🇵🇱 INSTYTUT ENERGETYKI – PAŃSTWOWY INSTYTUT BADAWCZY PL

PCA AB 087 • Łódź, Poland • 491 methods

Petrochemistry & fuelsWater & wastewaterEnvironment

INSTYTUT ENERGETYKI – PAŃSTWOWY INSTYTUT BADAWCZY is a laboratory accredited by PCA under number AB 087 (Łódź, Poland). Its accreditation scope covers 491 test methods in the following areas: Petrochemistry & fuels, Water & wastewater, Environment. Test objects include: HEATING BOILERS FOR SOLID FUELS, RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS, RESIDENTIAL SOLID FUEL BURNING APPLIANCES, RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPL…. Most frequently used techniques: Chemiluminescence method (CLD); Continuous flame ionization detecti…, Gravimetric method, Non-dispersive infrared spectrometry (NDIR).

At a glance

  • Accreditation number: PCA AB 087
  • Methods in scope: 491
  • Types of test objects: 19
  • Techniques used: 5
  • City: Łódź, Poland
Accreditation number
AB 087
Accreditation body
PCA
Address
ul. Mory 8, 01-330 Warszawa, LABORATORIUM BADAŃ KOTŁÓW I URZĄDZEŃ GRZEWCZYCH, ul. Dostawcza 1, 93-231 Łódź
City
Łódź, Poland

What this laboratory tests (19)

Analytical techniques used (5)

Laboratory locations

Accreditation scope — test methods (491)

No. Test object Methodology / Parameters Technique Reference document
Boiler and Heating Equipment Testing Laboratory
1 HEATING BOILERS FOR SOLID FUELS WATER PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
2 HEATING BOILERS FOR SOLID FUELS
temperature (0 - 100) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p.5.2; 5.7.2; 5.7.3; 5.8.2 | PN-EN 303-5:2021-09 p.5.2; 5.6.2; 5.6.3; 5.7.2; 5.7.3 | PN-EN 303-5+A1:2023-05 p. 5.2, 5.6.2, 5.6.3, 5.7.2, 5,7,3 | PN-M-34452:1999 p. 4.3.6
3 HEATING BOILERS FOR SOLID FUELS
pressure (0 - 0,6) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2 | PN-M-34452:1999 p. 5.3.7
4 HEATING BOILERS FOR SOLID FUELS
mass flow rate (0 - 80000) kg/h (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2 | PN-M-34452:1999 p. 4.3.2
5 HEATING BOILERS FOR SOLID FUELS
volume flow rate (0 - 80) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2
6 HEATING BOILERS FOR SOLID FUELS FUEL PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p. 5.2 | PN-EN 303-5:2021-09 p. 5.2 | PN-EN 303-5+A1:2023-05 p. 5.2
7 HEATING BOILERS FOR SOLID FUELS
moisture content in wood
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Procedura nr LGP/42/B wyd. 4
8 HEATING BOILERS FOR SOLID FUELS
mass flow rate (0 - 1000) kg/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p. 5.2, 5.7.3, 5.7.4 | PN-EN 303-5:2021-09 p. 5.2; 5.6.3; 5.6.4 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.3; 5.6.4 | PN-M-34452:1999 p. 4.3.3
9 HEATING BOILERS FOR SOLID FUELS
net calorific value (10 - 32) MJ/kg (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Procedura nr LGP/42/B wyd. 4
10 HEATING BOILERS FOR SOLID FUELS FURNACE WASTE:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Procedura nr LGP/42/B wyd. 4
11 HEATING BOILERS FOR SOLID FUELS
ash mass flow rate (0 - 300) kg/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-M-34452:1999 p. 4.3.3
12 HEATING BOILERS FOR SOLID FUELS
slag mass flow rate (0 - 300) kg/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-M-34452:1999 p. 4.3.3
13 HEATING BOILERS FOR SOLID FUELS FLUE GAS PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-M-34452:1999 p. 4.3.3
14 HEATING BOILERS FOR SOLID FUELS
temperature (0 - 600) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p. 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.3 | PN-EN 304:2017-11 rys.4,5,6 | PN-M-34452:1999 p. 4.3.6.3
15 HEATING BOILERS FOR SOLID FUELS
pressure (-10 - 10) hPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p. 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.3 | PN-EN 304:2017-11 rys.4,5,6 | PN-M-34452:1999 p. 4.3.6.3
16 HEATING BOILERS FOR SOLID FUELS Concentrations of carbon dioxide, carbon monoxide.
CO2; (0,5 - 16) % CO; (0,0003 - 4,0) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Non-dispersive infrared spectrometry (NDIR) PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8
17 HEATING BOILERS FOR SOLID FUELS Concentrations of nitrogen monoxide, OGC.
NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8
18 HEATING BOILERS FOR SOLID FUELS Dust concentration in flue gases
Range (0,002 - 1) g/m3
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Gravimetric method PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-M–34452:1999 p. 4.3.8; 4.4.3.12
19 HEATING BOILERS FOR SOLID FUELS AMBIENT AIR PARAMETERS AT THE TEST SITE:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9 | PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-M–34452:1999 p. 4.3.8; 4.4.3.12
20 HEATING BOILERS FOR SOLID FUELS
temperature (10-35)°C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p. 5.7.1; 5.7.3 | PN-EN 303-5:2021-09 p. 5.6.1; 5.6.3 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.3 | PN-M–34452:1999 p. 4.2.7
21 HEATING BOILERS FOR SOLID FUELS
pressure (940-1060) hPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 297:2002 p. 4.1.6.7
22 HEATING BOILERS FOR SOLID FUELS HEAT BALANCE (calculated):
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 297:2002 p. 4.1.6.7
23 HEATING BOILERS FOR SOLID FUELS
heat output (1,5 - 1000) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.8.1.1; 5.8.1.2; 5.8.2; 5.8.3; 5.10.1 | PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.7.1.1; 5.7.1.2; 5.7.2; 5.7.3; 5.9.1 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.7.1.1, 5.7.1.2, 5.7.2, 5.7.3, 5.9.1 | PN-M-34452:1999 p.4.4.3.1;4.4.3.18;5.3
24 HEATING BOILERS FOR SOLID FUELS
heat input from fuel (1,7 - 2000) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.10.2 | PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.9.2 | PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.9.2 | PN-M–34452:1999 p. 5.2
25 HEATING BOILERS FOR SOLID FUELS
verification of the nominal heat output in condensing mode
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5 +A1:2023-05 p. 5.7.4
26 HEATING BOILERS FOR SOLID FUELS
verification of the minimum heat output in condensing mode
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5 +A1:2023-05 p. 5.7.5
27 HEATING BOILERS FOR SOLID FUELS
sampling and verification of the condensate composition
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5 +A1:2023-05 p. 5.12
28 HEATING BOILERS FOR SOLID FUELS
safety of the condensation process
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5 +A1:2023-05 p. 5.17
29 HEATING BOILERS FOR SOLID FUELS
Efficiency (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 5.4
30 HEATING BOILERS FOR SOLID FUELS
stack loss (5-40) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p. 5.10.3.2 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 4.4.3.3; 5.6.1
31 HEATING BOILERS FOR SOLID FUELS
losses due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3 | PN-M–34452:1999 p. 4.4.3.4; 5.6.2
32 HEATING BOILERS FOR SOLID FUELS
loss due to incomplete combustion (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p.5.10.3 | PN-M–34452:1999 p. 4.4.3.5; 5.6.3 | PN-EN 303-5:2021-09 p. 5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3
33 HEATING BOILERS FOR SOLID FUELS
losses to the surroundings
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 304:2017-11 p. A.8.3 | PN-M–34452:1999 p. 4.4.3.6; 5.6.4 | PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3
34 HEATING BOILERS FOR SOLID FUELS TECHNICAL AND OPERATIONAL PARAMETERS OF THE BOILER:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 304:2017-11 p. A.8.3 | PN-M–34452:1999 p. 4.4.3.6; 5.6.4 | PN-EN 303-5:2012 p.5.10.3 | PN-EN 303-5:2021-09 p.5.9.3 | PN-EN 303-5+A1:2023-05 p. 5.9.3
35 HEATING BOILERS FOR SOLID FUELS
water flow resistance water pressure (10-2000) Pa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p.5.11 | PN-EN 303-5:2021-09 p.5.10 | PN-EN 303-5+A1:2023-05 p. 5.10 | PN-EN 304:2017-11 p. 6.6
36 HEATING BOILERS FOR SOLID FUELS
temperatures of external surfaces (0-200) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.11 | PN-EN 303-5+A1:2023-05 p. 5.11 | PN-M–34452:1999 p. 4.4.3.16
37 HEATING BOILERS FOR SOLID FUELS
temperatures of handles (0-200) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.11 | PN-EN 303-5+A1:2023-05 p. 5.11 | PN-M–34452:1999 p. 4.4.3.16
38 HEATING BOILERS FOR SOLID FUELS
temperature of the floor under the boiler (0-200) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-M–34452:1999 p. 4.4.3.16 | PN-EN 303-5:2012 p. 5.12 | PN-EN 303-5:2021-09 p.5.12 | PN-EN 303-5+A1:2023-05 p. 5.12 | PN-EN 304:2017-11 p. 6.15
39 HEATING BOILERS FOR SOLID FUELS
leak-tightness testing
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p. 5.6 | PN-EN 303-5:2021-09 p. 5.16.6, 5.18.1 | PN-EN 303-5 +A1:2023-05 p. 5.16.6, 5.18.1
40 HEATING BOILERS FOR SOLID FUELS OPERATION OF AUTOMATIC CONTROLS AND SAFETY DEVICES:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p. 5.6 | PN-EN 303-5:2021-09 p. 5.16.6, 5.18.1 | PN-EN 303-5 +A1:2023-05 p. 5.16.6, 5.18.1
41 HEATING BOILERS FOR SOLID FUELS
operation of the water temperature controller and the safety temperature limiter (0-110)°C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p. 5.13 | PN-EN 303-5:2021-09 p.5.13 | PN-EN 303-5+A1:2023-05 p. 5.13
42 HEATING BOILERS FOR SOLID FUELS
operation of the excess heat discharge device water temperature (0-120) °C water pressure (0,1-0,3) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p. 5.15 | PN-EN 303-5:2021-09 p. 5.15 | PN-EN 303-5+A1:2023-05 p. 5.15
43 HEATING BOILERS FOR SOLID FUELS
operation of fast switch-off systems
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2012 p. 5.14 | PN-EN 303-5 +A1:2023-05 p. 5.14
44 HEATING BOILERS FOR SOLID FUELS
safety of boilers under fuel overfilling conditions and when the fuel feed is blocked
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2021-09 p. 5.16.2 | PN-EN 303-5 +A1:2023-05 p. 5.16.2
45 HEATING BOILERS FOR SOLID FUELS
safety of boilers in the event of air supply failure
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2021-09 p. 5.16.3 | PN-EN 303-5 +A1:2023-05 p. 5.16.3
46 HEATING BOILERS FOR SOLID FUELS
safety of boilers with respect to heat conduction
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2021-09 p. 5.16.4 | PN-EN 303-5 +A1:2023-05 p. 5.16.4
47 SOLID FUEL LOCAL SPACE HEATERS FUEL PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2021-09 p. 5.16.4 | PN-EN 303-5 +A1:2023-05 p. 5.16.4
48 SOLID FUEL LOCAL SPACE HEATERS
moisture content in wood (10-50) % net calorific value (10-32) MJ/kg (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Procedura nr LGP/42/B wyd. 4
49 SOLID FUEL LOCAL SPACE HEATERS
fuel mass (0,1-300) kg
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.4.2
50 SOLID FUEL LOCAL SPACE HEATERS FLUE GAS PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.4.2
51 SOLID FUEL LOCAL SPACE HEATERS
temperature (15-1100) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.4.4.3
52 SOLID FUEL LOCAL SPACE HEATERS
pressure (-10 - 10) hPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A2.3.4; A.4
