🇵🇱 INSTYTUT ENERGETYKI – PAŃSTWOWY INSTYTUT BADAWCZY PL
Petrochemistry & fuelsWater & wastewaterEnvironment
INSTYTUT ENERGETYKI – PAŃSTWOWY INSTYTUT BADAWCZY is a laboratory accredited by PCA under number AB 087 (Łódź, Poland). Its accreditation scope covers 491 test methods in the following areas: Petrochemistry & fuels, Water & wastewater, Environment. Test objects include: HEATING BOILERS FOR SOLID FUELS, RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS, RESIDENTIAL SOLID FUEL BURNING APPLIANCES, RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPL…. Most frequently used techniques: Chemiluminescence method (CLD); Continuous flame ionization detecti…, Gravimetric method, Non-dispersive infrared spectrometry (NDIR).
At a glance
- Accreditation number: PCA AB 087
- Methods in scope: 491
- Types of test objects: 19
- Techniques used: 5
- City: Łódź, Poland
- Accreditation number
- AB 087
- Accreditation body
- PCA
- Address
- ul. Mory 8, 01-330 Warszawa, LABORATORIUM BADAŃ KOTŁÓW I URZĄDZEŃ GRZEWCZYCH, ul. Dostawcza 1, 93-231 Łódź
- City
- Łódź, Poland
What this laboratory tests (19)
- HEATING BOILERS FOR SOLID FUELS — 47 methods
- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS — 41 methods
- RESIDENTIAL SOLID FUEL BURNING APPLIANCES — 40 methods
- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING — 40 methods
- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS — 39 methods
- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS — 37 methods
- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES — 36 methods
- PELLET-FIRED LOCAL SPACE HEATERS — 31 methods
- SOLID FUEL COOKERS — 30 methods
- SOLID FUEL FIREPLACE INSERTS — 28 methods
- SOLID FUEL LOCAL SPACE HEATERS — 28 methods
- HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW — 27 methods
- SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS — 24 methods
- RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES — 23 methods
- - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES — 16 methods
- and 4 more
Analytical techniques used (5)
- Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) — 14 methods
- Gravimetric method — 14 methods
- Non-dispersive infrared spectrometry (NDIR) — 14 methods
- Power transducer method — 4 methods
- Method: power transducers — 1 method
Laboratory locations
- LABORATORIUM BADAŃ KOTŁÓW I URZĄDZEŃ GRZEWCZYCH — ul. Dostawcza 1
Accreditation scope — test methods (491)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Boiler and Heating Equipment Testing Laboratory | |||||
| 1 | HEATING BOILERS FOR SOLID FUELS | WATER PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
|||
| 2 | HEATING BOILERS FOR SOLID FUELS | temperature (0 - 100) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p.5.2; 5.7.2; 5.7.3; 5.8.2 | PN-EN 303-5:2021-09 p.5.2; 5.6.2; 5.6.3; 5.7.2; 5.7.3 | PN-EN 303-5+A1:2023-05 p. 5.2, 5.6.2, 5.6.3, 5.7.2, 5,7,3 | PN-M-34452:1999 p. 4.3.6 | ||
| 3 | HEATING BOILERS FOR SOLID FUELS | pressure (0 - 0,6) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2 | PN-M-34452:1999 p. 5.3.7 | ||
| 4 | HEATING BOILERS FOR SOLID FUELS | mass flow rate (0 - 80000) kg/h (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2 | PN-M-34452:1999 p. 4.3.2 | ||
| 5 | HEATING BOILERS FOR SOLID FUELS | volume flow rate (0 - 80) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2 | ||
| 6 | HEATING BOILERS FOR SOLID FUELS | FUEL PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2 | ||
| 7 | HEATING BOILERS FOR SOLID FUELS | moisture content in wood Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Procedura nr LGP/42/B wyd. 4 | ||
| 8 | HEATING BOILERS FOR SOLID FUELS | mass flow rate (0 - 1000) kg/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p. 5.2, 5.7.3, 5.7.4 | PN-EN 303-5:2021-09 p. 5.2; 5.6.3; 5.6.4 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.3; 5.6.4 | PN-M-34452:1999 p. 4.3.3 | ||
| 9 | HEATING BOILERS FOR SOLID FUELS | net calorific value (10 - 32) MJ/kg (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Procedura nr LGP/42/B wyd. 4 | ||
| 10 | HEATING BOILERS FOR SOLID FUELS | FURNACE WASTE: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Procedura nr LGP/42/B wyd. 4 | ||
| 11 | HEATING BOILERS FOR SOLID FUELS | ash mass flow rate (0 - 300) kg/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-M-34452:1999 p. 4.3.3 | ||
| 12 | HEATING BOILERS FOR SOLID FUELS | slag mass flow rate (0 - 300) kg/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-M-34452:1999 p. 4.3.3 | ||
| 13 | HEATING BOILERS FOR SOLID FUELS | FLUE GAS PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-M-34452:1999 p. 4.3.3 | ||
| 14 | HEATING BOILERS FOR SOLID FUELS | temperature (0 - 600) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p. 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.3 | PN-EN 304:2017-11 rys.4,5,6 | PN-M-34452:1999 p. 4.3.6.3 | ||
| 15 | HEATING BOILERS FOR SOLID FUELS | pressure (-10 - 10) hPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p. 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.3 | PN-EN 304:2017-11 rys.4,5,6 | PN-M-34452:1999 p. 4.3.6.3 | ||
| 16 | HEATING BOILERS FOR SOLID FUELS | Concentrations of carbon dioxide, carbon monoxide. CO2; (0,5 - 16) % CO; (0,0003 - 4,0) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | |
| 17 | HEATING BOILERS FOR SOLID FUELS | Concentrations of nitrogen monoxide, OGC. NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) | PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | |
| 18 | HEATING BOILERS FOR SOLID FUELS | Dust concentration in flue gases Range (0,002 - 1) g/m3 Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Gravimetric method | PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-M–34452:1999 p. 4.3.8; 4.4.3.12 | |
| 19 | HEATING BOILERS FOR SOLID FUELS | AMBIENT AIR PARAMETERS AT THE TEST SITE: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-M–34452:1999 p. 4.3.8; 4.4.3.12 | ||
| 20 | HEATING BOILERS FOR SOLID FUELS | temperature (10-35)°C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p. 5.7.1; 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.1; 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.3 | PN-M–34452:1999 p. 4.2.7 | ||
| 21 | HEATING BOILERS FOR SOLID FUELS | pressure (940-1060) hPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 297:2002 p. 4.1.6.7 | ||
| 22 | HEATING BOILERS FOR SOLID FUELS | HEAT BALANCE (calculated): Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 297:2002 p. 4.1.6.7 | ||
| 23 | HEATING BOILERS FOR SOLID FUELS | heat output (1,5 - 1000) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.8.1.1; 5.8.1.2; 5.8.2; 5.8.3; 5.10.1 | PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.7.1.1; 5.7.1.2; 5.7.2; 5.7.3; 5.9.1 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.7.1.1, 5.7.1.2, 5.7.2, 5.7.3, 5.9.1 | PN-M-34452:1999 p.4.4.3.1;4.4.3.18;5.3 | ||
| 24 | HEATING BOILERS FOR SOLID FUELS | heat input from fuel (1,7 - 2000) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.10.2 | PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.9.2 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.9.2 | PN-M–34452:1999 p. 5.2 | ||
| 25 | HEATING BOILERS FOR SOLID FUELS | verification of the nominal heat output in condensing mode Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5 +A1:2023-05 p. 5.7.4 | ||
| 26 | HEATING BOILERS FOR SOLID FUELS | verification of the minimum heat output in condensing mode Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5 +A1:2023-05 p. 5.7.5 | ||
| 27 | HEATING BOILERS FOR SOLID FUELS | sampling and verification of the condensate composition Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5 +A1:2023-05 p. 5.12 | ||
| 28 | HEATING BOILERS FOR SOLID FUELS | safety of the condensation process Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5 +A1:2023-05 p. 5.17 | ||
| 29 | HEATING BOILERS FOR SOLID FUELS | Efficiency (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 5.4 | ||
| 30 | HEATING BOILERS FOR SOLID FUELS | stack loss (5-40) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p. 5.10.3.2 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 4.4.3.3; 5.6.1 | ||
| 31 | HEATING BOILERS FOR SOLID FUELS | losses due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 4.4.3.4; 5.6.2 | ||
| 32 | HEATING BOILERS FOR SOLID FUELS | loss due to incomplete combustion (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p.5.10.3 | PN-M–34452:1999 p. 4.4.3.5; 5.6.3 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | ||
| 33 | HEATING BOILERS FOR SOLID FUELS | losses to the surroundings Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 304:2017-11 p. A.8.3 | PN-M–34452:1999 p. 4.4.3.6; 5.6.4 | PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | ||
| 34 | HEATING BOILERS FOR SOLID FUELS | TECHNICAL AND OPERATIONAL PARAMETERS OF THE BOILER: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 304:2017-11 p. A.8.3 | PN-M–34452:1999 p. 4.4.3.6; 5.6.4 | PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | ||
| 35 | HEATING BOILERS FOR SOLID FUELS | water flow resistance water pressure (10-2000) Pa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p.5.11 | PN-EN 303-5:2021-09 p.5.10 | PN-EN 303-5+A1:2023-05 p. 5.10 | PN-EN 304:2017-11 p. 6.6 | ||
| 36 | HEATING BOILERS FOR SOLID FUELS | temperatures of external surfaces (0-200) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.11 | PN-EN 303-5+A1:2023-05 p. 5.11 | PN-M–34452:1999 p. 4.4.3.16 | ||
| 37 | HEATING BOILERS FOR SOLID FUELS | temperatures of handles (0-200) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.11 | PN-EN 303-5+A1:2023-05 p. 5.11 | PN-M–34452:1999 p. 4.4.3.16 | ||
| 38 | HEATING BOILERS FOR SOLID FUELS | temperature of the floor under the boiler (0-200) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-M–34452:1999 p. 4.4.3.16 | PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.12 | PN-EN 303-5+A1:2023-05 p. 5.12 | PN-EN 304:2017-11 p. 6.15 | ||
| 39 | HEATING BOILERS FOR SOLID FUELS | leak-tightness testing Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p. 5.6 | PN-EN 303-5:2021-09 p. 5.16.6, 5.18.1 | PN-EN 303-5 +A1:2023-05 p. 5.16.6, 5.18.1 | ||
| 40 | HEATING BOILERS FOR SOLID FUELS | OPERATION OF AUTOMATIC CONTROLS AND SAFETY DEVICES: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p. 5.6 | PN-EN 303-5:2021-09 p. 5.16.6, 5.18.1 | PN-EN 303-5 +A1:2023-05 p. 5.16.6, 5.18.1 | ||
| 41 | HEATING BOILERS FOR SOLID FUELS | operation of the water temperature controller and the safety temperature limiter (0-110)°C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p. 5.13 | PN-EN 303-5:2021-09 p.5.13 | PN-EN 303-5+A1:2023-05 p. 5.13 | ||
| 42 | HEATING BOILERS FOR SOLID FUELS | operation of the excess heat discharge device water temperature (0-120) °C water pressure (0,1-0,3) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p. 5.15 | PN-EN 303-5:2021-09 p. 5.15 | PN-EN 303-5+A1:2023-05 p. 5.15 | ||
| 43 | HEATING BOILERS FOR SOLID FUELS | operation of fast switch-off systems Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2012 p. 5.14 | PN-EN 303-5 +A1:2023-05 p. 5.14 | ||
| 44 | HEATING BOILERS FOR SOLID FUELS | safety of boilers under fuel overfilling conditions and when the fuel feed is blocked Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2021-09 p. 5.16.2 | PN-EN 303-5 +A1:2023-05 p. 5.16.2 | ||
| 45 | HEATING BOILERS FOR SOLID FUELS | safety of boilers in the event of air supply failure Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2021-09 p. 5.16.3 | PN-EN 303-5 +A1:2023-05 p. 5.16.3 | ||
| 46 | HEATING BOILERS FOR SOLID FUELS | safety of boilers with respect to heat conduction Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2021-09 p. 5.16.4 | PN-EN 303-5 +A1:2023-05 p. 5.16.4 | ||
| 47 | SOLID FUEL LOCAL SPACE HEATERS | FUEL PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2021-09 p. 5.16.4 | PN-EN 303-5 +A1:2023-05 p. 5.16.4 | ||
| 48 | SOLID FUEL LOCAL SPACE HEATERS | moisture content in wood (10-50) % net calorific value (10-32) MJ/kg (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Procedura nr LGP/42/B wyd. 4 | ||
| 49 | SOLID FUEL LOCAL SPACE HEATERS | fuel mass (0,1-300) kg Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.4.2 | ||
| 50 | SOLID FUEL LOCAL SPACE HEATERS | FLUE GAS PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.4.2 | ||
| 51 | SOLID FUEL LOCAL SPACE HEATERS | temperature (15-1100) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.4.4.3 | ||
| 52 | SOLID FUEL LOCAL SPACE HEATERS | pressure (-10 - 10) hPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A2.3.4; A.4 | ||
| 53 | SOLID FUEL LOCAL SPACE HEATERS | Concentrations of carbon dioxide, carbon monoxide. CO2; (0,5-16) % CO; (0,0003-4,0) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 13240:2008 p. A.4.4.2 | |
| 54 | SOLID FUEL LOCAL SPACE HEATERS | Concentrations of nitrogen monoxide, OGC. NO; (5 - 440) mg/m3 OGC; (3,5-1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | |
| 55 | SOLID FUEL LOCAL SPACE HEATERS | dust concentration in flue gases (0,002-1) g/m3 Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Gravimetric method | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 | |
| 56 | SOLID FUEL LOCAL SPACE HEATERS | AIR PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 | ||
| 57 | SOLID FUEL LOCAL SPACE HEATERS | temperature (10 - 35) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.4.4.3 | ||
| 58 | SOLID FUEL LOCAL SPACE HEATERS | WATER PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.4.4.3 | ||
| 59 | SOLID FUEL LOCAL SPACE HEATERS | temperature (10 - 100)°C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.4.5.2 | ||
| 60 | SOLID FUEL LOCAL SPACE HEATERS | volume flow rate (0 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.4.5.2 | ||
| 61 | SOLID FUEL LOCAL SPACE HEATERS | HEAT BALANCE (calculated): Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.4.5.2 | ||
| 62 | SOLID FUEL LOCAL SPACE HEATERS | heat input from fuel (3 - 60) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.6.2.2 | ||
| 63 | SOLID FUEL LOCAL SPACE HEATERS | stack loss (5 - 40) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.6.2.1.1 | ||
| 64 | SOLID FUEL LOCAL SPACE HEATERS | losses due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.6.2.1.2 | ||
| 65 | SOLID FUEL LOCAL SPACE HEATERS | loss due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.6.2.1.3 | ||
| 66 | SOLID FUEL LOCAL SPACE HEATERS | thermal efficiency (20 - 95) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.6.2.1 | ||
