ISO 17294-2:2024-04 z wyłączeniem pkt. 9.2","test_object_zh":"水"},{"_id":"6a5a56019af9f73f38253f3e","lab_id":"69ad52a3de79e566650fb50e","country":"PL","accr_number":"AB 1005","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotu Kjeldahla Zakres: (0,25 – 5,0) mg/l metoda spektrofotometryczna","methodology_en":"Kjeldahl nitrogen concentration Range: (0,25 – 5,0) mg/l spectrophotometric method","parameters":[],"parameters_en":[],"technique":null,"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla Zakres: (0,25 – 5,0) mg/l metoda spektrofotometryczna","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotu Kjeldahla Zakres: (0,25 – 5,0) mg/l metoda spektrofotometryczna PN-EN 25663:2001 Woda Stezenie azotu Kjeldahla Zakres: (0,25 – 5,0) mg/l metoda spektrofotometryczna PN-EN 25663:2001","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"m5-mistral-qa","search_en":"Water Kjeldahl nitrogen concentration Range: (0,25 – 5,0) mg/l spectrophotometric method PN-EN 25663:2001","search_zh":"水 PN-EN 25663:2001","test_object_zh":"水"}],"has_pdf":true}