53 SOLID FUEL LOCAL SPACE HEATERS Concentrations of carbon dioxide, carbon monoxide.
CO2; (0,5-16) % CO; (0,0003-4,0) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Non-dispersive infrared spectrometry (NDIR) PN-EN 13240:2008 p. A.4.4.2
54 SOLID FUEL LOCAL SPACE HEATERS Concentrations of nitrogen monoxide, OGC.
NO; (5 - 440) mg/m3 OGC; (3,5-1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8
55 SOLID FUEL LOCAL SPACE HEATERS
dust concentration in flue gases (0,002-1) g/m3
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Gravimetric method PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8
56 SOLID FUEL LOCAL SPACE HEATERS AIR PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8
57 SOLID FUEL LOCAL SPACE HEATERS
temperature (10 - 35) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.4.4.3
58 SOLID FUEL LOCAL SPACE HEATERS WATER PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.4.4.3
59 SOLID FUEL LOCAL SPACE HEATERS
temperature (10 - 100)°C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.4.5.2
60 SOLID FUEL LOCAL SPACE HEATERS
volume flow rate (0 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.4.5.2
61 SOLID FUEL LOCAL SPACE HEATERS HEAT BALANCE (calculated):
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.4.5.2
62 SOLID FUEL LOCAL SPACE HEATERS
heat input from fuel (3 - 60) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.6.2.2
63 SOLID FUEL LOCAL SPACE HEATERS
stack loss (5 - 40) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.6.2.1.1
64 SOLID FUEL LOCAL SPACE HEATERS
losses due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.6.2.1.2
65 SOLID FUEL LOCAL SPACE HEATERS
loss due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.6.2.1.3
66 SOLID FUEL LOCAL SPACE HEATERS
thermal efficiency (20 - 95) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.6.2.1
67 SOLID FUEL LOCAL SPACE HEATERS
total heat output (3 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.6.2.2
68 SOLID FUEL LOCAL SPACE HEATERS
heat output of the water circuit (3 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.6.2.3
69 SOLID FUEL LOCAL SPACE HEATERS
heat output to the room (3 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.6.2.4
70 SOLID FUEL LOCAL SPACE HEATERS
CO content (O2=13%) (0 - 4)%
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.6.2.6
71 SOLID FUEL LOCAL SPACE HEATERS TECHNICAL AND OPERATIONAL PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.6.2.6
72 SOLID FUEL LOCAL SPACE HEATERS
temperature of the measuring corner and the floor (0 - 200) °C temperature of the fuel hopper (0 - 200) °C temperature of handles (0 - 200) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.4.7; A.4.8; A.4.9
73 SOLID FUEL LOCAL SPACE HEATERS
tightness of the water space (0,1 - 0,6) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.4.9.4
74 SOLID FUEL LOCAL SPACE HEATERS
thermal outlet safety device water temperature (0 - 120) °C water pressure (0,1 - 0,3) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.4.9.5
75 SOLID FUEL FIREPLACE INSERTS FUEL PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13240:2008 p. A.4.9.5
76 SOLID FUEL FIREPLACE INSERTS
moisture content in wood ( 10 - 50) % net calorific value (10 - 32) MJ/kg (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Procedura nr LGP/42/B wyd. 4
77 SOLID FUEL FIREPLACE INSERTS
fuel mass (0,1 - 300) kg
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.4.2
78 SOLID FUEL FIREPLACE INSERTS FLUE GAS PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.4.2
79 SOLID FUEL FIREPLACE INSERTS
temperature (0 - 600) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.4.4.3
80 SOLID FUEL FIREPLACE INSERTS
pressure (-10 - 10) hPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A2.3.4;A.4
81 SOLID FUEL FIREPLACE INSERTS Concentrations of carbon dioxide, carbon monoxide.
CO2; (0,5 - 16) % CO; (0,0003 - 4,0) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Non-dispersive infrared spectrometry (NDIR) PN-EN 13229:2002 p. A.4.4.2
82 SOLID FUEL FIREPLACE INSERTS Concentrations of nitrogen monoxide, OGC.
NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8
83 SOLID FUEL FIREPLACE INSERTS Dust concentration in flue gases
Range (0,002 - 1) g/m3
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Gravimetric method PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8
84 SOLID FUEL FIREPLACE INSERTS AIR PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8
85 SOLID FUEL FIREPLACE INSERTS
temperature (10 - 35) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.4.4.3
86 SOLID FUEL FIREPLACE INSERTS WATER PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.4.4.3
87 SOLID FUEL FIREPLACE INSERTS
temperature (0 - 100) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.4.5.2
88 SOLID FUEL FIREPLACE INSERTS
volume flow rate (0 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.4.5.2
89 SOLID FUEL FIREPLACE INSERTS HEAT BALANCE (calculated):
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.4.5.2
90 SOLID FUEL FIREPLACE INSERTS
heat input from fuel (3 - 60) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.6.2.2
91 SOLID FUEL FIREPLACE INSERTS
stack loss (5 - 40) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.6.2.1.1
92 SOLID FUEL FIREPLACE INSERTS
losses due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.6.2.1.2
93 SOLID FUEL FIREPLACE INSERTS
loss due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.6.2.1.3
94 SOLID FUEL FIREPLACE INSERTS
thermal efficiency (20 - 95) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.6.2.1
95 SOLID FUEL FIREPLACE INSERTS
total heat output (3 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.6.2.2
96 SOLID FUEL FIREPLACE INSERTS
heat output of the water circuit (0 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.6.2.3
97 SOLID FUEL FIREPLACE INSERTS
heat output to the room (3 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.6.2.4
98 SOLID FUEL FIREPLACE INSERTS
CO content (O2=13%) (0 - 4) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.6.2.6
99 SOLID FUEL FIREPLACE INSERTS TECHNICAL AND OPERATIONAL PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.6.2.6
100 SOLID FUEL FIREPLACE INSERTS
temperature of the measuring corner and the floor (0 - 200) °C temperature of the fuel hopper (0 - 200)°C temperature of handles (0 - 200) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.4.7; A.4.8; A.4.9
101 SOLID FUEL FIREPLACE INSERTS
tightness of the water space (0,1 - 0,6) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.4.9.5
102 SOLID FUEL FIREPLACE INSERTS
thermal outlet safety device water temperature (0 - 120) °C water pressure (0,1 - 0,3) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.4.9.6
103 SOLID FUEL COOKERS FUEL PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 13229:2002 p. A.4.9.6
104 SOLID FUEL COOKERS
moisture content in wood net calorific value (10 - 32) MJ/kg (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Procedura nr LGP/42/B wyd. 4
105 SOLID FUEL COOKERS
fuel mass (0,1 - 300) kg
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.4.2
106 SOLID FUEL COOKERS FLUE GAS PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.4.2
107 SOLID FUEL COOKERS
temperature (0 - 600) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.2.3.2; A.4.4.3
108 SOLID FUEL COOKERS
pressure (-10 - 10) hPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.2.3.4.