| 67 | SOLID FUEL LOCAL SPACE HEATERS | total heat output (3 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.6.2.2 | ||
| 68 | SOLID FUEL LOCAL SPACE HEATERS | heat output of the water circuit (3 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.6.2.3 | ||
| 69 | SOLID FUEL LOCAL SPACE HEATERS | heat output to the room (3 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.6.2.4 | ||
| 70 | SOLID FUEL LOCAL SPACE HEATERS | CO content (O2=13%) (0 - 4)% Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.6.2.6 | ||
| 71 | SOLID FUEL LOCAL SPACE HEATERS | TECHNICAL AND OPERATIONAL PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.6.2.6 | ||
| 72 | SOLID FUEL LOCAL SPACE HEATERS | temperature of the measuring corner and the floor (0 - 200) °C temperature of the fuel hopper (0 - 200) °C temperature of handles (0 - 200) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.4.7; A.4.8; A.4.9 | ||
| 73 | SOLID FUEL LOCAL SPACE HEATERS | tightness of the water space (0,1 - 0,6) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.4.9.4 | ||
| 74 | SOLID FUEL LOCAL SPACE HEATERS | thermal outlet safety device water temperature (0 - 120) °C water pressure (0,1 - 0,3) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.4.9.5 | ||
| 75 | SOLID FUEL FIREPLACE INSERTS | FUEL PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13240:2008 p. A.4.9.5 | ||
| 76 | SOLID FUEL FIREPLACE INSERTS | moisture content in wood ( 10 - 50) % net calorific value (10 - 32) MJ/kg (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Procedura nr LGP/42/B wyd. 4 | ||
| 77 | SOLID FUEL FIREPLACE INSERTS | fuel mass (0,1 - 300) kg Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.4.2 | ||
| 78 | SOLID FUEL FIREPLACE INSERTS | FLUE GAS PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.4.2 | ||
| 79 | SOLID FUEL FIREPLACE INSERTS | temperature (0 - 600) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.4.4.3 | ||
| 80 | SOLID FUEL FIREPLACE INSERTS | pressure (-10 - 10) hPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A2.3.4;A.4 | ||
| 81 | SOLID FUEL FIREPLACE INSERTS | Concentrations of carbon dioxide, carbon monoxide. CO2; (0,5 - 16) % CO; (0,0003 - 4,0) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 13229:2002 p. A.4.4.2 | |
| 82 | SOLID FUEL FIREPLACE INSERTS | Concentrations of nitrogen monoxide, OGC. NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | |
| 83 | SOLID FUEL FIREPLACE INSERTS | Dust concentration in flue gases Range (0,002 - 1) g/m3 Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Gravimetric method | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 | |
| 84 | SOLID FUEL FIREPLACE INSERTS | AIR PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 | ||
| 85 | SOLID FUEL FIREPLACE INSERTS | temperature (10 - 35) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.4.4.3 | ||
| 86 | SOLID FUEL FIREPLACE INSERTS | WATER PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.4.4.3 | ||
| 87 | SOLID FUEL FIREPLACE INSERTS | temperature (0 - 100) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.4.5.2 | ||
| 88 | SOLID FUEL FIREPLACE INSERTS | volume flow rate (0 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.4.5.2 | ||
| 89 | SOLID FUEL FIREPLACE INSERTS | HEAT BALANCE (calculated): Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.4.5.2 | ||
| 90 | SOLID FUEL FIREPLACE INSERTS | heat input from fuel (3 - 60) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.6.2.2 | ||
| 91 | SOLID FUEL FIREPLACE INSERTS | stack loss (5 - 40) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.6.2.1.1 | ||
| 92 | SOLID FUEL FIREPLACE INSERTS | losses due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.6.2.1.2 | ||
| 93 | SOLID FUEL FIREPLACE INSERTS | loss due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.6.2.1.3 | ||
| 94 | SOLID FUEL FIREPLACE INSERTS | thermal efficiency (20 - 95) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.6.2.1 | ||
| 95 | SOLID FUEL FIREPLACE INSERTS | total heat output (3 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.6.2.2 | ||
| 96 | SOLID FUEL FIREPLACE INSERTS | heat output of the water circuit (0 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.6.2.3 | ||
| 97 | SOLID FUEL FIREPLACE INSERTS | heat output to the room (3 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.6.2.4 | ||
| 98 | SOLID FUEL FIREPLACE INSERTS | CO content (O2=13%) (0 - 4) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.6.2.6 | ||
| 99 | SOLID FUEL FIREPLACE INSERTS | TECHNICAL AND OPERATIONAL PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.6.2.6 | ||
| 100 | SOLID FUEL FIREPLACE INSERTS | temperature of the measuring corner and the floor (0 - 200) °C temperature of the fuel hopper (0 - 200)°C temperature of handles (0 - 200) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.4.7; A.4.8; A.4.9 | ||
| 101 | SOLID FUEL FIREPLACE INSERTS | tightness of the water space (0,1 - 0,6) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.4.9.5 | ||
| 102 | SOLID FUEL FIREPLACE INSERTS | thermal outlet safety device water temperature (0 - 120) °C water pressure (0,1 - 0,3) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.4.9.6 | ||
| 103 | SOLID FUEL COOKERS | FUEL PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 13229:2002 p. A.4.9.6 | ||
| 104 | SOLID FUEL COOKERS | moisture content in wood net calorific value (10 - 32) MJ/kg (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Procedura nr LGP/42/B wyd. 4 | ||
| 105 | SOLID FUEL COOKERS | fuel mass (0,1 - 300) kg Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.4.2 | ||
| 106 | SOLID FUEL COOKERS | FLUE GAS PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.4.2 | ||
| 107 | SOLID FUEL COOKERS | temperature (0 - 600) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.2.3.2; A.4.4.3 | ||
| 108 | SOLID FUEL COOKERS | pressure (-10 - 10) hPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.2.3.4. | ||
| 109 | SOLID FUEL COOKERS | Concentrations of carbon dioxide, carbon monoxide. CO2; (0,5 - 16) % CO; (0,0003 - 4,0) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 12815:2004 p. A.2.3; A.4.4.2 | |
| 110 | SOLID FUEL COOKERS | Concentrations of nitrogen monoxide, OGC. NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | |
| 111 | SOLID FUEL COOKERS | Dust concentration in flue gases Range (0,005 - 1) g/m3 Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Gravimetric method | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 | |
| 112 | SOLID FUEL COOKERS | AIR PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 | ||
| 113 | SOLID FUEL COOKERS | temperature (10 - 35) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.1.1; A.4.4.3 | ||
| 114 | SOLID FUEL COOKERS | WATER PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.1.1; A.4.4.3 | ||
| 115 | SOLID FUEL COOKERS | temperature (0 - 100) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.2.5; A.4.5 | ||
| 116 | SOLID FUEL COOKERS | volume flow rate (0 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.2.5; A.4.5 | ||
| 117 | SOLID FUEL COOKERS | HEAT BALANCE (calculated): Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.2.5; A.4.5 | ||
| 118 | SOLID FUEL COOKERS | heat input from fuel (3 - 60) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.4.5; A.4.9; A.4.12; A.6.2.2 | ||
| 119 | SOLID FUEL COOKERS | stack loss (5 - 40) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.4.4; A.6.2.1.1 | ||
| 120 | SOLID FUEL COOKERS | losses due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.4.4; A.6.2.1.2 | ||
| 121 | SOLID FUEL COOKERS | loss due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.4.6; A.6.2.1.3 | ||
| 122 | SOLID FUEL COOKERS | thermal efficiency (20 - 95) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.6.2.1 | ||
| 123 | SOLID FUEL COOKERS | total heat output (3 - 50)kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.6.2.2 | ||
| 124 | SOLID FUEL COOKERS | heat output of the water circuit (0 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.6.2.3 | ||
| 125 | SOLID FUEL COOKERS | heat output to the room (3 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.6.2.4 | ||
| 126 | SOLID FUEL COOKERS | CO content (O2=13%) (0 - 4) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.6.2.6 | ||
| 127 | SOLID FUEL COOKERS | TECHNICAL AND OPERATIONAL PARAMETERS Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.6.2.6 | ||
| 128 | SOLID FUEL COOKERS | temperature of the measuring corner and the floor (0 - 200) °C temperature of the fuel hopper (0 - 200)°C temperature of handles (0 - 200) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.4.7; A.4.10; A.4.12; A.4.16 | ||
| 129 | SOLID FUEL COOKERS | tightness of the water space (0,1 - 0,6) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.4.17 | ||
| 130 | SOLID FUEL COOKERS | thermal outlet safety device water temperature (0 - 120) °C water pressure (0,1 - 0,3) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.4.18 | ||
| 131 | SOLID FUEL COOKERS | boiling, water temperature (0 - 100) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.4.10 | ||
| 132 | SOLID FUEL COOKERS | baking, air temperature (0 - 300) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.4.11 | ||
| 133 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | FUEL PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12815:2004 p. A.4.11 | ||
| 134 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | moisture content in wood (10 - 50) % net calorific value (10 - 32) MJ/kg (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Procedura nr LGP/42/B wyd. 4 | ||
| 135 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | fuel mass (0,1 - 300) kg Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A3. | ||
| 136 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | FLUE GAS PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A3. | ||
| 137 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | temperature (0 - 600) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.2.3.2 | ||
| 138 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | pressure (-10 - 10) hPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.2.3.4; A4 | ||
| 139 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | Concentrations of carbon dioxide, carbon monoxide. CO2; (0,5 - 16) % CO; (0,0003 - 4,0) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 12809:2002 p. A.2.3.3 | |
| 140 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | Concentrations of nitrogen monoxide, OGC. NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | |
| 141 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | Dust concentration in flue gases Range (0,005 - 1) g/m3 Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Gravimetric method | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 | |
| 142 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | AIR PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 | ||
| 143 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | temperature (10 - 35) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.1.1. | ||
| 144 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | WATER PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.1.1. | ||
| 145 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | temperature (10 - 100)°C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.2.5 | ||
| 146 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | volume flow rate (0 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.2.5. | ||
| 147 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | HEAT BALANCE (calculated): Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.2.5. | ||
| 148 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | heat input from fuel (5 - 100) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.6.2.2 | ||
| 149 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | stack loss (5 - 40) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.6.2.1.1 | ||
| 150 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | losses due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.6.2.1.2 | ||
| 151 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | loss due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.6.2.1.3 | ||
| 152 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | thermal efficiency (20 - 95) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.6.2.1 | ||
| 153 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | total heat output (5 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.6.2.2 | ||
| 154 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | heat output of the water circuit (5 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.6.2.3. | ||
| 155 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | heat output to the room (5 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.6.2.4 | ||
| 156 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | CO content (O2=13%) (0 - 4) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.6.2.6 | ||
| 157 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | TECHNICAL AND OPERATIONAL PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.6.2.6 | ||
| 158 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | temperature of the measuring corner and the floor (0 - 200) °C temperature of the fuel hopper (0 - 200) °C temperature of handles (0 - 200) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.2; A.3 | ||
| 159 | HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW | tightness of the water space (0,1 - 0,6) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.4.10 | ||
| 160 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | FUEL PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 12809:2002 p. A.4.10 | ||
| 161 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | moisture content in wood ( 10 - 50) % net calorific value (10 - 32) MJ/kg (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Procedura nr LGP/42/B wyd. 4 | ||
| 162 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | fuel mass (0,1 - 300) kg Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 15250:2009 A3; A4.2 | ||
| 163 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | FLUE GAS PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 15250:2009 A3; A4.2 | ||
| 164 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | temperature (0 - 600) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 15250:2009 p. A2.3.2; A4.4.3 | ||
| 165 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | pressure (-10 - 10) hPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 15250:2009 p. A2.3.4; A4 | ||
| 166 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | Concentrations of carbon dioxide, carbon monoxide. CO2; (0,5 - 16) % CO; (0,0003 - 4,0) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 15250:2009 p. A2.3.3; A4.4.2 | |
| 167 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | Concentrations of nitrogen monoxide, OGC. NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | |
| 168 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | Dust concentration in flue gases Range (0,005 - 1) g/m3 Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Gravimetric method | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 | |
| 169 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | AIR PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 | ||
| 170 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | temperature (10 - 35) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 15250:2009 p. A1.1; A4.4.3 | ||
| 171 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | HEAT BALANCE (calculated): Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 15250:2009 p. A1.1; A4.4.3 | ||
| 172 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | heat energy supplied with the fuel (10 - 600) MJ Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 15250:2009 p. A6.2.2 | ||
| 173 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | stack loss (5 - 40) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 15250:2009 p. A6.2.1.2 | ||
| 174 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | losses due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 15250:2009 p. A6.2.1.3 | ||
| 175 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | loss due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 15250:2009 p. A6.2.1.4 | ||
| 176 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | thermal efficiency (20 - 95) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 15250:2009 p. A6.2.1.1 | ||
| 177 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | heat output (10 - 600) MJ Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 15250:2009 p. A6.2.2 | ||
| 178 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | flue gas mass flow (5 - 100) g/s Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 15250:2009 p. A6.2.3 | ||
| 179 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | CO content (O2=13%) (0-4)% Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 15250:2009 p. A6.2.4 | ||
| 180 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | mean temperature difference between the heater surface and the surroundings (0 - 200) K Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 15250:2009 p. A6.2.7 | ||
| 181 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | TECHNICAL AND OPERATIONAL PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 15250:2009 p. A6.2.7 | ||
| 182 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | surface temperature of the storage heater (0 - 200) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 15250:2009 p. A2.5; A4.6 | ||
| 183 | SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS | temperature of the measuring corner and the floor (0 - 200) °C temperature of the fuel hopper (0 - 200) °C temperature of handles (0 - 200) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 15250:2009 p. A2.2; A4.6; A4.7 | ||
| 184 | PELLET-FIRED LOCAL SPACE HEATERS | FUEL PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 15250:2009 p. A2.2; A4.6; A4.7 | ||
| 185 | PELLET-FIRED LOCAL SPACE HEATERS | moisture content in wood (0 - 50) % net calorific value (10 - 32) MJ/kg (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Procedura nr LGP/42/B wyd. 4 | ||
| 186 | PELLET-FIRED LOCAL SPACE HEATERS | fuel mass (0,1 - 300) kg Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A3; A 4.2 | ||
| 187 | PELLET-FIRED LOCAL SPACE HEATERS | -sampling and preparation of samples for analysis Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Procedura LGP/42/B | ||
| 188 | PELLET-FIRED LOCAL SPACE HEATERS | FLUE GAS PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Procedura LGP/42/B | ||
| 189 | PELLET-FIRED LOCAL SPACE HEATERS | temperature (0 - 600) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A2.3.2; A4.4.3 | ||
| 190 | PELLET-FIRED LOCAL SPACE HEATERS | pressure (-10 - 10) hPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A2.3.4; A4 | ||
| 191 | PELLET-FIRED LOCAL SPACE HEATERS | Concentrations of carbon dioxide, carbon monoxide. CO2; (0,5-16) % CO; (0,0003-4,0) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 14785:2009 p. A2.3.3; 4.4.2 | |
| 192 | PELLET-FIRED LOCAL SPACE HEATERS | Concentrations of nitrogen monoxide, OGC. NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | |
| 193 | PELLET-FIRED LOCAL SPACE HEATERS | Dust concentration in flue gases Range (0,002 - 1) g/m3 Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Gravimetric method | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 | |
| 194 | PELLET-FIRED LOCAL SPACE HEATERS | AIR PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8 | ||
| 195 | PELLET-FIRED LOCAL SPACE HEATERS | temperature (10 - 35) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A1.1; A4.4.3 | ||
| 196 | PELLET-FIRED LOCAL SPACE HEATERS | WATER PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A1.1; A4.4.3 | ||
| 197 | PELLET-FIRED LOCAL SPACE HEATERS | temperature (10 - 100) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A2.5; A4.5 | ||
| 198 | PELLET-FIRED LOCAL SPACE HEATERS | volume flow rate (0 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A2.5; A4.5 | ||
| 199 | PELLET-FIRED LOCAL SPACE HEATERS | HEAT BALANCE (calculated): Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A2.5; A4.5 | ||
| 200 | PELLET-FIRED LOCAL SPACE HEATERS | heat input from fuel (3 - 60) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A6.2.2 | ||
| 201 | PELLET-FIRED LOCAL SPACE HEATERS | stack loss (5 - 40) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A6.2.1.1 | ||
| 202 | PELLET-FIRED LOCAL SPACE HEATERS | losses due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A6.2.1.2 | ||
| 203 | PELLET-FIRED LOCAL SPACE HEATERS | loss due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A6.2.1.3 | ||
| 204 | PELLET-FIRED LOCAL SPACE HEATERS | thermal efficiency (20 - 95) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A6.2.1 | ||
| 205 | PELLET-FIRED LOCAL SPACE HEATERS | total heat output (3 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A6.2.2 | ||
| 206 | PELLET-FIRED LOCAL SPACE HEATERS | heat output of the water circuit (3 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A6.2.3 | ||
| 207 | PELLET-FIRED LOCAL SPACE HEATERS | heat output to the room (3 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A6.2.4 | ||
| 208 | PELLET-FIRED LOCAL SPACE HEATERS | flue gas mass flow (5 - 100) g/s Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A6.2.5 | ||
| 209 | PELLET-FIRED LOCAL SPACE HEATERS | CO content (O2=13%) (0 - 4)% Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A6.2.6 | ||
| 210 | PELLET-FIRED LOCAL SPACE HEATERS | TECHNICAL AND OPERATIONAL PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A6.2.6 | ||
| 211 | PELLET-FIRED LOCAL SPACE HEATERS | temperature of the measuring corner and the floor (0 - 200) °C temperature of the fuel hopper (0 - 200) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A2.2; A4.7; A4.8; A4.9 | ||
| 212 | PELLET-FIRED LOCAL SPACE HEATERS | temperature of handles (0 - 200) °C Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A2.2; A4.7; A4.8; A4.9 | ||
| 213 | PELLET-FIRED LOCAL SPACE HEATERS | tightness of the water space (0,1 - 0,6) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A4.9.2 | ||
| 214 | PELLET-FIRED LOCAL SPACE HEATERS | thermal outlet safety device water temperature (0 - 120) °C water pressure (0,1 - 0,3) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 14785:2009 p. A4.9.3 | ||
| 215 | HEATING BOILERS FOR SOLID FUELS | Measurement of electric energy consumption Range (2 - 4000) W Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Method: power transducers | PN-EN 303-5:2021-09 p. 5.7.7 | PN-EN 303-5+A1:2023-05 p. 5.7.7 | |
| 216 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | FUEL PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 303-5:2021-09 p. 5.7.7 | PN-EN 303-5+A1:2023-05 p. 5.7.7 | ||
| 217 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | moisture content in wood (10 - 50) % net calorific value (10 - 32) MJ/kg (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Procedura nr LGP/42/B wyd. 4 | ||
| 218 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | fuel mass (0,1 - 300) kg Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.4.2 | ||
| 219 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | FLUE GAS PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.4.2 | ||
| 220 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | temperature (15 - 1100) oC Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | ||
| 221 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | pressure (-10 - 10) hPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.2.3.4 | ||
| 222 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | Concentrations of carbon dioxide, carbon monoxide. CO2; (0,5 - 16) % CO; (0,0003 - 4,0) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | |
| 223 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | Concentrations of nitrogen monoxide, OGC. NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) | PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | |
| 224 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | Dust concentration in flue gases (0,002 - 1) g/m3 Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Gravimetric method | PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | |
| 225 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | AIR PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | ||
| 226 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | temperature (10 - 35) oC Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.4.4.3 | ||
| 227 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | WATER PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.4.4.3 | ||
| 228 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | temperature (10 - 100) oC Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 229 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | volume flow rate (0 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 230 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | HEAT BALANCE (calculated): Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 231 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | heat input from fuel (3 - 60) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.2 | ||
| 232 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | stack loss (5 - 40) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.2 | ||
| 233 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | losses due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.3 | ||
| 234 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | loss due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.4 | ||
| 235 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | thermal efficiency (20 - 95) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1 | ||
| 236 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | total heat output (2 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.2 | ||
| 237 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | heat output of the water circuit (1,5 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.3 | ||
| 238 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | heat output to the room (2 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.4 | ||
| 239 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | CO content (O2=13%) (0 - 4) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.6 | ||
| 240 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | flue gas mass flow (1-100) g/s (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 6.12 | ||
| 241 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | TECHNICAL AND OPERATIONAL PARAMETERS Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 6.12 | ||
| 242 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | temperature of the measuring corner and the floor (0 - 200) oC temperature of the fuel hopper (0 - 200) oC temperature of handles (0 - 200) oC Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6, | ||
| 243 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | tightness of the water space (0,1 - 0,6) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.10.6 | ||
| 244 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | thermal outlet safety device water temperature (0 - 120) oC Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.10.7 | ||
| 245 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | water pressure (0,1 - 0,3) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.10.7 | ||
| 246 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | tightness (5 - 75) Pa; (0,2 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5 | ||
| 247 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | tightness related to CO emission (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p 5.9.1 | ||
| 248 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | constant air loss (1)Pa; (0 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 Załącznik I | ||
| 249 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | measurement of electricity consumption (2 - 4000) W, method: power transducers Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p 6.11 | ||
| 250 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | temperature safety test Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.4 | ||
| 251 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | safety test under natural draught Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.5 | ||
| 252 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | operation of the safety temperature limiter (0 - 110) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-2-6:2023-06 p A.4.10.601.1 „N“ | PN-EN 16510-1:2023-06 p A.4.10.7 | ||
| 253 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | loss of electrical power supply (0 - 110) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-2-6:2023-06 p A.4.10.601.2 „N“ | PN-EN 16510-1:2023-06 p A.4.10.7 | ||