109 SOLID FUEL COOKERS Concentrations of carbon dioxide, carbon monoxide.
CO2; (0,5 - 16) % CO; (0,0003 - 4,0) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Non-dispersive infrared spectrometry (NDIR) PN-EN 12815:2004 p. A.2.3; A.4.4.2
110 SOLID FUEL COOKERS Concentrations of nitrogen monoxide, OGC.
NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8
111 SOLID FUEL COOKERS Dust concentration in flue gases
Range (0,005 - 1) g/m3
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Gravimetric method PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8
112 SOLID FUEL COOKERS AIR PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8
113 SOLID FUEL COOKERS
temperature (10 - 35) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.1.1; A.4.4.3
114 SOLID FUEL COOKERS WATER PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.1.1; A.4.4.3
115 SOLID FUEL COOKERS
temperature (0 - 100) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.2.5; A.4.5
116 SOLID FUEL COOKERS
volume flow rate (0 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.2.5; A.4.5
117 SOLID FUEL COOKERS HEAT BALANCE (calculated):
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.2.5; A.4.5
118 SOLID FUEL COOKERS
heat input from fuel (3 - 60) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.4.5; A.4.9; A.4.12; A.6.2.2
119 SOLID FUEL COOKERS
stack loss (5 - 40) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.4.4; A.6.2.1.1
120 SOLID FUEL COOKERS
losses due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.4.4; A.6.2.1.2
121 SOLID FUEL COOKERS
loss due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.4.6; A.6.2.1.3
122 SOLID FUEL COOKERS
thermal efficiency (20 - 95) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.6.2.1
123 SOLID FUEL COOKERS
total heat output (3 - 50)kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.6.2.2
124 SOLID FUEL COOKERS
heat output of the water circuit (0 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.6.2.3
125 SOLID FUEL COOKERS
heat output to the room (3 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.6.2.4
126 SOLID FUEL COOKERS
CO content (O2=13%) (0 - 4) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.6.2.6
127 SOLID FUEL COOKERS TECHNICAL AND OPERATIONAL PARAMETERS
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.6.2.6
128 SOLID FUEL COOKERS
temperature of the measuring corner and the floor (0 - 200) °C temperature of the fuel hopper (0 - 200)°C temperature of handles (0 - 200) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.4.7; A.4.10; A.4.12; A.4.16
129 SOLID FUEL COOKERS
tightness of the water space (0,1 - 0,6) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.4.17
130 SOLID FUEL COOKERS
thermal outlet safety device water temperature (0 - 120) °C water pressure (0,1 - 0,3) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.4.18
131 SOLID FUEL COOKERS
boiling, water temperature (0 - 100) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.4.10
132 SOLID FUEL COOKERS
baking, air temperature (0 - 300) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.4.11
133 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW FUEL PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12815:2004 p. A.4.11
134 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW
moisture content in wood (10 - 50) % net calorific value (10 - 32) MJ/kg (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Procedura nr LGP/42/B wyd. 4
135 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW
fuel mass (0,1 - 300) kg
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A3.
136 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW FLUE GAS PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A3.
137 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW
temperature (0 - 600) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.2.3.2
138 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW
pressure (-10 - 10) hPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.2.3.4; A4
139 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Concentrations of carbon dioxide, carbon monoxide.
CO2; (0,5 - 16) % CO; (0,0003 - 4,0) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Non-dispersive infrared spectrometry (NDIR) PN-EN 12809:2002 p. A.2.3.3
140 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Concentrations of nitrogen monoxide, OGC.
NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8
141 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW Dust concentration in flue gases
Range (0,005 - 1) g/m3
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Gravimetric method PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8
142 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW AIR PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8
143 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW
temperature (10 - 35) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.1.1.
144 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW WATER PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.1.1.
145 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW
temperature (10 - 100)°C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.2.5
146 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW
volume flow rate (0 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.2.5.
147 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW HEAT BALANCE (calculated):
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.2.5.
148 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW
heat input from fuel (5 - 100) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.6.2.2
149 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW
stack loss (5 - 40) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.6.2.1.1
150 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW
losses due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.6.2.1.2
151 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW
loss due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.6.2.1.3
152 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW
thermal efficiency (20 - 95) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.6.2.1
153 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW
total heat output (5 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.6.2.2
154 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW
heat output of the water circuit (5 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.6.2.3.
155 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW
heat output to the room (5 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.6.2.4
156 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW
CO content (O2=13%) (0 - 4) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.6.2.6
157 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW TECHNICAL AND OPERATIONAL PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.6.2.6
158 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW
temperature of the measuring corner and the floor (0 - 200) °C temperature of the fuel hopper (0 - 200) °C temperature of handles (0 - 200) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.2; A.3
159 HEATING BOILERS FOR SOLID FUELS WITH NOMINAL HEAT OUTPUT UP TO 50 kW
tightness of the water space (0,1 - 0,6) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.4.10
160 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS FUEL PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 12809:2002 p. A.4.10
161 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS
moisture content in wood ( 10 - 50) % net calorific value (10 - 32) MJ/kg (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Procedura nr LGP/42/B wyd. 4
162 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS
fuel mass (0,1 - 300) kg
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 15250:2009 A3; A4.2
163 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS FLUE GAS PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 15250:2009 A3; A4.2
164 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS
temperature (0 - 600) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 15250:2009 p. A2.3.2; A4.4.3
165 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS
pressure (-10 - 10) hPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 15250:2009 p. A2.3.4; A4
166 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Concentrations of carbon dioxide, carbon monoxide.
CO2; (0,5 - 16) % CO; (0,0003 - 4,0) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Non-dispersive infrared spectrometry (NDIR) PN-EN 15250:2009 p. A2.3.3; A4.4.2
167 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Concentrations of nitrogen monoxide, OGC.
NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8
168 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS Dust concentration in flue gases
Range (0,005 - 1) g/m3
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Gravimetric method PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8
169 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS AIR PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8
170 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS
temperature (10 - 35) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 15250:2009 p. A1.1; A4.4.3
171 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS HEAT BALANCE (calculated):
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 15250:2009 p. A1.1; A4.4.3
172 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS
heat energy supplied with the fuel (10 - 600) MJ
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 15250:2009 p. A6.2.2
173 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS
stack loss (5 - 40) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 15250:2009 p. A6.2.1.2
174 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS
losses due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 15250:2009 p. A6.2.1.3
175 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS
loss due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 15250:2009 p. A6.2.1.4
176 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS
thermal efficiency (20 - 95) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 15250:2009 p. A6.2.1.1
177 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS
heat output (10 - 600) MJ
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 15250:2009 p. A6.2.2
178 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS
flue gas mass flow (5 - 100) g/s
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 15250:2009 p. A6.2.3
179 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS
CO content (O2=13%) (0-4)%
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 15250:2009 p. A6.2.4
180 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS
mean temperature difference between the heater surface and the surroundings (0 - 200) K
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 15250:2009 p. A6.2.7
181 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS TECHNICAL AND OPERATIONAL PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 15250:2009 p. A6.2.7
182 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS
surface temperature of the storage heater (0 - 200) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 15250:2009 p. A2.5; A4.6
183 SOLID FUEL HEAT STORAGE LOCAL SPACE HEATERS
temperature of the measuring corner and the floor (0 - 200) °C temperature of the fuel hopper (0 - 200) °C temperature of handles (0 - 200) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 15250:2009 p. A2.2; A4.6; A4.7
184 PELLET-FIRED LOCAL SPACE HEATERS FUEL PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 15250:2009 p. A2.2; A4.6; A4.7
185 PELLET-FIRED LOCAL SPACE HEATERS
moisture content in wood (0 - 50) % net calorific value (10 - 32) MJ/kg (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Procedura nr LGP/42/B wyd. 4
186 PELLET-FIRED LOCAL SPACE HEATERS
fuel mass (0,1 - 300) kg
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A3; A 4.2
187 PELLET-FIRED LOCAL SPACE HEATERS -sampling and preparation of samples for analysis
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Procedura LGP/42/B
188 PELLET-FIRED LOCAL SPACE HEATERS FLUE GAS PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Procedura LGP/42/B
189 PELLET-FIRED LOCAL SPACE HEATERS
temperature (0 - 600) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A2.3.2; A4.4.3
190 PELLET-FIRED LOCAL SPACE HEATERS
pressure (-10 - 10) hPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A2.3.4; A4
191 PELLET-FIRED LOCAL SPACE HEATERS Concentrations of carbon dioxide, carbon monoxide.
CO2; (0,5-16) % CO; (0,0003-4,0) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Non-dispersive infrared spectrometry (NDIR) PN-EN 14785:2009 p. A2.3.3; 4.4.2
192 PELLET-FIRED LOCAL SPACE HEATERS Concentrations of nitrogen monoxide, OGC.
NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8
193 PELLET-FIRED LOCAL SPACE HEATERS Dust concentration in flue gases
Range (0,002 - 1) g/m3
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Gravimetric method PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8
194 PELLET-FIRED LOCAL SPACE HEATERS AIR PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8 | PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8
195 PELLET-FIRED LOCAL SPACE HEATERS
temperature (10 - 35) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A1.1; A4.4.3
196 PELLET-FIRED LOCAL SPACE HEATERS WATER PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A1.1; A4.4.3
197 PELLET-FIRED LOCAL SPACE HEATERS
temperature (10 - 100) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A2.5; A4.5
198 PELLET-FIRED LOCAL SPACE HEATERS
volume flow rate (0 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A2.5; A4.5
199 PELLET-FIRED LOCAL SPACE HEATERS HEAT BALANCE (calculated):
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A2.5; A4.5
200 PELLET-FIRED LOCAL SPACE HEATERS
heat input from fuel (3 - 60) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A6.2.2
201 PELLET-FIRED LOCAL SPACE HEATERS
stack loss (5 - 40) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A6.2.1.1
202 PELLET-FIRED LOCAL SPACE HEATERS
losses due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A6.2.1.2
203 PELLET-FIRED LOCAL SPACE HEATERS
loss due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A6.2.1.3
204 PELLET-FIRED LOCAL SPACE HEATERS
thermal efficiency (20 - 95) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A6.2.1
205 PELLET-FIRED LOCAL SPACE HEATERS
total heat output (3 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A6.2.2
206 PELLET-FIRED LOCAL SPACE HEATERS
heat output of the water circuit (3 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A6.2.3
207 PELLET-FIRED LOCAL SPACE HEATERS
heat output to the room (3 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A6.2.4
208 PELLET-FIRED LOCAL SPACE HEATERS
flue gas mass flow (5 - 100) g/s
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A6.2.5
209 PELLET-FIRED LOCAL SPACE HEATERS
CO content (O2=13%) (0 - 4)%
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A6.2.6
210 PELLET-FIRED LOCAL SPACE HEATERS TECHNICAL AND OPERATIONAL PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A6.2.6
211 PELLET-FIRED LOCAL SPACE HEATERS
temperature of the measuring corner and the floor (0 - 200) °C temperature of the fuel hopper (0 - 200) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A2.2; A4.7; A4.8; A4.9
212 PELLET-FIRED LOCAL SPACE HEATERS
temperature of handles (0 - 200) °C
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A2.2; A4.7; A4.8; A4.9
213 PELLET-FIRED LOCAL SPACE HEATERS
tightness of the water space (0,1 - 0,6) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A4.9.2
214 PELLET-FIRED LOCAL SPACE HEATERS
thermal outlet safety device water temperature (0 - 120) °C water pressure (0,1 - 0,3) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 14785:2009 p. A4.9.3
215 HEATING BOILERS FOR SOLID FUELS Measurement of electric energy consumption
Range (2 - 4000) W
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Method: power transducers PN-EN 303-5:2021-09 p. 5.7.7 | PN-EN 303-5+A1:2023-05 p. 5.7.7
216 RESIDENTIAL SOLID FUEL BURNING APPLIANCES FUEL PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 303-5:2021-09 p. 5.7.7 | PN-EN 303-5+A1:2023-05 p. 5.7.7
217 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
moisture content in wood (10 - 50) % net calorific value (10 - 32) MJ/kg (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Procedura nr LGP/42/B wyd. 4
218 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
fuel mass (0,1 - 300) kg
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.4.2
219 RESIDENTIAL SOLID FUEL BURNING APPLIANCES FLUE GAS PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.4.2
220 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
temperature (15 - 1100) oC
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 A.4.4.3, A.6.2
221 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
pressure (-10 - 10) hPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.2.3.4