| 254 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | loss of heat removal (0 - 110) oC, (0 - 5) % CO Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.3 „N“ | ||
| 255 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES | efficiency (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6 | ||
| 256 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | FUEL PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6 | ||
| 257 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | moisture content in wood (10 - 50) % net calorific value (10 - 32) MJ/kg (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Procedura nr LGP/42/B wyd. 4 | ||
| 258 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | fuel mass (0,1 - 300) kg Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.4.2 | ||
| 259 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | FLUE GAS PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.4.2 | ||
| 260 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | temperature (15 - 1100) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-1:2023-06 p. 4.7.2,4.7.3, 4.7.8 „N“ | ||
| 261 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | pressure (-10 - 10) hPa Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-1:2023-06 p. 4.7.3, 4.7.4, 4.7.5 „N“ | ||
| 262 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | Concentrations of carbon dioxide, carbon monoxide. Range: CO2; (0,5 - 16) % CO; (0,0003 - 4,0) % Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-1:2023-06 p. 4.3 „N“ | |
| 263 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | Nitrogen monoxide, OGC concentrations NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated) Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) | PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“ | |
| 264 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | Dust concentration in flue gases (0,002 - 1) g/m3 Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Gravimetric method | PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N“ | |
| 265 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | AIR PARAMETERS: Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N“ | ||
| 266 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | temperature (10 - 35) oC Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.4.3 | ||
| 267 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | WATER PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.4.3 | ||
| 268 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | temperature (10 - 100) oC Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 269 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | volume flow rate (0 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 270 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | HEAT BALANCE (calculated): Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 271 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | heat input from fuel (3 - 60) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.2 | ||
| 272 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | stack loss (5 - 40) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.2 | ||
| 273 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | losses due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.3 | ||
| 274 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | loss due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.4 | ||
| 275 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | thermal efficiency (20 - 95) % Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-1:2023-06 p. 4.8.3, 4.8.6 „N“ | ||
| 276 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | total heat output (2 - 50) kW Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-1:2023-06 p. 4.8.1, 4.8.4 „N“ | ||
| 277 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | heat output of the water circuit (1,5 - 50) kW Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-1:2023-06 p. 4.8.2, 4.8.5 „N“ | ||
| 278 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | heat output to the room (2 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.4 | ||
| 279 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | CO content (O2=13%) (0 - 4)% Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.6 | ||
| 280 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | flue gas mass flow (1 - 100) g/s (calculated) Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“ | ||
| 281 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | TECHNICAL AND OPERATIONAL PARAMETERS: Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“ | ||
| 282 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | temperature of the measuring corner and the floor (0 - 200) oC temperature of the fuel hopper (0 - 200) oC temperature of handles (0 - 200) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 „ | PN-EN 16510-2-1:2023-06 p. 5.5, 5.6 „N“ | ||
| 283 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | tightness of the water space (0,1 - 0,6) MPa Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-1:2023-06 p. 5.3 „N“ | ||
| 284 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | thermal outlet safety device water temperature (0 - 120) oC water pressure (0,1 - 0,3) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.7 | ||
| 285 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | tightness (5 - 75)Pa; (0,2 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5 | ||
| 286 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | tightness related to CO emission (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p 5.9.1 | ||
| 287 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | constant air loss (1) Pa; (0 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 Załącznik I | ||
| 288 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | measurement of electrical energy consumption (2 - 4000) W power transducer method Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-1:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“ | ||
| 289 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | temperature safety test Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.4 | ||
| 290 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | safety test under natural draught Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.5 | ||
| 291 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | load-bearing capacity Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.2 | ||
| 292 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS | efficiency (calculated) seasonal space heating efficiency (calculated) energy efficiency index EEI (calculated) Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N“ | ||
| 293 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | FUEL PARAMETERS: Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N“ | ||
| 294 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | moisture content in wood (10 - 50) % net calorific value (10 - 32) MJ/kg (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Procedura nr LGP/42/B wyd. 4 | ||
| 295 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | fuel mass (0,1 - 300) kg Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.4.2 | ||
| 296 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | FLUE GAS PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.4.2 | ||
| 297 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | temperature (15 - 600) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-2:2023-06 p. 4.6.2,4.6.3 „N“ | ||
| 298 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | pressure (-10 - 10) hPa Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-2:2023-06 p. 4.6.4, 4.6.5„N“ | ||
| 299 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | Concentrations of carbon dioxide, carbon monoxide. CO2 (0,5 - 16) % CO (0,0003 - 4,0) % Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-2:2023-06 p. 4.2 „N“ | |
| 300 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | Concentrations of nitrogen monoxide, OGC. NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated) Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) | PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“ | |
| 301 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | Dust concentration in flue gases (0,002 - 1) g/m3 Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Gravimetric method | PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N“ | |
| 302 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | AIR PARAMETERS: Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N“ | ||
| 303 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | temperature (10 - 35) oC Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.4.3 | ||
| 304 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | WATER PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.4.3 | ||
| 305 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | temperature (10 -1 00) oC Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 306 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | volume flow rate (0 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 307 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | HEAT BALANCE (calculated): Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 308 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | heat input from fuel (3 - 60) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.2 | ||
| 309 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | stack loss (5 - 40) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.2 | ||
| 310 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | losses due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.3 | ||
| 311 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | loss due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.4 | ||
| 312 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | thermal efficiency (20 - 95) % Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-2:2023-06 p. 4.7.3, 4.7.6 „N“ | ||
| 313 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | total heat output (2 - 50) kW Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-2:2023-06 p. 4.7.1, 4.7.4 „N“ | ||
| 314 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | heat output of the water circuit (1,5 - 50) kW Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-2:2023-06 p. 4.7.2, 4.7.5 „N“ | ||
| 315 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | heat output to the room (2 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.4 | ||
| 316 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | CO content (O2=13%) (0 - 4)% Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.6 | ||
| 317 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | flue gas mass flow (1 - 100) g/s (calculated) Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N“ | ||
| 318 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | TECHNICAL AND OPERATIONAL PARAMETERS: Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N“ | ||
| 319 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | temperature of the measuring corner and the floor (0 - 200) oC temperature of the fuel hopper (0 - 200) oC temperature of handles (0 - 200) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-2:2023-06 p. 5.5, 5.6 „N“ | ||
| 320 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | tightness of the water space (0,1 - 0,6) MPa Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-2:2023-06 p. 5.3.3 „N“ | ||
| 321 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | thermal outlet safety device water temperature (0 - 120) oC water pressure (0,1 - 0,3) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.7 | ||
| 322 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | tightness (5 - 75) Pa; (0,2 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5 | ||
| 323 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | tightness related to CO emission (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p 5.9.1 | ||
| 324 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | constant air loss (1)Pa; (0 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 Załącznik I | ||
| 325 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | measurement of electrical energy consumption (2 - 4000) W Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Power transducer method | PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-2:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N“ | |
| 326 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | temperature safety test Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.4 | ||
| 327 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | safety test under natural draught Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.5 | ||
| 328 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES | efficiency (calculated) seasonal space heating efficiency (calculated) energy efficiency index EEI (calculated) Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N“ | ||
| 329 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | FUEL PARAMETERS: Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N“ | ||
| 330 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | moisture content in wood (10 - 50) % net calorific value (10 - 32) MJ/kg (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Procedura nr LGP/42/B wyd. 4 | ||
| 331 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | fuel mass (0,1 - 300) kg Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.4.2 | ||
| 332 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | FLUE GAS PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.4.2 | ||
| 333 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | temperature (15 - 600) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-6:2023-06 p. 4.7.2,4.7.3 „N“ | ||
| 334 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | pressure (-10 - 10) hPa Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-6:2023-06 p. 4.7.4, 4.7.5 „N“ | ||
| 335 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | Concentrations of carbon dioxide, carbon monoxide. Range: CO2; (0,5 - 16) % CO; (0,0003 - 4,0) % Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 16510-1:2023-06 p. A.4.4.2, A. | PN-EN 16510-2-6:2023-06 p. 4.3 „N“ | |
| 336 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | Concentrations of nitrogen monoxide, OGC. NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated) Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) | PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N“ | |