222 RESIDENTIAL SOLID FUEL BURNING APPLIANCES Concentrations of carbon dioxide, carbon monoxide.
CO2; (0,5 - 16) % CO; (0,0003 - 4,0) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Non-dispersive infrared spectrometry (NDIR) PN-EN 16510-1:2023-06 p. A.4.4.2, A.3
223 RESIDENTIAL SOLID FUEL BURNING APPLIANCES Concentrations of nitrogen monoxide, OGC.
NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E
224 RESIDENTIAL SOLID FUEL BURNING APPLIANCES Dust concentration in flue gases (0,002 - 1) g/m3
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Gravimetric method PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F
225 RESIDENTIAL SOLID FUEL BURNING APPLIANCES AIR PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F
226 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
temperature (10 - 35) oC
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.4.4.3
227 RESIDENTIAL SOLID FUEL BURNING APPLIANCES WATER PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.4.4.3
228 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
temperature (10 - 100) oC
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
229 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
volume flow rate (0 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
230 RESIDENTIAL SOLID FUEL BURNING APPLIANCES HEAT BALANCE (calculated):
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
231 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
heat input from fuel (3 - 60) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.2
232 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
stack loss (5 - 40) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.2
233 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
losses due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.3
234 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
loss due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.4
235 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
thermal efficiency (20 - 95) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1
236 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
total heat output (2 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.2
237 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
heat output of the water circuit (1,5 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.3
238 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
heat output to the room (2 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.4
239 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
CO content (O2=13%) (0 - 4) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.6
240 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
flue gas mass flow (1-100) g/s (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 6.12
241 RESIDENTIAL SOLID FUEL BURNING APPLIANCES TECHNICAL AND OPERATIONAL PARAMETERS
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 6.12
242 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
temperature of the measuring corner and the floor (0 - 200) oC temperature of the fuel hopper (0 - 200) oC temperature of handles (0 - 200) oC
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6,
243 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
tightness of the water space (0,1 - 0,6) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.10.6
244 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
thermal outlet safety device water temperature (0 - 120) oC
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.10.7
245 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
water pressure (0,1 - 0,3) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.10.7
246 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
tightness (5 - 75) Pa; (0,2 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5
247 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
tightness related to CO emission (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p 5.9.1
248 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
constant air loss (1)Pa; (0 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 Załącznik I
249 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
measurement of electricity consumption (2 - 4000) W, method: power transducers
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p 6.11
250 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
temperature safety test
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.4
251 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
safety test under natural draught
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.5
252 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
operation of the safety temperature limiter (0 - 110) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-2-6:2023-06 p A.4.10.601.1 „N“ | PN-EN 16510-1:2023-06 p A.4.10.7
253 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
loss of electrical power supply (0 - 110) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-2-6:2023-06 p A.4.10.601.2 „N“ | PN-EN 16510-1:2023-06 p A.4.10.7
254 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
loss of heat removal (0 - 110) oC, (0 - 5) % CO
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.3 „N“
255 RESIDENTIAL SOLID FUEL BURNING APPLIANCES
efficiency (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6
256 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS FUEL PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6
257 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
moisture content in wood (10 - 50) % net calorific value (10 - 32) MJ/kg (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Procedura nr LGP/42/B wyd. 4
258 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
fuel mass (0,1 - 300) kg
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.4.2
259 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS FLUE GAS PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.4.2
260 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
temperature (15 - 1100) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-1:2023-06 p. 4.7.2,4.7.3, 4.7.8 „N“
261 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
pressure (-10 - 10) hPa
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-1:2023-06 p. 4.7.3, 4.7.4, 4.7.5 „N“
262 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Concentrations of carbon dioxide, carbon monoxide. Range:
CO2; (0,5 - 16) % CO; (0,0003 - 4,0) %
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Non-dispersive infrared spectrometry (NDIR) PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-1:2023-06 p. 4.3 „N“
263 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Nitrogen monoxide, OGC concentrations
NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“
264 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS Dust concentration in flue gases (0,002 - 1) g/m3
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Gravimetric method PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N“
265 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS AIR PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-1:2023-06 p. 4.6 „N“
266 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
temperature (10 - 35) oC
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.4.3
267 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS WATER PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.4.3
268 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
temperature (10 - 100) oC
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
269 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
volume flow rate (0 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
270 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS HEAT BALANCE (calculated):
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
271 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
heat input from fuel (3 - 60) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.2
272 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
stack loss (5 - 40) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.2
273 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
losses due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.3
274 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
loss due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.4
275 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
thermal efficiency (20 - 95) %
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-1:2023-06 p. 4.8.3, 4.8.6 „N“
276 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
total heat output (2 - 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-1:2023-06 p. 4.8.1, 4.8.4 „N“
277 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
heat output of the water circuit (1,5 - 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-1:2023-06 p. 4.8.2, 4.8.5 „N“
278 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
heat output to the room (2 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.4
279 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
CO content (O2=13%) (0 - 4)%
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.6
280 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
flue gas mass flow (1 - 100) g/s (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“
281 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS TECHNICAL AND OPERATIONAL PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“
282 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
temperature of the measuring corner and the floor (0 - 200) oC temperature of the fuel hopper (0 - 200) oC temperature of handles (0 - 200) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 „ | PN-EN 16510-2-1:2023-06 p. 5.5, 5.6 „N“
283 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
tightness of the water space (0,1 - 0,6) MPa
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-1:2023-06 p. 5.3 „N“
284 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
thermal outlet safety device water temperature (0 - 120) oC water pressure (0,1 - 0,3) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.7
285 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
tightness (5 - 75)Pa; (0,2 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5
286 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
tightness related to CO emission (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p 5.9.1
287 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
constant air loss (1) Pa; (0 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 Załącznik I
288 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
measurement of electrical energy consumption (2 - 4000) W power transducer method
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-1:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“
289 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
temperature safety test
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.4
290 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
safety test under natural draught
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.5
291 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
load-bearing capacity
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.2
292 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS
efficiency (calculated) seasonal space heating efficiency (calculated) energy efficiency index EEI (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N“
293 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES FUEL PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N“
294 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
moisture content in wood (10 - 50) % net calorific value (10 - 32) MJ/kg (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Procedura nr LGP/42/B wyd. 4
295 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
fuel mass (0,1 - 300) kg
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.4.2
296 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES FLUE GAS PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.4.2
297 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
temperature (15 - 600) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-2:2023-06 p. 4.6.2,4.6.3 „N“
298 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
pressure (-10 - 10) hPa
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-2:2023-06 p. 4.6.4, 4.6.5„N“
299 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Concentrations of carbon dioxide, carbon monoxide.
CO2 (0,5 - 16) % CO (0,0003 - 4,0) %
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Non-dispersive infrared spectrometry (NDIR) PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-2:2023-06 p. 4.2 „N“
300 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Concentrations of nitrogen monoxide, OGC.
NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“
301 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES Dust concentration in flue gases (0,002 - 1) g/m3
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Gravimetric method PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N“
302 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES AIR PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-2:2023-06 p. 4.5 „N“
303 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
temperature (10 - 35) oC
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.4.3
304 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES WATER PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.4.3
305 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
temperature (10 -1 00) oC
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
306 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
volume flow rate (0 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
307 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES HEAT BALANCE (calculated):
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
308 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
heat input from fuel (3 - 60) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.2
309 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
stack loss (5 - 40) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.2
310 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
losses due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.3
311 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
loss due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.4
312 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
thermal efficiency (20 - 95) %
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-2:2023-06 p. 4.7.3, 4.7.6 „N“
313 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
total heat output (2 - 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-2:2023-06 p. 4.7.1, 4.7.4 „N“
314 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
heat output of the water circuit (1,5 - 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-2:2023-06 p. 4.7.2, 4.7.5 „N“
315 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
heat output to the room (2 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.4
316 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
CO content (O2=13%) (0 - 4)%
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.6
317 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
flue gas mass flow (1 - 100) g/s (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N“
318 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES TECHNICAL AND OPERATIONAL PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N“
319 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
temperature of the measuring corner and the floor (0 - 200) oC temperature of the fuel hopper (0 - 200) oC temperature of handles (0 - 200) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-2:2023-06 p. 5.5, 5.6 „N“
320 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
tightness of the water space (0,1 - 0,6) MPa
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-2:2023-06 p. 5.3.3 „N“
321 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
thermal outlet safety device water temperature (0 - 120) oC water pressure (0,1 - 0,3) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.7
322 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
tightness (5 - 75) Pa; (0,2 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5
323 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
tightness related to CO emission (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p 5.9.1
324 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
constant air loss (1)Pa; (0 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 Załącznik I
325 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
measurement of electrical energy consumption (2 - 4000) W
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Power transducer method PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-2:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N“
326 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
temperature safety test
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.4
327 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
safety test under natural draught
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.5
328 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - INSET APPLIANCES, INCLUDING OPEN FIRES
efficiency (calculated) seasonal space heating efficiency (calculated) energy efficiency index EEI (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N“
329 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING FUEL PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N“
330 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
moisture content in wood (10 - 50) % net calorific value (10 - 32) MJ/kg (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Procedura nr LGP/42/B wyd. 4
331 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
fuel mass (0,1 - 300) kg
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.4.2
332 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING FLUE GAS PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.4.2
333 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
temperature (15 - 600) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-6:2023-06 p. 4.7.2,4.7.3 „N“
334 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
pressure (-10 - 10) hPa
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-6:2023-06 p. 4.7.4, 4.7.5 „N“
335 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Concentrations of carbon dioxide, carbon monoxide. Range:
CO2; (0,5 - 16) % CO; (0,0003 - 4,0) %
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Non-dispersive infrared spectrometry (NDIR) PN-EN 16510-1:2023-06 p. A.4.4.2, A. | PN-EN 16510-2-6:2023-06 p. 4.3 „N“
336 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Concentrations of nitrogen monoxide, OGC.
NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N“
337 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING Dust concentration in flue gases (0,002 - 1) g/m3
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Gravimetric method PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N“
338 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING AIR PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-6:2023-06 p. 4.6 „N“
339 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
temperature (10-35) oC
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.4.3
340 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING WATER PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.4.3
341 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
temperature (10 - 100) oC
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
342 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
volume flow rate (0 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
343 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING HEAT BALANCE (calculated):
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
344 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
heat input from fuel (3 - 60) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.2
345 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
stack loss (5 - 40) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.2
346 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
losses due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.3
347 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
loss due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.4
348 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
thermal efficiency (20 - 95) %
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-6:2023-06 p. 4.8.3, 4.8.6 „N“
349 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
total heat output (2 - 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-6:2023-06 p. 4.8.1, 4.8.4 „N“
350 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
heat output of the water circuit (1,5 - 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-6:2023-06 p. 4.8.2, 4.8.5 „N“
351 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
heat output to the room (2 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.4
352 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
CO content (O2=13%) (0 - 4)%
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.6
353 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
flue gas mass flow (1 - 100) g/s (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N“
354 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING TECHNICAL AND OPERATIONAL PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N“
355 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
temperature of the measuring corner and the floor (0 - 200) oC temperature of the fuel hopper (0 - 200) oC temperature of handles (0 - 200) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-6:2023-06 p. 5.5.1, 5.5.2, 5.6 „N“
356 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
tightness of the water space (0,1 - 0,6) MPa
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-6:2023-06 p. 5.3.3 „N“
357 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
thermal outlet safety device water temperature (0 - 120) oC water pressure (0,1 - 0,3) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.7
358 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
tightness (5 - 75) Pa; (0,2 - 3) m3/h
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5 | PN-EN 16510-2-6:2023-06 p 5.1.2, 5.1.3 „N“
359 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
tightness related to CO emission (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p 5.9.1
360 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
constant air loss (1)Pa; (0 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 Załącznik I
361 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
measurement of electrical energy consumption (2 - 4000) W
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Power transducer method PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-6:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“
362 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
temperature safety test
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.4
363 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
safety test under natural draught
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.5
364 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
operation of the safety temperature limiter (0 - 110) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.1„N“
365 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
loss of electrical power supply (0 - 110) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.2 „N“
366 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
loss of heat removal (0 - 110) oC, (0 - 5) % CO
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-6:2023-06 p A.4.10.601.3 „N“
367 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
load-bearing capacity
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.2
368 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - ROOMHEATERS, INSET APPLIANCES, AND COOKERS, WITH MECHANICAL WOOD PELLET FEEDING
efficiency (calculated), seasonal space heating efficiency (calculated) energy efficiency index EEI (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N“
369 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS FUEL PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N“
370 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
moisture content in wood ( 10 - 50) % net calorific value (10 - 32) MJ/kg (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Procedura nr LGP/42/B wyd. 4
371 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
fuel mass (0,1 - 300) kg
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.4.2
372 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS FLUE GAS PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.4.2
373 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
temperature (15 - 600) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-3:2023-06 p. 4.6.2,4.6.3 „N”
374 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS pressure (-10 - 10) hPa
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”
375 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Concentrations of carbon dioxide, carbon monoxide. Range:
CO2 (0,5 - 16) % CO (0,0003 - 4,0) %
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Non-dispersive infrared spectrometry (NDIR) PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”
376 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Concentrations of nitrogen monoxide, OGC.
NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-3:2023-06 p. 4.3, 4.4, „N”
377 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS Dust concentration in flue gases (0,002 - 1) g/m3
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Gravimetric method PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”
378 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS AIR PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-3:2023-06 p. 4.5 „N”
379 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
air temperature (10 - 35) oC
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.4.3
380 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS WATER PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.4.3
381 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
water temperature (10 - 100) oC
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
382 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
water volume flow rate (0 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
383 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS HEAT BALANCE:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
384 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
heat input from fuel (3 - 60) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.2
385 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
stack loss (5 - 40) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.
386 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
losses due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.3
387 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
loss due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.4
388 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
thermal efficiency (20 - 95) %
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-3:2023-06 p. 4.7.3, 4.7.6 „N”
389 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
total heat output (2 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.2
390 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
heat output of the water circuit (1,5 - 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-3:2023-06 p. 4.7.2, 4.7.5 „N”
391 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
heat output to the room (2 - 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.6.2.4 | PN-EN 16510-2-3:2023-06 p. 4.7.1, 4.7.4 „N”
392 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
flue gas mass flow (1 - 100) g/s (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”
393 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS TECHNICAL AND OPERATIONAL PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”
394 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
temperature of the measuring corner and the floor (0 - 200) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.6 | PN-EN 16510-2-3:2023-06 p.4.1 „N”
395 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
temperature of the fuel hopper (0 - 200) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4 | PN-EN 16510-2-3:2023-06 p. 5.5 „N”
396 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS TECHNICAL AND OPERATIONAL PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4 | PN-EN 16510-2-3:2023-06 p. 5.5 „N”
397 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
temperature of handles (0 - 200) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.5 | PN-EN 16510-2-3:2023-06 p.5.6 „N”
398 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
tightness of the water space (0,1 - 0,6) MPa
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-3:2023-06 p. 5.9 „N”
399 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
thermal outlet safety device water temperature (0 - 120) oC water pressure (0,1 - 0,3) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.7
400 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
tightness (5 - 75) Pa; (0,2 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5
401 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
tightness related to CO emission (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p 5.9.1
402 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
constant air loss (1) Pa; (0 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 Załącznik I
403 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
measurement of electrical energy consumption (2 - 4000) W
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Power transducer method PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-3:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”
404 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
temperature safety test
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.4
405 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
safety test under natural draught
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.5
406 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
efficiency (calculated), seasonal space heating efficiency (calculated), EEI (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-3:2023-06 p. 4.7.7, 4.7.8 „N”
407 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
measurement of oven temperature, air temperature (0 - 300) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-2-3:2023-06 A.4.301.1 „N”
408 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
boiling test on a hotplate, water temperature (0 - 100) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-2-3:2023-06 A.4.301.2 „N”
409 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - COOKERS
baking, air temperature (0 - 300) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-2-3:2023-06 A.4.301.3 „N”
410 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES FUEL PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-2-3:2023-06 A.4.301.3 „N”
411 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
moisture content in wood (10 - 50) % net calorific value (10 - 32) MJ/kg (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Procedura nr LGP/42/B wyd. 4
412 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
fuel mass (0,1 - 300) kg
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.4.2
413 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES FLUE GAS PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.4.2
414 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
temperature (15 - 1100) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 A.4.4.3, A.6.2, 6.2.1 | PN-EN 16510-2-5:2025-10 p. 4.7.2,4.7.5 „N“
415 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
pressure (-10 - 10) hPa
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.2.3.4, 6.5 | PN-EN 16510-2-5:2025-10 p. 4.7.3, 4.7.4, 4.7.5 „N“
416 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Concentrations of carbon dioxide, carbon monoxide.
CO2; (0,5 - 16) % CO; (0,0003 - 4,0) %
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Non-dispersive infrared spectrometry (NDIR) PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-5:2025-10 p. 4.3 „N“
417 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Concentrations of nitrogen monoxide, OGC.
NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-5:2025-10 p. 4.4, 4.5 „N“
418 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES Dust concentration in flue gases (0,002 - 1) g/m3
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Gravimetric method PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-5:2025-10 p. 4.6 „N“
419 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES AIR PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-5:2025-10 p. 4.6 „N“
420 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
temperature (10 - 35) oC
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.4.3
421 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES WATER PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.4.3
422 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
temperature (10 - 100) oC
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
423 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
volume flow rate (0 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
424 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES HEAT BALANCE (calculated):
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
425 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
heat input from fuel (3 - 60) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.2
426 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES -thermal energy supplied with the fuel (10-600) MJ
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-2-5:2025-10 p. A.6.2.501 „N“
427 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
stack loss (5 - 40) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.2
428 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
losses due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.3
429 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
loss due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.4
430 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
thermal efficiency (20 - 95) %
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-5:2025-10 p. 4.8.3 „N“
431 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
total heat output (2 - 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2 „N“
432 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
heat output of the water circuit (1,5 - 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-5:2025-10 p. 4.8.2, 4.8.4, A.6.2.3„N“
433 - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
heat output to the room (2 - 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.6.2.4 | PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2, A.6.2.4, A.6.2.501 „N“
434 - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
CO content (O2=13%) (0 - 4)%
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.6
435 - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
flue gas mass flow (1 - 100) g/s (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-5:2025-10 p. 4.7.4 „N“
436 - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES -mean temperature difference between the appliance surface and the surroundings (0 - 200) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-2-5:2025-10 p. 4.8.502, A.2.501, A.6.2.502 „N“
437 - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES TECHNICAL AND OPERATIONAL PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-2-5:2025-10 p. 4.8.502, A.2.501, A.6.2.502 „N“
438 - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
temperature of the measuring corner and the floor (0 - 200) oC temperature of the fuel hopper (0 - 200) oC temperature of handles (0 - 200) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 | PN-EN 16510-2-5:2025-10 p. 4.7.5, 5.5, A.4.10 „N“
439 - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
tightness of the water space (0,1 - 0,6) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.10.6
440 - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
thermal outlet safety device water temperature (0 - 120) oC water pressure (0,1 - 0,3) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.7
441 - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
tightness (5 - 75) Pa; (0,2 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5
442 - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
tightness related to CO emission (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p 5.9.1
443 - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
constant air loss (1) Pa; (0 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 Załącznik I
444 - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
measurement of electricity consumption (2 - 4000) W power transducer method
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-5:2025-10 p. 4.8.6, 4.8.7 „N“
445 - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
temperature safety test
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.4.10.4 | PN-EN 16510-2-5:2025-10 p.A.4.10.2 „N“
446 - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES -test of the operation of the heat discharge control system and of the safety heat exchanger
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-5:2025-10 p.A.4.10.7 „N“
447 - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
load-bearing capacity
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.2
448 - RESIDENTIAL SOLID FUEL BURNING APPLIANCES - SLOW HEAT RELEASE APPLIANCES
efficiency (calculated) seasonal space heating efficiency (calculated) energy efficiency index EEI (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-5:2025-10 p. 4.8.4, 4.8.5 „N“
449 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS FUEL PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-5:2025-10 p. 4.8.4, 4.8.5 „N“
450 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
moisture content in wood (10 - 50) % net calorific value (10 - 32) MJ/kg (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
Procedura nr LGP/42/B wyd. 4
451 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
fuel mass (0,1 - 300) kg
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.4.2
452 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS FLUE GAS PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.4.2
453 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
temperature (15 - 600) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 A.4.4.3, A.6.2 | PN-EN 16510-2-7:2025-10 p. 4.7.2, 4.7.3 „N“
454 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
pressure (-10 - 10) hPa
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.2.3.4 | PN-EN 16510-2-7:2025-10 p. 4.7.4, 4.7.5„N“
455 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Concentrations of carbon dioxide, carbon monoxide.
CO2 (0,5 - 16) % CO (0,0003 - 4,0) %
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Non-dispersive infrared spectrometry (NDIR) PN-EN 16510-1:2023-06 p. A.4.4.2, A.3 | PN-EN 16510-2-7:2025-10 p. 4.3 „N“
456 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Concentrations of nitrogen monoxide, OGC.
NO (5 - 440) mg/m3 OGC (3,5 - 1800) mg/m3 Emission of CO2; CO; NO; OGC (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Chemiluminescence method (CLD); Continuous flame ionization detection method (FID) PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E | PN-EN 16510-2-7:2025-10 p. 4.4, 4.5 „N“
457 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS Dust concentration in flue gases (0,002 - 1) g/m3
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Gravimetric method PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-7:2025-10 p. 4.6 „N“
458 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS AIR PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F | PN-EN 16510-2-7:2025-10 p. 4.6 „N“
459 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
temperature (10 - 35) oC
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.4.3
460 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS WATER PARAMETERS:
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.4.3
461 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
temperature (10 -1 00) oC
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
462 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
volume flow rate (0 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
463 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS HEAT BALANCE (calculated):
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p. A.4.5.2
464 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
heat input from fuel (3 - 60) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.2
465 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
stack loss (5 - 40) %
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.2
466 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
losses due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.3
467 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
loss due to incomplete combustion
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.1.4
468 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
thermal efficiency (20 - 95) %
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.6.2.1 | PN-EN 16510-2-7:2025-10 p. 4.8.4, 4.8.7 „N“
469 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
total heat output (2 - 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.6.2.2 | PN-EN 16510-2-7:2025-10 p. 4.8.2, 4.8.5 „N“
470 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
heat output of the water circuit (1,5 - 50) kW
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.6.2.3 | PN-EN 16510-2-7:2025-10 p. 4.8.3, 4.8.6 „N“
471 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
heat output to the room (2 - 50) kW
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.4
472 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
CO content (O2=13%) (0 - 4)%
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p.A.6.2.6
473 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
flue gas mass flow (1 - 100) g/s (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-7:2025-10 p. 4.7.6, 4.7.7 „N“
474 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS TECHNICAL AND OPERATIONAL PARAMETERS:
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 6.12 | PN-EN 16510-2-7:2025-10 p. 4.7.6, 4.7.7 „N“
475 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
temperature of the measuring corner and the floor (0 - 200) oC temperature of the fuel hopper (0 - 200) oC temperature of handles (0 - 200) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10.4, 5.4, 5.5, 5.6 | PN-EN 16510-2-7:2025-10 p. 5.5.1, 5.5.3, 5.6 „N“
476 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
tightness of the water space (0,1 - 0,6) MPa
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p. A.4.10.6 | PN-EN 16510-2-7:2025-10 p. A.4.10.6 „N“
477 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
thermal outlet safety device water temperature (0 - 120) oC water pressure (0,1 - 0,3) MPa
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.7
478 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
tightness (5 - 75) Pa; (0,2 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5
479 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
tightness related to CO emission (calculated)
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p 5.9.1
480 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
constant air loss (1)Pa; (0 - 3) m3/h
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 Załącznik I
481 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
measurement of electrical energy consumption (2 - 4000) W
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
Power transducer method PN-EN 16510-1:2023-06 p 6.11 | PN-EN 16510-2-7:2025-10 p. 4.8.10, 4.8.11, 4.8.12 „N“
482 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
temperature safety test
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.4.10.4 | PN-EN 16510-2-7:2025-10 p. 4.7.8, A.4.10.4.2. „N“
483 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
operation of the temperature limiter
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.702, A.4.10.7.703 „N“
484 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
loss of electrical power supply (0 - 110) oC
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.2 „N“
485 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
loss of heat removal (0 - 110) oC, (0 - 5) % CO
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.4.10.7 | PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.1, A.4.10.7.703.1.3 „N“
486 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
load-bearing capacity
Regulated area: Conformity assessment for Regulation (EU) No 305/2011 of the European Parliament and of the Council (CPR), EC Decision: 1999/471/EC
PN-EN 16510-1:2023-06 p A.4.10.2
487 RESIDENTIAL SOLID FUEL BURNING APPLIANCES - MULTI-FUNCTION APPLIANCES FIRED BY WOOD AND PELLETS
efficiency (calculated) seasonal space heating efficiency (calculated) energy efficiency index EEI (calculated)
Regulated area: „N” – Test method used in activities relevant to notification according to Regulation (EU) No. 305/2011 of the European Parliament and of the Council of March 9, 2011.
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6, | PN-EN 16510-2-7:2025-10 p. 4.8.8, 4.8.9 „N“
488 Type of activity:
efficiency (calculated) seasonal space heating efficiency (calculated) energy efficiency index EEI (calculated)
Regulated area: The laboratory meets the requirements set out in Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, subpoint 3 of Regulation No 305/2011) in the above scope.
Dokument odniesienia:
489 ASSESSMENT OF PERFORMANCE, ON THE BASIS OF TESTING, CALCULATION, TABULATED VALUES OR DESCRIPTIVE DOCUMENTATION OF THE CONSTRUCTION PRODUCT (System 3) Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC
Regulated area: The laboratory meets the requirements set out in Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, subpoint 3 of Regulation No 305/2011) in the above scope.
Dokument odniesienia:
490 Commission decision number Product(s)
Regulated area: The laboratory meets the requirements set out in Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, subpoint 3 of Regulation No 305/2011) in the above scope.
Zharmonizowane specyfikacje techniczne
491 99/471/WE Space heaters fired with solid and liquid fuels
Regulated area: The laboratory meets the requirements set out in Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 within the scope of the activities provided for a testing laboratory (Annex V, subpoint 3 of Regulation No 305/2011) in the above scope.
EN 16510-2-1:2022 | EN 16510-2-2:2022 | EN 16510-2-3:2022 | EN 16510-2-6:2022 | EN 16510-2-5:2025 | EN 16510-2-7:2025

Reference standards (330)

Dokument odniesienia:
EN 16510-2-1:2022
EN 16510-2-2:2022
EN 16510-2-3:2022
EN 16510-2-5:2025
EN 16510-2-6:2022
EN 16510-2-7:2025
PN-EN 12809:2002 p. A.1.1.
PN-EN 12809:2002 p. A.2.3.2
PN-EN 12809:2002 p. A.2.3.3
PN-EN 12809:2002 p. A.2.3.4; A4
PN-EN 12809:2002 p. A.2.5
PN-EN 12809:2002 p. A.2.5.
PN-EN 12809:2002 p. A.2; A.3
PN-EN 12809:2002 p. A.4.10
PN-EN 12809:2002 p. A.6.2.1
PN-EN 12809:2002 p. A.6.2.1.1
PN-EN 12809:2002 p. A.6.2.1.2
PN-EN 12809:2002 p. A.6.2.1.3
PN-EN 12809:2002 p. A.6.2.2
PN-EN 12809:2002 p. A.6.2.3.
PN-EN 12809:2002 p. A.6.2.4
PN-EN 12809:2002 p. A.6.2.6
PN-EN 12809:2002 p. A3.
PN-EN 12815:2004 p. A.1.1; A.4.4.3
PN-EN 12815:2004 p. A.2.3.2; A.4.4.3
PN-EN 12815:2004 p. A.2.3.4.