| 337 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | Dust concentration in flue gases (0,002 - 1) g/m3 Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Gravimetric method | PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N“ | |
| 338 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | AIR PARAMETERS: Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N“ | ||
| 339 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | temperature (10-35) oC Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.4.3 | ||
| 340 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | WATER PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.4.3 | ||
| 341 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | temperature (10 - 100) oC Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 342 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | volume flow rate (0 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 343 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | HEAT BALANCE (calculated): Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 344 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | heat input from fuel (3 - 60) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.2 | ||
| 345 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | stack loss (5 - 40) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.2 | ||
| 346 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | losses due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.3 | ||
| 347 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | loss due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.4 | ||
| 348 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | thermal efficiency (20 - 95) % Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-6:2023-06 p. 4.8.3, 4.8.6 „N“ | ||
| 349 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | total heat output (2 - 50) kW Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-6:2023-06 p. 4.8.1, 4.8.4 „N“ | ||
| 350 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | heat output of the water circuit (1,5 - 50) kW Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-6:2023-06 p. 4.8.2, 4.8.5 „N“ | ||
| 351 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | heat output to the room (2 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.4 | ||
| 352 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | CO content (O2=13%) (0 - 4)% Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.6 | ||
| 353 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | flue gas mass flow (1 - 100) g/s (calculated) Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N“ | ||
| 354 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | TECHNICAL AND OPERATIONAL PARAMETERS: Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N“ | ||
| 355 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | temperature of the measuring corner and the floor (0 - 200) oC temperature of the fuel hopper (0 - 200) oC temperature of handles (0 - 200) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-6:2023-06 p. 5.5.1, 5.5.2, 5.6 „N“ | ||
| 356 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | tightness of the water space (0,1 - 0,6) MPa Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-6:2023-06 p. 5.3.3 „N“ | ||
| 357 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | thermal outlet safety device water temperature (0 - 120) oC water pressure (0,1 - 0,3) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.7 | ||
| 358 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | tightness (5 - 75) Pa; (0,2 - 3) m3/h Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5 | PN-EN 16510-2-6:2023-06 p 5.1.2, 5.1.3 „N“ | ||
| 359 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | tightness related to CO emission (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p 5.9.1 | ||
| 360 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | constant air loss (1)Pa; (0 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 Załącznik I | ||
| 361 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | measurement of electrical energy consumption (2 - 4000) W Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Power transducer method | PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-6:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“ | |
| 362 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | temperature safety test Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.4 | ||
| 363 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | safety test under natural draught Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.5 | ||
| 364 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | operation of the safety temperature limiter (0 - 110) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.1„N“ | ||
| 365 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | loss of electrical power supply (0 - 110) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.2 „N“ | ||
| 366 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | loss of heat removal (0 - 110) oC, (0 - 5) % CO Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.3 „N“ | ||
| 367 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | load-bearing capacity Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.2 | ||
| 368 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING | efficiency (calculated), seasonal space heating efficiency (calculated) energy efficiency index EEI (calculated) Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N“ | ||
| 369 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | FUEL PARAMETERS: Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N“ | ||
| 370 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | moisture content in wood ( 10 - 50) % net calorific value (10 - 32) MJ/kg (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Procedura nr LGP/42/B wyd. 4 | ||
| 371 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | fuel mass (0,1 - 300) kg Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.4.2 | ||
| 372 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | FLUE GAS PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.4.2 | ||
| 373 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | temperature (15 - 600) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-3:2023-06 p. 4.6.2,4.6.3 „N” | ||
| 374 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | pressure (-10 - 10) hPa Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N” | ||
| 375 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | Concentrations of carbon dioxide, carbon monoxide. Range: CO2 (0,5 - 16) % CO (0,0003 - 4,0) % Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N” | |
| 376 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | Concentrations of nitrogen monoxide, OGC. NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated) Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) | PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-3:2023-06 p. 4.3, 4.4, „N” | |
| 377 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | Dust concentration in flue gases (0,002 - 1) g/m3 Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Gravimetric method | PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N” | |
| 378 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | AIR PARAMETERS: Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N” | ||
| 379 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | air temperature (10 - 35) oC Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.4.3 | ||
| 380 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | WATER PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.4.3 | ||
| 381 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | water temperature (10 - 100) oC Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 382 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | water volume flow rate (0 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 383 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | HEAT BALANCE: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 384 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | heat input from fuel (3 - 60) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.2 | ||
| 385 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | stack loss (5 - 40) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1. | ||
| 386 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | losses due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.3 | ||
| 387 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | loss due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.4 | ||
| 388 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | thermal efficiency (20 - 95) % Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-3:2023-06 p. 4.7.3, 4.7.6 „N” | ||
| 389 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | total heat output (2 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.2 | ||
| 390 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | heat output of the water circuit (1,5 - 50) kW Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-3:2023-06 p. 4.7.2, 4.7.5 „N” | ||
| 391 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | heat output to the room (2 - 50) kW Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.6.2.4 | PN-EN 16510-2-3:2023-06 p. 4.7.1, 4.7.4 „N” | ||
| 392 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | flue gas mass flow (1 - 100) g/s (calculated) Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N” | ||
| 393 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | TECHNICAL AND OPERATIONAL PARAMETERS: Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N” | ||
| 394 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | temperature of the measuring corner and the floor (0 - 200) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.6 | PN-EN 16510-2-3:2023-06 p.4.1 „N” | ||
| 395 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | temperature of the fuel hopper (0 - 200) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4 | PN-EN 16510-2-3:2023-06 p. 5.5 „N” | ||
| 396 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | TECHNICAL AND OPERATIONAL PARAMETERS: Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4 | PN-EN 16510-2-3:2023-06 p. 5.5 „N” | ||
| 397 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | temperature of handles (0 - 200) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.5 | PN-EN 16510-2-3:2023-06 p.5.6 „N” | ||
| 398 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | tightness of the water space (0,1 - 0,6) MPa Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-3:2023-06 p. 5.9 „N” | ||
| 399 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | thermal outlet safety device water temperature (0 - 120) oC water pressure (0,1 - 0,3) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.7 | ||
| 400 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | tightness (5 - 75) Pa; (0,2 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5 | ||
| 401 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | tightness related to CO emission (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p 5.9.1 | ||
| 402 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | constant air loss (1) Pa; (0 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 Załącznik I | ||
| 403 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | measurement of electrical energy consumption (2 - 4000) W Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Power transducer method | PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-3:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N” | |
| 404 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | temperature safety test Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.4 | ||
| 405 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | safety test under natural draught Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.5 | ||
| 406 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | efficiency (calculated), seasonal space heating efficiency (calculated), EEI (calculated) Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-3:2023-06 p. 4.7.7, 4.7.8 „N” | ||
| 407 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | measurement of oven temperature, air temperature (0 - 300) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-2-3:2023-06 A.4.301.1 „N” | ||
| 408 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | boiling test on a hotplate, water temperature (0 - 100) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-2-3:2023-06 A.4.301.2 „N” | ||
| 409 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS | baking, air temperature (0 - 300) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-2-3:2023-06 A.4.301.3 „N” | ||
| 410 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | FUEL PARAMETERS: Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-2-3:2023-06 A.4.301.3 „N” | ||
| 411 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | moisture content in wood (10 - 50) % net calorific value (10 - 32) MJ/kg (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Procedura nr LGP/42/B wyd. 4 | ||
| 412 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | fuel mass (0,1 - 300) kg Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.4.2 | ||
| 413 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | FLUE GAS PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.4.2 | ||
| 414 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | temperature (15 - 1100) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 A.4.4.3, A.6.2, 6.2.1 | PN-EN 16510-2-5:2025-10 p. 4.7.2,4.7.5 „N“ | ||
| 415 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | pressure (-10 - 10) hPa Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p. A.2.3.4, 6.5 | PN-EN 16510-2-5:2025-10 p. 4.7.3, 4.7.4, 4.7.5 „N“ | ||
| 416 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | Concentrations of carbon dioxide, carbon monoxide. CO2; (0,5 - 16) % CO; (0,0003 - 4,0) % Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-5:2025-10 p. 4.3 „N“ | |
| 417 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | Concentrations of nitrogen monoxide, OGC. NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated) Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) | PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-5:2025-10 p. 4.4, 4.5 „N“ | |