PN-EN 12815:2004 p. A.2.3; A.4.4.2
PN-EN 12815:2004 p. A.2.5; A.4.5
PN-EN 12815:2004 p. A.4.10
PN-EN 12815:2004 p. A.4.11
PN-EN 12815:2004 p. A.4.17
PN-EN 12815:2004 p. A.4.18
PN-EN 12815:2004 p. A.4.2
PN-EN 12815:2004 p. A.4.4; A.6.2.1.1
PN-EN 12815:2004 p. A.4.4; A.6.2.1.2
PN-EN 12815:2004 p. A.4.5; A.4.9; A.4.12; A.6.2.2
PN-EN 12815:2004 p. A.4.6; A.6.2.1.3
PN-EN 12815:2004 p. A.4.7; A.4.10; A.4.12; A.4.16
PN-EN 12815:2004 p. A.6.2.1
PN-EN 12815:2004 p. A.6.2.2
PN-EN 12815:2004 p. A.6.2.3
PN-EN 12815:2004 p. A.6.2.4
PN-EN 12815:2004 p. A.6.2.6
PN-EN 13229:2002 p. A.4.2
PN-EN 13229:2002 p. A.4.4.2
PN-EN 13229:2002 p. A.4.4.3
PN-EN 13229:2002 p. A.4.5.2
PN-EN 13229:2002 p. A.4.7; A.4.8; A.4.9
PN-EN 13229:2002 p. A.4.9.5
PN-EN 13229:2002 p. A.4.9.6
PN-EN 13229:2002 p. A.6.2.1
PN-EN 13229:2002 p. A.6.2.1.1
PN-EN 13229:2002 p. A.6.2.1.2
PN-EN 13229:2002 p. A.6.2.1.3
PN-EN 13229:2002 p. A.6.2.2
PN-EN 13229:2002 p. A.6.2.3
PN-EN 13229:2002 p. A.6.2.4
PN-EN 13229:2002 p. A.6.2.6
PN-EN 13229:2002 p. A2.3.4;A.4
PN-EN 13240:2008 p. A.4.2
PN-EN 13240:2008 p. A.4.4.2
PN-EN 13240:2008 p. A.4.4.3
PN-EN 13240:2008 p. A.4.5.2
PN-EN 13240:2008 p. A.4.7; A.4.8; A.4.9
PN-EN 13240:2008 p. A.4.9.4
PN-EN 13240:2008 p. A.4.9.5
PN-EN 13240:2008 p. A.6.2.1
PN-EN 13240:2008 p. A.6.2.1.1
PN-EN 13240:2008 p. A.6.2.1.2
PN-EN 13240:2008 p. A.6.2.1.3
PN-EN 13240:2008 p. A.6.2.2
PN-EN 13240:2008 p. A.6.2.3
PN-EN 13240:2008 p. A.6.2.4
PN-EN 13240:2008 p. A.6.2.6
PN-EN 13240:2008 p. A2.3.4; A.4
PN-EN 14785:2009 p. A1.1; A4.4.3
PN-EN 14785:2009 p. A2.2; A4.7; A4.8; A4.9
PN-EN 14785:2009 p. A2.3.2; A4.4.3
PN-EN 14785:2009 p. A2.3.3; 4.4.2
PN-EN 14785:2009 p. A2.3.4; A4
PN-EN 14785:2009 p. A2.5; A4.5
PN-EN 14785:2009 p. A3; A 4.2
PN-EN 14785:2009 p. A4.9.2
PN-EN 14785:2009 p. A4.9.3
PN-EN 14785:2009 p. A6.2.1
PN-EN 14785:2009 p. A6.2.1.1
PN-EN 14785:2009 p. A6.2.1.2
PN-EN 14785:2009 p. A6.2.1.3
PN-EN 14785:2009 p. A6.2.2
PN-EN 14785:2009 p. A6.2.3
PN-EN 14785:2009 p. A6.2.4
PN-EN 14785:2009 p. A6.2.5
PN-EN 14785:2009 p. A6.2.6
PN-EN 15250:2009 A3; A4.2
PN-EN 15250:2009 p. A1.1; A4.4.3
PN-EN 15250:2009 p. A2.2; A4.6; A4.7
PN-EN 15250:2009 p. A2.3.2; A4.4.3
PN-EN 15250:2009 p. A2.3.3; A4.4.2
PN-EN 15250:2009 p. A2.3.4; A4
PN-EN 15250:2009 p. A2.5; A4.6
PN-EN 15250:2009 p. A6.2.1.1
PN-EN 15250:2009 p. A6.2.1.2
PN-EN 15250:2009 p. A6.2.1.3
PN-EN 15250:2009 p. A6.2.1.4
PN-EN 15250:2009 p. A6.2.2
PN-EN 15250:2009 p. A6.2.3
PN-EN 15250:2009 p. A6.2.4
PN-EN 15250:2009 p. A6.2.7
PN-EN 16510-1:2023-06 6.12
PN-EN 16510-1:2023-06 A.4.4.3, A.6.2
PN-EN 16510-1:2023-06 A.4.4.3, A.6.2, 6.2.1
PN-EN 16510-1:2023-06 Załącznik I
PN-EN 16510-1:2023-06 p 5.9.1
PN-EN 16510-1:2023-06 p 6.11
PN-EN 16510-1:2023-06 p A.4.10.2
PN-EN 16510-1:2023-06 p A.4.10.4
PN-EN 16510-1:2023-06 p A.4.10.5
PN-EN 16510-1:2023-06 p A.4.10.7
PN-EN 16510-1:2023-06 p A.4.11.2.1, A.4.11.2.2, A.4.11.2.4, A.4.11.2.5
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6
PN-EN 16510-1:2023-06 p A.6.2.1.5, A.6.2.1.6,
PN-EN 16510-1:2023-06 p. A.2.3.4
PN-EN 16510-1:2023-06 p. A.2.3.4, 6.5
PN-EN 16510-1:2023-06 p. A.4.10.6
PN-EN 16510-1:2023-06 p. A.4.10.7
PN-EN 16510-1:2023-06 p. A.4.4.2, A.
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3
PN-EN 16510-1:2023-06 p. A.4.4.2, A.3, Załącznik F
PN-EN 16510-1:2023-06 p. A.4.4.3
PN-EN 16510-1:2023-06 p. A.4.5.2
PN-EN 16510-1:2023-06 p.A.4.2
PN-EN 16510-1:2023-06 p.A.4.4.2, A.3, Załącznik D, Załącznik E
PN-EN 16510-1:2023-06 p.A.4.4.3
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6 „
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.4, 5.5, 5.6,
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.5
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10, 5.6
PN-EN 16510-1:2023-06 p.A.4.7, A.4.10.4, 5.4, 5.5, 5.6
PN-EN 16510-1:2023-06 p.A.6.2.1
PN-EN 16510-1:2023-06 p.A.6.2.1.
PN-EN 16510-1:2023-06 p.A.6.2.1.2
PN-EN 16510-1:2023-06 p.A.6.2.1.3
PN-EN 16510-1:2023-06 p.A.6.2.1.4
PN-EN 16510-1:2023-06 p.A.6.2.2
PN-EN 16510-1:2023-06 p.A.6.2.3
PN-EN 16510-1:2023-06 p.A.6.2.4
PN-EN 16510-1:2023-06 p.A.6.2.6
PN-EN 16510-2-1:2023-06 p. 4.3 „N“
PN-EN 16510-2-1:2023-06 p. 4.4, 4.5 „N“
PN-EN 16510-2-1:2023-06 p. 4.6 „N“
PN-EN 16510-2-1:2023-06 p. 4.7.2,4.7.3, 4.7.8 „N“
PN-EN 16510-2-1:2023-06 p. 4.7.3, 4.7.4, 4.7.5 „N“
PN-EN 16510-2-1:2023-06 p. 4.7.6, 4.7.7 „N“
PN-EN 16510-2-1:2023-06 p. 4.8.1, 4.8.4 „N“
PN-EN 16510-2-1:2023-06 p. 4.8.2, 4.8.5 „N“
PN-EN 16510-2-1:2023-06 p. 4.8.3, 4.8.6 „N“
PN-EN 16510-2-1:2023-06 p. 4.8.7, 4.8.8 „N“
PN-EN 16510-2-1:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“
PN-EN 16510-2-1:2023-06 p. 5.3 „N“
PN-EN 16510-2-1:2023-06 p. 5.5, 5.6 „N“
PN-EN 16510-2-2:2023-06 p. 4.2 „N“
PN-EN 16510-2-2:2023-06 p. 4.3, 4.4 „N“
PN-EN 16510-2-2:2023-06 p. 4.5 „N“
PN-EN 16510-2-2:2023-06 p. 4.6.2,4.6.3 „N“
PN-EN 16510-2-2:2023-06 p. 4.6.4, 4.6.5„N“
PN-EN 16510-2-2:2023-06 p. 4.6.6, 4.6.7 „N“
PN-EN 16510-2-2:2023-06 p. 4.7.1, 4.7.4 „N“
PN-EN 16510-2-2:2023-06 p. 4.7.2, 4.7.5 „N“
PN-EN 16510-2-2:2023-06 p. 4.7.3, 4.7.6 „N“
PN-EN 16510-2-2:2023-06 p. 4.7.7, 4.7.8 „N“
PN-EN 16510-2-2:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N“
PN-EN 16510-2-2:2023-06 p. 5.3.3 „N“
PN-EN 16510-2-2:2023-06 p. 5.5, 5.6 „N“
PN-EN 16510-2-3:2023-06 A.4.301.1 „N”
PN-EN 16510-2-3:2023-06 A.4.301.2 „N”
PN-EN 16510-2-3:2023-06 A.4.301.3 „N”
PN-EN 16510-2-3:2023-06 p. 4.3, 4.4, „N”
PN-EN 16510-2-3:2023-06 p. 4.5 „N”
PN-EN 16510-2-3:2023-06 p. 4.6.2,4.6.3 „N”
PN-EN 16510-2-3:2023-06 p. 4.6.4, 4.6.5 „N”
PN-EN 16510-2-3:2023-06 p. 4.6.6, 4.6.7 „N”
PN-EN 16510-2-3:2023-06 p. 4.7.1, 4.7.4 „N”
PN-EN 16510-2-3:2023-06 p. 4.7.2, 4.7.5 „N”