| 418 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | Dust concentration in flue gases (0,002 - 1) g/m3 Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Gravimetric method | PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-5:2025-10 p. 4.6 „N“ | |
| 419 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | AIR PARAMETERS: Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-5:2025-10 p. 4.6 „N“ | ||
| 420 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | temperature (10 - 35) oC Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.4.3 | ||
| 421 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | WATER PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.4.3 | ||
| 422 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | temperature (10 - 100) oC Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 423 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | volume flow rate (0 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 424 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | HEAT BALANCE (calculated): Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 425 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | heat input from fuel (3 - 60) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.2 | ||
| 426 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | -thermal energy supplied with the fuel (10-600) MJ Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-2-5:2025-10 p. A.6.2.501 „N“ | ||
| 427 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | stack loss (5 - 40) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.2 | ||
| 428 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | losses due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.3 | ||
| 429 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | loss due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.4 | ||
| 430 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | thermal efficiency (20 - 95) % Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-5:2025-10 p. 4.8.3 „N“ | ||
| 431 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | total heat output (2 - 50) kW Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2 „N“ | ||
| 432 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | heat output of the water circuit (1,5 - 50) kW Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-5:2025-10 p. 4.8.2, 4.8.4, A.6.2.3„N“ | ||
| 433 | - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | heat output to the room (2 - 50) kW Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.6.2.4 | PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2, A.6.2.4, A.6.2.501 „N“ | ||
| 434 | - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | CO content (O2=13%) (0 - 4)% Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.6 | ||
| 435 | - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | flue gas mass flow (1 - 100) g/s (calculated) Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-5:2025-10 p. 4.7.4 „N“ | ||
| 436 | - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | -mean temperature difference between the appliance surface and the surroundings (0 - 200) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-2-5:2025-10 p. 4.8.502, A.2.501, A.6.2.502 „N“ | ||
| 437 | - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | TECHNICAL AND OPERATIONAL PARAMETERS: Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-2-5:2025-10 p. 4.8.502, A.2.501, A.6.2.502 „N“ | ||
| 438 | - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | temperature of the measuring corner and the floor (0 - 200) oC temperature of the fuel hopper (0 - 200) oC temperature of handles (0 - 200) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-5:2025-10 p. 4.7.5, 5.5, A.4.10 „N“ | ||
| 439 | - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | tightness of the water space (0,1 - 0,6) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.10.6 | ||
| 440 | - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | thermal outlet safety device water temperature (0 - 120) oC water pressure (0,1 - 0,3) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.7 | ||
| 441 | - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | tightness (5 - 75) Pa; (0,2 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5 | ||
| 442 | - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | tightness related to CO emission (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p 5.9.1 | ||
| 443 | - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | constant air loss (1) Pa; (0 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 Załącznik I | ||
| 444 | - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | measurement of electricity consumption (2 - 4000) W power transducer method Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-5:2025-10 p. 4.8.6, 4.8.7 „N“ | ||
| 445 | - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | temperature safety test Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.4.10.4 | PN-EN 16510-2-5:2025-10 p.A.4.10.2 „N“ | ||
| 446 | - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | -test of the operation of the heat discharge control system and of the safety heat exchanger Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-5:2025-10 p.A.4.10.7 „N“ | ||
| 447 | - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | load-bearing capacity Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.2 | ||
| 448 | - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES | efficiency (calculated) seasonal space heating efficiency (calculated) energy efficiency index EEI (calculated) Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-5:2025-10 p. 4.8.4, 4.8.5 „N“ | ||
| 449 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | FUEL PARAMETERS: Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-5:2025-10 p. 4.8.4, 4.8.5 „N“ | ||
| 450 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | moisture content in wood (10 - 50) % net calorific value (10 - 32) MJ/kg (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
Procedura nr LGP/42/B wyd. 4 | ||
| 451 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | fuel mass (0,1 - 300) kg Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.4.2 | ||
| 452 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | FLUE GAS PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.4.2 | ||
| 453 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | temperature (15 - 600) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-7:2025-10 p. 4.7.2, 4.7.3 „N“ | ||
| 454 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | pressure (-10 - 10) hPa Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-7:2025-10 p. 4.7.4, 4.7.5„N“ | ||
| 455 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | Concentrations of carbon dioxide, carbon monoxide. CO2 (0,5 - 16) % CO (0,0003 - 4,0) % Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Non-dispersive infrared spectrometry (NDIR) | PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-7:2025-10 p. 4.3 „N“ | |
| 456 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | Concentrations of nitrogen monoxide, OGC. NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated) Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) | PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-7:2025-10 p. 4.4, 4.5 „N“ | |
| 457 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | Dust concentration in flue gases (0,002 - 1) g/m3 Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Gravimetric method | PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-7:2025-10 p. 4.6 „N“ | |
| 458 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | AIR PARAMETERS: Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-7:2025-10 p. 4.6 „N“ | ||
| 459 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | temperature (10 - 35) oC Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.4.3 | ||
| 460 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | WATER PARAMETERS: Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.4.3 | ||
| 461 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | temperature (10 -1 00) oC Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 462 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | volume flow rate (0 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 463 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | HEAT BALANCE (calculated): Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p. A.4.5.2 | ||
| 464 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | heat input from fuel (3 - 60) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.2 | ||
| 465 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | stack loss (5 - 40) % Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.2 | ||
| 466 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | losses due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.3 | ||
| 467 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | loss due to incomplete combustion Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.1.4 | ||
| 468 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | thermal efficiency (20 - 95) % Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-7:2025-10 p. 4.8.4, 4.8.7 „N“ | ||
| 469 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | total heat output (2 - 50) kW Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-7:2025-10 p. 4.8.2, 4.8.5 „N“ | ||
| 470 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | heat output of the water circuit (1,5 - 50) kW Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-7:2025-10 p. 4.8.3, 4.8.6 „N“ | ||
| 471 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | heat output to the room (2 - 50) kW Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.4 | ||
| 472 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | CO content (O2=13%) (0 - 4)% Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p.A.6.2.6 | ||
| 473 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | flue gas mass flow (1 - 100) g/s (calculated) Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-7:2025-10 p. 4.7.6, 4.7.7 „N“ | ||
| 474 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | TECHNICAL AND OPERATIONAL PARAMETERS: Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-7:2025-10 p. 4.7.6, 4.7.7 „N“ | ||
| 475 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | temperature of the measuring corner and the floor (0 - 200) oC temperature of the fuel hopper (0 - 200) oC temperature of handles (0 - 200) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10.4, 5.4, 5.5, 5.6 | PN-EN 16510-2-7:2025-10 p. 5.5.1, 5.5.3, 5.6 „N“ | ||
| 476 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | tightness of the water space (0,1 - 0,6) MPa Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-7:2025-10 p. A.4.10.6 „N“ | ||
| 477 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | thermal outlet safety device water temperature (0 - 120) oC water pressure (0,1 - 0,3) MPa Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.7 | ||
| 478 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | tightness (5 - 75) Pa; (0,2 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5 | ||
| 479 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | tightness related to CO emission (calculated) Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p 5.9.1 | ||
| 480 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | constant air loss (1)Pa; (0 - 3) m3/h Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 Załącznik I | ||
| 481 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | measurement of electrical energy consumption (2 - 4000) W Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
Power transducer method | PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-7:2025-10 p. 4.8.10, 4.8.11, 4.8.12 „N“ | |
| 482 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | temperature safety test Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.4.10.4 | PN-EN 16510-2-7:2025-10 p. 4.7.8, A.4.10.4.2. „N“ | ||
| 483 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | operation of the temperature limiter Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.702, A.4.10.7.703 „N“ | ||
| 484 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | loss of electrical power supply (0 - 110) oC Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.2 „N“ | ||
| 485 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | loss of heat removal (0 - 110) oC, (0 - 5) % CO Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.1, A.4.10.7.703.1.3 „N“ | ||
| 486 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | load-bearing capacity Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC |
PN-EN 16510-1:2023-06 p A.4.10.2 | ||
| 487 | RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS | efficiency (calculated) seasonal space heating efficiency (calculated) energy efficiency index EEI (calculated) Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011. |
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-7:2025-10 p. 4.8.8, 4.8.9 „N“ | ||
| 488 | Type of activity: | efficiency (calculated) seasonal space heating efficiency (calculated) energy efficiency index EEI (calculated) Regulated area: The laboratory meets the requirements set out in Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, subpoint 3 of Regulation No 305/2011) in the above scope. |
Dokument odniesienia: | ||
| 489 | ASSESSMENT OF PERFORMANCE, ON THE BASIS OF TESTING, CALCULATION, TABULATED VALUES OR DESCRIPTIVE DOCUMENTATION OF THE CONSTRUCTION PRODUCT (System 3) | Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC Regulated area: The laboratory meets the requirements set out in Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, subpoint 3 of Regulation No 305/2011) in the above scope. |
Dokument odniesienia: | ||
| 490 | Commission decision number | Product(s) Regulated area: The laboratory meets the requirements set out in Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, subpoint 3 of Regulation No 305/2011) in the above scope. |
Zharmonizowane specyfikacje techniczne | ||
| 491 | 99/471/WE | Space heaters fired with solid and liquid fuels Regulated area: The laboratory meets the requirements set out in Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, subpoint 3 of Regulation No 305/2011) in the above scope. |
EN 16510-2-1:2022 | EN 16510-2-2:2022 | EN 16510-2-3:2022 | EN 16510-2-6:2022 | EN 16510-2-5:2025 | EN 16510-2-7:2025 | ||
Reference standards (330)
Dokument odniesienia:
EN 16510-2-1:2022
EN 16510-2-2:2022
EN 16510-2-3:2022
EN 16510-2-5:2025
EN 16510-2-6:2022
EN 16510-2-7:2025
PN-EN 12809:2002 p. A.1.1.
PN-EN 12809:2002 p. A.2.3.2
PN-EN 12809:2002 p. A.2.3.3
PN-EN 12809:2002 p. A.2.3.4; A4
PN-EN 12809:2002 p. A.2.5
PN-EN 12809:2002 p. A.2.5.
PN-EN 12809:2002 p. A.2; A.3
PN-EN 12809:2002 p. A.4.10
PN-EN 12809:2002 p. A.6.2.1
PN-EN 12809:2002 p. A.6.2.1.1
PN-EN 12809:2002 p. A.6.2.1.2
PN-EN 12809:2002 p. A.6.2.1.3
PN-EN 12809:2002 p. A.6.2.2
PN-EN 12809:2002 p. A.6.2.3.
PN-EN 12809:2002 p. A.6.2.4
PN-EN 12809:2002 p. A.6.2.6
PN-EN 12809:2002 p. A3.
PN-EN 12815:2004 p. A.1.1; A.4.4.3
PN-EN 12815:2004 p. A.2.3.2; A.4.4.3
PN-EN 12815:2004 p. A.2.3.4.
PN-EN 12815:2004 p. A.2.3; A.4.4.2
PN-EN 12815:2004 p. A.2.5; A.4.5
PN-EN 12815:2004 p. A.4.10
PN-EN 12815:2004 p. A.4.11
PN-EN 12815:2004 p. A.4.17
PN-EN 12815:2004 p. A.4.18
PN-EN 12815:2004 p. A.4.2
PN-EN 12815:2004 p. A.4.4; A.6.2.1.1
PN-EN 12815:2004 p. A.4.4; A.6.2.1.2
PN-EN 12815:2004 p. A.4.5; A.4.9; A.4.12; A.6.2.2
PN-EN 12815:2004 p. A.4.6; A.6.2.1.3
PN-EN 12815:2004 p. A.4.7; A.4.10; A.4.12; A.4.16
PN-EN 12815:2004 p. A.6.2.1
PN-EN 12815:2004 p. A.6.2.2
PN-EN 12815:2004 p. A.6.2.3
PN-EN 12815:2004 p. A.6.2.4
PN-EN 12815:2004 p. A.6.2.6
PN-EN 13229:2002 p. A.4.2
PN-EN 13229:2002 p. A.4.4.2
PN-EN 13229:2002 p. A.4.4.3
PN-EN 13229:2002 p. A.4.5.2
PN-EN 13229:2002 p. A.4.7; A.4.8; A.4.9
PN-EN 13229:2002 p. A.4.9.5
PN-EN 13229:2002 p. A.4.9.6
PN-EN 13229:2002 p. A.6.2.1
PN-EN 13229:2002 p. A.6.2.1.1
PN-EN 13229:2002 p. A.6.2.1.2
PN-EN 13229:2002 p. A.6.2.1.3
PN-EN 13229:2002 p. A.6.2.2
PN-EN 13229:2002 p. A.6.2.3
PN-EN 13229:2002 p. A.6.2.4
PN-EN 13229:2002 p. A.6.2.6
PN-EN 13229:2002 p. A2.3.4;A.4
PN-EN 13240:2008 p. A.4.2
PN-EN 13240:2008 p. A.4.4.2
PN-EN 13240:2008 p. A.4.4.3
PN-EN 13240:2008 p. A.4.5.2
PN-EN 13240:2008 p. A.4.7; A.4.8; A.4.9
PN-EN 13240:2008 p. A.4.9.4
PN-EN 13240:2008 p. A.4.9.5
PN-EN 13240:2008 p. A.6.2.1
PN-EN 13240:2008 p. A.6.2.1.1
PN-EN 13240:2008 p. A.6.2.1.2
PN-EN 13240:2008 p. A.6.2.1.3
PN-EN 13240:2008 p. A.6.2.2
PN-EN 13240:2008 p. A.6.2.3
PN-EN 13240:2008 p. A.6.2.4
PN-EN 13240:2008 p. A.6.2.6
PN-EN 13240:2008 p. A2.3.4; A.4
PN-EN 14785:2009 p. A1.1; A4.4.3
PN-EN 14785:2009 p. A2.2; A4.7; A4.8; A4.9
PN-EN 14785:2009 p. A2.3.2; A4.4.3
PN-EN 14785:2009 p. A2.3.3; 4.4.2
PN-EN 14785:2009 p. A2.3.4; A4
PN-EN 14785:2009 p. A2.5; A4.5
PN-EN 14785:2009 p. A3; A 4.2
PN-EN 14785:2009 p. A4.9.2
PN-EN 14785:2009 p. A4.9.3
PN-EN 14785:2009 p. A6.2.1
PN-EN 14785:2009 p. A6.2.1.1
PN-EN 14785:2009 p. A6.2.1.2
PN-EN 14785:2009 p. A6.2.1.3
PN-EN 14785:2009 p. A6.2.2
PN-EN 14785:2009 p. A6.2.3
PN-EN 14785:2009 p. A6.2.4
PN-EN 14785:2009 p. A6.2.5
PN-EN 14785:2009 p. A6.2.6
PN-EN 15250:2009 A3; A4.2
PN-EN 15250:2009 p. A1.1; A4.4.3
PN-EN 15250:2009 p. A2.2; A4.6; A4.7
PN-EN 15250:2009 p. A2.3.2; A4.4.3
PN-EN 15250:2009 p. A2.3.3; A4.4.2
PN-EN 15250:2009 p. A2.3.4; A4
PN-EN 15250:2009 p. A2.5; A4.6
PN-EN 15250:2009 p. A6.2.1.1
PN-EN 15250:2009 p. A6.2.1.2
PN-EN 15250:2009 p. A6.2.1.3
PN-EN 15250:2009 p. A6.2.1.4
PN-EN 15250:2009 p. A6.2.2
PN-EN 15250:2009 p. A6.2.3
PN-EN 15250:2009 p. A6.2.4
PN-EN 15250:2009 p. A6.2.7
PN-EN 16510-1:2023-06 6.12
PN-EN 16510-1:2023-06 A.4.4.3, A.6.2
PN-EN 16510-1:2023-06 A.4.4.3, A.6.2, 6.2.1
PN-EN 16510-1:2023-06 Załącznik I
PN-EN 16510-1:2023-06 p 5.9.1
PN-EN 16510-1:2023-06 p 6.11
PN-EN 16510-1:2023-06 p A.4.10.2
PN-EN 16510-1:2023-06 p A.4.10.4
PN-EN 16510-1:2023-06 p A.4.10.5
PN-EN 16510-1:2023-06 p A.4.10.7
PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6,
PN-EN 16510-1:2023-06 p. A.2.3.4
PN-EN 16510-1:2023-06 p. A.2.3.4, 6.5
PN-EN 16510-1:2023-06 p. A.4.10.6
PN-EN 16510-1:2023-06 p. A.4.10.7
PN-EN 16510-1:2023-06 p. A.4.4.2, A.
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F
PN-EN 16510-1:2023-06 p. A.4.4.3
PN-EN 16510-1:2023-06 p. A.4.5.2
PN-EN 16510-1:2023-06 p.A.4.2
PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E
PN-EN 16510-1:2023-06 p.A.4.4.3
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 „
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6,
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.5
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.6
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10.4, 5.4, 5.5, 5.6
PN-EN 16510-1:2023-06 p.A.6.2.1
PN-EN 16510-1:2023-06 p.A.6.2.1.