PN-EN 16510-2-3:2023-06 p. 4.7.3, 4.7.6 „N”
PN-EN 16510-2-3:2023-06 p. 4.7.7, 4.7.8 „N”
PN-EN 16510-2-3:2023-06 p. 4.7.9, 4.7.10, 4.7.11 „N”
PN-EN 16510-2-3:2023-06 p. 5.5 „N”
PN-EN 16510-2-3:2023-06 p. 5.9 „N”
PN-EN 16510-2-3:2023-06 p.4.1 „N”
PN-EN 16510-2-3:2023-06 p.5.6 „N”
PN-EN 16510-2-5:2025-10 p. 4.3 „N“
PN-EN 16510-2-5:2025-10 p. 4.4, 4.5 „N“
PN-EN 16510-2-5:2025-10 p. 4.6 „N“
PN-EN 16510-2-5:2025-10 p. 4.7.2,4.7.5 „N“
PN-EN 16510-2-5:2025-10 p. 4.7.3, 4.7.4, 4.7.5 „N“
PN-EN 16510-2-5:2025-10 p. 4.7.4 „N“
PN-EN 16510-2-5:2025-10 p. 4.7.5, 5.5, A.4.10 „N“
PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2 „N“
PN-EN 16510-2-5:2025-10 p. 4.8.1, 4.8.4, A.6.2.2, A.6.2.4, A.6.2.501 „N“
PN-EN 16510-2-5:2025-10 p. 4.8.2, 4.8.4, A.6.2.3„N“
PN-EN 16510-2-5:2025-10 p. 4.8.3 „N“
PN-EN 16510-2-5:2025-10 p. 4.8.4, 4.8.5 „N“
PN-EN 16510-2-5:2025-10 p. 4.8.502, A.2.501, A.6.2.502 „N“
PN-EN 16510-2-5:2025-10 p. 4.8.6, 4.8.7 „N“
PN-EN 16510-2-5:2025-10 p. A.6.2.501 „N“
PN-EN 16510-2-5:2025-10 p.A.4.10.2 „N“
PN-EN 16510-2-5:2025-10 p.A.4.10.7 „N“
PN-EN 16510-2-6:2023-06 p 5.1.2, 5.1.3 „N“
PN-EN 16510-2-6:2023-06 p A.4.10.601.1 „N“
PN-EN 16510-2-6:2023-06 p A.4.10.601.1„N“
PN-EN 16510-2-6:2023-06 p A.4.10.601.2 „N“
PN-EN 16510-2-6:2023-06 p A.4.10.601.3 „N“
PN-EN 16510-2-6:2023-06 p. 4.3 „N“
PN-EN 16510-2-6:2023-06 p. 4.4, 4.5 „N“
PN-EN 16510-2-6:2023-06 p. 4.6 „N“
PN-EN 16510-2-6:2023-06 p. 4.7.2,4.7.3 „N“
PN-EN 16510-2-6:2023-06 p. 4.7.4, 4.7.5 „N“
PN-EN 16510-2-6:2023-06 p. 4.7.6, 4.7.7 „N“
PN-EN 16510-2-6:2023-06 p. 4.8.1, 4.8.4 „N“
PN-EN 16510-2-6:2023-06 p. 4.8.2, 4.8.5 „N“
PN-EN 16510-2-6:2023-06 p. 4.8.3, 4.8.6 „N“
PN-EN 16510-2-6:2023-06 p. 4.8.7, 4.8.8 „N“
PN-EN 16510-2-6:2023-06 p. 4.8.9, 4.8.10, 4.8.11 „N“
PN-EN 16510-2-6:2023-06 p. 5.3.3 „N“
PN-EN 16510-2-6:2023-06 p. 5.5.1, 5.5.2, 5.6 „N“
PN-EN 16510-2-7:2025-10 p A.4.10.7.702, A.4.10.7.703 „N“
PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.1, A.4.10.7.703.1.3 „N“
PN-EN 16510-2-7:2025-10 p A.4.10.7.703.1.2 „N“
PN-EN 16510-2-7:2025-10 p. 4.3 „N“
PN-EN 16510-2-7:2025-10 p. 4.4, 4.5 „N“
PN-EN 16510-2-7:2025-10 p. 4.6 „N“
PN-EN 16510-2-7:2025-10 p. 4.7.2, 4.7.3 „N“
PN-EN 16510-2-7:2025-10 p. 4.7.4, 4.7.5„N“
PN-EN 16510-2-7:2025-10 p. 4.7.6, 4.7.7 „N“
PN-EN 16510-2-7:2025-10 p. 4.7.8, A.4.10.4.2. „N“
PN-EN 16510-2-7:2025-10 p. 4.8.10, 4.8.11, 4.8.12 „N“
PN-EN 16510-2-7:2025-10 p. 4.8.2, 4.8.5 „N“
PN-EN 16510-2-7:2025-10 p. 4.8.3, 4.8.6 „N“
PN-EN 16510-2-7:2025-10 p. 4.8.4, 4.8.7 „N“
PN-EN 16510-2-7:2025-10 p. 4.8.8, 4.8.9 „N“
PN-EN 16510-2-7:2025-10 p. 5.5.1, 5.5.3, 5.6 „N“
PN-EN 16510-2-7:2025-10 p. A.4.10.6 „N“
PN-EN 297:2002 p. 4.1.6.7
PN-EN 303-5 +A1:2023-05 p. 5.12
PN-EN 303-5 +A1:2023-05 p. 5.14
PN-EN 303-5 +A1:2023-05 p. 5.16.2
PN-EN 303-5 +A1:2023-05 p. 5.16.3
PN-EN 303-5 +A1:2023-05 p. 5.16.4
PN-EN 303-5 +A1:2023-05 p. 5.16.6, 5.18.1
PN-EN 303-5 +A1:2023-05 p. 5.17
PN-EN 303-5 +A1:2023-05 p. 5.7.4
PN-EN 303-5 +A1:2023-05 p. 5.7.5
PN-EN 303-5+A1:2023-05 p. 5.10
PN-EN 303-5+A1:2023-05 p. 5.11
PN-EN 303-5+A1:2023-05 p. 5.12
PN-EN 303-5+A1:2023-05 p. 5.13
PN-EN 303-5+A1:2023-05 p. 5.15
PN-EN 303-5+A1:2023-05 p. 5.2
PN-EN 303-5+A1:2023-05 p. 5.2, 5.6.2, 5.6.3, 5.7.2, 5,7,3
PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.6.3; 5.8
PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.2; 5.8
PN-EN 303-5+A1:2023-05 p. 5.2; 5.6.3; 5.6.4
PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.3
PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.7.1.1, 5.7.1.2, 5.7.2, 5.7.3, 5.9.1
PN-EN 303-5+A1:2023-05 p. 5.6.1, 5.6.4, 5.9.2
PN-EN 303-5+A1:2023-05 p. 5.6.3
PN-EN 303-5+A1:2023-05 p. 5.7.7
PN-EN 303-5+A1:2023-05 p. 5.9.3
PN-EN 303-5:2012 p. 5.10.3.2
PN-EN 303-5:2012 p. 5.12
PN-EN 303-5:2012 p. 5.13
PN-EN 303-5:2012 p. 5.14
PN-EN 303-5:2012 p. 5.15
PN-EN 303-5:2012 p. 5.2
PN-EN 303-5:2012 p. 5.2, 5.7.3, 5.7.4
PN-EN 303-5:2012 p. 5.2; 5.7.2; 5.7.3; 5.9
PN-EN 303-5:2012 p. 5.6
PN-EN 303-5:2012 p. 5.7.1; 5.7.3
PN-EN 303-5:2012 p. 5.7.3
PN-EN 303-5:2012 p.5.10.3
PN-EN 303-5:2012 p.5.11
PN-EN 303-5:2012 p.5.2; 5.7.2; 5.7.3; 5.8.2
PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.10.2
PN-EN 303-5:2012 p.5.7.1; 5.7.4; 5.8.1.1; 5.8.1.2; 5.8.2; 5.8.3; 5.10.1
PN-EN 303-5:2021-09 p. 5.15
PN-EN 303-5:2021-09 p. 5.16.2
PN-EN 303-5:2021-09 p. 5.16.3
PN-EN 303-5:2021-09 p. 5.16.4
PN-EN 303-5:2021-09 p. 5.16.6, 5.18.1
PN-EN 303-5:2021-09 p. 5.2
PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.6.3; 5.8
PN-EN 303-5:2021-09 p. 5.2; 5.6.2; 5.8
PN-EN 303-5:2021-09 p. 5.2; 5.6.3; 5.6.4
PN-EN 303-5:2021-09 p. 5.6.1; 5.6.3
PN-EN 303-5:2021-09 p. 5.6.3
PN-EN 303-5:2021-09 p. 5.7.7
PN-EN 303-5:2021-09 p. 5.9.3
PN-EN 303-5:2021-09 p.5.10
PN-EN 303-5:2021-09 p.5.11
PN-EN 303-5:2021-09 p.5.12
PN-EN 303-5:2021-09 p.5.13
PN-EN 303-5:2021-09 p.5.2; 5.6.2; 5.6.3; 5.7.2; 5.7.3
PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.7.1.1; 5.7.1.2; 5.7.2; 5.7.3; 5.9.1
PN-EN 303-5:2021-09 p.5.6.1; 5.6.4; 5.9.2
PN-EN 303-5:2021-09 p.5.9.3
PN-EN 304:2017-11 p. 6.15
PN-EN 304:2017-11 p. 6.6
PN-EN 304:2017-11 p. A.8.3
PN-EN 304:2017-11 rys.4,5,6
PN-M-34452:1999 p. 4.3.2
PN-M-34452:1999 p. 4.3.3
PN-M-34452:1999 p. 4.3.6
PN-M-34452:1999 p. 4.3.6.3
PN-M-34452:1999 p. 5.3.7
PN-M-34452:1999 p.4.4.3.1;4.4.3.18;5.3
PN-M–34452:1999 p. 4.2.7
PN-M–34452:1999 p. 4.3.8; 4.4.3.12
PN-M–34452:1999 p. 4.4.3.16
PN-M–34452:1999 p. 4.4.3.3; 5.6.1
PN-M–34452:1999 p. 4.4.3.4; 5.6.2
PN-M–34452:1999 p. 4.4.3.5; 5.6.3
PN-M–34452:1999 p. 4.4.3.6; 5.6.4
PN-M–34452:1999 p. 5.2
PN-M–34452:1999 p. 5.4
Procedura LGP/42/B
Procedura nr LGP/42/B wyd. 4
Zharmonizowane specyfikacje techniczne