PN-EN 16510-1:2023-06 p.A.6.2.1.2
PN-EN 16510-1:2023-06 p.A.6.2.1.3
PN-EN 16510-1:2023-06 p.A.6.2.1.4
PN-EN 16510-1:2023-06 p.A.6.2.2
PN-EN 16510-1:2023-06 p.A.6.2.3
PN-EN 16510-1:2023-06 p.A.6.2.4
PN-EN 16510-1:2023-06 p.A.6.2.6
PN-EN 16510-2-1:2023-06 p. 4.3 „N“
PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“
PN-EN 16510-2-1:2023-06 p. 4.6 „N“
PN-EN 16510-2-1:2023-06 p. 4.7.2,4.7.3, 4.7.8 „N“
PN-EN 16510-2-1:2023-06 p. 4.7.3, 4.7.4, 4.7.5 „N“
PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“
PN-EN 16510-2-1:2023-06 p. 4.8.1, 4.8.4 „N“
PN-EN 16510-2-1:2023-06 p. 4.8.2, 4.8.5 „N“
PN-EN 16510-2-1:2023-06 p. 4.8.3, 4.8.6 „N“
PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N“
PN-EN 16510-2-1:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“
PN-EN 16510-2-1:2023-06 p. 5.3 „N“
PN-EN 16510-2-1:2023-06 p. 5.5, 5.6 „N“
PN-EN 16510-2-2:2023-06 p. 4.2 „N“
PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“
PN-EN 16510-2-2:2023-06 p. 4.5 „N“
PN-EN 16510-2-2:2023-06 p. 4.6.2,4.6.3 „N“
PN-EN 16510-2-2:2023-06 p. 4.6.4, 4.6.5„N“
PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N“
PN-EN 16510-2-2:2023-06 p. 4.7.1, 4.7.4 „N“
PN-EN 16510-2-2:2023-06 p. 4.7.2, 4.7.5 „N“
PN-EN 16510-2-2:2023-06 p. 4.7.3, 4.7.6 „N“
PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N“
PN-EN 16510-2-2:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N“
PN-EN 16510-2-2:2023-06 p. 5.3.3 „N“
PN-EN 16510-2-2:2023-06 p. 5.5, 5.6 „N“
PN-EN 16510-2-3:2023-06 A.4.301.1 „N”
PN-EN 16510-2-3:2023-06 A.4.301.2 „N”
PN-EN 16510-2-3:2023-06 A.4.301.3 „N”
PN-EN 16510-2-3:2023-06 p. 4.3, 4.4, „N”
PN-EN 16510-2-3:2023-06 p. 4.5 „N”
PN-EN 16510-2-3:2023-06 p. 4.6.2,4.6.3 „N”
PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”
PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”
PN-EN 16510-2-3:2023-06 p. 4.7.1, 4.7.4 „N”
PN-EN 16510-2-3:2023-06 p. 4.7.2, 4.7.5 „N”
PN-EN 16510-2-3:2023-06 p. 4.7.3, 4.7.6 „N”
PN-EN 16510-2-3:2023-06 p. 4.7.7, 4.7.8 „N”
PN-EN 16510-2-3:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”
PN-EN 16510-2-3:2023-06 p. 5.5 „N”
PN-EN 16510-2-3:2023-06 p. 5.9 „N”
PN-EN 16510-2-3:2023-06 p.4.1 „N”
PN-EN 16510-2-3:2023-06 p.5.6 „N”
PN-EN 16510-2-5:2025-10 p. 4.3 „N“
PN-EN 16510-2-5:2025-10 p. 4.4, 4.5 „N“
PN-EN 16510-2-5:2025-10 p. 4.6 „N“
PN-EN 16510-2-5:2025-10 p. 4.7.2,4.7.5 „N“
PN-EN 16510-2-5:2025-10 p. 4.7.3, 4.7.4, 4.7.5 „N“
PN-EN 16510-2-5:2025-10 p. 4.7.4 „N“
PN-EN 16510-2-5:2025-10 p. 4.7.5, 5.5, A.4.10 „N“
PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2 „N“
PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2, A.6.2.4, A.6.2.501 „N“
PN-EN 16510-2-5:2025-10 p. 4.8.2, 4.8.4, A.6.2.3„N“
PN-EN 16510-2-5:2025-10 p. 4.8.3 „N“
PN-EN 16510-2-5:2025-10 p. 4.8.4, 4.8.5 „N“
PN-EN 16510-2-5:2025-10 p. 4.8.502, A.2.501, A.6.2.502 „N“
PN-EN 16510-2-5:2025-10 p. 4.8.6, 4.8.7 „N“
PN-EN 16510-2-5:2025-10 p. A.6.2.501 „N“
PN-EN 16510-2-5:2025-10 p.A.4.10.2 „N“
PN-EN 16510-2-5:2025-10 p.A.4.10.7 „N“
PN-EN 16510-2-6:2023-06 p 5.1.2, 5.1.3 „N“
PN-EN 16510-2-6:2023-06 p A.4.10.601.1 „N“
PN-EN 16510-2-6:2023-06 p A.4.10.601.1„N“
PN-EN 16510-2-6:2023-06 p A.4.10.601.2 „N“
PN-EN 16510-2-6:2023-06 p A.4.10.601.3 „N“
PN-EN 16510-2-6:2023-06 p. 4.3 „N“
PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N“
PN-EN 16510-2-6:2023-06 p. 4.6 „N“
PN-EN 16510-2-6:2023-06 p. 4.7.2,4.7.3 „N“
PN-EN 16510-2-6:2023-06 p. 4.7.4, 4.7.5 „N“
PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N“
PN-EN 16510-2-6:2023-06 p. 4.8.1, 4.8.4 „N“
PN-EN 16510-2-6:2023-06 p. 4.8.2, 4.8.5 „N“
PN-EN 16510-2-6:2023-06 p. 4.8.3, 4.8.6 „N“
PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N“
PN-EN 16510-2-6:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“
PN-EN 16510-2-6:2023-06 p. 5.3.3 „N“
PN-EN 16510-2-6:2023-06 p. 5.5.1, 5.5.2, 5.6 „N“
PN-EN 16510-2-7:2025-10 p A.4.10.7.702, A.4.10.7.703 „N“
PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.1, A.4.10.7.703.1.3 „N“
PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.2 „N“
PN-EN 16510-2-7:2025-10 p. 4.3 „N“
PN-EN 16510-2-7:2025-10 p. 4.4, 4.5 „N“
PN-EN 16510-2-7:2025-10 p. 4.6 „N“
PN-EN 16510-2-7:2025-10 p. 4.7.2, 4.7.3 „N“
PN-EN 16510-2-7:2025-10 p. 4.7.4, 4.7.5„N“
PN-EN 16510-2-7:2025-10 p. 4.7.6, 4.7.7 „N“
PN-EN 16510-2-7:2025-10 p. 4.7.8, A.4.10.4.2. „N“
PN-EN 16510-2-7:2025-10 p. 4.8.10, 4.8.11, 4.8.12 „N“
PN-EN 16510-2-7:2025-10 p. 4.8.2, 4.8.5 „N“
PN-EN 16510-2-7:2025-10 p. 4.8.3, 4.8.6 „N“
PN-EN 16510-2-7:2025-10 p. 4.8.4, 4.8.7 „N“
PN-EN 16510-2-7:2025-10 p. 4.8.8, 4.8.9 „N“
PN-EN 16510-2-7:2025-10 p. 5.5.1, 5.5.3, 5.6 „N“
PN-EN 16510-2-7:2025-10 p. A.4.10.6 „N“
PN-EN 297:2002 p. 4.1.6.7
PN-EN 303-5 +A1:2023-05 p. 5.12
PN-EN 303-5 +A1:2023-05 p. 5.14
PN-EN 303-5 +A1:2023-05 p. 5.16.2
PN-EN 303-5 +A1:2023-05 p. 5.16.3
PN-EN 303-5 +A1:2023-05 p. 5.16.4
PN-EN 303-5 +A1:2023-05 p. 5.16.6, 5.18.1
PN-EN 303-5 +A1:2023-05 p. 5.17
PN-EN 303-5 +A1:2023-05 p. 5.7.4
PN-EN 303-5 +A1:2023-05 p. 5.7.5
PN-EN 303-5+A1:2023-05 p. 5.10
PN-EN 303-5+A1:2023-05 p. 5.11
PN-EN 303-5+A1:2023-05 p. 5.12
PN-EN 303-5+A1:2023-05 p. 5.13
PN-EN 303-5+A1:2023-05 p. 5.15
PN-EN 303-5+A1:2023-05 p. 5.2
PN-EN 303-5+A1:2023-05 p. 5.2, 5.6.2, 5.6.3, 5.7.2, 5,7,3
PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8
PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8
PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.3; 5.6.4
PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.3
PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.7.1.1, 5.7.1.2, 5.7.2, 5.7.3, 5.9.1
PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.9.2
PN-EN 303-5+A1:2023-05 p. 5.6.3
PN-EN 303-5+A1:2023-05 p. 5.7.7
PN-EN 303-5+A1:2023-05 p. 5.9.3
PN-EN 303-5:2012 p. 5.10.3.2
PN-EN 303-5:2012 p. 5.12
PN-EN 303-5:2012 p. 5.13
PN-EN 303-5:2012 p. 5.14
PN-EN 303-5:2012 p. 5.15
PN-EN 303-5:2012 p. 5.2
PN-EN 303-5:2012 p. 5.2, 5.7.3, 5.7.4
PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9
PN-EN 303-5:2012 p. 5.6
PN-EN 303-5:2012 p. 5.7.1; 5.7.3
PN-EN 303-5:2012 p. 5.7.3
PN-EN 303-5:2012 p.5.10.3
PN-EN 303-5:2012 p.5.11
PN-EN 303-5:2012 p.5.2; 5.7.2; 5.7.3; 5.8.2
PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.10.2
PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.8.1.1; 5.8.1.2; 5.8.2; 5.8.3; 5.10.1
PN-EN 303-5:2021-09 p. 5.15
PN-EN 303-5:2021-09 p. 5.16.2
PN-EN 303-5:2021-09 p. 5.16.3
PN-EN 303-5:2021-09 p. 5.16.4
PN-EN 303-5:2021-09 p. 5.16.6, 5.18.1
PN-EN 303-5:2021-09 p. 5.2
PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8
PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8
PN-EN 303-5:2021-09 p. 5.2; 5.6.3; 5.6.4
PN-EN 303-5:2021-09 p. 5.6.1; 5.6.3
PN-EN 303-5:2021-09 p. 5.6.3
PN-EN 303-5:2021-09 p. 5.7.7
PN-EN 303-5:2021-09 p. 5.9.3
PN-EN 303-5:2021-09 p.5.10
PN-EN 303-5:2021-09 p.5.11
PN-EN 303-5:2021-09 p.5.12
PN-EN 303-5:2021-09 p.5.13
PN-EN 303-5:2021-09 p.5.2; 5.6.2; 5.6.3; 5.7.2; 5.7.3
PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.7.1.1; 5.7.1.2; 5.7.2; 5.7.3; 5.9.1
PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.9.2
PN-EN 303-5:2021-09 p.5.9.3
PN-EN 304:2017-11 p. 6.15
PN-EN 304:2017-11 p. 6.6
PN-EN 304:2017-11 p. A.8.3
PN-EN 304:2017-11 rys.4,5,6
PN-M-34452:1999 p. 4.3.2
PN-M-34452:1999 p. 4.3.3
PN-M-34452:1999 p. 4.3.6
PN-M-34452:1999 p. 4.3.6.3
PN-M-34452:1999 p. 5.3.7
PN-M-34452:1999 p.4.4.3.1;4.4.3.18;5.3
PN-M–34452:1999 p. 4.2.7
PN-M–34452:1999 p. 4.3.8; 4.4.3.12
PN-M–34452:1999 p. 4.4.3.16
PN-M–34452:1999 p. 4.4.3.3; 5.6.1
PN-M–34452:1999 p. 4.4.3.4; 5.6.2
PN-M–34452:1999 p. 4.4.3.5; 5.6.3
PN-M–34452:1999 p. 4.4.3.6; 5.6.4
PN-M–34452:1999 p. 5.2
PN-M–34452:1999 p. 5.4
Procedura LGP/42/B
Procedura nr LGP/42/B wyd. 4
Zharmonizowane specyfikacje techniczne